www.ucontrol.com.au - Find the best range of ATR243 controllers comes in three versions. Refer to the table below to easily select your preferred model.
The document provides an overview of the SmartLine conventional fire detection control panel. The panel can manage up to 20 or 36 detection zones depending on the model. Each zone connects to up to 30 fire detection devices and has an additional configurable input/output. The panel outputs signals for alarms and faults. It supports up to 4 repeater panels and an optional gas extinguishing board. The zones accommodate various fire and gas detectors as well as call points to detect and locate fires.
1. The document introduces ETA's PCBA coating line products, including coating machines, loaders/unloaders, conveyors, IR ovens, and UV curing ovens.
2. It provides specifications for several models of each machine type, such as number of nozzles, axis numbers, PCB size limits, speeds, temperatures, dimensions, and power requirements.
3. The document lists some customers that use ETA's special ovens for applications like component testing and verification, automotive battery module glue curing, and material testing.
The document describes two universal I/O modules, the TXM1.8U and TXM1.8U-ML. Both modules have 8 inputs/outputs that can be individually configured as digital inputs, analog inputs, or analog outputs. The TXM1.8U-ML additionally includes an LCD display and local override facility. The modules have compact DIN rail housing, LED status indicators, and terminal bases that allow easy wiring and replacement of modules without rewiring.
VAISALA MHT410 HYDROGEN+MOISTURE-IN-OIL TRANSMITTER NA PRODUCT ORDER GUIDE AN...Ricky Henderson
The Vaisala MHT410 transmitter provides online monitoring of moisture, hydrogen, and temperature in power transformer oil. It has unique probe design that directly measures these parameters from the oil without pumps or membranes. This provides accurate real-time data to monitor transformer health and enable proactive maintenance to minimize outages. The transmitter has isolated outputs, IP66 housing, and 5 year warranty.
This document provides a user manual for an ultrasonic level meter. It includes 3 sections:
1. An introduction that outlines the meter's features such as its precision, non-contact design, and ability to connect to displays and DCS systems.
2. Technical specifications including a measuring range of 0-15m, accuracy of 0.3%, analog and digital output options, and operating temperature range.
3. Installation instructions covering the external dimensions, wiring, definitions of installation parameters, principles, and precautions. It provides diagrams of how the meter works and defines terms like mounting height and blind area.
Detectomat Fire Alarm Systems in India by Monshermonsher123
Monsher brings you the technologically advanced Detectomat Fire Alarm Systems in India by collaborating with the German giant Jobs Group, that has earned VDS approval and controls 98% of the world’s sprinkler production. For more information, visit us at: http://monsher.com/product.html
Chip module initialization machine PTM-120BPIOTEC CHINA
Welcome to Contact Us!
inquiry@piotec.cn
Product Description:
PTM-120B is an upgrade product designed for the increasing production requirement of chip encapsulation & testing factories and smart card manufacturers. The brand-new design enables operators to switch chips production between 6PIN and 8PIN within 60 seconds.
It integrates short-circuit punching, open and short test, chip initialization & pre-personalization as well as reject chip punching and marking. Modular design can meet your different production requirements and maximize decreasing your investment cost.
PTM-120B can be applied to contact/contactless and dual interface chip initialization, and also can be customized according to the demands for various chip production.
The document provides information on the Mercury TM1500P PCB-Mount Digital Encoders from Electromate, including specifications for the encoders, available scales, and ordering information. The Mercury 1500P encoder is a small, digital output encoder designed for mounting directly onto printed circuit boards. It is available with either linear or rotary sensing and offers resolutions down to 0.5 microns with various scale length and diameter options.
The document provides an overview of the SmartLine conventional fire detection control panel. The panel can manage up to 20 or 36 detection zones depending on the model. Each zone connects to up to 30 fire detection devices and has an additional configurable input/output. The panel outputs signals for alarms and faults. It supports up to 4 repeater panels and an optional gas extinguishing board. The zones accommodate various fire and gas detectors as well as call points to detect and locate fires.
1. The document introduces ETA's PCBA coating line products, including coating machines, loaders/unloaders, conveyors, IR ovens, and UV curing ovens.
2. It provides specifications for several models of each machine type, such as number of nozzles, axis numbers, PCB size limits, speeds, temperatures, dimensions, and power requirements.
3. The document lists some customers that use ETA's special ovens for applications like component testing and verification, automotive battery module glue curing, and material testing.
The document describes two universal I/O modules, the TXM1.8U and TXM1.8U-ML. Both modules have 8 inputs/outputs that can be individually configured as digital inputs, analog inputs, or analog outputs. The TXM1.8U-ML additionally includes an LCD display and local override facility. The modules have compact DIN rail housing, LED status indicators, and terminal bases that allow easy wiring and replacement of modules without rewiring.
VAISALA MHT410 HYDROGEN+MOISTURE-IN-OIL TRANSMITTER NA PRODUCT ORDER GUIDE AN...Ricky Henderson
The Vaisala MHT410 transmitter provides online monitoring of moisture, hydrogen, and temperature in power transformer oil. It has unique probe design that directly measures these parameters from the oil without pumps or membranes. This provides accurate real-time data to monitor transformer health and enable proactive maintenance to minimize outages. The transmitter has isolated outputs, IP66 housing, and 5 year warranty.
This document provides a user manual for an ultrasonic level meter. It includes 3 sections:
1. An introduction that outlines the meter's features such as its precision, non-contact design, and ability to connect to displays and DCS systems.
2. Technical specifications including a measuring range of 0-15m, accuracy of 0.3%, analog and digital output options, and operating temperature range.
3. Installation instructions covering the external dimensions, wiring, definitions of installation parameters, principles, and precautions. It provides diagrams of how the meter works and defines terms like mounting height and blind area.
Detectomat Fire Alarm Systems in India by Monshermonsher123
Monsher brings you the technologically advanced Detectomat Fire Alarm Systems in India by collaborating with the German giant Jobs Group, that has earned VDS approval and controls 98% of the world’s sprinkler production. For more information, visit us at: http://monsher.com/product.html
Chip module initialization machine PTM-120BPIOTEC CHINA
Welcome to Contact Us!
inquiry@piotec.cn
Product Description:
PTM-120B is an upgrade product designed for the increasing production requirement of chip encapsulation & testing factories and smart card manufacturers. The brand-new design enables operators to switch chips production between 6PIN and 8PIN within 60 seconds.
It integrates short-circuit punching, open and short test, chip initialization & pre-personalization as well as reject chip punching and marking. Modular design can meet your different production requirements and maximize decreasing your investment cost.
PTM-120B can be applied to contact/contactless and dual interface chip initialization, and also can be customized according to the demands for various chip production.
The document provides information on the Mercury TM1500P PCB-Mount Digital Encoders from Electromate, including specifications for the encoders, available scales, and ordering information. The Mercury 1500P encoder is a small, digital output encoder designed for mounting directly onto printed circuit boards. It is available with either linear or rotary sensing and offers resolutions down to 0.5 microns with various scale length and diameter options.
Hydraulic Electro Hydraulic Training SetFaruk Kartal
Hydraulic and electrohydraulic training set using for hydraulic training. It contains 12 different unit that replaceable in below.
1. Training panel
2. Drawer unit
3. Input module
4. Buttons and signal lamps module
5. Relays module
6. Time relay module
7. Counter module
8. Motor module (DC motor, stepping motor, encoder)
9. PLC module (SIEMENS S7 1200)
10. Proportional directional control valve module
11. Proportional pressure control valve module
This document provides specifications for various biometric access control devices produced by CINT. It includes fingerprint time and attendance machines, access control terminals that support fingerprint, card, and password authentication. The models vary in supported users from 500-30,000, transaction logs from 50,000-1,00,000, dimensions, battery backup options, and connectivity including TCP/IP, USB, and WiFi. Features include fast fingerprint matching speeds below 1 second, durable optical sensors, and graphical interfaces.
Catalog bộ điều khiển nhiệt độ (Digital Temperature Controller) PXR - Beeteco...Beeteco
Catalog bộ điều khiển nhiệt độ (Digital Temperature Controller) PXR Fuji Electric
Beeteco.com là trang mua sắm trực tuyến thiết bị điện - Tự động hóa uy tín tại Việt Nam.
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Địa chỉ : Số 7/31 KDC Thương Mại Sóng Thần, KP. Nhị Đồng 1, P. Dĩ An, Tx. Dĩ An, Tỉnh Bình Dương
FB: www.facebook.com/beeteco
Email: contact@beeteco.com
Tel: 0650 3617 012
Hotline: 0909.41.61.43
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Boiler or other burner combustion efficiency can by improved through the addition of intelligent and accurate control devices that carefully regulate fuel air mixture through the use of parallel positioning of valves and dampers. Additional safety and efficiency functions can be incorporated into the control system include burner sequencing, ignition and flame monitoring protection. Boiler lead/lag control is also available.
Data Teknis Gossen Metrawatt Special Multimeter : METRAHIT PM TECH, METRAHIT PM XTRA, METRAHIT EBASE, METRAHIT ETECH, METRAHIT EXTRA, METRAHIT ESPECIAL, METRAHIT EU PRO
Pemesanan produk, hubungi PT Siwali Swantika melalui WhatsApp, Jakarta : 0811-1519-949 (chat only) | Surabaya : 0811-1519-948 (chat only). Kunjungi website kami di www.siwali.com, untuk detail informasi spesifikasi dan model alat.
Micronics U1000-HM Clamp On Ultrasonic Heat Meter - User ManualThorne & Derrick UK
This document is the user manual for the Micronics U1000-HM Clamp On Ultrasonic Heat Meter. It provides instructions on installing and operating the heat meter, which uses ultrasonic sensors to measure flow rate and temperature sensors to calculate energy transfer. The manual describes how to mount the sensors to the pipe, enter parameters, view readings and access password protected menus to change settings. It also provides specifications, default values, error messages and declarations of conformity for the U1000-HM heat meter.
The document describes the Mercury TM3500V vacuum rated smart encoder. It has programmable interpolation in integer steps down to 5 nanometers and is rated for use down to 10-8 Torr vacuum. It has high resolution for both linear and rotary scales. The encoder has small sensor size, easy alignment, and high performance making it well-suited for applications requiring operation in vacuum environments.
The CAL range of temperature controllers are designed to be easy to use, low cost and reliable in the most demanding applications, including plastics, packaging, drying and laboratory equipment.
Proline Promag 50P, 53P-Electromagnetic Flowmeter. Flow measurement of liquids in chemical or process applications. Email: lam.nguyen@vietan-enviro.com HP: 0945 293292
The document is a catalog for battery operated magnetic flow meters. It provides an overview of the RBEFB series battery powered electromagnetic flow meters, which are designed for water resource and industrial applications without power supply. The meters can achieve accuracy levels of 1.0%, 0.5% or 0.2% and feature micro-power design, lithium batteries with 3-6 year lifespan, LCD display, self-diagnostics, RS485 communication and optional GSM/GPRS remote monitoring software. The catalog describes the technical specifications, model selection guidelines, dimensions, display, measurement error curve and applications of the flow meters.
The document discusses Seneca's CANopen distributed I/O system solution. It provides an overview of Seneca's digital and analog I/O modules that directly connect to the CANopen network without needing additional couplers. The modules offer features like fast response times, accuracy, multiple configuration options, and isolation. Traditional I/O systems require couplers that increase costs, while Seneca's distributed solution reduces wiring and allows flexible placement of I/O nodes on the network.
This document provides information on the Mercury TM3000V vacuum rated smart encoder. It can achieve resolutions down to 0.020um for linear scales and 16.8 million counts per revolution for rotary scales. The encoder sensor is rated for vacuum environments down to 10-8 Torr and features programmable interpolation, compact size, and easy alignment. The document includes details on specifications, outputs, electronics, scales and ordering information.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
1.4Megapixel Metal Vari-focal AHD camera with 40M IR distance included bracke...TTBVS
This document provides specifications for an outdoor security camera. The camera has a 1.3 megapixel CMOS sensor, includes 42 infrared LEDs for night vision up to 40 meters, and has a 2.8-12mm vari-focal lens. Additional details include support for PAL/NTSC standards, a maximum video transmission distance of 300 meters, automatic IR-cut filter, and operating temperature range of -10 to 55 degrees Celsius.
Fireye PPC4000, the newest member of the Nexus family, is a state of the art parallel positioning system for all types of liquid or gaseous fuel fired combustion systems.
This document provides specifications for an EtherCAT servo drive called the REL. It can operate in various control modes including position, velocity, and torque control. It communicates via EtherCAT and has inputs and outputs including digital and analog I/O. It supports various feedback devices including encoders. Safety features include redundant enable inputs and overvoltage and overtemperature protection.
Features:
Self Adjusting Tracking Radar Programmable (recommended) and Simple push-button calibration Output 4-20 mA/ 20-4mA (Isolated on 4 Wire Model's only ) Optional RS232 OR RS485 For communications with calibration diagnostics & data logging software PL Compatible (Modbus RTU) Three or four Wire Operation
Application:
1) Food and Beverages Water / Wastewater Chemicals with vapors
2) Solids with Dust Powder
Mechanical:
Conduit Entry : 1/2" NPT x 2
Enclosure : Aluminum or S.S-94V0
Ingress Protection : NEMA4 (IP65)Type 4/4X
Environmental:
Temperature : -40to 140 F (-40 to 60 C)
Approvals : FCC Part 15 - Low communication device
Installation category: class II
Process:
Temperature PP Rod : - 40 to 176 F (-40 to 80 c)
De-coupler & PTFE Rod - 40 to 350 F(-40 to 177 c)
Material Dielectric : Er >2
Max. Pressure : 5 bar (without De-coupler)
For very dusty applications divide max. range by two.
This document provides operating instructions for the TLK 94, a microprocessor-based digital electronic controller. It describes the controller's functions including ON/OFF, PID, and motorized actuator control. It also covers installation, configuration, programming, alarms, maintenance and specifications. The controller can measure and control temperature, voltage, or current processes and communicate via RS485. It has 4 setpoint values that can be programmed along with parameters to configure inputs, outputs, control modes and alarms.
Hydraulic Electro Hydraulic Training SetFaruk Kartal
Hydraulic and electrohydraulic training set using for hydraulic training. It contains 12 different unit that replaceable in below.
1. Training panel
2. Drawer unit
3. Input module
4. Buttons and signal lamps module
5. Relays module
6. Time relay module
7. Counter module
8. Motor module (DC motor, stepping motor, encoder)
9. PLC module (SIEMENS S7 1200)
10. Proportional directional control valve module
11. Proportional pressure control valve module
This document provides specifications for various biometric access control devices produced by CINT. It includes fingerprint time and attendance machines, access control terminals that support fingerprint, card, and password authentication. The models vary in supported users from 500-30,000, transaction logs from 50,000-1,00,000, dimensions, battery backup options, and connectivity including TCP/IP, USB, and WiFi. Features include fast fingerprint matching speeds below 1 second, durable optical sensors, and graphical interfaces.
Catalog bộ điều khiển nhiệt độ (Digital Temperature Controller) PXR - Beeteco...Beeteco
Catalog bộ điều khiển nhiệt độ (Digital Temperature Controller) PXR Fuji Electric
Beeteco.com là trang mua sắm trực tuyến thiết bị điện - Tự động hóa uy tín tại Việt Nam.
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Địa chỉ : Số 7/31 KDC Thương Mại Sóng Thần, KP. Nhị Đồng 1, P. Dĩ An, Tx. Dĩ An, Tỉnh Bình Dương
FB: www.facebook.com/beeteco
Email: contact@beeteco.com
Tel: 0650 3617 012
Hotline: 0909.41.61.43
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Boiler or other burner combustion efficiency can by improved through the addition of intelligent and accurate control devices that carefully regulate fuel air mixture through the use of parallel positioning of valves and dampers. Additional safety and efficiency functions can be incorporated into the control system include burner sequencing, ignition and flame monitoring protection. Boiler lead/lag control is also available.
Data Teknis Gossen Metrawatt Special Multimeter : METRAHIT PM TECH, METRAHIT PM XTRA, METRAHIT EBASE, METRAHIT ETECH, METRAHIT EXTRA, METRAHIT ESPECIAL, METRAHIT EU PRO
Pemesanan produk, hubungi PT Siwali Swantika melalui WhatsApp, Jakarta : 0811-1519-949 (chat only) | Surabaya : 0811-1519-948 (chat only). Kunjungi website kami di www.siwali.com, untuk detail informasi spesifikasi dan model alat.
Micronics U1000-HM Clamp On Ultrasonic Heat Meter - User ManualThorne & Derrick UK
This document is the user manual for the Micronics U1000-HM Clamp On Ultrasonic Heat Meter. It provides instructions on installing and operating the heat meter, which uses ultrasonic sensors to measure flow rate and temperature sensors to calculate energy transfer. The manual describes how to mount the sensors to the pipe, enter parameters, view readings and access password protected menus to change settings. It also provides specifications, default values, error messages and declarations of conformity for the U1000-HM heat meter.
The document describes the Mercury TM3500V vacuum rated smart encoder. It has programmable interpolation in integer steps down to 5 nanometers and is rated for use down to 10-8 Torr vacuum. It has high resolution for both linear and rotary scales. The encoder has small sensor size, easy alignment, and high performance making it well-suited for applications requiring operation in vacuum environments.
The CAL range of temperature controllers are designed to be easy to use, low cost and reliable in the most demanding applications, including plastics, packaging, drying and laboratory equipment.
Proline Promag 50P, 53P-Electromagnetic Flowmeter. Flow measurement of liquids in chemical or process applications. Email: lam.nguyen@vietan-enviro.com HP: 0945 293292
The document is a catalog for battery operated magnetic flow meters. It provides an overview of the RBEFB series battery powered electromagnetic flow meters, which are designed for water resource and industrial applications without power supply. The meters can achieve accuracy levels of 1.0%, 0.5% or 0.2% and feature micro-power design, lithium batteries with 3-6 year lifespan, LCD display, self-diagnostics, RS485 communication and optional GSM/GPRS remote monitoring software. The catalog describes the technical specifications, model selection guidelines, dimensions, display, measurement error curve and applications of the flow meters.
The document discusses Seneca's CANopen distributed I/O system solution. It provides an overview of Seneca's digital and analog I/O modules that directly connect to the CANopen network without needing additional couplers. The modules offer features like fast response times, accuracy, multiple configuration options, and isolation. Traditional I/O systems require couplers that increase costs, while Seneca's distributed solution reduces wiring and allows flexible placement of I/O nodes on the network.
This document provides information on the Mercury TM3000V vacuum rated smart encoder. It can achieve resolutions down to 0.020um for linear scales and 16.8 million counts per revolution for rotary scales. The encoder sensor is rated for vacuum environments down to 10-8 Torr and features programmable interpolation, compact size, and easy alignment. The document includes details on specifications, outputs, electronics, scales and ordering information.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
1.4Megapixel Metal Vari-focal AHD camera with 40M IR distance included bracke...TTBVS
This document provides specifications for an outdoor security camera. The camera has a 1.3 megapixel CMOS sensor, includes 42 infrared LEDs for night vision up to 40 meters, and has a 2.8-12mm vari-focal lens. Additional details include support for PAL/NTSC standards, a maximum video transmission distance of 300 meters, automatic IR-cut filter, and operating temperature range of -10 to 55 degrees Celsius.
Fireye PPC4000, the newest member of the Nexus family, is a state of the art parallel positioning system for all types of liquid or gaseous fuel fired combustion systems.
This document provides specifications for an EtherCAT servo drive called the REL. It can operate in various control modes including position, velocity, and torque control. It communicates via EtherCAT and has inputs and outputs including digital and analog I/O. It supports various feedback devices including encoders. Safety features include redundant enable inputs and overvoltage and overtemperature protection.
Features:
Self Adjusting Tracking Radar Programmable (recommended) and Simple push-button calibration Output 4-20 mA/ 20-4mA (Isolated on 4 Wire Model's only ) Optional RS232 OR RS485 For communications with calibration diagnostics & data logging software PL Compatible (Modbus RTU) Three or four Wire Operation
Application:
1) Food and Beverages Water / Wastewater Chemicals with vapors
2) Solids with Dust Powder
Mechanical:
Conduit Entry : 1/2" NPT x 2
Enclosure : Aluminum or S.S-94V0
Ingress Protection : NEMA4 (IP65)Type 4/4X
Environmental:
Temperature : -40to 140 F (-40 to 60 C)
Approvals : FCC Part 15 - Low communication device
Installation category: class II
Process:
Temperature PP Rod : - 40 to 176 F (-40 to 80 c)
De-coupler & PTFE Rod - 40 to 350 F(-40 to 177 c)
Material Dielectric : Er >2
Max. Pressure : 5 bar (without De-coupler)
For very dusty applications divide max. range by two.
This document provides operating instructions for the TLK 94, a microprocessor-based digital electronic controller. It describes the controller's functions including ON/OFF, PID, and motorized actuator control. It also covers installation, configuration, programming, alarms, maintenance and specifications. The controller can measure and control temperature, voltage, or current processes and communicate via RS485. It has 4 setpoint values that can be programmed along with parameters to configure inputs, outputs, control modes and alarms.
Lack of adequate infrastructure is a significant inhibitor to increased trade of the countries of the Mediterranean region. Bringing their transport infrastructure to standards comparable with countries of a similar per capita GDP will be costly but worthwhile.
We compare the current quantities of six types of transport infrastructure with international, and estimate the additional quantities needed to reach the benchmarks. We also estimate the cost of that infrastructure and express it as a percentage of GDP. Finally we make tentative estimates of how much trade might be generated and how this might impact on GDP. All the estimates are made for each MED11 country and for each of four scenarios.
The highest need for additional infrastructure will be for airport passenger terminals (between 52% and 56%), whereas the lowest need was for more unpaved roads (between 7% and 13%). The investment (including maintenance) cost would be between 0.9% of GDP and 2.4% of GDP, although the investments in some countries would be between 1.4% and 4.5% of GDP.
The impact on non-oil international trade would be substantial, but with differences between imports and exports. The overall trade balance of the MED11 region would be an improvement of between 5.4% and 17.2%, although some countries would continue to have a negative balance.
A final assessment was of the benefit ratio between the increase in GDP and the cost of transport investment. This varied between about 3 and 8, an indication of the high return to be expected from increased investment in transport infrastructure.
Written by Robin Carruthers. Published in April 2012
Catalogul lunii octombrie 2011 a fost lansat! Rasfoieste-l si intra pe www.dmail.ro pentru cumparaturi avantajoase: transport gratuit pentru comenzi mai mari de 250 lei + voucher in valoare de 40 lei! Intra chiar ACUM.
The document is a 2014 research report from the Canadian Light Source Inc. (CLS). It provides an overview of research conducted in 2014 including 10 highlighted publications covering topics in chemical and materials science, life sciences, earth and environmental science, and instrumentation techniques. It also describes innovations at CLS including industrial science programs, the Medical Isotopes Project, and student involvement. The report outlines CLS's funding partners and key events in 2014 such as staff changes and research highlights.
SNEC (www.snec.ro/romania) este un proiect care asigura sondarea calitativa si cantitativa a pietei de comert electronic din Romania. Initiativa a fost pornita in 2004 si este condusa de Claudiu Gamulescu si Adrian Zamfira.
O galego na rede: gústanos (II). Irimia, nº 848Román Landín
Artigo publicado para o número 848 (do 6 ao 26 de febreiro de 2012) da revista Irimia: http://asociacion-irimia.org/. Tamén en Irimegos: http://irimegos.wordpress.com/
The document provides information about financial goal planning and retirement. It discusses the importance of prioritizing goals such as protection against death, a happy retirement, and providing a better future for children. It recommends creating a reserve fund and savings plan using the 4C formula of creation, consumption, conservation, and continuation of income. Tables show projected costs of living and education expenses over time under inflation. The document stresses the importance of starting to save early in order to afford retirement and children's education without burdening them later in life.
My last vacations involved traveling by bus early in the morning to Anolaima, Colombia. Upon arriving at an estate, the group walked around, cooked a roast for a meal consisting of meat, sausage, potatoes, plantains and avocado, and danced. They explored the area, picking fruits, before returning home on the bus later that evening.
Rajagopalan Thinakaran is seeking a challenging career in the mechanical or piping industry. He has over 15 years of experience in inspection, quality control, and project coordination roles. His technical qualifications include welding inspection certifications and experience commissioning systems on offshore rigs and FPSOs. Recently he worked as a Project Coordinator for POSH SEMCO on an offshore vessel pedestal gangway installation project in Saudi Arabia.
El documento presenta una lista de nombres de lugares en Bolivia. Incluye nombres de puentes, ríos, lagos, lagunas y localidades. La lista contiene más de 200 entradas con información sobre la ubicación geográfica.
El documento discute la oposición de algunos generales del ejército venezolano a que Nicolás Maduro sea el sucesor de Hugo Chávez si este no puede asumir la presidencia. Los generales prefieren a Diosdado Cabello. También hay rumores sobre el estado de salud grave de Chávez y la incertidumbre política resultante. Otro tema es la disputa por la candidatura presidencial de la oposición.
Original Advanced IGBT/Mosfet Driver TD350E 350E SOP-14 New ST MicroelectronicsAUTHELECTRONIC
This document provides information on an advanced IGBT/MOSFET gate driver called the TD350E, including its key features, applications, description, and specifications. The TD350E is designed for applications such as inverters, motor control, and UPS systems. It provides 1.5A/2.3A gate drive, active Miller clamping, two-level turn-off protection, desaturation detection, and fault status output. Electrical characteristics and timing diagrams are included to specify the device's performance.
This document provides an overview and specifications for the Q46C2 2-electrode conductivity monitor/analyzer. It includes:
1. General features such as power options, outputs, display, and sensor compatibility.
2. Specifications for measurement ranges, outputs, relays, enclosure, and performance.
3. Instructions for mounting the analyzer including wall/pipe mounting, panel mounting, and sensor mechanicals.
4. Details on electrical installation including power, relay, output, and sensor connections.
5. Description of the user interface and software including menus, calibration, PID control, and diagnostics.
6. Information on system configuration, maintenance, calibration procedures, spare parts,
This document provides information on an electromagnetic water meter catalog from RB Flowmeter, including:
- An overview of the RBEFB-LS battery powered electromagnetic flow meter and its features such as long battery life, LCD display, IP68 protection, and remote monitoring software.
- The main technical parameters including measurement ranges, accuracy levels, materials, and communication interfaces.
- Details on model selection including pipe size, flange rating, materials, and configuration options.
- Dimensions, tables of specifications, descriptions of the display, interface, software system and applications for water supply, treatment and distribution networks.
The document provides instructions for installing and connecting a KINAX 3W2 transmitter that converts angular position to a current signal. It describes the transmitter's components, mounting options, electrical connections, and technical specifications. The transmitter can be directly mounted or attached with clips and aligned so its zero point matches the measured component. Wiring must match the transmitter's nameplate and not exceed maximum load resistance. Proper installation and use ensures safe and accurate angular measurement.
The document provides instructions for installing and connecting a KINAX 3W2 transmitter that converts angular position to a current signal. It describes the transmitter's components, mounting options, electrical connections, and technical specifications. The transmitter can be directly mounted or attached with clips and aligned so its zero point matches the measured component. Wiring must match the transmitter's nameplate and not exceed maximum load resistance. Proper installation and use ensures safe and accurate angular measurement.
This document provides instruction for using the T601 Multitasker, a 2-channel tachometer that measures frequency and analog signals. It has inputs for 2 speed sensors, 1 analog sensor, and 2 binary inputs. Outputs include 2 analog outputs, 4 relays, and 2 open collectors. The T601 is configured via PC software to measure parameters like speed and temperature. It can monitor sensors, detect speed and direction, and log data. The document provides details on installation, connections, configuration software, operating behavior, and specifications.
Serial 3 Channel AC 230V SSR and DimmerRaghav Shetty
The board can be used in application where dimming of 110-220v AC power is required like dimming of bulb or fan.The board can be control with Serial data from any microcontroller 0-100% dimming or ON/OFF control Main power(230v) completely isolated from microcontroller.
Rotork Instruments, as part of their Fairchild brand, offers a series of electro-pneumatic pressure controllers that have built in PID closed loop microprocessor control utilizing a remote analog or digital setpoint signal. The electronic controller regulates feed and bleed solenoid valves to control pressure in the signal chamber of the booster section. Outlet pressure is measured and used as a feedback signal to the controller to provide accurate control of the outlet pressure. The device functions as a volume booster and I/P transducer.
This document provides product information on STMicroelectronics' TSX561, TSX562, and TSX564 micropower, wide bandwidth (900 kHz), 16 V CMOS operational amplifiers. Key specifications include low power consumption of 235 μA typical at 5 V supply, gain bandwidth product of 900 kHz typical, input offset voltage of 600 μV max for "A" versions and 1 mV max for standard versions, input bias current of 1 pA typical, operating temperature range of -40 to +125 °C, and ESD tolerance of 4 kV. The amplifiers are available in SOT23-5, DFN8, MiniSO8, SO8, QFN16, and TSS
This document provides an operating manual for the KS50-1 and KS52-1 industrial controllers. It describes how to mount and make electrical connections to the controllers, and explains their operation including configuration, parameter settings, calibration, programming, and special functions. Mounting involves fastening the controller housing and setting safety switches for the inputs and outputs. Electrical connections cover power supply, sensor inputs, relay and universal outputs, and optional digital and communication interfaces. Operation involves levels for monitoring, configuration, parameter settings, and calibration. Self-tuning, manual tuning, and PID parameter sets are explained.
This document provides an installation and user manual for the CHOPPER SEM2 electronic speed controller.
It begins with an introduction to the ZAPI-MOS family of speed controllers and their key features including advanced technology, flexibility, safety, and openness to future innovations.
The document then provides details on the technical specifications, control units, safety features, directions, operations, diagnostics, thermal considerations, and instructions for the SEM2 speed controller. It includes sections on installation, programming adjustments, traction applications, diagnostics, spare parts, and maintenance.
The NTE2361 and NTE2362 are complementary silicon transistors designed for high speed switching and general amplifier applications. They have a very high gain allowing them to be driven directly from integrated circuits. Key specifications include a breakdown voltage of 50V, continuous collector current of 500mA, and operating temperature range of -55°C to +150°C.
The STM is an integrated step motor and drive device that combines a step motor and drive electronics into a single unit. This offers space, wiring, and cost savings over separate motor and drive solutions. The STM provides various control modes including pulse and direction, velocity control, and execution of programmed motion sequences. Models are available with different communications interfaces like RS-232, RS-485, and CANopen.
Serial 8 Channel AC 230V SSR and Dimmer Bluetooth InterfaceRaghav Shetty
The board can be used in application where dimming of 110-220v AC power is required like dimming of bulb or fan.The board can be control with Serial data from any microcontroller 0-100% dimming or ON/OFF control Main power(230v) completely isolated from microcontroller.
Receive information on transformer fault situations with reliable and robust online transmitter. The Vaisala Moisture, Hydrogen and Temperature Transmitter MHT410 for Transformer Oil measures directly from representative transformer oil giving both reliable hydrogen trend as well as fast moisture data.
It is built to last and doesn’t have wearing parts such as membrane, pumps, hoses or batteries. Easy to install, the MHT410 is ready to use within minutes. Continuously monitoring hydrogen and moisture levels with an in-situ probe is the first step in extending the life of a transformer through implementation of predictive maintenance practices leading to lower total cost of ownership.
Liquipoint t ftw31 32 endress+hauser datasheet-level limit switch for multipl...ENVIMART
Liquipoint t ftw31 32 endress+hauser datasheet-level limit switch for multiple point - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
This manual will assist you in installing, using and maintaining your Zero Instrument flow meter. It is your responsibility to make sure that all operators have access to adequate instructions about safe operating and maintenance procedure.
This document provides information on STM32F100x4, STM32F100x6, STM32F100x8, and STM32F100xB microcontrollers. It describes their key features such as an ARM Cortex-M3 CPU, Flash memory ranging from 16 to 128KB, SRAM from 4 to 8KB, timers, ADC, DAC, communication interfaces, and low power modes. It also provides detailed specifications on electrical parameters, pinouts, memory mapping, and packaging information.
Building Production Ready Search Pipelines with Spark and MilvusZilliz
Spark is the widely used ETL tool for processing, indexing and ingesting data to serving stack for search. Milvus is the production-ready open-source vector database. In this talk we will show how to use Spark to process unstructured data to extract vector representations, and push the vectors to Milvus vector database for search serving.
Fueling AI with Great Data with Airbyte WebinarZilliz
This talk will focus on how to collect data from a variety of sources, leveraging this data for RAG and other GenAI use cases, and finally charting your course to productionalization.
In the rapidly evolving landscape of technologies, XML continues to play a vital role in structuring, storing, and transporting data across diverse systems. The recent advancements in artificial intelligence (AI) present new methodologies for enhancing XML development workflows, introducing efficiency, automation, and intelligent capabilities. This presentation will outline the scope and perspective of utilizing AI in XML development. The potential benefits and the possible pitfalls will be highlighted, providing a balanced view of the subject.
We will explore the capabilities of AI in understanding XML markup languages and autonomously creating structured XML content. Additionally, we will examine the capacity of AI to enrich plain text with appropriate XML markup. Practical examples and methodological guidelines will be provided to elucidate how AI can be effectively prompted to interpret and generate accurate XML markup.
Further emphasis will be placed on the role of AI in developing XSLT, or schemas such as XSD and Schematron. We will address the techniques and strategies adopted to create prompts for generating code, explaining code, or refactoring the code, and the results achieved.
The discussion will extend to how AI can be used to transform XML content. In particular, the focus will be on the use of AI XPath extension functions in XSLT, Schematron, Schematron Quick Fixes, or for XML content refactoring.
The presentation aims to deliver a comprehensive overview of AI usage in XML development, providing attendees with the necessary knowledge to make informed decisions. Whether you’re at the early stages of adopting AI or considering integrating it in advanced XML development, this presentation will cover all levels of expertise.
By highlighting the potential advantages and challenges of integrating AI with XML development tools and languages, the presentation seeks to inspire thoughtful conversation around the future of XML development. We’ll not only delve into the technical aspects of AI-powered XML development but also discuss practical implications and possible future directions.
Removing Uninteresting Bytes in Software FuzzingAftab Hussain
Imagine a world where software fuzzing, the process of mutating bytes in test seeds to uncover hidden and erroneous program behaviors, becomes faster and more effective. A lot depends on the initial seeds, which can significantly dictate the trajectory of a fuzzing campaign, particularly in terms of how long it takes to uncover interesting behaviour in your code. We introduce DIAR, a technique designed to speedup fuzzing campaigns by pinpointing and eliminating those uninteresting bytes in the seeds. Picture this: instead of wasting valuable resources on meaningless mutations in large, bloated seeds, DIAR removes the unnecessary bytes, streamlining the entire process.
In this work, we equipped AFL, a popular fuzzer, with DIAR and examined two critical Linux libraries -- Libxml's xmllint, a tool for parsing xml documents, and Binutil's readelf, an essential debugging and security analysis command-line tool used to display detailed information about ELF (Executable and Linkable Format). Our preliminary results show that AFL+DIAR does not only discover new paths more quickly but also achieves higher coverage overall. This work thus showcases how starting with lean and optimized seeds can lead to faster, more comprehensive fuzzing campaigns -- and DIAR helps you find such seeds.
- These are slides of the talk given at IEEE International Conference on Software Testing Verification and Validation Workshop, ICSTW 2022.
“An Outlook of the Ongoing and Future Relationship between Blockchain Technologies and Process-aware Information Systems.” Invited talk at the joint workshop on Blockchain for Information Systems (BC4IS) and Blockchain for Trusted Data Sharing (B4TDS), co-located with with the 36th International Conference on Advanced Information Systems Engineering (CAiSE), 3 June 2024, Limassol, Cyprus.
Cosa hanno in comune un mattoncino Lego e la backdoor XZ?Speck&Tech
ABSTRACT: A prima vista, un mattoncino Lego e la backdoor XZ potrebbero avere in comune il fatto di essere entrambi blocchi di costruzione, o dipendenze di progetti creativi e software. La realtà è che un mattoncino Lego e il caso della backdoor XZ hanno molto di più di tutto ciò in comune.
Partecipate alla presentazione per immergervi in una storia di interoperabilità, standard e formati aperti, per poi discutere del ruolo importante che i contributori hanno in una comunità open source sostenibile.
BIO: Sostenitrice del software libero e dei formati standard e aperti. È stata un membro attivo dei progetti Fedora e openSUSE e ha co-fondato l'Associazione LibreItalia dove è stata coinvolta in diversi eventi, migrazioni e formazione relativi a LibreOffice. In precedenza ha lavorato a migrazioni e corsi di formazione su LibreOffice per diverse amministrazioni pubbliche e privati. Da gennaio 2020 lavora in SUSE come Software Release Engineer per Uyuni e SUSE Manager e quando non segue la sua passione per i computer e per Geeko coltiva la sua curiosità per l'astronomia (da cui deriva il suo nickname deneb_alpha).
Let's Integrate MuleSoft RPA, COMPOSER, APM with AWS IDP along with Slackshyamraj55
Discover the seamless integration of RPA (Robotic Process Automation), COMPOSER, and APM with AWS IDP enhanced with Slack notifications. Explore how these technologies converge to streamline workflows, optimize performance, and ensure secure access, all while leveraging the power of AWS IDP and real-time communication via Slack notifications.
Unlock the Future of Search with MongoDB Atlas_ Vector Search Unleashed.pdfMalak Abu Hammad
Discover how MongoDB Atlas and vector search technology can revolutionize your application's search capabilities. This comprehensive presentation covers:
* What is Vector Search?
* Importance and benefits of vector search
* Practical use cases across various industries
* Step-by-step implementation guide
* Live demos with code snippets
* Enhancing LLM capabilities with vector search
* Best practices and optimization strategies
Perfect for developers, AI enthusiasts, and tech leaders. Learn how to leverage MongoDB Atlas to deliver highly relevant, context-aware search results, transforming your data retrieval process. Stay ahead in tech innovation and maximize the potential of your applications.
#MongoDB #VectorSearch #AI #SemanticSearch #TechInnovation #DataScience #LLM #MachineLearning #SearchTechnology
Unlocking Productivity: Leveraging the Potential of Copilot in Microsoft 365, a presentation by Christoforos Vlachos, Senior Solutions Manager – Modern Workplace, Uni Systems
AI 101: An Introduction to the Basics and Impact of Artificial IntelligenceIndexBug
Imagine a world where machines not only perform tasks but also learn, adapt, and make decisions. This is the promise of Artificial Intelligence (AI), a technology that's not just enhancing our lives but revolutionizing entire industries.
Essentials of Automations: The Art of Triggers and Actions in FMESafe Software
In this second installment of our Essentials of Automations webinar series, we’ll explore the landscape of triggers and actions, guiding you through the nuances of authoring and adapting workspaces for seamless automations. Gain an understanding of the full spectrum of triggers and actions available in FME, empowering you to enhance your workspaces for efficient automation.
We’ll kick things off by showcasing the most commonly used event-based triggers, introducing you to various automation workflows like manual triggers, schedules, directory watchers, and more. Plus, see how these elements play out in real scenarios.
Whether you’re tweaking your current setup or building from the ground up, this session will arm you with the tools and insights needed to transform your FME usage into a powerhouse of productivity. Join us to discover effective strategies that simplify complex processes, enhancing your productivity and transforming your data management practices with FME. Let’s turn complexity into clarity and make your workspaces work wonders!
Generating privacy-protected synthetic data using Secludy and MilvusZilliz
During this demo, the founders of Secludy will demonstrate how their system utilizes Milvus to store and manipulate embeddings for generating privacy-protected synthetic data. Their approach not only maintains the confidentiality of the original data but also enhances the utility and scalability of LLMs under privacy constraints. Attendees, including machine learning engineers, data scientists, and data managers, will witness first-hand how Secludy's integration with Milvus empowers organizations to harness the power of LLMs securely and efficiently.
GraphRAG for Life Science to increase LLM accuracyTomaz Bratanic
GraphRAG for life science domain, where you retriever information from biomedical knowledge graphs using LLMs to increase the accuracy and performance of generated answers
Climate Impact of Software Testing at Nordic Testing DaysKari Kakkonen
My slides at Nordic Testing Days 6.6.2024
Climate impact / sustainability of software testing discussed on the talk. ICT and testing must carry their part of global responsibility to help with the climat warming. We can minimize the carbon footprint but we can also have a carbon handprint, a positive impact on the climate. Quality characteristics can be added with sustainability, and then measured continuously. Test environments can be used less, and in smaller scale and on demand. Test techniques can be used in optimizing or minimizing number of tests. Test automation can be used to speed up testing.
Climate Impact of Software Testing at Nordic Testing Days
Regolatore Manuale Instatore
1.
2. Summary
1 Introduction ........................................................................................................ 3
2 Model Identification............................................................................................ 3
3 Technical Data................................................................................................... 4
3.1 General Features........................................................................................ 4
3.2 Hardware Features..................................................................................... 4
3.3 Software Features ...................................................................................... 5
4 Dimensions and Installation............................................................................... 5
4.1 Panel Assembly.......................................................................................... 6
4.2 Electronics Removal................................................................................... 6
5 Electrical wirings................................................................................................ 7
5.1 Wiring diagram ........................................................................................... 7
6 Display and Key Functions .............................................................................. 13
6.1 Numeric Indicators (Display) .................................................................... 13
6.2 Meaning of Status Lights (Led) ................................................................ 13
6.3 Keys.......................................................................................................... 14
7 Controller Functions......................................................................................... 14
7.1 Modifying Main Setpoint and Alarm Setpoint Values ............................... 14
7.2 Auto-Tune................................................................................................. 15
7.3 Manual Tuning.......................................................................................... 15
7.4 Automatic Tuning...................................................................................... 15
7.5 Soft Start................................................................................................... 16
7.6 Automatic/Manual Regulation for % Output Control ................................ 16
7.7 Pre-Programmed Cycle............................................................................ 17
7.8 Memory Card............................................................................................ 18
8 LATCH ON Functions...................................................................................... 19
8.1 Loop Break Alarm On Amperometric Transformer................................... 21
8.2 Digital Input Functions.............................................................................. 22
8.3 Dual Action Heating-Cooling .................................................................... 23
9 Serial Communication...................................................................................... 25
10 Configuration ................................................................................................... 30
10.1 Modify Configuration Parameter............................................................... 30
11 Table of Configuration Parameters.................................................................. 31
12 Alarm Intervention Modes................................................................................ 44
13 Table of Anomaly Signals................................................................................ 49
14 Summary of Configuration parameters............................................................ 50
3. 3
1 Introduction
Thank you for choosing a Pixsys controller.
With the ATR243 model Pixsys makes available in a single device all
the resources relevant to sensor input and actuators command, in
addition to the extended power range 24…230 Vac/Vdc. With 18
sensors to select and outputs configurable as relay, SSR command,
4…20 mA and 0…10Volt, the user or retailer can reduce warehouse
stock by rationalising investment and device availability. The series is
completed with models equipped with serial communication RS485
Modbus RTU and with a loading control function via the amperometric
transformer. The configuration is further simplified by the Memory
cards which are equipped with internal battery and therefore don’t
require cabling to power the controller.
2 Model Identification
The range of ATR243 controllers comes in three versions. Refer to the
table below to easily select your preferred model.
Models available, with power 24…230 Vac/Vdc +/-15% 50/60Hz – 3VA
ATR243-20-ABC 2 relays 5A or 1 relay + 1 Ssr/V/mA
ATR243-21-ABC-T 2 relays 5A + 1 Ssr/V/mA + Rs485 +amperometric
transformer*
ATR243-31-ABC 3 relays 5A + 1 Ssr/V/mA + amperometric
transformer*
* Models with amperometric transformer input for Loop break alarm
function.
4. 4
3 Technical Data
3.1 General Features
Displays 4 0.40 inch displays +
4 0.30 displays
Operating
temperature
0-45°C, humidity 35..95uR%
Sealing IP65 front panel (with gasket)
IP20 casing and terminals
Material PC ABS UL94VO self-extinguishing
Weight 165 g (-20ABC) / 185 g (-21/31ABC)
3.2 Hardware Features
Analogue
input
1: AN1
Configurable via software
Input
Thermocouple type K, S, R, J
Automatic compensation of cold
junction from 0°C to 50°C.
Thermoresistance: PT100,
PT500, PT1000, Ni100, PTC1K,
NTC10K (β 3435K)
Linear: 0-10V, 0-20 or
4-20mA, 0-40mV, amperometric
transformer 50mA, 1024 points on
version ATR243-21/-31
Potentiometers: 6K, 150K,
Tolerance (25°C)
+/-0.2 % ± 1 digit
for thermocouple
input, thermo
resistance and
V/mA.
Cold junction
accuracy 0.1°C/°C
Relay
output
2 relays (Atr243-20...-21…)
3 relays (Atr243-31...)
Configurable as command and/or
alarm output
Contacts 5A-250V~
SSR output 1 linear 0/4…20mA
/SSR/0…10Volt
>deselecting OUT2 relay on
ATR243-20…
Configurable as command output
or retransmission of setpoint or
process.
Configurable:
> 4-20mA,
> 0…10Volt,
> 0-20mA.
Resolution
4000 points
5. 5
3.3 Software Features
Regulation algorithms ON-OFF with hysteresis.
P, PI, PID, PD with proportional time
Proportional band 0...9999°C or °F
Integral time 0,0...999,9 sec (0 excluded)
Derivative time 0,0...999,9 sec (0 excluded)
Controller functions Manual or automatic Tuning, configurable
alarms, protection of command and alarm
setpoints, activation of functions via digital
input, preset cycle with Start/Stop.
4 Dimensions and Installation
122.5 1148
48
45
45
FRONTAL PANEL
CUT-OUT
SUGGESTED THICKNESS
SPESSORE PANNELLO CONSIGLIATO
2-8mm MAX 19mm
DIMA DI
FORATURA
6. 6
4.1 Panel Assembly
Method of panel assembly and fixing of anchorage hooks.
To dismantle, use a screwdriver and slightly force the fixing hooks to
remove them from the fixing guide.
4.2 Electronics Removal
To remove the electronics, grip the front part using the two specific
side ridges.
7. 7
5 Electrical wirings
Although this controller was designed to resist noises in
industrial environments, pease notice following safety
guidelines:
• Separate the feeder line from the power lines.
• Avoid placing near units with remote control switches,
electromagnetic contactors, high powered motors and in all instances
use specific filters.
• Avoid placing near power units, particularly if phase controlled.
5.1 Wiring diagram
The connections are reported below for the three models available.
12345
678910
111314151612
ATR243-20ABC
ATR243-21ABC-T ATR243-31ABC
10
9
8
7
6
5
4
3
2
1
SUPPLY
24...230V
AC/DC
Q1
SSR/V/mA
-
+12
V/A 11
12
13
14
15
16
Q2
Q3
PTC
NTC
PT100
NI100
+12/GND
ID/TA
TC
Q2
10
9
8
7
6
5
4
3
2
1
SUPPLY
24...230V
AC/DC
Q1
SSR/V/mA
-
+12
V/A
PTC
NTC
PT100
NI100
TC
10
9
8
7
6
5
4
3
2
1
SUPPLY
24...230V
AC/DC
Q1
SSR/V/mA
-
TC
+12
V/A 11
12
13
14
15
16
Q2
RS485
PTC
NTC
PT100
NI100
+12/GND
ID/TA
8. 8
Power
Switching power supply with extended range
24…230 Vac/dc ±15% 50/60Hz - 3VA.
AN1 Analogue Input
For thermocouples K, S, R, J.
• Comply with polarity
• For possible extensions, use a compensated
wire and terminals suitable for the
thermocouples used (compensated)
For thermoresistances PT100, NI100
• For the three-wire connection use wires with
the same section
• For the two-wire connection short-circuit
terminals 1 and 3
• Select internal jumper JP3 as in the figure
1
2
3
For linear signals V/mA
• Comply with polarity
• Select internal jumper JP3 as in the figure
If jumpers are not properly selected,
12Vdc are not available on terminal 3 to
power the sensor.
9. 9
Examples of Connection for linear input
For signals 0….10V
Comply with polarity
P:0...100mbar
Pmax:3bar
T:0..70°C
OUT:4...20mA
IN:9...33VDC
For signals 0/4….20mA with three-wire
sensor
Comply with polarity
A=Sensor output
B=Sensor ground
C=Sensor power
P:0...100mbar
Pmax:3bar
T:0..70°C
OUT:4...20mA
IN:9...33VDC
For signals 0/4….20mA with external power
of sensor
Comply with polarity
A=Sensor output
B=Sensor round
P:0...100mbar
Pmax:3bar
T:0..70°C
OUT:4...20mA
IN:9...33VDC
For signals 0/4….20mA with two-wire sensor
Comply with polarity
A=Sensor output
C=Sensor power supply
Serial input
RS485 Modbus RTU communication
10. 10
Relay Q1 Output
Capacity 5A/250V~ for resistive loads
Relay Q2 Output
Capacity 5A/250V~ for resistive loads
For Q2 selected as a relay output, remove
jumpers JP5 and JP7 as indicated in the figure
(Manufacturer configuration).
Connecting a load without removing the
jumpers will permanently damage the
controller
For models ATR243-21ABC-T and ATR243-
31ABC output Q2 is on terminals 14 and 13.
Q2 output for SSR
SSR command output 12V/30mA
Insert JP5 and JP7 and select JP9 as in
the figure to use the SSR output.
11. 11
Q2 Output in mA or in Volt
Linear output in mA configurable using
parameters as command (Parameter )
or retransmission of process-setpoint
(Parameter )
Insert JP5 and JP7 and select JP9 as in
figure to use the output in mA.
Linear output in Volt configurable using
parameters as command (Parameter )
or retransmission of process-setpoint
(Parameter )
Insert JP5 and JP7 and select JP9 as in
figure to use the linear output in Volt.
Q3 Relay Output on ATR243-31ABC
Capacity 5A/250V~ resistive loads
12. 12
Amperometric Transformer Input on ATR243-21ABC-T and
ATR243-31ABC
• Input 50mA for amperometric transformer
• Sampling time 80ms
• Configurable by parameters
Insert JP4 and JP6 as in figure to select
the amperometric transformer input.
Digital Input on ATR243-20ABC
Digital input using parameter .
The use of digital input in this version is possible
only with TC sensors, 0…10V, 0/4…20mA and
0…40mV
Select internal jumper JP3 as in figure.
Digital Input on ATR243-21ABC-T and ATR243-31ABC
Digital input using parameter
Insert JP4 as in figure to select the
digital input.
13. 13
6 Display and Key Functions
1
3
4
8 9 10 5
6
7
2
6.1 Numeric Indicators (Display)
1
Normally displays the process. During the
configuration phase, it displays the parameter
being inserted.
2
Normally displays the setpoint. During the
configuration phase, it displays the parameter
value being inserted.
6.2 Meaning of Status Lights (Led)
3 C 1
C 2
ON when the output command is on. C1 with
relay/SSR/mA/Volt command or C1 (open) and C2
(close) for a motorised valve command.
4 A 1
A 2
A 3
ON when the corresponding alarm is on.
5 MAN ON when the “Manual” function is on.
6 TUN ON when the controller is running an “Autotune” cycle.
7 REM ON when the controller communicates via serial port.
14. 14
6.3 Keys
8 • Allows to increase the main setpoint.
• During the configuration phase, allows to slide
through parameters. Together with the key it
modifies them.
• Pressed after the key it allows to increase the
alarm setpoint.
9 • Allows to decrease the main setpoint.
• During the configuration phase, allows to slide
through parameters. Together with the key it
modifies them.
• Pressed after the key it allows to decrease the
alarm setpoint.
10 • Allows to display the alarm setpoint and runs the
autotuning function.
• Allows to vary the configuration parameters.
7 Controller Functions
7.1 Modifying Main Setpoint and Alarm Setpoint Values
The setpoint value can be changed from the keyboard as follows:
Press Effect Operation
1
or
Value on display 2
changes
Increases or decreases the
main setpoint
2 Visualize alarm
setpoint on display
1
3
o
Value on display 2
changes
Increases or decreases the
alarm set point value
15. 15
7.2 Auto-Tune
The Tuning procedure calculates the controller parameters and can be
manual or automatic according to selection on parameter 57
).
7.3 Manual Tuning
The manual procedure allows the user greater flexibility to decide
when to update PID algorithm work parameters. The procedure can be
activated in two ways.
• By running Tuning from keyboard:
Press the key until display 1 shows the writing with
display 2 showing , press , display 2 shows .
The TUN led switches on and the procedure begins.
• By running Tuning from digital input:
Select on parameter 61 .
On first activation of digital input (commutation on front panel) the
TUN
led switches on and on second activation switches off.
7.4 Automatic Tuning
Automatic tuning activates when the controller is switched on or when
the setpoint is modified to a value over 35%.
To avoid an overshoot, the treshold where the controller calculates the
new PID parameters is determined by the setpoint value minus the
“Set Deviation Tune” ( see Parameter 58 ).
To exit Tuning and leave the PID values unchanged, just press the
key until display 1 shows the writing with the display
showing , press , display 2 shows .
The TUN led switches off and the procedure finishes.
16. 16
7.5 Soft Start
To reach the setpoint the controller can follow a gradient expressed in
units (e.g. degree/hour).
Set the increase value in parameter 62 with the desired
units/hour; only on subsequent activation the controller uses the soft
start function.
Automatic/manual tuning cannot be enabled if the Soft start is active.
7.6 Automatic/Manual Regulation for % Output Control
This function allows you to select automatic functioning or manual
command of the output percentage.
With parameter 60 , you can select two methods.
1. The first selection allows you to enable the
key with the writing on display 1, while
display two shows .
Press the key to show ; it is
now possible, during the process display, to change the
output percentage using the keys and . To return
to automatic mode, using the same procedure, select
on display 2: the MAN led switches off and
functioning returns to automatic mode.
2. The second selection enables the same
functioning, but with two important variants:
• If there is a temporary lack of voltage or after switch-off, the
manual functioning will be maintained as well as the previously
set output percentage value.
• If the sensor breaks during automatic functioning, the controller
moves to manual mode while maintaining the output percentage
command unchanged as generated by the PID immediately
before breakage.
17. 17
7.7 Pre-Programmed Cycle
The pre-programmed cycle function activates by setting or
in parameter 59 .
First option : the controller reaches setpoint1 basing on the
gradient set in parameter 62 , then it reaches maximum power
up to setpoint2. When the process reaches maximum power, this
setpoint is maintained for the time set in parameter 63 . On
expiry, the command output is disabled and the controller displays
.
Time
Setpoint
Setpoint 1
Setpoint 2 Natural
cooling
Hold
Gradient
Max.
power
The cycle starts at each activation of the controller, or via digital input if
it is enabled for this type of functioning (see parameter 61 ).
Second option : start-up is decided only on activation of the
digital input, according to the setting of parameter 61 . On
start-up, the controller reaches setpoint 1 basing on the gradient set in
parameter 62 . When the process reaches this gradient, it is
maintained for the time set in parameter 63 . On expiry, the
command output is disabled and the controller displays .
Time
Setpoint
Natural
cooling
Hold
Setpoint 1
Gradient
18. 18
7.8 Memory Card
Parameters and setpoint values can be duplicated from one controller
to another using the Memory card.
There are two methods:
• With the controller connected to the power supply
Insert the memory card when the controller is off.
On activation display 1 shows and display 2 shows
(Only if the correct values are saved in the memory card). By
pressing the key display 2 shows , then confirm using the
key. The controller loads the new data and starts again.
RED LIGHT: waiting for programming
GREEN LIGHT: done
LED ROSSO: acceso in programmazione
LED VERDE: programmazione eseguita
• With the controller not connected to power supply.
The memory card is equipped with an internal battery with an
autonomy of about 1000 uses.
Insert the memory card and press the programming buttons.
When writing the parameters, the led turns red and on completing the
procedure it changes to green. It is possible to repeat the procedure
without any particular attention.
19. 19
Updating Memory Card
To update the memory card values, follow the procedure described in
the first method, setting display 2 to so as not to load the
parameters on controller2
.
Enter configuration and change at least one parameter.
Exit configuration. Changes are saved automatically.
8 LATCH ON Functions
For use with input (potentiometer 6K) and
(potentiometer 150K ) and with linear input (0…10V, 0...40mV,
0/4…20mA), you can associate start value of the scale (parameter 6
) to the minimum position of the sensor and value of the scale
end (parameter 7 ) to the maximum position of the sensor
(parameter 8 configured as ).
It is also possible to fix the point in which the controller will display 0
(however keeping the scale range between and )
using the “virtual zero” option by setting or in
parameter 8 . If you set the virtual zero will reset after
each activation of the tool; if you set the virtual zero remains
fixed once tuned.
To use the LATCH ON function configure as you wish the parameter
.3
2
If on activation the controller does not display it means no data have been
saved on the memory card, but it is possible to update values.
3
The tuning procedure starts by exiting the configuration after changing the parameter.
20. 20
For the calibration procedure refer to the following table:
Press Effect Operation
1 Exit parameters
configuration. Display 2
shows the writing .
Position the sensor on the
minimum functioning value
(associated with )
2 Set the value to minimum.
The display shows
Position the sensor on the
maximum functioning
position (associated with
)
3 Set the value to maximum.
The display shows
To exit the standard
procedure press .
For “virtual zero” settings
position the sensor on the
zero point.
4 Set the virtual zero value.
The display shows
N.B.: for selection of
the procedure in
point 4 should be followed
on each re-activation.
To exit the procedure press
.
MAX
MIN ZERO
21. 21
8.1 Loop Break Alarm On Amperometric Transformer
This function allows to measure load current and to manage an alarm
during malfunctioning with power in short circuit or always off. The
amperometric transformer connected to terminals 15 and 16 must be
50mA (sampling time 80ms).
• Set scale end value of the amperometric transformer in Amperes
on parameter 47
• Set the intervention threshold of the Loop break alarm in Amperes
on parameter 48
• Set the intervention delay time of the Loop break alarm on
parameter 49
• You can associate the alarm with a relay by setting the parameter
, or as .
If a remote control switch or SSR remains closed, the controller signals
the fault by showing on display 2 (alternatively with a
command setpoint).
If instead the power stage remains open, or the load current is lower
than the value set on , the controller shows on
display.
You can display the current absorbed during the closure phase of the
power stage.
Press Effect Operation
1 This key enables to scroll
on display 2 the output
percentage, auto/man
selection, setpoint and
alarms.
Press until the writing
appears on
display 1 and display 2
shows the current in
amperes ( >0).
The value is also
maintained when no
current circulates on the
load.
22. 22
8.2 Digital Input Functions
Digital input is programmable for several functions which are useful to
simplify controller operability. Select the desired function on parameter
62 .
1. Hold function (enabled by setting or ) allows to
lock the reading of sensors when the digital input is active
(useful for wide ranging oscillation on less significant values).
During the lock phase, display 2 flashes and shows .
2. Enables/disables the autotuning function from digital input if the
parameter is set on .
3. Enable regulation with or .
4. Switch from automatic to manual functioning if is set
on or .
5. Start of pre-programmed cycle (see paragraph 7.7) with
.
6. Change setpoint function.
This function is useful where there are 2 to 4 working thresholds
required during system functioning without having to press the
arrow keys.
To enable the function use the parameter , by
selecting the number of setpoints desired (no. thresholds
switch). They can be switched during functioning by pressing
the key.
N.B.:
The digital input functions are not available with sensors PT100 and
NI100 on model ATR243-20ABC.
23. 23
8.3 Dual Action Heating-Cooling
ATR243 is also suitable also for systems requiring a combined heating-
cooling action.
The command output must be configured as Heating PID
( = and with a greater than 0), and one of the
alarms ( , or ) must be configured as .
The command output must be connected to the actuator responsible
for heat, while the alarm will control cooling action.
The parameters to configure for the Heating PID are:
= Command output type (Heating)
: Heating proportional band
: Integral time of heating and cooling
: Derivative time of heating and cooling
: Heating time cycle
The parameters to configure for the Cooling PID are the following
(example: action associated to alarm1):
= Alarm1 selection (cooling)
: Proportional band multiplier
: Overlapping/Dead band
: Cooling time cycle
The parameter (that ranges from 1.00 to 5.00) determines the
proportional band of cooling basing on the formula:
Cooling proportional band = *
This gives a proportional band for cooling which will be the same as
heating band if = 1.00, or 5 times greater if = 5.00.
The integral time and derivative time are the same for both actions.
The parameter determines the percentage overlapping
between the two actions. For systems in which the heating output and
cooling output must never be simultaneously active a dead band
( ≤ 0) must be configured, and vice versa you can configure an
overlapping ( > 0).
24. 24
The following figure shows an example of dual action PID (heating-
cooling) with = 0 and = 0.
ACTIVE
ACTIVE
COMMAND OUTPUT (HEAT)
ALARM OUTPUT (COOL)
SPV
PV
< 0
ACTIVE
ACTIVE
(HEAT)
* (COOL)
SPV
PV
COMMAND OUTPUT (HEAT)
ALARM OUTPUT (COOL)
COMMAND OUTPUT (HEAT)
ALARM OUTPUT (COOL)
SPV
PV
ACTIVE
ACTIVE
< 0
(HEAT)
* (COOL)
< 0
(HEAT)
* (COOL)
25. 25
The parameter has the same meaning as the heating time
cycle .
The parameter (cooling fluid) pre-selects the proportional
band multiplier and the cooling PID time cycle basing
on the type of cooling fluid:
Cooling fluid type
Air 1.00 10
Oil 1.25 4
Water 2.50 2
Once selected, the parameter , the parameters ,
and can however be changed.
9 Serial Communication
ATR243-21ABC-T, equipped with RS485, can receive and broadcast
data via serial communication using MODBUS RTU protocol. The
device can only be configured as a Slave. This function enables the
control of multiple controllers connected to a supervisory system
(SCADA).
Each controller responds to a master query only if the query contains
the same address as that in the parameter . The addresses
permitted range from 1 to 254 and there must not be controllers with
the same address on the same line.
Address 255 can be used by the master to communicate with all the
connected equipment (broadcast mode), while with 0 all the devices
receive the command, but no response is expected.
ATR243 can introduce a delay (in milliseconds) in the response to the
master request. This delay must be set on parameter 72
Each parameter change is saved by the controller in the EEPROM
memory (100000 writing cycles), while the setpoints are saved with a
delay of ten seconds after the last change.
NB: Changes made to words that are different from those reported in
the following table can lead to malfunction.
26. 26
Modbus RTU protocol features
Baud-rate Can be selected on parameter 70
4800bit/sec
9600bit/sec
19200bit/sec
28800bit/sec
38400bit/sec
57600bit/sec
Format 8, N, 1 (8bit, no parity, 1 stop)
Supported
functions
WORD READING (max 20 word) (0x03, 0x04)
SINGLE WORD WRITING (0x06)
MULTIPLE WORDS WRITING (max 20 word)
(0x10)
The list below includes all the available addresses, where:
RO = Read Only
R/W = Read/Write
WO = Write Only
27. 27
Modbus
address
Description Read
Write
Reset
value
0 Device type RO EEPROM
1 Software version RO EEPROM
5 Slave Address R/W EEPROM
6 Boot version RO EEPROM
50 Automatic addressing WO -
51 System code comparison WO -
1000 Process (with tenths of degree for temperature
sensors; digits for linear sensors)
RO ?
1001 Setpoint1 R/W EEPROM
1002 Setpoint2 R/W EEPROM
1003 Setpoint3 R/W EEPROM
1004 Setpoint4 R/W EEPROM
1005 Alarm1 R/W EEPROM
1006 Alarm2 R/W EEPROM
1007 Alarm3 R/W EEPROM
1008 Setpoint gradient RO EEPROM
1009 Relay status (0=off, 1=on)
Bit 0 = Q1 relay
Bit 1 = Q2 relay
Bit 2 = reserved
Bit 3 = SSR
RO 0
1010 Heating output percentage
(0-10000)
RO 0
1011 Cooling output percentage
(0-10000)
RO 0
1012 Alarms status (0=none, 1=active)
Bit0 = Alarm 1
Bit1 = Alarm 2
RO 0
1013 Manual reset: write 0 to reset all the alarms.
In reading (0=not resettable, 1=resettable):
Bit0 = Alarm 1
Bit1 = Alarm 2
WO 0
1014 Error flags
Bit0 = Eeprom writing error
Bit1 = Eeprom reading error
Bit2 = Cold junction error
Bit3 = Process error (sensor)
Bit4 = Generic error
Bit5 = Hardware error
Bit6 = L.B.A.O. error
Bit7 = L.B.A.C. error
RO 0
1015 Cold junction temperature (tenths of degree) RO ?
28. 28
1016 Start/Stop
0=controller in STOP
1=controller in START
R/W 0
1017 Lock conversion ON/OFF
0=Lock conversion off
1=Lock conversion on
R/W 0
1018 Tuning ON/OFF
0=Tuning off
1=Tuning on
R/W 0
1019 Automatic/manual selection
0=automatic
1=manual
R/W 0
1020 TA Current ON (amperes to tenths) RO ?
1021 TA Current OFF (ampere to tenths) RO ?
1022 OFF LINE
1
time (milliseconds) R/W 0
1023 Instant Current (Ampere) RO 0
2001 Parameter 1 R/W EEPROM
2002 Parameter 2 R/W EEPROM
... ... ... ...
2072 Parameter 72 R/W EEPROM
3000 Disabling serial control of machine
2
WO 0
3001 First word display1 (ASCII) R/W 0
3002 Second word display1 (ASCII) R/W 0
3003 Third word display1 (ASCII) R/W 0
3004 Fourth word display1 (ASCII) R/W 0
3005 Fifth word display1 (ASCII) R/W 0
3006 Sixth word display1 (ASCII) R/W 0
3007 Seventh word display1 (ASCII) R/W 0
3008 Eighth word display1 (ASCII) R/W 0
3009 First word display2 (ASCII) R/W 0
3010 Second word display2 (ASCII) R/W 0
3011 Third word display2 (ASCII) R/W 0
3012 Fourth word display2 (ASCII) R/W 0
3013 Fifth word display2 (ASCII) R/W 0
3014 Sixth word display2 (ASCII) R/W 0
3015 Seventh display2 (ASCII) R/W 0
3016 Eighth word display2 (ASCII) R/W 0
1
If value is 0, the control is disabled. If different from 0, it is the max. time which can
elapse between two pollings before the controller goes off-line.
If it goes off-line, the controller returns to Stop mode, the control output is disabled
but the alarms are active.
2
By writing 1 on this word, the effects of the writing are cancelled on all the Modbus
addresses from 3001 to 3022. Control therefore returns to the controller.
29. 29
3017 Word LED
Bit 0 = LED C1
Bit 1 = LED C2
Bit 2 = LED A1
Bit 3 = LED A2
Bit 4 = LED A3
Bit 5 = LED MAN
Bit 6 = LED TUN
Bit 7 = LED REM
R/W 0
3018 Word keys
(write 1 to command keys)
Bit 0 =
Bit 1 =
Bit 2 =
R/W 0
3019 Word serial relay
Bit 0 = Q1 relay
Bit 1 = Q2 relay
R/W 0
3020 Word SSR serial (0=off, 1=on) R/W 0
3021 Word output 0...10V serial (0…10000) R/W 0
3022 Word output 4...20mA serial (0…10000) R/W 0
30. 30
10 Configuration
10.1 Modify Configuration Parameter
For configuration parameters see paragraph 11.
Press Effect Operation
1
for 3
seconds.
Display 1 shows
with the 1st
digit flashing, while
display 2 shows
.
2
or
Change the flashing digit
and move to the next
one using the key.
Enter password
3
to confirm
Display 1 shows the first
parameter and display 2
shows the value.
4
or
Slide up/down through
parameters
5
+
or
Increase or decrease the
value displayed by
pressing firstly and
then an arrow key.
Enter the new data which
will be saved on
releasing the keys.
To change another
parameter return to point
4.
6
+
Simultaneou
sly
End of configuration
parameter change.
The controller exits from
programming.
31. 31
11 Table of Configuration Parameters
The following table includes all parameters. Some of them will not be
visible on the models which are not provided with relevant hardware
features.
no. Display Parameter description Entering range
1
Command
Output
Select command output
type
Default
(necessary to use retransmission
function)
ATR243-20ABC
COMMAND ALARM 1
Q1 Q2
Q2 Q1
SSR Q1
Q1(opens)
Q2(closes)
-
SSR Q1
SSR Q1
SSR Q1
ATR243-21ABC-T
COMMAND ALARM 1 ALARM 2
Q1 Q2 SSR
Q2 Q1 SSR
SSR Q1 Q2
Q1(opens)
Q2(closes)
SSR -
SSR Q1 Q2
SSR Q1 Q2
SSR Q1 Q2
32. 32
ATR243-31ABC
COMMAND ALARM 1 ALARM 2 ALARM 3
Q1 Q2 Q3 SSR
Q2 Q1 Q3 SSR
SSR Q1 Q2 Q3
Q2(opens)
Q3(closes)
Q1 SSR -
SSR Q1 Q2 Q3
SSR Q1 Q2 Q3
SSR Q1 Q2 Q3
2
Sensor
Analog input
configuration
Only ATR243-21/31ABC
Tc-K -260…1360°C
(Default setting)
Tc-S -40…1760°C
Tc-R -40…1760°C
Tc-J -200…1200°C
PT100 -100…600°C
PT100 -100…140°C
NI100 -60…180°C
NTC10K -40…125°C
PTC1K -50…150°C
PT500 -100…600°C
PT1000 -100…600°C
0…10Volt
0…20mA
4…20mA
0…40mVolt
Potentiometer
max 6Kohm
Potentiometer
max 150Kohm
50mA secondary
amperometric transformer
Select number of
displayed decimal points Default
33. 33
3 Decimal Point
4
Lower Limit
Setpoint
Lower limit setpoint -999…+9999 digit∗
(degrees if temperature)
Default: 0.
5
Upper Limit
Setpoint
Upper limit setpoint -999…+9999 digit*
(degrees if temperature)
Default: 1750.
6
Lower Linear
Input
Lower range limit An1
only for linear input
-999…+9999 digit*
Default: 0.
7
Upper Linear
Input
Upper range limit An1
only for linear input
-999…+9999 digit*
Default: 1000.
8
Latch On
Function
Automatic setting of limits
for Linear input (Disabled) Default
(Standard)
(Virtual Zero Stored)
(Virtual Zero Initialized)
9
Offset
Calibration
Offset calibration
Number added to
displayed value of
process (normally
corrects the room
temperature value)
-999…+1000 digit* for linear sensors
and potentiometers.
-200.0…+100.0 tenths for
temperature sensors.
Default: 0.0.
10
Gain
Calibration
Gain calibration
Value multiplied with
process value to perform
calibration on working
point
-10.0%…+10.0%
Default: 0.0.
11
Action type
Regulation type
: Heating (N.O.) Default
: Cooling (N.C.)
: HEat Off Over Setpoint
12
Command
Reset
Type of reset for state of
command contact
(always automatic in PID
functioning)
(Automatic Reset) Default
(Manual Reset)
(Manual Reset Stored)
∗
The display of the decimal point depends on the setting of parameter
and the parameter .
34. 34
13
Command
State Error
State of contact for
command output in case
of error
Default
14
Command
Led
State of the OUT1 led
corresponding to the
relevant contact Default
15
Command
Hysteresis
Hysteresis in ON/OFF or
dead band in P.I.D.
-999…+999 digits∗
(tenths of degree if temperature)
Default: 0.0.
16
Command
Delay
Command delay (only in
ON/OFF functioning).
(In case of servo valve it
also functions in PID and
represents the delay
between the opening and
closure of the two
contacts)
-180…+180 seconds (tenths of
second in case of servo valve).
Negative: delay in switching off
phase.
Positive: delay in activation phase.
Default: 0.
17
Command
Setpoint
Protection
Allows or not to change
the command setpoint
value
Default
18
Proportional
Band
Proportional band
Process inertia in units
(E.g.: if temperature is in
°C)
0 on/off if
equal to 0. Default
1-9999 digit* (degrees if
temperature)
19
Integral Time
Integral time. Process
inertia in seconds
0.0-999.9 seconds (0 integral
disabled)
Default: 0.
20
Derivative
Time
Derivative time. Normally
¼ the integral time
0.0-999.9 seconds (0 derivative
disabled)
Default: 0.
21
Cycle Time
Cycle time (for PID on
remote control switch
10/15sec, for PID on
SSR 1 sec) or servo
time (value declared by
servo-motor
manufacturer)
1-300 seconds
Default: 10.
22
Output Power
Limit
Limit of output power % 10-100 %
Default: 100.
∗
The display of the decimal point depends on the setting of parameter
and parameter .
35. 35
23
Alarm 1
Alarm 1 selection.
Intervention of the alarm
is associated with AL1
Only ATR243-21/31ABC
(Disabled) Default
(Absolute Alarm)
(Band Alarm)
(High Deviation Alarm)
(Low Deviation Alarm)
(Absolute Command setpoint Alarm)
(Start Alarm) Active in Run
(Cooling)
(Loop Break Alarm)
24
Alarm 1 State
Output
Alarm 1 output contact
and intervention type (n.o. start) Default
Normally open, active at start
(n.c. start)
Normally closed, active at start
(n.o. threshold)
Normally open, active on reaching
alarm
4
(n.c. threshold)
Normally closed on reaching alarm
4
25
Alarm 1
Reset
Type of Reset for contact
of alarm 1 (Automatic Reset) Default
(Manual Reset)
(Manual Reset Stored)
26
Alarm 1 State
Error
State of contact for alarm
1 output in case of error Default
27
Alarm 1 Led
State of the OUT2 led
corresponding to the
relative contact Default
28
Alarm 1
Hysteresis)
Alarm 1 hysteresis -999…+999 digit∗
(tenths of degree if temperature).
Default: 0.
4
On activation, the output is inhibited if the controller is in alarm mode. Activates only
if alarm condition reappers, after that it was restored.
36. 36
29
Alarm 1 Delay
Alarm 1 delay -180…+180 Seconds
Negative: delay in alarm output
phase.
Positive: delay in alarm entry phase.
Default: 0.
30
Alarm 1
Setpoint
Protection
Alarm 1 set protection.
Does not allow user to
modify setpoint
Default
31
Alarm 2
Alarm 2 selection.
Alarm intervention is
associated with AL2
(Disabled) Default
(Absolute Alarm)
(Band Alarm)
(High Deviation Alarm)
(Low Deviation Alarm)
(Absolute Command setpoint Alarm)
(Start Alarm)
(Cooling)
(Loop Break Alarm)
32
Alarm 2 State
Output
Alarm 2 output contact
and intervention type (n.o. start) Default
Normally open, active at start
(n.c. start)
Normally closed, active at start
(n.o. threshold)
Normally open, active on reaching
alarm
5
(n.c. threshold)
Normally closed, active on reaching
alarm
5
∗
The display of the decimal point depends on the setting of parameter
and parameter .
5
On activation, the output is inhibited if the controller is in alarm mode. It activates
only if alarm condition reappears after that it was restored.
37. 37
33
Alarm 2
Reset
Type of Reset for contact
of alarm 2 (Automatic Reset)
Default
(Manual Reset)
(Manual Reset Stored)
34
Alarm 2 State
Error
State of contact for alarm
2 output in case of error Default
35
Alarm 2 Led
State of OUT2 led
corresponding to relative
contact Default
36
Alarm 2
Hysteresis
Alarm 2 hysteresis -999…+999 digit∗
(tenths of degree if temperature).
Default: 0.
37
Alarm 2 Delay
Alarm 2 delay -180…+180 Seconds
Negative: delay in alarm output
phase.
Positive: delay in alarm entry phase.
Default: 0.
38
Alarm 2
Setpoint
Protection
Alarm 2 set protection.
Does not allow operator
to change value of
setpoint
Default
39
Alarm 3
Alarm 3 selection.
Alarm intervention is
associated with AL3
(Disabled) Default
(Absolute Alarm)
(Band Alarm)
(High Deviation Alarm)
(Low Deviation Alarm)
(Absolute Command setpoint Alarm)
(Start Alarm)
(Cooling)
∗
The display of the decimal point depends on the setting of parameter
and parameter .
38. 38
(Loop Break Alarm)
40
Alarm 3 State
Output
Alarm 3 output contact
and intervention type (n.o. start) Default
Normally open, active at start
(n.c. start)
Normally closed, active at start
(n.o. threshold)
Normally open, active on reaching
alarm
6
(n.c. threshold)
Normally closed, active on reaching
alarm
6
41
Alarm 3
Reset
Type of Reset for contact
of alarm 3 (Automatic Reset) Default
(Manual Reset)
(Manual Reset Stored)
42
Alarm 3 State
Error
State of contact for alarm
3 output in case of error Default
43
Alarm 3 Led
Defines the state of
OUT3 led corresponding
to the relative contact Default
44
Alarm 3
Hysteresis
Alarm 3 hysteresis -999…+999 digit∗
(tenths of degree if temperature).
Default: 0.
45
Alarm 3 Delay
Alarm 3 delay -180…+180 Seconds
Negative: delay in alarm output
phase.
Positive: delay in alarm entry phase.
Default: 0.
46
Alarm 3
Setpoint
Protection
Alarm 3 set protection.
Does not allow the
operator to change the
value of setpoint
Default
47 Activation and scale of
amperometric
0 Disabled
1-200 Ampere
6
On activation, the output is inhibited if the controller is in alarm mode. It activates
only if alarm condition reappears after that it was restored.
∗
The display of the decimal point depends on the setting of parameter
and parameter .
39. 39
Amperometric
Transformer
transformer Default: 0.
48
Loop Break
Alarm
Threshold
Intervention threshold of
Loop break alarm
0.0-200.0 Ampere
Default: 50.0.
49
(Loop Break
Alarm Delay)
Delay time for Loop
break alarm intervention
00.00-60.00 mm.ss
Default: 01.00.
50
Cooling Fluid
Type of cooling fluid
Default
51
Proportional
Band
Multiplier
Proportional band
multiplier
1.00-5.00
Default: 1.00.
52
(Overlap/Dea
d Band)
Overlapping/Dead band -20.0-50.0%
Default: 0.
53
Cooling Cycle
Time
Cycle time for cooling
output
1-300 seconds
Default: 10.
54
Conversion
Filter
ADC filter: number of
means on analog-digital
conversions
(Disabled)
(2 Samples Mean)
(3 Samples Mean)
(4 Samples Mean)
(5 Samples Mean)
(6 Samples Mean)
(7 Samples Mean)
(8 Samples Mean)
(9 Samples Mean)
(10 Samples Mean)
Default
(11 Samples Mean)
(12 Samples Mean)
(13 Samples Mean)
(14 Samples Mean)
40. 40
(15 Samples Mean)
55
Conversion
Frequency
Frequency of sampling of
analog-digital converter (242 Hz)
(123 Hz)
(62 Hz)
(50 Hz)
(39 Hz)
(33.2 Hz)
(19.6 Hz)
(16.7 Hz) Default
(12.5 Hz)
(10 Hz)
(8.33 Hz)
(6.25 Hz)
(4.17 Hz)
56
Visualisation
Filter
Visualisation filter
(Disabled) Default
(First Order)
(2 Samples Mean)
(3 Samples Mean)
(4 Samples Mean)
(5 Samples Mean)
(6 Samples Mean)
(7 Samples Mean)
(8 Samples Mean)
(9 Samples Mean)
(10 Samples Mean)
57
Tune
Tuning type selection
(Disabled) Default
(Automatic)
PID parameters are calculated at
activation and change of set.
(Manual)
Launch from keys or digital input.
41. 41
58
Setpoint
Deviation
Tune
Select the deviation from
the command setpoint,
for the threshold used by
autotuning to calculate
the PID parameters
0-5000 digit∗
(tenths of degree if
temperature).
Default: 10.
59
Operating
Mode
Select operating mode
(Controller) Default
(Programmed Cycle)
(2 Thresholds Switch)
(2 Thresholds Switch
Impulsive)
(3 Thresholds Switch
Impulsive)
(4 Thresholds Switch
Impulsive)
(Time Reset)
(Programmed Cycle
Start/Stop)
60
Automatic /
Manual
Enable automatic/manual
selection (Disabled) Default
(Enabled)
(Enabled Stored)
61
Digital Input
Digital input functioning
(P59 selection must be
or )
(Disabled) Default: 0.
(Start/Stop)
(Run n.o.)
(Run n.c.)
(Lock Conversion n.o.)
(Lock Conversion n.c.)
(Tune) Manual
(Automatic Manual
impulse)
(Automatic Manual
Contact)
∗
The display of the decimal point depends on the setting of the parameter
and the parameter .
42. 42
62
Gradient
Increase gradient for soft
start or pre-programmed
cycle
0 disabled
1-9999 Digit/time∗
(degrees/hours with display of tenths
if temperature)
Default: 0.
63
Maintenance
Time
Maintenance time for
pre-programmed cycle
00.00-24.00 hh.mm
Default: 00.00.
64
User Menu
Cycle
Programmed
Allows the rise gradient
and the maintenance
time to be changed from
the user menu, in pre-
programmed cycle
functioning
(Disabled) Default
(Gradient)
(Maintenance Time)
(All)
65
Visualization
Type
Select visualization for
display 1 and 2 (1 Process, 2 Setpoint) Default
(1 Process, 2 Hide after 3 sec.)
(1 Setpoint, 2 Process)
(1 Setpoint, 2 Hide after 3 sec.)
(1 Process, 2 Ampere.)
66
Degree
Select degree type
: Centigrade
Default
:Fahrenheit
67
Retransmissi
on
Retransmission for
output 0-10V or
4…20mA.
(Select Jumper JP5,
JP7 and JP9).
Parameters 68 and 69
define the lower and
upper limits of the scale.
(Disabled) Default
(Volt Process)
(mA Process)
(Volt Command setpoint)
(mA Command setpoint)
(Volt Output Percentage)
(mA Output Percentage)
(Volt Alarm 1 setpoint)
∗
The display of the decimal point depends on the setting of parameter
and parameter .
43. 43
(mA Alarm 1 setpoint)
(Volt Alarm 2 setpoint)
(mA Alarm 2 setpoint)
(Volt A.T.)
(mA A.T.)
68
Lower Limit
Retransmissi
on
Lower limit range of
linear output
-999…+9999 digit∗
(degrees if
temperature)
Default: 0.
69
Upper Limit
Retransmissi
on
Upper limit range of
linear output
-999…+9999 digit* (degrees if
temperature)
Default: 1000.
70
Baud Rate
Select baud rate for
serial communication
Default
71
Slave
Address
Select slave address for
serial communication
1 – 254
Default: 254.
72
Serial Delay
Select serial delay 0 – 100 milliseconds
Default: 20.
∗
The display of the decimal point depends on the setting of parameter and
parameter .
44. 44
12 Alarm Intervention Modes
Absolute Alarm or Threshold Alarm ( selection)
On On
Off Off
Pv
> 0
Hysteresis
parameter
Time
Alarm
output
Alarm Spv
Absolute alarm with controller
in heating functioning
(Par.11 selected )
and hysteresis value greater
than “0” (Par.28 > 0).
N.B.: The example refers to alarm 1;
the function can also be enabled for
alarms 2 and 3 on models that
include it.
On On
Off Off
Pv
< 0
Hysteresis
parameter
Time
Alarm
output
Alarm Spv
Absolute alarm with controller
in heating functioning
(Par.11 selected )
and hysteresis value less than
“0” (Par.28 < 0).
N.B.: The example refers to alarm 1;
the function can also be enabled for
alarms 2 and 3 on models that
include it.
On On
Off Off
Pv
> 0
Hysteresis
parameter
Time
Alarm
output
Alarm Spv
Absolute alarm with controller
in cooling functioning
(Par.11 selected
) and hysteresis value
greater than “0” (Par.28
> 0).
N.B.: The example refers to alarm 1;
the function can also be enabled for
alarms 2 and 3 on models that
include it.
45. 45
On On
Off Off
Pv
< 0
Hysteresis
parameter
Time
Alarm
output
Alarm Spv
Absolute alarm with controller
in cooling functioning
(Par.11 selected
) and hysteresis value
less than “0” (Par.28 <
0).
N.B.: The example refers to alarm 1;
the function can also be enabled for
alarms 2 and 3 on models that
include it.
Absolute Alarm or Threshold Alarm Referring to Setpoint
Command ( selection)
On
Off Off
Comand Spv
> 0
Hysteresis
parameter
Time
Alarm
output
Alarm Spv
Absolute alarm refers to the
command set, with the
controller in heating
functioning
(Par.11 selected )
and hysteresis value greater
than “0” (Par.28 > 0).
The command set can be
changed by pressing the
arrow keys on front panel or
using serial port RS485
commands.
N.B.: The example refers to alarm 1;
the function can also be enabled for
alarms 2 and 3 on models that
include it.
46. 46
Band Alarm ( selection)
On OnOn
Off OffOff
Pv
Time
Alarm
output
Comand Spv
> 0
Hysteresis
parameter
Alarm Spv
Alarm Spv
Band alarm hysteresis value
greater than “0” (Par.28
> 0).
N.B.: The example refers to alarm 1;
the function can also be enabled for
alarms 2 and 3 on models that
include it.
On On On
Off Off Off
Comand Spv
< 0
Hysteresis
parameter
Pv
Time
Alarm
output
Alarm Spv
< 0
Hysteresis
parameter Band alarm hysteresis value
less than “0” (Par.28 <
0).
N.B.: The example refers to alarm 1;
the function can also be enabled for
alarms 2 and 3 on models that
include it.
47. 47
Upper Deviation Alarm ( selection)
On On
Off Off
Pv
Time
Alarm
output
Comand Spv
> 0
Hysteresis
parameter
Alarm Spv
Upper deviation alarm value of
alarm setpoint greater than “0”
and hysteresis value greater
than “0” (Par.28 > 0).
N.B.:
a) The example refers to alarm 1;
the function can also be enabled for
alarms 2 and 3 on models that
include it.
b) With hysteresis less than “0”
( < 0) the broken line moves
above the alarm setpoint.
On On
Time
Off Off
Alarm
output
Pv
Comand Spv
> 0
Hysteresis
parameter
Alarm Spv
Upper deviation alarm value of
alarm setpoint less than “0”
and hysteresis value greater
than “0” (Par.28 > 0).
N.B.:
a) The example refers to alarm 1;
the function can also be enabled for
alarms 2 and 3 on models that
include it.
b) With hysteresis less than “0”
( < 0) the broken line moves
above the alarm setpoint.
48. 48
Lower Deviation Alarm ( selection)
OnOn
Time
Off Off
Alarm
output
Pv
Comand Spv
> 0
Hysteresis
parameter
Alarm Spv
Lower deviation alarm value of
alarm setpoint greater than “0”
and hysteresis value greater
than “0” (Par.28 > 0).
N.B.:
a) The example refers to alarm 1;
the function can also be enabled for
alarms 2 and 3 on models that
include it.
b) With hysteresis less than “0”
( < 0) the broken line moves
under the alarm setpoint.
On On
Time
Off Off
Comand Spv
Alarm
output
Pv
> 0
Hysteresis
parameter
Alarm Spv
Lower deviation alarm value of
alarm setpoint less than “0”
and hysteresis value greater
than “0” (Par.28 > 0).
N.B.:
a) The example refers to alarm 1;
the function can also be enabled for
alarms 2 and 3 on models that
include it
b) With hysteresis value less than
“0”
( < 0) the broken line moves
under the alarm setpoint.
49. 49
13 Table of Anomaly Signals
In case of malfunctioning of the system, the controller switches off the
regulation output and displays the type of anomaly.
For example the controller will signal the breakage of any connected
thermocouple by displaying (flashing) on display. For other
notifications, see the table below.
# Cause What to do
E-01 Error in E²PROM cell
programming
Call Assistance
E-02 Cold junction sensor fault or room
temperature outside of allowed
limits.
Call Assistance
E-04 Incorrect configuration data.
Possible loss of calibration values.
Check if the configuration parameters
are correct.
E-05 Thermocouple open or
temperature outside of limits.
Check the connection with the
sensors and their integrity.
50. 50
14 Summary of Configuration parameters
Date: Model ATR243:
Installer: System:
Notes:
Command output type selection
Analog input configuration
Number of decimal points
Lower limit setpoint
Upper limit setpoint
Lower limit range An1 only for linear
Upper limit range An1 only for linear
Automatic setting of linear input limits.
Offset calibration
Gain calibration
Regulation type
Command output reset type
Contact state for command output in case of error
Define the OUT1 led state
Hysteresis in ON/OFF or dead band in P.I.D.
Command delay
Command setpoint protection
Proportional band
Integral time
Derivative time
Cycle time
Limit of output power %
Alarm 1 selection
Alarm 1 output contact and intervention type
Reset type of alarm 1 contact.
State of contact for alarm 1 output
State of OUT2 led
51. 51
Alarm 1 hysteresis
Alarm1 delay
Alarm 1 set protection
Alarm 2 selection
Alarm 2 output contact and intervention type
Reset type of alarm 2 contact
State of contact for alarm 2 output
State of OUT2 led
Alarm 2 hysteresis
Alarm 2 delay
Alarm 2 set protection
Alarm 3 selection
Alarm 3 output contact and intervention type
Reset type of alarm 3 contact
State of contact for alarm 3 output
State of OUT3 led
Alarm 3 hysteresis
Alarm 3 delay
Alarm 3 set protection
Activation and scale range of amperometric transformer
Intervention threshold of Loop break alarm
Delay time for Loop break alarm intervention
Cooling fluid type
Proportional band multiplier
Overlapping/Dead band
Cycle time for cooling output
Analog converter filter
Sampling frequency of analog converter
Display filter
Autotuning type selection
Command setpoint deviation for tuning threshold
Operating mode
Automatic/manual selection
52. 52
Digital input functioning
Gradient for soft start
Cycle maintenance time
Gradient change and maintenance time by user
Display data selection
Degree type selection
Retransmission for output 0-10V or 4…20mA
Lower limit range for linear output
Upper limit range for linear output
Select baud rate for serial communication
Select slave address
Select the serial delay