Gopi Chandra Sahu is seeking a position in power plant operation and maintenance with over 9 years of experience in commissioning, operation, and maintenance of pulverized coal fired power plants. He holds an MBA, BE in Mechanical Engineering, and a Boiler Operation Engineer certificate. Currently he works as an Assistant Manager and Shift Incharge at a 540MW power plant in Wardha, India, where he leads a team in safe plant operation and addresses operational issues. Previously he has worked at other thermal power plants in engineering roles focused on automation and controls.
Thermal Power plant familarisation & its AuxillariesVaibhav Paydelwar
PPT in Relation to Power Plant familarisation, Coal to Electricity Basics,Power Plant cycles, Concepts of Supercritical Technology Boiler, Concepts Of BTG Package as well as Balance of Plant
A thermal power station is a power station in which heat energy is converted to electric power. In most of the places in the world the turbine is steam-driven. Water is heated, turns into steam and spins a steam turbine which drives an electrical generator.
Operational description of 400kv switchyard NTPC Ramagundam RSTPSPradeep Avanigadda
400 KV Switchyard of Ramagundam Super Thermal Power Station is the most vital switching station in the southern Grid. 2600 MW of Bulk Power generated by three 200 MW Units and four 500 MW Units of NTPC Ramagundam is evacuated for supplying to the southern states.
Switchyard consists of four 400 KV busbars fed by 7 Nos. of generators, 10 Nos. of 400 KV feeders, 3 Nos of 220 KV feeders and two nos. of 132 Kv feeders as shown in the single line diagram of 400 Kv switch yard.
In addition to the above, four nos. of Tie Transformers, five nos. of Auto transformers, two nos. of Shunt Reactors and one Bus reactor are provided.
Turbine Stress Control Logic, Calculation & WorkingTahoor Alam Khan
Turbine Stress Control is one of the complex logics of BHEL turbine. This presentation clearly explains the Logic, working, calculations and influence of the same on operation of steam turbine. For further details and understanding, I can be reached on tahoorkhn03@gmail.com.
The writeup details the Heat Balance of BHEL 210 MW Turbine Cycle. The Input and Output steam condition of Turbines, Extractions, Deaerator, LP Heaters, Condensers etc have been computed as per the specifications of the turbine manufacturer
Thermal Power plant familarisation & its AuxillariesVaibhav Paydelwar
PPT in Relation to Power Plant familarisation, Coal to Electricity Basics,Power Plant cycles, Concepts of Supercritical Technology Boiler, Concepts Of BTG Package as well as Balance of Plant
A thermal power station is a power station in which heat energy is converted to electric power. In most of the places in the world the turbine is steam-driven. Water is heated, turns into steam and spins a steam turbine which drives an electrical generator.
Operational description of 400kv switchyard NTPC Ramagundam RSTPSPradeep Avanigadda
400 KV Switchyard of Ramagundam Super Thermal Power Station is the most vital switching station in the southern Grid. 2600 MW of Bulk Power generated by three 200 MW Units and four 500 MW Units of NTPC Ramagundam is evacuated for supplying to the southern states.
Switchyard consists of four 400 KV busbars fed by 7 Nos. of generators, 10 Nos. of 400 KV feeders, 3 Nos of 220 KV feeders and two nos. of 132 Kv feeders as shown in the single line diagram of 400 Kv switch yard.
In addition to the above, four nos. of Tie Transformers, five nos. of Auto transformers, two nos. of Shunt Reactors and one Bus reactor are provided.
Turbine Stress Control Logic, Calculation & WorkingTahoor Alam Khan
Turbine Stress Control is one of the complex logics of BHEL turbine. This presentation clearly explains the Logic, working, calculations and influence of the same on operation of steam turbine. For further details and understanding, I can be reached on tahoorkhn03@gmail.com.
The writeup details the Heat Balance of BHEL 210 MW Turbine Cycle. The Input and Output steam condition of Turbines, Extractions, Deaerator, LP Heaters, Condensers etc have been computed as per the specifications of the turbine manufacturer
1. MBA(PGDIM), B.E.(MECH.), BOE CERTIFICATE Power plant operation
`
`
GOPI CHANDRA SAHU
Ph. No. : - +91-7757035921,+91-8975144928, +91-7697913150
Passport No. L6340183
E-mail:- gopisahu333@gmail.com
Near Shaheed garden, Beside anil bekary ,
Vindhya Washni Ward, Tahsil:- Dhamtari
Post Office:- Dhamtari, Dist.:- Dhamtari
State:- Chhattisgarh, Pin no. 493773
CAREER OBJECTIVE
“Seeking a Position to utilize my skills and ability in the field of power plant
Operation and maintenance in the organization that offers Professional growth
while being Resourceful and innovative.”
EDUCATIONAND CERTIFICATION
MBA (PGDIM) from Indira Gandhi Open University New Delhi in 2010 with 1st
class 60.22%.
B.E. Mechanical from Pt. Ravisanker Sukla University Raipur in 2007, with 1st class
CPI, 7.25 (72.5%).
12th from Sarashwati Higher Secondary School Dhamtari in 2003 with 2nd class
59.2%.
10th Govt. Higher Secondary School Antagarh in 2001 with 1st class 60.6%.
Boiler Operation Engineer (BOE) certificate from Andhra Pradesh Government.
TOTAL EXPERIENCEIN PULVERIZED COAL (PF)FIRED POWER
PLANT 9th YEAR’S IN COMMISSIONING,OPERATION&
MANTENANCE
COMMISSIONING
Trail run of equipments, pre commissioning test (air & gas tightness or leakage),
Alkali boil out, thermal flow test, chemical cleaning (water washing alkali, alkali boil
out & rinsing boil out, acid cleaning of boiler, 1st stage preservation, 2nd stage
preservation), steam blowing, safety valve setting, hydraulic test, wet preservation,
preparation of first light up (Air system, gas system, water system, fuel steam, FSSS
system), Lubrication and governing system (oil flushing and hydraulic test, bearing
inspection of turbine, governing system baring gear, vacuum tightness test.
2. MBA(PGDIM), B.E.(MECH.), BOE CERTIFICATE Power plant operation
`OPERATION
540 MW (4*135), 160 MW (2*80) & 2650 MW (2*660, 4*250, 3*110)
Presently working as an Assistant Manager (Unit Controller / Shift In charge)
in SAI WARDHA POWER LTD- WARORA, from 18th June 2014 to till date. It
has 540 MW (4*135) CPP and IPP power plant; with PF Boiler
Boiler make: Dong Fang Electric Corporation, China.
Specifications: PF Boiler of 440TPH Steam generating capacity at 13.73 Mpa
Pressure and 540 deg. C with Reheat at pressure at 2.73 Mpa & 540m Deg C temp.
Turbine make: Dong Fang Electric Corporation, china.
Type: Extra High Pressure, single Shaft, Double Cylinder, Double Flow, One
Intermediate Reheat, condensed Type.
Specifications: Capacity 135 MW, 398.9 TPH steam inlet at 13.24 Mpa and 535
deg. C.
Worked as Executive Engineer (DCS Engineer) in HINDUSTAN ZINC LTD. –
DARIBA, Under WARSTILA INDIA LTD. (O&M), from 25th September 2009 to
10th June 2014. It has 160 MW (2*80) Captive power plants; with pulverize Boiler
2*320 TPH, Boiler, Turbine & Generator make- BHEL, Working pressure 94
kg/cm2 & Temp. 540 C, Mill - Medium speed Pressurized Bowl Mill (XRP-623) ,
automation DCS (EMERSON & MAX DNA).
Worked as an Engineer (DCS Engineer) in chhabra thermal power plant under
Instrumentation Limited (O&M) from 24/12/2007 to 21/09/2009. It has 2650
MW (2*660, 4*250, and 3*110) power plant, with pulverize Boiler and natural gas
based plant, knowledge of TD BFP/MD BFP, Hydrogen cooling/oil sealing,
Boiler Force circulation/ BCP, Primary water (DM Water) for cooling.
JOB RESPONSIBILITIES (UNIT CONTROLLER / SHIFT INCHARGE)
Lead a team of power plant professionals for safe operation of plant.
Guide control desk operators and Field operators for day-today operation.
Analyze operation roblem, in routine observation and corrective actions.
Emergency handling and risk management during exigency. Co-ordination with
Load Despatch canter and regulatory body for control of power generation.
Manage Manpower availability and equipment availability.
Operation of thermal power plants (BTG), and Balance of Plant (BOP) with
optimum efficiency and defect monitoring
Cold Start up, Warm start up, Hot Start-up, Very Hot Start-up, Normal
Operation, Emergency Handling like unit blackout ,home load, equipment
trappings and Safe start-up /shut down and load throw-off to control generation
as per requirement of Units.
Line up of the unit and its auxiliaries, Change-over of equipments, routine
testing of protection system.
3. MBA(PGDIM), B.E.(MECH.), BOE CERTIFICATE Power plant operation
`
Issue and cancellation PTW (Permit to Work) system with LOTOTO, safe
isolation, personnel safety and equipment safety.
Emergency Equipment Trial and restoration/isolation of process and Equipment
Preparation of daily reports & MIS reports.
Focusing on how Specific coal consumption & APC can be controlled.
Focusing on efficient operation of power plant, performing daily shift routine
activities.
Management of Coal & its blending & Ash Handling.
Daily efficiency & defect monitoring of power plant.
Manage Shift management of the Junior Engineer.
COMPUTERSKILL
MS-Office (Excel , World & Power Point)
SAP
IFS
Auto Cad 2004
Internet Browsing
PERSONAL
Name - Gopi Chandra Sahu
Father's Name – Mr. Vishnu Ram Sahu
Father's Designation – Government Job
DOB – 10/10/1984
States – Male
Marital States – Married
Current CTC – 8.76 Lakh Per annum
Expected CTC – Negotiable
DECLARATION
I do hereby declare that the above written particulars are to the best of my
knowledge and belief.
Date: -…………… Signature