SlideShare a Scribd company logo
Moving Detector
Goniophotometer
(LSG-3000)
Brochure
Global Office of Lisun Electronics Inc.
http://www.Lisungroup.com
Lisun Group (Hong Kong) Limited
Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon,
Hong Kong
Tel: 00852-68852050 Fax: 00852-30785638
Email: SalesHK@Lisungroup.com
Lisun Electronics (Shanghai) Co., Ltd
Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading
District, Shanghai, 201802, China
Tel: +86(21)5108 3341 Fax: +86(21)5108 3342
Email: SalesSH@Lisungroup.com
Lisun Sales Rep Office (USA)
Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A.
Email: Sales@Lisungroup.com
Lisun China Factory
Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China
Tel: +86-189-1799-6096
Email: Engineering@Lisungroup.com
Lead in CFL & LED Test Instruments
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 1 -
1. System Configuration
A. LSG-3000 Goniophotometric System:
 Goniometric Rotating Console: Famous brand Motor and Angle encoder
System to keep the test accuracy. Both Far Field and Near Field Test.
 High Reflective Moving Mirror: Special design and produced to keep high
reflective value.
 Class A Constant Temperature Photo Detector
 Cross-beam Laser System for Calibrating
 English Measuring Software
 Two sets of luminaries Clamps: multi-functions
 Oversea Delivery and Packing: all of the instruments and accessories will
be packed with Fumigation free three plywood, include the delivery cost
to Shanghai sea port
B. SLS-100W DC Standard Light Intensity Lamp
C. LS2012 Digital Power Meter: High Accuracy to measure AC and DC voltage,
current, power and power factor, also measure harmonic
D. DC3005 CC & CV DC Power Source: DC3005output is 30V/5A. Option can
be DC6010 (output is 60V/10A) and DC12005 (output is 120V/5A)
E. LSP-500VAS AC Power Source: 500VA AC Power Source
F. CASE-19IN 19inch Standard Instruments Cabinet.
Full View for LSG-3000 Moving Detector Goniophotometer
Note: PC and Printer prepared by the customer (request at least three USB ports)
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 2 -
2. Measurement Principle
LSG-3000 Moving Detector Goniophotometer is full meet LM-79 Clause 9.3.1
request. The tested lamp will keep burning position and be fixed, near field detector
move together with the big mirror in a line, and the far field detector will move with
the big mirror synchronously. The detector will always sense the light directly from
the luminaries.
The rotation priority is determined by the software. If mirror axle is took precedence
of rotation, the goniophotometer will continuously measure the luminous intensity
at each γ angle on a vertical plane determined by the C angle, the measuring trace
is equivalent to the longitude. Similarly, while the luminaries axle is priority, the
system will continuously measure the luminous intensity at each C angle on a
conical surface determined by the γ angle, the trace can be looked upon the woof.
See the following figure.
Measurement Principle
3. System Functions
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 3 -
LSG-3000 Moving Detector Goniophotometer
The LSG-3000 full meet LM-79 Clause 9.3.1, CIE and GB standards for
Goniophotometric of luminaries, this system is used to measure spatial luminous
intensity distribution of luminaries for floodlight, street lighting and interior lighting,
and other photometric parameters such as spatial iso-intensity curve, intensity
distribution curve of each section (shown in rectangular coordinate system or polar
coordinate system), iso-illuminance distribution curve, luminance limitation curve,
luminaries efficiency, glare grade, effective beam angles, upward luminous flux ratio,
downward luminous flux ratio, total luminous flux, effective luminous flux,
utilization factor and electric parameters (wattage, power factor, voltage and
current) of luminaries etc. The measured data may be saved in formats IES, LDT
(Eulumdat), CIB, TM4, CIE, CEN and CSV for application software of lighting
calculation and reflector design.
LSG-3000 Can test all of the above luminaires
4. Specifications
1) The mirror rotates around the tested luminaire with an angle of (γ)±180°
and the tested luminaire rotates around itself with an angle of (C)±180°
2) The accuracy of angle: 0.1° Resolution of angle: 0.01°
3) Luminosity Testing Range: Illuminance 0.001lx~99,999lx; Light Intensity
1.0cd~107
cd(detector)
4) Accuracy of photometry: CIE Class A or Class L (option)
5) Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1%
6) English version software can run in Win7, Win8 or Win10
Model Number LSG-3000A LSG-3000B
Measure Size (mm) Diameter=600 Diameter=1000
Measure Weight (Kg) 20 30
Measure Power(W) 600V/10A, AC/DC 600V/10A, AC/DC
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 4 -
5. Laboratory Requirements
1) Room Requirements according to CIE
A. Dark Room: 3*3*8~30m (W*H*L)
B. Operating Room: 3*3m (W*L)
 The dark room wall, ceiling and floor should be all coated with dull black paint or
be covered by black cloth and black carpet.
 Air-conditioner: be set in the dark room to control the temperature around
lamps to the standard value upon the CIE requirements.
Note: LISUN GROUP engineer dept will submit the Lab Design support documents
according to the customer’s real lab size after the formal purchase order was
confirmed
2) Requirements of Eliminating the stray Light
Luminaires must be where the photodetector can only receive the light
reflected by the two moving mirror in the LSG-3000 system. The light given
off directly by the luminaries and reflected by the wall and floor is warded
off by the light fence. Internal surface of the dark room and dark path
together with the surface of the light fence should be painted unpolished
black or be covered by black cloth and black carpet.
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 5 -
3) Temperature of the Environment
Temperature around the lamp or luminaries must be 25℃±1℃ during the test.
Exceptions can be given according to relative lamps as following.
a. Tungsten Incandescent Lamp: 25℃±5℃
b. Double-caps Fluorescent Lamp: 25℃±1℃
c. High Pressure Mercury Lamp: 25℃±2℃
d. Metal Halogen Lamp: 25℃±2℃
e. High Pressure Sodium Lamp: 25℃±2℃
f. Low Pressure Sodium Lamp: 25℃±2
4) Airflow
Airflow may be induced by natural aeration, air conditioner or movement of the
luminaries in the goniophotometer, but the speed of the airflow couldn’t
exceed 0.2m/s.
5) Vibration and shock
When the lamp is in lighting, the vibration couldn’t exceed 10m/s2(4 ~
3000Hz), or the moving scope of the lamp couldn’t exceed 30mm (at most
4Hz)
6) Smoke, Dust and Moisture
The test environment must free from smoke, dust or moisture. At the same
time, even not during the measurement, smoke, dust or moisture will also
influence the reflectance of the reflecting mirror and induce more stray light.
So, the test room must be kept clean, no smoke and dry. The humidity should
be less than 60% RH.
6. Service
1) Installation and Training
LISUN GROUP engineers will take responsibility for installation and Training of
the system at the customer’s
2) Period of Guarantee: 24 months
The service is for free except technician’s travel payment if the service
provided by LISUN GROUP implement at the customer’s.
3) Upgrading the applications software for free
7. Design Standard of Device
The construction, technical parameter, test & operate steps as well as data
processing software of LSG-3000 Moving Detector Goniophotometer meet the
following requirements:
3.1 CIE Pub. NO.70,”The Measurement of Absolute Luminous Intensity
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 6 -
Distributions”
3.2 CIE DIV.Ⅱ-TC10,”Photometry of Luminaires”
3.3 IES LM-35-1989,”IES Approved Method for Photometric Testing of
Floodlights”
3.4 IES LM-31,”IES Approved Method for Photometric Testing of Roadway
Luminaires”
3.5 IES-LM-79, “Electrical & Photometric Measurements of Solid-State Lighting Products”
3.6 GB/T 7002-1986,“Luminosity Test of Flood Luminaires”
3.7 GB/T 9467-1988, “Luminosity Test of Indoor Luminaires”
3.8 GB/T 9468-1988, “Luminosity Test of Street Luminaires”
3.9 IES 61341 “Method of Measurement of Center Beam Intensity and Beam
Angle(s) of Reflector Lamp”
3.10 CIE Pub.NO.76, “Photometry-the CIE System of Physical Photometry”
8. Typical oversea market customers:
-----------------------------------------------------------
There are many world famous company and lab institute choose Lisun
Goniophtometer, Please get the reference customers’ information from Lisun
Group Oversea Sales Dept.
9. Application Software
This system can export data files as following formats:
This kind of format files can be transferred by other illumination and luminaire
design software such as DiaLux
Application software can also implement essential calculation for lighting design as
iso-illuminance distribution curve on a working plane, luminance limitation curve,
luminaire efficiency, effective beam angle, upward luminous flux ratio, downward
luminous flux ratio, effective luminous flux, utilization factor curve etc.
Moving Detector
Goniospectroradiometer
(LSG-3000CCD)
Brochure
Global Office of Lisun Electronics Inc.
http://www.Lisungroup.com
Lisun Group (Hong Kong) Limited
Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon,
Hong Kong
Tel: 00852-68852050 Fax: 00852-30785638
Email: SalesHK@Lisungroup.com
Lisun Electronics (Shanghai) Co., Ltd
Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading
District, Shanghai, 201802, China
Tel: +86(21)5108 3341 Fax: +86(21)5108 3342
Email: SalesSH@Lisungroup.com
Lisun Sales Rep Office (USA)
Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A.
Email: Sales@Lisungroup.com
Lisun China Factory
Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China
Tel: +86-189-1799-6096
Email: Engineering@Lisungroup.com
Lead in CFL & LED Test Instruments
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 1 -
1. System Configuration
A. LSG-3000CCD Goniophotometric System:
 Goniometric Rotating Console: Famous brand Motor and Angle encoder
System to keep the test accuracy. Both Far Field and Near Field Test.
 High Reflective Moving Mirror: Special design and produced to keep high
reflective value.
 Class A Constant Temperature Photo Detector
 Cross-beam Laser System for Calibrating
 English Measuring Software
 Two sets of luminaries Clamps: multi-functions
 Oversea Delivery and Packing: all of the instruments and accessories will
be packed with Fumigation free three plywood, include the delivery cost
to Shanghai sea port
B. SLS-100W DC Standard Light Intensity Lamp
C. LS2012Digital Power Meter: High Accuracy to measure AC and DC voltage,
current, power and power factor, also measure harmonic
D. DC3005 CC & CV DC Power Source: DC3005output is 30V/5A, Option can
be DC6010 (output is 60V/10A) and DC12010 (output is 120V/10A)
E. LSP-500VAS AC Power Source: 500VA AC Power Source
F. CASE-19IN 19inch Standard Instruments Cabinet.
G. High Precision CCD Spectraidomeeter
H. Accessories and Adjustable Tripod for Spectraidomeeter
Full View for LSG-3000CCD Moving Detector Goniospectroradiometer
Note: PC and Printer prepared by the customer (request at least three USB ports)
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 2 -
2. Measurement Principle
LSG-3000CCD Moving Detector Goniospectroradiometer fully meets LM-79 Clause
9.3.1 request. The tested lamp will keep burning position and be fixed, near field
detector move together with the big mirror in a line, and the far field detector will
move with the big mirror synchronously. The detector will always sense the light
directly from the luminaries.
The rotation priority is determined by the software. If mirror axle is took precedence
of rotation, the goniospectroradiometer will continuously measure the luminous
intensity at each γ angle on a vertical plane determined by the C angle, the
measuring trace is equivalent to the longitude. Similarly, while the luminaries axle is
priority, the system will continuously measure the luminous intensity at each C
angle on a conical surface determined by the γ angle, the trace can be looked upon
the woof. See the following figure.
Measurement Principle
3. System Functions
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 3 -
LSG-3000CCD Moving Detector Goniospectroradiometer
The LSG-3000CCD fully meets LM-79 Clause 9.3.1, CIE and GB standards for
Goniophotometric of luminaries, this system is used to measure spatial luminous
intensity distribution of luminaries for floodlight, street lighting and interior lighting,
and other photometric parameters such as spatial iso-intensity curve, intensity
distribution curve of each section (shown in rectangular coordinate system or polar
coordinate system), iso-illuminance distribution curve, luminance limitation curve,
luminaries efficiency, glare grade, effective beam angles, upward luminous flux ratio,
downward luminous flux ratio, total luminous flux, effective luminous flux,
utilization factor and electric parameters (wattage, power factor, voltage and
current) of luminaries etc. The measured data may be saved in formats IES, LDT
(Eulumdat), CIB, TM4, CIE, CEN and CSV for application software of lighting
calculation and reflector design.
LSG-3000CCD Can test all of the above luminaires
4. Specifications
1) The mirror rotates around the tested luminaire with an angle of (γ)±180°
and the tested luminaire rotates around itself with an angle of (C)±180°
2) The accuracy of angle: 0.1°
3) Luminosity Testing Range: Illuminance 0.001lx~99,999lx; Light Intensity
1.0cd~107
cd(detector)
4) Accuracy of photometry: CIE Class A or Class L (option)
5) Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1%
6) Work with high accuracy and quick CCD Spectroradiometer to measure
spatial color parameters.
7) Accuracy of chromaticity coordinate: ±0.0015 or ±0.0005(under standard A
lamp)
8) Spectral Range Wavelength: 380nm ~780nm; Accuracy of wavelength:
±0.5nm
9) English version software can run in Win7, Win8 or Win10
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 4 -
5. Laboratory Requirements
1) Room Requirements according to CIE
A. Dark Room: 3*3*8~30m (W*H*L)
B. Operating Room: 3*3m (W*L)
 The dark room wall, ceiling and floor should be all coated with dull black paint or
be covered by black cloth and black carpet.
 Air-conditioner: be set in the dark room to control the temperature around
lamps to the standard value upon the CIE requirements.
Note: LISUN GROUP engineer dept will submit the Lab Design support documents
according to the customer’s real lab size after the formal purchase order was
confirmed
Model Number LSG-3000ACCD LSG-3000BCCD
Measure Size (mm) Diameter=600 Diameter=1000
Measure Weight (Kg) 20 30
Measure Power(W) 600V/10A, AC/DC 600V/10A, AC/DC
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 5 -
2) Requirements of Eliminating the stray Light
Luminaires must be where the photodetector can only receive the light
reflected by the two moving mirror in the LSG-3000CCD system. The light
given off directly by the luminaries and reflected by the wall and floor is
warded off by the light fence. Internal surface of the dark room and dark
path together with the surface of the light fence should be painted
unpolished black or be covered by black cloth and black carpet.
3) Temperature of the Environment
Temperature around the lamp or luminaries must be 25℃±1℃ during the test.
Exceptions can be given according to relative lamps as following.
a. Tungsten Incandescent Lamp: 25℃±5℃
b. Double-caps Fluorescent Lamp: 25℃±1℃
c. High Pressure Mercury Lamp: 25℃±2℃
d. Metal Halogen Lamp: 25℃±2℃
e. High Pressure Sodium Lamp: 25℃±2℃
f. Low Pressure Sodium Lamp: 25℃±2
4) Airflow
Airflow may be induced by natural aeration, air conditioner or movement of the
luminaries in the goniophotometer, but the speed of the airflow couldn’t
exceed 0.2m/s.
5) Vibration and shock
When the lamp is in lighting, the vibration couldn’t exceed 10m/s2(4 ~
3000Hz), or the moving scope of the lamp couldn’t exceed 30mm (at most
4Hz)
6) Smoke, Dust and Moisture
The test environment must free from smoke, dust or moisture. At the same
time, even not during the measurement, smoke, dust or moisture will also
influence the reflectance of the reflecting mirror and induce more stray light.
So, the test room must be kept clean, no smoke and dry. The humidity should
be less than 60% RH.
6. Service
1) Installation and Training
LISUN GROUP engineers will take responsibility for installation and Training of
the system at the customer’s
2) Period of Guarantee: 24 months
The service is for free except technician’s travel payment if the service
provided by LISUN GROUP implement at the customer’s.
3) Upgrading the applications software for free
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 6 -
7. Design Standard of Device
The construction, technical parameter, test & operate steps as well as data
processing software of LSG-3000CCD Moving Detector Goniospectroradiometer
meet the following requirements:
3.1 CIE Pub. NO.70,”The Measurement of Absolute Luminous Intensity
Distributions”
3.2 CIE DIV.Ⅱ-TC10,”Photometry of Luminaires”
3.3 IES LM-35-1989,”IES Approved Method for Photometric Testing of
Floodlights”
3.4 IES LM-31,”IES Approved Method for Photometric Testing of Roadway
Luminaires”
3.5 IES-LM-79, “Electrical & Photometric Measurements of Solid-State Lighting Products”
3.6 GB/T 7002-1986,“Luminosity Test of Flood Luminaires”
3.7 GB/T 9467-1988, “Luminosity Test of Indoor Luminaires”
3.8 GB/T 9468-1988, “Luminosity Test of Street Luminaires”
3.9 IES 61341 “Method of Measurement of Center Beam Intensity and Beam
Angle(s) of Reflector Lamp”
3.10 CIE Pub.NO.76, “Photometry-the CIE System of Physical Photometry”
8. Typical oversea market customers:
There are many world famous company and lab institute choose Lisun
Goniophtometer, Please get the reference customers’ information from Lisun
Group Oversea Sales Dept.
9. Application Software
This system can export data files as following formats:
This kind of format files can be transferred by other illumination and luminaire
design software such as DiaLux
Application software can also implement essential calculation for lighting design as
iso-illuminance distribution curve on a working plane, luminance limitation curve,
luminaire efficiency, effective beam angle, upward luminous flux ratio, downward
luminous flux ratio, effective luminous flux, utilization factor curve etc.
Lisun Electronics Inc.
http://www.Lisungroup.com
+86(21)51083341
+86(21)51083342
Page 1
Luminaire Property
Luminaire Description: LED Down Light
Luminaire Categorie:
Lamp Categorie:
Lamp Description:
Number of Lamp: 6
Lamp Lumens(lm): 100
Luminous Length(m): 100
Luminous Width(m): 100
Luminous Height(m): 50
Voltage: 220V
Current: 0.029A
Power: 5.8W
Power Factor: 0.907
Test Lab: Lisun Electronics Inc
Photometric Type: Type C
Photometric Results
CIE Class: Direct
Measurement Flux: 412.55 lm
Efficiency: 68.76%
Central Intensity: 184.785cd
Max. Intensity: 184.785cd
Max.Intensity Angle: C:0.0 G:0.0
Beam Angle(50%Imax): L: -47.7 R:45.8
Luminaire Efficacy Rating(LER) : 71.13 lm/W
Upward Ratio: 0.0%
Downward Ratio: 100.0%
Field Angle(10%Imax): Left: -73.7 Right:72.5
C0/C180
90°°
45°
60°
184.8
147.8
110.9
73.9
37.0
-180° 180°0°
cd
37.0
73.9
110.9
147.8
184.8
cd
-180° 180°0°
cd
37.0
73.9
110.9
147.8
184.8
cd
C90/270
90°°
45°
60°
184.8
147.8
110.9
73.9
37.0
-180° 180°0°
cd
37.0
73.9
110.9
147.8
184.8
cd
-180° 180°0°
cd
37.0
73.9
110.9
147.8
184.8
cd
Equipment:LSG-3000 Date:2018-05-31 Operator:zhang
Test Report:
Test Distance:0.941m
Temperature:25 Humidity:65%
Lisun Electronics Inc.
http://www.Lisungroup.com
+86(21)51083341
+86(21)51083342
Page 2
Light intensity data Unit[cd]
CG G0.0 G5.0 G10.0 G15.0 G20.0 G25.0 G30.0 G35.0 G40.0 G45.0
C0.0 184.8 183.4 181.6 176.5 169.7 158.6 145.2 129.7 112.7 95.2
C90.0 184.8 184.3 183.2 180.3 174.2 164.7 152.2 136.6 119.6 101.9
C180.0 184.8 184.3 183.2 180.3 174.2 164.7 152.2 136.6 119.6 101.9
C270.0 184.8 183.4 181.6 176.5 169.7 158.6 145.2 129.7 112.7 95.2
C360.0 184.8 183.4 181.6 176.5 169.7 158.6 145.2 129.7 112.7 95.2
CG G50.0 G55.0 G60.0 G65.0 G70.0 G75.0 G80.0 G85.0 G90.0 G95.0
C0.0 77.8 61.8 47.0 35.0 23.5 13.3 2.2 0.0 0.0 0.0
C90.0 84.1 67.0 51.7 37.9 26.4 15.7 7.7 0.6 0.0 0.0
C180.0 84.1 67.0 51.7 37.9 26.4 15.7 7.7 0.6 0.0 0.0
C270.0 77.8 61.8 47.0 35.0 23.5 13.3 2.2 0.0 0.0 0.0
C360.0 77.8 61.8 47.0 35.0 23.5 13.3 2.2 0.0 0.0 0.0
CG G100.0 G105.0 G110.0 G115.0 G120.0 G125.0 G130.0 G135.0 G140.0 G145.0
C0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
C90.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
C180.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
C270.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
C360.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
CG G150.0 G155.0 G160.0 G165.0 G170.0 G175.0 G180.0
C0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
C90.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
C180.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
C270.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
C360.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Equipment:LSG-3000 Date:2018-05-31 Operator:zhang
Test Report:
Test Distance:0.941m
Temperature:25 Humidity:65%
Lisun Electronics Inc.
http://www.Lisungroup.com
+86(21)51083341
+86(21)51083342
Page 3
Isolx curve
Height: 1 m
3.3
3.3
2.7
2.7
2.0
2.0
1.3
1.3
0.7
0.7
0.0
0.0
0.7
0.7
1.3
1.3
2.0
2.0
2.7
2.7
3.3
3.3
0.0
(10%): 18.5lx (20%): 37.lx (30%): 55.4lx (40%): 73.9lx
(50%): 92.4lx (60%): 110.9lx (70%): 129.4lx (80%): 147.8lx
(90%): 166.3lx (100%): 184.6lx
Equipment:LSG-3000 Date:2018-05-31 Operator:zhang
Test Report:
Test Distance:0.941m
Temperature:25 Humidity:65%
Lisun Electronics Inc.
http://www.Lisungroup.com
+86(21)51083341
+86(21)51083342
Page 4
Space Isolx Curve
(10%): 18.5lx (20%): 37.lx (30%): 55.4lx (40%): 73.9lx
(50%): 92.4lx (60%): 110.9lx (70%): 129.4lx (80%): 147.8lx
(90%): 166.3lx (100%): 184.6lx
Equipment:LSG-3000 Date:2018-05-31 Operator:zhang
Test Report:
Test Distance:0.941m
Temperature:25 Humidity:65%
Lisun Electronics Inc.
http://www.Lisungroup.com
+86(21)51083341
+86(21)51083342
Page 5
Luminance Limitting Curve
Diameter: 0mm
Length: 0mm
Width: 888mm
Height: 0mm
G(°)
85
75
65
55
45
6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4 (cd/m2)
2
3
4
6
8
a / hs
a b c d e f g h
Lum. Limitting Curve (C0/C90)
Glare Quality Service Values Illuminance (lx)
1.15 A 2000 1000 500 ≤300
1.5 B 2000 1000 500 ≤300
1.85 C 2000 1000 500 ≤300
2.2 D 2000 1000 500 ≤300
2.55 E 2000 1000 500 ≤300
(cd/m2)
γ
C0
C90
45° 50° 55° 60° 65° 70° 75° 80° 85°
C0: C90:
3367
3604
3024
3271
2693
2922
2350
2587
2069
2241
1718
1931
1286
1519
322
1112
Equipment:LSG-3000 Date:2018-05-31 Operator:zhang
Test Report:
Test Distance:0.941m
Temperature:25 Humidity:65%
Lisun Electronics Inc.
http://www.Lisungroup.com
+86(21)51083341
+86(21)51083342
Page 6
Cofficiencts of Utilization
RHOCC
RHOW
RCR
0
1
2
3
4
5
6
7
8
9
10
080 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
COEFFCIENTS OF UTILIZATION FOR RHOFC=20
1.19 1.19 1.19 1.16 1.16 1.16 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.00
1.08 1.06 1.05 1.06 1.05 1.03 1.02 1.01 0.99 0.97 0.95 0.94 0.91 0.89 0.87 0.82
0.94 0.92 0.90 0.93 0.90 0.88 0.90 0.87 0.85 0.87 0.83 0.80 0.82 0.78 0.75 0.70
0.82 0.79 0.78 0.82 0.78 0.76 0.80 0.76 0.73 0.77 0.73 0.69 0.74 0.69 0.65 0.61
0.72 0.69 0.68 0.72 0.69 0.66 0.71 0.67 0.63 0.69 0.64 0.60 0.67 0.61 0.57 0.53
0.64 0.61 0.59 0.64 0.61 0.58 0.64 0.59 0.56 0.63 0.57 0.53 0.61 0.55 0.50 0.46
0.57 0.54 0.53 0.57 0.54 0.52 0.57 0.53 0.49 0.57 0.51 0.47 0.56 0.50 0.45 0.41
0.51 0.49 0.47 0.52 0.48 0.46 0.52 0.48 0.44 0.52 0.46 0.42 0.51 0.45 0.40 0.37
0.46 0.44 0.42 0.47 0.44 0.42 0.48 0.43 0.40 0.48 0.42 0.38 0.47 0.41 0.36 0.33
0.42 0.40 0.39 0.43 0.40 0.38 0.44 0.39 0.36 0.44 0.39 0.35 0.44 0.38 0.33 0.30
0.39 0.36 0.35 0.39 0.36 0.34 0.40 0.36 0.33 0.41 0.35 0.32 0.41 0.35 0.30 0.27
Equipment:LSG-3000 Date:2018-05-31 Operator:zhang
Test Report:
Test Distance:0.941m
Temperature:25 Humidity:65%
1 2 3 4 5 6 7 8 9 10 20 40 60 80 100
[m2]
200 400 600 800
1
2
3
4
5
6
7
8
9
10
[N]
10
20
30
40
2m
6m
10m
2m
4m
6m
8m
10m
Budgetary Estimate
Light Flux 412.55lm
M_Factor 0.8/0.8
Aver LX 100lx
Plane H 0
Place C W F
Reflect1 0.7 0.5 0.2
Reflect2 0.5 0.3 0.2
Indoor Budgetary Estimate Chart
Lisun Electronics Inc.
http://www.Lisungroup.com
+86(21)51083341
+86(21)51083342
Page 7
Equipment:LSG-3000 Date:2018-05-31 Operator:zhang
Test Report:
Test Distance:0.941m
Temperature:25 Humidity:65%
Lisun Electronics Inc.
http://www.Lisungroup.com
+86(21)51083341
+86(21)51083342
Page 8
UGR Glare Index
Ceiling 70 70 50 50 30 70 70 50 50 30
Wall 50 30 50 30 30 50 30 50 30 30
Floor 20 20 20 20 20 20 20 20 20 20
Room Size Weft to light axis direction of observation Direction of light axis parallel observation
X Y
2H 2H 14.7 16.0 14.9 15.9 16.5 14.7 15.9 14.8 16.0 16.5
3H 16.3 17.4 16.7 17.9 17.9 16.2 17.4 16.4 17.8 18.0
4H 16.9 18.1 17.4 18.7 18.8 16.9 18.1 17.3 18.5 18.8
6H 17.6 18.5 18.0 18.9 18.9 17.4 18.3 17.8 18.9 19.0
8H 17.8 18.9 18.1 19.0 19.3 17.7 18.7 17.9 19.0 19.3
12H 17.9 18.8 18.1 19.2 19.5 17.7 18.7 18.1 19.2 19.6
4H 2H 15.7 16.6 15.9 16.8 17.0 15.6 16.6 15.8 16.9 17.0
3H 17.5 18.4 17.7 18.4 18.8 17.3 18.2 17.6 18.3 18.7
4H 18.3 18.9 18.5 19.1 19.5 18.0 18.9 18.4 19.1 19.6
6H 18.8 19.5 19.1 19.8 20.2 18.7 19.5 18.9 19.7 20.0
8H 19.0 19.7 19.4 20.0 20.3 19.0 19.5 19.3 20.0 20.3
12H 19.2 19.8 19.7 20.0 20.5 19.1 19.8 19.5 20.1 20.5
8H 4H 18.5 19.2 18.8 19.4 19.8 18.5 19.1 18.7 19.4 19.8
6H 19.3 19.8 19.8 20.2 20.6 19.2 19.7 19.6 20.2 20.5
8H 19.8 20.2 20.2 20.5 20.9 19.6 20.0 20.1 20.4 21.0
12H 20.0 20.4 20.4 20.9 21.1 19.8 20.3 20.3 20.8 21.2
12H 4H 18.6 19.2 19.1 19.6 19.8 18.5 19.0 18.9 19.4 19.8
6H 19.5 20.0 19.9 20.2 20.7 19.4 19.9 19.8 20.2 20.6
8H 19.9 20.3 20.4 20.5 21.1 19.8 20.2 20.3 20.6 21.0
Equipment:LSG-3000 Date:2018-05-31 Operator:zhang
Test Report:
Test Distance:0.941m
Temperature:25 Humidity:65%
GC
0 90
x y Tc Ra x y Tc Ra
0 0.1937 0.3104 6958 73.9 0.1944 0.3109 6856 74.2
10 0.1938 0.3105 6942 73.8 0.1939 0.3104 6940 73.9
20 0.1938 0.3112 6872 73.7 0.1938 0.3108 6912 73.8
30 0.1936 0.3120 6804 73.5 0.1938 0.3112 6872 73.6
40 0.1932 0.3130 6738 73.2 0.1933 0.3119 6836 73.2
50 0.1929 0.3137 6686 72.9 0.1932 0.3126 6772 73.1
60 0.1925 0.3144 6658 72.6 0.1928 0.3133 6740 72.7
70 0.1918 0.3148 6662 72.0 0.1921 0.3138 6734 72.1
80 0.1910 0.3153 6666 71.1 0.1921 0.3149 6634 71.7
90 0.1917 0.3174 6442 66.7 0.1911 0.3159 6614 68.6
100 0.2035 0.3274 5176 40.1 0.2054 0.3264 5134 40.3
110 0.2014 0.3260 5352 44.0 0.2036 0.3248 5304 42.2
120 0.2005 0.3252 5436 47.0 0.2021 0.3258 5326 45.1
130 0.2006 0.3248 5452 47.9 0.1999 0.3244 5510 47.9
140 0.1983 0.3232 5662 49.3 0.1980 0.3237 5650 51.0
150 0.1993 0.3228 5636 49.7 0.1977 0.3227 5728 50.6
160 0.2003 0.3239 5518 45.6 0.1959 0.3230 5804 50.5
170 0.2011 0.3238 5484 43.7 0.1978 0.3251 5576 45.3
180 0.2064 0.3252 5146 35.1 0.2080 0.3260 5026 35.7
The inhomogeneity of Chromaticity:△u=0.0147 △v=0.01423

More Related Content

What's hot

LISUN Goniophotometer with-moving-mirror-lsg-2000
LISUN Goniophotometer with-moving-mirror-lsg-2000LISUN Goniophotometer with-moving-mirror-lsg-2000
LISUN Goniophotometer with-moving-mirror-lsg-2000
世满 江
 
LISUN Near field-type-c-goniophotometer LSG-1900B
LISUN Near field-type-c-goniophotometer LSG-1900BLISUN Near field-type-c-goniophotometer LSG-1900B
LISUN Near field-type-c-goniophotometer LSG-1900B
世满 江
 
Goniophotometer for-automotive-and-signal-lamps
Goniophotometer for-automotive-and-signal-lampsGoniophotometer for-automotive-and-signal-lamps
Goniophotometer for-automotive-and-signal-lamps
世满 江
 
High Precision Goniophotometer for Automotive and Traffic Signal Lamps
High Precision Goniophotometer for Automotive and Traffic Signal LampsHigh Precision Goniophotometer for Automotive and Traffic Signal Lamps
High Precision Goniophotometer for Automotive and Traffic Signal Lamps
Lisun Group
 
Influence of artificial soiling on the power losses of different PV technologies
Influence of artificial soiling on the power losses of different PV technologiesInfluence of artificial soiling on the power losses of different PV technologies
Influence of artificial soiling on the power losses of different PV technologies
Sandia National Laboratories: Energy & Climate: Renewables
 
Samsung Techwin SCB-9050 Data Sheet
Samsung Techwin SCB-9050 Data SheetSamsung Techwin SCB-9050 Data Sheet
Samsung Techwin SCB-9050 Data Sheet
JMAC Supply
 
Goniophotometers lsg-1600b
Goniophotometers lsg-1600bGoniophotometers lsg-1600b
Goniophotometers lsg-1600b
世满 江
 
FLIR i50 Thermal Imaging Infrared Camera - Datasheet Manual
FLIR i50 Thermal Imaging Infrared Camera - Datasheet ManualFLIR i50 Thermal Imaging Infrared Camera - Datasheet Manual
FLIR i50 Thermal Imaging Infrared Camera - Datasheet ManualAngus Sankaran
 
Spotlight 150i and 200i
Spotlight 150i and 200iSpotlight 150i and 200i
Spotlight 150i and 200i
PerkinElmer, Inc.
 
FT-IR, NIR Microscopy and Imaging
FT-IR, NIR Microscopy and ImagingFT-IR, NIR Microscopy and Imaging
FT-IR, NIR Microscopy and Imaging
PerkinElmer, Inc.
 
Infrared Technology - Seeing the Invisible (Part Two: Camera Technology)
Infrared Technology - Seeing the Invisible (Part Two: Camera Technology)Infrared Technology - Seeing the Invisible (Part Two: Camera Technology)
Infrared Technology - Seeing the Invisible (Part Two: Camera Technology)
Allied Vision
 
Forest fire detection & alarm thermal imaging camera
Forest fire detection & alarm thermal imaging camera  Forest fire detection & alarm thermal imaging camera
Forest fire detection & alarm thermal imaging camera
Elsa Wang
 
Imaging beyond the visible - An Overview of Short-Wave Infrared (SWIR) Techno...
Imaging beyond the visible - An Overview of Short-Wave Infrared (SWIR) Techno...Imaging beyond the visible - An Overview of Short-Wave Infrared (SWIR) Techno...
Imaging beyond the visible - An Overview of Short-Wave Infrared (SWIR) Techno...
Allied Vision
 
Night vision infrared thermal imaging and ir laser technology
Night vision infrared thermal imaging and ir laser technologyNight vision infrared thermal imaging and ir laser technology
Night vision infrared thermal imaging and ir laser technology
Elsa Wang
 

What's hot (15)

LISUN Goniophotometer with-moving-mirror-lsg-2000
LISUN Goniophotometer with-moving-mirror-lsg-2000LISUN Goniophotometer with-moving-mirror-lsg-2000
LISUN Goniophotometer with-moving-mirror-lsg-2000
 
LISUN Near field-type-c-goniophotometer LSG-1900B
LISUN Near field-type-c-goniophotometer LSG-1900BLISUN Near field-type-c-goniophotometer LSG-1900B
LISUN Near field-type-c-goniophotometer LSG-1900B
 
Goniophotometer for-automotive-and-signal-lamps
Goniophotometer for-automotive-and-signal-lampsGoniophotometer for-automotive-and-signal-lamps
Goniophotometer for-automotive-and-signal-lamps
 
High Precision Goniophotometer for Automotive and Traffic Signal Lamps
High Precision Goniophotometer for Automotive and Traffic Signal LampsHigh Precision Goniophotometer for Automotive and Traffic Signal Lamps
High Precision Goniophotometer for Automotive and Traffic Signal Lamps
 
Influence of artificial soiling on the power losses of different PV technologies
Influence of artificial soiling on the power losses of different PV technologiesInfluence of artificial soiling on the power losses of different PV technologies
Influence of artificial soiling on the power losses of different PV technologies
 
Samsung Techwin SCB-9050 Data Sheet
Samsung Techwin SCB-9050 Data SheetSamsung Techwin SCB-9050 Data Sheet
Samsung Techwin SCB-9050 Data Sheet
 
Goniophotometers lsg-1600b
Goniophotometers lsg-1600bGoniophotometers lsg-1600b
Goniophotometers lsg-1600b
 
FLIR i50 Thermal Imaging Infrared Camera - Datasheet Manual
FLIR i50 Thermal Imaging Infrared Camera - Datasheet ManualFLIR i50 Thermal Imaging Infrared Camera - Datasheet Manual
FLIR i50 Thermal Imaging Infrared Camera - Datasheet Manual
 
Spotlight 150i and 200i
Spotlight 150i and 200iSpotlight 150i and 200i
Spotlight 150i and 200i
 
FT-IR, NIR Microscopy and Imaging
FT-IR, NIR Microscopy and ImagingFT-IR, NIR Microscopy and Imaging
FT-IR, NIR Microscopy and Imaging
 
Infrared Technology - Seeing the Invisible (Part Two: Camera Technology)
Infrared Technology - Seeing the Invisible (Part Two: Camera Technology)Infrared Technology - Seeing the Invisible (Part Two: Camera Technology)
Infrared Technology - Seeing the Invisible (Part Two: Camera Technology)
 
GfG_G888_
GfG_G888_GfG_G888_
GfG_G888_
 
Forest fire detection & alarm thermal imaging camera
Forest fire detection & alarm thermal imaging camera  Forest fire detection & alarm thermal imaging camera
Forest fire detection & alarm thermal imaging camera
 
Imaging beyond the visible - An Overview of Short-Wave Infrared (SWIR) Techno...
Imaging beyond the visible - An Overview of Short-Wave Infrared (SWIR) Techno...Imaging beyond the visible - An Overview of Short-Wave Infrared (SWIR) Techno...
Imaging beyond the visible - An Overview of Short-Wave Infrared (SWIR) Techno...
 
Night vision infrared thermal imaging and ir laser technology
Night vision infrared thermal imaging and ir laser technologyNight vision infrared thermal imaging and ir laser technology
Night vision infrared thermal imaging and ir laser technology
 

Similar to Moving Detector Goniophotometer

Moving detector-goniophotometer-lsg-3000
Moving detector-goniophotometer-lsg-3000Moving detector-goniophotometer-lsg-3000
Moving detector-goniophotometer-lsg-3000
世满 江
 
Moving detector-goniospectroradiometer-lsg-3000ccd
Moving detector-goniospectroradiometer-lsg-3000ccdMoving detector-goniospectroradiometer-lsg-3000ccd
Moving detector-goniospectroradiometer-lsg-3000ccd
世满 江
 
Moving detector-goniophotometer
Moving detector-goniophotometerMoving detector-goniophotometer
Moving detector-goniophotometer
世满 江
 
Moving Detector Goniophotometer5000
Moving Detector Goniophotometer5000Moving Detector Goniophotometer5000
Moving Detector Goniophotometer5000
Lisun Group
 
Goniophotometer with Rotating Mirror
Goniophotometer with Rotating MirrorGoniophotometer with Rotating Mirror
Goniophotometer with Rotating Mirror
Lisun Group
 
Near field-type-c-goniophotometer
Near field-type-c-goniophotometerNear field-type-c-goniophotometer
Near field-type-c-goniophotometer
世满 江
 
Moving detector-goniospectroradiometer
Moving detector-goniospectroradiometerMoving detector-goniospectroradiometer
Moving detector-goniospectroradiometer
世满 江
 
Moving detector-goniospectroradiometer
Moving detector-goniospectroradiometerMoving detector-goniospectroradiometer
Moving detector-goniospectroradiometer
世满 江
 
Goniophotometer for-automotive-and-signal-lamps
Goniophotometer for-automotive-and-signal-lampsGoniophotometer for-automotive-and-signal-lamps
Goniophotometer for-automotive-and-signal-lamps
世满 江
 
High precision-rotation-luminaire-goniospectroradiometer
High precision-rotation-luminaire-goniospectroradiometerHigh precision-rotation-luminaire-goniospectroradiometer
High precision-rotation-luminaire-goniospectroradiometer
世满 江
 
High precision-rotation-luminaire-goniospectroradiometer
High precision-rotation-luminaire-goniospectroradiometerHigh precision-rotation-luminaire-goniospectroradiometer
High precision-rotation-luminaire-goniospectroradiometer
世满 江
 
Rotation Luminaire Goniophotometer (Big Size)
Rotation Luminaire Goniophotometer (Big Size)Rotation Luminaire Goniophotometer (Big Size)
Rotation Luminaire Goniophotometer (Big Size)
Lisun Group
 
Goniospectroradiometer with-moving-mirror
Goniospectroradiometer with-moving-mirrorGoniospectroradiometer with-moving-mirror
Goniospectroradiometer with-moving-mirror
世满 江
 
Goniospectroradiometer with-moving-mirror
Goniospectroradiometer with-moving-mirrorGoniospectroradiometer with-moving-mirror
Goniospectroradiometer with-moving-mirror
世满 江
 
Goniospectroradiometer with-moving-mirror
Goniospectroradiometer with-moving-mirrorGoniospectroradiometer with-moving-mirror
Goniospectroradiometer with-moving-mirror
世满 江
 
LISUN Goniospectroradiometers LSG-1800CCD
LISUN Goniospectroradiometers LSG-1800CCDLISUN Goniospectroradiometers LSG-1800CCD
LISUN Goniospectroradiometers LSG-1800CCD
世满 江
 
LISUN Moving detector-goniospectroradiometer LSG-5000CCD
LISUN Moving detector-goniospectroradiometer LSG-5000CCDLISUN Moving detector-goniospectroradiometer LSG-5000CCD
LISUN Moving detector-goniospectroradiometer LSG-5000CCD
世满 江
 
Goniospectroradiometer with-moving-mirror-lsg-2000ccd
Goniospectroradiometer with-moving-mirror-lsg-2000ccdGoniospectroradiometer with-moving-mirror-lsg-2000ccd
Goniospectroradiometer with-moving-mirror-lsg-2000ccd
世满 江
 
LISUN Goniophotometer for Automotive and Signal Lamps Lsg-1950
LISUN Goniophotometer for Automotive and Signal Lamps Lsg-1950LISUN Goniophotometer for Automotive and Signal Lamps Lsg-1950
LISUN Goniophotometer for Automotive and Signal Lamps Lsg-1950
世满 江
 
Goniospectroradiometers
GoniospectroradiometersGoniospectroradiometers
Goniospectroradiometers
世满 江
 

Similar to Moving Detector Goniophotometer (20)

Moving detector-goniophotometer-lsg-3000
Moving detector-goniophotometer-lsg-3000Moving detector-goniophotometer-lsg-3000
Moving detector-goniophotometer-lsg-3000
 
Moving detector-goniospectroradiometer-lsg-3000ccd
Moving detector-goniospectroradiometer-lsg-3000ccdMoving detector-goniospectroradiometer-lsg-3000ccd
Moving detector-goniospectroradiometer-lsg-3000ccd
 
Moving detector-goniophotometer
Moving detector-goniophotometerMoving detector-goniophotometer
Moving detector-goniophotometer
 
Moving Detector Goniophotometer5000
Moving Detector Goniophotometer5000Moving Detector Goniophotometer5000
Moving Detector Goniophotometer5000
 
Goniophotometer with Rotating Mirror
Goniophotometer with Rotating MirrorGoniophotometer with Rotating Mirror
Goniophotometer with Rotating Mirror
 
Near field-type-c-goniophotometer
Near field-type-c-goniophotometerNear field-type-c-goniophotometer
Near field-type-c-goniophotometer
 
Moving detector-goniospectroradiometer
Moving detector-goniospectroradiometerMoving detector-goniospectroradiometer
Moving detector-goniospectroradiometer
 
Moving detector-goniospectroradiometer
Moving detector-goniospectroradiometerMoving detector-goniospectroradiometer
Moving detector-goniospectroradiometer
 
Goniophotometer for-automotive-and-signal-lamps
Goniophotometer for-automotive-and-signal-lampsGoniophotometer for-automotive-and-signal-lamps
Goniophotometer for-automotive-and-signal-lamps
 
High precision-rotation-luminaire-goniospectroradiometer
High precision-rotation-luminaire-goniospectroradiometerHigh precision-rotation-luminaire-goniospectroradiometer
High precision-rotation-luminaire-goniospectroradiometer
 
High precision-rotation-luminaire-goniospectroradiometer
High precision-rotation-luminaire-goniospectroradiometerHigh precision-rotation-luminaire-goniospectroradiometer
High precision-rotation-luminaire-goniospectroradiometer
 
Rotation Luminaire Goniophotometer (Big Size)
Rotation Luminaire Goniophotometer (Big Size)Rotation Luminaire Goniophotometer (Big Size)
Rotation Luminaire Goniophotometer (Big Size)
 
Goniospectroradiometer with-moving-mirror
Goniospectroradiometer with-moving-mirrorGoniospectroradiometer with-moving-mirror
Goniospectroradiometer with-moving-mirror
 
Goniospectroradiometer with-moving-mirror
Goniospectroradiometer with-moving-mirrorGoniospectroradiometer with-moving-mirror
Goniospectroradiometer with-moving-mirror
 
Goniospectroradiometer with-moving-mirror
Goniospectroradiometer with-moving-mirrorGoniospectroradiometer with-moving-mirror
Goniospectroradiometer with-moving-mirror
 
LISUN Goniospectroradiometers LSG-1800CCD
LISUN Goniospectroradiometers LSG-1800CCDLISUN Goniospectroradiometers LSG-1800CCD
LISUN Goniospectroradiometers LSG-1800CCD
 
LISUN Moving detector-goniospectroradiometer LSG-5000CCD
LISUN Moving detector-goniospectroradiometer LSG-5000CCDLISUN Moving detector-goniospectroradiometer LSG-5000CCD
LISUN Moving detector-goniospectroradiometer LSG-5000CCD
 
Goniospectroradiometer with-moving-mirror-lsg-2000ccd
Goniospectroradiometer with-moving-mirror-lsg-2000ccdGoniospectroradiometer with-moving-mirror-lsg-2000ccd
Goniospectroradiometer with-moving-mirror-lsg-2000ccd
 
LISUN Goniophotometer for Automotive and Signal Lamps Lsg-1950
LISUN Goniophotometer for Automotive and Signal Lamps Lsg-1950LISUN Goniophotometer for Automotive and Signal Lamps Lsg-1950
LISUN Goniophotometer for Automotive and Signal Lamps Lsg-1950
 
Goniospectroradiometers
GoniospectroradiometersGoniospectroradiometers
Goniospectroradiometers
 

More from Lisun Group

Electronic Ballast Tester
Electronic Ballast TesterElectronic Ballast Tester
Electronic Ballast Tester
Lisun Group
 
LED Power Driver Tester
LED Power Driver TesterLED Power Driver Tester
LED Power Driver Tester
Lisun Group
 
UV aging test Chamber
UV aging test ChamberUV aging test Chamber
UV aging test Chamber
Lisun Group
 
Spectral Colorimeter
Spectral ColorimeterSpectral Colorimeter
Spectral Colorimeter
Lisun Group
 
Near Field Moving Detector Goniophotometer
Near Field Moving Detector GoniophotometerNear Field Moving Detector Goniophotometer
Near Field Moving Detector Goniophotometer
Lisun Group
 
Rotation Luminaire Goniophotometer (Big Size)1600B
Rotation Luminaire Goniophotometer (Big Size)1600BRotation Luminaire Goniophotometer (Big Size)1600B
Rotation Luminaire Goniophotometer (Big Size)1600B
Lisun Group
 
Compact Goniophotometer
Compact GoniophotometerCompact Goniophotometer
Compact Goniophotometer
Lisun Group
 
Rotation Luminaire Goniospectroradiometer
Rotation Luminaire GoniospectroradiometerRotation Luminaire Goniospectroradiometer
Rotation Luminaire Goniospectroradiometer
Lisun Group
 
Photo and Electric Tester
Photo and Electric TesterPhoto and Electric Tester
Photo and Electric Tester
Lisun Group
 
Compact CCD Spectroradiometer
Compact CCD SpectroradiometerCompact CCD Spectroradiometer
Compact CCD Spectroradiometer
Lisun Group
 
Portable CCD Spectroradiometer
Portable CCD SpectroradiometerPortable CCD Spectroradiometer
Portable CCD Spectroradiometer
Lisun Group
 
LED Driver online Tester
LED Driver online TesterLED Driver online Tester
LED Driver online Tester
Lisun Group
 
LED Optical Aging Test Instrument
LED Optical Aging Test InstrumentLED Optical Aging Test Instrument
LED Optical Aging Test Instrument
Lisun Group
 
Portable Spectrophotometer
Portable SpectrophotometerPortable Spectrophotometer
Portable Spectrophotometer
Lisun Group
 
Optical Radiation Safety Test System
Optical Radiation Safety Test SystemOptical Radiation Safety Test System
Optical Radiation Safety Test System
Lisun Group
 
Combined EMC Test System
Combined EMC Test SystemCombined EMC Test System
Combined EMC Test System
Lisun Group
 
EMI Receiver
EMI ReceiverEMI Receiver
EMI Receiver
Lisun Group
 
Desktop Spectrophotometer
Desktop SpectrophotometerDesktop Spectrophotometer
Desktop Spectrophotometer
Lisun Group
 
Colorimeter
ColorimeterColorimeter
Colorimeter
Lisun Group
 
Single angles gloss meter
Single angles gloss meterSingle angles gloss meter
Single angles gloss meter
Lisun Group
 

More from Lisun Group (20)

Electronic Ballast Tester
Electronic Ballast TesterElectronic Ballast Tester
Electronic Ballast Tester
 
LED Power Driver Tester
LED Power Driver TesterLED Power Driver Tester
LED Power Driver Tester
 
UV aging test Chamber
UV aging test ChamberUV aging test Chamber
UV aging test Chamber
 
Spectral Colorimeter
Spectral ColorimeterSpectral Colorimeter
Spectral Colorimeter
 
Near Field Moving Detector Goniophotometer
Near Field Moving Detector GoniophotometerNear Field Moving Detector Goniophotometer
Near Field Moving Detector Goniophotometer
 
Rotation Luminaire Goniophotometer (Big Size)1600B
Rotation Luminaire Goniophotometer (Big Size)1600BRotation Luminaire Goniophotometer (Big Size)1600B
Rotation Luminaire Goniophotometer (Big Size)1600B
 
Compact Goniophotometer
Compact GoniophotometerCompact Goniophotometer
Compact Goniophotometer
 
Rotation Luminaire Goniospectroradiometer
Rotation Luminaire GoniospectroradiometerRotation Luminaire Goniospectroradiometer
Rotation Luminaire Goniospectroradiometer
 
Photo and Electric Tester
Photo and Electric TesterPhoto and Electric Tester
Photo and Electric Tester
 
Compact CCD Spectroradiometer
Compact CCD SpectroradiometerCompact CCD Spectroradiometer
Compact CCD Spectroradiometer
 
Portable CCD Spectroradiometer
Portable CCD SpectroradiometerPortable CCD Spectroradiometer
Portable CCD Spectroradiometer
 
LED Driver online Tester
LED Driver online TesterLED Driver online Tester
LED Driver online Tester
 
LED Optical Aging Test Instrument
LED Optical Aging Test InstrumentLED Optical Aging Test Instrument
LED Optical Aging Test Instrument
 
Portable Spectrophotometer
Portable SpectrophotometerPortable Spectrophotometer
Portable Spectrophotometer
 
Optical Radiation Safety Test System
Optical Radiation Safety Test SystemOptical Radiation Safety Test System
Optical Radiation Safety Test System
 
Combined EMC Test System
Combined EMC Test SystemCombined EMC Test System
Combined EMC Test System
 
EMI Receiver
EMI ReceiverEMI Receiver
EMI Receiver
 
Desktop Spectrophotometer
Desktop SpectrophotometerDesktop Spectrophotometer
Desktop Spectrophotometer
 
Colorimeter
ColorimeterColorimeter
Colorimeter
 
Single angles gloss meter
Single angles gloss meterSingle angles gloss meter
Single angles gloss meter
 

Recently uploaded

Student information management system project report ii.pdf
Student information management system project report ii.pdfStudent information management system project report ii.pdf
Student information management system project report ii.pdf
Kamal Acharya
 
Forklift Classes Overview by Intella Parts
Forklift Classes Overview by Intella PartsForklift Classes Overview by Intella Parts
Forklift Classes Overview by Intella Parts
Intella Parts
 
Recycled Concrete Aggregate in Construction Part III
Recycled Concrete Aggregate in Construction Part IIIRecycled Concrete Aggregate in Construction Part III
Recycled Concrete Aggregate in Construction Part III
Aditya Rajan Patra
 
Water Industry Process Automation and Control Monthly - May 2024.pdf
Water Industry Process Automation and Control Monthly - May 2024.pdfWater Industry Process Automation and Control Monthly - May 2024.pdf
Water Industry Process Automation and Control Monthly - May 2024.pdf
Water Industry Process Automation & Control
 
Railway Signalling Principles Edition 3.pdf
Railway Signalling Principles Edition 3.pdfRailway Signalling Principles Edition 3.pdf
Railway Signalling Principles Edition 3.pdf
TeeVichai
 
NUMERICAL SIMULATIONS OF HEAT AND MASS TRANSFER IN CONDENSING HEAT EXCHANGERS...
NUMERICAL SIMULATIONS OF HEAT AND MASS TRANSFER IN CONDENSING HEAT EXCHANGERS...NUMERICAL SIMULATIONS OF HEAT AND MASS TRANSFER IN CONDENSING HEAT EXCHANGERS...
NUMERICAL SIMULATIONS OF HEAT AND MASS TRANSFER IN CONDENSING HEAT EXCHANGERS...
ssuser7dcef0
 
CME397 Surface Engineering- Professional Elective
CME397 Surface Engineering- Professional ElectiveCME397 Surface Engineering- Professional Elective
CME397 Surface Engineering- Professional Elective
karthi keyan
 
Final project report on grocery store management system..pdf
Final project report on grocery store management system..pdfFinal project report on grocery store management system..pdf
Final project report on grocery store management system..pdf
Kamal Acharya
 
MCQ Soil mechanics questions (Soil shear strength).pdf
MCQ Soil mechanics questions (Soil shear strength).pdfMCQ Soil mechanics questions (Soil shear strength).pdf
MCQ Soil mechanics questions (Soil shear strength).pdf
Osamah Alsalih
 
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
MdTanvirMahtab2
 
AP LAB PPT.pdf ap lab ppt no title specific
AP LAB PPT.pdf ap lab ppt no title specificAP LAB PPT.pdf ap lab ppt no title specific
AP LAB PPT.pdf ap lab ppt no title specific
BrazilAccount1
 
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
Amil Baba Dawood bangali
 
ML for identifying fraud using open blockchain data.pptx
ML for identifying fraud using open blockchain data.pptxML for identifying fraud using open blockchain data.pptx
ML for identifying fraud using open blockchain data.pptx
Vijay Dialani, PhD
 
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdfHybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
fxintegritypublishin
 
block diagram and signal flow graph representation
block diagram and signal flow graph representationblock diagram and signal flow graph representation
block diagram and signal flow graph representation
Divya Somashekar
 
Heap Sort (SS).ppt FOR ENGINEERING GRADUATES, BCA, MCA, MTECH, BSC STUDENTS
Heap Sort (SS).ppt FOR ENGINEERING GRADUATES, BCA, MCA, MTECH, BSC STUDENTSHeap Sort (SS).ppt FOR ENGINEERING GRADUATES, BCA, MCA, MTECH, BSC STUDENTS
Heap Sort (SS).ppt FOR ENGINEERING GRADUATES, BCA, MCA, MTECH, BSC STUDENTS
Soumen Santra
 
AKS UNIVERSITY Satna Final Year Project By OM Hardaha.pdf
AKS UNIVERSITY Satna Final Year Project By OM Hardaha.pdfAKS UNIVERSITY Satna Final Year Project By OM Hardaha.pdf
AKS UNIVERSITY Satna Final Year Project By OM Hardaha.pdf
SamSarthak3
 
space technology lecture notes on satellite
space technology lecture notes on satellitespace technology lecture notes on satellite
space technology lecture notes on satellite
ongomchris
 
Unbalanced Three Phase Systems and circuits.pptx
Unbalanced Three Phase Systems and circuits.pptxUnbalanced Three Phase Systems and circuits.pptx
Unbalanced Three Phase Systems and circuits.pptx
ChristineTorrepenida1
 
Immunizing Image Classifiers Against Localized Adversary Attacks
Immunizing Image Classifiers Against Localized Adversary AttacksImmunizing Image Classifiers Against Localized Adversary Attacks
Immunizing Image Classifiers Against Localized Adversary Attacks
gerogepatton
 

Recently uploaded (20)

Student information management system project report ii.pdf
Student information management system project report ii.pdfStudent information management system project report ii.pdf
Student information management system project report ii.pdf
 
Forklift Classes Overview by Intella Parts
Forklift Classes Overview by Intella PartsForklift Classes Overview by Intella Parts
Forklift Classes Overview by Intella Parts
 
Recycled Concrete Aggregate in Construction Part III
Recycled Concrete Aggregate in Construction Part IIIRecycled Concrete Aggregate in Construction Part III
Recycled Concrete Aggregate in Construction Part III
 
Water Industry Process Automation and Control Monthly - May 2024.pdf
Water Industry Process Automation and Control Monthly - May 2024.pdfWater Industry Process Automation and Control Monthly - May 2024.pdf
Water Industry Process Automation and Control Monthly - May 2024.pdf
 
Railway Signalling Principles Edition 3.pdf
Railway Signalling Principles Edition 3.pdfRailway Signalling Principles Edition 3.pdf
Railway Signalling Principles Edition 3.pdf
 
NUMERICAL SIMULATIONS OF HEAT AND MASS TRANSFER IN CONDENSING HEAT EXCHANGERS...
NUMERICAL SIMULATIONS OF HEAT AND MASS TRANSFER IN CONDENSING HEAT EXCHANGERS...NUMERICAL SIMULATIONS OF HEAT AND MASS TRANSFER IN CONDENSING HEAT EXCHANGERS...
NUMERICAL SIMULATIONS OF HEAT AND MASS TRANSFER IN CONDENSING HEAT EXCHANGERS...
 
CME397 Surface Engineering- Professional Elective
CME397 Surface Engineering- Professional ElectiveCME397 Surface Engineering- Professional Elective
CME397 Surface Engineering- Professional Elective
 
Final project report on grocery store management system..pdf
Final project report on grocery store management system..pdfFinal project report on grocery store management system..pdf
Final project report on grocery store management system..pdf
 
MCQ Soil mechanics questions (Soil shear strength).pdf
MCQ Soil mechanics questions (Soil shear strength).pdfMCQ Soil mechanics questions (Soil shear strength).pdf
MCQ Soil mechanics questions (Soil shear strength).pdf
 
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
 
AP LAB PPT.pdf ap lab ppt no title specific
AP LAB PPT.pdf ap lab ppt no title specificAP LAB PPT.pdf ap lab ppt no title specific
AP LAB PPT.pdf ap lab ppt no title specific
 
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
 
ML for identifying fraud using open blockchain data.pptx
ML for identifying fraud using open blockchain data.pptxML for identifying fraud using open blockchain data.pptx
ML for identifying fraud using open blockchain data.pptx
 
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdfHybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
 
block diagram and signal flow graph representation
block diagram and signal flow graph representationblock diagram and signal flow graph representation
block diagram and signal flow graph representation
 
Heap Sort (SS).ppt FOR ENGINEERING GRADUATES, BCA, MCA, MTECH, BSC STUDENTS
Heap Sort (SS).ppt FOR ENGINEERING GRADUATES, BCA, MCA, MTECH, BSC STUDENTSHeap Sort (SS).ppt FOR ENGINEERING GRADUATES, BCA, MCA, MTECH, BSC STUDENTS
Heap Sort (SS).ppt FOR ENGINEERING GRADUATES, BCA, MCA, MTECH, BSC STUDENTS
 
AKS UNIVERSITY Satna Final Year Project By OM Hardaha.pdf
AKS UNIVERSITY Satna Final Year Project By OM Hardaha.pdfAKS UNIVERSITY Satna Final Year Project By OM Hardaha.pdf
AKS UNIVERSITY Satna Final Year Project By OM Hardaha.pdf
 
space technology lecture notes on satellite
space technology lecture notes on satellitespace technology lecture notes on satellite
space technology lecture notes on satellite
 
Unbalanced Three Phase Systems and circuits.pptx
Unbalanced Three Phase Systems and circuits.pptxUnbalanced Three Phase Systems and circuits.pptx
Unbalanced Three Phase Systems and circuits.pptx
 
Immunizing Image Classifiers Against Localized Adversary Attacks
Immunizing Image Classifiers Against Localized Adversary AttacksImmunizing Image Classifiers Against Localized Adversary Attacks
Immunizing Image Classifiers Against Localized Adversary Attacks
 

Moving Detector Goniophotometer

  • 1. Moving Detector Goniophotometer (LSG-3000) Brochure Global Office of Lisun Electronics Inc. http://www.Lisungroup.com Lisun Group (Hong Kong) Limited Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon, Hong Kong Tel: 00852-68852050 Fax: 00852-30785638 Email: SalesHK@Lisungroup.com Lisun Electronics (Shanghai) Co., Ltd Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading District, Shanghai, 201802, China Tel: +86(21)5108 3341 Fax: +86(21)5108 3342 Email: SalesSH@Lisungroup.com Lisun Sales Rep Office (USA) Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A. Email: Sales@Lisungroup.com Lisun China Factory Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China Tel: +86-189-1799-6096 Email: Engineering@Lisungroup.com Lead in CFL & LED Test Instruments
  • 2. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 1 - 1. System Configuration A. LSG-3000 Goniophotometric System:  Goniometric Rotating Console: Famous brand Motor and Angle encoder System to keep the test accuracy. Both Far Field and Near Field Test.  High Reflective Moving Mirror: Special design and produced to keep high reflective value.  Class A Constant Temperature Photo Detector  Cross-beam Laser System for Calibrating  English Measuring Software  Two sets of luminaries Clamps: multi-functions  Oversea Delivery and Packing: all of the instruments and accessories will be packed with Fumigation free three plywood, include the delivery cost to Shanghai sea port B. SLS-100W DC Standard Light Intensity Lamp C. LS2012 Digital Power Meter: High Accuracy to measure AC and DC voltage, current, power and power factor, also measure harmonic D. DC3005 CC & CV DC Power Source: DC3005output is 30V/5A. Option can be DC6010 (output is 60V/10A) and DC12005 (output is 120V/5A) E. LSP-500VAS AC Power Source: 500VA AC Power Source F. CASE-19IN 19inch Standard Instruments Cabinet. Full View for LSG-3000 Moving Detector Goniophotometer Note: PC and Printer prepared by the customer (request at least three USB ports)
  • 3. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 2 - 2. Measurement Principle LSG-3000 Moving Detector Goniophotometer is full meet LM-79 Clause 9.3.1 request. The tested lamp will keep burning position and be fixed, near field detector move together with the big mirror in a line, and the far field detector will move with the big mirror synchronously. The detector will always sense the light directly from the luminaries. The rotation priority is determined by the software. If mirror axle is took precedence of rotation, the goniophotometer will continuously measure the luminous intensity at each γ angle on a vertical plane determined by the C angle, the measuring trace is equivalent to the longitude. Similarly, while the luminaries axle is priority, the system will continuously measure the luminous intensity at each C angle on a conical surface determined by the γ angle, the trace can be looked upon the woof. See the following figure. Measurement Principle 3. System Functions
  • 4. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 3 - LSG-3000 Moving Detector Goniophotometer The LSG-3000 full meet LM-79 Clause 9.3.1, CIE and GB standards for Goniophotometric of luminaries, this system is used to measure spatial luminous intensity distribution of luminaries for floodlight, street lighting and interior lighting, and other photometric parameters such as spatial iso-intensity curve, intensity distribution curve of each section (shown in rectangular coordinate system or polar coordinate system), iso-illuminance distribution curve, luminance limitation curve, luminaries efficiency, glare grade, effective beam angles, upward luminous flux ratio, downward luminous flux ratio, total luminous flux, effective luminous flux, utilization factor and electric parameters (wattage, power factor, voltage and current) of luminaries etc. The measured data may be saved in formats IES, LDT (Eulumdat), CIB, TM4, CIE, CEN and CSV for application software of lighting calculation and reflector design. LSG-3000 Can test all of the above luminaires 4. Specifications 1) The mirror rotates around the tested luminaire with an angle of (γ)±180° and the tested luminaire rotates around itself with an angle of (C)±180° 2) The accuracy of angle: 0.1° Resolution of angle: 0.01° 3) Luminosity Testing Range: Illuminance 0.001lx~99,999lx; Light Intensity 1.0cd~107 cd(detector) 4) Accuracy of photometry: CIE Class A or Class L (option) 5) Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1% 6) English version software can run in Win7, Win8 or Win10 Model Number LSG-3000A LSG-3000B Measure Size (mm) Diameter=600 Diameter=1000 Measure Weight (Kg) 20 30 Measure Power(W) 600V/10A, AC/DC 600V/10A, AC/DC
  • 5. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 4 - 5. Laboratory Requirements 1) Room Requirements according to CIE A. Dark Room: 3*3*8~30m (W*H*L) B. Operating Room: 3*3m (W*L)  The dark room wall, ceiling and floor should be all coated with dull black paint or be covered by black cloth and black carpet.  Air-conditioner: be set in the dark room to control the temperature around lamps to the standard value upon the CIE requirements. Note: LISUN GROUP engineer dept will submit the Lab Design support documents according to the customer’s real lab size after the formal purchase order was confirmed 2) Requirements of Eliminating the stray Light Luminaires must be where the photodetector can only receive the light reflected by the two moving mirror in the LSG-3000 system. The light given off directly by the luminaries and reflected by the wall and floor is warded off by the light fence. Internal surface of the dark room and dark path together with the surface of the light fence should be painted unpolished black or be covered by black cloth and black carpet.
  • 6. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 5 - 3) Temperature of the Environment Temperature around the lamp or luminaries must be 25℃±1℃ during the test. Exceptions can be given according to relative lamps as following. a. Tungsten Incandescent Lamp: 25℃±5℃ b. Double-caps Fluorescent Lamp: 25℃±1℃ c. High Pressure Mercury Lamp: 25℃±2℃ d. Metal Halogen Lamp: 25℃±2℃ e. High Pressure Sodium Lamp: 25℃±2℃ f. Low Pressure Sodium Lamp: 25℃±2 4) Airflow Airflow may be induced by natural aeration, air conditioner or movement of the luminaries in the goniophotometer, but the speed of the airflow couldn’t exceed 0.2m/s. 5) Vibration and shock When the lamp is in lighting, the vibration couldn’t exceed 10m/s2(4 ~ 3000Hz), or the moving scope of the lamp couldn’t exceed 30mm (at most 4Hz) 6) Smoke, Dust and Moisture The test environment must free from smoke, dust or moisture. At the same time, even not during the measurement, smoke, dust or moisture will also influence the reflectance of the reflecting mirror and induce more stray light. So, the test room must be kept clean, no smoke and dry. The humidity should be less than 60% RH. 6. Service 1) Installation and Training LISUN GROUP engineers will take responsibility for installation and Training of the system at the customer’s 2) Period of Guarantee: 24 months The service is for free except technician’s travel payment if the service provided by LISUN GROUP implement at the customer’s. 3) Upgrading the applications software for free 7. Design Standard of Device The construction, technical parameter, test & operate steps as well as data processing software of LSG-3000 Moving Detector Goniophotometer meet the following requirements: 3.1 CIE Pub. NO.70,”The Measurement of Absolute Luminous Intensity
  • 7. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 6 - Distributions” 3.2 CIE DIV.Ⅱ-TC10,”Photometry of Luminaires” 3.3 IES LM-35-1989,”IES Approved Method for Photometric Testing of Floodlights” 3.4 IES LM-31,”IES Approved Method for Photometric Testing of Roadway Luminaires” 3.5 IES-LM-79, “Electrical & Photometric Measurements of Solid-State Lighting Products” 3.6 GB/T 7002-1986,“Luminosity Test of Flood Luminaires” 3.7 GB/T 9467-1988, “Luminosity Test of Indoor Luminaires” 3.8 GB/T 9468-1988, “Luminosity Test of Street Luminaires” 3.9 IES 61341 “Method of Measurement of Center Beam Intensity and Beam Angle(s) of Reflector Lamp” 3.10 CIE Pub.NO.76, “Photometry-the CIE System of Physical Photometry” 8. Typical oversea market customers: ----------------------------------------------------------- There are many world famous company and lab institute choose Lisun Goniophtometer, Please get the reference customers’ information from Lisun Group Oversea Sales Dept. 9. Application Software This system can export data files as following formats: This kind of format files can be transferred by other illumination and luminaire design software such as DiaLux Application software can also implement essential calculation for lighting design as iso-illuminance distribution curve on a working plane, luminance limitation curve, luminaire efficiency, effective beam angle, upward luminous flux ratio, downward luminous flux ratio, effective luminous flux, utilization factor curve etc.
  • 8. Moving Detector Goniospectroradiometer (LSG-3000CCD) Brochure Global Office of Lisun Electronics Inc. http://www.Lisungroup.com Lisun Group (Hong Kong) Limited Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon, Hong Kong Tel: 00852-68852050 Fax: 00852-30785638 Email: SalesHK@Lisungroup.com Lisun Electronics (Shanghai) Co., Ltd Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading District, Shanghai, 201802, China Tel: +86(21)5108 3341 Fax: +86(21)5108 3342 Email: SalesSH@Lisungroup.com Lisun Sales Rep Office (USA) Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A. Email: Sales@Lisungroup.com Lisun China Factory Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China Tel: +86-189-1799-6096 Email: Engineering@Lisungroup.com Lead in CFL & LED Test Instruments
  • 9. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 1 - 1. System Configuration A. LSG-3000CCD Goniophotometric System:  Goniometric Rotating Console: Famous brand Motor and Angle encoder System to keep the test accuracy. Both Far Field and Near Field Test.  High Reflective Moving Mirror: Special design and produced to keep high reflective value.  Class A Constant Temperature Photo Detector  Cross-beam Laser System for Calibrating  English Measuring Software  Two sets of luminaries Clamps: multi-functions  Oversea Delivery and Packing: all of the instruments and accessories will be packed with Fumigation free three plywood, include the delivery cost to Shanghai sea port B. SLS-100W DC Standard Light Intensity Lamp C. LS2012Digital Power Meter: High Accuracy to measure AC and DC voltage, current, power and power factor, also measure harmonic D. DC3005 CC & CV DC Power Source: DC3005output is 30V/5A, Option can be DC6010 (output is 60V/10A) and DC12010 (output is 120V/10A) E. LSP-500VAS AC Power Source: 500VA AC Power Source F. CASE-19IN 19inch Standard Instruments Cabinet. G. High Precision CCD Spectraidomeeter H. Accessories and Adjustable Tripod for Spectraidomeeter Full View for LSG-3000CCD Moving Detector Goniospectroradiometer Note: PC and Printer prepared by the customer (request at least three USB ports)
  • 10. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 2 - 2. Measurement Principle LSG-3000CCD Moving Detector Goniospectroradiometer fully meets LM-79 Clause 9.3.1 request. The tested lamp will keep burning position and be fixed, near field detector move together with the big mirror in a line, and the far field detector will move with the big mirror synchronously. The detector will always sense the light directly from the luminaries. The rotation priority is determined by the software. If mirror axle is took precedence of rotation, the goniospectroradiometer will continuously measure the luminous intensity at each γ angle on a vertical plane determined by the C angle, the measuring trace is equivalent to the longitude. Similarly, while the luminaries axle is priority, the system will continuously measure the luminous intensity at each C angle on a conical surface determined by the γ angle, the trace can be looked upon the woof. See the following figure. Measurement Principle 3. System Functions
  • 11. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 3 - LSG-3000CCD Moving Detector Goniospectroradiometer The LSG-3000CCD fully meets LM-79 Clause 9.3.1, CIE and GB standards for Goniophotometric of luminaries, this system is used to measure spatial luminous intensity distribution of luminaries for floodlight, street lighting and interior lighting, and other photometric parameters such as spatial iso-intensity curve, intensity distribution curve of each section (shown in rectangular coordinate system or polar coordinate system), iso-illuminance distribution curve, luminance limitation curve, luminaries efficiency, glare grade, effective beam angles, upward luminous flux ratio, downward luminous flux ratio, total luminous flux, effective luminous flux, utilization factor and electric parameters (wattage, power factor, voltage and current) of luminaries etc. The measured data may be saved in formats IES, LDT (Eulumdat), CIB, TM4, CIE, CEN and CSV for application software of lighting calculation and reflector design. LSG-3000CCD Can test all of the above luminaires 4. Specifications 1) The mirror rotates around the tested luminaire with an angle of (γ)±180° and the tested luminaire rotates around itself with an angle of (C)±180° 2) The accuracy of angle: 0.1° 3) Luminosity Testing Range: Illuminance 0.001lx~99,999lx; Light Intensity 1.0cd~107 cd(detector) 4) Accuracy of photometry: CIE Class A or Class L (option) 5) Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1% 6) Work with high accuracy and quick CCD Spectroradiometer to measure spatial color parameters. 7) Accuracy of chromaticity coordinate: ±0.0015 or ±0.0005(under standard A lamp) 8) Spectral Range Wavelength: 380nm ~780nm; Accuracy of wavelength: ±0.5nm 9) English version software can run in Win7, Win8 or Win10
  • 12. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 4 - 5. Laboratory Requirements 1) Room Requirements according to CIE A. Dark Room: 3*3*8~30m (W*H*L) B. Operating Room: 3*3m (W*L)  The dark room wall, ceiling and floor should be all coated with dull black paint or be covered by black cloth and black carpet.  Air-conditioner: be set in the dark room to control the temperature around lamps to the standard value upon the CIE requirements. Note: LISUN GROUP engineer dept will submit the Lab Design support documents according to the customer’s real lab size after the formal purchase order was confirmed Model Number LSG-3000ACCD LSG-3000BCCD Measure Size (mm) Diameter=600 Diameter=1000 Measure Weight (Kg) 20 30 Measure Power(W) 600V/10A, AC/DC 600V/10A, AC/DC
  • 13. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 5 - 2) Requirements of Eliminating the stray Light Luminaires must be where the photodetector can only receive the light reflected by the two moving mirror in the LSG-3000CCD system. The light given off directly by the luminaries and reflected by the wall and floor is warded off by the light fence. Internal surface of the dark room and dark path together with the surface of the light fence should be painted unpolished black or be covered by black cloth and black carpet. 3) Temperature of the Environment Temperature around the lamp or luminaries must be 25℃±1℃ during the test. Exceptions can be given according to relative lamps as following. a. Tungsten Incandescent Lamp: 25℃±5℃ b. Double-caps Fluorescent Lamp: 25℃±1℃ c. High Pressure Mercury Lamp: 25℃±2℃ d. Metal Halogen Lamp: 25℃±2℃ e. High Pressure Sodium Lamp: 25℃±2℃ f. Low Pressure Sodium Lamp: 25℃±2 4) Airflow Airflow may be induced by natural aeration, air conditioner or movement of the luminaries in the goniophotometer, but the speed of the airflow couldn’t exceed 0.2m/s. 5) Vibration and shock When the lamp is in lighting, the vibration couldn’t exceed 10m/s2(4 ~ 3000Hz), or the moving scope of the lamp couldn’t exceed 30mm (at most 4Hz) 6) Smoke, Dust and Moisture The test environment must free from smoke, dust or moisture. At the same time, even not during the measurement, smoke, dust or moisture will also influence the reflectance of the reflecting mirror and induce more stray light. So, the test room must be kept clean, no smoke and dry. The humidity should be less than 60% RH. 6. Service 1) Installation and Training LISUN GROUP engineers will take responsibility for installation and Training of the system at the customer’s 2) Period of Guarantee: 24 months The service is for free except technician’s travel payment if the service provided by LISUN GROUP implement at the customer’s. 3) Upgrading the applications software for free
  • 14. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 6 - 7. Design Standard of Device The construction, technical parameter, test & operate steps as well as data processing software of LSG-3000CCD Moving Detector Goniospectroradiometer meet the following requirements: 3.1 CIE Pub. NO.70,”The Measurement of Absolute Luminous Intensity Distributions” 3.2 CIE DIV.Ⅱ-TC10,”Photometry of Luminaires” 3.3 IES LM-35-1989,”IES Approved Method for Photometric Testing of Floodlights” 3.4 IES LM-31,”IES Approved Method for Photometric Testing of Roadway Luminaires” 3.5 IES-LM-79, “Electrical & Photometric Measurements of Solid-State Lighting Products” 3.6 GB/T 7002-1986,“Luminosity Test of Flood Luminaires” 3.7 GB/T 9467-1988, “Luminosity Test of Indoor Luminaires” 3.8 GB/T 9468-1988, “Luminosity Test of Street Luminaires” 3.9 IES 61341 “Method of Measurement of Center Beam Intensity and Beam Angle(s) of Reflector Lamp” 3.10 CIE Pub.NO.76, “Photometry-the CIE System of Physical Photometry” 8. Typical oversea market customers: There are many world famous company and lab institute choose Lisun Goniophtometer, Please get the reference customers’ information from Lisun Group Oversea Sales Dept. 9. Application Software This system can export data files as following formats: This kind of format files can be transferred by other illumination and luminaire design software such as DiaLux Application software can also implement essential calculation for lighting design as iso-illuminance distribution curve on a working plane, luminance limitation curve, luminaire efficiency, effective beam angle, upward luminous flux ratio, downward luminous flux ratio, effective luminous flux, utilization factor curve etc.
  • 15. Lisun Electronics Inc. http://www.Lisungroup.com +86(21)51083341 +86(21)51083342 Page 1 Luminaire Property Luminaire Description: LED Down Light Luminaire Categorie: Lamp Categorie: Lamp Description: Number of Lamp: 6 Lamp Lumens(lm): 100 Luminous Length(m): 100 Luminous Width(m): 100 Luminous Height(m): 50 Voltage: 220V Current: 0.029A Power: 5.8W Power Factor: 0.907 Test Lab: Lisun Electronics Inc Photometric Type: Type C Photometric Results CIE Class: Direct Measurement Flux: 412.55 lm Efficiency: 68.76% Central Intensity: 184.785cd Max. Intensity: 184.785cd Max.Intensity Angle: C:0.0 G:0.0 Beam Angle(50%Imax): L: -47.7 R:45.8 Luminaire Efficacy Rating(LER) : 71.13 lm/W Upward Ratio: 0.0% Downward Ratio: 100.0% Field Angle(10%Imax): Left: -73.7 Right:72.5 C0/C180 90°° 45° 60° 184.8 147.8 110.9 73.9 37.0 -180° 180°0° cd 37.0 73.9 110.9 147.8 184.8 cd -180° 180°0° cd 37.0 73.9 110.9 147.8 184.8 cd C90/270 90°° 45° 60° 184.8 147.8 110.9 73.9 37.0 -180° 180°0° cd 37.0 73.9 110.9 147.8 184.8 cd -180° 180°0° cd 37.0 73.9 110.9 147.8 184.8 cd Equipment:LSG-3000 Date:2018-05-31 Operator:zhang Test Report: Test Distance:0.941m Temperature:25 Humidity:65%
  • 16. Lisun Electronics Inc. http://www.Lisungroup.com +86(21)51083341 +86(21)51083342 Page 2 Light intensity data Unit[cd] CG G0.0 G5.0 G10.0 G15.0 G20.0 G25.0 G30.0 G35.0 G40.0 G45.0 C0.0 184.8 183.4 181.6 176.5 169.7 158.6 145.2 129.7 112.7 95.2 C90.0 184.8 184.3 183.2 180.3 174.2 164.7 152.2 136.6 119.6 101.9 C180.0 184.8 184.3 183.2 180.3 174.2 164.7 152.2 136.6 119.6 101.9 C270.0 184.8 183.4 181.6 176.5 169.7 158.6 145.2 129.7 112.7 95.2 C360.0 184.8 183.4 181.6 176.5 169.7 158.6 145.2 129.7 112.7 95.2 CG G50.0 G55.0 G60.0 G65.0 G70.0 G75.0 G80.0 G85.0 G90.0 G95.0 C0.0 77.8 61.8 47.0 35.0 23.5 13.3 2.2 0.0 0.0 0.0 C90.0 84.1 67.0 51.7 37.9 26.4 15.7 7.7 0.6 0.0 0.0 C180.0 84.1 67.0 51.7 37.9 26.4 15.7 7.7 0.6 0.0 0.0 C270.0 77.8 61.8 47.0 35.0 23.5 13.3 2.2 0.0 0.0 0.0 C360.0 77.8 61.8 47.0 35.0 23.5 13.3 2.2 0.0 0.0 0.0 CG G100.0 G105.0 G110.0 G115.0 G120.0 G125.0 G130.0 G135.0 G140.0 G145.0 C0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C90.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C180.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C270.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C360.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 CG G150.0 G155.0 G160.0 G165.0 G170.0 G175.0 G180.0 C0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C90.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C180.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C270.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C360.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Equipment:LSG-3000 Date:2018-05-31 Operator:zhang Test Report: Test Distance:0.941m Temperature:25 Humidity:65%
  • 17. Lisun Electronics Inc. http://www.Lisungroup.com +86(21)51083341 +86(21)51083342 Page 3 Isolx curve Height: 1 m 3.3 3.3 2.7 2.7 2.0 2.0 1.3 1.3 0.7 0.7 0.0 0.0 0.7 0.7 1.3 1.3 2.0 2.0 2.7 2.7 3.3 3.3 0.0 (10%): 18.5lx (20%): 37.lx (30%): 55.4lx (40%): 73.9lx (50%): 92.4lx (60%): 110.9lx (70%): 129.4lx (80%): 147.8lx (90%): 166.3lx (100%): 184.6lx Equipment:LSG-3000 Date:2018-05-31 Operator:zhang Test Report: Test Distance:0.941m Temperature:25 Humidity:65%
  • 18. Lisun Electronics Inc. http://www.Lisungroup.com +86(21)51083341 +86(21)51083342 Page 4 Space Isolx Curve (10%): 18.5lx (20%): 37.lx (30%): 55.4lx (40%): 73.9lx (50%): 92.4lx (60%): 110.9lx (70%): 129.4lx (80%): 147.8lx (90%): 166.3lx (100%): 184.6lx Equipment:LSG-3000 Date:2018-05-31 Operator:zhang Test Report: Test Distance:0.941m Temperature:25 Humidity:65%
  • 19. Lisun Electronics Inc. http://www.Lisungroup.com +86(21)51083341 +86(21)51083342 Page 5 Luminance Limitting Curve Diameter: 0mm Length: 0mm Width: 888mm Height: 0mm G(°) 85 75 65 55 45 6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4 (cd/m2) 2 3 4 6 8 a / hs a b c d e f g h Lum. Limitting Curve (C0/C90) Glare Quality Service Values Illuminance (lx) 1.15 A 2000 1000 500 ≤300 1.5 B 2000 1000 500 ≤300 1.85 C 2000 1000 500 ≤300 2.2 D 2000 1000 500 ≤300 2.55 E 2000 1000 500 ≤300 (cd/m2) γ C0 C90 45° 50° 55° 60° 65° 70° 75° 80° 85° C0: C90: 3367 3604 3024 3271 2693 2922 2350 2587 2069 2241 1718 1931 1286 1519 322 1112 Equipment:LSG-3000 Date:2018-05-31 Operator:zhang Test Report: Test Distance:0.941m Temperature:25 Humidity:65%
  • 20. Lisun Electronics Inc. http://www.Lisungroup.com +86(21)51083341 +86(21)51083342 Page 6 Cofficiencts of Utilization RHOCC RHOW RCR 0 1 2 3 4 5 6 7 8 9 10 080 70 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 COEFFCIENTS OF UTILIZATION FOR RHOFC=20 1.19 1.19 1.19 1.16 1.16 1.16 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.00 1.08 1.06 1.05 1.06 1.05 1.03 1.02 1.01 0.99 0.97 0.95 0.94 0.91 0.89 0.87 0.82 0.94 0.92 0.90 0.93 0.90 0.88 0.90 0.87 0.85 0.87 0.83 0.80 0.82 0.78 0.75 0.70 0.82 0.79 0.78 0.82 0.78 0.76 0.80 0.76 0.73 0.77 0.73 0.69 0.74 0.69 0.65 0.61 0.72 0.69 0.68 0.72 0.69 0.66 0.71 0.67 0.63 0.69 0.64 0.60 0.67 0.61 0.57 0.53 0.64 0.61 0.59 0.64 0.61 0.58 0.64 0.59 0.56 0.63 0.57 0.53 0.61 0.55 0.50 0.46 0.57 0.54 0.53 0.57 0.54 0.52 0.57 0.53 0.49 0.57 0.51 0.47 0.56 0.50 0.45 0.41 0.51 0.49 0.47 0.52 0.48 0.46 0.52 0.48 0.44 0.52 0.46 0.42 0.51 0.45 0.40 0.37 0.46 0.44 0.42 0.47 0.44 0.42 0.48 0.43 0.40 0.48 0.42 0.38 0.47 0.41 0.36 0.33 0.42 0.40 0.39 0.43 0.40 0.38 0.44 0.39 0.36 0.44 0.39 0.35 0.44 0.38 0.33 0.30 0.39 0.36 0.35 0.39 0.36 0.34 0.40 0.36 0.33 0.41 0.35 0.32 0.41 0.35 0.30 0.27 Equipment:LSG-3000 Date:2018-05-31 Operator:zhang Test Report: Test Distance:0.941m Temperature:25 Humidity:65%
  • 21. 1 2 3 4 5 6 7 8 9 10 20 40 60 80 100 [m2] 200 400 600 800 1 2 3 4 5 6 7 8 9 10 [N] 10 20 30 40 2m 6m 10m 2m 4m 6m 8m 10m Budgetary Estimate Light Flux 412.55lm M_Factor 0.8/0.8 Aver LX 100lx Plane H 0 Place C W F Reflect1 0.7 0.5 0.2 Reflect2 0.5 0.3 0.2 Indoor Budgetary Estimate Chart Lisun Electronics Inc. http://www.Lisungroup.com +86(21)51083341 +86(21)51083342 Page 7 Equipment:LSG-3000 Date:2018-05-31 Operator:zhang Test Report: Test Distance:0.941m Temperature:25 Humidity:65%
  • 22. Lisun Electronics Inc. http://www.Lisungroup.com +86(21)51083341 +86(21)51083342 Page 8 UGR Glare Index Ceiling 70 70 50 50 30 70 70 50 50 30 Wall 50 30 50 30 30 50 30 50 30 30 Floor 20 20 20 20 20 20 20 20 20 20 Room Size Weft to light axis direction of observation Direction of light axis parallel observation X Y 2H 2H 14.7 16.0 14.9 15.9 16.5 14.7 15.9 14.8 16.0 16.5 3H 16.3 17.4 16.7 17.9 17.9 16.2 17.4 16.4 17.8 18.0 4H 16.9 18.1 17.4 18.7 18.8 16.9 18.1 17.3 18.5 18.8 6H 17.6 18.5 18.0 18.9 18.9 17.4 18.3 17.8 18.9 19.0 8H 17.8 18.9 18.1 19.0 19.3 17.7 18.7 17.9 19.0 19.3 12H 17.9 18.8 18.1 19.2 19.5 17.7 18.7 18.1 19.2 19.6 4H 2H 15.7 16.6 15.9 16.8 17.0 15.6 16.6 15.8 16.9 17.0 3H 17.5 18.4 17.7 18.4 18.8 17.3 18.2 17.6 18.3 18.7 4H 18.3 18.9 18.5 19.1 19.5 18.0 18.9 18.4 19.1 19.6 6H 18.8 19.5 19.1 19.8 20.2 18.7 19.5 18.9 19.7 20.0 8H 19.0 19.7 19.4 20.0 20.3 19.0 19.5 19.3 20.0 20.3 12H 19.2 19.8 19.7 20.0 20.5 19.1 19.8 19.5 20.1 20.5 8H 4H 18.5 19.2 18.8 19.4 19.8 18.5 19.1 18.7 19.4 19.8 6H 19.3 19.8 19.8 20.2 20.6 19.2 19.7 19.6 20.2 20.5 8H 19.8 20.2 20.2 20.5 20.9 19.6 20.0 20.1 20.4 21.0 12H 20.0 20.4 20.4 20.9 21.1 19.8 20.3 20.3 20.8 21.2 12H 4H 18.6 19.2 19.1 19.6 19.8 18.5 19.0 18.9 19.4 19.8 6H 19.5 20.0 19.9 20.2 20.7 19.4 19.9 19.8 20.2 20.6 8H 19.9 20.3 20.4 20.5 21.1 19.8 20.2 20.3 20.6 21.0 Equipment:LSG-3000 Date:2018-05-31 Operator:zhang Test Report: Test Distance:0.941m Temperature:25 Humidity:65%
  • 23. GC 0 90 x y Tc Ra x y Tc Ra 0 0.1937 0.3104 6958 73.9 0.1944 0.3109 6856 74.2 10 0.1938 0.3105 6942 73.8 0.1939 0.3104 6940 73.9 20 0.1938 0.3112 6872 73.7 0.1938 0.3108 6912 73.8 30 0.1936 0.3120 6804 73.5 0.1938 0.3112 6872 73.6 40 0.1932 0.3130 6738 73.2 0.1933 0.3119 6836 73.2 50 0.1929 0.3137 6686 72.9 0.1932 0.3126 6772 73.1 60 0.1925 0.3144 6658 72.6 0.1928 0.3133 6740 72.7 70 0.1918 0.3148 6662 72.0 0.1921 0.3138 6734 72.1 80 0.1910 0.3153 6666 71.1 0.1921 0.3149 6634 71.7 90 0.1917 0.3174 6442 66.7 0.1911 0.3159 6614 68.6 100 0.2035 0.3274 5176 40.1 0.2054 0.3264 5134 40.3 110 0.2014 0.3260 5352 44.0 0.2036 0.3248 5304 42.2 120 0.2005 0.3252 5436 47.0 0.2021 0.3258 5326 45.1 130 0.2006 0.3248 5452 47.9 0.1999 0.3244 5510 47.9 140 0.1983 0.3232 5662 49.3 0.1980 0.3237 5650 51.0 150 0.1993 0.3228 5636 49.7 0.1977 0.3227 5728 50.6 160 0.2003 0.3239 5518 45.6 0.1959 0.3230 5804 50.5 170 0.2011 0.3238 5484 43.7 0.1978 0.3251 5576 45.3 180 0.2064 0.3252 5146 35.1 0.2080 0.3260 5026 35.7 The inhomogeneity of Chromaticity:△u=0.0147 △v=0.01423