P r e s e n t a c i ó n 2 0 1 5
MPL – Global Leader in Data Centre Infrastructure
Management Technology
• MPL founded in 2004
• Operations in Spain established in 2007
• 5000+ devices installed in Spain since 2008
• Operations established in Brazil and Mexico in 2010
• 40,000+ devices installed Globally
• Largest installation with Santander: 9000 Devices + 2200 Racks
with Security Access Management
MPL Technology Group Expansion
Our business expansion has evolved around the ability to offer a vast
selection of products to complement the core Power Monitoring
solutions, with the aim of improving both the monitoring and control in
the management of the airflow:
– Wire Free Sensors
– Rack Access control
– Energy Efficiency Service - AIRLAB
– Air Flow Management Solutions
– Cold Aisle Containment
SPAIN
Global Clients and their Position
UK, SPAIN, GERMANY, USA, MEXICO &
BRAZIL
UK, EUROPE & MIDDLE EAST
SPAIN
GERMANY & HUNGARY
UK
Product Structure
Power Monitoring – Phase 1
The system allows for a connection of
up to 256 Devices over 1 x IP
The PDUs/In-liners can be Single or 3-
Phase
Option to connect a Temperature &
Humidity Sensors over RJ45 to the
hardware device
The Poller facilitates data to NGEN via
IP
Power Monitoring – Phase 2
Our In-Line range can support power
monitoring for Systems that are not
installed into a 19” IT Rack
The In-Line range can support power
requirements for 16a, 32a & 63a) in
single and 3-Phase
The system can connect up to 256
devices over 1 x IP
Each in-line monitor can also support 1
x T&H sensor which is connected via
an RJ45 patch lead
Wire-Free Sensors
Temperature & Humidity Wire-Free Sensors
MPL has introduced a Wire-Free range of products to meet a
constant challenge in managing the datacentre environment. With a
demand to increase CRAC set points globally and the rise in power
and cooling requirements, MPL have recognised the need to have a
flexible solution to manage both legacy and new Datacentre
infrastructure.
Complete Wire-Free Real-Time
Monitoring of your Datacentre
Wire Free T & H Monitoring
The wire free structure allows for the
installation of up to 63 sensors over 1 x
IP address. The quanitty of sensors is
made up of 3 x EDGE and 60 x RELAY
Sensors in a typical layout.
The relay sensors provide highly
accurate Temperature and Humidity
monitrong as well as delivering an
extensión to the overall range of
monitoring.
The Edge sensors provide highly
accurate monitoring of temperature and
humidity
Features and Benefits
Monitor all your critical areas; racks, cold aisles, hot aisles, CRAC supply and CRAC
returns. Mount and position to any rack in minutes and management with intuitive
easy to use software.
Each sensor forms part of a redundant
flexible Wire-Free mesh network
reporting data in real-time. Allowing
monitoring, alerting and granular
reports both for individual and group of
sensors utilising the NGEN Software
Framework.
Real-time and historical data analysis
Up-to 50 sensors per IP address
Utilise single battery and USB powered sensors
3 years lifespan on a single AA replaceable
battery
Full Datacentre range - daisy chaining the
sensor network
Automatic failover of sensors
Fit to any server rack
SNMP and Email alerts on threshold breaches
Multi Datacentre and Zone Segregation
Drag and Drop intuitive easy to use software
Dual USB powered and Battery options
Rack Access Control: Card Reader System
HID Card
Reader on
Mesh and
Glass/Perspex
Door
Rack Door Access Management
The Rack security management system
is controlled via a specific software
module in NGEN.
The hardware solution is made of a
RALF unit which links the card readers
for the fornt and rear door,
and manages the commands sent back
to the Poller unit over RS485
The system can support both HID and
MIFARE cards that are controlled via
the Sentry card reader which is
installed onto a rack or cold aisle door.
NGEN SOFTWARE & SYSTEM
TOPOLOGY
Network Concentrator
“POLLER”
IntelliPoller
Network
Aux PSU
Aux PSU
Aux PSU
Hasta 32 Racks por
cadena
Hasta 4 cadenas por
IntelliPoller
The Network Concentrator is an intelligent IP
interface for MPL’s power and environmental
monitoring and access control systems.
Key
Features
• MPL’s devices are connected via a RS485
serial data bus. The Concentrator controls 4
such busses allowing up to 256 monitoring
devices to be connected via a single IP
enabled connection point.
• If cabinet monitoring devices were to rely
solely on cabinet power to power their logic,
then they run the risk of not being able to
actively report a power failure when the
cabinet power fails. MPL’s monitoring
products are powered from the RS485 data
bus and the IntelliPoller supplies some or all
the power to the bus.
DCIM Software Platform
Real-Time Data Exchange
N-GEN achieves super efficient data exchange by only sending data as it changes
and only to users that have subscribed to see it.
• Low bandwidth consumption
• Low latency and no wait time
• Low memory consumption
• No long wait browser refreshes for data
• No delay or missed events
GEO Socket
Server
Mobile DevicesMutliple Desktop Users
N-GEN Database
PDU
Data
Only relevant real-time data is exchanged to each
user.
Simple Integration
Simple integration into other systems allows complete flexibility in meeting
your organisation's requirements.
N-GEN can send, receive and converge data easily using industry standard
methods.
Simple Integration
SNMP SOAP
SQL
Assets Capacity Server Requests 3rd
Party PDUs Tivoli
3rd Party PDUs
You can finally move away from clunky non-standard software and move to N-
GEN whilst retaining your existing PDU assets.
SNMP Based PDUs:
N-GEN can gather data from all SNMP based PDUs.
Bespoke PDUs:
The boom in socket monitored PDUs over the last 10 years without an industry
defined method of extracting the data has resulted in bespoke software and
PDUS from many manufacturers.
MPL have the ability to analyse bespoke PDUs and incorporate them into the N-
GEN real-time framework.
AFCO IDS Baytech ServerTech Sinetica
Power and Environmental Monitoring
NGEN provides the
capability to monitor at the
following levels: Outlet /
PDU / Rack / Row / Zone / IT
Room and Data centre.
NGEN also has the capbility
to interface with 3rd party
hardware to provide an option
for clients to centralize their
management tools into one
system should they have
different brands of product
from legacy environments.
Data Centre Layout and Information Tables
Power Distribution Mapping
Reporting Module
NGEN can deliver a range
of custom reports to suit
individual cleint
requirements. Examples
include:
- PUE
- PDUs on-line
- Power Circuit Availability
- Failure Reports
- Top 10 Racks with % KW usage
- Hotspot / Cold spot analysis
Software NGEN – Threshold Management
Threshold levels can be
configured to suit individal
device/rack requirements.
Alerts that are generated
from the devices can be sent
via Email or SNMP as
required. Las alertas también
pueden verse en una página
en N-GEN dedicada a este fin.
The Alerts can be set at the
following levels:
- Global
- Data centre
- Rack (Groups)
- Device – PDU / or sensor
– Integration with UNITE
NGEN has an integrated
SNMP module that
enables the system to
extract data from the
Unite IP based devices
MPL will request the MIB
File from the client in
order to understand the
data base layout for the
data readings that need
to be integrated
Once the field map is
created, the SNMP device
can then be added to
NGEN and the data can
be stored in the NGEN
data base
P r e s e n t a c i ó n 2 0 1 5

MPL 2016 PRESENTATION

  • 1.
    P r es e n t a c i ó n 2 0 1 5
  • 2.
    MPL – GlobalLeader in Data Centre Infrastructure Management Technology • MPL founded in 2004 • Operations in Spain established in 2007 • 5000+ devices installed in Spain since 2008 • Operations established in Brazil and Mexico in 2010 • 40,000+ devices installed Globally • Largest installation with Santander: 9000 Devices + 2200 Racks with Security Access Management
  • 3.
    MPL Technology GroupExpansion Our business expansion has evolved around the ability to offer a vast selection of products to complement the core Power Monitoring solutions, with the aim of improving both the monitoring and control in the management of the airflow: – Wire Free Sensors – Rack Access control – Energy Efficiency Service - AIRLAB – Air Flow Management Solutions – Cold Aisle Containment
  • 4.
    SPAIN Global Clients andtheir Position UK, SPAIN, GERMANY, USA, MEXICO & BRAZIL UK, EUROPE & MIDDLE EAST SPAIN GERMANY & HUNGARY UK
  • 5.
  • 6.
    Power Monitoring –Phase 1 The system allows for a connection of up to 256 Devices over 1 x IP The PDUs/In-liners can be Single or 3- Phase Option to connect a Temperature & Humidity Sensors over RJ45 to the hardware device The Poller facilitates data to NGEN via IP
  • 7.
    Power Monitoring –Phase 2 Our In-Line range can support power monitoring for Systems that are not installed into a 19” IT Rack The In-Line range can support power requirements for 16a, 32a & 63a) in single and 3-Phase The system can connect up to 256 devices over 1 x IP Each in-line monitor can also support 1 x T&H sensor which is connected via an RJ45 patch lead
  • 8.
  • 9.
    Temperature & HumidityWire-Free Sensors MPL has introduced a Wire-Free range of products to meet a constant challenge in managing the datacentre environment. With a demand to increase CRAC set points globally and the rise in power and cooling requirements, MPL have recognised the need to have a flexible solution to manage both legacy and new Datacentre infrastructure. Complete Wire-Free Real-Time Monitoring of your Datacentre
  • 10.
    Wire Free T& H Monitoring The wire free structure allows for the installation of up to 63 sensors over 1 x IP address. The quanitty of sensors is made up of 3 x EDGE and 60 x RELAY Sensors in a typical layout. The relay sensors provide highly accurate Temperature and Humidity monitrong as well as delivering an extensión to the overall range of monitoring. The Edge sensors provide highly accurate monitoring of temperature and humidity
  • 11.
    Features and Benefits Monitorall your critical areas; racks, cold aisles, hot aisles, CRAC supply and CRAC returns. Mount and position to any rack in minutes and management with intuitive easy to use software. Each sensor forms part of a redundant flexible Wire-Free mesh network reporting data in real-time. Allowing monitoring, alerting and granular reports both for individual and group of sensors utilising the NGEN Software Framework. Real-time and historical data analysis Up-to 50 sensors per IP address Utilise single battery and USB powered sensors 3 years lifespan on a single AA replaceable battery Full Datacentre range - daisy chaining the sensor network Automatic failover of sensors Fit to any server rack SNMP and Email alerts on threshold breaches Multi Datacentre and Zone Segregation Drag and Drop intuitive easy to use software Dual USB powered and Battery options
  • 12.
    Rack Access Control:Card Reader System HID Card Reader on Mesh and Glass/Perspex Door
  • 13.
    Rack Door AccessManagement The Rack security management system is controlled via a specific software module in NGEN. The hardware solution is made of a RALF unit which links the card readers for the fornt and rear door, and manages the commands sent back to the Poller unit over RS485 The system can support both HID and MIFARE cards that are controlled via the Sentry card reader which is installed onto a rack or cold aisle door.
  • 14.
    NGEN SOFTWARE &SYSTEM TOPOLOGY
  • 15.
    Network Concentrator “POLLER” IntelliPoller Network Aux PSU AuxPSU Aux PSU Hasta 32 Racks por cadena Hasta 4 cadenas por IntelliPoller The Network Concentrator is an intelligent IP interface for MPL’s power and environmental monitoring and access control systems. Key Features • MPL’s devices are connected via a RS485 serial data bus. The Concentrator controls 4 such busses allowing up to 256 monitoring devices to be connected via a single IP enabled connection point. • If cabinet monitoring devices were to rely solely on cabinet power to power their logic, then they run the risk of not being able to actively report a power failure when the cabinet power fails. MPL’s monitoring products are powered from the RS485 data bus and the IntelliPoller supplies some or all the power to the bus.
  • 16.
  • 17.
    Real-Time Data Exchange N-GENachieves super efficient data exchange by only sending data as it changes and only to users that have subscribed to see it. • Low bandwidth consumption • Low latency and no wait time • Low memory consumption • No long wait browser refreshes for data • No delay or missed events GEO Socket Server Mobile DevicesMutliple Desktop Users N-GEN Database PDU Data Only relevant real-time data is exchanged to each user.
  • 18.
    Simple Integration Simple integrationinto other systems allows complete flexibility in meeting your organisation's requirements. N-GEN can send, receive and converge data easily using industry standard methods. Simple Integration SNMP SOAP SQL Assets Capacity Server Requests 3rd Party PDUs Tivoli
  • 19.
    3rd Party PDUs Youcan finally move away from clunky non-standard software and move to N- GEN whilst retaining your existing PDU assets. SNMP Based PDUs: N-GEN can gather data from all SNMP based PDUs. Bespoke PDUs: The boom in socket monitored PDUs over the last 10 years without an industry defined method of extracting the data has resulted in bespoke software and PDUS from many manufacturers. MPL have the ability to analyse bespoke PDUs and incorporate them into the N- GEN real-time framework. AFCO IDS Baytech ServerTech Sinetica
  • 20.
    Power and EnvironmentalMonitoring NGEN provides the capability to monitor at the following levels: Outlet / PDU / Rack / Row / Zone / IT Room and Data centre. NGEN also has the capbility to interface with 3rd party hardware to provide an option for clients to centralize their management tools into one system should they have different brands of product from legacy environments.
  • 21.
    Data Centre Layoutand Information Tables
  • 22.
  • 23.
    Reporting Module NGEN candeliver a range of custom reports to suit individual cleint requirements. Examples include: - PUE - PDUs on-line - Power Circuit Availability - Failure Reports - Top 10 Racks with % KW usage - Hotspot / Cold spot analysis
  • 24.
    Software NGEN –Threshold Management Threshold levels can be configured to suit individal device/rack requirements. Alerts that are generated from the devices can be sent via Email or SNMP as required. Las alertas también pueden verse en una página en N-GEN dedicada a este fin. The Alerts can be set at the following levels: - Global - Data centre - Rack (Groups) - Device – PDU / or sensor
  • 25.
    – Integration withUNITE NGEN has an integrated SNMP module that enables the system to extract data from the Unite IP based devices MPL will request the MIB File from the client in order to understand the data base layout for the data readings that need to be integrated Once the field map is created, the SNMP device can then be added to NGEN and the data can be stored in the NGEN data base
  • 26.