SlideShare a Scribd company logo
1 of 66
Download to read offline
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 1 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
PRODUCTS AND SERVICES CATALOGUE 
Contents 
1 POWER QUALITY ANALYSERS ...................................................................................... 4 
1.1 GRIDSENSE POWERMONIC ............................................................................. 4 
1.1.1 Introduction ......................................................................................................... 4 
1.1.2 Key Features ...................................................................................................... 4 
1.1.3 Current Sensor Options ...................................................................................... 5 
1.1.4 Specifications ..................................................................................................... 5 
1.2 SUIN SA2100 ...................................................................................................... 7 
1.2.1 Introduction ......................................................................................................... 7 
1.2.2 Key Features ...................................................................................................... 7 
1.2.3 Current Sensor Options ...................................................................................... 7 
1.2.4 Voltage Leads .................................................................................................... 9 
1.2.5 Flexible Current Probe ..................................................................................... 10 
1.2.6 Carry Bag ......................................................................................................... 10 
1.2.7 Kit Items............................................................................................................ 10 
1.2.8 Specifications ................................................................................................... 11 
1.3 ZES ZIMMER LMG500 ...................................................................................... 13 
1.3.1 Introduction ....................................................................................................... 13 
1.3.2 Key Features .................................................................................................... 13 
1.3.3 Device Interface ............................................................................................... 14 
1.3.4 Connections ..................................................................................................... 15 
2 LOGGING INSTRUMENTS ............................................................................................. 16 
2.1 LOAD LOGGER ................................................................................................ 16 
2.1.1 Introduction ....................................................................................................... 16 
2.1.2 Specifications ................................................................................................... 16 
2.1.3 Installation ........................................................................................................ 17 
2.1.4 Software ........................................................................................................... 17 
2.1.5 Calibration ........................................................................................................ 17 
3 REMOTE (ONLINE) MONITORING SYSTEMS ............................................................... 18 
3.1 LOAD REMOTE ................................................................................................ 18 
3.2 MONITORING BACK-UP GENERATORS ......................................................... 19 
3.2.1 G8500 SINGLE GENERATOR SYSTEM ......................................................... 20 
3.2.2 G8600 MULTIPLE GENERATOR SYSTEM .................................................... 21 
3.2.3 G8700 MOBILE GENERATOR SYSTEM ........................................................ 22 
3.2.4 G8800 RESIDENTIAL GENERATOR SYSTEM .............................................. 23 
4 CURRENT PROBES AND SENSORS ............................................................................. 24 
4.1 FLEXIBLE CURRENT SENSORS ..................................................................... 24 
4.2 CLAMP ON CURRENT SENSORS ................................................................... 26 
4.3 MINIATURE SPLIT-CORE CURRENT TRANSFORMERS ................................ 28 
4.3.1 Key Features and General Specifications ........................................................ 28 
4.3.2 Range ............................................................................................................... 28
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 2 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
4.4 SUBSTATION CURRENT TRANSFORMER CONVERTERS ............................ 29 
4.4.1 Introduction ....................................................................................................... 29 
4.4.2 Specifications ................................................................................................... 29 
5 INSTRUMENT CURRENT TRANSFORMERS ................................................................ 30 
5.1 METERING ....................................................................................................... 31 
5.1.1 Measuring - PVC .............................................................................................. 31 
5.1.2 Measuring - MBQ Series .................................................................................. 32 
5.1.3 Measuring - MSQ Series .................................................................................. 33 
5.1.4 Measuring - Tape Insulated Ring Type - KTM Series ...................................... 35 
5.1.5 Measuring - Resin Cast Ring Type - KRM Series ............................................ 38 
5.1.6 Measuring - Resin Cast Ring Type - KSM Series ............................................ 40 
5.2 PROTECTION ................................................................................................... 42 
5.2.1 Protection - PVC ............................................................................................... 42 
5.2.2 Protection - Tape Insulated Ring Type - KTP Series ....................................... 43 
5.2.3 Protection - Resin Cast Ring Type - KRP Series ............................................. 45 
5.2.4 Protection - Resin Cast Ring Type - KSP Series ............................................. 47 
5.3 SPECIAL PURPOSE ......................................................................................... 48 
5.3.1 Summation Current Transformer ..................................................................... 48 
5.3.2 Interposing Current Transformer ...................................................................... 48 
5.3.3 Core Balance Current Transformer .................................................................. 49 
6 MEDIUM VOLTAGE PRODUCTS ................................................................................... 50 
6.1 MONITORING PRODUCTS .............................................................................. 50 
6.1.1 Cable Mounted Sensor ..................................................................................... 50 
6.1.2 Pole Mounted Sensor ....................................................................................... 51 
6.2 INDOOR AND OUTDOOR VOLTAGE TRANSFORMERS ................................ 53 
6.2.1 Indoor Single Phase Single Pole Voltage Transformers .................................. 53 
6.2.2 Indoor Single Phase Double Pole Voltage and Control Transformers ............. 54 
6.2.3 Indoor Voltage Three Phase Voltage Transformers ........................................ 55 
6.2.4 Draw-Out Voltage Transformers ...................................................................... 57 
6.2.5 Outdoor Voltage and Control Transformers ..................................................... 57 
6.2.6 Outdoor Metering Units .................................................................................... 58 
6.3 INDOOR AND OUTDOOR CURRENT TRANSFORMERS ................................ 58 
6.3.1 Indoor Ring Type, Window Type and Bus Duct (up to 36kV) .......................... 58 
6.3.2 Indoor Bar Primary Current Transformers (up to 36kV) ................................... 59 
6.3.3 Indoor Wound Primary (block Type) Current Transformers (up to 36kV) ........ 60 
6.3.4 Outdoor Current Transformers ......................................................................... 61 
7 POWER QUALITY MITIGATION PRODUCTS ................................................................ 62 
7.1 REACTORS AND FILTERS ............................................................................... 62 
7.2 POWER FACTOR CORRECTION UNITS ......................................................... 62 
7.3 ACTIVE HARMONIC FILTERING ...................................................................... 63 
8 CONSULTING AND SERVICES ...................................................................................... 65 
8.1 CONSULTING IN POWER QUALITY ................................................................ 65 
8.1.1 Power Quality Investigation .............................................................................. 65 
8.1.2 Power Quality Mitigation ................................................................................... 65 
8.1.3 Power Quality Management ............................................................................. 65
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 3 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
8.2 TRAINING ......................................................................................................... 65 
8.2.1 Product Training ............................................................................................... 65 
8.2.2 Professional Training ........................................................................................ 65 
8.3 TECHNICAL SUPPORT .................................................................................... 65 
8.3.1 Product Support ............................................................................................... 65 
8.3.2 Calibration and Repairs .................................................................................... 65 
8.4 LOW VOLUME CONTRACT MANUFACTURING .............................................. 66 
8.5 ENGINEERING AND PROJECT MANAGEMENT SERVICES .......................... 66 
8.5.1 Feature Requests and New Features .............................................................. 66 
8.5.2 Design .............................................................................................................. 66
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 4 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
1 Power Quality Analysers 
1.1 GridSense Powermonic 
1.1.1 Introduction 
The PowerMonic range of portable power recorders offers comprehensive and reliable monitoring of low voltage circuits. Built with high performance, toughness and focus on ease of use, the PowerMonic has been adopted as the workhorse instrument for a variety of power monitoring applications including power quality analysis, supply compliance checks, power flow studies, energy audits and voltage investigations. The PM45 is the latest addition to the PowerMonic product line, meeting CATIV-600V safety certification and voltage measurement standards. With four voltage and current channels, the PM45 records a trend over time along with a range of power quality parameters, including flicker, harmonics, power and imbalance in accordance to the latest IEC standards. 
The PM45 is also an independent event recorder capturing high resolution snapshots of fluctuations including motor starts, spikes and transients based on voltage and current limit settings. Utilized for short and long term power monitoring applications, the PM45 is typically installed on pad mount and pole mount transformers, capacitor banks, regulators, distribution substations, as well as commercial, residential and industrial connection points. 
Since its introduction in 1995, the PowerMonic has proven to be a reliable and versatile everyday instrument used worldwide by System Planners, Distribution Engineers, Electrical Engineers, Electrical Contractors, Power Quality Engineers, and Maintenance Engineers alike. 
1.1.2 Key Features 
 Up to eight (8) input channels [four (4) voltage and four (4) current] 
 Power profiling with high-speed event capture 
 Transient and harmonic analysis, flicker and unbalance
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 5 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
 Graphical LCD for measurements and recording status 
 Power directly from A phase - external power not required 
 Double insulated and fused voltage cables 
 Auto-scaling current transformer connection 
 Data download and firmware upgrade via USB 
 CAT IV 600V safety rating (PM45) and certified to IEC 61010 
 AS60529-2004 IP66 (PM45) and IP65 (PM35) protection 
 Wide operating temperature range: -20°C to 70°C 
 Wireless remote communications option available 
1.1.3 Current Sensor Options 
Refer to sections 4.1 and 4.2. 
1.1.4 Specifications 
PARAMETER 
PM45 
PARAMETER 
PM45 
Measurement 
General 
Samples per cycle 
204 @ 50Hz; 170@ 60Hz 
Input Cannels 
4 isolated voltage channels; 4 current channels 
Sample Rate 
PPL Synchronised (IEC 61000-4-7). 
Measurement Range 
A, B & c channels: 0- 600VAC; Vgnd 0 - 60 VAC (±1% reading ±1 lsd); 0- 3000A 
Memory 
15MB internal flash 
Input Range 
Voltage: 0-600VAC (660VAC absolute); 
Current: 0-440mV at 10k Ohms 
Power Meter 
V, A, Min, Max, Freq,TPF, DPF, KW, KVA, KVAR 
Instrument Accuracy 
0.4% readings + 1 lsd (current and voltage) 
Total Harmonic Distortion 
IEC 61000-4-7 (THD-F & THD-R) 
System Accuracy 
Voltage: 0.4% readings + 1 lsd; Current: 1% readings + 1 lsd 
Harmonics 
IEC 61000-4-7 (up to 48th Magnitude and Angle) 
Resolution Logged Data 
0.001V; 0.001A 
Interharmonics 
IEC 61000-4-7 (up to 48th) 
Resolution LCD 
0.1V; 0.1A 
Flicker (Pst & Plt) 
IEC 61000-4-15 (10min. Pst & 2hr. Plt) 
Voltage and Current Unbalance 
IEC 61000-4-30 
Circuit connections 
Three Phase Wye/Delta, Open/2-Element Delta, Split 
Phase & Single Phase 
Instrument Type 
Class B (IEC 61000-4-30) 
Current Probe Options 
C10* (0-10A), C100S* (10- 125A), C500* (25-600A), 
Flexi F3000-6 (150-3600A) * Not CATIV-600V Rated 
Frequency Range 
50Hz nom. (42.5-57.5) Hz 
60Hz nom. (51.0-69.0) Hz 
Communications 
Direct Connection: 
USB Serial Cable; Remote Connection: Cellular (GPRS/3G/CDMA) 
High Speed Event Recording 
User defined Rolling and/or Threshold Voltage and Current & Transient Triggers 
Mechanical & Power 
Table Capture (Sags/Swells) 
Half Cycle, Min/Max & Duration 
Power Source - Main 
60-600VAC from Phase A, and USB powered for
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 6 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
configuration and downloading 
RMS Snapshot 
Half Cycle, 5s - 30s duration 
Power Source - backup 
Non-rechargeable batteries 
Waveform Snapshot 
Sample rate for 400ms duration 
Power Consumption 
10W typical (from Phase A) 
Display 
Graphic LCD 128 x 64 bits (0.1 resolution) 
Environmental & Safety 
Real-Time-Clock 
3V 950mAh Li-Magnanese Dioxide/Organic Electrolyte 
Temperature Range 
-20°C (-4°F) to +60°C (+130°F) 
Dimensions 
230mm/9.1” (l) x 120mm/4.72” (w) x 90mm/3.6” (d) 
Humidity 
20%-99% Relative Humidity 
Weight 
7lbs (3kg) instrument only 
Protection Class 
IP66 (all weather housing) 
Protection levels 
IEC 61010-1 2001; Pollution degree 3; Measurement Category IV - 600V 
PM35 specifications are similar to the above with the following changes: 
 Protection Class: IP65; 
 Voltage lead connector is CAT III 600V; 
 No inter-harmonics.
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 7 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
1.2 SUIN SA2100 
1.2.1 Introduction 
The SUIN SA2100 is a comprehensive and cost effective instrument ideally suited for the electrical trades toolbox and intended to monitor your electrical supply and diagnose Power Quality issues on-site and in real-time. It is battery operated and therefore offers the flexibility of a handheld multi-meter. 
1.2.2 Key Features 
 Safety: CAT III 1000V / CAT IV 600V 
 Standards: IEC61000-4-30 (2008) S class EN50160 (2007) 
 Single-phase 2 W / Single-phase 3 W / 3-phase 3 W / 3-phase 4 W 
 Monitors four (4) voltages and currents 
 Display: Run Chart, Bar Chart, Vector Graphic, Waveform, Event List, Readings 
 Harmonics and interharmonics, flicker, transient capture, three-phase unbalance (voltage and current), dips and swells, voltage rapid change, and interruption 
 LAN interface PC can keep real-time remote communication 
 Built-in 8G memory card, USB port, LAN port for real-time remote control functionality and data download 
1.2.3 Current Sensor Options 
Description Part Number 5A Clamp-On CT SUC8C-5A 50A Clamp-On CT SUCTC0080 100A Clamp-On CT SUCTC0130 1000A Clamp-On CT SUCTC1535 3000A Flexible Rogowski Coil SUJK-3000A
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 8 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
SUC8C-5A SUCTC0080 SUCTC0130 
SUCTC1535 SUJK-3000A
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 9 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
1.2.4 Voltage Leads
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 10 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
1.2.5 Flexible Current Probe 
1.2.6 Carry Bag 
1.2.7 Kit Items 
Description Part Number Quantity SA2100 Power Quality Analyser SU2100PQA 1 Program Software for PC (CD) SU2100CD 1 2m voltage cable with 4mm banana plug SU2100VL 5 Alligator Clips SU2100CC 5 External DC Power Adaptor SU2100PA 1 External DC Adaptor SU2100PC 1 Carry Bag SU2100BAG 1 Hang Strap SU2100HS 1 Current Sensors 4 (select option)
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 11 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
1.2.8 Specifications 
Measurement Range 
Resolution 
Accuracy 
Voltage/Current/Frequency 
Channel 
3-phase line input + 1 neutral line input 
Vrms(dc+ac) 
1 ~ 1000Vrms 
0.1Vrms 
±5% 
Vpk 
1 ~ 1400Vpk 
0.1Vpk 
±5% 
V(CF) 
1.0 ~ >2.8 
0.01 
±5% 
Arms 
1~ 3000A 
1A 
±1% ± 5digits 
1~ 300A 
0.1A 
±1% ± 5digits 
Apk 
1 ~ 4000Apk 
1A 
±1% ± 5digits 
A(CF) 
1 ~ 10 
0.01 
±5% 
Frequency 
42.5~57.5Hz(50Hz nominal) 
0.01Hz 
±0.01% 
51~69Hz(60Hz nominal) 
0.01Hz 
±0.01% 
Dips & Swells 
Vrms1/2 
0 ~ 200% of nominal voltage 
0.1Vrms 
±1% 
Arms1/2 
1 ~ 3000A 
1A 
±1% ±5 counts 
1 ~ 300A 
0.1A 
±1% ±5 counts 
Threshold levels 
Programmable thresholds in percent of nominal voltage Event detection based upon ½ cycle rms voltages Captures Dips, Swells Interruptions and Rapid Voltage Changes 
Duration 
hhh,mm,ss,mmm 
0.5 cycle 
1 cycle 
Harmonic 
Harmonic Order 
1 ~ 50 
Inter-Harmonic Order 
1 ~ 49 
Voltage 
0.0 ~ 100.0% 
0.1% 
±0.1% ± nx0.1% 
Current 
0.0 ~ 100.0% 
0.1% 
±0.1% ± nx0.1% 
THD 
0.0 ~ 100.0% 
0.1% 
±2.5% 
DC Relative 
0.0 ~ 100.0% 
0.1% 
±2% 
Frequency 
0 ~ 3500Hz 
1Hz 
1Hz 
Phase 
-360° ~ 0° 
1° 
± nx1.5° 
Power And Energy 
Active Power/Apparent Power/Reactive Power 
1.0 ~ 20.00MW 
0.1kW 
±1.5±10 counts 
Energy 
0.00kWh ~ 200GWh 
10Wh 
±1.5±10 counts 
Power Factor 
0 ~ 1 
0.01 
±0.03 
Flicker 
Pst(1min),Pst,Plt,PF5 
0.00 ~ 20.00 
0.01 
±5% 
Unbalance 
Voltage 
0.0 ~ 5.0% 
0.1% 
±0.5% 
Current 
0.0 ~ 20.0% 
0.1% 
±1% 
Voltage Phase Angle 
-360° ~ 0° 
1° 
±2digits 
Current Phase Angle 
-360° ~ 0° 
1° 
±5digits 
Voltage Transient 
Vpk 
±6000Vpk 
1V 
±15% 
Vrms 
10 ~ 1000Vrms 
1V 
±2.5% 
Min. Tested Time 
50us
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 12 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
Sampling Rate 
20kS/s 
Inrush Current 
Arms(AC+DC) 
0~3000Arms 
0.1 
±1% ± 5digits 
Inrush Duration 
6s ~ 32min selectable 
10ms 
±20ms 
Logger 
Recording 
Parameter, duration time and time interval can be set by user, which can be export on PC 
Memory 
8G 
Max. recording time 
1 year 
System Monitor 
Parameters 
Vrms,Arms,Harmonic Volts,THD Volts,Plt,Vrms1/2,Arms1/2,Vneg,Hz,dips and swells, unbalance 
Record Time 
2h ~ 7days 
Record Event Number 
>10000 
Limits 
According EN50160 or customer definable 
General Characteristics 
Power 
AC220V(1±10%), 50Hz(1±5%), ≤10VA 
Interface 
USB_HOST, LAN 
Display 
5.6' TFT LCD, 320*240 
Battery 
7.4V, 4.4Ah, > 7 hours working time 
Dimension & Weight 262×173×66mm, 1.6kg
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 13 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
1.3 ZES Zimmer LMG500 
1.3.1 Introduction 
The ZES Zimmer LMG500 is a 1 to 8 Channel Precision Power Analyser. 
The LMG500 is best-in-class for measurements of: 
 Devices, e.g. E-machines, frequency inverters, and transformers; 
 Installations and associated elements; 
 Power grids and consumer electrical networks to determine interactions; and 
 Components, e.g. ferrite cores, semiconductors, and capacitors. 
Other applications include: 
 CE compliance tests on devices; 
 Analysing the feedback of harmonics and flicker (load variations); and 
 Standby power consumption. 
1.3.2 Key Features 
The most important features of the LMG500 are: 
 Wide dynamic measuring range from 3V to 1000V/3200Vpeak, 20mA to 32A/120A peak in direct measurement only by a single pair of sockets for each voltage and current input; 
 Modular with 1 to 8 power measuring channels; 
 Measuring accuracy at 45 to 65Hz 0.015% of reading plus 0.01% of range; 
 3MSample/s per channel, absolutely gapless sampling with the evaluation of all sampling values;
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 14 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
 Capturing transients and fast signal changes by event triggering in parallel to the ongoing measurement; 
 Group delay between voltage and current measuring input <3ns as standard to ascertain very precise measurements at low cosj and / or high frequencies; 
 Harmonics and interharmonics up to 50kHz internally, and up to 1MHz with an external PC; 
 Flicker, interactions between network and load; 
 Ergonomic user interface for easy, intuitive use of the power analyser; 
 Real-time evaluation of the measurements in numeric tables and diagrams; and 
 Data communication interfaces with high transfer rates (RS232, USB, IEEE488.2, Ethernet). 
1.3.3 Device Interface
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 15 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
1.3.4 Connections
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 16 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
2 Logging Instruments 
2.1 Load Logger 
2.1.1 Introduction 
Load Logger measures AC current (load) and is ideal for monitoring loads on circuits and switchboards to record load profiles that can be used to identify slow changing events such as long duration interruptions, outages and derive estimates of usage patterns. 
Load Logger is also useful as a diagnostic tool to assess load sharing and load balancing on single and three phase systems. 
Some common monitoring applications include: ac motors and pumps for pool, irrigation, lighting, data centres, air conditioning equipment and switchboards. 
2.1.2 Specifications 
PARAMETER 
MULTI-CHANNEL 
Input Channels 
Current Inputs (RMS) 
Scalable up to 4 channels - Phases A, B, C and Neutral 
Temperature Inputs (optional) 
2 x PT1000 RTD 
Communications 
Serial Data (standard) 
RS232 (115.2 kbps) 
Wireless (optional) 
Bluetooth 
Logging 
Logged Data Memory 
MicroSD 
Logging Interval 
Programmable from 1 minute 
Measurements 
Current (RMS), Max. Current (RMS), Current Unbalance,
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 17 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
Temperature 
Accuracy 
±0.5% (excludes current sensor) 
System Accuracy 
±1% (clamp-on current sensor) 
Outputs 
Visual Tools 
Graphical Interface 
Data File 
CSV format 
Visual Indicator 
2 x Status LED 
Digital 
2 x Latched Relays (optional) 
General 
Display (optional) 
LCD: Measurements and Max. Current time 
Current Sensors 
Flexible current or clamp-on current probes - Automatic detection 
Power Supply 
Non-rechargeable battery with External DC option 
Battery Life 
1 year (@ 5min. non-aggregated logging 
Safety Category 
IEC 61010-1,CAT IV 600V defined by CT 
Physical 
Dimensions (H x W x L) 
55 x 90 x 115 mm 
Weight 
390g (battery included) 
Material and Colour 
Polycarbonate, moulded in light grey 
Operating Temperature 
-20°C to 85°C 
Degree of Protection 
IP65, NEMA 4 
2.1.3 Installation 
The logger can be installed using a mix of clamp-on current and flexible current probes and automatically detects each sensor type. 
2.1.4 Software 
Configuration software included. 
2.1.5 Calibration 
Each Load Logger is factory calibrated. The calibration values are saved in the initial configuration file.
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 18 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
3 Remote (Online) Monitoring Systems 
3.1 Load Remote 
Load Remote is a Remote Terminal Unit (RTU) that measures AC current in up to five (5) circuits and facilitates on-line monitoring. All data is transmitted back to a secure database utilising modern communication networks with programmable intervals. The user is provided with a web login and password and able to quickly retrieve, view and download data on-line. 
HARDWARE INSTALLATION
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 19 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
Load Remote is also useful as a diagnostic tool to assess load sharing and load balancing on single and three phase systems. Load Remote is intended for applications requiring long term monitoring and where periodic site visits may not be feasible or access is difficult. 
Some common monitoring applications include: ac motors and pumps for pool, irrigation, lighting, data centres, air conditioning equipment and switchboards. 
Digital inputs/outputs and alarm thresholds available for control and condition monitoring applications. This product can be customised to your specific requirements. 
PARAMETER 
SPECIFICATION 
General electrical 
Rated load current 
Up to 3000A. 
Working voltage 
600V as defined by current sensor. 
Power source 
External 12V DC. 
Channels 
AC current (1) 
AC current, up to five (5) channels or circuits. 
Temperature (2) 
Optional: Temperature inputs. Combinations of (1) and (2) totalling five channels. 
Communications 
Remote communications 
Tri-Band UMTS (850MHz/900MHz/2100MHz); Dual-Band GSM/GPRS (900MHz/1800MHz). 
Device communications 
RS-232 for programming 
Data Pitching 
Programmable transmit interval 
1 minute minimum 
Physical 
Dimensions (H x W x D) 
171 x 121 x 55 mm 
Material 
Polycarbonate, moulded in light grey 
Rating 
IP65, NEMA4 
Operating temperature 
-20°C to 70°C 
Load Remote can be packaged into a suitable enclosure to meet your requirements and with various current probes. 
3.2 Monitoring Back-Up Generators 
OmniMetrix is a leader and pioneer in wireless remote monitoring, control and diagnostics for emergency power generator systems. With over 15 years of experience and thousands of monitored generators, OmniMetrix is the proven solution for making emergency power systems more reliable. The OmniMetrix system is currently installed globally on a wide range of critical facilities, including cell towers, grocery stores, medical facilities, data centers and public transportation systems, as well as federal, state and municipal government facilities. 
As a system that facility maintenance teams have described as vital, we get better information to the right people faster. 
OmniMetrix’s robust M2M (machine to machine) 24/7 monitoring system increases the reliability of your generators by eliminating 95% of all Fail-to-Start situations. Cost-effective monitors connect to all major brands of generators and are Modbus compatible.
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 20 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
3.2.1 G8500 SINGLE GENERATOR SYSTEM
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 21 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
3.2.2 G8600 MULTIPLE GENERATOR SYSTEM
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 22 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
3.2.3 G8700 MOBILE GENERATOR SYSTEM
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 23 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
3.2.4 G8800 RESIDENTIAL GENERATOR SYSTEM
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 24 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
4 Current Probes and Sensors 
4.1 Flexible Current Sensors 
PARAMETER 
1AFF3000-6 (3000A) (use with PM35) 
SAF3000_6B (3000A) (use with PM45) 
Electrical 
Rated Input Current 
3000A 
3000A 
Calibrated Output @ 1000A 50Hz 
78mV 
78mV 
Load resistance 
4.5KΩ 
4.5KΩ 
Bandwidth 
10Hz to 20kHz 
10Hz to 20kHz 
Accuracy (@ 25°C, 50Hz) 
± 0.5% of reading 
± 0.5% of reading 
Linearity (10% to 90% of range 
± 0.2% of reading 
± 0.2% of reading 
Phase Error (45Hz - 65Hz) 
± 1° 
± 1° 
Position Sensitivity 
± 2% of reading 
± 2% of reading 
Temperature Coefficient 
± 0.05% of reading / °C 
± 0.05% of reading / °C 
External Field (with cable >100mm from the head) 
± 0.25% of range 
± 0.25% of range 
Working Voltage 
1000V AC or DC 
1000V AC or DC 
General 
Probe and Cable Material 
Alcryn 2070 NC double insulated, UL94 V-0 
Alcryn 2070 NC double insulated, UL94 V-0 
Coupling Material 
Ultramid A3U Q720, UL94 V-0 
Ultramid A3U Q720, UL94 V-0 
Probe Cable Diameter 
9.9mm (nominal) 
9.9mm (nominal) 
Probe Cable Length 
610mm 
610mm 
Probe Cable Conductor Diameter 
194mm 
194mm 
Output Cable Length 
2m, terminated with Brad Harrison 8A4000-315 
2m UL.M12 4P F ST 2M PUR- 0.34 
Operating Temperature Range 
-20°C to +65°C 
-20°C to +65°C 
Storage Temperature Range 
-40°C to +75°C 
-40°C to +75°C 
Operating Humidity 
15% to 85% (non-condensing) 
15% to 85% (non-condensing) 
Degree of Protection 
IP65 
IP65 
Colour 
Probe: Green RAL6018 
Probe: Green RAL6018
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 25 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
PARAMETER 
1ACF3000-6 (3000A) (use with PM35) 
1AF3000-6 (3000A) (use with PM45) 
Electrical 
Maximum Measureable Current 
100kA at (50/60)Hz 
100kA at (50/60)Hz 
Internal Resistance 
30Ω per 400mm 
30Ω per 400mm 
Accuracy 
± 1% (Calibrated) 
± 1% (Calibrated) 
Linearity 
± 0.2% (Calibrated) 
± 0.2% (Calibrated) 
Output Signal (Sinusoidal) 
100mV/KA @ 50Hz 
100mV/KA @ 50Hz 
Frequency Range 
20Hz to 5kHz 
20Hz to 5kHz 
Position Sensitivity 
± 2% maximum 
± 2% maximum 
Influence of External Field 
± 2% maximum 
± 2% maximum 
Temperature Coefficient 
± 0.07% per °C 
± 0.07% per °C 
Working Voltage (max.) 
1000V at (50/60)Hz 
1000V at (50/60)Hz 
Safety Category (IEC 61010-1) 
1000V CAT III / 600V CATIV 
1000V CAT III / 600V CATIV 
High Voltage Withstand 
7400VAC (50/60)Hz for 1 minute 
7400VAC (50/60)Hz for 1 minute 
Dimensions 
Cable length 
2m 
2m 
Coil Inside Diameter A 
170mm 
170mm 
Coil Outside Diameter B 
201mm 
201mm 
Coil Length C 
600mm 
600mm 
Cap Coupling cross section D 
18mm (min.) 
18mm (min.) 
Cap Coupling cross section E 
23mm (max.) 
23mm (max.) 
Coil cross-section F 
15.5mm 
15.5mm 
Materials 
Transducer and cable 
Thermoplastic RUBBER, flame retardant UL 94 V-O rated 
Thermoplastic RUBBER, flame retardant UL 94 V-O rated 
Couplings 
Polypropylene UL 94 V-O rated 
Polypropylene UL 94 V-O rated 
Colour (transducer) 
Blue 
Blue 
Colour (Cable and couplings) 
Black 
Black 
Cable 
1000V UL Style 20940; Diameter: 5.5mm - wires 2 x 24AWG 
1000V UL Style 20940; Diameter: 5.5mm - wires 2 x 24AWG 
Shield 
85% coil, 100% output cable 
85% coil, 100% output cable 
Environmental 
Working Temperature 
-20°C to +70°C 
-20°C to +70°C 
Relative Humidity 
85% (non-condensing) 
85% (non-condensing) 
Pollution Degree 
2 
2 
Maximum Altitude 
2000m 
2000m
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 26 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
4.2 Clamp on Current Sensors 
PARAMETER 
1AC10 (10A) 
(use with PM45) 
1ACR100S (100A) (use with PM35) 
1AC100S (100A) (use with PM45) 
General electrical 
Rated Input Current 
10A. 
100A. 
100A. 
Maximum Input Current 
15A. 
150A. 
150A. 
Output Signal 
440mV @ 10A. 
440mV @ 100A. 
440mV @ 100A. 
Burden 
Included 
2.2 Ω (external) 
Included 
Accuracy 
±1.0% 
±1.0% 
±1.0% 
Frequency Range 
45Hz - 5000Hz 
45Hz - 5000Hz 
45Hz - 5000Hz 
Dielectric Strength 
3000V @ 60Hz for 1 minute 
3000V @ 60Hz for 1 minute 
3000V @ 60Hz for 1 minute 
Working Voltage 
Bare conductor: 30V; Insulated conductor: 600V 
Bare conductor: 30V; Insulated conductor: 600V 
Bare conductor: 30V; Insulated conductor: 600V 
Physical 
Dimensions (H x W x L) 
(90.5 x 41.2 x 23.8) mm 
(90.5 x 41.2 x 23.8) mm 
(90.5 x 41.2 x 23.8) mm 
Jaw Aperture 
(14.3 x 15.9) mm 
(14.3 x 15.9) mm 
(14.3 x 15.9) mm 
Weight 
113 grams (excluding lead and connector) 
113 grams (excluding lead and connector) 
113 grams (excluding lead and connector) 
Colour 
Grey / light grey 
Grey / light grey 
Grey / light grey 
Safety Class 
Class III per IEC 61010- 1 
Class III per IEC 61010- 1 
Class III per IEC 61010- 1 
Operating temperature 
-20°C to 50°C 
-20°C to 50°C 
-20°C to 50°C 
Relative Humidity 
85% (non-condensing) 
85% (non-condensing) 
85% (non-condensing)
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 27 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
PARAMETER 
1ACR100 (100A) (use with PM35) 
1ACR500 (500A) (use with PM35) 
1ASC500 (500A) (use with PM45) 
General electrical 
Rated Input Current 
100A 
500A 
500A 
Maximum Input Current 
120A 
650A 
650A 
Output Signal 
440mV @ 100A. 
440mV @ 500A. 
440mV @ 500A. 
Burden 
Included 
Included 
Included 
Accuracy (Ratio Error) 
Better than ±1.0% 
Maximum Error (Ratio Error) 
1% accuracy from 20% to 125% of rated current 
1.5% @ 5% and 0.5% @110% of rated current 
1.5% @ 5% and 0.5% @110% of rated current 
Phase Error 
<0.36 degrees at rated current 
Maximum Burden 
15VA 
15VA 
15VA 
Accuracy Class 
0.5M AS1675 
0.5M AS1675 
0.5M AS1675 
Double Insulation 
300V AC RMS 
300V AC RMS 
300V AC RMS 
Frequency Range 
40Hz - 5000Hz 
5Hz - 5000Hz; 0.5% R.E. (40-85) Hz 
5Hz - 5000Hz; 0.5% R.E. (40-85) Hz 
Dielectric Strength 
3000V @ 60Hz for 1 minute 
3000V @ 60Hz for 1 minute 
3000V @ 60Hz for 1 minute 
Working Voltage 
650V 
650V 
650V 
Physical 
Dimensions (H x W x L) 
(99 x 210 x 60) mm 
(99 x 210 x 60) mm 
(99 x 210 x 60) mm 
Jaw Aperture 
52 mm 
52mm 
52mm 
Weight 
750 grams (excluding lead and connector) 
750 grams (excluding lead and connector) 
750 grams (excluding lead and connector) 
Encapsulation / Colour 
Fully insulated / Black 
Fully insulated / Black 
Fully insulated / Black 
Safety Class 
CAT III per IEC 61010- 1 
CAT III per IEC 61010- 1 
CAT IV per IEC 61010-1 
Operating temperature 
-10°C to 50°C 
-10°C to 50°C 
-10°C to 50°C
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 28 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
4.3 Miniature Split-Core Current Transformers 
4.3.1 Key Features and General Specifications 
 Lightweight, safe (includes internal burden), 
quick and easy installation - no power line 
disruption required. 
 Rated primary current: up to 400Aac 
 Rated secondary: 0.333Vac at rated primary 
Current 
 Class (accuracy): 0.5, 1.0, 3.0 [IEC 60044-1] 
 Rated security coefficient: FS<5 
 Case material: Nylon resin UL flame retardant 
Rating 94-VO 
 Highest voltage for equipment Um (rms): 720Vac 
 Rated power-frequency withstand voltage (rms): 
3000Vac 
 Frequency range: (50/60) Hz 
 Operating temperature: 15 to 60 
 RoHS compliant 
 CE approved 
 ETL approved, CAT II 600V 
 Leads: 0.8 Foot (240mm), UL 1015, twisted pair, 
0.34m2 (22AWG) 
4.3.2 Range 
Description Part Number Input: 1-25A;Output: 0.333V@ 25A; Class: 1.0; Cable diameter: 10.2mm CTSA010 Input: 5-100A;Output: 0.333V@ 100A; Class: 0.5; Cable diameter: 16.2mm CTSA016 Input: 5-200A;Output: 0.333V@ 200A; Class: 0.5; Cable diameter: 24.2mm CTSA024 Input: 5-400A;Output: 0.333V@ 400A; Class: 0.5; Cable diameter: 35.2mm CTSA035
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 29 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
4.4 Substation Current Transformer Converters 
4.4.1 Introduction 
CK1: 1 Amp Substation CT Converter CK5: 5 Amp Substation CT Converter 
The CK1 or CK5 Powermonic Current Transformer (CT) Converter is a three phase device that transforms the standard 1A or 5A secondary current from a CT to a 200 mA output current suitable for direct connection to a Powermonic CT input. 
Internal protection is provided to enable the output leads to be disconnected from the Powermonic without affecting the CT secondary circuits. 
The units are designed for high accuracy and therefore lend themselves for Metering and Power Quality applications. 
4.4.2 Specifications 
PARAMETER 
CK1 (1A to 200mA) 
CK5 (5A to 200mA) 
Electrical 
Rated Input Current 
1A 
5A 
Rated Output Current 
200mA 
200mA 
Accuracy Class 
0.5M (AS1675) 
0.5M (AS1675) 
Working Voltage 
1000V AC or DC 
1000V AC or DC 
General 
Input Connections 
Red, White and Blue banana sockets 
Red, White and Blue banana sockets 
Output Connections 
Colour coded 1.8m leads with 4 pin connectors to suite PM20, PM30, PM30+, PM40 
Colour coded 1.8m leads with 4 pin connectors to suite PM20, PM30, PM30+, PM40 
Enclosure 
Light grey polycarbonate 
Light grey polycarbonate 
Weight 
4.4kg 
4.4kg 
Dimensions (W x L x D) 
(140 x 230 x 100) mm 
(140 x 230 x 100) mm 
Including glands and sockets 
(140 x 280 x 100) mm 
(140 x 280 x 100) mm
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 30 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
5 Instrument Current Transformers 
Australian Standard 60044.1-2007 Instrument transformers Part 1: Current transformers (IEC 60044-1 Ed.1.2 (2003) MOD).
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 31 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
5.1 Metering 
5.1.1 Measuring - PVC 
The SES range of PVC tape insulated metering CTs are designed and manufactured to cater for wide range of applications. They are tested to IEC 60044-1 2003-02 and are certified to ASTA and CE mark Certified to UL. The standard rated secondary current is 5A. 
Ratio 
Class 3 5VA 
Class 1 15VA 
Class 0.5 15VA 
ID 
OD 
HT 
ID 
OD 
HT 
ID 
OD 
HT 
60/5 A 
28 
70 
28 
28 
70 
102 
100/5 A 
34 
74 
23 
34 
80 
72 
34 
80 
185 
150/5 A 
34 
74 
23 
34 
80 
48 
34 
100 
72 
200/5 A 
45 
80 
28 
34 
80 
33 
34 
80 
92 
250/5 A 
45 
80 
28 
45 
80 
38 
45 
80 
70 
300/5 A 
45 
80 
28 
45 
80 
38 
45 
80 
60 
400/5 A 
60 
96 
23 
60 
96 
23 
60 
96 
40 
500/5 A 
65 
100 
23 
68 
100 
23 
65 
100 
30 
600/5 A 
65 
100 
23 
68 
100 
23 
85 
100 
30 
800/5 A 
85 
122 
23 
85 
122 
28 
85 
122 
40 
1000/5 A 
85 
122 
23 
85 
122 
28 
90 
122 
30 
1200/5 A 
90 
135 
23 
90 
135 
28 
90 
135 
33 
1600/5 A 
90 
135 
23 
90 
135 
28 
122 
135 
33 
2000/5 A 
123 
162 
23 
123 
162 
23 
122 
165 
33 
2500/5 A 
123 
162 
23 
123 
162 
23 
122 
165 
35 
3000/5 A 
123 
162 
23 
123 
162 
23 
140 
165 
35 
3500/5 A 
143 
185 
28 
143 
185 
28 
140 
190 
30 
4000/5 A 
143 
185 
28 
143 
185 
28 
140 
190 
30 
5000/5 A 
143 
185 
28 
143 
185 
28 
140 
190 
35
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 32 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
5.1.2 Measuring - MBQ Series 
MBQ series current transformers are ideally designed for bus bar mounting and find applications in measurement, test and control of electrical equipment. The MBQ current transformer is housed into a case of PPO flame retardant material. 
Type 
A 
B 
C 
D 
MBQ 60/30 
75 
60 
30 
30 x 10 
MBQ 60/40 
75 
60 
30 
40 x 10 
MBQ 95/50 
105 
95 
40 
60 x 30 
MBQ 95/70 
105 
95 
40 
60 x 10 
MBQ 130/100 
167 
129 
60 
100 x 55 
Type 
MBQ 60/30 
MBQ 60/40 
MBQ 95/50 
MBQ 95/70 
MBQ 130/100 
Ratio 
Burden (VA) 
Burden (VA) 
Burden (VA) 
Burden (VA) 
Burden (VA) 
Class 1 
Class 0.5 
Class 1 
Class 0.5 
Class 1 
Class 0.5 
Class 1 
Class 0.5 
Class 1 
Class 0.5 
100/5 A 
2.5 
1.5 
125/5 A 
2.5 
1.5 
150/5 A 
2.5 
2.5 
2.5 
1.5 
200/5 A 
5 
5 
2.5 
1.5 
2.5 
1.5 
250/5 A 
5 
5 
5 
2.5 
2.5 
1.5 
300/5 A 
5 
5 
5 
2.5 
2.5 
1.5 
5 
2.5 
400/5 A 
5 
5 
5 
2.5 
5 
2.5 
10 
5 
500/5 A 
10 
5 
5 
2.5 
10 
5 
15 
10 
600/5 A 
10 
5 
10 
5 
10 
5 
15 
10 
5 
2.5 
750/5 A 
10 
5 
10 
5 
15 
10 
10 
5 
800/5 A 
10 
5 
10 
5 
15 
10 
10 
5 
1000/5 A 
15 
10 
15 
15 
15 
10 
1200/5 A 
15 
10 
15 
15 
15 
10 
1250/5 A 
15 
10 
15 
15 
15 
10 
1500/5 A 
15 
15 
15 
15 
15 
15 
1600/5 A 
15 
15 
15 
15 
15 
15 
2000/5 A 
15 
15 
15 
15 
2500/5 A 
15 
15 
3000/5 A 
15 
15
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 33 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
5.1.3 Measuring - MSQ Series 
MSQ series current transformers are ideally designed for bus bar mounting and find applications in measurement, test and control of electrical equipment. The MSQ current transformer is housed into a case of PPO flame retardant material. 
FEATURES: 
 Flame retardant 
 High mechanical strength 
 High dielectric strength 
 Transparent sealable terminal cover 
 Base or Bus bar mounting 
Type 
A 
B 
C 
D 
MSQ 30 
98 
75 
43 
30 x 10 
MSQ 40 
98 
75 
43 
40 x 10 
MSQ 60 
127 
101 
44 
60 x 20 
MSQ 85 
164 
128 
42 
80 x 30 
MSQ 100 
156 
144 
44 
100 x 10 
MSQ 125 
220 
190 
42 
125 x 58
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 34 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
TypeClass 1Class 0.5Class 1Class 0.5Class 1Class 0.5Class 1Class 0.5Class 1Class 0.5Class 1Class 0.5100/5 A52.51.51.5125/5 A52.51.51.5150/5 A552.51.5200/5 A10552.5250/5 A101052.52.51.5300/5 A151052.552.5400/5 A15151051057.55500/5 A15151051057.55600/5 A151515101051057.55750/5 A15101051057.55800/5 A151015101051051000/5 A1510151015101051200/5 A15151510151015101250/5 A15151510151015101500/5 A15151515151515151600/5 A15151515151515152000/5 A1515151515152500/5 A151515153000/5 A151515154000/5 A15155000/5 A15156000/5 A1515Burden (VA) MSQ 125Burden (VA) MSQ 30MSQ 40MSQ 60MSQ 85MSQ 100RatioBurden (VA)Burden (VA)Burden (VA)Burden (VA)
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 35 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
5.1.4 Measuring - Tape Insulated Ring Type - KTM Series 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KTM1R30PD 
30/5 A 
2.5 
5 
30 
75 
70 
KTM1R40PD 
40/5 A 
2.5 
5 
30 
75 
55 
KTM1R50PD 
50/5 A 
2.5 
5 
30 
75 
45 
KTM1R50QD 
50/5 A 
5 
5 
30 
75 
75 
KTM1R75PD 
75/5 A 
2.5 
5 
30 
75 
35 
KTM1R75QD 
75/5 A 
5 
5 
30 
80 
60 
KTM1R100QB 
100/5 A 
5 
5 
30 
80 
70 
KTM1R100RB 
100/5 A 
7.5 
1 
30 
75 
90 
KTM1R125QB 
125/5 A 
5 
1 
30 
80 
60 
KTM1R125RB 
125/5 A 
7.5 
1 
30 
75 
65 
KTM1R150QB 
150/5 A 
5 
1 
30 
80 
40 
KTM1R150TB 
150/5 A 
7.5 
1 
30 
80 
80 
KTM1R150QA 
150/5 A 
15 
0.5 
30 
75 
75 
KTM1R200QB 
200/5 A 
5 
1 
30 
75 
30 
KTM1R200QA 
200/5 A 
5 
0.5 
30 
75 
45 
KTM1R200TB 
200/5 A 
15 
1 
30 
75 
55 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KTM2R100QB 
100/5 A 
5 
1 
45 
95 
100 
KTM2R125QB 
125/5 A 
5 
1 
45 
90 
55 
KTM2R150QB 
150/5 A 
5 
1 
45 
90 
45 
KTM2R150QA 
150/5 A 
5 
0.5 
45 
95 
90 
KTM2R200QB 
200/5 A 
5 
1 
45 
90 
30 
KTM2R200QA 
200/5 A 
5 
0.5 
45 
90 
60 
KTM2R200TB 
200/5 A 
15 
1 
45 
90 
60 
KTM2R250QB 
250/5 A 
5 
1 
45 
90 
30 
KTM2R250QA 
250/5 A 
5 
0.5 
45 
95 
40 
KTM2R250TB 
250/5 A 
15 
1 
45 
90 
50 
KTM2R300QB 
300/5 A 
5 
1 
45 
90 
25 
KTM2R300QA 
300/5 A 
5 
0.5 
45 
90 
30
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 36 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
KTM2R300TB 
300/5 A 
15 
1 
45 
90 
45 
KTM2R400QB 
400/5 A 
5 
1 
45 
90 
25 
KTM2R400QA 
400/5 A 
5 
0.5 
45 
90 
25 
KTM2R400TB 
400/5 A 
15 
1 
45 
90 
35 
KTM2R400TA 
400/5 A 
15 
0.5 
45 
90 
45 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KTM3R300QB 
300/5 A 
5 
1 
55 
95 
35 
KTM3R300QA 
300/5 A 
5 
0.5 
55 
95 
45 
KTM3R300TB 
300/5 A 
15 
1 
55 
100 
50 
KTM3R400QB 
400/5 A 
5 
1 
55 
100 
25 
KTM3R400QA 
400/5 A 
5 
0.5 
55 
105 
35 
KTM3R400TB 
400/5 A 
15 
1 
55 
100 
45 
KTM3R400TA 
400/5 A 
15 
0.5 
55 
120 
40 
KTM3R500QB 
500/5 A 
5 
1 
55 
100 
25 
KTM3R500QA 
500/5 A 
5 
0.5 
55 
105 
30 
KTM3R500TB/TA 
500/5 A 
15 
1/0.5 
55 
100 
40 
KTM3R600QB/QA 
600/5 A 
5 
1/0.5 
55 
105 
30 
KTM3R600TB/TA 
600/5 A 
15 
1/0.5 
55 
105 
40 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KTM4R600QB/QA 
600/5 A 
5 
1/0.5 
70 
120 
30 
KTM4R600TB/TA 
600/5 A 
15 
1/0.5 
70 
120 
40 
KTM4R800QB 
800/5 A 
5 
1 
70 
120 
30 
KTM4R800QA 
800/5 A 
5 
0.5 
70 
110 
30 
KTM4R800TB/TA 
800/5 A 
15 
1/0.5 
70 
120 
35 
KTM4R1000QB/QA 
1000/5 A 
5 
1/0.5 
70 
120 
30 
KTM4R1000TB/TA 
1000/5 A 
15 
1/0.5 
70 
120 
35 
KTM4R1200/QA/ 
1200/5 A 
5/15 
1/0.5 
70 
120 
30 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KTM5R800QB/QA 
800/5 A 
5 
1/0.5 
85 
125 
30 
KTM5R800TB/TA 
800/5 A 
15 
1/0.5 
85 
140 
35 
KTM5R1000QB/QA 
1000/5 A 
5 
1/0.5 
85 
125 
30 
KTM5R1000TB/TA 
1000/5 A 
15 
1/0.5 
85 
140 
30 
KTM5R1200QA 
1200/5 A 
5 
0.5 
85 
140 
30 
KTM5R1200TB/TA 
1200/5 A 
15 
1/0.5 
85 
140 
30 
KTM5R1600QB/QA/TB 
1600/5 A 
5/15 
1/0.5 
85 
140 
30 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KTM6R1000QB/QA 
1000/5 A 
5 
1/0.5 
115 
155 
30
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 37 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
KTM6R1000TB/TA 
1000/5 A 
15 
1/0.5 
115 
170 
35 
KTM6R1200QB/QA 
1200/5 A 
5 
1/0.5 
115 
155 
30 
KTM6R1200TB/TA 
1200/5 A 
15 
1/0.5 
115 
170 
30 
KTM6R1600QB/ 
1600/5 A 
5/15 
1/0.5 
115 
170 
30 
KTM6R2000TB/TA 
2000/5 A 
15 
1/0.5 
115 
170 
30 
KTM6R2500TB/TA 
2500/5 A 
15 
1/0.5 
115 
185 
35 
KTM6R3000TB/TA 
3000/5 A 
15 
1/0.5 
115 
185 
35 
KTM6R3500TB/TA 
3500/5 A 
15 
1/0.5 
115 
185 
35 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KTM7R3000TB/TA 
3000/5 A 
15 
1/0.5/0.2 
135 
205 
35 
KTM7R3500TB/TA 
3500/5 A 
15 
1/0.5/0.2 
135 
205 
35 
KTM7R4000TB/TA 
4000/5 A 
15 
1/0.5/0.2 
135 
205 
35 
KTM7R4500TB/TA 
4500/5 A 
15 
1/0.5/0.2 
135 
210 
40 
KTM7R5000TB/TA 
5000/5 A 
15 
1/0.5/0.2 
135 
210 
40 
KTM8R4000TB/TA 
4000/5 A 
15 
1/0.5/0.2 
170 
240 
35 
KTM8R4500TB/TA 
4500/5 A 
15 
1/0.5/0.2 
170 
240 
35 
KTM8R5000TB/TA 
5000/5 A 
15 
1/0.5/0.2 
170 
240 
35
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 38 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
5.1.5 Measuring - Resin Cast Ring Type - KRM Series 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KRM1R30PD 
30/5 A 
2.5 
5 
30 
80 
80 
KRM1R40PD 
40/5 A 
2.5 
5 
30 
95 
40 
KRM1R50PD 
50/5 A 
2.5 
5 
30 
75 
65 
KRM1R50QD 
50/5 A 
5 
5 
30 
80 
80 
KRM1R75PD 
75/5 A 
2.5 
5 
30 
95 
40 
KRM1R75QD 
75/5 A 
5 
5 
30 
75 
65 
KRM1R100QB 
100/5 A 
5 
1 
30 
80 
80 
KRM1R100RB 
100/5 A 
7.5 
1 
30 
90 
135 
KRM1R125QB 
125/5 A 
5 
1 
30 
75 
65 
KRM1R125RB 
125/5 A 
7.5 
1 
30 
80 
80 
KRM1R150QB 
150/5 A 
5 
1 
30 
75 
65 
KRM1R150QA 
150/5 A 
5 
0.5 
30 
80 
80 
KRM1R200QB 
200/5 A 
5 
1 
30 
75 
40 
KRM1R200QA 
200/5 A 
5 
0.5 
30 
75 
65 
KRM1R200TB 
200/5 A 
15 
1 
30 
80 
70 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KRM2R100QB 
100/5 A 
5 
1 
45 
100 
100 
KRM2R125QB 
125/5 A 
5 
1 
45 
98 
60 
KRM2R150QB 
150/5 A 
5 
1 
45 
100 
45 
KRM2R150QA 
150/5 A 
5 
0.5 
45 
100 
100 
KRM2R200QB 
200/5 A 
5 
1 
45 
95 
40 
KRM2R200QA 
200/5 A 
5 
0.5 
45 
98 
60 
KRM2R200TB 
200/5 A 
15 
1 
45 
98 
60 
KRM2R250QB 
250/5 A 
5 
1 
45 
95 
40 
KRM2R250QA 
250/5 A 
5 
0.5 
45 
95 
40 
KRM2R250TB 
250/5 A 
15 
1 
45 
100 
45 
KRM2R300QB 
300/5 A 
5 
1 
45 
95 
40 
KRM2R300QA 
300/5 A 
5 
0.5 
45 
95 
40 
KRM2R300TB 
300/5 A 
15 
1 
45 
100 
45
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 39 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
KRM2R400QB 
400/5 A 
5 
1 
45 
95 
40 
KRM2R400QA 
400/5 A 
5 
0.5 
45 
95 
40 
KRM2R400TB 
400/5 A 
15 
1 
45 
95 
40 
KRM2R400TA 
400/5 A 
15 
0.5 
45 
95 
40 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KRM3R300QB 
300/5 A 
5 
1 
55 
95 
40 
KRM3R300QA 
300/5 A 
5 
0.5 
55 
100 
45 
KRM3R400QB/QA 
400/5 A 
5 
1/0.5 
55 
95 
40 
KRM3R400TB 
400/5 A 
15 
1 
55 
98 
60 
KRM3R300QB 
300/5 A 
5 
1 
55 
95 
40 
KRM3R300QA 
300/5 A 
5 
0.5 
55 
100 
45 
KRM3R400QB/QA 
400/5 A 
5 
1/0.5 
55 
95 
40 
KRM3R400TB 
400/5 A 
15 
1 
55 
98 
60 
KRM3R400TA 
400/5 A 
15 
0.5 
55 
115 
35 
KRM3R500QB/QA 
500/5 A 
5/15 
1/0.5 
55 
95 
40 
KRM3R600QB/QA 
600/5 A 
5/15 
1/0.5 
55 
100 
45 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KRM4R600QB/QA 
600/5 A 
5 
1/0.5 
70 
115 
35 
KRM4R600TB 
600/5 A 
15 
1 
70 
115 
35 
KRM4R600TA 
600/5 A 
15 
0.5 
70 
140 
25 
KRM4R800QB/QA 
800/5 A 
5/15 
1/0.5 
70 
115 
35 
KRM4R1000QB/QA 
1000/5 A 
5 
1/0.5 
70 
115 
35 
KRM4R1000TB/TA 
1000/5 A 
15 
1/0.5 
70 
140 
25 
KRM4R1200QB/QA 
1200/5 A 
5/15 
1/0.5 
70 
115 
35 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KRM5R800QB/QA 
800/5 A 
5/15 
1/0.5 
85 
140 
25 
KRM5R1000QB/QA 
1000/5 A 
5/15 
1/0.5 
85 
140 
25 
KRM5R1200QB/QA 
1200/5 A 
5/15 
1/0.5 
85 
140 
25 
KRM5R1600QB/QA/ 
1600/5 A 
5/15 
1/0.5 
85 
145 
35 
KRM6R1000QB/QA 
1000/5 A 
5/15 
1/0.5 
115 
175 
30
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 40 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
5.1.6 Measuring - Resin Cast Ring Type - KSM Series 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KSM1R30PD 
30/5 A 
2.5 
5 
30 
85 
85 
KSM1R40PD 
40/5 A 
2.5 
5 
30 
90 
40 
KSM1R50QD 
50/5 A 
5 
5 
30 
85 
85 
KSM1R100QB 
100/5 A 
5 
1 
30 
85 
85 
KSM1R150QD 
150/5 A 
5 
5 
30 
90 
40 
KSM1R150TB 
150/5 A 
15 
1 
30 
85 
85 
KSM1R200QB 
200/5 A 
5 
1 
30 
90 
40 
KSM1R200TB 
200/5 A 
15 
1 
30 
80 
60 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KSM2R150QD 
150/5 A 
5 
5 
45 
90 
40 
KSM2R150QB 
150/5 A 
5 
1 
45 
100 
40 
KSM2R200QB 
200/5 A 
5 
1 
45 
90 
40 
KSM2R200TB 
200/5 A 
15 
1 
45 
100 
65 
KSM2R250QB 
250/5 A 
5 
1 
45 
90 
40 
KSM2R250TB 
250/5 A 
15 
1 
45 
100 
65 
KSM2R300QB 
300/5 A 
5 
1 
45 
90 
40 
KSM2R300TB 
300/5 A 
15 
1 
45 
100 
40 
KSM2R300SA 
300/5 A 
10 
0.5 
45 
100 
40 
KSM2R400QB 
400/5 A 
5 
1 
45 
90 
45 
KSM2R400TB 
400/5 A 
15 
1 
45 
100 
40 
KSM2R400SA 
400/5 A 
10 
0.5 
45 
90 
45
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 41 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KSM3R300TB 
300/5 A 
15 
1 
55 
100 
65 
KSM3R300SA 
300/5 A 
10 
0.5 
55 
100 
65 
KSM3R400TB 
400/5 A 
15 
1 
55 
120 
40 
KSM3R400SA 
400/5 A 
10 
0.5 
55 
100 
40 
KSM3R500TB 
500/5 A 
15 
1 
55 
100 
45 
KSM3R500SA 
500/5 A 
10 
0.5 
55 
100 
40 
KSM3R600TB 
600/5 A 
15 
1 
55 
100 
40 
KSM3R600SA 
600/5 A 
10 
0.5 
55 
100 
40 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KSM4R800TA 
800/5 A 
15 
0.5 
70 
120 
40 
KSM4R1000TA 
1000/5 A 
15 
0.5 
70 
120 
40 
KSM4R1200TA 
1200/5 A 
15 
0.5 
70 
120 
40 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KSM5R800TA 
800/5 A 
15 
0.5 
85 
145 
40 
KSM5R1000TA 
1000/5 A 
15 
0.5 
85 
145 
40 
KSM5R1200TA 
1200/5 A 
15 
0.5 
85 
145 
40 
KSM5R1200TE 
1200/5 A 
15 
0.2 
85 
145 
40 
KSM5R1600TE 
1600/5 A 
15 
0.2 
85 
145 
40 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KSM6R1000TA 
1000/5 A 
15 
0.5 
115 
175 
40 
KSM6R1000TE 
1000/5 A 
15 
0.2 
115 
175 
40 
KSM6R1200TA 
1200/5 A 
15 
0.5 
115 
175 
40 
KSM6R1200QE 
1200/5 A 
5 
0.2 
115 
175 
40 
KSM6R1200TE 
1200/5 A 
15 
0.2 
115 
175 
40 
KSM6R1600TA 
1600/5 A 
15 
0.5 
115 
175 
40 
KSM6R1600TE 
1600/5 A 
15 
0.2 
115 
175 
40 
KSM6R2000TA 
2000/5 A 
15 
0.5 
115 
175 
40 
KSM6R2000SE 
2000/5 A 
10 
0.2 
115 
175 
40 
KSM6R2000TE 
2000/5 A 
15 
0.2 
115 
175 
40 
KSM6R2500TE 
2500/5 A 
15 
0.2 
115 
175 
40 
KSM6R3000TE 
3000/5 A 
15 
0.2 
115 
175 
40 
KSM6R3500TE 
3500/5 A 
15 
0.2 
115 
175 
40
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 42 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
5.2 Protection 
5.2.1 Protection - PVC 
The SES range of PVC tape insulated Protection CTs are designed and manufactured to cater for wide range of applications. They are tested to IEC 60044-1 2003-02 and are certified to ASTA and CE mark Certified to UL. The standard rated secondary current is 5A. 
Ratio 
Class 10P5 15VA 
Class 10P10 15VA 
Class 5P10 15VA 
ID 
OD 
HT 
ID 
OD 
HT 
ID 
OD 
HT 
60/5 A 
34 
100 
148 
25 
150 
155 
25 
150 
165 
100/5 A 
34 
100 
98 
34 
100 
168 
34 
100 
180 
150/5 A 
34 
100 
68 
34 
100 
108 
34 
100 
130 
200/5 A 
34 
100 
68 
34 
100 
88 
34 
100 
110 
250/5 A 
45 
96 
78 
45 
96 
108 
45 
96 
110 
300/5 A 
45 
96 
68 
45 
96 
108 
45 
96 
120 
400/5 A 
60 
100 
68 
60 
100 
108 
45 
96 
100 
500/5 A 
60 
100 
58 
60 
100 
93 
60 
100 
110 
600/5 A 
65 
100 
58 
68 
110 
78 
68 
110 
88 
800/5 A 
85 
120 
48 
85 
120 
73 
85 
120 
88 
1000/5 A 
82 
123 
65 
82 
123 
80 
1200/5 A 
90 
135 
65 
90 
135 
80 
1600/5 A 
90 
135 
55 
90 
135 
70 
2000/5 A 
125 
178 
43 
125 
178 
43 
2500/5 A 
125 
178 
35 
125 
178 
35 
3000/5 A 
120 
178 
35 
120 
178 
35 
3500/5 A 
140 
200 
35 
140 
200 
35 
4000/5 A 
140 
200 
35 
140 
200 
35 
5000/5 A 
140 
200 
35 
140 
200 
35
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 43 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
5.2.2 Protection - Tape Insulated Ring Type - KTP Series 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
Part Number 
Class 
OD 
HT 
KTP1R100QL5 
100/5 A 
5 
10P5 
30 
80 
105 
KTP1R100QM10 
5P10 
95 
130 
KTP1R100RL5 
100/5 A 
7.5 
10P5 
30 
95 
100 
KTP1R100RM10 
5P10 
120 
115 
KTP1R100SL5 
100/5 A 
10 
10P5 
30 
95 
125 
KTP1R100SM10 
5P10 
120 
150 
KTP1R150QM5 
150/5 A 
5 
5P5 
30 
80 
75 
KTP1R150QM10 
5P10 
95 
95 
KTP1R150RL10 
150/5 A 
7.5 
10P10 
30 
95 
135 
KTP1R150RM10 
5P10 
95 
135 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
Part Number 
Class 
OD 
HT 
KRP2R100QL5 
100/5 A 
5 
10P5 
45 
100 
100 
KTP2R100QM10 
5P10 
110 
115 
KTP2R100SL5 
100/5 A 
10 
10P5 
45 
105 
125 
KTP2R100SM10 
5P10 
140 
135 
KTP2R150RL10 
150/5 A 
7.5 
10P10 
45 
110 
115 
KTP2R150RM10 
5P10 
110 
115 
KTP2R200QM10 
200/5 A 
5 
5P10 
45 
110 
70 
KTP2R200QM20 
5P20 
110 
120 
KTP2R250QM10 
250/5 A 
5 
5P10 
45 
110 
60 
KTP2R250QM20 
5P20 
110 
115 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
Part Number 
Class 
OD 
HT 
KTP3R300TM10 
300/5 A 
15 
5P10 
55 
140 
80 
KTP3R300TM5 
5P5 
130 
60 
KTP3R400TM10 
400/5 A 
15 
5P10 
55 
140 
70 
KTP3R400TM20 
5P20 
130 
140 
KTP3R500TM10 
500/5 A 
15 
5P10 
55 
130 
65 
KTP3R500TM20 
5P20 
140 
110 
KTP3R600TM10 
600/5 A 
15 
5P10 
55 
135 
65 
KTP3R600TM20 
5P20 
145 
100 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
Part Number 
Class 
OD 
HT 
KTP4R600TM10 
600/5 A 
15 
5P10 
70 
145 
60 
KTP4R600TM20 
5P20 
145 
110 
KTP4R800TM10 
800/5 A 
15 
5P10 
70 
150 
55 
KTP4R800TM20 
5P20 
150 
95 
KTP4R1000TM10 
1000/5 A 
15 
5P10 
70 
150 
50 
KTP4R1000TM20 
5P20 
150 
80 
KTP4R1200TM10 
1200/5 A 
15 
5P10 
70 
150 
50 
KTP4R1200TM20 
5P20 
150 
75 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
Part Number 
Class 
OD 
HT 
KTP5R800TM10 
800/5 A 
15 
5P10 
85 
170 
55 
KTP5R800TM20 
5P20 
180 
80
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 44 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
KTP5R1000TM10 
1000/5 A 
15 
5P10 
85 
170 
50 
KTP5R1000TM20 
5P20 
170 
80 
KTP5R1200TM10 
1200/5 A 
15 
5P10 
85 
170 
50 
KTP5R1200TM20 
5P20 
180 
65 
KTP5R1600TM10 
1600/5 A 
15 
5P10 
85 
170 
45 
KTP5R1600TM20 
5P20 
180 
55 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
Part Number 
Class 
OD 
HT 
KTP6R2000TM10 
2000/5 A 
15 
5P10 
115 
190 
50 
KTP6R2000TM20 
5P20 
195 
65 
KTP6R2500TM10 
2500/5 A 
15 
5P10 
115 
190 
45 
KTP6R2500TM20 
5P20 
195 
60 
KTP6R3000TM10 
3000/5 A 
15 
5P10 
115 
190 
45 
KTP6R3000TM20 
5P20 
200 
60 
KTP6R3500TM10 
3500/5 A 
15 
5P10 
115 
195 
50 
KTP6R3500TM20 
5P20 
215 
50
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 45 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
5.2.3 Protection - Resin Cast Ring Type - KRP Series 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
Part Number 
Class 
OD 
HT 
KRP1R100QL5 
100/5 A 
5 
10P5 
30 
100 
75 
KRP1R100QM10 
5P10 
90 
135 
KRP1R100SL5 
100/5 A 
10 
10P5 
30 
90 
135 
KRP1R100SM10 
5P10 
120 
145 
KRP1R150QM5 
150/5 A 
5 
5P5 
30 
80 
70 
KRP1R150QM10 
5P10 
100 
100 
KRP1R150RL10 
150/5 A 
7.5 
10P10 
30 
90 
135 
KRP1R150RM10 
5P10 
90 
135 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
Part Number 
Class 
OD 
HT 
KRP2R100QL5 
100/5 A 
5 
10P5 
45 
100 
100 
KRP2R100QM10 
5P10 
105 
135 
KRP2R100SL5 
100/5 A 
10 
10P5 
45 
105 
120 
KRP2R100SM10 
5P10 
155 
130 
KRP2R200SM10 
200/5 A 
10 
5P20 
45 
105 
135 
KRP2R200SM20 
5P20 
145 
160 
KRP2R250SM10 
250/5 A 
10 
5P20 
45 
105 
120 
KRP2R250SM20 
5P20 
155 
110 
KRP2R300TM10 
300/5 A 
15 
5P20 
45 
105 
135 
KRP2R300TM5 
5P5 
100 
100 
KRP2R400TM10 
400/5 A 
15 
5P20 
45 
105 
120 
KRP2R400TM20 
5P20 
145 
100 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
Part Number 
Class 
OD 
HT 
KRP3R400TM10 
400/5 A 
15 
5P20 
55 
140 
70 
KRP3R400TM20 
5P20 
155 
130 
KRP3R450TM10 
450/5 A 
15 
5P20 
55 
120 
90 
KRP3R450TM20 
5P20 
155 
110 
KRP3R500TM10 
500/5 A 
15 
5P20 
55 
140 
70 
KRP3R500TM20 
5P20 
145 
100 
KRP3R600TM10 
600/5 A 
15 
5P20 
55 
140 
70 
KRP3R600TM20 
5P20 
145 
100 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
Part Number 
Class 
OD 
HT 
KRP4R600TM10 
600/5 A 
15 
5P20 
70 
140 
70 
KRP4R600TM20 
5P20 
155 
110 
KRP4R800TM10 
800/5 A 
15 
5P20 
70 
140 
70 
KRP4R800TM20 
5P20 
145 
100 
KRP4R1000TM10 
1000/5 A 
15 
5P20 
70 
140 
70 
KRP4R1000TM20 
5P20 
155 
90 
KRP4R1200TM10 
1200/5 A 
15 
5P20 
70 
140 
70 
KRP4R1200TM20 
5P20 
155 
90 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
Part Number 
Class 
OD 
HT
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 46 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
KRP5R800TM10 
800/5 A 
15 
5P20 
85 
165 
60 
KRP5R800TM20 
5P20 
190 
75 
KRP5R1000TM10 
1000/5 A 
15 
5P20 
85 
165 
60 
KRP5R1000TM20 
5P20 
190 
75 
KRP5R1200TM10 
1200/5 A 
15 
5P20 
85 
165 
60 
KRP5R1200TM20 
5P20 
190 
75 
KRP5R1600TM10 
1600/5 A 
15 
5P20 
85 
165 
60 
KRP5R1600TM20 
5P20 
190 
75 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
Part Number 
Class 
OD 
HT 
KRP6R1000TM10 
1000/5 A 
15 
5P20 
115 
190 
75 
KRP6R1000TM20 
5P20 
190 
90 
KRP6R1200TM10 
1200/5 A 
15 
5P20 
115 
190 
75 
KRP6R1200TM20 
5P20 
190 
75 
KRP6R1600TM10 
1600/5 A 
15 
5P20 
115 
190 
75 
KRP6R1600TM20 
5P20 
190 
75 
KRP6R2000TM10 
2000/5 A 
15 
5P20 
115 
190 
35 
KRP6R2000TM20 
5P20 
190 
75 
KRP6R2500TM10 
2500/5 A 
15 
5P20 
115 
190 
75 
KRP6R2500TM20 
5P20 
190 
75 
KRP6R3000TM10 
3000/5 A 
15 
5P20 
115 
190 
75 
KRP6R3000TM20 
5P20 
190 
75 
KRP6R3500TM10 
3500/5 A 
15 
5P20 
115 
190 
75 
KRP6R3500TM20 
5P20 
205 
115
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 47 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
5.2.4 Protection - Resin Cast Ring Type - KSP Series 
Part Number 
Ratio 
Burden (VA) 
Class 
ID 
OD 
HT 
KSP1R100QL5 
100/5 A 
5 
10P5 
30 
100 
65 
KSP1R100SL5 
100/5 A 
10 
10P5 
30 
125 
75 
KSP1R150RL10 
150/5 A 
7.5 
10P10 
30 
125 
75 
KSP2R100SL5 
100/5 A 
10 
10P5 
45 
140 
75 
KSP2R150RL10 
150/5 A 
7.5 
10P10 
45 
140 
75 
KSP3R600TM10 
600/5 A 
15 
5P10 
55 
125 
75 
KSP4R600TM10 
600/5 A 
15 
5P10 
70 
140 
75 
KSP4R800TM10 
800/5 A 
15 
5P10 
70 
140 
75 
KSP4R1000TM10 
1000/5 A 
15 
5P10 
70 
175 
40 
KSP4R1200TM10 
1200/5 A 
15 
5P10 
70 
140 
75 
KSP5R800TM10 
800/5 A 
15 
5P10 
85 
175 
40 
KSP5R1200TM10 
1200/5 A 
15 
5P10 
85 
175 
40 
KSP5R1600TM10 
1600/5 A 
15 
5P10 
85 
175 
40 
KSP6R1000TM10 
1000/5 A 
15 
5P10 
115 
190 
85 
KSP6R1200TM10 
1200/5 A 
15 
5P10 
115 
190 
85 
KSP6R1600TM10 
1600/5 A 
15 
5P10 
115 
190 
85 
KSP6R2000TM10 
2000/5 A 
15 
5P10 
115 
190 
85 
KSP6R2500TM10 
2500/5 A 
15 
5P10 
115 
190 
85 
KSP6R3000TM10 
3000/5 A 
15 
5P10 
115 
190 
85
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 48 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
5.3 Special Purpose 
5.3.1 Summation Current Transformer 
When the current in a number of feeders need not be individually metered but summated to a single meter or instrument, a summation current transformer can be used. In consumer installation, where there is more than one feeder, it is more economical to use summation metering and for this purpose, summation Current Transformer (CT) is required. 
The summation CT consists of two or more primary windings which are connected to the feeders to be summated, and a single secondary winding which feeds a current proportional to the summated primary current. 
A typical ratio would be 5 + 5 + 5 / 5A, which means that three primary feeders of 5 Amps are to be summated to a single 5 Amps meter. 
We can custom-design to your specific requirements. 
5.3.2 Interposing Current Transformer 
Interposing types can be used to modify the secondary current from an existing line CT. This is useful for modifying secondary currents without replacing the line CTs. 
The main function of an interposing CT is to balance the currents supplied to the relay where there would otherwise be an imbalance due to the ratios of the main CTs. Interposing CTs are equipped with a wide range of taps that can be selected by the user to achieve the balance required.
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 49 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
As the name suggests, an interposing CT is installed between the secondary winding of the main CT and the relay. They can be used on the primary side or secondary side of the power transformer being protected, or both. Interposing CTs also provide a convenient method of establishing a delta connection for the elimination of zero sequence currents where this is necessary. 
5.3.3 Core Balance Current Transformer 
Core balance current transformers are intended for providing a very sensitive method of earth leakage protection on three-phase electrical systems with suitable relays. 
Cables of all phases pass through the inner diameter of the transformer and there is no output under no-fault conditions. In the event of an earth-fault a non-zero current exist and induces a changing magnetic field within the core, which in turn generates a secondary voltage which operates a relay (via burden). 
We can optimally custom-design to your specific requirements based on relay types and settings, and the required primary operating current.
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 50 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
6 Medium Voltage Products 
6.1 Monitoring Products 
6.1.1 Cable Mounted Sensor 
The LIQ60 is an intelligent transmission and distribution overhead line monitoring system and can provide: 
 Continuous monitoring and capture of critical performance data on overhead network lines up to 138kV; 
 Time-stamped event recordings; 
 Line status, fault waveform, outages, load profile, ambient and conductor temperatures, voltage sensing, displacement power factor, voltage reading (with an external insulated resistor); 
Key features include: 
 Maintenance-free 
 Rapid installation for instant intelligence 
 Intuitive software 
 Flexible remote communications options 
 SCADA protocol compatible 
 Versatile applications 
Key specifications include: 
 Fault capture range: 1A - 25kA; 
 Line frequency: 45Hz - 65Hz; 
 Operating temperature: -40°C to +70°C; 
 Ingress Protection: IP66; 
 Housing material: UV stabilised polycarbonate; 
 Dimensions: H: 315mm, D: 180mm, W: 140mm; 
 Weight: 2kg; 
 Battery powered and solar charged (2D movement 0.5W panel); and 
 Includes 4 x 2V, 2.5Ah rechargeable (SLA batteries) and last approximately 45 days without sunlight. 
 Installation: Conductor range: 6mm to 32mm. No outage required. Easily installed on energised lines using a hot stick.
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 51 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
6.1.2 Pole Mounted Sensor 
The LIQ35 is a reliable pole mounted solar powered line fault indicator (with battery backup) for use on three phase three wire, and SWER overhead line systems. The LIQ35 utilises a fault detection algorithm that adapts to network parameters and requires no configuration. 
Key features include: 
 Continuous fault indication; 
 Fault types: Permanent faults; Transient faults; Outage events; Closure events; Self- clearing faults (fault current without loss of voltage); 
 Patented adapting fault algorithm; 
 Dual magnetic field sensors for improved fault capture; 
 Voltage sensing to accurately identify outages and trips; 
 Time and data stamped event recording; 
 Recognition of line voltage return; 
 Two visual indicators displaying line status and most recent fault; 
 Inrush restraint to ensure only real faults are reported; 
 SCADA protocol compatible (DNP3); and 
 Advanced programmable options for maximum flexibility. 
Key specifications include: 
 Line voltage: 5kV to 145kV; 
 Rechargeable batteries: 4 x 2V, 2.5Ah Sealed lead-acid 
 Battery Life: up to 10 years;
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 52 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
 Solar panel: 3V, 1W; 
 Operation without solar (no active communications): 45 days; 
 Operating temperature: -40°C to +85°C; 
 Altitude: 1800m; 
 Local communications: 2.4GHz spread spectrum 50m range (line of sight); 
 Integrated remote communications: Embedded 3G cellular (PCI Express Mini Card); 
 Ambient temperature sensor (optional): -40°C to +85°C; 
 LED indicator – visibility (daylight / night time): 50m/50m; 
 Weight: 2.2kg;
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 53 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
6.2 Indoor and Outdoor Voltage Transformers 
6.2.1 Indoor Single Phase Single Pole Voltage Transformers
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 54 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
6.2.2 Indoor Single Phase Double Pole Voltage and Control Transformers
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 55 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
6.2.3 Indoor Voltage Three Phase Voltage Transformers
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 56 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 57 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
6.2.4 Draw-Out Voltage Transformers 
6.2.5 Outdoor Voltage and Control Transformers 
6.2.5.1.1 Oil Immersed Version 
6.2.5.1.2 Cast Resin Version
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 58 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
6.2.6 Outdoor Metering Units 
6.3 Indoor and Outdoor Current Transformers 
6.3.1 Indoor Ring Type, Window Type and Bus Duct (up to 36kV) 
 Typically for currents of 200A and above - depending on burden and accuracy requirements. 
 Inner diameters from 65 mm to 170 mm available for ring type, and up to (110 x 75) mm for window type. 
 Pigtail is provided for CTs of rating 6.6 kV and above, and should be connected to the primary bar to obtain an equi-potential (discharge-free) connection. 
 Large diameter bus duct CTs are available, suitable for up to 30000 A. 
 Suitable for high short time ratings.
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 59 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
6.3.2 Indoor Bar Primary Current Transformers (up to 36kV)
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 60 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
6.3.3 Indoor Wound Primary (block Type) Current Transformers (up to 36kV) 
Suitable for current ratings up to 4000A: 
 Primary connecting pad sizes vary depending upon primary current 
 Standard frame widths of 148, 160, 180, 205, 240 mm 
 Suitable for short time rating of 50 kA/3 seconds
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 61 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
6.3.4 Outdoor Current Transformers
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 62 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
7 Power Quality Mitigation Products 
7.1 Reactors and Filters 
We can source appropriate line side and load side reactors and filters to address the identified causes of poor power quality. 
7.2 Power Factor Correction Units 
We work with local manufacturers and suppliers to provide appropriately sized PFC units. We can custom design to your requirements and also offer a segregated design that not only enables more efficient service and maintenance but also ensures the sensitive control components are not affected by heat generated by the harmonic blocking reactors and hence prolonging the life of the equipment. 
Up to 100kVar Wall Mount Cubicle 
1000H x 800W x 300D (wall mount cubicle without reactor segregation) 
Up to 250kVar Cubicle 
2000H x 800W x 600D (expandable to 300kVar if no isolator or circuit breaker required) 
Up to 550kVar Cubicle 
2000H x 1250W x 600D (expandable to 600kVar if no isolator or circuit breaker required) 
Up to 800kVar Cubicle 
2000H x 2050W x 600D (expandable to 900kVar if no isolator or circuit breaker required) 
Up to 1000kVar Cubicle 
2000H x 2500W x 600D 
Switched Capacitor Bank: 
Thyristor controlled switching technology - mitigates the effects of fast switching loads (lifts, welding equipment, oil and gas drilling rigs; and mine site drilling equipment).
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 63 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
7.3 Active Harmonic Filtering 
Wall-Mounted Active Filter ADF P100 
The ADF P100 is an ultra-efficient, easy to use solution in a wall mounted cabinet. The tall and narrow design allows installation where space is at a premium. It has a nominal current of 70 to 100 A RMS and is available in the voltage range 208 - 480 V RMS nominal. 
ADF P200 Active Filter 
The ADF P200 is a very fast active filter and can eliminate harmonic problems up to the 100th harmonic and works well in even very resonant grids. It is suitable for mitigating resonances, interharmonics and high frequency disturbances. 
ADF P300 Active Filter 
The ADF P300 is suitable for commercial and industrial loads. 
STATCOM (Static Synchronous Compensator) Is a shunt device, which uses force-commutated power electronics (i.e. GTO, IGBT) to control power flow and improve transient stability on electrical power networks.
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 64 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
ADF P700 STATCOM: 
The ADF P700 is a high power, utility grade, medium voltage STATCOM for heavy industrial loads. It is useful for dynamic reactive compensation, flicker mitigation, and harmonic suppression in applications such as electric arc furnaces, cranes, hoists and wind farms. 
The ADF P700 is available in modular 3 MVA or 6 MVA compensation power. Several units can be operated in parallel to achieve higher power levels.
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 65 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
8 Consulting and Services 
8.1 Consulting in Power Quality 
8.1.1 Power Quality Investigation 
This includes: 
 Site Survey 
 Site Monitoring 
 Data Analysis and Identification 
 Reporting and Recommendations 
8.1.2 Power Quality Mitigation 
Following the Power Quality Investigation, we then propose solutions to mitigate the contributing aspects to poor power quality. This includes proposing products and equipment followed by further monitoring for validation. 
8.1.3 Power Quality Management 
Your electrical distribution system may be changing - growing (adding more elements to do more work). In this case we would recommend a Power Quality Management Plan for continuous monitoring and assessment. 
8.2 Training 
8.2.1 Product Training 
Product training is provided on all electronic monitoring products and customised equipment sold and or designed by CHK Power Quality Pty Ltd. 
8.2.2 Professional Training 
A single day course is offered in Power Quality with a certificate awarded upon completion. The course covers an overview of power systems in Australia, introduces concepts of power quality, monitoring and reporting and how to improve power quality. 
8.3 Technical Support 
8.3.1 Product Support 
Product support is provided on all electronic monitoring products and customised equipment sold and or designed by CHK Power Quality Pty Ltd and some products designed by GridSense; please enquire. 
8.3.2 Calibration and Repairs 
We have a service department that provide repairs and calibration for our electronic products.
PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 66 
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; 
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 
Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 
Website: www.chkpowerquality.com.au ABN: 53 169 840 831 
8.4 Low Volume Contract Manufacturing 
We have over fifteen years of experience in low volume production. Items include: wire looms; leads and probes; building electronic circuit boards (hand soldering) and product sub-assemblies. 
8.5 Engineering and Project Management Services 
8.5.1 Feature Requests and New Features 
Where possible, we can update a product to include a specific feature to address your requirement. 
8.5.2 Design 
Our engineering team can custom-design a solution (involving industrial design, electronic, firmware and software development) and manage the whole product development cycle, from specification to testing and approvals.

More Related Content

What's hot

Daewoo doosan dx300 lc excavator operation and maintenance manual
Daewoo doosan dx300 lc excavator operation and maintenance manualDaewoo doosan dx300 lc excavator operation and maintenance manual
Daewoo doosan dx300 lc excavator operation and maintenance manualudfjjjskekmdm
 
Energy Systems Optimization Of A Shopping Mall
Energy Systems Optimization Of A Shopping MallEnergy Systems Optimization Of A Shopping Mall
Energy Systems Optimization Of A Shopping MallAristotelisGiannopoulos
 
Advent Net Manage Engine Service Desk Plus Help Admin Guide
Advent Net Manage Engine Service Desk Plus Help Admin GuideAdvent Net Manage Engine Service Desk Plus Help Admin Guide
Advent Net Manage Engine Service Desk Plus Help Admin Guideguestf80501
 
Adventnetmanageengineservicedeskplushelpadminguide 090929051027-p hpapp02
Adventnetmanageengineservicedeskplushelpadminguide 090929051027-p hpapp02Adventnetmanageengineservicedeskplushelpadminguide 090929051027-p hpapp02
Adventnetmanageengineservicedeskplushelpadminguide 090929051027-p hpapp02Phạm Tiệp
 
Clark op15 x forklift service repair manual
Clark op15 x forklift service repair manualClark op15 x forklift service repair manual
Clark op15 x forklift service repair manualfjjskekdmme
 
B.E thesis Shubham Nivasarkar
B.E thesis Shubham NivasarkarB.E thesis Shubham Nivasarkar
B.E thesis Shubham Nivasarkarshubhamnivasarkar
 
SolTrK_data_sheet solar control
SolTrK_data_sheet solar controlSolTrK_data_sheet solar control
SolTrK_data_sheet solar controlHossam Zein
 

What's hot (9)

Daewoo doosan dx300 lc excavator operation and maintenance manual
Daewoo doosan dx300 lc excavator operation and maintenance manualDaewoo doosan dx300 lc excavator operation and maintenance manual
Daewoo doosan dx300 lc excavator operation and maintenance manual
 
Bucher lift control guide
Bucher lift control guideBucher lift control guide
Bucher lift control guide
 
Energy Systems Optimization Of A Shopping Mall
Energy Systems Optimization Of A Shopping MallEnergy Systems Optimization Of A Shopping Mall
Energy Systems Optimization Of A Shopping Mall
 
Advent Net Manage Engine Service Desk Plus Help Admin Guide
Advent Net Manage Engine Service Desk Plus Help Admin GuideAdvent Net Manage Engine Service Desk Plus Help Admin Guide
Advent Net Manage Engine Service Desk Plus Help Admin Guide
 
Adventnetmanageengineservicedeskplushelpadminguide 090929051027-p hpapp02
Adventnetmanageengineservicedeskplushelpadminguide 090929051027-p hpapp02Adventnetmanageengineservicedeskplushelpadminguide 090929051027-p hpapp02
Adventnetmanageengineservicedeskplushelpadminguide 090929051027-p hpapp02
 
Clark op15 x forklift service repair manual
Clark op15 x forklift service repair manualClark op15 x forklift service repair manual
Clark op15 x forklift service repair manual
 
B.E thesis Shubham Nivasarkar
B.E thesis Shubham NivasarkarB.E thesis Shubham Nivasarkar
B.E thesis Shubham Nivasarkar
 
SolTrK_data_sheet solar control
SolTrK_data_sheet solar controlSolTrK_data_sheet solar control
SolTrK_data_sheet solar control
 
Submerged pump
Submerged pump Submerged pump
Submerged pump
 

Viewers also liked

Showbox time! (Project Proposal)
Showbox time! (Project Proposal)Showbox time! (Project Proposal)
Showbox time! (Project Proposal)Clorama Dorvilias
 
бутко конфереція1
бутко конфереція1бутко конфереція1
бутко конфереція1Tamara Emec
 
Boneal Cốt Thống Linh
Boneal Cốt Thống LinhBoneal Cốt Thống Linh
Boneal Cốt Thống Linhgregory838
 
Chệch đĩa đệm Cột Sống
Chệch đĩa đệm Cột SốngChệch đĩa đệm Cột Sống
Chệch đĩa đệm Cột Sốngjewell530
 
Name of the teacher sujina
Name of the teacher   sujinaName of the teacher   sujina
Name of the teacher sujinaAjila S
 
Media final evaluation
Media final evaluationMedia final evaluation
Media final evaluationlh193
 
Step by-step-menginstal-windows-vista
Step by-step-menginstal-windows-vistaStep by-step-menginstal-windows-vista
Step by-step-menginstal-windows-vistaBudi Permana
 
Thay đĩa đệm Nhân Tạo
Thay đĩa đệm Nhân TạoThay đĩa đệm Nhân Tạo
Thay đĩa đệm Nhân Tạoleroy446
 
Step by-step-menginstall-windows-xp
Step by-step-menginstall-windows-xpStep by-step-menginstall-windows-xp
Step by-step-menginstall-windows-xpBudi Permana
 
Ways to sell more of your own listings
Ways to sell more of your own listingsWays to sell more of your own listings
Ways to sell more of your own listingsPranav Pandya
 
Yachay 8
Yachay 8Yachay 8
Yachay 8Jean Px
 
The cheapest methods for cancer prevention
The cheapest methods for cancer preventionThe cheapest methods for cancer prevention
The cheapest methods for cancer preventionRenkang Hospital
 
Thoai Hoa Khop Dau Goi
Thoai Hoa Khop Dau GoiThoai Hoa Khop Dau Goi
Thoai Hoa Khop Dau Goiamalia616
 
Remya powerpoint 111
Remya powerpoint 111Remya powerpoint 111
Remya powerpoint 1119526885267
 

Viewers also liked (20)

Showbox time! (Project Proposal)
Showbox time! (Project Proposal)Showbox time! (Project Proposal)
Showbox time! (Project Proposal)
 
бутко конфереція1
бутко конфереція1бутко конфереція1
бутко конфереція1
 
Actividad #2
Actividad #2Actividad #2
Actividad #2
 
Leonardo da vinci
Leonardo da vinciLeonardo da vinci
Leonardo da vinci
 
Bio Data
Bio DataBio Data
Bio Data
 
Boneal Cốt Thống Linh
Boneal Cốt Thống LinhBoneal Cốt Thống Linh
Boneal Cốt Thống Linh
 
Chệch đĩa đệm Cột Sống
Chệch đĩa đệm Cột SốngChệch đĩa đệm Cột Sống
Chệch đĩa đệm Cột Sống
 
Name of the teacher sujina
Name of the teacher   sujinaName of the teacher   sujina
Name of the teacher sujina
 
El lenguaje
El lenguajeEl lenguaje
El lenguaje
 
Media final evaluation
Media final evaluationMedia final evaluation
Media final evaluation
 
Step by-step-menginstal-windows-vista
Step by-step-menginstal-windows-vistaStep by-step-menginstal-windows-vista
Step by-step-menginstal-windows-vista
 
Thay đĩa đệm Nhân Tạo
Thay đĩa đệm Nhân TạoThay đĩa đệm Nhân Tạo
Thay đĩa đệm Nhân Tạo
 
Step by-step-menginstall-windows-xp
Step by-step-menginstall-windows-xpStep by-step-menginstall-windows-xp
Step by-step-menginstall-windows-xp
 
Ways to sell more of your own listings
Ways to sell more of your own listingsWays to sell more of your own listings
Ways to sell more of your own listings
 
Atikah
Atikah Atikah
Atikah
 
Yachay 8
Yachay 8Yachay 8
Yachay 8
 
The cheapest methods for cancer prevention
The cheapest methods for cancer preventionThe cheapest methods for cancer prevention
The cheapest methods for cancer prevention
 
Thoai Hoa Khop Dau Goi
Thoai Hoa Khop Dau GoiThoai Hoa Khop Dau Goi
Thoai Hoa Khop Dau Goi
 
Remya powerpoint 111
Remya powerpoint 111Remya powerpoint 111
Remya powerpoint 111
 
Arghel
ArghelArghel
Arghel
 

Similar to CHK Power Quality products & services catalogue 22 sep 14 release

exfo_book_guide-wdm_en.pdf
exfo_book_guide-wdm_en.pdfexfo_book_guide-wdm_en.pdf
exfo_book_guide-wdm_en.pdfMohamedshabana38
 
Miele Gas Dryer T9820 Service Manual
Miele Gas Dryer T9820 Service ManualMiele Gas Dryer T9820 Service Manual
Miele Gas Dryer T9820 Service ManualAjit Verma
 
PowerElectronicsHandbookbyMuhammadH.Rashid.pdf
PowerElectronicsHandbookbyMuhammadH.Rashid.pdfPowerElectronicsHandbookbyMuhammadH.Rashid.pdf
PowerElectronicsHandbookbyMuhammadH.Rashid.pdfssuser19b225
 
Catalog hitachi 50 hitachi-tr-series_dienhathe.org
Catalog hitachi 50 hitachi-tr-series_dienhathe.orgCatalog hitachi 50 hitachi-tr-series_dienhathe.org
Catalog hitachi 50 hitachi-tr-series_dienhathe.orgDien Ha The
 
E82 ev _8200 vector 0.25-90kw__v3-0__en
E82 ev _8200 vector 0.25-90kw__v3-0__enE82 ev _8200 vector 0.25-90kw__v3-0__en
E82 ev _8200 vector 0.25-90kw__v3-0__enCharles Santos
 
Electronics en engineering-basic-vocational-knowledge
Electronics en engineering-basic-vocational-knowledgeElectronics en engineering-basic-vocational-knowledge
Electronics en engineering-basic-vocational-knowledgesandeep patil
 
Endversion1 skriptum characterization of miscellaneous multi parametrical sil...
Endversion1 skriptum characterization of miscellaneous multi parametrical sil...Endversion1 skriptum characterization of miscellaneous multi parametrical sil...
Endversion1 skriptum characterization of miscellaneous multi parametrical sil...EjderCevher
 
Operations manual for_owners_and_managers_multi-unit_residential_buildings
Operations manual for_owners_and_managers_multi-unit_residential_buildingsOperations manual for_owners_and_managers_multi-unit_residential_buildings
Operations manual for_owners_and_managers_multi-unit_residential_buildingsSherry Schluessel
 
Digital Control in Power Electronics - Buso & Mattavelli - 2006.pdf
Digital Control in Power Electronics - Buso & Mattavelli - 2006.pdfDigital Control in Power Electronics - Buso & Mattavelli - 2006.pdf
Digital Control in Power Electronics - Buso & Mattavelli - 2006.pdfGollapalli Sreenivasulu
 
Digital Control in Power Electronics.pdf
Digital Control in Power Electronics.pdfDigital Control in Power Electronics.pdf
Digital Control in Power Electronics.pdfGollapalli Sreenivasulu
 
High Voltage DC Surge Arresters for Railway Industry - Overvoltage Protection...
High Voltage DC Surge Arresters for Railway Industry - Overvoltage Protection...High Voltage DC Surge Arresters for Railway Industry - Overvoltage Protection...
High Voltage DC Surge Arresters for Railway Industry - Overvoltage Protection...Thorne & Derrick International
 
Spm6600 Dx6i Manual Lo Res
Spm6600 Dx6i Manual Lo ResSpm6600 Dx6i Manual Lo Res
Spm6600 Dx6i Manual Lo Resguestada3c8
 
Datacolor 650 600 400 Users Guide 4230 0395 M Rev 1
Datacolor 650 600 400 Users Guide 4230 0395 M Rev 1Datacolor 650 600 400 Users Guide 4230 0395 M Rev 1
Datacolor 650 600 400 Users Guide 4230 0395 M Rev 1Andreas Peny
 
2016.10.24 halvledere - pdf v.01 - DIODE TRANSISTOR SEMICONDUCTOR - Sven ...
2016.10.24   halvledere - pdf v.01  -  DIODE TRANSISTOR SEMICONDUCTOR - Sven ...2016.10.24   halvledere - pdf v.01  -  DIODE TRANSISTOR SEMICONDUCTOR - Sven ...
2016.10.24 halvledere - pdf v.01 - DIODE TRANSISTOR SEMICONDUCTOR - Sven ...Sven Åge Eriksen
 
New holland td90 tractor service repair manual
New holland td90 tractor service repair manualNew holland td90 tractor service repair manual
New holland td90 tractor service repair manualiekkdmmem
 

Similar to CHK Power Quality products & services catalogue 22 sep 14 release (20)

exfo_book_guide-wdm_en.pdf
exfo_book_guide-wdm_en.pdfexfo_book_guide-wdm_en.pdf
exfo_book_guide-wdm_en.pdf
 
Miele Gas Dryer T9820 Service Manual
Miele Gas Dryer T9820 Service ManualMiele Gas Dryer T9820 Service Manual
Miele Gas Dryer T9820 Service Manual
 
PowerElectronicsHandbookbyMuhammadH.Rashid.pdf
PowerElectronicsHandbookbyMuhammadH.Rashid.pdfPowerElectronicsHandbookbyMuhammadH.Rashid.pdf
PowerElectronicsHandbookbyMuhammadH.Rashid.pdf
 
Catalog hitachi 50 hitachi-tr-series_dienhathe.org
Catalog hitachi 50 hitachi-tr-series_dienhathe.orgCatalog hitachi 50 hitachi-tr-series_dienhathe.org
Catalog hitachi 50 hitachi-tr-series_dienhathe.org
 
E82 ev _8200 vector 0.25-90kw__v3-0__en
E82 ev _8200 vector 0.25-90kw__v3-0__enE82 ev _8200 vector 0.25-90kw__v3-0__en
E82 ev _8200 vector 0.25-90kw__v3-0__en
 
Alnor hvac handbook
Alnor hvac handbookAlnor hvac handbook
Alnor hvac handbook
 
Electronics en engineering-basic-vocational-knowledge
Electronics en engineering-basic-vocational-knowledgeElectronics en engineering-basic-vocational-knowledge
Electronics en engineering-basic-vocational-knowledge
 
Endversion1 skriptum characterization of miscellaneous multi parametrical sil...
Endversion1 skriptum characterization of miscellaneous multi parametrical sil...Endversion1 skriptum characterization of miscellaneous multi parametrical sil...
Endversion1 skriptum characterization of miscellaneous multi parametrical sil...
 
Tilak's Report
Tilak's ReportTilak's Report
Tilak's Report
 
Operations manual for_owners_and_managers_multi-unit_residential_buildings
Operations manual for_owners_and_managers_multi-unit_residential_buildingsOperations manual for_owners_and_managers_multi-unit_residential_buildings
Operations manual for_owners_and_managers_multi-unit_residential_buildings
 
Digital Control in Power Electronics - Buso & Mattavelli - 2006.pdf
Digital Control in Power Electronics - Buso & Mattavelli - 2006.pdfDigital Control in Power Electronics - Buso & Mattavelli - 2006.pdf
Digital Control in Power Electronics - Buso & Mattavelli - 2006.pdf
 
Digital Control in Power Electronics.pdf
Digital Control in Power Electronics.pdfDigital Control in Power Electronics.pdf
Digital Control in Power Electronics.pdf
 
High Voltage DC Surge Arresters for Railway Industry - Overvoltage Protection...
High Voltage DC Surge Arresters for Railway Industry - Overvoltage Protection...High Voltage DC Surge Arresters for Railway Industry - Overvoltage Protection...
High Voltage DC Surge Arresters for Railway Industry - Overvoltage Protection...
 
Spm6600 Dx6i Manual Lo Res
Spm6600 Dx6i Manual Lo ResSpm6600 Dx6i Manual Lo Res
Spm6600 Dx6i Manual Lo Res
 
P drive m xpro
P drive m xproP drive m xpro
P drive m xpro
 
Datacolor 650 600 400 Users Guide 4230 0395 M Rev 1
Datacolor 650 600 400 Users Guide 4230 0395 M Rev 1Datacolor 650 600 400 Users Guide 4230 0395 M Rev 1
Datacolor 650 600 400 Users Guide 4230 0395 M Rev 1
 
2016.10.24 halvledere - pdf v.01 - DIODE TRANSISTOR SEMICONDUCTOR - Sven ...
2016.10.24   halvledere - pdf v.01  -  DIODE TRANSISTOR SEMICONDUCTOR - Sven ...2016.10.24   halvledere - pdf v.01  -  DIODE TRANSISTOR SEMICONDUCTOR - Sven ...
2016.10.24 halvledere - pdf v.01 - DIODE TRANSISTOR SEMICONDUCTOR - Sven ...
 
DNV Liquified Gas Terminal
DNV Liquified Gas TerminalDNV Liquified Gas Terminal
DNV Liquified Gas Terminal
 
Sr1188 manual-ultisolar-new-energy-co-ltd-solar-water-heaters-controllers-woo...
Sr1188 manual-ultisolar-new-energy-co-ltd-solar-water-heaters-controllers-woo...Sr1188 manual-ultisolar-new-energy-co-ltd-solar-water-heaters-controllers-woo...
Sr1188 manual-ultisolar-new-energy-co-ltd-solar-water-heaters-controllers-woo...
 
New holland td90 tractor service repair manual
New holland td90 tractor service repair manualNew holland td90 tractor service repair manual
New holland td90 tractor service repair manual
 

More from Ajeesh Joseph

Transformer monitor and logger
Transformer monitor and loggerTransformer monitor and logger
Transformer monitor and loggerAjeesh Joseph
 
Technical note Miro automatic ftp uploads - r 30 sep 16
Technical note   Miro automatic ftp uploads - r 30 sep 16Technical note   Miro automatic ftp uploads - r 30 sep 16
Technical note Miro automatic ftp uploads - r 30 sep 16Ajeesh Joseph
 
Technical note configuring the miro for cellular communications - r 30 sep 16
Technical note   configuring the miro for cellular communications - r 30 sep 16Technical note   configuring the miro for cellular communications - r 30 sep 16
Technical note configuring the miro for cellular communications - r 30 sep 16Ajeesh Joseph
 
Brochure - Maximum demand indicator using Mirrin
Brochure - Maximum demand indicator using MirrinBrochure - Maximum demand indicator using Mirrin
Brochure - Maximum demand indicator using MirrinAjeesh Joseph
 
Brochure - Pole top Transformer Monitoring using Mirrin
Brochure - Pole top Transformer Monitoring using MirrinBrochure - Pole top Transformer Monitoring using Mirrin
Brochure - Pole top Transformer Monitoring using MirrinAjeesh Joseph
 
Brochure pq investigations
Brochure pq investigationsBrochure pq investigations
Brochure pq investigationsAjeesh Joseph
 
Miro class a power quality analyzer and logger.compressed
Miro class a power quality analyzer and logger.compressedMiro class a power quality analyzer and logger.compressed
Miro class a power quality analyzer and logger.compressedAjeesh Joseph
 
Power monic application notes chk power quality
Power monic application notes chk power qualityPower monic application notes chk power quality
Power monic application notes chk power qualityAjeesh Joseph
 
Miro power quality analyser Class A user manual Apr-2016-compressed
Miro power quality analyser Class A user manual Apr-2016-compressedMiro power quality analyser Class A user manual Apr-2016-compressed
Miro power quality analyser Class A user manual Apr-2016-compressedAjeesh Joseph
 
Pm45 brochure a4 25 sep08
Pm45 brochure a4 25 sep08Pm45 brochure a4 25 sep08
Pm45 brochure a4 25 sep08Ajeesh Joseph
 
Typical applications for mirrin ll400 load logger
Typical applications for mirrin ll400 load loggerTypical applications for mirrin ll400 load logger
Typical applications for mirrin ll400 load loggerAjeesh Joseph
 

More from Ajeesh Joseph (12)

Transformer monitor and logger
Transformer monitor and loggerTransformer monitor and logger
Transformer monitor and logger
 
Technical note Miro automatic ftp uploads - r 30 sep 16
Technical note   Miro automatic ftp uploads - r 30 sep 16Technical note   Miro automatic ftp uploads - r 30 sep 16
Technical note Miro automatic ftp uploads - r 30 sep 16
 
Technical note configuring the miro for cellular communications - r 30 sep 16
Technical note   configuring the miro for cellular communications - r 30 sep 16Technical note   configuring the miro for cellular communications - r 30 sep 16
Technical note configuring the miro for cellular communications - r 30 sep 16
 
Brochure - Maximum demand indicator using Mirrin
Brochure - Maximum demand indicator using MirrinBrochure - Maximum demand indicator using Mirrin
Brochure - Maximum demand indicator using Mirrin
 
Brochure - Pole top Transformer Monitoring using Mirrin
Brochure - Pole top Transformer Monitoring using MirrinBrochure - Pole top Transformer Monitoring using Mirrin
Brochure - Pole top Transformer Monitoring using Mirrin
 
Brochure pq investigations
Brochure pq investigationsBrochure pq investigations
Brochure pq investigations
 
Miro class a power quality analyzer and logger.compressed
Miro class a power quality analyzer and logger.compressedMiro class a power quality analyzer and logger.compressed
Miro class a power quality analyzer and logger.compressed
 
Power monic application notes chk power quality
Power monic application notes chk power qualityPower monic application notes chk power quality
Power monic application notes chk power quality
 
Miro power quality analyser Class A user manual Apr-2016-compressed
Miro power quality analyser Class A user manual Apr-2016-compressedMiro power quality analyser Class A user manual Apr-2016-compressed
Miro power quality analyser Class A user manual Apr-2016-compressed
 
Liq 60 tech spec
Liq 60 tech specLiq 60 tech spec
Liq 60 tech spec
 
Pm45 brochure a4 25 sep08
Pm45 brochure a4 25 sep08Pm45 brochure a4 25 sep08
Pm45 brochure a4 25 sep08
 
Typical applications for mirrin ll400 load logger
Typical applications for mirrin ll400 load loggerTypical applications for mirrin ll400 load logger
Typical applications for mirrin ll400 load logger
 

Recently uploaded

MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSSIVASHANKAR N
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVRajaP95
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxpranjaldaimarysona
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...Soham Mondal
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingrakeshbaidya232001
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSKurinjimalarL3
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )Tsuyoshi Horigome
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxupamatechverse
 
Internship report on mechanical engineering
Internship report on mechanical engineeringInternship report on mechanical engineering
Internship report on mechanical engineeringmalavadedarshan25
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerAnamika Sarkar
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxupamatechverse
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Dr.Costas Sachpazis
 
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...Call Girls in Nagpur High Profile
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile servicerehmti665
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINESIVASHANKAR N
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Serviceranjana rawat
 

Recently uploaded (20)

Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptx
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptx
 
Internship report on mechanical engineering
Internship report on mechanical engineeringInternship report on mechanical engineering
Internship report on mechanical engineering
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
 
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINEDJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptx
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
 
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile service
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
 

CHK Power Quality products & services catalogue 22 sep 14 release

  • 1. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 1 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 PRODUCTS AND SERVICES CATALOGUE Contents 1 POWER QUALITY ANALYSERS ...................................................................................... 4 1.1 GRIDSENSE POWERMONIC ............................................................................. 4 1.1.1 Introduction ......................................................................................................... 4 1.1.2 Key Features ...................................................................................................... 4 1.1.3 Current Sensor Options ...................................................................................... 5 1.1.4 Specifications ..................................................................................................... 5 1.2 SUIN SA2100 ...................................................................................................... 7 1.2.1 Introduction ......................................................................................................... 7 1.2.2 Key Features ...................................................................................................... 7 1.2.3 Current Sensor Options ...................................................................................... 7 1.2.4 Voltage Leads .................................................................................................... 9 1.2.5 Flexible Current Probe ..................................................................................... 10 1.2.6 Carry Bag ......................................................................................................... 10 1.2.7 Kit Items............................................................................................................ 10 1.2.8 Specifications ................................................................................................... 11 1.3 ZES ZIMMER LMG500 ...................................................................................... 13 1.3.1 Introduction ....................................................................................................... 13 1.3.2 Key Features .................................................................................................... 13 1.3.3 Device Interface ............................................................................................... 14 1.3.4 Connections ..................................................................................................... 15 2 LOGGING INSTRUMENTS ............................................................................................. 16 2.1 LOAD LOGGER ................................................................................................ 16 2.1.1 Introduction ....................................................................................................... 16 2.1.2 Specifications ................................................................................................... 16 2.1.3 Installation ........................................................................................................ 17 2.1.4 Software ........................................................................................................... 17 2.1.5 Calibration ........................................................................................................ 17 3 REMOTE (ONLINE) MONITORING SYSTEMS ............................................................... 18 3.1 LOAD REMOTE ................................................................................................ 18 3.2 MONITORING BACK-UP GENERATORS ......................................................... 19 3.2.1 G8500 SINGLE GENERATOR SYSTEM ......................................................... 20 3.2.2 G8600 MULTIPLE GENERATOR SYSTEM .................................................... 21 3.2.3 G8700 MOBILE GENERATOR SYSTEM ........................................................ 22 3.2.4 G8800 RESIDENTIAL GENERATOR SYSTEM .............................................. 23 4 CURRENT PROBES AND SENSORS ............................................................................. 24 4.1 FLEXIBLE CURRENT SENSORS ..................................................................... 24 4.2 CLAMP ON CURRENT SENSORS ................................................................... 26 4.3 MINIATURE SPLIT-CORE CURRENT TRANSFORMERS ................................ 28 4.3.1 Key Features and General Specifications ........................................................ 28 4.3.2 Range ............................................................................................................... 28
  • 2. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 2 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 4.4 SUBSTATION CURRENT TRANSFORMER CONVERTERS ............................ 29 4.4.1 Introduction ....................................................................................................... 29 4.4.2 Specifications ................................................................................................... 29 5 INSTRUMENT CURRENT TRANSFORMERS ................................................................ 30 5.1 METERING ....................................................................................................... 31 5.1.1 Measuring - PVC .............................................................................................. 31 5.1.2 Measuring - MBQ Series .................................................................................. 32 5.1.3 Measuring - MSQ Series .................................................................................. 33 5.1.4 Measuring - Tape Insulated Ring Type - KTM Series ...................................... 35 5.1.5 Measuring - Resin Cast Ring Type - KRM Series ............................................ 38 5.1.6 Measuring - Resin Cast Ring Type - KSM Series ............................................ 40 5.2 PROTECTION ................................................................................................... 42 5.2.1 Protection - PVC ............................................................................................... 42 5.2.2 Protection - Tape Insulated Ring Type - KTP Series ....................................... 43 5.2.3 Protection - Resin Cast Ring Type - KRP Series ............................................. 45 5.2.4 Protection - Resin Cast Ring Type - KSP Series ............................................. 47 5.3 SPECIAL PURPOSE ......................................................................................... 48 5.3.1 Summation Current Transformer ..................................................................... 48 5.3.2 Interposing Current Transformer ...................................................................... 48 5.3.3 Core Balance Current Transformer .................................................................. 49 6 MEDIUM VOLTAGE PRODUCTS ................................................................................... 50 6.1 MONITORING PRODUCTS .............................................................................. 50 6.1.1 Cable Mounted Sensor ..................................................................................... 50 6.1.2 Pole Mounted Sensor ....................................................................................... 51 6.2 INDOOR AND OUTDOOR VOLTAGE TRANSFORMERS ................................ 53 6.2.1 Indoor Single Phase Single Pole Voltage Transformers .................................. 53 6.2.2 Indoor Single Phase Double Pole Voltage and Control Transformers ............. 54 6.2.3 Indoor Voltage Three Phase Voltage Transformers ........................................ 55 6.2.4 Draw-Out Voltage Transformers ...................................................................... 57 6.2.5 Outdoor Voltage and Control Transformers ..................................................... 57 6.2.6 Outdoor Metering Units .................................................................................... 58 6.3 INDOOR AND OUTDOOR CURRENT TRANSFORMERS ................................ 58 6.3.1 Indoor Ring Type, Window Type and Bus Duct (up to 36kV) .......................... 58 6.3.2 Indoor Bar Primary Current Transformers (up to 36kV) ................................... 59 6.3.3 Indoor Wound Primary (block Type) Current Transformers (up to 36kV) ........ 60 6.3.4 Outdoor Current Transformers ......................................................................... 61 7 POWER QUALITY MITIGATION PRODUCTS ................................................................ 62 7.1 REACTORS AND FILTERS ............................................................................... 62 7.2 POWER FACTOR CORRECTION UNITS ......................................................... 62 7.3 ACTIVE HARMONIC FILTERING ...................................................................... 63 8 CONSULTING AND SERVICES ...................................................................................... 65 8.1 CONSULTING IN POWER QUALITY ................................................................ 65 8.1.1 Power Quality Investigation .............................................................................. 65 8.1.2 Power Quality Mitigation ................................................................................... 65 8.1.3 Power Quality Management ............................................................................. 65
  • 3. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 3 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 8.2 TRAINING ......................................................................................................... 65 8.2.1 Product Training ............................................................................................... 65 8.2.2 Professional Training ........................................................................................ 65 8.3 TECHNICAL SUPPORT .................................................................................... 65 8.3.1 Product Support ............................................................................................... 65 8.3.2 Calibration and Repairs .................................................................................... 65 8.4 LOW VOLUME CONTRACT MANUFACTURING .............................................. 66 8.5 ENGINEERING AND PROJECT MANAGEMENT SERVICES .......................... 66 8.5.1 Feature Requests and New Features .............................................................. 66 8.5.2 Design .............................................................................................................. 66
  • 4. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 4 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 1 Power Quality Analysers 1.1 GridSense Powermonic 1.1.1 Introduction The PowerMonic range of portable power recorders offers comprehensive and reliable monitoring of low voltage circuits. Built with high performance, toughness and focus on ease of use, the PowerMonic has been adopted as the workhorse instrument for a variety of power monitoring applications including power quality analysis, supply compliance checks, power flow studies, energy audits and voltage investigations. The PM45 is the latest addition to the PowerMonic product line, meeting CATIV-600V safety certification and voltage measurement standards. With four voltage and current channels, the PM45 records a trend over time along with a range of power quality parameters, including flicker, harmonics, power and imbalance in accordance to the latest IEC standards. The PM45 is also an independent event recorder capturing high resolution snapshots of fluctuations including motor starts, spikes and transients based on voltage and current limit settings. Utilized for short and long term power monitoring applications, the PM45 is typically installed on pad mount and pole mount transformers, capacitor banks, regulators, distribution substations, as well as commercial, residential and industrial connection points. Since its introduction in 1995, the PowerMonic has proven to be a reliable and versatile everyday instrument used worldwide by System Planners, Distribution Engineers, Electrical Engineers, Electrical Contractors, Power Quality Engineers, and Maintenance Engineers alike. 1.1.2 Key Features  Up to eight (8) input channels [four (4) voltage and four (4) current]  Power profiling with high-speed event capture  Transient and harmonic analysis, flicker and unbalance
  • 5. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 5 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831  Graphical LCD for measurements and recording status  Power directly from A phase - external power not required  Double insulated and fused voltage cables  Auto-scaling current transformer connection  Data download and firmware upgrade via USB  CAT IV 600V safety rating (PM45) and certified to IEC 61010  AS60529-2004 IP66 (PM45) and IP65 (PM35) protection  Wide operating temperature range: -20°C to 70°C  Wireless remote communications option available 1.1.3 Current Sensor Options Refer to sections 4.1 and 4.2. 1.1.4 Specifications PARAMETER PM45 PARAMETER PM45 Measurement General Samples per cycle 204 @ 50Hz; 170@ 60Hz Input Cannels 4 isolated voltage channels; 4 current channels Sample Rate PPL Synchronised (IEC 61000-4-7). Measurement Range A, B & c channels: 0- 600VAC; Vgnd 0 - 60 VAC (±1% reading ±1 lsd); 0- 3000A Memory 15MB internal flash Input Range Voltage: 0-600VAC (660VAC absolute); Current: 0-440mV at 10k Ohms Power Meter V, A, Min, Max, Freq,TPF, DPF, KW, KVA, KVAR Instrument Accuracy 0.4% readings + 1 lsd (current and voltage) Total Harmonic Distortion IEC 61000-4-7 (THD-F & THD-R) System Accuracy Voltage: 0.4% readings + 1 lsd; Current: 1% readings + 1 lsd Harmonics IEC 61000-4-7 (up to 48th Magnitude and Angle) Resolution Logged Data 0.001V; 0.001A Interharmonics IEC 61000-4-7 (up to 48th) Resolution LCD 0.1V; 0.1A Flicker (Pst & Plt) IEC 61000-4-15 (10min. Pst & 2hr. Plt) Voltage and Current Unbalance IEC 61000-4-30 Circuit connections Three Phase Wye/Delta, Open/2-Element Delta, Split Phase & Single Phase Instrument Type Class B (IEC 61000-4-30) Current Probe Options C10* (0-10A), C100S* (10- 125A), C500* (25-600A), Flexi F3000-6 (150-3600A) * Not CATIV-600V Rated Frequency Range 50Hz nom. (42.5-57.5) Hz 60Hz nom. (51.0-69.0) Hz Communications Direct Connection: USB Serial Cable; Remote Connection: Cellular (GPRS/3G/CDMA) High Speed Event Recording User defined Rolling and/or Threshold Voltage and Current & Transient Triggers Mechanical & Power Table Capture (Sags/Swells) Half Cycle, Min/Max & Duration Power Source - Main 60-600VAC from Phase A, and USB powered for
  • 6. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 6 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 configuration and downloading RMS Snapshot Half Cycle, 5s - 30s duration Power Source - backup Non-rechargeable batteries Waveform Snapshot Sample rate for 400ms duration Power Consumption 10W typical (from Phase A) Display Graphic LCD 128 x 64 bits (0.1 resolution) Environmental & Safety Real-Time-Clock 3V 950mAh Li-Magnanese Dioxide/Organic Electrolyte Temperature Range -20°C (-4°F) to +60°C (+130°F) Dimensions 230mm/9.1” (l) x 120mm/4.72” (w) x 90mm/3.6” (d) Humidity 20%-99% Relative Humidity Weight 7lbs (3kg) instrument only Protection Class IP66 (all weather housing) Protection levels IEC 61010-1 2001; Pollution degree 3; Measurement Category IV - 600V PM35 specifications are similar to the above with the following changes:  Protection Class: IP65;  Voltage lead connector is CAT III 600V;  No inter-harmonics.
  • 7. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 7 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 1.2 SUIN SA2100 1.2.1 Introduction The SUIN SA2100 is a comprehensive and cost effective instrument ideally suited for the electrical trades toolbox and intended to monitor your electrical supply and diagnose Power Quality issues on-site and in real-time. It is battery operated and therefore offers the flexibility of a handheld multi-meter. 1.2.2 Key Features  Safety: CAT III 1000V / CAT IV 600V  Standards: IEC61000-4-30 (2008) S class EN50160 (2007)  Single-phase 2 W / Single-phase 3 W / 3-phase 3 W / 3-phase 4 W  Monitors four (4) voltages and currents  Display: Run Chart, Bar Chart, Vector Graphic, Waveform, Event List, Readings  Harmonics and interharmonics, flicker, transient capture, three-phase unbalance (voltage and current), dips and swells, voltage rapid change, and interruption  LAN interface PC can keep real-time remote communication  Built-in 8G memory card, USB port, LAN port for real-time remote control functionality and data download 1.2.3 Current Sensor Options Description Part Number 5A Clamp-On CT SUC8C-5A 50A Clamp-On CT SUCTC0080 100A Clamp-On CT SUCTC0130 1000A Clamp-On CT SUCTC1535 3000A Flexible Rogowski Coil SUJK-3000A
  • 8. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 8 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 SUC8C-5A SUCTC0080 SUCTC0130 SUCTC1535 SUJK-3000A
  • 9. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 9 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 1.2.4 Voltage Leads
  • 10. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 10 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 1.2.5 Flexible Current Probe 1.2.6 Carry Bag 1.2.7 Kit Items Description Part Number Quantity SA2100 Power Quality Analyser SU2100PQA 1 Program Software for PC (CD) SU2100CD 1 2m voltage cable with 4mm banana plug SU2100VL 5 Alligator Clips SU2100CC 5 External DC Power Adaptor SU2100PA 1 External DC Adaptor SU2100PC 1 Carry Bag SU2100BAG 1 Hang Strap SU2100HS 1 Current Sensors 4 (select option)
  • 11. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 11 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 1.2.8 Specifications Measurement Range Resolution Accuracy Voltage/Current/Frequency Channel 3-phase line input + 1 neutral line input Vrms(dc+ac) 1 ~ 1000Vrms 0.1Vrms ±5% Vpk 1 ~ 1400Vpk 0.1Vpk ±5% V(CF) 1.0 ~ >2.8 0.01 ±5% Arms 1~ 3000A 1A ±1% ± 5digits 1~ 300A 0.1A ±1% ± 5digits Apk 1 ~ 4000Apk 1A ±1% ± 5digits A(CF) 1 ~ 10 0.01 ±5% Frequency 42.5~57.5Hz(50Hz nominal) 0.01Hz ±0.01% 51~69Hz(60Hz nominal) 0.01Hz ±0.01% Dips & Swells Vrms1/2 0 ~ 200% of nominal voltage 0.1Vrms ±1% Arms1/2 1 ~ 3000A 1A ±1% ±5 counts 1 ~ 300A 0.1A ±1% ±5 counts Threshold levels Programmable thresholds in percent of nominal voltage Event detection based upon ½ cycle rms voltages Captures Dips, Swells Interruptions and Rapid Voltage Changes Duration hhh,mm,ss,mmm 0.5 cycle 1 cycle Harmonic Harmonic Order 1 ~ 50 Inter-Harmonic Order 1 ~ 49 Voltage 0.0 ~ 100.0% 0.1% ±0.1% ± nx0.1% Current 0.0 ~ 100.0% 0.1% ±0.1% ± nx0.1% THD 0.0 ~ 100.0% 0.1% ±2.5% DC Relative 0.0 ~ 100.0% 0.1% ±2% Frequency 0 ~ 3500Hz 1Hz 1Hz Phase -360° ~ 0° 1° ± nx1.5° Power And Energy Active Power/Apparent Power/Reactive Power 1.0 ~ 20.00MW 0.1kW ±1.5±10 counts Energy 0.00kWh ~ 200GWh 10Wh ±1.5±10 counts Power Factor 0 ~ 1 0.01 ±0.03 Flicker Pst(1min),Pst,Plt,PF5 0.00 ~ 20.00 0.01 ±5% Unbalance Voltage 0.0 ~ 5.0% 0.1% ±0.5% Current 0.0 ~ 20.0% 0.1% ±1% Voltage Phase Angle -360° ~ 0° 1° ±2digits Current Phase Angle -360° ~ 0° 1° ±5digits Voltage Transient Vpk ±6000Vpk 1V ±15% Vrms 10 ~ 1000Vrms 1V ±2.5% Min. Tested Time 50us
  • 12. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 12 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 Sampling Rate 20kS/s Inrush Current Arms(AC+DC) 0~3000Arms 0.1 ±1% ± 5digits Inrush Duration 6s ~ 32min selectable 10ms ±20ms Logger Recording Parameter, duration time and time interval can be set by user, which can be export on PC Memory 8G Max. recording time 1 year System Monitor Parameters Vrms,Arms,Harmonic Volts,THD Volts,Plt,Vrms1/2,Arms1/2,Vneg,Hz,dips and swells, unbalance Record Time 2h ~ 7days Record Event Number >10000 Limits According EN50160 or customer definable General Characteristics Power AC220V(1±10%), 50Hz(1±5%), ≤10VA Interface USB_HOST, LAN Display 5.6' TFT LCD, 320*240 Battery 7.4V, 4.4Ah, > 7 hours working time Dimension & Weight 262×173×66mm, 1.6kg
  • 13. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 13 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 1.3 ZES Zimmer LMG500 1.3.1 Introduction The ZES Zimmer LMG500 is a 1 to 8 Channel Precision Power Analyser. The LMG500 is best-in-class for measurements of:  Devices, e.g. E-machines, frequency inverters, and transformers;  Installations and associated elements;  Power grids and consumer electrical networks to determine interactions; and  Components, e.g. ferrite cores, semiconductors, and capacitors. Other applications include:  CE compliance tests on devices;  Analysing the feedback of harmonics and flicker (load variations); and  Standby power consumption. 1.3.2 Key Features The most important features of the LMG500 are:  Wide dynamic measuring range from 3V to 1000V/3200Vpeak, 20mA to 32A/120A peak in direct measurement only by a single pair of sockets for each voltage and current input;  Modular with 1 to 8 power measuring channels;  Measuring accuracy at 45 to 65Hz 0.015% of reading plus 0.01% of range;  3MSample/s per channel, absolutely gapless sampling with the evaluation of all sampling values;
  • 14. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 14 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831  Capturing transients and fast signal changes by event triggering in parallel to the ongoing measurement;  Group delay between voltage and current measuring input <3ns as standard to ascertain very precise measurements at low cosj and / or high frequencies;  Harmonics and interharmonics up to 50kHz internally, and up to 1MHz with an external PC;  Flicker, interactions between network and load;  Ergonomic user interface for easy, intuitive use of the power analyser;  Real-time evaluation of the measurements in numeric tables and diagrams; and  Data communication interfaces with high transfer rates (RS232, USB, IEEE488.2, Ethernet). 1.3.3 Device Interface
  • 15. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 15 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 1.3.4 Connections
  • 16. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 16 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 2 Logging Instruments 2.1 Load Logger 2.1.1 Introduction Load Logger measures AC current (load) and is ideal for monitoring loads on circuits and switchboards to record load profiles that can be used to identify slow changing events such as long duration interruptions, outages and derive estimates of usage patterns. Load Logger is also useful as a diagnostic tool to assess load sharing and load balancing on single and three phase systems. Some common monitoring applications include: ac motors and pumps for pool, irrigation, lighting, data centres, air conditioning equipment and switchboards. 2.1.2 Specifications PARAMETER MULTI-CHANNEL Input Channels Current Inputs (RMS) Scalable up to 4 channels - Phases A, B, C and Neutral Temperature Inputs (optional) 2 x PT1000 RTD Communications Serial Data (standard) RS232 (115.2 kbps) Wireless (optional) Bluetooth Logging Logged Data Memory MicroSD Logging Interval Programmable from 1 minute Measurements Current (RMS), Max. Current (RMS), Current Unbalance,
  • 17. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 17 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 Temperature Accuracy ±0.5% (excludes current sensor) System Accuracy ±1% (clamp-on current sensor) Outputs Visual Tools Graphical Interface Data File CSV format Visual Indicator 2 x Status LED Digital 2 x Latched Relays (optional) General Display (optional) LCD: Measurements and Max. Current time Current Sensors Flexible current or clamp-on current probes - Automatic detection Power Supply Non-rechargeable battery with External DC option Battery Life 1 year (@ 5min. non-aggregated logging Safety Category IEC 61010-1,CAT IV 600V defined by CT Physical Dimensions (H x W x L) 55 x 90 x 115 mm Weight 390g (battery included) Material and Colour Polycarbonate, moulded in light grey Operating Temperature -20°C to 85°C Degree of Protection IP65, NEMA 4 2.1.3 Installation The logger can be installed using a mix of clamp-on current and flexible current probes and automatically detects each sensor type. 2.1.4 Software Configuration software included. 2.1.5 Calibration Each Load Logger is factory calibrated. The calibration values are saved in the initial configuration file.
  • 18. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 18 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 3 Remote (Online) Monitoring Systems 3.1 Load Remote Load Remote is a Remote Terminal Unit (RTU) that measures AC current in up to five (5) circuits and facilitates on-line monitoring. All data is transmitted back to a secure database utilising modern communication networks with programmable intervals. The user is provided with a web login and password and able to quickly retrieve, view and download data on-line. HARDWARE INSTALLATION
  • 19. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 19 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 Load Remote is also useful as a diagnostic tool to assess load sharing and load balancing on single and three phase systems. Load Remote is intended for applications requiring long term monitoring and where periodic site visits may not be feasible or access is difficult. Some common monitoring applications include: ac motors and pumps for pool, irrigation, lighting, data centres, air conditioning equipment and switchboards. Digital inputs/outputs and alarm thresholds available for control and condition monitoring applications. This product can be customised to your specific requirements. PARAMETER SPECIFICATION General electrical Rated load current Up to 3000A. Working voltage 600V as defined by current sensor. Power source External 12V DC. Channels AC current (1) AC current, up to five (5) channels or circuits. Temperature (2) Optional: Temperature inputs. Combinations of (1) and (2) totalling five channels. Communications Remote communications Tri-Band UMTS (850MHz/900MHz/2100MHz); Dual-Band GSM/GPRS (900MHz/1800MHz). Device communications RS-232 for programming Data Pitching Programmable transmit interval 1 minute minimum Physical Dimensions (H x W x D) 171 x 121 x 55 mm Material Polycarbonate, moulded in light grey Rating IP65, NEMA4 Operating temperature -20°C to 70°C Load Remote can be packaged into a suitable enclosure to meet your requirements and with various current probes. 3.2 Monitoring Back-Up Generators OmniMetrix is a leader and pioneer in wireless remote monitoring, control and diagnostics for emergency power generator systems. With over 15 years of experience and thousands of monitored generators, OmniMetrix is the proven solution for making emergency power systems more reliable. The OmniMetrix system is currently installed globally on a wide range of critical facilities, including cell towers, grocery stores, medical facilities, data centers and public transportation systems, as well as federal, state and municipal government facilities. As a system that facility maintenance teams have described as vital, we get better information to the right people faster. OmniMetrix’s robust M2M (machine to machine) 24/7 monitoring system increases the reliability of your generators by eliminating 95% of all Fail-to-Start situations. Cost-effective monitors connect to all major brands of generators and are Modbus compatible.
  • 20. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 20 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 3.2.1 G8500 SINGLE GENERATOR SYSTEM
  • 21. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 21 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 3.2.2 G8600 MULTIPLE GENERATOR SYSTEM
  • 22. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 22 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 3.2.3 G8700 MOBILE GENERATOR SYSTEM
  • 23. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 23 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 3.2.4 G8800 RESIDENTIAL GENERATOR SYSTEM
  • 24. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 24 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 4 Current Probes and Sensors 4.1 Flexible Current Sensors PARAMETER 1AFF3000-6 (3000A) (use with PM35) SAF3000_6B (3000A) (use with PM45) Electrical Rated Input Current 3000A 3000A Calibrated Output @ 1000A 50Hz 78mV 78mV Load resistance 4.5KΩ 4.5KΩ Bandwidth 10Hz to 20kHz 10Hz to 20kHz Accuracy (@ 25°C, 50Hz) ± 0.5% of reading ± 0.5% of reading Linearity (10% to 90% of range ± 0.2% of reading ± 0.2% of reading Phase Error (45Hz - 65Hz) ± 1° ± 1° Position Sensitivity ± 2% of reading ± 2% of reading Temperature Coefficient ± 0.05% of reading / °C ± 0.05% of reading / °C External Field (with cable >100mm from the head) ± 0.25% of range ± 0.25% of range Working Voltage 1000V AC or DC 1000V AC or DC General Probe and Cable Material Alcryn 2070 NC double insulated, UL94 V-0 Alcryn 2070 NC double insulated, UL94 V-0 Coupling Material Ultramid A3U Q720, UL94 V-0 Ultramid A3U Q720, UL94 V-0 Probe Cable Diameter 9.9mm (nominal) 9.9mm (nominal) Probe Cable Length 610mm 610mm Probe Cable Conductor Diameter 194mm 194mm Output Cable Length 2m, terminated with Brad Harrison 8A4000-315 2m UL.M12 4P F ST 2M PUR- 0.34 Operating Temperature Range -20°C to +65°C -20°C to +65°C Storage Temperature Range -40°C to +75°C -40°C to +75°C Operating Humidity 15% to 85% (non-condensing) 15% to 85% (non-condensing) Degree of Protection IP65 IP65 Colour Probe: Green RAL6018 Probe: Green RAL6018
  • 25. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 25 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 PARAMETER 1ACF3000-6 (3000A) (use with PM35) 1AF3000-6 (3000A) (use with PM45) Electrical Maximum Measureable Current 100kA at (50/60)Hz 100kA at (50/60)Hz Internal Resistance 30Ω per 400mm 30Ω per 400mm Accuracy ± 1% (Calibrated) ± 1% (Calibrated) Linearity ± 0.2% (Calibrated) ± 0.2% (Calibrated) Output Signal (Sinusoidal) 100mV/KA @ 50Hz 100mV/KA @ 50Hz Frequency Range 20Hz to 5kHz 20Hz to 5kHz Position Sensitivity ± 2% maximum ± 2% maximum Influence of External Field ± 2% maximum ± 2% maximum Temperature Coefficient ± 0.07% per °C ± 0.07% per °C Working Voltage (max.) 1000V at (50/60)Hz 1000V at (50/60)Hz Safety Category (IEC 61010-1) 1000V CAT III / 600V CATIV 1000V CAT III / 600V CATIV High Voltage Withstand 7400VAC (50/60)Hz for 1 minute 7400VAC (50/60)Hz for 1 minute Dimensions Cable length 2m 2m Coil Inside Diameter A 170mm 170mm Coil Outside Diameter B 201mm 201mm Coil Length C 600mm 600mm Cap Coupling cross section D 18mm (min.) 18mm (min.) Cap Coupling cross section E 23mm (max.) 23mm (max.) Coil cross-section F 15.5mm 15.5mm Materials Transducer and cable Thermoplastic RUBBER, flame retardant UL 94 V-O rated Thermoplastic RUBBER, flame retardant UL 94 V-O rated Couplings Polypropylene UL 94 V-O rated Polypropylene UL 94 V-O rated Colour (transducer) Blue Blue Colour (Cable and couplings) Black Black Cable 1000V UL Style 20940; Diameter: 5.5mm - wires 2 x 24AWG 1000V UL Style 20940; Diameter: 5.5mm - wires 2 x 24AWG Shield 85% coil, 100% output cable 85% coil, 100% output cable Environmental Working Temperature -20°C to +70°C -20°C to +70°C Relative Humidity 85% (non-condensing) 85% (non-condensing) Pollution Degree 2 2 Maximum Altitude 2000m 2000m
  • 26. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 26 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 4.2 Clamp on Current Sensors PARAMETER 1AC10 (10A) (use with PM45) 1ACR100S (100A) (use with PM35) 1AC100S (100A) (use with PM45) General electrical Rated Input Current 10A. 100A. 100A. Maximum Input Current 15A. 150A. 150A. Output Signal 440mV @ 10A. 440mV @ 100A. 440mV @ 100A. Burden Included 2.2 Ω (external) Included Accuracy ±1.0% ±1.0% ±1.0% Frequency Range 45Hz - 5000Hz 45Hz - 5000Hz 45Hz - 5000Hz Dielectric Strength 3000V @ 60Hz for 1 minute 3000V @ 60Hz for 1 minute 3000V @ 60Hz for 1 minute Working Voltage Bare conductor: 30V; Insulated conductor: 600V Bare conductor: 30V; Insulated conductor: 600V Bare conductor: 30V; Insulated conductor: 600V Physical Dimensions (H x W x L) (90.5 x 41.2 x 23.8) mm (90.5 x 41.2 x 23.8) mm (90.5 x 41.2 x 23.8) mm Jaw Aperture (14.3 x 15.9) mm (14.3 x 15.9) mm (14.3 x 15.9) mm Weight 113 grams (excluding lead and connector) 113 grams (excluding lead and connector) 113 grams (excluding lead and connector) Colour Grey / light grey Grey / light grey Grey / light grey Safety Class Class III per IEC 61010- 1 Class III per IEC 61010- 1 Class III per IEC 61010- 1 Operating temperature -20°C to 50°C -20°C to 50°C -20°C to 50°C Relative Humidity 85% (non-condensing) 85% (non-condensing) 85% (non-condensing)
  • 27. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 27 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 PARAMETER 1ACR100 (100A) (use with PM35) 1ACR500 (500A) (use with PM35) 1ASC500 (500A) (use with PM45) General electrical Rated Input Current 100A 500A 500A Maximum Input Current 120A 650A 650A Output Signal 440mV @ 100A. 440mV @ 500A. 440mV @ 500A. Burden Included Included Included Accuracy (Ratio Error) Better than ±1.0% Maximum Error (Ratio Error) 1% accuracy from 20% to 125% of rated current 1.5% @ 5% and 0.5% @110% of rated current 1.5% @ 5% and 0.5% @110% of rated current Phase Error <0.36 degrees at rated current Maximum Burden 15VA 15VA 15VA Accuracy Class 0.5M AS1675 0.5M AS1675 0.5M AS1675 Double Insulation 300V AC RMS 300V AC RMS 300V AC RMS Frequency Range 40Hz - 5000Hz 5Hz - 5000Hz; 0.5% R.E. (40-85) Hz 5Hz - 5000Hz; 0.5% R.E. (40-85) Hz Dielectric Strength 3000V @ 60Hz for 1 minute 3000V @ 60Hz for 1 minute 3000V @ 60Hz for 1 minute Working Voltage 650V 650V 650V Physical Dimensions (H x W x L) (99 x 210 x 60) mm (99 x 210 x 60) mm (99 x 210 x 60) mm Jaw Aperture 52 mm 52mm 52mm Weight 750 grams (excluding lead and connector) 750 grams (excluding lead and connector) 750 grams (excluding lead and connector) Encapsulation / Colour Fully insulated / Black Fully insulated / Black Fully insulated / Black Safety Class CAT III per IEC 61010- 1 CAT III per IEC 61010- 1 CAT IV per IEC 61010-1 Operating temperature -10°C to 50°C -10°C to 50°C -10°C to 50°C
  • 28. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 28 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 4.3 Miniature Split-Core Current Transformers 4.3.1 Key Features and General Specifications  Lightweight, safe (includes internal burden), quick and easy installation - no power line disruption required.  Rated primary current: up to 400Aac  Rated secondary: 0.333Vac at rated primary Current  Class (accuracy): 0.5, 1.0, 3.0 [IEC 60044-1]  Rated security coefficient: FS<5  Case material: Nylon resin UL flame retardant Rating 94-VO  Highest voltage for equipment Um (rms): 720Vac  Rated power-frequency withstand voltage (rms): 3000Vac  Frequency range: (50/60) Hz  Operating temperature: 15 to 60  RoHS compliant  CE approved  ETL approved, CAT II 600V  Leads: 0.8 Foot (240mm), UL 1015, twisted pair, 0.34m2 (22AWG) 4.3.2 Range Description Part Number Input: 1-25A;Output: 0.333V@ 25A; Class: 1.0; Cable diameter: 10.2mm CTSA010 Input: 5-100A;Output: 0.333V@ 100A; Class: 0.5; Cable diameter: 16.2mm CTSA016 Input: 5-200A;Output: 0.333V@ 200A; Class: 0.5; Cable diameter: 24.2mm CTSA024 Input: 5-400A;Output: 0.333V@ 400A; Class: 0.5; Cable diameter: 35.2mm CTSA035
  • 29. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 29 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 4.4 Substation Current Transformer Converters 4.4.1 Introduction CK1: 1 Amp Substation CT Converter CK5: 5 Amp Substation CT Converter The CK1 or CK5 Powermonic Current Transformer (CT) Converter is a three phase device that transforms the standard 1A or 5A secondary current from a CT to a 200 mA output current suitable for direct connection to a Powermonic CT input. Internal protection is provided to enable the output leads to be disconnected from the Powermonic without affecting the CT secondary circuits. The units are designed for high accuracy and therefore lend themselves for Metering and Power Quality applications. 4.4.2 Specifications PARAMETER CK1 (1A to 200mA) CK5 (5A to 200mA) Electrical Rated Input Current 1A 5A Rated Output Current 200mA 200mA Accuracy Class 0.5M (AS1675) 0.5M (AS1675) Working Voltage 1000V AC or DC 1000V AC or DC General Input Connections Red, White and Blue banana sockets Red, White and Blue banana sockets Output Connections Colour coded 1.8m leads with 4 pin connectors to suite PM20, PM30, PM30+, PM40 Colour coded 1.8m leads with 4 pin connectors to suite PM20, PM30, PM30+, PM40 Enclosure Light grey polycarbonate Light grey polycarbonate Weight 4.4kg 4.4kg Dimensions (W x L x D) (140 x 230 x 100) mm (140 x 230 x 100) mm Including glands and sockets (140 x 280 x 100) mm (140 x 280 x 100) mm
  • 30. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 30 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 5 Instrument Current Transformers Australian Standard 60044.1-2007 Instrument transformers Part 1: Current transformers (IEC 60044-1 Ed.1.2 (2003) MOD).
  • 31. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 31 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 5.1 Metering 5.1.1 Measuring - PVC The SES range of PVC tape insulated metering CTs are designed and manufactured to cater for wide range of applications. They are tested to IEC 60044-1 2003-02 and are certified to ASTA and CE mark Certified to UL. The standard rated secondary current is 5A. Ratio Class 3 5VA Class 1 15VA Class 0.5 15VA ID OD HT ID OD HT ID OD HT 60/5 A 28 70 28 28 70 102 100/5 A 34 74 23 34 80 72 34 80 185 150/5 A 34 74 23 34 80 48 34 100 72 200/5 A 45 80 28 34 80 33 34 80 92 250/5 A 45 80 28 45 80 38 45 80 70 300/5 A 45 80 28 45 80 38 45 80 60 400/5 A 60 96 23 60 96 23 60 96 40 500/5 A 65 100 23 68 100 23 65 100 30 600/5 A 65 100 23 68 100 23 85 100 30 800/5 A 85 122 23 85 122 28 85 122 40 1000/5 A 85 122 23 85 122 28 90 122 30 1200/5 A 90 135 23 90 135 28 90 135 33 1600/5 A 90 135 23 90 135 28 122 135 33 2000/5 A 123 162 23 123 162 23 122 165 33 2500/5 A 123 162 23 123 162 23 122 165 35 3000/5 A 123 162 23 123 162 23 140 165 35 3500/5 A 143 185 28 143 185 28 140 190 30 4000/5 A 143 185 28 143 185 28 140 190 30 5000/5 A 143 185 28 143 185 28 140 190 35
  • 32. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 32 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 5.1.2 Measuring - MBQ Series MBQ series current transformers are ideally designed for bus bar mounting and find applications in measurement, test and control of electrical equipment. The MBQ current transformer is housed into a case of PPO flame retardant material. Type A B C D MBQ 60/30 75 60 30 30 x 10 MBQ 60/40 75 60 30 40 x 10 MBQ 95/50 105 95 40 60 x 30 MBQ 95/70 105 95 40 60 x 10 MBQ 130/100 167 129 60 100 x 55 Type MBQ 60/30 MBQ 60/40 MBQ 95/50 MBQ 95/70 MBQ 130/100 Ratio Burden (VA) Burden (VA) Burden (VA) Burden (VA) Burden (VA) Class 1 Class 0.5 Class 1 Class 0.5 Class 1 Class 0.5 Class 1 Class 0.5 Class 1 Class 0.5 100/5 A 2.5 1.5 125/5 A 2.5 1.5 150/5 A 2.5 2.5 2.5 1.5 200/5 A 5 5 2.5 1.5 2.5 1.5 250/5 A 5 5 5 2.5 2.5 1.5 300/5 A 5 5 5 2.5 2.5 1.5 5 2.5 400/5 A 5 5 5 2.5 5 2.5 10 5 500/5 A 10 5 5 2.5 10 5 15 10 600/5 A 10 5 10 5 10 5 15 10 5 2.5 750/5 A 10 5 10 5 15 10 10 5 800/5 A 10 5 10 5 15 10 10 5 1000/5 A 15 10 15 15 15 10 1200/5 A 15 10 15 15 15 10 1250/5 A 15 10 15 15 15 10 1500/5 A 15 15 15 15 15 15 1600/5 A 15 15 15 15 15 15 2000/5 A 15 15 15 15 2500/5 A 15 15 3000/5 A 15 15
  • 33. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 33 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 5.1.3 Measuring - MSQ Series MSQ series current transformers are ideally designed for bus bar mounting and find applications in measurement, test and control of electrical equipment. The MSQ current transformer is housed into a case of PPO flame retardant material. FEATURES:  Flame retardant  High mechanical strength  High dielectric strength  Transparent sealable terminal cover  Base or Bus bar mounting Type A B C D MSQ 30 98 75 43 30 x 10 MSQ 40 98 75 43 40 x 10 MSQ 60 127 101 44 60 x 20 MSQ 85 164 128 42 80 x 30 MSQ 100 156 144 44 100 x 10 MSQ 125 220 190 42 125 x 58
  • 34. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 34 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 TypeClass 1Class 0.5Class 1Class 0.5Class 1Class 0.5Class 1Class 0.5Class 1Class 0.5Class 1Class 0.5100/5 A52.51.51.5125/5 A52.51.51.5150/5 A552.51.5200/5 A10552.5250/5 A101052.52.51.5300/5 A151052.552.5400/5 A15151051057.55500/5 A15151051057.55600/5 A151515101051057.55750/5 A15101051057.55800/5 A151015101051051000/5 A1510151015101051200/5 A15151510151015101250/5 A15151510151015101500/5 A15151515151515151600/5 A15151515151515152000/5 A1515151515152500/5 A151515153000/5 A151515154000/5 A15155000/5 A15156000/5 A1515Burden (VA) MSQ 125Burden (VA) MSQ 30MSQ 40MSQ 60MSQ 85MSQ 100RatioBurden (VA)Burden (VA)Burden (VA)Burden (VA)
  • 35. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 35 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 5.1.4 Measuring - Tape Insulated Ring Type - KTM Series Part Number Ratio Burden (VA) Class ID OD HT KTM1R30PD 30/5 A 2.5 5 30 75 70 KTM1R40PD 40/5 A 2.5 5 30 75 55 KTM1R50PD 50/5 A 2.5 5 30 75 45 KTM1R50QD 50/5 A 5 5 30 75 75 KTM1R75PD 75/5 A 2.5 5 30 75 35 KTM1R75QD 75/5 A 5 5 30 80 60 KTM1R100QB 100/5 A 5 5 30 80 70 KTM1R100RB 100/5 A 7.5 1 30 75 90 KTM1R125QB 125/5 A 5 1 30 80 60 KTM1R125RB 125/5 A 7.5 1 30 75 65 KTM1R150QB 150/5 A 5 1 30 80 40 KTM1R150TB 150/5 A 7.5 1 30 80 80 KTM1R150QA 150/5 A 15 0.5 30 75 75 KTM1R200QB 200/5 A 5 1 30 75 30 KTM1R200QA 200/5 A 5 0.5 30 75 45 KTM1R200TB 200/5 A 15 1 30 75 55 Part Number Ratio Burden (VA) Class ID OD HT KTM2R100QB 100/5 A 5 1 45 95 100 KTM2R125QB 125/5 A 5 1 45 90 55 KTM2R150QB 150/5 A 5 1 45 90 45 KTM2R150QA 150/5 A 5 0.5 45 95 90 KTM2R200QB 200/5 A 5 1 45 90 30 KTM2R200QA 200/5 A 5 0.5 45 90 60 KTM2R200TB 200/5 A 15 1 45 90 60 KTM2R250QB 250/5 A 5 1 45 90 30 KTM2R250QA 250/5 A 5 0.5 45 95 40 KTM2R250TB 250/5 A 15 1 45 90 50 KTM2R300QB 300/5 A 5 1 45 90 25 KTM2R300QA 300/5 A 5 0.5 45 90 30
  • 36. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 36 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 KTM2R300TB 300/5 A 15 1 45 90 45 KTM2R400QB 400/5 A 5 1 45 90 25 KTM2R400QA 400/5 A 5 0.5 45 90 25 KTM2R400TB 400/5 A 15 1 45 90 35 KTM2R400TA 400/5 A 15 0.5 45 90 45 Part Number Ratio Burden (VA) Class ID OD HT KTM3R300QB 300/5 A 5 1 55 95 35 KTM3R300QA 300/5 A 5 0.5 55 95 45 KTM3R300TB 300/5 A 15 1 55 100 50 KTM3R400QB 400/5 A 5 1 55 100 25 KTM3R400QA 400/5 A 5 0.5 55 105 35 KTM3R400TB 400/5 A 15 1 55 100 45 KTM3R400TA 400/5 A 15 0.5 55 120 40 KTM3R500QB 500/5 A 5 1 55 100 25 KTM3R500QA 500/5 A 5 0.5 55 105 30 KTM3R500TB/TA 500/5 A 15 1/0.5 55 100 40 KTM3R600QB/QA 600/5 A 5 1/0.5 55 105 30 KTM3R600TB/TA 600/5 A 15 1/0.5 55 105 40 Part Number Ratio Burden (VA) Class ID OD HT KTM4R600QB/QA 600/5 A 5 1/0.5 70 120 30 KTM4R600TB/TA 600/5 A 15 1/0.5 70 120 40 KTM4R800QB 800/5 A 5 1 70 120 30 KTM4R800QA 800/5 A 5 0.5 70 110 30 KTM4R800TB/TA 800/5 A 15 1/0.5 70 120 35 KTM4R1000QB/QA 1000/5 A 5 1/0.5 70 120 30 KTM4R1000TB/TA 1000/5 A 15 1/0.5 70 120 35 KTM4R1200/QA/ 1200/5 A 5/15 1/0.5 70 120 30 Part Number Ratio Burden (VA) Class ID OD HT KTM5R800QB/QA 800/5 A 5 1/0.5 85 125 30 KTM5R800TB/TA 800/5 A 15 1/0.5 85 140 35 KTM5R1000QB/QA 1000/5 A 5 1/0.5 85 125 30 KTM5R1000TB/TA 1000/5 A 15 1/0.5 85 140 30 KTM5R1200QA 1200/5 A 5 0.5 85 140 30 KTM5R1200TB/TA 1200/5 A 15 1/0.5 85 140 30 KTM5R1600QB/QA/TB 1600/5 A 5/15 1/0.5 85 140 30 Part Number Ratio Burden (VA) Class ID OD HT KTM6R1000QB/QA 1000/5 A 5 1/0.5 115 155 30
  • 37. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 37 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 KTM6R1000TB/TA 1000/5 A 15 1/0.5 115 170 35 KTM6R1200QB/QA 1200/5 A 5 1/0.5 115 155 30 KTM6R1200TB/TA 1200/5 A 15 1/0.5 115 170 30 KTM6R1600QB/ 1600/5 A 5/15 1/0.5 115 170 30 KTM6R2000TB/TA 2000/5 A 15 1/0.5 115 170 30 KTM6R2500TB/TA 2500/5 A 15 1/0.5 115 185 35 KTM6R3000TB/TA 3000/5 A 15 1/0.5 115 185 35 KTM6R3500TB/TA 3500/5 A 15 1/0.5 115 185 35 Part Number Ratio Burden (VA) Class ID OD HT KTM7R3000TB/TA 3000/5 A 15 1/0.5/0.2 135 205 35 KTM7R3500TB/TA 3500/5 A 15 1/0.5/0.2 135 205 35 KTM7R4000TB/TA 4000/5 A 15 1/0.5/0.2 135 205 35 KTM7R4500TB/TA 4500/5 A 15 1/0.5/0.2 135 210 40 KTM7R5000TB/TA 5000/5 A 15 1/0.5/0.2 135 210 40 KTM8R4000TB/TA 4000/5 A 15 1/0.5/0.2 170 240 35 KTM8R4500TB/TA 4500/5 A 15 1/0.5/0.2 170 240 35 KTM8R5000TB/TA 5000/5 A 15 1/0.5/0.2 170 240 35
  • 38. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 38 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 5.1.5 Measuring - Resin Cast Ring Type - KRM Series Part Number Ratio Burden (VA) Class ID OD HT KRM1R30PD 30/5 A 2.5 5 30 80 80 KRM1R40PD 40/5 A 2.5 5 30 95 40 KRM1R50PD 50/5 A 2.5 5 30 75 65 KRM1R50QD 50/5 A 5 5 30 80 80 KRM1R75PD 75/5 A 2.5 5 30 95 40 KRM1R75QD 75/5 A 5 5 30 75 65 KRM1R100QB 100/5 A 5 1 30 80 80 KRM1R100RB 100/5 A 7.5 1 30 90 135 KRM1R125QB 125/5 A 5 1 30 75 65 KRM1R125RB 125/5 A 7.5 1 30 80 80 KRM1R150QB 150/5 A 5 1 30 75 65 KRM1R150QA 150/5 A 5 0.5 30 80 80 KRM1R200QB 200/5 A 5 1 30 75 40 KRM1R200QA 200/5 A 5 0.5 30 75 65 KRM1R200TB 200/5 A 15 1 30 80 70 Part Number Ratio Burden (VA) Class ID OD HT KRM2R100QB 100/5 A 5 1 45 100 100 KRM2R125QB 125/5 A 5 1 45 98 60 KRM2R150QB 150/5 A 5 1 45 100 45 KRM2R150QA 150/5 A 5 0.5 45 100 100 KRM2R200QB 200/5 A 5 1 45 95 40 KRM2R200QA 200/5 A 5 0.5 45 98 60 KRM2R200TB 200/5 A 15 1 45 98 60 KRM2R250QB 250/5 A 5 1 45 95 40 KRM2R250QA 250/5 A 5 0.5 45 95 40 KRM2R250TB 250/5 A 15 1 45 100 45 KRM2R300QB 300/5 A 5 1 45 95 40 KRM2R300QA 300/5 A 5 0.5 45 95 40 KRM2R300TB 300/5 A 15 1 45 100 45
  • 39. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 39 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 KRM2R400QB 400/5 A 5 1 45 95 40 KRM2R400QA 400/5 A 5 0.5 45 95 40 KRM2R400TB 400/5 A 15 1 45 95 40 KRM2R400TA 400/5 A 15 0.5 45 95 40 Part Number Ratio Burden (VA) Class ID OD HT KRM3R300QB 300/5 A 5 1 55 95 40 KRM3R300QA 300/5 A 5 0.5 55 100 45 KRM3R400QB/QA 400/5 A 5 1/0.5 55 95 40 KRM3R400TB 400/5 A 15 1 55 98 60 KRM3R300QB 300/5 A 5 1 55 95 40 KRM3R300QA 300/5 A 5 0.5 55 100 45 KRM3R400QB/QA 400/5 A 5 1/0.5 55 95 40 KRM3R400TB 400/5 A 15 1 55 98 60 KRM3R400TA 400/5 A 15 0.5 55 115 35 KRM3R500QB/QA 500/5 A 5/15 1/0.5 55 95 40 KRM3R600QB/QA 600/5 A 5/15 1/0.5 55 100 45 Part Number Ratio Burden (VA) Class ID OD HT KRM4R600QB/QA 600/5 A 5 1/0.5 70 115 35 KRM4R600TB 600/5 A 15 1 70 115 35 KRM4R600TA 600/5 A 15 0.5 70 140 25 KRM4R800QB/QA 800/5 A 5/15 1/0.5 70 115 35 KRM4R1000QB/QA 1000/5 A 5 1/0.5 70 115 35 KRM4R1000TB/TA 1000/5 A 15 1/0.5 70 140 25 KRM4R1200QB/QA 1200/5 A 5/15 1/0.5 70 115 35 Part Number Ratio Burden (VA) Class ID OD HT KRM5R800QB/QA 800/5 A 5/15 1/0.5 85 140 25 KRM5R1000QB/QA 1000/5 A 5/15 1/0.5 85 140 25 KRM5R1200QB/QA 1200/5 A 5/15 1/0.5 85 140 25 KRM5R1600QB/QA/ 1600/5 A 5/15 1/0.5 85 145 35 KRM6R1000QB/QA 1000/5 A 5/15 1/0.5 115 175 30
  • 40. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 40 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 5.1.6 Measuring - Resin Cast Ring Type - KSM Series Part Number Ratio Burden (VA) Class ID OD HT KSM1R30PD 30/5 A 2.5 5 30 85 85 KSM1R40PD 40/5 A 2.5 5 30 90 40 KSM1R50QD 50/5 A 5 5 30 85 85 KSM1R100QB 100/5 A 5 1 30 85 85 KSM1R150QD 150/5 A 5 5 30 90 40 KSM1R150TB 150/5 A 15 1 30 85 85 KSM1R200QB 200/5 A 5 1 30 90 40 KSM1R200TB 200/5 A 15 1 30 80 60 Part Number Ratio Burden (VA) Class ID OD HT KSM2R150QD 150/5 A 5 5 45 90 40 KSM2R150QB 150/5 A 5 1 45 100 40 KSM2R200QB 200/5 A 5 1 45 90 40 KSM2R200TB 200/5 A 15 1 45 100 65 KSM2R250QB 250/5 A 5 1 45 90 40 KSM2R250TB 250/5 A 15 1 45 100 65 KSM2R300QB 300/5 A 5 1 45 90 40 KSM2R300TB 300/5 A 15 1 45 100 40 KSM2R300SA 300/5 A 10 0.5 45 100 40 KSM2R400QB 400/5 A 5 1 45 90 45 KSM2R400TB 400/5 A 15 1 45 100 40 KSM2R400SA 400/5 A 10 0.5 45 90 45
  • 41. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 41 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 Part Number Ratio Burden (VA) Class ID OD HT KSM3R300TB 300/5 A 15 1 55 100 65 KSM3R300SA 300/5 A 10 0.5 55 100 65 KSM3R400TB 400/5 A 15 1 55 120 40 KSM3R400SA 400/5 A 10 0.5 55 100 40 KSM3R500TB 500/5 A 15 1 55 100 45 KSM3R500SA 500/5 A 10 0.5 55 100 40 KSM3R600TB 600/5 A 15 1 55 100 40 KSM3R600SA 600/5 A 10 0.5 55 100 40 Part Number Ratio Burden (VA) Class ID OD HT KSM4R800TA 800/5 A 15 0.5 70 120 40 KSM4R1000TA 1000/5 A 15 0.5 70 120 40 KSM4R1200TA 1200/5 A 15 0.5 70 120 40 Part Number Ratio Burden (VA) Class ID OD HT KSM5R800TA 800/5 A 15 0.5 85 145 40 KSM5R1000TA 1000/5 A 15 0.5 85 145 40 KSM5R1200TA 1200/5 A 15 0.5 85 145 40 KSM5R1200TE 1200/5 A 15 0.2 85 145 40 KSM5R1600TE 1600/5 A 15 0.2 85 145 40 Part Number Ratio Burden (VA) Class ID OD HT KSM6R1000TA 1000/5 A 15 0.5 115 175 40 KSM6R1000TE 1000/5 A 15 0.2 115 175 40 KSM6R1200TA 1200/5 A 15 0.5 115 175 40 KSM6R1200QE 1200/5 A 5 0.2 115 175 40 KSM6R1200TE 1200/5 A 15 0.2 115 175 40 KSM6R1600TA 1600/5 A 15 0.5 115 175 40 KSM6R1600TE 1600/5 A 15 0.2 115 175 40 KSM6R2000TA 2000/5 A 15 0.5 115 175 40 KSM6R2000SE 2000/5 A 10 0.2 115 175 40 KSM6R2000TE 2000/5 A 15 0.2 115 175 40 KSM6R2500TE 2500/5 A 15 0.2 115 175 40 KSM6R3000TE 3000/5 A 15 0.2 115 175 40 KSM6R3500TE 3500/5 A 15 0.2 115 175 40
  • 42. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 42 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 5.2 Protection 5.2.1 Protection - PVC The SES range of PVC tape insulated Protection CTs are designed and manufactured to cater for wide range of applications. They are tested to IEC 60044-1 2003-02 and are certified to ASTA and CE mark Certified to UL. The standard rated secondary current is 5A. Ratio Class 10P5 15VA Class 10P10 15VA Class 5P10 15VA ID OD HT ID OD HT ID OD HT 60/5 A 34 100 148 25 150 155 25 150 165 100/5 A 34 100 98 34 100 168 34 100 180 150/5 A 34 100 68 34 100 108 34 100 130 200/5 A 34 100 68 34 100 88 34 100 110 250/5 A 45 96 78 45 96 108 45 96 110 300/5 A 45 96 68 45 96 108 45 96 120 400/5 A 60 100 68 60 100 108 45 96 100 500/5 A 60 100 58 60 100 93 60 100 110 600/5 A 65 100 58 68 110 78 68 110 88 800/5 A 85 120 48 85 120 73 85 120 88 1000/5 A 82 123 65 82 123 80 1200/5 A 90 135 65 90 135 80 1600/5 A 90 135 55 90 135 70 2000/5 A 125 178 43 125 178 43 2500/5 A 125 178 35 125 178 35 3000/5 A 120 178 35 120 178 35 3500/5 A 140 200 35 140 200 35 4000/5 A 140 200 35 140 200 35 5000/5 A 140 200 35 140 200 35
  • 43. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 43 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 5.2.2 Protection - Tape Insulated Ring Type - KTP Series Part Number Ratio Burden (VA) Class ID OD HT Part Number Class OD HT KTP1R100QL5 100/5 A 5 10P5 30 80 105 KTP1R100QM10 5P10 95 130 KTP1R100RL5 100/5 A 7.5 10P5 30 95 100 KTP1R100RM10 5P10 120 115 KTP1R100SL5 100/5 A 10 10P5 30 95 125 KTP1R100SM10 5P10 120 150 KTP1R150QM5 150/5 A 5 5P5 30 80 75 KTP1R150QM10 5P10 95 95 KTP1R150RL10 150/5 A 7.5 10P10 30 95 135 KTP1R150RM10 5P10 95 135 Part Number Ratio Burden (VA) Class ID OD HT Part Number Class OD HT KRP2R100QL5 100/5 A 5 10P5 45 100 100 KTP2R100QM10 5P10 110 115 KTP2R100SL5 100/5 A 10 10P5 45 105 125 KTP2R100SM10 5P10 140 135 KTP2R150RL10 150/5 A 7.5 10P10 45 110 115 KTP2R150RM10 5P10 110 115 KTP2R200QM10 200/5 A 5 5P10 45 110 70 KTP2R200QM20 5P20 110 120 KTP2R250QM10 250/5 A 5 5P10 45 110 60 KTP2R250QM20 5P20 110 115 Part Number Ratio Burden (VA) Class ID OD HT Part Number Class OD HT KTP3R300TM10 300/5 A 15 5P10 55 140 80 KTP3R300TM5 5P5 130 60 KTP3R400TM10 400/5 A 15 5P10 55 140 70 KTP3R400TM20 5P20 130 140 KTP3R500TM10 500/5 A 15 5P10 55 130 65 KTP3R500TM20 5P20 140 110 KTP3R600TM10 600/5 A 15 5P10 55 135 65 KTP3R600TM20 5P20 145 100 Part Number Ratio Burden (VA) Class ID OD HT Part Number Class OD HT KTP4R600TM10 600/5 A 15 5P10 70 145 60 KTP4R600TM20 5P20 145 110 KTP4R800TM10 800/5 A 15 5P10 70 150 55 KTP4R800TM20 5P20 150 95 KTP4R1000TM10 1000/5 A 15 5P10 70 150 50 KTP4R1000TM20 5P20 150 80 KTP4R1200TM10 1200/5 A 15 5P10 70 150 50 KTP4R1200TM20 5P20 150 75 Part Number Ratio Burden (VA) Class ID OD HT Part Number Class OD HT KTP5R800TM10 800/5 A 15 5P10 85 170 55 KTP5R800TM20 5P20 180 80
  • 44. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 44 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 KTP5R1000TM10 1000/5 A 15 5P10 85 170 50 KTP5R1000TM20 5P20 170 80 KTP5R1200TM10 1200/5 A 15 5P10 85 170 50 KTP5R1200TM20 5P20 180 65 KTP5R1600TM10 1600/5 A 15 5P10 85 170 45 KTP5R1600TM20 5P20 180 55 Part Number Ratio Burden (VA) Class ID OD HT Part Number Class OD HT KTP6R2000TM10 2000/5 A 15 5P10 115 190 50 KTP6R2000TM20 5P20 195 65 KTP6R2500TM10 2500/5 A 15 5P10 115 190 45 KTP6R2500TM20 5P20 195 60 KTP6R3000TM10 3000/5 A 15 5P10 115 190 45 KTP6R3000TM20 5P20 200 60 KTP6R3500TM10 3500/5 A 15 5P10 115 195 50 KTP6R3500TM20 5P20 215 50
  • 45. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 45 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 5.2.3 Protection - Resin Cast Ring Type - KRP Series Part Number Ratio Burden (VA) Class ID OD HT Part Number Class OD HT KRP1R100QL5 100/5 A 5 10P5 30 100 75 KRP1R100QM10 5P10 90 135 KRP1R100SL5 100/5 A 10 10P5 30 90 135 KRP1R100SM10 5P10 120 145 KRP1R150QM5 150/5 A 5 5P5 30 80 70 KRP1R150QM10 5P10 100 100 KRP1R150RL10 150/5 A 7.5 10P10 30 90 135 KRP1R150RM10 5P10 90 135 Part Number Ratio Burden (VA) Class ID OD HT Part Number Class OD HT KRP2R100QL5 100/5 A 5 10P5 45 100 100 KRP2R100QM10 5P10 105 135 KRP2R100SL5 100/5 A 10 10P5 45 105 120 KRP2R100SM10 5P10 155 130 KRP2R200SM10 200/5 A 10 5P20 45 105 135 KRP2R200SM20 5P20 145 160 KRP2R250SM10 250/5 A 10 5P20 45 105 120 KRP2R250SM20 5P20 155 110 KRP2R300TM10 300/5 A 15 5P20 45 105 135 KRP2R300TM5 5P5 100 100 KRP2R400TM10 400/5 A 15 5P20 45 105 120 KRP2R400TM20 5P20 145 100 Part Number Ratio Burden (VA) Class ID OD HT Part Number Class OD HT KRP3R400TM10 400/5 A 15 5P20 55 140 70 KRP3R400TM20 5P20 155 130 KRP3R450TM10 450/5 A 15 5P20 55 120 90 KRP3R450TM20 5P20 155 110 KRP3R500TM10 500/5 A 15 5P20 55 140 70 KRP3R500TM20 5P20 145 100 KRP3R600TM10 600/5 A 15 5P20 55 140 70 KRP3R600TM20 5P20 145 100 Part Number Ratio Burden (VA) Class ID OD HT Part Number Class OD HT KRP4R600TM10 600/5 A 15 5P20 70 140 70 KRP4R600TM20 5P20 155 110 KRP4R800TM10 800/5 A 15 5P20 70 140 70 KRP4R800TM20 5P20 145 100 KRP4R1000TM10 1000/5 A 15 5P20 70 140 70 KRP4R1000TM20 5P20 155 90 KRP4R1200TM10 1200/5 A 15 5P20 70 140 70 KRP4R1200TM20 5P20 155 90 Part Number Ratio Burden (VA) Class ID OD HT Part Number Class OD HT
  • 46. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 46 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 KRP5R800TM10 800/5 A 15 5P20 85 165 60 KRP5R800TM20 5P20 190 75 KRP5R1000TM10 1000/5 A 15 5P20 85 165 60 KRP5R1000TM20 5P20 190 75 KRP5R1200TM10 1200/5 A 15 5P20 85 165 60 KRP5R1200TM20 5P20 190 75 KRP5R1600TM10 1600/5 A 15 5P20 85 165 60 KRP5R1600TM20 5P20 190 75 Part Number Ratio Burden (VA) Class ID OD HT Part Number Class OD HT KRP6R1000TM10 1000/5 A 15 5P20 115 190 75 KRP6R1000TM20 5P20 190 90 KRP6R1200TM10 1200/5 A 15 5P20 115 190 75 KRP6R1200TM20 5P20 190 75 KRP6R1600TM10 1600/5 A 15 5P20 115 190 75 KRP6R1600TM20 5P20 190 75 KRP6R2000TM10 2000/5 A 15 5P20 115 190 35 KRP6R2000TM20 5P20 190 75 KRP6R2500TM10 2500/5 A 15 5P20 115 190 75 KRP6R2500TM20 5P20 190 75 KRP6R3000TM10 3000/5 A 15 5P20 115 190 75 KRP6R3000TM20 5P20 190 75 KRP6R3500TM10 3500/5 A 15 5P20 115 190 75 KRP6R3500TM20 5P20 205 115
  • 47. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 47 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 5.2.4 Protection - Resin Cast Ring Type - KSP Series Part Number Ratio Burden (VA) Class ID OD HT KSP1R100QL5 100/5 A 5 10P5 30 100 65 KSP1R100SL5 100/5 A 10 10P5 30 125 75 KSP1R150RL10 150/5 A 7.5 10P10 30 125 75 KSP2R100SL5 100/5 A 10 10P5 45 140 75 KSP2R150RL10 150/5 A 7.5 10P10 45 140 75 KSP3R600TM10 600/5 A 15 5P10 55 125 75 KSP4R600TM10 600/5 A 15 5P10 70 140 75 KSP4R800TM10 800/5 A 15 5P10 70 140 75 KSP4R1000TM10 1000/5 A 15 5P10 70 175 40 KSP4R1200TM10 1200/5 A 15 5P10 70 140 75 KSP5R800TM10 800/5 A 15 5P10 85 175 40 KSP5R1200TM10 1200/5 A 15 5P10 85 175 40 KSP5R1600TM10 1600/5 A 15 5P10 85 175 40 KSP6R1000TM10 1000/5 A 15 5P10 115 190 85 KSP6R1200TM10 1200/5 A 15 5P10 115 190 85 KSP6R1600TM10 1600/5 A 15 5P10 115 190 85 KSP6R2000TM10 2000/5 A 15 5P10 115 190 85 KSP6R2500TM10 2500/5 A 15 5P10 115 190 85 KSP6R3000TM10 3000/5 A 15 5P10 115 190 85
  • 48. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 48 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 5.3 Special Purpose 5.3.1 Summation Current Transformer When the current in a number of feeders need not be individually metered but summated to a single meter or instrument, a summation current transformer can be used. In consumer installation, where there is more than one feeder, it is more economical to use summation metering and for this purpose, summation Current Transformer (CT) is required. The summation CT consists of two or more primary windings which are connected to the feeders to be summated, and a single secondary winding which feeds a current proportional to the summated primary current. A typical ratio would be 5 + 5 + 5 / 5A, which means that three primary feeders of 5 Amps are to be summated to a single 5 Amps meter. We can custom-design to your specific requirements. 5.3.2 Interposing Current Transformer Interposing types can be used to modify the secondary current from an existing line CT. This is useful for modifying secondary currents without replacing the line CTs. The main function of an interposing CT is to balance the currents supplied to the relay where there would otherwise be an imbalance due to the ratios of the main CTs. Interposing CTs are equipped with a wide range of taps that can be selected by the user to achieve the balance required.
  • 49. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 49 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 As the name suggests, an interposing CT is installed between the secondary winding of the main CT and the relay. They can be used on the primary side or secondary side of the power transformer being protected, or both. Interposing CTs also provide a convenient method of establishing a delta connection for the elimination of zero sequence currents where this is necessary. 5.3.3 Core Balance Current Transformer Core balance current transformers are intended for providing a very sensitive method of earth leakage protection on three-phase electrical systems with suitable relays. Cables of all phases pass through the inner diameter of the transformer and there is no output under no-fault conditions. In the event of an earth-fault a non-zero current exist and induces a changing magnetic field within the core, which in turn generates a secondary voltage which operates a relay (via burden). We can optimally custom-design to your specific requirements based on relay types and settings, and the required primary operating current.
  • 50. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 50 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 6 Medium Voltage Products 6.1 Monitoring Products 6.1.1 Cable Mounted Sensor The LIQ60 is an intelligent transmission and distribution overhead line monitoring system and can provide:  Continuous monitoring and capture of critical performance data on overhead network lines up to 138kV;  Time-stamped event recordings;  Line status, fault waveform, outages, load profile, ambient and conductor temperatures, voltage sensing, displacement power factor, voltage reading (with an external insulated resistor); Key features include:  Maintenance-free  Rapid installation for instant intelligence  Intuitive software  Flexible remote communications options  SCADA protocol compatible  Versatile applications Key specifications include:  Fault capture range: 1A - 25kA;  Line frequency: 45Hz - 65Hz;  Operating temperature: -40°C to +70°C;  Ingress Protection: IP66;  Housing material: UV stabilised polycarbonate;  Dimensions: H: 315mm, D: 180mm, W: 140mm;  Weight: 2kg;  Battery powered and solar charged (2D movement 0.5W panel); and  Includes 4 x 2V, 2.5Ah rechargeable (SLA batteries) and last approximately 45 days without sunlight.  Installation: Conductor range: 6mm to 32mm. No outage required. Easily installed on energised lines using a hot stick.
  • 51. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 51 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 6.1.2 Pole Mounted Sensor The LIQ35 is a reliable pole mounted solar powered line fault indicator (with battery backup) for use on three phase three wire, and SWER overhead line systems. The LIQ35 utilises a fault detection algorithm that adapts to network parameters and requires no configuration. Key features include:  Continuous fault indication;  Fault types: Permanent faults; Transient faults; Outage events; Closure events; Self- clearing faults (fault current without loss of voltage);  Patented adapting fault algorithm;  Dual magnetic field sensors for improved fault capture;  Voltage sensing to accurately identify outages and trips;  Time and data stamped event recording;  Recognition of line voltage return;  Two visual indicators displaying line status and most recent fault;  Inrush restraint to ensure only real faults are reported;  SCADA protocol compatible (DNP3); and  Advanced programmable options for maximum flexibility. Key specifications include:  Line voltage: 5kV to 145kV;  Rechargeable batteries: 4 x 2V, 2.5Ah Sealed lead-acid  Battery Life: up to 10 years;
  • 52. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 52 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831  Solar panel: 3V, 1W;  Operation without solar (no active communications): 45 days;  Operating temperature: -40°C to +85°C;  Altitude: 1800m;  Local communications: 2.4GHz spread spectrum 50m range (line of sight);  Integrated remote communications: Embedded 3G cellular (PCI Express Mini Card);  Ambient temperature sensor (optional): -40°C to +85°C;  LED indicator – visibility (daylight / night time): 50m/50m;  Weight: 2.2kg;
  • 53. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 53 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 6.2 Indoor and Outdoor Voltage Transformers 6.2.1 Indoor Single Phase Single Pole Voltage Transformers
  • 54. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 54 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 6.2.2 Indoor Single Phase Double Pole Voltage and Control Transformers
  • 55. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 55 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 6.2.3 Indoor Voltage Three Phase Voltage Transformers
  • 56. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 56 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
  • 57. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 57 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 6.2.4 Draw-Out Voltage Transformers 6.2.5 Outdoor Voltage and Control Transformers 6.2.5.1.1 Oil Immersed Version 6.2.5.1.2 Cast Resin Version
  • 58. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 58 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 6.2.6 Outdoor Metering Units 6.3 Indoor and Outdoor Current Transformers 6.3.1 Indoor Ring Type, Window Type and Bus Duct (up to 36kV)  Typically for currents of 200A and above - depending on burden and accuracy requirements.  Inner diameters from 65 mm to 170 mm available for ring type, and up to (110 x 75) mm for window type.  Pigtail is provided for CTs of rating 6.6 kV and above, and should be connected to the primary bar to obtain an equi-potential (discharge-free) connection.  Large diameter bus duct CTs are available, suitable for up to 30000 A.  Suitable for high short time ratings.
  • 59. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 59 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 6.3.2 Indoor Bar Primary Current Transformers (up to 36kV)
  • 60. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 60 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 6.3.3 Indoor Wound Primary (block Type) Current Transformers (up to 36kV) Suitable for current ratings up to 4000A:  Primary connecting pad sizes vary depending upon primary current  Standard frame widths of 148, 160, 180, 205, 240 mm  Suitable for short time rating of 50 kA/3 seconds
  • 61. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 61 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 6.3.4 Outdoor Current Transformers
  • 62. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 62 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 7 Power Quality Mitigation Products 7.1 Reactors and Filters We can source appropriate line side and load side reactors and filters to address the identified causes of poor power quality. 7.2 Power Factor Correction Units We work with local manufacturers and suppliers to provide appropriately sized PFC units. We can custom design to your requirements and also offer a segregated design that not only enables more efficient service and maintenance but also ensures the sensitive control components are not affected by heat generated by the harmonic blocking reactors and hence prolonging the life of the equipment. Up to 100kVar Wall Mount Cubicle 1000H x 800W x 300D (wall mount cubicle without reactor segregation) Up to 250kVar Cubicle 2000H x 800W x 600D (expandable to 300kVar if no isolator or circuit breaker required) Up to 550kVar Cubicle 2000H x 1250W x 600D (expandable to 600kVar if no isolator or circuit breaker required) Up to 800kVar Cubicle 2000H x 2050W x 600D (expandable to 900kVar if no isolator or circuit breaker required) Up to 1000kVar Cubicle 2000H x 2500W x 600D Switched Capacitor Bank: Thyristor controlled switching technology - mitigates the effects of fast switching loads (lifts, welding equipment, oil and gas drilling rigs; and mine site drilling equipment).
  • 63. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 63 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 7.3 Active Harmonic Filtering Wall-Mounted Active Filter ADF P100 The ADF P100 is an ultra-efficient, easy to use solution in a wall mounted cabinet. The tall and narrow design allows installation where space is at a premium. It has a nominal current of 70 to 100 A RMS and is available in the voltage range 208 - 480 V RMS nominal. ADF P200 Active Filter The ADF P200 is a very fast active filter and can eliminate harmonic problems up to the 100th harmonic and works well in even very resonant grids. It is suitable for mitigating resonances, interharmonics and high frequency disturbances. ADF P300 Active Filter The ADF P300 is suitable for commercial and industrial loads. STATCOM (Static Synchronous Compensator) Is a shunt device, which uses force-commutated power electronics (i.e. GTO, IGBT) to control power flow and improve transient stability on electrical power networks.
  • 64. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 64 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 ADF P700 STATCOM: The ADF P700 is a high power, utility grade, medium voltage STATCOM for heavy industrial loads. It is useful for dynamic reactive compensation, flicker mitigation, and harmonic suppression in applications such as electric arc furnaces, cranes, hoists and wind farms. The ADF P700 is available in modular 3 MVA or 6 MVA compensation power. Several units can be operated in parallel to achieve higher power levels.
  • 65. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 65 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 8 Consulting and Services 8.1 Consulting in Power Quality 8.1.1 Power Quality Investigation This includes:  Site Survey  Site Monitoring  Data Analysis and Identification  Reporting and Recommendations 8.1.2 Power Quality Mitigation Following the Power Quality Investigation, we then propose solutions to mitigate the contributing aspects to poor power quality. This includes proposing products and equipment followed by further monitoring for validation. 8.1.3 Power Quality Management Your electrical distribution system may be changing - growing (adding more elements to do more work). In this case we would recommend a Power Quality Management Plan for continuous monitoring and assessment. 8.2 Training 8.2.1 Product Training Product training is provided on all electronic monitoring products and customised equipment sold and or designed by CHK Power Quality Pty Ltd. 8.2.2 Professional Training A single day course is offered in Power Quality with a certificate awarded upon completion. The course covers an overview of power systems in Australia, introduces concepts of power quality, monitoring and reporting and how to improve power quality. 8.3 Technical Support 8.3.1 Product Support Product support is provided on all electronic monitoring products and customised equipment sold and or designed by CHK Power Quality Pty Ltd and some products designed by GridSense; please enquire. 8.3.2 Calibration and Repairs We have a service department that provide repairs and calibration for our electronic products.
  • 66. PRODUCTS AND SERVICES CATALOGUE - 22 SEP 2014. Page 66 Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au; Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831 8.4 Low Volume Contract Manufacturing We have over fifteen years of experience in low volume production. Items include: wire looms; leads and probes; building electronic circuit boards (hand soldering) and product sub-assemblies. 8.5 Engineering and Project Management Services 8.5.1 Feature Requests and New Features Where possible, we can update a product to include a specific feature to address your requirement. 8.5.2 Design Our engineering team can custom-design a solution (involving industrial design, electronic, firmware and software development) and manage the whole product development cycle, from specification to testing and approvals.