Jason Miller is seeking a leadership role in industrial automation technology. He has 14 years of experience in industrial automation, controls, and remote monitoring. Most recently, he worked as an Engineering and SCADA Administrator for Marathon Oil, where he developed and maintained a SCADA network covering over 500 oil wells. Prior to that, he worked as Gas Plant Manager and Computer and IT Consultant. He has skills in SCADA design, automation control, networking, and troubleshooting.
An overview of the specialised work carried out by Premium Power, an electrical engineering consultancy in areas such as electrical safety, risk assessment, arc flash, analytical studies, renewables and grid compliance, power quality and harmonics and hardware design, supply and commissioning.
An overview of the specialised work carried out by Premium Power, an electrical engineering consultancy in areas such as electrical safety, risk assessment, arc flash, analytical studies, renewables and grid compliance, power quality and harmonics and hardware design, supply and commissioning.
1. Jason Miller
SCADA Developer
2343 5th Street West
Dickinson, ND 58601
Phone: (701) 590-5967
Email: jasongtm@gmail.com
Career Objective
I am looking for a challenging leadership role in applied industrial automation technology with a
progressive, growth oriented company. I enjoy a safety orientated team based environment and my
14 years of progressive professional work experience in industrial automation, controls, and remote
monitoring, make me an ideal candidate in any automation team.
Work Experience
Engineering and SCADA Administrator
Marathon Oil Company - Dickinson, ND October 2011 to Present
Responsibilities
Develop and maintain a Wonderware/ArchestrA SCADA network covering over 500 high producing oil
wells in the Bakken Asset. I routinely work with P&ID’s, Cause & Effect, and Plot Plans in order to
produce wellsite automation and remote monitoring schemes. Taking the layouts from the Facilities
Engineering group, I produce the field automation architectures and configuration programming.
- Create and maintain I/O and Register maps for Top Server and AutoSol Enterprise Server.
- Develop new custom object and graphics utilizing script and I/O sourcing in ArchestrA
- Deploy, maintain and troubleshoot our Ethernet data radio network.
RTU/PLC program design and implementation.
- Design and configure programs for Emerson ROC and ABB XRC remote terminal units.
- Setup Modbus communication using serial and Modbus/TCP
- Provide support for company instrumentation and electrical staff members
Accomplishments
- Implementation of fiber optic I/O for field level devices using analog, digital and modbus
communications.
- Research and test new technologies
Skills Used
- SCADA design and development
- Automation control and design
- Networking
- Troubleshooting
- CFOT Certified Fiber Optics Tech
Gas Plant Manager
Kentucky Blue Gas Company 2007 to October 2011
Bowling Green, KY 42101
Working as plant manager, I supervised a small group of 9 professionals responsible for operating,
optimizing and maintaining all plant instrumentation, gas analysis, gas measurement, plant
operations, and field instrumentation.
- As Plant Manager we maintained a superior safety record, while ensuring maximum plant
utilization and quality control.
2. - I served as Project Manager on a plant expansion project wherein we expanded plant throughput
by 48%. As project manager I oversaw the general design, construction, commissioning, and plant
startup.
- Installed and configured a Wonderware SCADA system, automated valves, pressure and
temperature transmitters, flow meters, RTU units and chromatographs.
- Managed company safety program and implement safety policies.
Computer and IT Consultant
Thasay/MiTech Computers 2000 to 2008
Consultant, Owner and President of a small personal computer building, deployment and service
company. Serving small and medium sized companies across the two state area, I developed a strong
customer base.
- Custom built and repaired client personal computers.
- Setup networks, VPN's, IP Cameras with remote DVR access.
- Setup VOIP phone systems.
- Provided online and telephone support as well as onsite services.
Turbine Engine Specialist
United State Army Veteran – Honorable Discharge 1996 to 2004
As a turbine engine specialist, I was responsible for maintenance, troubleshooting and repairs on the
Abrams M1A1, M1A2 tank. I was responsible for troubleshooting and servicing over $400MM in
equipment with no losses. My main duties were to perform preventative maintenance and repairs on
the turbine, powertrain, nuclear biological chemical system(NBC), halon and controls system.
- Completed and graduated the U.S. Army Leadership training program
Skills
ArchestrA, Wonderware, InTouch, Programming, Modbus, Communications, Automation Controls
and Design,
Education
Graduated from Warren East High School in 1996
Completed University course work at Western Kentucky University in 2000
Additional Information
- Operating Systems: Proficient in all Windows based systems from MS Windows 95 through MS
Windows 8.
- Networking: Radio backbone network, VPN, Security cameras both remote and local, DVR,
Wireless and Cat5e integrated systems.
- Hardware: ABB Total Flow, Daniels, SRI, Dresser, Flow Serve, Fisher, RedLion, ROC800 Series,
Micrologix, VFD's
- Programs: Wonderware, ArchestrA, AutoSol, TopServer, Historian, PCCU, ROC Link, Crimson,
RSLogix, Factory Talk, Mon 2000
- Miscellaneous: Gas analysis, GC Programming, CFOT
- Safety: First Aid and Blood Bourn Pathogen Certified. CPR and AED Certified.