SlideShare a Scribd company logo
1 of 38
A Presentation recupretor
Submitted to:
Dr. Erfan Uckan
Associate Professor
 Heat exchangers are practical devices used to
transfer energy from one fluid to another
 To get fluid streams to the right temperature for the
next process
– reactions often require feeds at high temp.
 To condense vapours
 To evaporate liquids
 To recover heat to use elsewhere
 To reject low-grade heat
 To drive a power cycle
What are heat exchangers for?
what is Recupretor
A recupretor is a one in which the two fluids are separated at all time by a solid barrier.
A recuperator is a special purpose counter flow energy recovery heat exchanger positioned
within the supply and exhaust air streams of an air handling system, or in the exhaust gases of
an industrial process, in order to recover the waste heat
Recuperators are often used in association with the burner portion of a heat engine, to increase
the overall efficiency. For example, in a gas turbine engine, air is compressed, mixed with fuel,
which is then burned and used to drive a turbine. The recuperator transfers some of the waste
heat in the exhaust to the compressed air, thus preheating it before entering the fuel burner
stage. Since the gases have been pre-heated, less fuel is needed to heat the gases up to the
turbine inlet temperature. By recovering some of the energy usually lost as waste heat, the
recuperator can make a heat engine or gas turbine significantly more efficient.
Heat exchangers
Recuperators Regenerators
Wall separating streams Direct contact
 Most heat exchangers have two streams, hot and cold, but
some have more than two
Main Categories Of
Exchanger
Recuperators/Regenerators
Other types of gas-to-gas heat exchangers
- Run around coil
-Thermal wheel, or rotary heat exchanger (including
- enthalpy wheel and desiccant wheel)
- Heat pipe
- Radiation Recuperator
- Convection Recuperator
Heat Recuperators
Air-to-Air, Air-Liquid-Air
The aim in a heat recuperator is to transfer the heat contained in the
dryer exhaust air to preheat the drying air. In principle, there are two
types of heat recuperating systems:
· Air-to-Air
· Air-Liquid-Air
- Process-Therm
- Hex-Tube
Both systems are incorporated after the cyclones. However, incorporating
a bag filter prior to the heat recuperator increases the efficiency, as
deposits on the heat surface cannot be completely avoided even with
correctly selected air velocities in the dust-loaded air. It is possible to
operate the recuperator several days without cleaning, but should it
prove necessary to clean the equipment, this is done by means of a
built-in CIP system.
Heat Recuperators
Niro offers two types of Air-Liquid-Air
heat recuperators:
• Process-Therm heat exchanger
• Hex-Tube heat exchanger
These units are much more flexible with
respect to retrofit installations. The air-
liquid-air heat recovery units consists of
two heat exchangers, one for heat transfer
between the dryer exhaust air and the
other, a finned tube heat exchanger for
preheating the inlet air to the dryer.
Typically water or water-glycol solution
is re-circulated between the two heat
exchangers as the heat transfer liquid. In
this type of heat recuperator the exhaust
air heat exchanger is placed after a bag
filter or a wet scrubber and the finned
tube heat exchanger is located after the
main inlet air filter to the dyer.
Both the Hex-Tube heat exchanger and
the Process-Therm heat recuperator units
can be cleaned during operation or shut
down and are supplied with CIP nozzles
and CIP manifold to connect to the dryer CIP system.
The thermal plates are assembled vertically
in compact plate banks with separation
between the plates. Exhaust air is passed
down between the plates and the heat
transfer liquid is re-circulated within the
plates. Heat transfer is a function of the
turbulence achieved in the gas stream; the
closer the plates , the higher the turbulence
and thus the heat transfer. A variable gap
allows the use of optimum conditions
avoiding the risk of plugging. The use
of individual liquid connectors allow the
plates to be isolated singly. This offers
ease of maintenance and operation but
also avoids the expense of total bank Process-Therm installation
Individual plate connections
Energy transfer process
Normally the heat transfer between airstreams provided
by the device is termed as 'sensible', which is the exchange
of energy, or enthalpy, resulting in a change in
temperature of the medium (air in this case), but with
no change in moisture content. However, if moisture or
relative humidity levels in the return air stream are high
enough to allow condensation to take place in the device,
then this will cause 'latent' heat to be released and the heat
transfer material will be covered with a film of water. Despite
a corresponding absorption of latent heat, as some
of the water film is evaporated in the opposite airstream,
the water will reduce the thermal resistance of the boundary
layer of the heat exchanger material and thus improve
the heat transfer coefficient of the device, and hence
increase
efficiency. The energy exchange of such devices
now comprises both sensible and latent heat transfer; in
addition to a change in temperature, there is also a
change
in moisture content of the exhaust air stream.
However, the film of condensation will also slightly
increase
pressure drop through the device, and depending
upon the spacing of the matrix material, this can increase
resistance by up to 30%. If the unit is not laid to falls, and
the condensate not allowed to drain properly, this will
increase
fan energy consumption and reduce the seasonal
efficiency of the device.
· Objectives:
– Design a lightweight recuperator applicable to FTT’s Advanced
Engine
Concept
– Perform a mock build of a recuperator demonstrator
· What is heat transfer?
– The process of heat exchange between two fluids operating under
different temperatures
– A device that implements this process is a heat exchanger
· What is a recuperator?
– Waste heat recovery heat exchanger
– Utilizes the hot turbine exit gases to heat a portion of cooler
compressor
discharge air and returns it to the combustor
– Reduces heat losses and therefore increases efficiency
Recuperators and regenerators recover heat from the turbine exhaust and use it to
preheat the air from
the compressor before it enters the combustor, thereby saving fuel. This heat
transfer While recuperators and regenerators are quite similar thermodynamically,
they are totally
different in design.
Recuperators are conventional heat exchangers in which hot and cold gases flow
steadily on opposite sides of a solid (usually metal) wall.
Regenerators are periodic-flow devices. Fluid streams flow in opposite directions
through passages in a
wheel with heat storage walls. The wheel rotates, transferring heat from one stream
to the other.
Regenerators usually use a nest of very small parallel passages oriented axially on a
wheel which rotates
In a similar manner, turbine reheat can be used to increase the power output of a large-pressure-ratio
turbine. This is the thermodynamic principle in turbojet afterburner firing. Turbine reheat increases
power, but decreases efficiency unless the turbine exhaust heat is used for additional power generation,
as
is the case with a combined cycle, or is used with a recuperator to preheat combustor inlet air.
Intercoolers and reheat burners increase the temperature difference between the compressor and
turbine discharges, thereby increasing the opportunity to use a recuperator to preheat the burner air
with
exhaust heat. An intercooled recuperated (ICR) machine is at present in development. The efficiency
decrease at part load of an ICR gas turbine is much less than of conventional simple cycle machines.
Small gas turbines have uncooled turbine blades as a result of the difficulty in manufacturing extremely
small cooling passages in small blades. This results in low efficiencies, making it difficult for such turbines
to compete with high-volume production (low-cost) reciprocating (piston) engines. The low-pressureratio
recuperated cycle has greater efficiency, although at higher cost. The recuperated cycle is finding
favor in programs for small (under 300-kW) gas turbines used for stationary power.
Because of their compact size, low emissions, and light weight, gas turbines are also being considered
for hybrid engine-battery vehicles. Proponents are pursuing the low-pressure-ratio recuperated gas
turbine as the way to obtain high efficiency and low emissions in a compact power plant.
An ingenious gas turbine cycle is the closed cycle in which the working fluid is sealed in the system.
Heat is added to the fluid with an externally fired heater and extracted from the fluid through heat
exchangers. The working fluid may be any gas, and the density of the gas may be varied—to vary the
power delivered by the machine—by using a gas storage cylinder connected to the compressor discharge
Use in metallurgical furnaces
Recuperators have also been used to recover heat from
waste gasses to preheat combustion air and fuel for many
years by metallic recuperators to reduce energy costs and
carbon footprint of operation. Compared to alternatives
such as regenerative furnaces, initial costs are lesser,
there
are no valves to be switching back and forth, there are no
induced-draft fans and it does not require a web of gas
ducts spread up all over the furnace.
Historically the recovery ratios of recuperators compared
to regenerative burners were low. However, recent
improvements
to technology have allowed recuperators to
recover 70-80% of the waste heat and pre-heated air up
to 850-900 deg C is now possible.
Use in microturbines
Recuperators can be used to increase the efficiency of gas
turbines for power generation, provided the exhaust gas
is hotter than the compressor outlet temperature. The exhaust
heat from the turbine is used to pre-heat the air from
the compressor before further heating in the combustor,
reducing the fuel input required. The larger the temperature
difference between turbine out and compressor out,
the greater the benefit from the recuperator. [1] Therefore,
microturbines (<1MW), which typically have low
pressure ratios, have the most to gain from the use of a recuperator.
In practice, a doubling of efficiency is possible
through the use of a recuperator.[2] The major practical
challenge for a recuperator in microturbine applications
is coping with the exhaust gas temperature, which can exceed
750C.
Use in ventilation systems
In heating, ventilation and air-conditioning systems,
HVAC, recuperators are commonly used to re-use waste
heat from exhaust air normally expelled to atmosphere.
Devices typically comprises a series of parallel plates of
aluminium, plastic, stainless steel, or synthetic fibre, alternate
pairs of which are enclosed on two sides to form
twin sets of ducts at right angles to each other, and which
contain the supply and extract air streams. In this manner
heat from the exhaust air stream is transferred through the
separating plates, and into the supply air stream. Manufacturers
claim gross efficiencies of up to 80% depending
upon the specification of the unit.
The characteristics of this device are attributable to the
relationship between the physical size of the unit, in particular
the air path distance, and the spacing of the plates.
For an equal air pressure drop through the device, a small
unit will have a narrower plate spacing and a lower air

More Related Content

What's hot (20)

Waste Heat Recovery Devices by Varun Pratap Singh
Waste Heat Recovery Devices by Varun Pratap SinghWaste Heat Recovery Devices by Varun Pratap Singh
Waste Heat Recovery Devices by Varun Pratap Singh
 
Boiler
BoilerBoiler
Boiler
 
Fouling effects on boiler
Fouling effects on boilerFouling effects on boiler
Fouling effects on boiler
 
Steam generator part 1
Steam generator part 1Steam generator part 1
Steam generator part 1
 
Heat exchangers
Heat exchangersHeat exchangers
Heat exchangers
 
Cooling towers in thermal power plants
Cooling towers in thermal power plantsCooling towers in thermal power plants
Cooling towers in thermal power plants
 
presentation on heat exchanger
presentation on  heat exchangerpresentation on  heat exchanger
presentation on heat exchanger
 
Formation and properties of steam
Formation and properties of steamFormation and properties of steam
Formation and properties of steam
 
Uppload chap 5 convection heat trasnfer
Uppload chap  5 convection heat trasnferUppload chap  5 convection heat trasnfer
Uppload chap 5 convection heat trasnfer
 
Heat Exchangers
Heat ExchangersHeat Exchangers
Heat Exchangers
 
Plate heat exchanger
Plate heat exchangerPlate heat exchanger
Plate heat exchanger
 
Heat exchangers
Heat exchangersHeat exchangers
Heat exchangers
 
Steam distribution system, utilization and design
Steam distribution system, utilization and designSteam distribution system, utilization and design
Steam distribution system, utilization and design
 
Diesel power plant
Diesel power plantDiesel power plant
Diesel power plant
 
Heat Exchanger
Heat ExchangerHeat Exchanger
Heat Exchanger
 
[PPT] on Steam Turbine
[PPT] on Steam Turbine[PPT] on Steam Turbine
[PPT] on Steam Turbine
 
Feedwater heaters in thermal power plants
Feedwater heaters in thermal power plantsFeedwater heaters in thermal power plants
Feedwater heaters in thermal power plants
 
Heat exchangers
Heat exchangers  Heat exchangers
Heat exchangers
 
Steam ejector working principle
Steam ejector working principleSteam ejector working principle
Steam ejector working principle
 
Super critical boiler
Super critical boilerSuper critical boiler
Super critical boiler
 

Viewers also liked (7)

Recupretor
RecupretorRecupretor
Recupretor
 
WASTE HEAT RECOVERY SYSTEM
WASTE HEAT RECOVERY SYSTEMWASTE HEAT RECOVERY SYSTEM
WASTE HEAT RECOVERY SYSTEM
 
Presentation on Heat pump and its Function.
Presentation on Heat pump and its Function.Presentation on Heat pump and its Function.
Presentation on Heat pump and its Function.
 
HEAT RECOVERY VENTILATORS
HEAT RECOVERY VENTILATORSHEAT RECOVERY VENTILATORS
HEAT RECOVERY VENTILATORS
 
Waste Heat Recovery Vinay Shukla
Waste Heat Recovery  Vinay ShuklaWaste Heat Recovery  Vinay Shukla
Waste Heat Recovery Vinay Shukla
 
Heat exchangers and types
Heat exchangers and typesHeat exchangers and types
Heat exchangers and types
 
Heat pump presentation
Heat pump presentation Heat pump presentation
Heat pump presentation
 

Similar to Heat Exchanger recuperators

2013edusat lecture on steam plant(2)
2013edusat lecture on steam  plant(2)2013edusat lecture on steam  plant(2)
2013edusat lecture on steam plant(2)iimt college meerut
 
WORKING OF HEAT PUMPS WITH (CO2) REFRIGERANT
WORKING OF HEAT PUMPS WITH (CO2) REFRIGERANT WORKING OF HEAT PUMPS WITH (CO2) REFRIGERANT
WORKING OF HEAT PUMPS WITH (CO2) REFRIGERANT Swathi Rampur
 
Waste Heat Recovery
Waste Heat RecoveryWaste Heat Recovery
Waste Heat Recoveryrajputdanish
 
Waste Heat Recovery Publication
Waste Heat Recovery PublicationWaste Heat Recovery Publication
Waste Heat Recovery Publicationrajputdanish
 
Thermal power plant
Thermal power plantThermal power plant
Thermal power plantfoxycrow
 
Thermal power station
Thermal power stationThermal power station
Thermal power stationvishal gupta
 
Gas turbine cycle (open and closed gas turbine cycle)
Gas turbine cycle (open and closed gas turbine cycle)Gas turbine cycle (open and closed gas turbine cycle)
Gas turbine cycle (open and closed gas turbine cycle)Abhishek Choksi
 
GAS TURBINE POWER PLANT - SNIST
GAS TURBINE POWER PLANT - SNISTGAS TURBINE POWER PLANT - SNIST
GAS TURBINE POWER PLANT - SNISTS.Vijaya Bhaskar
 
a). EconomiserAn economiser is a mechanical device which is used a.pdf
a). EconomiserAn economiser is a mechanical device which is used a.pdfa). EconomiserAn economiser is a mechanical device which is used a.pdf
a). EconomiserAn economiser is a mechanical device which is used a.pdfrajat630669
 
Waste Heat Recovery from refregeration cycle
Waste Heat Recovery from refregeration cycleWaste Heat Recovery from refregeration cycle
Waste Heat Recovery from refregeration cycleMukesh pratap Singh
 
NTPC ,sipat voccational training
NTPC ,sipat voccational trainingNTPC ,sipat voccational training
NTPC ,sipat voccational trainingbhumit1
 
Academic project report
Academic project reportAcademic project report
Academic project reportravi wankhede
 
2015_Doble Paper
2015_Doble Paper2015_Doble Paper
2015_Doble PaperKevin Riley
 
Air preheater hot air generator manufacturer
Air preheater   hot air generator manufacturerAir preheater   hot air generator manufacturer
Air preheater hot air generator manufacturerPreeti Agarwal
 
Chapter waste heat recovery p18
Chapter waste heat recovery p18Chapter waste heat recovery p18
Chapter waste heat recovery p18Nikolay Mavrodiev
 

Similar to Heat Exchanger recuperators (20)

lecture on steam plant
 lecture on steam  plant lecture on steam  plant
lecture on steam plant
 
I42046063
I42046063I42046063
I42046063
 
2013edusat lecture on steam plant(2)
2013edusat lecture on steam  plant(2)2013edusat lecture on steam  plant(2)
2013edusat lecture on steam plant(2)
 
WORKING OF HEAT PUMPS WITH (CO2) REFRIGERANT
WORKING OF HEAT PUMPS WITH (CO2) REFRIGERANT WORKING OF HEAT PUMPS WITH (CO2) REFRIGERANT
WORKING OF HEAT PUMPS WITH (CO2) REFRIGERANT
 
STEAM POWER PLANT
STEAM POWER PLANTSTEAM POWER PLANT
STEAM POWER PLANT
 
Waste Heat Recovery
Waste Heat RecoveryWaste Heat Recovery
Waste Heat Recovery
 
Waste Heat Recovery Publication
Waste Heat Recovery PublicationWaste Heat Recovery Publication
Waste Heat Recovery Publication
 
Thermal power plant
Thermal power plantThermal power plant
Thermal power plant
 
Thermal power station
Thermal power stationThermal power station
Thermal power station
 
Gas turbine cycle (open and closed gas turbine cycle)
Gas turbine cycle (open and closed gas turbine cycle)Gas turbine cycle (open and closed gas turbine cycle)
Gas turbine cycle (open and closed gas turbine cycle)
 
GAS TURBINE POWER PLANT - SNIST
GAS TURBINE POWER PLANT - SNISTGAS TURBINE POWER PLANT - SNIST
GAS TURBINE POWER PLANT - SNIST
 
a). EconomiserAn economiser is a mechanical device which is used a.pdf
a). EconomiserAn economiser is a mechanical device which is used a.pdfa). EconomiserAn economiser is a mechanical device which is used a.pdf
a). EconomiserAn economiser is a mechanical device which is used a.pdf
 
Waste Heat Recovery from refregeration cycle
Waste Heat Recovery from refregeration cycleWaste Heat Recovery from refregeration cycle
Waste Heat Recovery from refregeration cycle
 
NTPC ,sipat voccational training
NTPC ,sipat voccational trainingNTPC ,sipat voccational training
NTPC ,sipat voccational training
 
Academic project report
Academic project reportAcademic project report
Academic project report
 
2015_Doble Paper
2015_Doble Paper2015_Doble Paper
2015_Doble Paper
 
Air preheater hot air generator manufacturer
Air preheater   hot air generator manufacturerAir preheater   hot air generator manufacturer
Air preheater hot air generator manufacturer
 
Airpreheater ppt
Airpreheater pptAirpreheater ppt
Airpreheater ppt
 
Airpreheater ppt
Airpreheater pptAirpreheater ppt
Airpreheater ppt
 
Chapter waste heat recovery p18
Chapter waste heat recovery p18Chapter waste heat recovery p18
Chapter waste heat recovery p18
 

Heat Exchanger recuperators

  • 1. A Presentation recupretor Submitted to: Dr. Erfan Uckan Associate Professor
  • 2.  Heat exchangers are practical devices used to transfer energy from one fluid to another  To get fluid streams to the right temperature for the next process – reactions often require feeds at high temp.  To condense vapours  To evaporate liquids  To recover heat to use elsewhere  To reject low-grade heat  To drive a power cycle What are heat exchangers for?
  • 3. what is Recupretor A recupretor is a one in which the two fluids are separated at all time by a solid barrier. A recuperator is a special purpose counter flow energy recovery heat exchanger positioned within the supply and exhaust air streams of an air handling system, or in the exhaust gases of an industrial process, in order to recover the waste heat Recuperators are often used in association with the burner portion of a heat engine, to increase the overall efficiency. For example, in a gas turbine engine, air is compressed, mixed with fuel, which is then burned and used to drive a turbine. The recuperator transfers some of the waste heat in the exhaust to the compressed air, thus preheating it before entering the fuel burner stage. Since the gases have been pre-heated, less fuel is needed to heat the gases up to the turbine inlet temperature. By recovering some of the energy usually lost as waste heat, the recuperator can make a heat engine or gas turbine significantly more efficient.
  • 4. Heat exchangers Recuperators Regenerators Wall separating streams Direct contact  Most heat exchangers have two streams, hot and cold, but some have more than two Main Categories Of Exchanger
  • 6.
  • 7. Other types of gas-to-gas heat exchangers - Run around coil -Thermal wheel, or rotary heat exchanger (including - enthalpy wheel and desiccant wheel) - Heat pipe - Radiation Recuperator - Convection Recuperator
  • 9. The aim in a heat recuperator is to transfer the heat contained in the dryer exhaust air to preheat the drying air. In principle, there are two types of heat recuperating systems: · Air-to-Air · Air-Liquid-Air - Process-Therm - Hex-Tube Both systems are incorporated after the cyclones. However, incorporating a bag filter prior to the heat recuperator increases the efficiency, as deposits on the heat surface cannot be completely avoided even with correctly selected air velocities in the dust-loaded air. It is possible to operate the recuperator several days without cleaning, but should it prove necessary to clean the equipment, this is done by means of a built-in CIP system. Heat Recuperators
  • 10.
  • 11. Niro offers two types of Air-Liquid-Air heat recuperators: • Process-Therm heat exchanger • Hex-Tube heat exchanger These units are much more flexible with respect to retrofit installations. The air- liquid-air heat recovery units consists of two heat exchangers, one for heat transfer between the dryer exhaust air and the other, a finned tube heat exchanger for preheating the inlet air to the dryer. Typically water or water-glycol solution is re-circulated between the two heat exchangers as the heat transfer liquid. In this type of heat recuperator the exhaust air heat exchanger is placed after a bag filter or a wet scrubber and the finned tube heat exchanger is located after the main inlet air filter to the dyer. Both the Hex-Tube heat exchanger and the Process-Therm heat recuperator units can be cleaned during operation or shut down and are supplied with CIP nozzles and CIP manifold to connect to the dryer CIP system.
  • 12. The thermal plates are assembled vertically in compact plate banks with separation between the plates. Exhaust air is passed down between the plates and the heat transfer liquid is re-circulated within the plates. Heat transfer is a function of the turbulence achieved in the gas stream; the closer the plates , the higher the turbulence and thus the heat transfer. A variable gap allows the use of optimum conditions avoiding the risk of plugging. The use of individual liquid connectors allow the plates to be isolated singly. This offers ease of maintenance and operation but also avoids the expense of total bank Process-Therm installation Individual plate connections
  • 13.
  • 14.
  • 15. Energy transfer process Normally the heat transfer between airstreams provided by the device is termed as 'sensible', which is the exchange of energy, or enthalpy, resulting in a change in temperature of the medium (air in this case), but with no change in moisture content. However, if moisture or relative humidity levels in the return air stream are high enough to allow condensation to take place in the device, then this will cause 'latent' heat to be released and the heat transfer material will be covered with a film of water. Despite a corresponding absorption of latent heat, as some of the water film is evaporated in the opposite airstream, the water will reduce the thermal resistance of the boundary layer of the heat exchanger material and thus improve the heat transfer coefficient of the device, and hence increase efficiency. The energy exchange of such devices now comprises both sensible and latent heat transfer; in addition to a change in temperature, there is also a change in moisture content of the exhaust air stream. However, the film of condensation will also slightly increase pressure drop through the device, and depending upon the spacing of the matrix material, this can increase resistance by up to 30%. If the unit is not laid to falls, and the condensate not allowed to drain properly, this will increase fan energy consumption and reduce the seasonal efficiency of the device.
  • 16. · Objectives: – Design a lightweight recuperator applicable to FTT’s Advanced Engine Concept – Perform a mock build of a recuperator demonstrator · What is heat transfer? – The process of heat exchange between two fluids operating under different temperatures – A device that implements this process is a heat exchanger · What is a recuperator? – Waste heat recovery heat exchanger – Utilizes the hot turbine exit gases to heat a portion of cooler compressor discharge air and returns it to the combustor – Reduces heat losses and therefore increases efficiency
  • 17.
  • 18.
  • 19.
  • 20.
  • 21.
  • 22.
  • 23.
  • 24.
  • 25.
  • 26. Recuperators and regenerators recover heat from the turbine exhaust and use it to preheat the air from the compressor before it enters the combustor, thereby saving fuel. This heat transfer While recuperators and regenerators are quite similar thermodynamically, they are totally different in design. Recuperators are conventional heat exchangers in which hot and cold gases flow steadily on opposite sides of a solid (usually metal) wall. Regenerators are periodic-flow devices. Fluid streams flow in opposite directions through passages in a wheel with heat storage walls. The wheel rotates, transferring heat from one stream to the other. Regenerators usually use a nest of very small parallel passages oriented axially on a wheel which rotates
  • 27.
  • 28. In a similar manner, turbine reheat can be used to increase the power output of a large-pressure-ratio turbine. This is the thermodynamic principle in turbojet afterburner firing. Turbine reheat increases power, but decreases efficiency unless the turbine exhaust heat is used for additional power generation, as is the case with a combined cycle, or is used with a recuperator to preheat combustor inlet air. Intercoolers and reheat burners increase the temperature difference between the compressor and turbine discharges, thereby increasing the opportunity to use a recuperator to preheat the burner air with exhaust heat. An intercooled recuperated (ICR) machine is at present in development. The efficiency decrease at part load of an ICR gas turbine is much less than of conventional simple cycle machines. Small gas turbines have uncooled turbine blades as a result of the difficulty in manufacturing extremely small cooling passages in small blades. This results in low efficiencies, making it difficult for such turbines to compete with high-volume production (low-cost) reciprocating (piston) engines. The low-pressureratio recuperated cycle has greater efficiency, although at higher cost. The recuperated cycle is finding favor in programs for small (under 300-kW) gas turbines used for stationary power. Because of their compact size, low emissions, and light weight, gas turbines are also being considered for hybrid engine-battery vehicles. Proponents are pursuing the low-pressure-ratio recuperated gas turbine as the way to obtain high efficiency and low emissions in a compact power plant. An ingenious gas turbine cycle is the closed cycle in which the working fluid is sealed in the system. Heat is added to the fluid with an externally fired heater and extracted from the fluid through heat exchangers. The working fluid may be any gas, and the density of the gas may be varied—to vary the power delivered by the machine—by using a gas storage cylinder connected to the compressor discharge
  • 29.
  • 30.
  • 31.
  • 32.
  • 33.
  • 34.
  • 35.
  • 36. Use in metallurgical furnaces Recuperators have also been used to recover heat from waste gasses to preheat combustion air and fuel for many years by metallic recuperators to reduce energy costs and carbon footprint of operation. Compared to alternatives such as regenerative furnaces, initial costs are lesser, there are no valves to be switching back and forth, there are no induced-draft fans and it does not require a web of gas ducts spread up all over the furnace. Historically the recovery ratios of recuperators compared to regenerative burners were low. However, recent improvements to technology have allowed recuperators to recover 70-80% of the waste heat and pre-heated air up to 850-900 deg C is now possible.
  • 37. Use in microturbines Recuperators can be used to increase the efficiency of gas turbines for power generation, provided the exhaust gas is hotter than the compressor outlet temperature. The exhaust heat from the turbine is used to pre-heat the air from the compressor before further heating in the combustor, reducing the fuel input required. The larger the temperature difference between turbine out and compressor out, the greater the benefit from the recuperator. [1] Therefore, microturbines (<1MW), which typically have low pressure ratios, have the most to gain from the use of a recuperator. In practice, a doubling of efficiency is possible through the use of a recuperator.[2] The major practical challenge for a recuperator in microturbine applications is coping with the exhaust gas temperature, which can exceed 750C.
  • 38. Use in ventilation systems In heating, ventilation and air-conditioning systems, HVAC, recuperators are commonly used to re-use waste heat from exhaust air normally expelled to atmosphere. Devices typically comprises a series of parallel plates of aluminium, plastic, stainless steel, or synthetic fibre, alternate pairs of which are enclosed on two sides to form twin sets of ducts at right angles to each other, and which contain the supply and extract air streams. In this manner heat from the exhaust air stream is transferred through the separating plates, and into the supply air stream. Manufacturers claim gross efficiencies of up to 80% depending upon the specification of the unit. The characteristics of this device are attributable to the relationship between the physical size of the unit, in particular the air path distance, and the spacing of the plates. For an equal air pressure drop through the device, a small unit will have a narrower plate spacing and a lower air