A presentation about wastewater improvement projects using membrane systems. Presented by Joe Longo and Tom Lee from Horsley Witten Group during the Buzzards Bay Coalition's 2011 Decision Makers Workshop series. Learn more at www.savebuzzardsbay.org/DecisionMakers
3. MCI Plymouth
• Existing Title 5 System
– Serving 200 Inmates, 15 staff = 13,825 GPD
– Failed Inspection in Sept 2007
• Need - Expanding Population
– Design System to Serve 300 inmates, 21 staff for
31,000 GPD (**100 GPD/Inmate**)
• Reason for MBR - Campus is located
within several Drinking Water Zone IIs
– Effluent Quality to Meet DEP’s Interim
Guidelines on Reclaimed Water
Horsley Witten Group, Inc.
4. Permits
(Plymouth)
• Groundwater Discharge Permit
– Engineering / Hydrogeologic Reports
• MEPA-ENF: >10,000 GPD in Zone II
• MESA- Priority Habitat (8 moths and box
turtle)
• New Source Approval (new water supply
well)
• NOI – less than 100’ of Bumps Pond (well)
Horsley Witten Group, Inc.
5. Existing Influent
(Plymouth)
• Daily Flow – 13,000+ GPD
– 200 inmates
– 15 staff
• BOD – 358* mg/L (120 current longer term
influent data)
• TSS – 210 mg/L
• TKN - 124 mg/L
• Alkalinity 163 mg/L
*24 hour sample during design
Horsley Witten Group, Inc.
6. Design Effluent* (Plymouth)
• Daily Flow – 31,000 GPD
– 300 inmates
– 21 staff
• BOD <30 mg/L
• TSS – 10 mg/L
• Total Nitrogen <10 mg/L
*Based on DEP Interim Guidelines on Reclaimed Water (BRP/DWM/PeP/P00-3)
Horsley Witten Group, Inc.
18. MCI-Norfolk
• Existing 0.486MGD WWTP with Sanitaire
Package Treatment Units (PTUs) to Sand
Filter Beds then surface water discharge
• Interruption of Service Not Option
• Upgrade Required to meet new NPDES
Discharge Permit (discharge by 12/2012)
– BOD 7 mg/L
– Total Ammonia Nitrogen 1 mg/L
– Total Phosphorus 0.1 mg/L (April - Oct)
Horsley Witten Group, Inc.
20. Getting Started
•
•
•
•
•
(Norfolk)
HW hired by DCAM – March 2009
DEP Approved design – November 13, 2009
Bid Date – December 2009
Start Construction – February 2010
Start-up – March 2011
Horsley Witten Group, Inc.
22. Evaluate Technologies/Cost
(Norfolk)
• MBR Selected based on recent success at
Plymouth, and flexibility of installing MBR
without Interruption of Facility Operation
• Membrane - $7.7Million (DCAM accepted
contractor low bid)- *Includes Conversion of EQ
tanks, Headworks, UV, etc.
Horsley Witten Group, Inc.
23. UV
Effluent to UV
Sludge Wasting
Tanks
Existing EQ Tanks
(75,000 gal. each)
Existing
Office/Lab
New WWTP
(10,000 s.f)
0.5 MGD
Headworks
Coarse/Fine Screen
Distribution Box
Convert to Anerobic
Tank (200,000 gal.)
Convert PTU’s to EQ
(400,000 gal. total)
24. Train 1
To Anerobic Tank
Train 2
To Anerobic Tank
Influent
Anoxic Tank, Mixing &
Carbon Addition
Kaiser
Blowers
Aeration
Membrane
RAS
Permeate Pumps
(Under Vacuum)
Effluent to UV
RAS
Sludge Wasting
25. From “Sticks n Bricks” to the Real Thing
Horsley Witten Group, Inc.
30. Questions
• Anyone interested in touring either
facility let us know.
Joe Longo
jlongo@horsleywitten.com
Tom Lee
fplee@horsleywitten.com
508-833-6600
Horsley Witten Group, Inc.