Test Spatial CCT and intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Taiwan motor, Angle Coder and Constant Temperature Class A Detector to keep high accuracy. B-Beta & C-Gamma test for all lamps up to 1.6m and 40kg
High precision-rotation-luminaire-goniospectroradiometer世满 江
LSG-1800BCCD Goniospectroradiometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800BCCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
LSG-1800CCD/LSG-1700CCD Goniospectroradiometer is an automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800CCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
LSG-1800/LSG-1700 Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800 is an update version for LSG-1700, the LSG-1800 use a high accuracy Motor and precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
LSG-2000 Goniophotometer with Rotating Mirror also called the Moving Mirror Goniophotometer. The LSG-2000 is an automatic light distribution intensity 3D curve testing system. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
Test intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Japanese motor, Angle Coder and Constant Temperature Class A Detector to keep high accuracy. Both B-Beta & C-Gamma test for all luminaires up to 1.4m and 40kg
LSG-1800/LSG-1700 goniophotometer is high precision automatic goniophotometeric instrument for the luminous intensity distribution measurement with facility for rotating the light source. The LSG-1800 is an update version for LSG-1700.
High precision-rotation-luminaire-goniospectroradiometer世满 江
LSG-1800BCCD Goniospectroradiometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800BCCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
LSG-1800CCD/LSG-1700CCD Goniospectroradiometer is an automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800CCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
LSG-1800/LSG-1700 Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800 is an update version for LSG-1700, the LSG-1800 use a high accuracy Motor and precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
LSG-2000 Goniophotometer with Rotating Mirror also called the Moving Mirror Goniophotometer. The LSG-2000 is an automatic light distribution intensity 3D curve testing system. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
Test intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Japanese motor, Angle Coder and Constant Temperature Class A Detector to keep high accuracy. Both B-Beta & C-Gamma test for all luminaires up to 1.4m and 40kg
LSG-1800/LSG-1700 goniophotometer is high precision automatic goniophotometeric instrument for the luminous intensity distribution measurement with facility for rotating the light source. The LSG-1800 is an update version for LSG-1700.
High precision-rotation-luminaire-goniospectroradiometer世满 江
LSG-1800BCCD goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurement with facility for rotating the light source.
Rotation Luminaire Goniophotometer (Big Size)Lisun Group
Test intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Taiwan motor and Constant Temperature Detector to keep high accuracy. Test all luminaires up to 1.6m and 40kg
LISUN High precision-rotation-luminaire-goniophotometer LSG-1800B世满 江
LSG-1800B Goniophotometer is automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800B use a constant temperature detector, Japanese Motor and Germany precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
LSG-2000 Goniophotometer with Rotating Mirror is also called the Moving Mirror Goniophotometer. It is an automatic light distribution intensity 3D curve testing system.
Lisun Goniospectroradiometer with Moving Mirror can test luminaries rotating in the presscribed burning position and around the vertical axle and a reflecting mirror rotates around the horizontal axle, meanwhile, a synchronous axle will rotate toward the opposite direction synchronously.
LSG-5000 Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
LSG-5000 CCD Moving Detector Goniophotometer is full meet LM-79 Clause 9.3.1 request. The tested lamp will keep burning position and be fixed, near field detector move together with the big mirror in a line, and the far field detector will move with the big mirror synchronously. The detector will always sense the light directly from the luminaries.
Rotation Luminaire Goniophotometer (Big Size)1600BLisun Group
Test intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Taiwan motor and Constant Temperature Detector to keep high accuracy. Test all luminaires up to 1.6m and 40kg
LSG-5000 Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
LSG-1800CCD/LSG-1700CCD goniospectroradiometer is an automatic goniophotometer instrument for luminous intensity distribution measurement with facility for rotating the light source.
It is according to IEC 60929, IEC 60969 and IEC61000-3-2. Up to 1MHz lrms can test every EB and has expanding analysis function for envelope wave. With big LCD can display the test results directly without PC
It is ccording to GB/T 24825-2009 and IEC 62384:2006. It can measure the following parameters: Input Characteristics Test (AC/DC), Output Characteristics Test (AC/DC), Start Characteristics Test (DC) and Hormanic Test.
More Related Content
Similar to Rotation Luminaire Goniospectroradiometer
High precision-rotation-luminaire-goniospectroradiometer世满 江
LSG-1800BCCD goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurement with facility for rotating the light source.
Rotation Luminaire Goniophotometer (Big Size)Lisun Group
Test intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Taiwan motor and Constant Temperature Detector to keep high accuracy. Test all luminaires up to 1.6m and 40kg
LISUN High precision-rotation-luminaire-goniophotometer LSG-1800B世满 江
LSG-1800B Goniophotometer is automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800B use a constant temperature detector, Japanese Motor and Germany precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
LSG-2000 Goniophotometer with Rotating Mirror is also called the Moving Mirror Goniophotometer. It is an automatic light distribution intensity 3D curve testing system.
Lisun Goniospectroradiometer with Moving Mirror can test luminaries rotating in the presscribed burning position and around the vertical axle and a reflecting mirror rotates around the horizontal axle, meanwhile, a synchronous axle will rotate toward the opposite direction synchronously.
LSG-5000 Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
LSG-5000 CCD Moving Detector Goniophotometer is full meet LM-79 Clause 9.3.1 request. The tested lamp will keep burning position and be fixed, near field detector move together with the big mirror in a line, and the far field detector will move with the big mirror synchronously. The detector will always sense the light directly from the luminaries.
Rotation Luminaire Goniophotometer (Big Size)1600BLisun Group
Test intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Taiwan motor and Constant Temperature Detector to keep high accuracy. Test all luminaires up to 1.6m and 40kg
LSG-5000 Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
LSG-1800CCD/LSG-1700CCD goniospectroradiometer is an automatic goniophotometer instrument for luminous intensity distribution measurement with facility for rotating the light source.
Similar to Rotation Luminaire Goniospectroradiometer (20)
It is according to IEC 60929, IEC 60969 and IEC61000-3-2. Up to 1MHz lrms can test every EB and has expanding analysis function for envelope wave. With big LCD can display the test results directly without PC
It is ccording to GB/T 24825-2009 and IEC 62384:2006. It can measure the following parameters: Input Characteristics Test (AC/DC), Output Characteristics Test (AC/DC), Start Characteristics Test (DC) and Hormanic Test.
The chamber fully complies with the requirements of Standard GB/T16585-1996, GB14522-93, GB/T16422.3-97, ASTMG53 and etc., provides the best UV sunlight simulation, and is easy to use and operate.
It is adopts the theory of spectrophotometer. It used for plastic, printing, paint, ink, textile, dyeing and other industries for color management. It measure L*a*b, L*c*h and the sample △E and △Lab value
Test intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Japanese motor, German Angle Coder and Constant Temperature Class L Detector to keep high accuracy. Both B-Beta & C-Gamma test for all luminaires up to 1.4m and 40kg
Full meet LM-79 Clause 9.3.1, GB, CIE & IEC Standards. Test intensity distribution curve in 3D & export IES files for DiaLux. It can test all kinds of luminaires which length up to dia=0.6m and max 20kg
High Precision Goniophotometer for Automotive and Traffic Signal LampsLisun Group
It is a CIE A-α Goniophotometer and full meet GB, ECE, SAE, JIS, KS and FMVSS108. Test intensity distribution curve in 3D & export IES files for DiaLux. The test lamp can be max 35kg
Near Field Moving Detector GoniophotometerLisun Group
The near field moving detector goniophotometer is fully meet LM-79 and need very small dark room size. It tests intensity distribution curve in 3D & export IES files for DiaLux. It can test max size of luminaire up to Φ300mm(diameter)*550mm(height) and 20kg
According to LM-79, GB, CIE & IEC Standards. Test intensity distribution curve in 3D & export IES files for DiaLux. It already combined 1m length dark room and used to test the lamps which diameter is less than 18cm
CCD Detector and spectrum range is 380~780nm. Test lux and all color parameters. The size is compact and applicated with 5inch big LCD Screen, with 4000mAH battery which can work over 20hours.
It is ccording to GB/T 24825-2009 and IEC 62384:2006. It can measure the following parameters for 60 LED Drivers at one time in production line quick in 20s: Input Characteristics Test (AC), Output Characteristics Test (AC/DC) and harmonic
According to IESNA LM-80-2008, LM-82 and TM-21, it will record the lumen for L70, L50 and L30, the software is based on Arrhenius model to calculate the LED life
HSCD-750 adopts the geometric of D/11 lighting. It can be used for color matching for many industries and widely used in painting industry, textile industry, plastic industry, food industry, and other industries for quality control
According to IEC61000-4-5, EN61000-4-12, ANSI C62.41.1/2-2002 and GB/T17626.5,12. Combined SG61000-5 Surge Generator and RWG61000-12 Ring Wave Generator, the system already built-in single phase CDN.
Includes EMI Receiver, Artificial Network, CDN23, Isolation Transformers, Attenuator and Coaxial Cable. Frequency is 9K~300MHZ, measure PK,QP and AV range from 20dBμV to 140dBμV, test tolerance is 2dB
DSCD-900 adopts the geometric of D/8, built-in full wavelength of LED, double beam optical system, ETC every-time calibration technology, spectral reflectance standard deviation within 0.08, max ΔE*ab is 0.03
It used in different industries suchas plastic cement, printing, paint, weaving and dyeing. It measures the sample color data L*a*b*, L*c*h*, colordifference ΔE and ΔLab according to CIE colorspace.
Forklift Classes Overview by Intella PartsIntella Parts
Discover the different forklift classes and their specific applications. Learn how to choose the right forklift for your needs to ensure safety, efficiency, and compliance in your operations.
For more technical information, visit our website https://intellaparts.com
Final project report on grocery store management system..pdfKamal Acharya
In today’s fast-changing business environment, it’s extremely important to be able to respond to client needs in the most effective and timely manner. If your customers wish to see your business online and have instant access to your products or services.
Online Grocery Store is an e-commerce website, which retails various grocery products. This project allows viewing various products available enables registered users to purchase desired products instantly using Paytm, UPI payment processor (Instant Pay) and also can place order by using Cash on Delivery (Pay Later) option. This project provides an easy access to Administrators and Managers to view orders placed using Pay Later and Instant Pay options.
In order to develop an e-commerce website, a number of Technologies must be studied and understood. These include multi-tiered architecture, server and client-side scripting techniques, implementation technologies, programming language (such as PHP, HTML, CSS, JavaScript) and MySQL relational databases. This is a project with the objective to develop a basic website where a consumer is provided with a shopping cart website and also to know about the technologies used to develop such a website.
This document will discuss each of the underlying technologies to create and implement an e- commerce website.
Student information management system project report ii.pdfKamal Acharya
Our project explains about the student management. This project mainly explains the various actions related to student details. This project shows some ease in adding, editing and deleting the student details. It also provides a less time consuming process for viewing, adding, editing and deleting the marks of the students.
Sachpazis:Terzaghi Bearing Capacity Estimation in simple terms with Calculati...Dr.Costas Sachpazis
Terzaghi's soil bearing capacity theory, developed by Karl Terzaghi, is a fundamental principle in geotechnical engineering used to determine the bearing capacity of shallow foundations. This theory provides a method to calculate the ultimate bearing capacity of soil, which is the maximum load per unit area that the soil can support without undergoing shear failure. The Calculation HTML Code included.
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.
(C) 2024 Robbie E. Sayers
Saudi Arabia stands as a titan in the global energy landscape, renowned for its abundant oil and gas resources. It's the largest exporter of petroleum and holds some of the world's most significant reserves. Let's delve into the top 10 oil and gas projects shaping Saudi Arabia's energy future in 2024.
1. High Precision
Rotation Luminaire Goniospectroradiometer
(LSG-1700BCCD/LSG-1800BCCD)
Brochure
Global Office of Lisun Electronics Inc.
http://www.Lisungroup.com
Lisun Group (Hong Kong) Limited
Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon,
Hong Kong
Tel: 00852-68852050 Fax: 00852-30785638
Email: SalesHK@Lisungroup.com
Lisun Electronics (Shanghai) Co., Ltd
Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading
District, Shanghai, 201802, China
Tel: +86(21)5108 3341 Fax: +86(21)5108 3342
Email: SalesSH@Lisungroup.com
Lisun Sales Rep Office (USA)
Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A.
Email: Sales@Lisungroup.com
Lisun China Factory
Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China
Tel: +86-189-1799-6096
Email: Engineering@Lisungroup.com
Lead in CFL & LED Test Instruments
2. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 1 -
1. System Configuration
A. Goniophotometric System:
Goniometric Rotating Console:
1) LSG-1800XCCD/LSG-1800BCCD: Japanese Mitsubishi Motor and
German Angle encoder System to keep the test accuracy to
0.1degree
2) LSG-1700BCCD: Taiwan produced Motor and Angle encoder System
to keep the test accuracy to 0.2degree
LSG-1800XCCD/LSG-1800BCCD has Goniometric Rotating Control
Instrument in 19inch cabinet: It connects to the PC and was controlled
by the software.
LSG-1800XCCD/LSG-1800BCCD has Goniometric Rotating Control
Instrument in dark room: This can allow the customer to control the
rotating in the dark room when install the lumainires but no need to
control in the PC.
Double Channel & High Precision Photometer
Class A Constant Temperature Photo Detector (Option is Class L)
Cross-beam Laser System for Calibrating
English Measuring Software
Two sets of luminaries Clamps: multi-functions
Oversea Delivery and Packing: all of the instruments and accessories will
be packed with Fumigation free three plywood, include the delivery cost
to Shanghai sea port
B. SLS-100W DC Standard Light Intensity Lamp
C. Digital Power Meter:
1) LSG-1800XCCD/LSG-1800BCCD has LS2010 Digital Power Meter:
High Accuracy to measure AC voltage, current, power and PF, also
measure harmonic.
2) LSG-1700BCCD has LS2012 Digital Power Meter: Accuracy to
measure AC and DC voltage, current, power and PF
D. DC3010 CC & CV DC Power Source: DC3010 output is 30V/10A, Option can
be DC6010 (output is 60V/10A) and DC12010 (output is 120V/10A)
E. AC Power Source:
1) LSG-1800XCCD/LSG-1800BCCD has LSP-1KVAS AC Power Source
2) LSG-1700BCCD has LSP-500VAS AC Power Source
F. CASE-19IN 19inch Standard Instruments Cabinet
G. LMS-9000B High Precision CCD Spectraidomeeter
H. CLAMP-9000 Accessories and Adjustable Tripod for LMS-9000B
3. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 2 -
Full View for High Precision Rotation Luminaire Goniospectroadiometer
Note: PC and Printer prepared by the customer (request at least two USB ports)
2. Working Principle
Goniophotometric System carries out measuring methods of fixed location and
rotating luminaires. The measured luminaire is installed on the rotating supporte,
the center of which is in line with the rotating supporter center with the help of Laser
sight. The fixed photometry detector is testing the luminous intensity in various
horizontal directions, while the light source rotating. The mechanical equipment
allows turning the tested luminaires around a vertical axis and a horizontal axis.
When tested luminaires turn around horizontal axis, the detector which is at the
same level with rotating table will measure the intensity of each direction at this
surface. When rotating with vertical axis, the detector will measure the intensity at
the vertical surface. The vertical and horizontal axis can be rotated continuously at
-180°~ +180°. According to the measurement requirements, the system can be
operated in B-β, A-α and C-γ coordinates. When getting intensity distribution data,
computer will calculate other photometric parameters automatically.
Double pillars structure (B-β coordinate system)
This type is applied to fixed grille lamp. The symmetry axis of lamp and the
horizontal of rotating supporter is coaxial, in the B-β coordinate system, and the
two is vertical Cross, in the A-α coordinate system.
High Precision CCD Spectroradiometer with fixture set
4. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 3 -
Single pillar structure (C-γcoordinate and Conic coordinate)
The single column structure will be gotten when the assistant column is taken down
from double columns structure. This type is applied to fixed tube lamp, spot lamp
etc. The axis radiation of lamp and the horizontal of rotating supporter is coaxial.
3. System Functions
LSG-1800BCCD/LSG-1700BCCD Goniospectroradiometer is high precision
automatic goniophotometric instrument for luminous intensity distribution
measurements with facility for turning the light source. The LSG series can do the
spatial CCT test when do the intensity distribution test. It is for industrial laboratory
measurements the photometric data of luminaires.
Be utilized to measure photometric parameters of luminaires for LED road lighting
fixture, room lighting fixture and projecting lighting fixture, such as spatial intensity
distribution curve, spatial iso-intensity curve, intensity distribution curve on each
section (represent by right-angled coordinates or polar coordinates, luminance
limitation curve, luminaire efficiency, glare grade, effective beam angle, upward
luminous flux ratio, downward luminous flux ratio, total luminous flux, effective
luminous flux, utilization factor and electric parameters voltage, current, wattage,
power factor and etc. The measured data meets IES standard format and can be
applied for lighting design by lighting design software. The measurement system
fully satisfies the requirement of lighting design work.
5. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 4 -
4. Specifications
Meets the requirements of CIE, IEC, IES LM-79 & GB standards
The Goniospectroradiometer system=Goniophotometer+Spectroradiometer
Integrating Sphere system
The tested luminaries rotates around an angle of (γ)±180°(or 0-360°) and the
tested luminaries rotates around itself with an angle of (C)±180°(or 0-360°)
Luminosity Testing Range: Illuminance 0.001lx~99,999lx; Light Intensity
1.0cd~107
cd(detector)
The accuracy of angle: 0.1°(LSG-1800XCCD/LSG-1800BCCD) and
0.2°(LSG-1700BCCD)
Work with high accuracy and quick CCD Spectroradiometer to measure spatial
color parameters.
Accuracy of chromaticity coordinate: ±0.0015 or ±0.0005(under standard A
lamp)
Spectral Range Wavelength: 380nm ~780nm; Accuracy of wavelength:
±0.5nm
Accuracy of photometry: CIE Class A (Class L is for option)
Testing Accuracy: 2%(Under Standard Lamp); Stray Light: less than 0.1%
English Version software can run in Win7, Win8 or Win10.
6. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 5 -
5. Laboratory Requirements
Room Requirements according to CIE
Model Dark Room (W*H*L) Operation Room(W*L)
LSG-1800XCCD 4*4*15~30m 3*3m
LSG-1800BCCD 4*2.5*8~30m 3*3m
LSG-1700BCCD 3*2.5*8~30m 3*3m
The wall, ceiling and floor should be all coated with dull black paint or be
covered by black cloth and black carpet.
Air-conditioner should be set in the dark room to control the temperature
around lamps to the standard value upon the CIE requirements
LISUN engineer dept will submit the Lab Design support documents according
to the customer’s lab size after the formal purchase order was confirmed
Model Number
The max size for the Testing Lamp(Unit: mm)
Max
WeightC-Gamma Test with one Pillar
B-Beta Test with two
Pillars
LSG-1800XCCD ∅2500×550(Diameter*Depth) 700*600(Length*Width) 60kg
LSG-1800BCCD ∅1600×550(Diameter*Depth) 700*600(Length*Width) 50kg
LSG-1700BCCD ∅1600×550(Diameter*Depth) 700*600(Length*Width) 40kg
7. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 6 -
6. Typical oversea market customers:
---------------------------------------------------------------------------------------------------
There are many world famous companies and lab institute choose Lisun
Goniophtometer, Please get the reference customers’ information from Lisun Group
Oversea Sales Dept.
7. Design Standard of Device
The construction, technical parameter, test & operate steps as well as data
processing software of Goniospectroradiometer meet the following requirements:
3.1 CIE Pub. NO.70,”The Measurement of Absolute Luminous Intensity
Distributions”
3.2 CIE DIV.Ⅱ-TC10,”Photometry of Luminaires”
3.3 IES LM-35-1989,”IES Approved Method for Photometric Testing of
Floodlights”
3.4 IES LM-31,”IES Approved Method for Photometric Testing of Roadway
Luminaires”
3.5 IES-LM-79, “Electrical and Photometric Measurements of Solid-State Lighting”
3.6 GB/T 7002-1986,“Luminosity Test of Flood Luminaires”
3.7 GB/T 9467-1988, “Luminosity Test of Indoor Luminaires”
3.8 GB/T 9468-1988, “Luminosity Test of Street Luminaires”
3.9 IES 61341 “Method of Measurement of Center Beam Intensity and Beam
Angle(s) of Reflector Lamp”
3.10 CIE Pub.NO.76, “Photometry-the CIE System of Physical Photometry”
8. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 7 -
8. Application Software
All control of the Goniospectroradiometer operations can be realized by the software,
including gonophotometer movement, data acquisition and processing, real-time
display on screen, report print and etc, thus enabling the measurement easy and
secure.
This system can export data files as following formats:
This kind of format files can be transferred by other illumination and luminaire
design software such as DiaLux
Application software can also implement essential calculation for lighting design as
iso-illuminance distribution curve on a working plane, luminance limitation curve,
luminaire efficiency, effective beam angle, upward luminous flux ratio, downward
luminous flux ratio, effective luminous flux, utilization factor curve etc.
The Next Page is the Test Report by software
9. Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 1 of 27 Pages
Report No.: LS1711 Test Time: 8/28/2017 17:02
Luminaire Property
Luminaire Manufacturer: LISUN
Luminaire Category: LED Philips 112 Luminaire Description: LS-71-83-8077
Lamp Catalog: LUMINUS Lamp Description: LUMINUS001
Number of Lamps: 1 Lumens per Lamp: 550
Luminous Length (mm): 50 Luminous Width (mm): 50
Luminous Height (mm): 100 Voltage: 119.9 V
Current: 0.530 A Power: 63.55 W
Power Factor: 0.999
Photometric Results
CIE Class: Direct Total Rated Lamp Lumens: 550.0 lm
Measurement Flux: 539.5 lm Efficiency: 98.08%
Downward Ratio: 98.08% Upward Ratio: 0.00%
Horizontal Diffuse Angle(50%): H99.2
Vertical Diffuse Angle(50%): V101.5
Luminaire Efficacy Rating (LER): 8.54 Central Intensity: 417.76 cd/klm
Max. Intensity: 429.28 cd/klm Pos of Max. Intensity: H45 V8
S/MH(C0/C180): 1.14 S/MH(C90/C270): 1.13
Picture Of Luminaire Luminous Intensity Distribution Curve
0
180
9090
1010
170170
2020
160160
3030
150150
4040
140140
5050
130130
6060
120120
7070
110110
8080
100100
536
429
321
214
107
Average Diffuse Angle(50%): 100.1°
C0-C180 C90-C270
Unit: cd/klm
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-1800BCCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
10. Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 2 of 27 Pages
Luminous Intensity Distribution Curve
0
180
9090
1010
170170
2020
160160
3030
150150
4040
140140
5050
130130
6060
120120
7070
110110
8080
100100
536
429
321
214
107
-180 -120 -60 0 60 120 180
0
107
214
321
429
536
C0-C180 C90-C270 Unit: cd/klm
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-1800BCCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
11. Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 3 of 27 Pages
Luminous Intensity Distribution Curve(cd/klm)
0
180
9090
1010
170170
2020
160160
3030
150150
4040
140140
5050
130130
6060
120120
7070
110110
8080
100100
536
429
321
214
107
cd/klm
C0-C180
C90-C270
η=98.08%
LUMINUS/LUMINUS001
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-1800BCCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
32. Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 24 of 27 Pages
Color Properties
Average Color Nonuniformity:∆u'=-0.2642,∆v'=-0.5294,∆u'v'=0.591689
Maximum Color Nonuniformity:∆u'=-0.0004,∆v'=0.0002,∆u'v'=0.000418
Average Color(u',v'):(0.2643,0.5294)Color Distribution Datas: (u',v')
GC 0.0 90.0 180.0 270.0
0.0 0.2642,0.5294 0.2642,0.5294 0.2642,0.5294 0.2642,0.5294
30.0 0.2644,0.5294 0.2639,0.5296 0.2643,0.5294 0.2646,0.5293
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-1800BCCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector: