1. Brochure
Global Office of Lisun Electronics Inc.
http://www.Lisungroup.com
Lisun Group (Hong Kong) Limited
Add: Room 803, Chevalier House, 45-51 Chatham Road South, Tsim Sha Tsui, KL, HK
Tel: 00852-68852050 Fax: 00852-30785638
Email: SalesHK@Lisungroup.com
Lisun Electronics (Shanghai) Co., Ltd
Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading
District, Shanghai, 201802, China
Tel: +86(21)5108 3341 Fax: +86(21)5108 3342
Email: SalesSH@Lisungroup.com
Lisun Electronics Inc. (USA)
Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A.
Email: Sales@Lisungroup.com
Lisun China Factory
Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China
Tel: +86-189-1799-6096
Email: Engineering@Lisungroup.com
Leader in Lighting & Electrical Test Instruments
Rev. 10/18/2019
CCD Spectroradiometer Integrating
Sphere Compact System for LED
(LPCE-3)
2. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 1 -
CONTENT TABLE
Name Model
Remark Pag
e
CCD Spectroradiometer LMS-7000VIS 350nm~950nm -----2
Optical Fiber CFO-1.5M
Option is CFO-1.5MY for
two integrating spheres
-----3
Digital DC Power Supply DC3005S
30V/5A and communicate
with PC
-----3
Digital Power Meter LS2008R
Option is LS2012 or
LS2010
-----4
AC Power Source LSP-500VAS Option is LPS-1KVAS -----4
Big Integrating Sphere with Cabinet IS-1.5MA-CASE Option is Dia 1.75m or 2m -----5
Small Integrating Sphere IS-0.3M Option is Dia 0.5m -----5
Standard Lamp Source SLS-50W
24V/50W to calibrate big
integrating sphere
-----6
Auxiliary Lamp Test Set RLS-50W
To correct lumen due to
the self absorption issue
-----6
Standard Lamp Source SLS-10W
12V/10W to calibrate for
small integrating sphere
-----6
LM-79 LED Colorimetric, Photometric and Electrical Test Report
Note the following: If you need to test the single LED or LED Chip, you
should choose the items which marked by Blue
3. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 2 -
1、 CCD Spectroradiometer (LMS-7000VIS)
The LMS-7000 work with LISUN A molding integrating sphere to be an ALL-IN-ONE
system to test single LED and LED luminaires photometric, colorimetric and
electrical parameters. The test speed is quick and test results are very accuracy. It
is fully meet CIE127-1997, IES LM-79-08 and IES LM-80-08. The LMS-7000 is a
cost-efficient CCD Spectroradiometer which was widely used by the LED
manufactory.
The LMS-7000 is quick and high accuracy testing. It has been certificated by the
third CNAS lab, the test results can be traced to NIM and NIST.
Specifications:
• Spectrum senors: SMA905 optical fiber
• Spectral Resolution: ±0.2nm
• Reproducibility: ±0.5nm
• Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.003
• Correlated Color Temperature CCT: 1, 500K ~ 25, 000K (±3%)
• High spectral resolution, High sensitivity and excellent reliability
• Communicate PC via USB, the software can be run-in Win7, Win8 and Win10
LMS-7000UV LMS-7000UV-VIS LMS-7000VIS LMS-7000VIS-NIR LMS-7000UV-VIS-NIR
200~400nm 200~800nm 350~950nm 380~1050nm 200~1050nm
4. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 3 -
2、 Optical Fiber (CFO-1.5M)
CFO-1.5M is 1.5m length optical fiber used to connect the spectroradiometer
and integrating sphere. CFO-1.5MY is Y type optical fiber which can connect with
two integrating spheres at the same time.
3、 Digital DC Power Supply (DC3005S)
The DC Series Power Supplies are with high stability and high accuracy. The voltage
and current can be adjustable and simple operation. They are suitable to supply DC
Power for the standard lamps.
Specifications:
• Communicate with PC via software, the Voltage & Current set by the software and
Power Output can be remote controlled.
• Output voltage range: 0.005~30.00V
• Output current range: 0.005~5.000A
• Digital control for Constant Current output or Constant Voltage output
5. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 4 -
4、 Digital Power Meter (LS2008R)
• Measure Voltage, Current, Power and Power Factor (AC model).
• Voltage range: 10~600V; Current range: 0.005~20A
• Accuracy: ± (0.4%reading + 0.1%range + 1digit)
• Communicate with PC via software
5、 AC Power Source (LSP-500VAS)
• AC-DC-AC frequency conversion technology, Controlled & tested by 16 bits MCU
• Protection for over hot, thundering voltage and current
• Total voltage distortion: ≤0.6%; Voltage stability: ≤0.1%/30min
• Load adjust rate: ≤0.1%; Frequency stability: ≤0.05%/30min
• Output voltage range: AC 0.0~300.0V, Output Frequency Range: 45~70Hz,
100Hz, 200Hz and 400Hz
• Power output: LSP-500VAS: 0~150V is 4.2A and 150~300V is 2.1A. LSP-1KVAS:
0~150V is 8.4A and 150~300V is 4.2A.
• Input Power: 220V and 50/60Hz
Model Measure Remark
LS2008R AC Parameters: U, I, P, PF
LS2010 AC Parameters: U, I, P, PF and
harmonic
Special Software can show harmonic
in Win7 or Win8
LS2012 AC+DC Parameters: U, I, P, PF DC: 1~600V, DC Current Range:
0.005~20A (small
current 0.005~2A optional), out of
limit alarming
6. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 5 -
• Communicate with PC via software, the Voltage & Current set by the software and
Power Output can be remote controlled.
6、 Integrating Sphere with Cabinet (IS-1.5MA-CASE)
Due to the LED luminaries such as LED street luminaries developed, to do 4π
geometry testing, it is hard to be hold in the traditional integrating sphere design.
To solve this problem, LISUN design a new kind of sphere.
A Molding Integrating Sphere VS the traditional Integrating Sphere
LISUN new Integrating sphere has the following advantages:
The hold base can bear max 20kg, it can test all kinds of luminaires and light
source such as E27/E40, all tubes such as T5/T8/T12 and all kinds of luminaries
The hold base can be installed in the ceiling or down, height can be adjustable
The test hold base has four power cables connect to the outside Power Supply
and max is 5KW
Build-in Cross laser system which help to install the standard lamp and testing
lamp in the center of the integrating sphere
Build-in Cross Laser System
7. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 6 -
Specification:
Diameter: 0.3m, 0.5m, 1.0m, 1.5m, 1.75m, 2.0m, 2.5m and 3.0m
The painting of integrating spheres is according to CIE Pub.No.84(1989)
BaSO4 coating: ρ(λ)≥0.96(450nm~800nm) and ρ(λ)≥0.92(380nm~450nm)
Fine diffuse reflection: Reflectanceρ ≈0.8 and accuracy of ρ(λ)<1.5%
IS-1.5MA-CASE (1.5m), IS-1.75MA-CASE (1.75m) and IS-2.0MA-CASE (2m)
integrating sphere has built-in cabinet inside to combine all of the instruments.
P.S. The big sphere already includes the Auxiliary lamp position which
allowed to work with the auxiliary lamp to do self-absorption revise, and
also include the cross laser system to help install the lamp in the sphere.
7、 Standard Lamp Source
OSRAM Standard Lamp to calibrate the
spectrum and luminous flux with Lisun Lab
certification. The data can be traced NIM. The
Standard Lamp Source is used to calibrate
the integrating sphere system. The different
size of Integrating Sphere should choose the
right power of standard lamp source
Integrating
Sphere Size
Standard Lamp
Source
0.3m/0.5m SLS-10W
1m/1.5m/1.75m SLS-50W
2m/2.5m/3m SLS-100W
8、 Auxiliary Lamp (RLS-50W)
Due to the luminaires material has self-absorption, the test flux will be a bit
difference than the original flux when test the luminaires in the integrating sphere,
according to CIE request, it is necessary use an Auxiliary lamp to do flux
self-absorption revise.
The next pages are LPCE-3 Test Report.