@ http://www.vedard.com You can find the professional security systems supplier from China manufacturer. Retail & wholesale home security systems, and home security store online for easy purchase from China producer. Buy home security systems, alarm systems from China with low price and detailed installation
9. LCD display
Set Mon Tues Wed Thur Fri Sat Sun Disarm
Phone Home Arm
Date
Timer
Away Arm Horn
Zone 1 2 3 4 5 6 7 8 Report
Attribute 9 10 11 12 13 14 15 16 Enroll
DC
Pin Burglary Perimeter Duress Panic Fire Gas Medical Siren
Delay Line-Cut Fault AC DC L-Power GSM Rec/Play Arm
Alarm
Indicator
Network Intelligent Alarm System
Dial
GSM
Set
Function key
Query OK
Reset
Number key
MIC
Picture 1 Sketch diagram of panel
Set Mon Tues Wed Thur Fri Sat Sun Disarm
Phone Home Arm
Date Away Arm
Timer
Zone 1 2 3 4 5 6 7 8 Report
Attribute 9 10 11 12 13 14 15 16 Enroll
Pin Burglary Perimeter Duress Panic Fire Gas Medical Siren
Delay Line-Cut Fault AC DC L-Power GSM Rec/Play
Picture 2 LCD View
Wed.
month day hour minute
Status
Away Arm
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
(Picture 3) Sketch diagram in standby
.3 .
10. “GSM” Indicator: This function is for option. When GSM module was
chosen, the indicator will indicate the situation of the wireless signal
of GSM module as follows:
A) ON: normal signal
B) Flashing: weak signal
C) OFF: too weak signal or of no signal. It will affect the
communication of GSM. Moreover, if “GSM” indicator is still OFF
after power it on 3 minutes, it is necessary to check the installation
of SIM card.
.4 .
11. KS-110B
Wireless PIR
1
4
2
5
3
6
A
C
B
D
Detector
7 8 9 E F
1 2 3 4 5 6
7 8
0 #
*
CID Wireless Door
Sensor
Remote Set
Alarm process Telephone
Telephone Alarm Spot Monitor Wireless Smoke
Remote Set 1
9
2
10
3
11
4
12
5
13
6
14
7
15
8
16
Sensor
Alarm process
Mobile
Wireless Gas
Sensor
Emergency
On-site
Wireless Siren Emergency Button
Alarm Alarm Unit
Emergency
Arm/ Disarm Remote Controller
Wired Siren
Network Intelligent Alarm System (433.92MHz)
KS-110B
Wireless PIR
1
4
2
5
3
6
A
C
B
D
Detector
7 8 9 E F
1 2 3 4 5 6
7 8
0 #
*
CID Wireless
Door Sensor
Remote Set
Alarm process Telephone
Telephone Alarm Spot Wireless
Monitor
Remote Set
1
9
2
10
3
11
4
12
5
13
6
14
7
15
8
16
Smoke Sensor
Repeater
Alarm process
Mobile
Wireless
Gas Sensor
Emergency
On-site
Alarm Emergency Button
Wired Siren
Alarm Unit
Emergency
Arm/ Disarm Remote Controller
Network Intelligent Alarm System (315.65MHz)
.5 .
12. panel
Battery
case
1
Picture 4
Wiring slot Tamper Wiring terminal
Switch
1 1
Picture a Picture b
.5 .
13. upper mounting hole
79.9mm
under mounting hole
152mm
Picture 5
5.5mm
Note: Three screws
installed are away
from wall 5.5mm as
picture showing
Picture 6 Picture 7
(Volume: L→H)
LINE PHONE
( line inspect switch)
( OFF for close inspection)
OFF K1 ON
(ON for start inspection)
LINE
Picture 8
(Telephone connection)
.6 .
14. Wired detectors installation
Z16 GND Z15 Z14 GND Z13 AUX GND Detector 1 Detector 2 Detector 3
GND
The connection way of multiple NC detectors
Detector 1 Detector 2 Detector 3
GND
The connection way of multiple NO detectors
Detector 1
Detector 2 Detector 3
GND
(PIR detector (NC) Emergency button (NO) The integrated connection way of NO/ NC detectors
.7 .
15. NO COM NC GND AUX NO COM NC GND AUX
Wire anode
Black for cathode
Black for cathode
cathode Adapter
Red for anode
Red for anode
DC 12V wired siren DC 12V wired siren
(max current 150mA) (max current 150mA)
.8 .
16. ~d i ~ 1 Away Arm
2 Home Arm
4 Disarm
Picture 9
.9 .
17. The detector sends Make alarm and dial the set After receiving the alarm, you
the alarm signal to telephones after receiving can operate the alarm system
the alarm system. the alarm signal. on the key of telephone as follows:
[0][#] Exit [1][#] Away Arm
[2][#] Eliminate Alarm & Disarm [ 3][#] Spot siren on/off
[4][#] Monitor the spot [5][#] Repeat the record
Picture 10
.10 .
18. Telephone Telephone Telephone Mobile
The first Tel The second Tel The forth Tel The eighth Tel
2. After receiving alarm, the alarm system will dial
the set telephones in order. If the Alarm on-site is Wireless PIR
Detector
set, the alarm system will make alarm on-site at the
PSTN
same time.
e
sit
Wireless Door
Sensor
n-
ro
ito
on
M
Wireless Smoke
Sensor
Send alarm signal to
Alarm software 1. The detector
triggered and send
Wireless Gas
signal to alarm panel Sensor
KS-110B
1 2 3 A B
4 5 6 C D
7 8 9 E F
1 2 3 4 5 6
7 8
0 #
*
Alarm E Arm Emergency
center
3. Send the KS-899 433MHz m /
e Di Button
alarm information rg sa
to alarm center e rm
n
cy
alarm center
Wed
Remote
Controller
LCD Screen
1
Perimeter
4. When receiving the alarm signal, the alarm system will display the information
on LCD screen, which including alarm time, zone and type, etc.
Picture 9
.11 .
19. di
X X X X X X #
Call the phone number Wait for the right times arrives, Input the user's code and
that alarm panel connected you will hear a DI, operate it as follows
[0][#] Exit [ 1][#] Away Arm
[2][#] Eliminate alarm & Disarm [3 ][#] activate/disactivate spot siren
[4 ][#] monitor spot [ 5][#] Repeat the record
Picture 12
Wed
1
Perimeter
.12 .
30. 1 The 1st phone number
2 The 2nd phone number
Phone 3 The 3rd phone number
………………………
………………………
8 The 8th phone number
Clock
1 Arm for first Timer
Timer 2 Disarm for first Timer
3 Arm for Second Timer
4 Disarm for Second Timer
1 Away Arm Zones List
Zone
2 Home Arm Zones List
Burglar
1 01 zone attribute Perimeter
2 02 zone attribute Duress
Set 3 03 zone attribute Panic
Attribute ………………………
Fire
………………………
Gas
16 16 zone attribute
Medical
Pin
1 Alarm Delay
2 Arm Delay
Delay 3 Siren Duration
4 Ringing Times
5 Dialing Times
6. CID Timer Communication
1 Report of CID alarm center
Report
2 Report of Relay
1 1st zone
2 2nd zone
3 3rd zone
“1” for Detectors
………………………
………………………
16 16th zone
Enroll 1 1st remote controller
2 2nd remote controller
“2” for Remote 3 3rd remote controller
controller
……………………
……………………
8 8th remote controller
1 Siren ON/ OFF
Siren
2 siren address code
Record/ 1 Playback
Playback 2 Record
.23 .
33. Chart of parts
working mode
1. Power saving mode,
2. Standard Mode,
S 3. Test mode
M Tamper switch
L
Detective distance
ON/OFF
Planform
Working mode
110°
Infrared sensor
Indicator 12V DC input
Light on
Light off
12 10 8 4 2 0 2 4 8 10
NOTE:
side view
Power saving mode: If the people enter the detective area and keep
2.2m moving continuously. The infrared detector sends one signal at first
trigger only. The infrared detector won't send new signal while
trigger after 10 seconds immovability.
Standard mode: The Infrared detector sends the signal every 10
seconds.
Test mode: It is used to detect the infrared detective range only. As
long as the human body moves in the detective range, the indicator
2 4 6 8 10 will light on. It doesn't send the signal out.
.26 .
34. distance
Detective
Temperature-compensating at stated time
8m
6m
Traditional temperature-compensating
0 27 30 40 temperature( )
The wireless PIR detector can detect the changeful temperature in full-
procedure and take on temperature-compensating at stated time
automatically. It avoid the defective of traditional compensate, also
help to abstain the influence caused by “close-body temperature's
effect”.
Installation & Usage
Fix the universal block on the
Assemble the universal wall by screw. It is suggested
block with the universal to be installed above
ball. approximately 2.2m.
2.2M
1 2
Avoid the places strong-
interference, such as
Hitch the detector. conditioner, fanner,
refrigerator, oven,
windows and so on.
3 4
Hidden areas formed by barriers
Barriers, such
as bookshelves
Abstain from any objects The antenna should be upturned
lying in the front of the to insure the detective function
detector's lens. and wireless eradiated effect.
5 6
.27 .
35. Usage
After the detector was mounted on the wall, turn the PIR switch to “ON”.
The indicator light flashes once every second. The detector enters in
blank situation. The indicator light stops flashing in 60 seconds, then the
detector works normally. The user can walk across the detective areas
temporality to observe whether LED lights on or not. Meanwhile, the
detector will eradiate wireless alarm signal to alarm system. The user
can adjust the installation angle to reach the best detective effect as
their requirement. When LED is ON, it means LED indicator is on. The
function of jumper for LED ON is just to control the LED indicator's
indication function. It will not affect the normal work situation.
NOTES:
1. Please install and use the detector as the manual's requirement.
Don't touch the exterior of sensor lest affect the sensitivity of detector. If
it need to be cleaned, please use the soft cloth wetting with alcohol to
wipe it off after turning power off.
2. Avoid the changeful environment.
3. This detector can reduce the occurrence of incidents, but without
design to foolproof all time. Besides using our products correctly as the
manual's description, please make sure you are trying to improve the
consciousness to keep away yourself from the unsafe incidents.
.28 .
36. 1. Instruction
Wireless door sensor matches with a magnet. It sends alarm signal to alarm
console when both parts seperated. The door sensor is designed in micro
power consumption with low power alert. The wireless transmitter adopts
SAWF. It is more stable. The transmitting
distance in open area can reach to 250m or more.
Magnet Door sensor
2. Installation
Remove the paper on double-faced glue on both door sensor and magnet.
Glue sensor and magnet in proper place you want. Be sure the antenna of
door sensor to be in uprightness (up or down).
3. Note
1. The magnet part is asked to be installed in mobile door or window. For
example, install magnet art on mobile place. And install sensor part on fixed
place.
2.The distance of both magnet part and sensor part is not beyond 10MM.
3. Please pull out the antenna to be sure the wireless transceiver effect.
4. Please replace the battery once you find out the Alarm/Low Power
Indicator is in red.
.29 .
37. 4. Component Diagram
1 2 3 4
1. Transmitting Code Jumper : To change wireless code with jumper
place.
2. Magnet: To match with sensor to perform alarm.
3. Low Power Indicator: Red indicator for power lower.
4. Alarm Indicator: Red indicator for alarm,
.30 .