V1/1
V1/2
V1/3
V1/4
V1/5
V1/6
V1/7
900600 7725
2738
427
2396
200
15.0
TANK
RL
R
L
R
L
CL CL CL
W
D
W
D
WD
W
D
WD
WL
WL
W
L
W
L
WL
T1 19 OFF - 51 kg/ply
600600 7700
1458
427
427
200
200
15.0
TANK
RL
R
L
RL
CL CL CL CL
WD
WDWL
WL WL
WL
T2 9 OFF - 47 kg/ply
1100600 7200
1458
427
561
200
200
15.0
TANK
RL
R
L
RL
CL CL CL CL
WD
WD
WL WL
T3 4 OFF - 44 kg/ply
RL
RL
RL
RD
RD
WD WD WD WD WDWD WD WD WD
WL
WL
WD WD
WL
WL
WD WD
WL
RL RL
RD
RL
RD
WL WL
WD WL WLWD
RD RLRDWD WLWD
RL
RLRL
THIS INFORMATION IS SUPPLIED IN GOOD
FAITH BUT WITHOUT LIABILITY. IT IS THE
BUILDING DESIGNERS RESPONSIBILITY TO
ENSURE THE STABILITY OF THE OVERALL
STRUCTURE.
Ceiling Tie Level
Rafter Level
Section A-A
Section B-B
B B
A
A
TRUSS LEGEND
19No. T1 7725 15.0, 9No. T2 7700 15.0
4No. T3 7200 15.0
WOLF SYSTEMS LTD
WolfPlan 5.44
DRG NO : 15/10065/15 10065-2
PROJECT : Kilcaven Property Developments LtdDATE : 26-1-2016SPACING :600mm
LOADS:Tiles=685 Snow=600 N/m2
SITE :Kilmuckridge National School Kilmuckridge
Dempsey Timber Engineering, Dublin Rd., Arklow, Co. Wicklow. Ph. 0402-31704
Checked :Drawn : Patrick Higgins
7200
8325
11025
8300600 2125
72008325
300 7725 300600
2738
300 7700 300
300
300
1458
T1
T2
T3
CL
CL
CL
CD
CD
CD
CD
CL CL CL
CL
CL
MJHMJHMJHMJHMJHMJHMJHMJHMJHMJHMJHMJHMJHMJHMJHMJHMJHMJH MJH

Layout for Approval-17

  • 1.
    V1/1 V1/2 V1/3 V1/4 V1/5 V1/6 V1/7 900600 7725 2738 427 2396 200 15.0 TANK RL R L R L CL CLCL W D W D WD W D WD WL WL W L W L WL T1 19 OFF - 51 kg/ply 600600 7700 1458 427 427 200 200 15.0 TANK RL R L RL CL CL CL CL WD WDWL WL WL WL T2 9 OFF - 47 kg/ply 1100600 7200 1458 427 561 200 200 15.0 TANK RL R L RL CL CL CL CL WD WD WL WL T3 4 OFF - 44 kg/ply RL RL RL RD RD WD WD WD WD WDWD WD WD WD WL WL WD WD WL WL WD WD WL RL RL RD RL RD WL WL WD WL WLWD RD RLRDWD WLWD RL RLRL THIS INFORMATION IS SUPPLIED IN GOOD FAITH BUT WITHOUT LIABILITY. IT IS THE BUILDING DESIGNERS RESPONSIBILITY TO ENSURE THE STABILITY OF THE OVERALL STRUCTURE. Ceiling Tie Level Rafter Level Section A-A Section B-B B B A A TRUSS LEGEND 19No. T1 7725 15.0, 9No. T2 7700 15.0 4No. T3 7200 15.0 WOLF SYSTEMS LTD WolfPlan 5.44 DRG NO : 15/10065/15 10065-2 PROJECT : Kilcaven Property Developments LtdDATE : 26-1-2016SPACING :600mm LOADS:Tiles=685 Snow=600 N/m2 SITE :Kilmuckridge National School Kilmuckridge Dempsey Timber Engineering, Dublin Rd., Arklow, Co. Wicklow. Ph. 0402-31704 Checked :Drawn : Patrick Higgins 7200 8325 11025 8300600 2125 72008325 300 7725 300600 2738 300 7700 300 300 300 1458 T1 T2 T3 CL CL CL CD CD CD CD CL CL CL CL CL MJHMJHMJHMJHMJHMJHMJHMJHMJHMJHMJHMJHMJHMJHMJHMJHMJHMJH MJH