The document describes several power MOSFET devices. It provides key information on their electrical ratings and characteristics including:
- Maximum voltage, current, and power ratings.
- On-resistance, threshold voltage, capacitance values.
- Safe operating area curves and switching/recovery times.
- Package details for TO-220, D2PAK, TO-247, and TO-220FP packages.
A Design Calculation for Single Phase Step Down TransformerIJSRED
This document presents the design calculations for a 10KVA, single phase step-down transformer operating at 50Hz. It describes the design process, including calculating the core dimensions, winding turns and wire sizes. The transformer uses a shell type construction with the primary and secondary windings wound on the central limb. Detailed calculations are shown to determine the core size, window dimensions, winding arrangements and overall transformer dimensions. The design aims to achieve high efficiency to reduce power losses.
This document appears to be a price list from Schneider Electric for its low voltage distribution products. It includes pricing and descriptions for various circuit breakers, switch disconnectors, and accessories. The products are organized by category and range, with sections devoted to Compact NSXm circuit breakers, EasyPact CVS and EZC circuit breakers, ground fault protection devices, Masterpact circuit breakers, and more. Technical specifications, stock statuses, and contact information for ordering are provided.
O documento fornece informações técnicas sobre motores de combustão interna, descrevendo seu funcionamento, principais componentes e possíveis falhas. É dividido em seções tratando de tópicos como pistões, anéis, camisas, válvulas e outros componentes, explicando seu objetivo, tecnologia e causas comuns de falhas precoces.
This document contains design calculations for a single-phase distribution transformer. It specifies design parameters such as a rated output of 50 kVA, primary voltage of 13800V, secondary voltage of 460/230V, and an efficiency of at least 0.96 at full load. The document then shows calculations for transformer components like winding dimensions and currents, core size, flux density, losses, and temperature rise. Design goals are to have losses lower than specified guarantees and a temperature rise under 55°C at full load.
Complete professional technical service and repair manual written for your Mack MP8 Diesel Engine. This is the same type of service manual your local dealer will use when doing a repair. Complete download comes in pdf format which can work under all PC based windows operating system and Mac also. It saves to your hard-drive and can be burned to CD. No scanned-in or bootlegged copy, this manual is made in high resolution, so when you print the pages you need, they are all in great quality!
This document discusses motor protection principles and thermal modeling for motor protection relays. Some key points:
- Motors account for a large portion of electricity usage and failures can be costly. Thermal stress is a major cause of failures.
- A motor protection relay uses a thermal model to monitor the thermal capacity used based on operating conditions like load, ambient temperature, voltage, and current balance. It can trip for overload based on reaching 100% thermal capacity.
- The thermal model considers motor states like running, starting, and overloaded. It uses thermal limit curves, an overload curve, cooling time constants, and a hot to cold stall time ratio in its calculations. Current unbalance is also accounted for through a bias factor.
Design of Three Phase 11000/433 V And 100 KVA TransformerSanjoy Biswas
This document discusses the design of a three-phase 11000/433 V, 100 KVA distribution transformer. It provides an overview of transformer components and design procedures. The design procedure involves selecting the core material as M4 grade with 0.97 stacking factor and 0.27 mm lamination thickness. It aims to optimize design parameters like active part cost, losses, impedance, and tank volume using genetic algorithm techniques. Statistical analysis is carried out to compare results with conventional methods.
A Design Calculation for Single Phase Step Down TransformerIJSRED
This document presents the design calculations for a 10KVA, single phase step-down transformer operating at 50Hz. It describes the design process, including calculating the core dimensions, winding turns and wire sizes. The transformer uses a shell type construction with the primary and secondary windings wound on the central limb. Detailed calculations are shown to determine the core size, window dimensions, winding arrangements and overall transformer dimensions. The design aims to achieve high efficiency to reduce power losses.
This document appears to be a price list from Schneider Electric for its low voltage distribution products. It includes pricing and descriptions for various circuit breakers, switch disconnectors, and accessories. The products are organized by category and range, with sections devoted to Compact NSXm circuit breakers, EasyPact CVS and EZC circuit breakers, ground fault protection devices, Masterpact circuit breakers, and more. Technical specifications, stock statuses, and contact information for ordering are provided.
O documento fornece informações técnicas sobre motores de combustão interna, descrevendo seu funcionamento, principais componentes e possíveis falhas. É dividido em seções tratando de tópicos como pistões, anéis, camisas, válvulas e outros componentes, explicando seu objetivo, tecnologia e causas comuns de falhas precoces.
This document contains design calculations for a single-phase distribution transformer. It specifies design parameters such as a rated output of 50 kVA, primary voltage of 13800V, secondary voltage of 460/230V, and an efficiency of at least 0.96 at full load. The document then shows calculations for transformer components like winding dimensions and currents, core size, flux density, losses, and temperature rise. Design goals are to have losses lower than specified guarantees and a temperature rise under 55°C at full load.
Complete professional technical service and repair manual written for your Mack MP8 Diesel Engine. This is the same type of service manual your local dealer will use when doing a repair. Complete download comes in pdf format which can work under all PC based windows operating system and Mac also. It saves to your hard-drive and can be burned to CD. No scanned-in or bootlegged copy, this manual is made in high resolution, so when you print the pages you need, they are all in great quality!
This document discusses motor protection principles and thermal modeling for motor protection relays. Some key points:
- Motors account for a large portion of electricity usage and failures can be costly. Thermal stress is a major cause of failures.
- A motor protection relay uses a thermal model to monitor the thermal capacity used based on operating conditions like load, ambient temperature, voltage, and current balance. It can trip for overload based on reaching 100% thermal capacity.
- The thermal model considers motor states like running, starting, and overloaded. It uses thermal limit curves, an overload curve, cooling time constants, and a hot to cold stall time ratio in its calculations. Current unbalance is also accounted for through a bias factor.
Design of Three Phase 11000/433 V And 100 KVA TransformerSanjoy Biswas
This document discusses the design of a three-phase 11000/433 V, 100 KVA distribution transformer. It provides an overview of transformer components and design procedures. The design procedure involves selecting the core material as M4 grade with 0.97 stacking factor and 0.27 mm lamination thickness. It aims to optimize design parameters like active part cost, losses, impedance, and tank volume using genetic algorithm techniques. Statistical analysis is carried out to compare results with conventional methods.
That part of power system which distributes electric power for local use is known as DISTRIBUTION.
Electric power distribution is the final stage in the delivery of electricity. Electricity is carried from the transmission system to individual consumers. Distribution substations connect to the transmission system and lower the transmission voltage to medium voltage ranging between 2 kV and 33 kV with the use of transformers. Primary distribution lines carry this medium voltage power to distribution transformers located near the customer's premises. Distribution transformers again lower the voltage to the utilization voltage used by lighting, industrial equipment and household appliances. Often several customers are supplied from one transformer through secondary distribution lines. Commercial and residential customers are connected to the secondary distribution lines through service drops.
This document presents information about Buchholz relays. It discusses that Buchholz relays were first developed in 1921 and are installed in large power transformers to protect against internal faults. The relay contains an upper element that closes an alarm circuit during slow developing faults and a lower element that trips the circuit breaker during severe faults. It operates by detecting hydrogen gas generated from transformer oil decomposition during faults, with the gas causing floats that activate mercury switches to signal alarms or trip the transformer. Buchholz relays provide simple and effective protection for oil-immersed transformers while also detecting slow developing faults earlier than other methods.
This document discusses power transformer energy performance standards and regulations around the world. It covers background topics, common policy instruments used to promote energy efficiency, reference standards used to measure performance, and categories of energy performance metrics. Key points addressed include definitions of rated power, reference temperatures, frequencies and voltages in standards, as well as common metrics like maximum losses, minimum efficiency, and peak efficiency index.
Kioti daedong dk50 tractor service repair manualfjseedcxkmdmme
This document appears to be a chapter from a tractor repair manual. It provides general information about the tractor including views, specifications, identification numbers, and safety cautions for repair. It then details the engine components and systems, including the cylinder head, block, crankshaft, pistons, connecting rod, camshaft, fuel system, lubrication system, cooling system, intake and exhaust systems. It provides a troubleshooting guide and specifications for servicing the engine body, lubrication system, cooling system, and fuel system.
This document provides information about an electrical circuit breaker project conducted by 4th year electrical engineering students at Benha University in Egypt. It lists the names and student numbers of 4 students involved in the project, with student numbers ranging from 73 to 138. The rest of the document discusses the basic working principles of electrical circuit breakers, including their components, operating mechanisms, types according to various classification schemes, and arc quenching technologies.
PERKINS 2200 SERIES 2206D-E13TA INDUSTRIAL ENGINE Service Repair Manualjsnekmse
This is the Highly Detailed factory service repair manual for thePERKINS 2200 SERIES 2206D-E13TA INDUSTRIAL ENGINE , this Service Manual has detailed illustrations as well as step by step instructions,It is 100 percents complete and intact. they are specifically written for the do-it-yourself-er as well as the experienced mechanic.PERKINS 2200 SERIES 2206D-E13TA INDUSTRIAL ENGINE Service Repair Workshop Manual provides step-by-step instructions based on the complete dis-assembly of the machine. It is this level of detail, along with hundreds of photos and illustrations, that guide the reader through each service and repair procedure. Complete download comes in pdf format which can work under all PC based windows operating system and Mac also, All pages are printable. Using this repair manual is an inexpensive way to keep your vehicle working properly.
Operation and Maintenance Manual Cover:
Safety Section
Product Information Section
Operation Section
Maintenance Section
Warranty Section
Index Section
Engine Schematic
Systems Operation Testing and Adjusting Cover:
Systems Operation Section
Testing and Adjusting Section
Fuel System
Air Inlet and Exhaust System
Lubrication System
Cooling System
Basic Engine
Electrical System
Index Section
Troubleshooting Manual Cover:
Introduction
Electronic System Overview
Configuration Parameters
Diagnostic Trouble Codes
Event Codes
Symptom Troubleshooting
Circuit Tests
Service
Index Section
File Format: PDF
Compatible: All Versions of Windows & Mac
Language: English
Requirements: Adobe PDF Reader
NO waiting, Buy from responsible seller and get INSTANT DOWNLOAD, Without wasting your hard-owned money on uncertainty or surprise! All pages are is great to havePERKINS 2200 SERIES 2206D-E13TA INDUSTRIAL ENGINE Service Repair Workshop Manual.
Looking for some other Service Repair Manual,please check:
https://www.aservicemanualpdf.com/
Thanks for visiting!
8
Identification and minimization of HarmonicsMayur Hiwale
In this ppt we will get to know about basic idea of harmonics, types of harmonics , measuring devices and minimizing techniques and also covering the there impact on power system and impact on consumer equipment's.
O manual fornece instruções para instalação, operação e manutenção de um compressor de parafuso. Ele inclui informações técnicas sobre o equipamento, procedimentos de segurança, operação, manutenção preventiva e solução de problemas. O manual também contém diagramas elétricos e de tubulação para referência.
O documento descreve as características principais dos televisores de plasma, incluindo:
1) Telas grandes e finas com ângulos de visão amplos;
2) Imagem uniforme sem influência de campo magnético;
3) Custo e consumo de energia maiores em comparação a outros tipos de televisores.
Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System
Surge arresters and surge suppressors are devices used to protect transformers and other electrical equipment from high voltage surges caused by lightning or switching. Surge arresters are used in high voltage systems to divert surges to ground, limiting the voltage. They contain metal oxide varistors that conduct current during surges but are otherwise insulators. Surge suppressors are similar devices used in low voltage electronics to short surges to ground. Both work to block unwanted voltages from damaging protected equipment like transformers.
This document provides specifications and operating instructions for the DSE60xx series control module. It includes information on part numbering, power supply requirements, inputs, outputs, dimensions, applicable standards, installation, operation, the module display, front panel configuration, commissioning, fault finding, and maintenance. The DSE60xx is a generator control and instrumentation system that can automatically start and stop the engine/generator. It monitors operational parameters and indicates fault conditions on its LCD display.
The document provides guidance on proper installation, maintenance, and operation of centrifugal pumps. It covers best practices for installation including having a sturdy foundation, properly leveling the baseplate, performing initial alignment of the pump and driver, and avoiding pipe strain on the pump. The document then discusses additional maintenance topics such as stuffing boxes, mechanical seals, bearings, vibration analysis, and record keeping.
This document provides instructions for operating a screw compressor controller:
1. It explains how to adjust important settings like display language and system pressure setpoint.
2. It describes how to log in using an equipment card for authentication and setting access levels.
3. The document outlines how to activate functions like the clock key and remote control key to schedule operations and control the compressor remotely.
Condition Monitoring of electrical machine Molla Morshad
Condition monitoring of electrical equipment is important to ensure reliability. Key stresses on equipment include thermal, electrical, ambient, and mechanical (TEAM) stresses. Condition is monitored by measuring operating stresses and comparing to design limits. Predictive maintenance is initiated if operating stresses exceed limits. Key parameters monitored include vibration, insulation properties, thermography, and oil analysis to detect issues like looseness, insulation degradation, overheating, and bearing wear. Regular monitoring and preventive maintenance helps maintain reliability by preventing failures during operation.
Este documento descreve um circuito transmissor de TV que pode transmitir sinais de vídeo e áudio de dispositivos como videocassetes para televisores nas proximidades. O circuito gera sinais modulados de vídeo e áudio usando osciladores controlados por transistores e bobinas cuidadosamente ajustadas para transmitir no canal 3. Instruções detalhadas são fornecidas para a montagem e ajuste do circuito.
O documento fornece instruções sobre a instalação, operação e manutenção de ventiladores centrífugos e axiais. Detalha os principais componentes destes ventiladores e seus tipos de construção, normas de projeto, segurança, manutenção preventiva, lubrificação e peças de reposição recomendadas.
This document provides specifications and installation instructions for the DSE4510 and DSE4520 generator control modules. It includes details on terminal descriptions, wiring diagrams, earth systems, display features, and installation requirements. The document covers topics such as voltage and current sensing requirements, input and output configurations, communication ports, dimensions and mounting instructions, and applicable safety and EMC standards.
Original N-CHANNEL MOSFET STF40NF20 40NF20 40N20 40A 200V TO-220 New STAUTHELECTRONIC
Original N-CHANNEL MOSFET STF40NF20 40NF20 40N20 40A 200V TO-220 New ST
https://authelectronic.com/original-n-channel-mosfet-stf40nf20-40nf20-40n20-40a-200v-to-220-new-st
That part of power system which distributes electric power for local use is known as DISTRIBUTION.
Electric power distribution is the final stage in the delivery of electricity. Electricity is carried from the transmission system to individual consumers. Distribution substations connect to the transmission system and lower the transmission voltage to medium voltage ranging between 2 kV and 33 kV with the use of transformers. Primary distribution lines carry this medium voltage power to distribution transformers located near the customer's premises. Distribution transformers again lower the voltage to the utilization voltage used by lighting, industrial equipment and household appliances. Often several customers are supplied from one transformer through secondary distribution lines. Commercial and residential customers are connected to the secondary distribution lines through service drops.
This document presents information about Buchholz relays. It discusses that Buchholz relays were first developed in 1921 and are installed in large power transformers to protect against internal faults. The relay contains an upper element that closes an alarm circuit during slow developing faults and a lower element that trips the circuit breaker during severe faults. It operates by detecting hydrogen gas generated from transformer oil decomposition during faults, with the gas causing floats that activate mercury switches to signal alarms or trip the transformer. Buchholz relays provide simple and effective protection for oil-immersed transformers while also detecting slow developing faults earlier than other methods.
This document discusses power transformer energy performance standards and regulations around the world. It covers background topics, common policy instruments used to promote energy efficiency, reference standards used to measure performance, and categories of energy performance metrics. Key points addressed include definitions of rated power, reference temperatures, frequencies and voltages in standards, as well as common metrics like maximum losses, minimum efficiency, and peak efficiency index.
Kioti daedong dk50 tractor service repair manualfjseedcxkmdmme
This document appears to be a chapter from a tractor repair manual. It provides general information about the tractor including views, specifications, identification numbers, and safety cautions for repair. It then details the engine components and systems, including the cylinder head, block, crankshaft, pistons, connecting rod, camshaft, fuel system, lubrication system, cooling system, intake and exhaust systems. It provides a troubleshooting guide and specifications for servicing the engine body, lubrication system, cooling system, and fuel system.
This document provides information about an electrical circuit breaker project conducted by 4th year electrical engineering students at Benha University in Egypt. It lists the names and student numbers of 4 students involved in the project, with student numbers ranging from 73 to 138. The rest of the document discusses the basic working principles of electrical circuit breakers, including their components, operating mechanisms, types according to various classification schemes, and arc quenching technologies.
PERKINS 2200 SERIES 2206D-E13TA INDUSTRIAL ENGINE Service Repair Manualjsnekmse
This is the Highly Detailed factory service repair manual for thePERKINS 2200 SERIES 2206D-E13TA INDUSTRIAL ENGINE , this Service Manual has detailed illustrations as well as step by step instructions,It is 100 percents complete and intact. they are specifically written for the do-it-yourself-er as well as the experienced mechanic.PERKINS 2200 SERIES 2206D-E13TA INDUSTRIAL ENGINE Service Repair Workshop Manual provides step-by-step instructions based on the complete dis-assembly of the machine. It is this level of detail, along with hundreds of photos and illustrations, that guide the reader through each service and repair procedure. Complete download comes in pdf format which can work under all PC based windows operating system and Mac also, All pages are printable. Using this repair manual is an inexpensive way to keep your vehicle working properly.
Operation and Maintenance Manual Cover:
Safety Section
Product Information Section
Operation Section
Maintenance Section
Warranty Section
Index Section
Engine Schematic
Systems Operation Testing and Adjusting Cover:
Systems Operation Section
Testing and Adjusting Section
Fuel System
Air Inlet and Exhaust System
Lubrication System
Cooling System
Basic Engine
Electrical System
Index Section
Troubleshooting Manual Cover:
Introduction
Electronic System Overview
Configuration Parameters
Diagnostic Trouble Codes
Event Codes
Symptom Troubleshooting
Circuit Tests
Service
Index Section
File Format: PDF
Compatible: All Versions of Windows & Mac
Language: English
Requirements: Adobe PDF Reader
NO waiting, Buy from responsible seller and get INSTANT DOWNLOAD, Without wasting your hard-owned money on uncertainty or surprise! All pages are is great to havePERKINS 2200 SERIES 2206D-E13TA INDUSTRIAL ENGINE Service Repair Workshop Manual.
Looking for some other Service Repair Manual,please check:
https://www.aservicemanualpdf.com/
Thanks for visiting!
8
Identification and minimization of HarmonicsMayur Hiwale
In this ppt we will get to know about basic idea of harmonics, types of harmonics , measuring devices and minimizing techniques and also covering the there impact on power system and impact on consumer equipment's.
O manual fornece instruções para instalação, operação e manutenção de um compressor de parafuso. Ele inclui informações técnicas sobre o equipamento, procedimentos de segurança, operação, manutenção preventiva e solução de problemas. O manual também contém diagramas elétricos e de tubulação para referência.
O documento descreve as características principais dos televisores de plasma, incluindo:
1) Telas grandes e finas com ângulos de visão amplos;
2) Imagem uniforme sem influência de campo magnético;
3) Custo e consumo de energia maiores em comparação a outros tipos de televisores.
Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System Staggering in Power System
Surge arresters and surge suppressors are devices used to protect transformers and other electrical equipment from high voltage surges caused by lightning or switching. Surge arresters are used in high voltage systems to divert surges to ground, limiting the voltage. They contain metal oxide varistors that conduct current during surges but are otherwise insulators. Surge suppressors are similar devices used in low voltage electronics to short surges to ground. Both work to block unwanted voltages from damaging protected equipment like transformers.
This document provides specifications and operating instructions for the DSE60xx series control module. It includes information on part numbering, power supply requirements, inputs, outputs, dimensions, applicable standards, installation, operation, the module display, front panel configuration, commissioning, fault finding, and maintenance. The DSE60xx is a generator control and instrumentation system that can automatically start and stop the engine/generator. It monitors operational parameters and indicates fault conditions on its LCD display.
The document provides guidance on proper installation, maintenance, and operation of centrifugal pumps. It covers best practices for installation including having a sturdy foundation, properly leveling the baseplate, performing initial alignment of the pump and driver, and avoiding pipe strain on the pump. The document then discusses additional maintenance topics such as stuffing boxes, mechanical seals, bearings, vibration analysis, and record keeping.
This document provides instructions for operating a screw compressor controller:
1. It explains how to adjust important settings like display language and system pressure setpoint.
2. It describes how to log in using an equipment card for authentication and setting access levels.
3. The document outlines how to activate functions like the clock key and remote control key to schedule operations and control the compressor remotely.
Condition Monitoring of electrical machine Molla Morshad
Condition monitoring of electrical equipment is important to ensure reliability. Key stresses on equipment include thermal, electrical, ambient, and mechanical (TEAM) stresses. Condition is monitored by measuring operating stresses and comparing to design limits. Predictive maintenance is initiated if operating stresses exceed limits. Key parameters monitored include vibration, insulation properties, thermography, and oil analysis to detect issues like looseness, insulation degradation, overheating, and bearing wear. Regular monitoring and preventive maintenance helps maintain reliability by preventing failures during operation.
Este documento descreve um circuito transmissor de TV que pode transmitir sinais de vídeo e áudio de dispositivos como videocassetes para televisores nas proximidades. O circuito gera sinais modulados de vídeo e áudio usando osciladores controlados por transistores e bobinas cuidadosamente ajustadas para transmitir no canal 3. Instruções detalhadas são fornecidas para a montagem e ajuste do circuito.
O documento fornece instruções sobre a instalação, operação e manutenção de ventiladores centrífugos e axiais. Detalha os principais componentes destes ventiladores e seus tipos de construção, normas de projeto, segurança, manutenção preventiva, lubrificação e peças de reposição recomendadas.
This document provides specifications and installation instructions for the DSE4510 and DSE4520 generator control modules. It includes details on terminal descriptions, wiring diagrams, earth systems, display features, and installation requirements. The document covers topics such as voltage and current sensing requirements, input and output configurations, communication ports, dimensions and mounting instructions, and applicable safety and EMC standards.
Original N-CHANNEL MOSFET STF40NF20 40NF20 40N20 40A 200V TO-220 New STAUTHELECTRONIC
Original N-CHANNEL MOSFET STF40NF20 40NF20 40N20 40A 200V TO-220 New ST
https://authelectronic.com/original-n-channel-mosfet-stf40nf20-40nf20-40n20-40a-200v-to-220-new-st
Original MOSFET N-Channel STGF10NC60KD GF10NC60KD 10NC60 10N60 10A 600V NewAUTHELECTRONIC
This document provides information on N-channel 600V-10A IGBTs from STMicroelectronics' PowerMESH product family. The IGBTs feature low saturation voltage, low CRES/CIES ratio to prevent cross-conduction, and a soft recovery diode. They are optimized for high frequency motor control applications and can withstand short circuits up to 10 microseconds. Electrical characteristics, switching performance curves, package details, and test circuits are included for the D2PAK, TO-220, and TO-220FP packaged devices.
Original N Channel Mosfet FQD10N60C STD10NM60N 10NM60 10N60 10A 600V TO-252 N...AUTHELECTRONIC
Original N Channel Mosfet FQD10N60C STD10NM60N 10NM60 10N60 10A 600V TO-252 New ST
https://authelectronic.com/original-n-channel-mosfet-fqd10n60c-std10nm60n-10nm60-10n60-10a-600v-to-252-new-st
Original MOSFET N-CHANNEL STF5NK52ZD 5NK52ZD 5NK52 5A 520V NewAUTHELECTRONIC
Original MOSFET N-CHANNEL STF5NK52ZD 5NK52ZD 5NK52 5A 520V New
https://authelectronic.com/original-mosfet-n-channel-stf5nk52zd-5nk52zd-5nk52-5a-520v-new
Original N-channel 650 V 0.230 Ohm 12 A MDmesh V Power MOSFET in DPAK DPAK ST...AUTHELECTRONIC
Original N-channel 650 V 0.230 Ohm 12 A MDmesh V Power MOSFET in DPAK DPAK STF16N65M5 16N65M5 16N65 710V 12A TO-220FP New STMicroelectronics
https://authelectronic.com/original-n-channel-650-v-0-230-ohm-12-a-mdmesh-v-power-mosfet-in-dpak-dpak-stf16n65m5-16n65m5-16n65-710v-12a-to-220fp-new-stmicroelectronics
Original IGBT STGF20H60DF GF20H60DF 20H60 600V 20A TO-220F New STMicroelectro...AUTHELECTRONIC
This document provides product information and specifications for 600 V, 20 A high speed trench gate IGBT devices. It includes details on the device features such as high speed switching, tight parameter distribution, safe paralleling capabilities, and low thermal resistance. Electrical ratings, characteristics and curves are provided covering parameters such as breakdown voltage, saturation voltage, switching times, losses and safe operating areas. The document is a datasheet for these IGBT devices in full production.
Original N-channel 600 V 0.160 Ω 19 A PowerFLAT™ 8x8 HV ultra low gate charge...AUTHELECTRONIC
This document provides information on the STL26NM60N N-channel 600 V, 0.160 Ω, 19 A PowerFLATTM 8x8 HV ultra low gate charge MDmeshTM II Power MOSFET, including:
- Key features such as being 100% avalanche tested and having low input capacitance and gate charge
- Applications in switching applications
- Description of the proprietary vertical and horizontal process technologies used to achieve extremely low on-resistance
- Electrical ratings, characteristics and switching performance curves
- Package mechanical data for the PowerFLATTM 8x8 HV package
Original N-Channel Mosfet STP65NF06 P65NF06 65A 60V TO-220 New STAUTHELECTRONIC
Original N-Channel Mosfet STP65NF06 P65NF06 65A 60V TO-220 New ST
https://authelectronic.com/original-n-channel-mosfet-stp65nf06-p65nf06-65a-60v-to-220-new
Original IGBT N-CHANNEL STGP7NC60HD GP7NC60HD 7NC60 14A 600V TO-220 Newauthelectroniccom
This document provides product information and specifications for N-channel 14 A, 600 V, very fast IGBT devices with an ultrafast diode (STGB7NC60HD, STGF7NC60HD, STGP7NC60HD) including:
- Key features such as low on-voltage drop, off losses including tail current, and high frequency operation up to 70 kHz.
- Applications including high frequency inverters, SMPS/PFC, and motor drivers.
- Package and ordering information for the IGBT devices in various packages including TO-220, TO-220FP, and D2PAK.
- Electrical ratings and characteristics including voltage, current, thermal data
Original N Channel Mosfet 110N8F6 STP110N8F6 110A 80V TO-220 NewAUTHELECTRONIC
This document provides product information for the STP110N8F6 power MOSFET, including:
1. Electrical ratings and characteristics such as maximum voltage, current, and on-resistance.
2. Test circuits for evaluating switching times and diode recovery.
3. Package information for the TO-220 package including mechanical dimensions.
Original Mosfet N 8N80C 8N80 FQPF8N80C FQPF8N80 8A 800V TO-220 New FairchildAUTHELECTRONIC
Original Mosfet N 8N80C 8N80 FQPF8N80C FQPF8N80 8A 800V TO-220 New Fairchild
https://authelectronic.com/original-mosfet-n-8n80c-8n80-fqpf8n80c-fqpf8n80-8a-800v-to-220-new
Original Mosfet N-channel IPAW60R600 60S600CE 600V 6A TO-220F NewAUTHELECTRONIC
This document provides specifications for the IPAW60R600CE 600V CoolMOSTM CE power transistor. Key details include:
- It is a 600V CoolMOSTM CE MOSFET designed for consumer and lighting applications using Infineon's superjunction technology.
- Features include low losses, high commutation ruggedness, ease of use, Pb-free and halogen-free packaging.
- It is specified for applications such as PFC stages, hard and resonant switching stages in devices like PC power supplies, adapters, LCD/PDP TVs, and indoor lighting.
- Electrical characteristics include a maximum drain-source voltage of 650V, on-resistance below 600
Similar to Original MOSFET P20NM60 20NM60 20N60C3 20N60 New (20)
Original Power Supply IC LNK632DG LNK632 632 SOP-7 NewAUTHELECTRONIC
The LNK632DG is an energy efficient constant voltage/constant current switcher for adapters and chargers. It dramatically simplifies CV converter designs by eliminating secondary control circuitry and compensation components. Some key features include auto-restart protection, hysteretic thermal shutdown, tight output regulation that compensates for cable voltage drops and temperature variations, and high efficiency down to light loads. It is well-suited for charger applications like cell phones, PDAs, and MP3 players.
The document summarizes an low-profile relay model called G5RL that is suitable for various applications. It has several models including standard, low noise, high inrush, and high capacity. Key specifications include a height of 15.7mm, 8mm creepage distance, 10kV impulse withstand voltage. It provides information on ordering, ratings for coils and contacts, characteristics, dimensions, and engineering data.
Original Transition-Mode PFC Controller IC LD7591GS 7591 SOP-8 New LeadtrendAUTHELECTRONIC
This document provides information about the LD7591 transition-mode PFC controller, including:
- It is a voltage mode PFC controller that operates in transition mode with protections like OVP, OCP, and brown-in protection.
- It has features like low startup current, over voltage protection, open feedback protection, disable function, and integrated current sensing.
- Typical applications include adapters over 65W, open frame switching power supplies, LCD TV power supplies, and LED power supplies.
Original NPN Darlington Transistor MC1413DR2G 1413DR2G NCV1413BDG 1413BDG 141...AUTHELECTRONIC
The document describes a high voltage, high current Darlington transistor array that is well-suited for driving lamps, relays, or printer hammers. It has 7 NPN Darlington connected transistors with a high breakdown voltage and internal suppression diodes to ensure safety with inductive loads. It can drive incandescent lamps with peak inrush currents up to 500mA per transistor.
Original EEPROM IC BR93L76RFJ 93L76 RL76 SOP-8 New RohmAUTHELECTRONIC
This document provides important safety information regarding the intended use of ROHM products. It states that the products are designed for ordinary electronic equipment but should not be used in applications requiring extremely high reliability where malfunctions could directly endanger human life, such as medical devices. It also notes the products are not designed with antiradiation properties and certain exports may require controls under Japanese law. Contact information is provided for sales representatives.
Original Advanced IGBT/Mosfet Driver TD350E 350E SOP-14 New ST MicroelectronicsAUTHELECTRONIC
This document provides information on an advanced IGBT/MOSFET gate driver called the TD350E, including its key features, applications, description, and specifications. The TD350E is designed for applications such as inverters, motor control, and UPS systems. It provides 1.5A/2.3A gate drive, active Miller clamping, two-level turn-off protection, desaturation detection, and fault status output. Electrical characteristics and timing diagrams are included to specify the device's performance.
Original N-Channel Mosfet 2SK3562 3562 TO-220 New ToshibaAUTHELECTRONIC
This document provides specifications and performance characteristics for the Toshiba 2SK3562 N-channel MOSFET transistor. Key details include:
- It is an enhancement mode transistor intended for switching regulator applications with low on-resistance of 0.9 ohms and forward transfer admittance of 5.0S.
- Maximum ratings include a drain-source voltage of 600V, drain current of 6A continuous or 24A pulse, and drain power dissipation of 40W.
- Electrical characteristics at 25C include a gate threshold voltage of 2.0-4.0V, on-resistance of 0.9-1.25 ohms, and input/output capacit
Original N-Channel Mosfet FDPF33N25 33N25 TO-220 New FairChildAUTHELECTRONIC
This document provides information on the FDPF33N25250VN-Channel MOSFET from Fairchild Semiconductor. It is a 250V N-Channel MOSFET with low on-resistance of 0.094Ω and fast switching capabilities. It uses Fairchild's proprietary planar stripe DMOS technology to minimize resistance and maximize performance for applications such as high efficiency power supplies. Key specifications and performance characteristics are provided.
Original N-Channel Mosfet IRFB4020PBF 4020 TO-220-3 New International RectifierAUTHELECTRONIC
This document provides specifications for a digital audio MOSFET designed for use in class D audio amplifier applications. The MOSFET has been optimized to achieve low on-resistance, gate charge, and reverse recovery charge for improved efficiency, total harmonic distortion, and electromagnetic interference. Additional features include a 175°C operating temperature and repetitive avalanche capability making it robust and reliable for audio amplifiers. Tables and graphs provide electrical characteristics and performance metrics.
Original Logic IC SN74LVC14A SN54LVC14A 74LVC14A 54LVC14A SOP-14 New Texas In...AUTHELECTRONIC
The document provides information on the SN54LVC14A and SN74LVC14A hex Schmitt-trigger inverter integrated circuits. It describes their operating voltage ranges from 1.65V to 3.6V, maximum propagation delay of 6.4ns at 3.3V, ESD protection exceeding 2000V human-body and 200V machine models, and thermal characteristics with package impedance ranging from 47°C/W to 127°C/W. Ordering information and packaging details are provided for various operating temperature ranges from -55°C to 125°C. Electrical characteristics like input thresholds, output voltages, input and output currents, and input capacitance are specified over operating conditions.
Original High Voltage Isolation IC ACS710T KLA-12CB 710T SOP-16 NewAUTHELECTRONIC
The Allegro ACS710 current sensor provides economical and precise current sensing for industrial, commercial, and communications systems. It uses a precision linear Hall sensor integrated circuit with a copper conduction path near the surface to linearly track the magnetic field generated by the applied current. The sensor offers high immunity to electrical noise and low offset drift, and provides an analog output voltage and integrated overcurrent detection. It is available in a small surface-mount package.
Original Voltage Regulator & Controller IC TPS54231DR 54231DR 54231 SOP-8 Ne...AUTHELECTRONIC
The document provides specifications and design information for the TPS54231 step-down DC-DC converter from Texas Instruments. The TPS54231 is a 2-A, 28-V input converter with an integrated high-side MOSFET. It features adjustable output voltage down to 0.8V, pulse skipping for high efficiency at light loads, fixed 570kHz switching frequency, and various protection mechanisms. Application areas include consumer, industrial, and automotive equipment requiring distributed power supplies. The device is available in an 8-pin SOIC package.
Original Microcontroller IC R5F104BDA R5F 104BDA 104 NewAUTHELECTRONIC
This document provides an overview and specifications for the Renesas RL78/G14 microcontroller, including:
- Ultra-low power consumption down to 66 μA/MHz and 0.60 μA for RTC + LVD. Operates from 1.6V to 5.5V.
- 16 to 512 KB flash memory, 44 DMIPS performance at 32MHz.
- Various low power modes like HALT, STOP, and SNOOZE.
- On-chip peripherals include timers, ADC, DAC, comparators, serial interfaces, and I/O ports.
- Packaged in LQFP, LSSOP, QFN packages with pin counts from 30
Original Power Factor Correction IC UCC28061DR 28061 SOP-16 New Texas Instrum...AUTHELECTRONIC
The UCC28061 is a transition-mode PFC controller that features natural interleaving to improve efficiency and reduce component size. It provides complete system-level protections including input brownout, output overvoltage, and thermal shutdown. The device utilizes a natural interleaving technique where both channels operate as masters synchronized to the same frequency, delivering strong matching and fast response.
Original Gate Driver IC TD62083APG 62083APG 62083 DIP-18 New ToshibaAUTHELECTRONIC
This document provides specifications for the TD62083APG/AFG and TD62084APG/AFG integrated circuits from Toshiba. They are 8-channel Darlington sink drivers comprised of NPN Darlington pairs, with each channel capable of 500mA of output current. Key features include integral clamp diodes, compatible inputs for various logic types, DIP-18 and SOP-18 packaging options. Electrical characteristics, test circuits, precautions and package dimensions are provided.
Original Zener Diode 1N5366B 5366B 5366 5W 39V NewAUTHELECTRONIC
This document provides information on ON Semiconductor's 1N53 Series 5 Watt Zener diodes. It includes specifications for over 40 Zener diode models with voltages ranging from 3.3V to 200V. The diodes feature tight voltage limits, low leakage current, and are packaged in axial lead plastic packages for protection in various environments. Maximum ratings and electrical characteristics like Zener voltage, impedance, and surge current are specified for each model in tables.
Original Audio Amplifier IC TDA7850 7850 SIP-25 New ST MicroelectronicsAUTHELECTRONIC
The document describes the TDA7850, a MOSFET audio power amplifier chip designed for high power car audio systems. It has a maximum output power of 4 x 50W into 4 ohms or 4 x 80W into 2 ohms. The chip features protections against overheating, short circuits, and other faults. It uses a fully complementary MOSFET output stage for rail-to-rail voltage swing and minimized distortion. Electrical specifications and application information are provided.
ACEP Magazine edition 4th launched on 05.06.2024Rahul
This document provides information about the third edition of the magazine "Sthapatya" published by the Association of Civil Engineers (Practicing) Aurangabad. It includes messages from current and past presidents of ACEP, memories and photos from past ACEP events, information on life time achievement awards given by ACEP, and a technical article on concrete maintenance, repairs and strengthening. The document highlights activities of ACEP and provides a technical educational article for members.
Comparative analysis between traditional aquaponics and reconstructed aquapon...bijceesjournal
The aquaponic system of planting is a method that does not require soil usage. It is a method that only needs water, fish, lava rocks (a substitute for soil), and plants. Aquaponic systems are sustainable and environmentally friendly. Its use not only helps to plant in small spaces but also helps reduce artificial chemical use and minimizes excess water use, as aquaponics consumes 90% less water than soil-based gardening. The study applied a descriptive and experimental design to assess and compare conventional and reconstructed aquaponic methods for reproducing tomatoes. The researchers created an observation checklist to determine the significant factors of the study. The study aims to determine the significant difference between traditional aquaponics and reconstructed aquaponics systems propagating tomatoes in terms of height, weight, girth, and number of fruits. The reconstructed aquaponics system’s higher growth yield results in a much more nourished crop than the traditional aquaponics system. It is superior in its number of fruits, height, weight, and girth measurement. Moreover, the reconstructed aquaponics system is proven to eliminate all the hindrances present in the traditional aquaponics system, which are overcrowding of fish, algae growth, pest problems, contaminated water, and dead fish.
Optimizing Gradle Builds - Gradle DPE Tour Berlin 2024Sinan KOZAK
Sinan from the Delivery Hero mobile infrastructure engineering team shares a deep dive into performance acceleration with Gradle build cache optimizations. Sinan shares their journey into solving complex build-cache problems that affect Gradle builds. By understanding the challenges and solutions found in our journey, we aim to demonstrate the possibilities for faster builds. The case study reveals how overlapping outputs and cache misconfigurations led to significant increases in build times, especially as the project scaled up with numerous modules using Paparazzi tests. The journey from diagnosing to defeating cache issues offers invaluable lessons on maintaining cache integrity without sacrificing functionality.
A review on techniques and modelling methodologies used for checking electrom...nooriasukmaningtyas
The proper function of the integrated circuit (IC) in an inhibiting electromagnetic environment has always been a serious concern throughout the decades of revolution in the world of electronics, from disjunct devices to today’s integrated circuit technology, where billions of transistors are combined on a single chip. The automotive industry and smart vehicles in particular, are confronting design issues such as being prone to electromagnetic interference (EMI). Electronic control devices calculate incorrect outputs because of EMI and sensors give misleading values which can prove fatal in case of automotives. In this paper, the authors have non exhaustively tried to review research work concerned with the investigation of EMI in ICs and prediction of this EMI using various modelling methodologies and measurement setups.
CHINA’S GEO-ECONOMIC OUTREACH IN CENTRAL ASIAN COUNTRIES AND FUTURE PROSPECTjpsjournal1
The rivalry between prominent international actors for dominance over Central Asia's hydrocarbon
reserves and the ancient silk trade route, along with China's diplomatic endeavours in the area, has been
referred to as the "New Great Game." This research centres on the power struggle, considering
geopolitical, geostrategic, and geoeconomic variables. Topics including trade, political hegemony, oil
politics, and conventional and nontraditional security are all explored and explained by the researcher.
Using Mackinder's Heartland, Spykman Rimland, and Hegemonic Stability theories, examines China's role
in Central Asia. This study adheres to the empirical epistemological method and has taken care of
objectivity. This study analyze primary and secondary research documents critically to elaborate role of
china’s geo economic outreach in central Asian countries and its future prospect. China is thriving in trade,
pipeline politics, and winning states, according to this study, thanks to important instruments like the
Shanghai Cooperation Organisation and the Belt and Road Economic Initiative. According to this study,
China is seeing significant success in commerce, pipeline politics, and gaining influence on other
governments. This success may be attributed to the effective utilisation of key tools such as the Shanghai
Cooperation Organisation and the Belt and Road Economic Initiative.
Presentation of IEEE Slovenia CIS (Computational Intelligence Society) Chapte...University of Maribor
Slides from talk presenting:
Aleš Zamuda: Presentation of IEEE Slovenia CIS (Computational Intelligence Society) Chapter and Networking.
Presentation at IcETRAN 2024 session:
"Inter-Society Networking Panel GRSS/MTT-S/CIS
Panel Session: Promoting Connection and Cooperation"
IEEE Slovenia GRSS
IEEE Serbia and Montenegro MTT-S
IEEE Slovenia CIS
11TH INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONIC AND COMPUTING ENGINEERING
3-6 June 2024, Niš, Serbia
Introduction- e - waste – definition - sources of e-waste– hazardous substances in e-waste - effects of e-waste on environment and human health- need for e-waste management– e-waste handling rules - waste minimization techniques for managing e-waste – recycling of e-waste - disposal treatment methods of e- waste – mechanism of extraction of precious metal from leaching solution-global Scenario of E-waste – E-waste in India- case studies.
3. STB20NM60/-1 - STP20NM60FP - STP20NM60 - STW20NM60 Electrical ratings
3/18
1 Electrical ratings
Table 2. Absolute maximum ratings
Symbol Parameter
Value
Unit
TO-220/D²PAK
I²PAK/TO-247
TO-220FP
VDS Drain-source voltage (VGS = 0) 600 V
VGS Gate- source voltage ±30 V
ID Drain current (continuous) at TC = 25°C 20 20 (1)
1. Limited only by maximum temperature allowed
A
ID Drain current (continuous) at TC = 100°C 12.6 12.6 (1)
A
IDM
(2)
2. Pulse width limited by safe operating area
Drain current (pulsed) 80 80 (1)
A
PTOT Total dissipation at TC = 25°C 192 45 W
Derating factor 1.5 0.36 W/°C
dv/dt (3)
3. ISD < 20A, di/dt < 400A/µs, VDD < V(BR)/DSS, Tj < TJMAX
Peak diode recovery voltage slope 15 V/ns
VISO
Insulation withstand voltage (RMS) from all
three leads to external heat sink
(t=1s;TC=25°C)
-- 2500 V
Tstg Storage temperature -65 to 150 °C
Tj Max. operating junction temperature 150 °C
Table 3. Thermal resistance
Symbol Parameter
TO-220/D²PAK
I²PAK/TO-247
TO-220FP Unit
Rthj-case Thermal resistance junction-case max 0.65 2.8 °C/W
Rthj-amb Thermal resistance junction-ambient max 62.5 °C/W
Tl
Maximum lead temperature for soldering
purpose
300 °C
Table 4. Avalanche data
Symbol Parameter Max. value Unit
IAS
Avalanche current, repetitive or not-
repetitive (pulse width limited by Tj max)
10 A
EAS
Single pulse avalanche energy
(starting Tj = 25 °C, ID = IAS, VDD = 50 V)
650 mJ
4. Electrical characteristics STB20NM60/-1 - STP20NM60FP - STP20NM60 - STW20NM60
4/18
2 Electrical characteristics
(TCASE=25°C unless otherwise specified)
Table 5. On/off states
Symbol Parameter Test conditions Min. Typ. Max. Unit
V(BR)DSS
Drain-source breakdown
voltage
ID = 250 µA, VGS = 0 600 V
IDSS
Zero gate voltage
drain current (VGS = 0)
VDS = Max rating
VDS= Max rating,@125°C
1
10
µA
µA
IGSS
Gate-body leakage
current (VDS = 0)
VGS = ± 30V ±100 nA
VGS(th) Gate threshold voltage VDS = VGS, ID = 250 µA 3 4 5 V
RDS(on)
Static drain-source on
resistance
VGS = 10V, ID = 10 A 0.25 0.29 Ω
Table 6. Dynamic
Symbol Parameter Test conditions Min. Typ. Max. Unit
gfs
(1)
1. Pulsed: Pulse duration = 300 µs, duty cycle 1.5 %
Forward transconductance
VDS > ID(on) x RDS(on)max,
ID = 10 A
11 S
Ciss
Coss
Crss
Input capacitance
Output capacitance
Reverse transfer
capacitance
VDS = 25V, f = 1 MHz,
VGS = 0
1500
350
35
pF
pF
pF
Coss eq.
(2)
2. Coss eq. is defined as a constant equivalent capacitance giving the same charging time as Coss when VDS
increases from 0 to 80% VDSS.
Equivalent output
capacitance
VGS = 0V, VDS = 0V to
480 V
215 pF
Qg
Qgs
Qgd
Total gate charge
Gate-source charge
Gate-drain charge
VDD = 480 V, ID = 20 A,
VGS = 10V
(see Figure 16)
39
10
20
54 nC
nC
nC
Rg Gate input resistance
f = 1 MHz Gate DC
bias=0 Test signal
level = 20 mV
open drain
1.6 Ω
5. STB20NM60/-1 - STP20NM60FP - STP20NM60 - STW20NM60 Electrical characteristics
5/18
Table 7. Switching times
Symbol Parameter Test conditions Min. Typ. Max. Unit
td(on)
tr
td(off)
tf
Turn-on delay time
Rise time
Turn-off delay time
Fall time
VDD = 300 V, ID = 10 A
RG = 4.7Ω VGS = 10 V
(see Figure 15)
25
20
42
11
ns
ns
ns
ns
Table 8. Source drain diode
Symbol Parameter Test conditions Min Typ. Max Unit
ISD
ISDM
(1)
1. Pulse width limited by safe operating area
Source-drain current
Source-drain current (pulsed)
20
80
A
A
VSD
(2)
2. Pulsed: Pulse duration = 300 µs, duty cycle 1.5 %
Forward on voltage ISD = 20 A, VGS = 0 1.5 V
trr
Qrr
IRRM
Reverse recovery time
Reverse recovery charge
Reverse recovery current
ISD =20A, di/dt=100A/µs,
VDD = 60 V
(see Figure 20)
390
5
25
ns
µC
A
trr
Qrr
IRRM
Reverse recovery time
Reverse recovery charge
Reverse recovery current
ISD =20A, di/dt=100A/µs,
Tj = 150°C, VDD = 60 V
(see Figure 20)
510
6.5
26
ns
µC
A
6. Electrical characteristics STB20NM60/-1 - STP20NM60FP - STP20NM60 - STW20NM60
6/18
2.1 Electrical characteristics (curves)
Figure 2. Safe operating area for TO-220 /
D²PAK / I²PAK
Figure 3. Thermal impedance for TO-220 /
D²PAK / I²PAK
Figure 4. Safe operating area for TO-220FP Figure 5. Thermal impedance for TO-220FP
Figure 6. Output characterisics Figure 7. Transfer characteristics
7. STB20NM60/-1 - STP20NM60FP - STP20NM60 - STW20NM60 Electrical characteristics
7/18
Figure 8. Transconductance Figure 9. Static drain-source on resistance
Figure 10. Gate charge vs gate-source voltage Figure 11. Capacitance variations
Figure 12. Normalized gate threshold voltage
vs temperature
Figure 13. Normalized on resistance vs
temperature
9. STB20NM60/-1 - STP20NM60FP - STP20NM60 - STW20NM60 Test circuit
9/18
3 Test circuit
Figure 15. Switching times test circuit for
resistive load
Figure 16. Gate charge test circuit
Figure 17. Test circuit for inductive load
switching and diode recovery times
Figure 18. Unclamped inductive load test
circuit
Figure 19. Unclamped inductive waveform Figure 20. Switching time waveform
10. Package mechanical data STB20NM60/-1 - STP20NM60FP - STP20NM60 - STW20NM60
10/18
4 Package mechanical data
In order to meet environmental requirements, ST offers these devices in ECOPACK®
packages. These packages have a Lead-free second level interconnect . The category of
second level interconnect is marked on the package and on the inner box label, in
compliance with JEDEC Standard JESD97. The maximum ratings related to soldering
conditions are also marked on the inner box label. ECOPACK is an ST trademark.
ECOPACK specifications are available at: www.st.com
11. STB20NM60/-1 - STP20NM60FP - STP20NM60 - STW20NM60 Package mechanical data
11/18
DIM.
mm. inch
MIN. TYP MAX. MIN. TYP. MAX.
A 4.85 5.15 0.19 0.20
A1 2.20 2.60 0.086 0.102
b 1.0 1.40 0.039 0.055
b1 2.0 2.40 0.079 0.094
b2 3.0 3.40 0.118 0.134
c 0.40 0.80 0.015 0.03
D 19.85 20.15 0.781 0.793
E 15.45 15.75 0.608 0.620
e 5.45 0.214
L 14.20 14.80 0.560 0.582
L1 3.70 4.30 0.14 0.17
L2 18.50 0.728
øP 3.55 3.65 0.140 0.143
øR 4.50 5.50 0.177 0.216
S 5.50 0.216
TO-247 MECHANICAL DATA
12. Package mechanical data STB20NM60/-1 - STP20NM60FP - STP20NM60 - STW20NM60
12/18
DIM.
mm. inch
MIN. TYP MAX. MIN. TYP. MAX.
A 4.40 4.60 0.173 0.181
b 0.61 0.88 0.024 0.034
b1 1.15 1.70 0.045 0.066
c 0.49 0.70 0.019 0.027
D 15.25 15.75 0.60 0.620
E 10 10.40 0.393 0.409
e 2.40 2.70 0.094 0.106
e1 4.95 5.15 0.194 0.202
F 1.23 1.32 0.048 0.052
H1 6.20 6.60 0.244 0.256
J1 2.40 2.72 0.094 0.107
L 13 14 0.511 0.551
L1 3.50 3.93 0.137 0.154
L20 16.40 0.645
L30 28.90 1.137
øP 3.75 3.85 0.147 0.151
Q 2.65 2.95 0.104 0.116
TO-220 MECHANICAL DATA
13. STB20NM60/-1 - STP20NM60FP - STP20NM60 - STW20NM60 Package mechanical data
13/18
DIM.
mm. inch
MIN. TYP MAX. MIN. TYP. MAX.
A 4.40 4.60 0.173 0.181
A1 2.40 2.72 0.094 0.107
b 0.61 0.88 0.024 0.034
b1 1.14 1.70 0.044 0.066
c 0.49 0.70 0.019 0.027
c2 1.23 1.32 0.048 0.052
D 8.95 9.35 0.352 0.368
e 2.40 2.70 0.094 0.106
e1 4.95 5.15 0.194 0.202
E 10 10.40 0.393 0.410
L 13 14 0.511 0.551
L1 3.50 3.93 0.137 0.154
L2 1.27 1.40 0.050 0.055
TO-262 (I2PAK) MECHANICAL DATA
14. Package mechanical data STB20NM60/-1 - STP20NM60FP - STP20NM60 - STW20NM60
14/18
L2
A
B
D
E
H
G
L6
F
L3
G1
1 2 3
F2
F1
L7
L4
L5
DIM.
mm. inch
MIN. TYP MAX. MIN. TYP. MAX.
A 4.4 4.6 0.173 0.181
B 2.5 2.7 0.098 0.106
D 2.5 2.75 0.098 0.108
E 0.45 0.7 0.017 0.027
F 0.75 1 0.030 0.039
F1 1.15 1.7 0.045 0.067
F2 1.15 1.7 0.045 0.067
G 4.95 5.2 0.195 0.204
G1 2.4 2.7 0.094 0.106
H 10 10.4 0.393 0.409
L2 16 0.630
L3 28.6 30.6 1.126 1.204
L4 9.8 10.6 .0385 0.417
L5 2.9 3.6 0.114 0.141
L6 15.9 16.4 0.626 0.645
L7 9 9.3 0.354 0.366
Ø 3 3.2 0.118 0.126
TO-220FP MECHANICAL DATA
15. STB20NM60/-1 - STP20NM60FP - STP20NM60 - STW20NM60 Package mechanical data
15/18
TO-247 MECHANICAL DATA
1
DIM.
mm. inch
MIN. TYP MAX. MIN. TYP. MAX.
A 4.4 4.6 0.173 0.181
A1 2.49 2.69 0.098 0.106
A2 0.03 0.23 0.001 0.009
B 0.7 0.93 0.027 0.036
B2 1.14 1.7 0.044 0.067
C 0.45 0.6 0.017 0.023
C2 1.23 1.36 0.048 0.053
D 8.95 9.35 0.352 0.368
D1 8 0.315
E 10 10.4 0.393
E1 8.5 0.334
G 4.88 5.28 0.192 0.208
L 15 15.85 0.590 0.625
L2 1.27 1.4 0.050 0.055
L3 1.4 1.75 0.055 0.068
M 2.4 3.2 0.094 0.126
R 0.4 0.015
V2 0º 4º
D2
PAK MECHANICAL DATA
3
16. Packaging mechanical data STB20NM60/-1 - STP20NM60FP - STP20NM60 - STW20NM60
16/18
5 Packaging mechanical data
TAPE AND REEL SHIPMENT
D2
PAK FOOTPRINT
* on sales type
DIM.
mm inch
MIN. MAX. MIN. MAX.
A 330 12.992
B 1.5 0.059
C 12.8 13.2 0.504 0.520
D 20.2 0795
G 24.4 26.4 0.960 1.039
N 100 3.937
T 30.4 1.197
BASE QTY BULK QTY
1000 1000
REEL MECHANICAL DATA
DIM.
mm inch
MIN. MAX. MIN. MAX.
A0 10.5 10.7 0.413 0.421
B0 15.7 15.9 0.618 0.626
D 1.5 1.6 0.059 0.063
D1 1.59 1.61 0.062 0.063
E 1.65 1.85 0.065 0.073
F 11.4 11.6 0.449 0.456
K0 4.8 5.0 0.189 0.197
P0 3.9 4.1 0.153 0.161
P1 11.9 12.1 0.468 0.476
P2 1.9 2.1 0.075 0.082
R 50 1.574
T 0.25 0.35 0.0098 0.0137
W 23.7 24.3 0.933 0.956
TAPE MECHANICAL DATA
17. STB20NM60/-1 - STP20NM60FP - STP20NM60 - STW20NM60 Revision history
17/18
6 Revision history
Table 9. Document revision history
Date Revision Changes
26-Jul-2004 8 First Release
17-Feb-2005 9 Insert the TO-247 package
25-Oct-2006 10 The document has been reformatted
18-Dec-2006 11 Text updates on Table 5.
27-Aug-2007 12 Updated Figure 2 and Figure 4