1) The author was asked to investigate screw design problems at a sheet extrusion facility with issues on all 5 of its lines.
2) To begin, the author measured the thermal expansion of one extruder barrel according to theoretical calculations and found it was within 0.030 inches, showing around 0.750 inches of expansion as expected. Wear patterns on screw flights were also consistent.
3) Process data gathered revealed the screw speed readings were miscalibrated, with one reading 24% too low and another 23% too high compared to actual counts, indicating the importance of verifying instrument readings.