More Related Content
Similar to Roof Truss Design and Specification for Dundrum Dublin Project
Similar to Roof Truss Design and Specification for Dundrum Dublin Project (20)
More from Patrick Higgins
More from Patrick Higgins (20)
Roof Truss Design and Specification for Dundrum Dublin Project
- 1. 2256140225
450450 6590
2697
38.0
TANK
T1 17 OFF - 40 kg/ply
2256160225
450450 6610
2705
38.0
T2 2x2PLY - 40 kg/ply
THIS INFORMATION IS SUPPLIED IN GOOD
FAITH BUT WITHOUT LIABILITY. IT IS THE
BUILDING DESIGNERS RESPONSIBILITY TO
ENSURE THE STABILITY OF THE OVERALL
STRUCTURE.
TC38 34 OFF 38mm Truss Clip. (TC38)
T1x34
FAS 22 OFF Framing Anchor. (FAS)
T2x8
TM38 9 OFF 38mm Midi Shoe. (TM38)
PFS 16 OFF 30x5x1600 150mm bend Restraint Strap. (PFS1500/100)
VRS 14 OFF 30x2.5x1000 100mm bend Restraint Strap. (VRS900/100)
Group No1
Jack Rafters : 35x 97 T26
Purlins : 35x 97 T26
Ceiling Joists : 35x 97 T26
Binders : 35x 97 T26
TRUSS LEGEND
17No. T1 6610 38.0, 2No. T2 6610 38.0
Section A-A
Rafter Level
Ceiling Tie Level
WOLF SYSTEMS LTD
WolfPlan 5.45
DRG NO : 15 09012 site REV2
PROJECT : Mark LynchDATE : 9-3-2016SPACING :600mm
LOADS:Tiles=685 Snow=600 N/m2
SITE :Dundrum Dublin
Dempsey Timber Engineering, Dublin Rd., Arklow, Co. Wicklow. Ph. 0402-31704
Checked :Drawn : Patrick Higgins
107656160
10765
6160
10565
5940
5940 325
449
280
2697
T1T1 T2
TM38TM38 TM38
TM38 TM38
TM38 TM38
TM38 TM38
Bracing Colours
Rafter Diagonal (RD) _________
Rafter Longitudinal (RL) _________
C/Tie Diagonal (CD) _________