33 OIL SEPARATORS

33.1

INTRODUCTION ............................................................................................................. 33-1
33.1.1
33.1.2

Types of Separator............................................................................................ 33-1

33.1.3
33.2

Application and Purpose .................................................................................... 33-1

Flow Configuration ............................................................................................ 33-2

DESIGN AND SIZING...................................................................................................... 33-3
33.2.1
33.2.2

Degree of Treatment......................................................................................... 33-3

33.2.3

Design Flow Rate .............................................................................................. 33-3

33.2.4

Flow Balancing Storage Volume......................................................................... 33-4

33.2.5

API (American Petroleum Institute) Tank Sizing ................................................. 33-4

33.2.6

Plate Separator Sizing ....................................................................................... 33-4

33.2.7
33.3

Design .............................................................................................................. 33-3

Flow Control Device .......................................................................................... 33-4

OTHER DESIGN CONSIDERATIONS................................................................................. 33-5
33.3.1
33.3.2

33.4

Oil Retention Baffles.......................................................................................... 33-5
Flow Spreading Baffles...................................................................................... 33-5

MAINTENANCE ............................................................................................................... 33-5

APPENDIX 33.A WORKED EXAMPLE ........................................................................................... 33-7

Urban Stormwater Management Manual

33-i
Oil Separators

33.1

More relevant applications are for :

INTRODUCTION

•

Oil separation devices are applicable for stormwater runoff
from areas where hydrocarbon products are handled or
where small spills routinely fall on paved surfaces exposed
to rain.
The objective of the oil separators is to treat most of the
flow (90 to 95%) from a potentially contaminated
catchment to an acceptable degree (10 – 20 mg/l oil and
grease) and to remove free floating oil. In addition to
collecting oil, which rises to the surface, separators collect
sediment, which falls to the bottom of the devices. In fact,
the sediment is likely to contain petroleum products, which
are attached to fine sediments. Oil separation devices
sized in accordance with the guidelines in this Chapter will
achieve a sufficient degree of sedimentation so further
sedimentation devices would not be required.
Oil in general urban stormwater runoff is likely to be in the
form of an emulsion, which is intimately mixed with the
water. Such oil will not readily float out, so oil separators
are not used for treatment of general urban runoff.
Oil separators need to treat only the stormwater runoff
from oily areas or areas which may become oily. General
stormwater runoff from other areas should be routed away
from the separator and treated for sediment removal in the
usual fashion. Treatment should be as close to the source
of the oil-generating activities as possible.
High rates of runoff and practical limitations on the
treatment process mean that oil separators can only be
used for small catchment areas. For Malaysian conditions
the practical maximum catchment area that can be treated
is in the order of 1000 m2 ( 0.1 hectare).

Figure 33.1

Urban Stormwater Management Manual

service stations,

•

33.1.1 Application and Purpose

yards where petroleum products are stored or
handled, or vehicles are serviced, and

•

heavily used highway parking lots.

The potential also exists to use separators (and in
particular, the balancing storage) for containment of
accidental oil spills, in addition to their primary function of
treatment. Spills will enter the separator via the site
drainage system and mix with the water in the separator,
then the oil in the spill will rise to the surface. If the
separator is to be used for spill containment, it should be
ensured that the separator can hold the anticipated spill
volume. Additional storage may be required.
33.1.2 Types of Separator
API tanks (see Figure 33.1) and plate separators are the
more efficient oil separators. API tanks were originally
designed by the American Petroleum Institute (API) for use
in refinery applications, but modifications of the design can
be used for stormwater treatment.
Plate separators (see Figure 33.2) contain packs of plates,
typically spaced at 10 mm to 20 mm centres. The plates
increase the effective surface of the device. Viewed
another way, the close spacing of the plates reduces the
height that an oil droplet must rise before it reaches a
collecting surface. Therefore, to achieve the same degree
of treatment as an API tank, a much smaller device can be
used. This will result in less land area being taken up and
less excavation, which will more often than not
compensate for the higher cost of the plate packs. Plate
separators are often supplied by manufacturers as
proprietary devices.

Schematic of API Separator

33-1
Oil Separators

recommended configuration is shown schematically in
Figure 33.3.
(a)

Flow balancing

A storage tank is provided upstream of the separator to
reduce the peak inflow rate to that which the separator
can handle. The stored runoff is treated slowly through
the separator in the period between storms. The flow
rate through the separator is then more even or
‘balanced’.

Figure 33.2

Schematic of Plate Separator
(Meyers, 1980)
33.1.3 Flow Configuration
Oil separators, which receive stormwater runoff, should
be installed with a high flow bypass and flow balancing,
unless special circumstances make it impractical. The
high flow bypass diverts excess flows away from the
separator, ensuring that it is not overloaded. Flow
balancing uses storage to reduce the peak inflow rate
and increase the efficiency of the separator. The

Figure 33.3

33-2

In large storms, the storage area may fill completely, in
which case some flow is bypassed without treatment.
The storage area may consist of a tank or bunded area.
The potential also exists to use the storage area for
containment of fuel spills.
(b)

High-flow Bypass

The bypass configuration is also shown in Figure 33.3.
The bypass begins to operate when the balancing
storage becomes full. At this stage the water level in the
bypass is at the bypass weir level and the flow through
the separator is controlled hydraulically to Qd (the
separator design flow). Careful hydraulic design is
necessary to achieve this condition.

Oil Separator with Bypass and Flow Balancing

Urban Stormwater Management Manual
Oil Separators

Usually flow throttling will be at the outlet of the tank
because if the flow constriction orifice were at the inlet, the
oil may become emulsified. Furthermore, an orifice at the
outlet is less likely to clog. A non-emulsifying (e.g.
diaphragm) pump may be used instead of flow throttling to
control the flow rate to the separator. The bypass weir
should be long enough to pass the maximum design flow
in the incoming pipe while keeping the flow to the
separator small enough to ensure that oil re-entrainment
does not occur.

33.2

DESIGN AND SIZING

33.2.1 Design
Oil separators shall be divided into three compartments by
baffles or berms: a forebay (inlet chamber), an oil
separator cell, and an afterbay (outlet chamber). The
forebay is primarily to trap and collect sediments,
encourage plug flow and reduce turbulence. The oil
separator cell is to trap and hold oil. The afterbay provides
a relatively oil-free exit cell from the outlet.
The length of the forebay shall be approximately 1/3 of the
total length of the three cells (see Figure 33.1). The oilretaining baffle shall be located approximately 1/4 of the
total length of the three cells from the outlet wall.

greater than 150 µm in diameter (Washington State
Department of Ecology, 1990).
Traditionally, 150 µm separation has been used overseas,
which typically results in an effluent oil and grease
concentration of 50 – 100 mg/l (Meyers, 1980). Typically
standards for industrial discharges in Australia are 10-20
mg/l, which generally corresponds to the removal of
droplets larger than 60 µm (Meyers, 1980). Separation of
the 60 µm droplet was adopted as the basis for design for
devices in Australia and New Zealand; this figure
corresponds to the lower tail of the droplet size distribution
and should result in an effluent quality of 10 - 20 mg/l at
the design flow.
The rise velocity for a 60 µm droplet can be calculated,
given the water temperature (which affects the viscosity of
the water) and the density of the oil. This rise velocity is
then used in the sizing calculations for the device. The rise
velocity may be calculated according to:
Vr =

•

•

(a)

What level of treatment is achieved for flow, which is
passed through the separator? In other words, what
is the design level of treatment at the design flow
rate?
What fraction of the runoff from the catchment is
passed through the separator ? A higher flow capacity
of the separator or a larger flow balancing area will
result in more flow being treated.
Design Level of Treatment at Design Flow Rate

Grease and oil, which is not emulsified, dissolved or
attached to sediment, will be present as oil droplets or as a
surface slick. If only large droplets can be removed, then
small droplets will pass through the device and into the
receiving water body. If small droplets can be removed,
then effluent quality will be improved (at the expense of
requiring a slower passage of stormwater through the
device, because smaller droplets rise more slowly).
No data are available on the size distribution of oil droplets
in stormwater from commercial or industrial areas, but
some overseas data are available for petroleum product
storage terminals. These data indicate that about 80% of
droplets (by volume) are greater than 90 µm and 30% are

Urban Stormwater Management Manual

(33.1)

where s = specific gravity of the oil,
D = the droplet diameter (m),
υ = kinematic viscosity of water, and
g = gravitational acceleration (9.8 m/s2).

33.2.2 Degree of Treatment
The degree of treatment achieved by the separator system
depends on two factors:

g D 2 (1 − s )
18υ

At 15°C and for an oil specific gravity of 0.9, the rise
velocity of a 60 µm droplet using Equation 33.1 is
0.62 m/hr and this is the recommended design value for
most situations.
(b)

Fraction of Runoff Treated

The objective is to treat 90% to 95% of the runoff from
the catchment on a long term basis (not for each and
every rain event). The choice of the degree of treatment
is based on rainfall analysis, as discussed in Chapter 13.
This degree of treatment leads to a required separator flow
capacity, and possibly a requirement for flow balancing
storage.
33.2.3 Design Flow Rate
The required design flow rate is that from the water quality
design storm (see Chapter 4). This 3 month ARI flow (and
smaller flows) should be passed through the flow balancing
storage and the device, and flows in excess of this amount
are bypassed. This means that only 5% - 10% of the flow
is bypassed (on a long term basis, not for each flow
event).
The peak design inflow rate can be computed using the
Rational Method or hydrograph methods, as described in
Chapter 14.

33-3
Oil Separators

Table 33.1

For service stations, the catchment area should include an
allowance for rain, which manages to get under the
canopy. In some cases washout water from under the
canopy areas in service stations, or spill-down water from
open paved areas, will be passed to the separator. It is
unlikely that wash-down and heavy rain will occur at the
same time, so it is not necessary to add the wash-down
flow to the stormwater runoff flow. Rather, the maximum
of the stormwater runoff flow and the wash-down flow can
be used to size the separator. That is, if the wash-down
flow is larger that the calculated peak inflow, then use the
wash-down flow as the design flow.

U /Vr
15

33.2.5 API (American Petroleum Institute) Tank
Sizing
The horizontal velocity U in the tank is calculated as:
(33.2)

where d = tank depth and
W = tank width

F Qd
Vr

(33.3)

Based on plug flow, the above relationship ensures that a
droplet with rise velocity Vr will rise to the surface during
its passage through the tank. The required rise velocity is
the rise velocity of a 60 µm oil droplet (see Section
33.2.2(a)), which for a temperature of 15°C and an oil
specific gravity of 0.9, is 0.62 m/hr. The dimensionless
factor F accounts for short-circuiting and turbulence
effects, which degrade the performance of the tank. This
factor depends on the ratio of horizontal velocity (U) to rise
velocity (Vr), as shown in Table 33.1.
The volume and area determined from this tank sizing
refer to the dimensions of the main compartment of the
tank. Additional volume should be allowed for inlet and
outlet sections in the tank.

33-4

1.52

6

1.37

3

1.28

•

U
≤ 15
Vr

•

0.3 W ≤ d ≤ 0.5 W

•

2m<W<5m

•

1 m < d < 2.5 m

where d is the depth and W is the width of the tank.
Some of these dimensions will not be appropriate for
smaller catchments and may need to be relaxed.
To avoid re-entrainment and degradation of performance,
it is required that the maximum horizontal flow velocity in
the main part of the tank be less than 25 m/hr (when the
bypass is operating at the maximum flow).
33.2.6 Plate Separator Sizing

The plan area (Ad) for the separator cell is based on the
rise velocity (Vr) and design flow rate (Qd), according to
the formula:
Ad =

1.64

10

The required volume of the flow-balancing compartment
depends on the design storm runoff rate and volume and
the treatment rate of a separator. The calculation of the
balancing volume is done by storage routing, as described
in Chapter 14.
A worked example is given in
Appendix 33.A (ii).

Qd
d ×W

F Factor

Other dimensional requirements (from American Petroleum
Institute, 1969) are:

33.2.4 Flow Balancing Storage Volume

U =

F Factor for API Separators

A flowchart for the sizing of an API plate separator is given
in Figure 33.4.
Plate separators are available from several suppliers. The
suppliers will be able to provide an appropriate size of
device to achieve 60 µm droplet separation at the chosen
design flow rate (Qd). The required effective area can be
calculated from:
AE =

Qd
Vr

(33.4)

where AE = effective area
Some increase in the calculated size should be allowed, to
account for short-circuiting.
33.2.7 Flow Control Device
(a)

Orifice Sizing (Inlet pipe to separator)

For a round orifice plate flowing full, with head (h), the
area of the orifice is estimated from:

Urban Stormwater Management Manual
Oil Separators

Ao =

Qd
0.6 2 gh

(33.5)

where Qd = the design flow (m3/s),
A0 = area of the orifice (m2),
g = gravitational acceleration (m/s2), and
h = head (m).
Other means of throttling the inlet may be used, with
design based on the appropriate head loss formula. As an
alternative to hydraulic flow control a non-emulsifying
pump may be used to control the flow rate.
The recommended orifice sizing procedure is as follows:
1.

Choose an orifice diameter and calculate the orifice
area. Consideration should be given to the risk of
blockage.

2.

Calculate the water level in the bypass when the
design flow, Qd is being passed through the separator.
Set the bypass weir at this level.

3.

Calculate the head over the bypass weir (hw) (using an
assumed weir length) when the weir is passing Qw ,
the maximum flood flow to go over the bypass. A
standard weir equation may be used to calculate this
head.

4.

Calculate the flow through the separator when the
bypass weir is passing Qw. If this flow is larger than
the maximum allowed flow through the separator,
then either increase the bypass weir length and return
to Step 3, or reduce the orifice area and return to Step
1. The maximum allowed flow for a plate separator is
2 times Qd while the maximum allowed flow for an API
tank is the flow corresponding to a horizontal velocity
of 25 m/hr.

An outlet baffle extending from the surface down is
required to stop trapped oil from passing over the outlet
weir.
33.3.2 Flow Spreading Baffles
To achieve even flow distribution across tanks at the inlet,
baffled inlet ports or other devices are used. API (1969)
recommended slotted inlet baffles, while other devices
such as those used in settling tanks in wastewater
treatment plants may be used.
The sizing of the inlet ports or baffles should be such that
some head loss is provided (to spread flow), but it is
recommended that velocities should be less than 0.5 m/s,
at the maximum separator flow to avoid oil emulsification.

33.4

MAINTENANCE

With any oil separation device maintenance is essential.
Oil and solids build up to such a degree that gross reentrainment of captured pollutants occurs. The devices
are then ineffective.
For this reason, maintenance
schedules must be submitted with the permit application.
Oil Removal – The separator should be inspected
periodically and frequently to determine the amount of oil
collected. Oil should be removed if necessary (by pumping
or decanting). For automatic oil skimming systems, checks
can be less frequent, since, if the oil outlet device is
working properly, oil should not collect to a great depth.
Oil will usually be decanted or pumped to a storage tank or
barrel, which should be checked periodically. If the tank or
barrel is full, the oil should be removed for re-refining or
disposal.

In some situations it may be desirable to use flow
throttling at the inlet to the tank rather than at the outlet.
In this situation there would be less variation of water level
in the tank (which is beneficial for oil skimming) but there
would be larger velocities at the inlet (which may cause oil
emulsification). To avoid emulsification, it is recommended
that flow velocities through an inlet flow control orifice be
limited to less than 0.5 m/s.

Oil Absorbing Pads – Pads (if used) should be checked and
replaced if they are saturated. The used pads should be
disposed of in an appropriate manner.

33.3

Removal of Sediment – The slurry at the bottom of the
tank should be removed periodically and disposed of.
Sediment removal from the bypass may be required as
well. Sediment should also be removed from the flow
balancing compartment (if used).

OTHER DESIGN CONSIDERATIONS

33.3.1 Oil Retention Baffles
An inlet baffle is required so that oil collected in the tank
does not pass back into the bypass and over the bypass
weir. The baffle may consist of a wall extending down
from the surface. Alternatively, an inverted elbow, or
preferably a tee (to make cleaning easier), may be
attached to the inlet pipe as shown in Figure 33.1. The tee
extends down below the oil level so oil will not pass back
into the bypass.

Urban Stormwater Management Manual

Oil Skimmer Operation – The bypass should be checked to
determine whether oil is collecting in the bypass. If so, the
oil should be removed and modifications to the pipe
between the bypass and separator should be considered.

Cleaning of Screens – Screens, which remove debris or
protect the flow control orifice (if used) should be cleaned
regularly.
Clearing of Orifices – Orifices and inlet pipes should be
checked regularly for clogging and should be unplugged if

33-5
Oil Separators

necessary. If clogging is a persistent problem, then further
screening should be used.

separator is not operating. It should be compared with the
design value and the weirs adjusted if necessary.

Weir Levels – A check should be made of the elevation of
the bypass weir with respect to the water level when the

Access – Easily removed covers and easily accessed
screens and orifices should be used. This will ensure ease
of maintenance.
See Chapter 14. Hydrograph
methods are required for
calculation of storage

1. Calculate inflow
hydrograph

2. Choose separator design
flow Qd

Consult the manufacturer's
recommendations

3. Choose d and W/d for
separator

4. Calculate Vr and U

No

5. U<25mm/hr
and U/Vr<15 ?

No

Equations 33.1 and 33.2

Refer to Section 33.2.4

Yes
6. Determine F and Ls

7. Is oil separator
size reasonable ?

Consider site constraints

Yes

8. Determine separator
dimensions Lr , Ls , La

Figure 33.4

33-6

9. Determine flow
balancing requirements

Flow Chart for Sizing of API Oil Separator

Urban Stormwater Management Manual
Subject Index

APPENDIX 33.A WORKED EXAMPLE
A service station is fitted with an oil separator. The layout is shown in Figure 33.A1. Runoff from unpaved areas, the
covered forecourt, and areas unlikely to be contaminated with oil is routed away from the separator. This leaves a paved
oily surface of 300m2 draining to the oil separator. The wash-down water from the carwash is routed to the sanitary sewer.

Figure 33.A1

API Tank Design for Example Service Station

Step 1. Design Flow
C = 0.9 for impervious area

A = 300 m2

tc = 5 min (assumed)

I5 for 3 month ARI and tc of 5 min = 120mm/hr

Qpeak =
=

CIA
360

(Equation 14.7, see Chapter 14).

(0.9 x 120 x 0.03)
= 0.009 m3/s = 32.4 m3/hr
360

Urban Stormwater Management Manual

7
Oil Separators

Step 2
From the manufacturer’s advice, the design flowrate Qd = 5 m3/hr
Step 3. Trial sizing of oil separator
Try d = 1.0 m and W=2.5 m
Step 4
For design flowrate Qd = 5 m3/hr
U =Q/(d.W) = 5/(1.0 x 2.5) = 2 m/hr (Equation 33.2)
For a design particle size of 60 µm or larger oil droplets, Vr = 0.62 m/hr (Equation 33.1)
U/Vr =

2
= 3.23
0.62

Step 5
The trial design complies with velocity limits, so it is accepted.
Step 6
From Table 33.1, F = 1.28
Plan area of API separator cell Ad
=

5 x 1.28
= 10.3 m2 hr (Equation 33.3)
0.62

Length of separator cell Ls = Ad /W
Ls = 10.3/2.5 =4.12 m
Step 7
The trial design is considered to be acceptable as it meets site constraints.

Step 8
Total length of separator L (refer Figure 33.1):
L = Lf + Ls +La
L = L/3 + 4.12 + L/4
(1 – 0.33 – 0.25) x L = 4.12
L = 9.8 m, say 10 m overall
Step 9. Calculation for Flow Balancing
(i)

The critical design storm for storage will be longer than the calculated tc. Try a series of different durations.

Trial t = 20 min (assumed)
Qpeak =
=

(ii)

33-8

CIA
360

I5 for 3 month ARI and tc of 20 min = 94.13 mm/hr
(Equation 14.7, see Chapter 14).

(0.9 x 94.13 x 0.03)
= 0.0071 m3/s
360
The storage routing calculation for flow balancing is shown in the following table.

Urban Stormwater Management Manual
Subject Index

Table 33.A1
Cumulative Time
(min)

Routing Calculation for Flow Balancing Storage

Inflow

Inflow Volume

Outflow

(m3/s)

(m3)

(m3/hr)

Outflow Volume
(m3)

Cumulative Storage
(m3)

0

0

2.5

0.0035

0.263

5

0.104

0.159

5

0.0071

0.795

5

0.208

0.746

7.5

0.0071

1.065

5

0.208

1.603

10

0.0071

1.065

5

0.208

2.460

12.5

0.0071

1.065

5

0.208

3.317

15

0.0071

1.065

5

0.208

4.174

17.5

0.0071

1.065

5

0.208

5.031

20

1.065

5

0.208

5.888

0.0035

0.795

5

0.208

6.475

25
(iii)

0.0071

22.5

0

0.263

5

0.208

6.530

Repeat the calculation for storm durations of 30 min, 45 min, 60 min, etc.
These calculations give the following results:
Storm Duration (min)

Cumulative Storage (m3)

20

6.53

30

6.69

45

6.99

60

6.67

90

5.41

120

3.71

The critical storm duration (that which gives the largest storage requirement) for the balancing storage is
45 minutes and the volume required for flow balancing = 7 m3

Urban Stormwater Management Manual

9

More Related Content

What's hot

AIR COOLED HEAT EXCHANGER
AIR COOLED HEAT EXCHANGERAIR COOLED HEAT EXCHANGER
AIR COOLED HEAT EXCHANGERAhsan Shakil
 
Separator sizing and droplet sizes low shear school - 2017
Separator sizing and droplet sizes   low shear school - 2017Separator sizing and droplet sizes   low shear school - 2017
Separator sizing and droplet sizes low shear school - 2017Low Shear School
 
Heat Exchanger and Its Types.pptx
Heat Exchanger and Its Types.pptxHeat Exchanger and Its Types.pptx
Heat Exchanger and Its Types.pptxAtif Razi
 
Methanol Loop Start Up and Shut Down
Methanol Loop Start Up and Shut DownMethanol Loop Start Up and Shut Down
Methanol Loop Start Up and Shut DownGerard B. Hawkins
 
Failure in synthesis converter
Failure in synthesis converterFailure in synthesis converter
Failure in synthesis converterPrem Baboo
 
Heat Exchanger
Heat ExchangerHeat Exchanger
Heat ExchangerNathan
 
Compressor trouble shooting
Compressor trouble shootingCompressor trouble shooting
Compressor trouble shootingGanesh Murugan
 
Design of Gas and Oil Separator 2023.pdf
Design of Gas and Oil Separator 2023.pdfDesign of Gas and Oil Separator 2023.pdf
Design of Gas and Oil Separator 2023.pdfAl AYAn University
 
Functional Design of Heat Exchanger
Functional Design of Heat ExchangerFunctional Design of Heat Exchanger
Functional Design of Heat ExchangerShubhajit Sarkhel
 
Mechanical Seals Piping Plans Api 628
Mechanical Seals Piping Plans   Api 628Mechanical Seals Piping Plans   Api 628
Mechanical Seals Piping Plans Api 628IONEL DUTU
 
Fouling effects on boiler
Fouling effects on boilerFouling effects on boiler
Fouling effects on boilerMaharshi Soni
 
METHODOLOGY FOR SLUG CATCHER SIZING
METHODOLOGY FOR SLUG CATCHER SIZINGMETHODOLOGY FOR SLUG CATCHER SIZING
METHODOLOGY FOR SLUG CATCHER SIZINGVijay Sarathy
 
Thermal rating of Shell & Tube Heat Exchanger
Thermal rating of Shell & Tube Heat ExchangerThermal rating of Shell & Tube Heat Exchanger
Thermal rating of Shell & Tube Heat ExchangerVikram Sharma
 
Design and Rating of Trayed Distillation Columns
Design and Rating  of Trayed Distillation ColumnsDesign and Rating  of Trayed Distillation Columns
Design and Rating of Trayed Distillation ColumnsGerard B. Hawkins
 

What's hot (20)

AIR COOLED HEAT EXCHANGER
AIR COOLED HEAT EXCHANGERAIR COOLED HEAT EXCHANGER
AIR COOLED HEAT EXCHANGER
 
Separator sizing and droplet sizes low shear school - 2017
Separator sizing and droplet sizes   low shear school - 2017Separator sizing and droplet sizes   low shear school - 2017
Separator sizing and droplet sizes low shear school - 2017
 
Heat Exchanger and Its Types.pptx
Heat Exchanger and Its Types.pptxHeat Exchanger and Its Types.pptx
Heat Exchanger and Its Types.pptx
 
Three Phase Separators
Three Phase SeparatorsThree Phase Separators
Three Phase Separators
 
Methanol Loop Start Up and Shut Down
Methanol Loop Start Up and Shut DownMethanol Loop Start Up and Shut Down
Methanol Loop Start Up and Shut Down
 
Failure in synthesis converter
Failure in synthesis converterFailure in synthesis converter
Failure in synthesis converter
 
Heat Exchanger
Heat ExchangerHeat Exchanger
Heat Exchanger
 
Compressor trouble shooting
Compressor trouble shootingCompressor trouble shooting
Compressor trouble shooting
 
Design of Gas and Oil Separator 2023.pdf
Design of Gas and Oil Separator 2023.pdfDesign of Gas and Oil Separator 2023.pdf
Design of Gas and Oil Separator 2023.pdf
 
Heat Exchanger
Heat ExchangerHeat Exchanger
Heat Exchanger
 
Functional Design of Heat Exchanger
Functional Design of Heat ExchangerFunctional Design of Heat Exchanger
Functional Design of Heat Exchanger
 
Mechanical Seals Piping Plans Api 628
Mechanical Seals Piping Plans   Api 628Mechanical Seals Piping Plans   Api 628
Mechanical Seals Piping Plans Api 628
 
Fouling effects on boiler
Fouling effects on boilerFouling effects on boiler
Fouling effects on boiler
 
METHODOLOGY FOR SLUG CATCHER SIZING
METHODOLOGY FOR SLUG CATCHER SIZINGMETHODOLOGY FOR SLUG CATCHER SIZING
METHODOLOGY FOR SLUG CATCHER SIZING
 
Compressor
CompressorCompressor
Compressor
 
Thermal rating of Shell & Tube Heat Exchanger
Thermal rating of Shell & Tube Heat ExchangerThermal rating of Shell & Tube Heat Exchanger
Thermal rating of Shell & Tube Heat Exchanger
 
Design and Rating of Trayed Distillation Columns
Design and Rating  of Trayed Distillation ColumnsDesign and Rating  of Trayed Distillation Columns
Design and Rating of Trayed Distillation Columns
 
column tray detail.pdf
column tray detail.pdfcolumn tray detail.pdf
column tray detail.pdf
 
Oil and gas separators
Oil and gas separatorsOil and gas separators
Oil and gas separators
 
Cooling tower
Cooling towerCooling tower
Cooling tower
 

Viewers also liked

Ch 20 community regional detention
Ch 20   community regional detentionCh 20   community regional detention
Ch 20 community regional detentionFuad Chiwa
 
Ch 28 engineered waterways
Ch 28   engineered waterwaysCh 28   engineered waterways
Ch 28 engineered waterwaysFuad Chiwa
 
Ch 31 filtration
Ch 31  filtrationCh 31  filtration
Ch 31 filtrationFuad Chiwa
 
Ch 11 hydrologic design concepts
Ch 11   hydrologic design conceptsCh 11   hydrologic design concepts
Ch 11 hydrologic design conceptsFuad Chiwa
 
Ch 1 malaysian perspective
Ch 1   malaysian perspectiveCh 1   malaysian perspective
Ch 1 malaysian perspectiveFuad Chiwa
 
Ch 16 system design
Ch 16   system designCh 16   system design
Ch 16 system designFuad Chiwa
 
Ch 3 stormwater management
Ch 3   stormwater managementCh 3   stormwater management
Ch 3 stormwater managementFuad Chiwa
 
Ch 4 acceptance criteria
Ch 4   acceptance criteriaCh 4   acceptance criteria
Ch 4 acceptance criteriaFuad Chiwa
 
Ch 21 on-site and community retention
Ch 21   on-site and community retentionCh 21   on-site and community retention
Ch 21 on-site and community retentionFuad Chiwa
 
Ch 22 regional retention
Ch 22   regional retentionCh 22   regional retention
Ch 22 regional retentionFuad Chiwa
 
Ch 14 flow estimation routing
Ch 14   flow estimation routingCh 14   flow estimation routing
Ch 14 flow estimation routingFuad Chiwa
 
Ch 10 choice of management options
Ch 10   choice of management optionsCh 10   choice of management options
Ch 10 choice of management optionsFuad Chiwa
 
Ch 18 principles of quantity control
Ch 18   principles of quantity controlCh 18   principles of quantity control
Ch 18 principles of quantity controlFuad Chiwa
 
Ch 8 strategic planning
Ch 8   strategic planningCh 8   strategic planning
Ch 8 strategic planningFuad Chiwa
 
Ch 26 open drains
Ch 26   open drainsCh 26   open drains
Ch 26 open drainsFuad Chiwa
 
Ch 29 hydraulic structures
Ch 29   hydraulic structuresCh 29   hydraulic structures
Ch 29 hydraulic structuresFuad Chiwa
 
Ch 47 hillside drainage
Ch 47   hillside drainageCh 47   hillside drainage
Ch 47 hillside drainageFuad Chiwa
 
Ch 27 culverts
Ch 27   culvertsCh 27   culverts
Ch 27 culvertsFuad Chiwa
 

Viewers also liked (19)

Ch 34 gp ts
Ch 34   gp tsCh 34   gp ts
Ch 34 gp ts
 
Ch 20 community regional detention
Ch 20   community regional detentionCh 20   community regional detention
Ch 20 community regional detention
 
Ch 28 engineered waterways
Ch 28   engineered waterwaysCh 28   engineered waterways
Ch 28 engineered waterways
 
Ch 31 filtration
Ch 31  filtrationCh 31  filtration
Ch 31 filtration
 
Ch 11 hydrologic design concepts
Ch 11   hydrologic design conceptsCh 11   hydrologic design concepts
Ch 11 hydrologic design concepts
 
Ch 1 malaysian perspective
Ch 1   malaysian perspectiveCh 1   malaysian perspective
Ch 1 malaysian perspective
 
Ch 16 system design
Ch 16   system designCh 16   system design
Ch 16 system design
 
Ch 3 stormwater management
Ch 3   stormwater managementCh 3   stormwater management
Ch 3 stormwater management
 
Ch 4 acceptance criteria
Ch 4   acceptance criteriaCh 4   acceptance criteria
Ch 4 acceptance criteria
 
Ch 21 on-site and community retention
Ch 21   on-site and community retentionCh 21   on-site and community retention
Ch 21 on-site and community retention
 
Ch 22 regional retention
Ch 22   regional retentionCh 22   regional retention
Ch 22 regional retention
 
Ch 14 flow estimation routing
Ch 14   flow estimation routingCh 14   flow estimation routing
Ch 14 flow estimation routing
 
Ch 10 choice of management options
Ch 10   choice of management optionsCh 10   choice of management options
Ch 10 choice of management options
 
Ch 18 principles of quantity control
Ch 18   principles of quantity controlCh 18   principles of quantity control
Ch 18 principles of quantity control
 
Ch 8 strategic planning
Ch 8   strategic planningCh 8   strategic planning
Ch 8 strategic planning
 
Ch 26 open drains
Ch 26   open drainsCh 26   open drains
Ch 26 open drains
 
Ch 29 hydraulic structures
Ch 29   hydraulic structuresCh 29   hydraulic structures
Ch 29 hydraulic structures
 
Ch 47 hillside drainage
Ch 47   hillside drainageCh 47   hillside drainage
Ch 47 hillside drainage
 
Ch 27 culverts
Ch 27   culvertsCh 27   culverts
Ch 27 culverts
 

Similar to Ch 33 oil separators

IRJET - Removal of Oil Spillage in Marine Environment using Grooved Type Cyli...
IRJET - Removal of Oil Spillage in Marine Environment using Grooved Type Cyli...IRJET - Removal of Oil Spillage in Marine Environment using Grooved Type Cyli...
IRJET - Removal of Oil Spillage in Marine Environment using Grooved Type Cyli...IRJET Journal
 
Archive for the ‘refrigerator commissioning’ tag
Archive for the ‘refrigerator commissioning’ tagArchive for the ‘refrigerator commissioning’ tag
Archive for the ‘refrigerator commissioning’ tagMuhammad Awais
 
Melhorando a limpeza de tanques
Melhorando a limpeza de tanquesMelhorando a limpeza de tanques
Melhorando a limpeza de tanquesRenato Motta
 
Oil mist-eliminator
Oil mist-eliminatorOil mist-eliminator
Oil mist-eliminatoransar baloch
 
Leroi om-rotary-screw-manual
Leroi om-rotary-screw-manualLeroi om-rotary-screw-manual
Leroi om-rotary-screw-manualJasmin Jasmin
 
Current status of fuel technology
Current status of fuel technologyCurrent status of fuel technology
Current status of fuel technologyDhirendra Bihari
 
Assignment 1 - Crude Oil Desalting Unit.pdf
Assignment 1 - Crude Oil Desalting Unit.pdfAssignment 1 - Crude Oil Desalting Unit.pdf
Assignment 1 - Crude Oil Desalting Unit.pdfSafeen Yaseen Ja'far
 
DESIGN CALCULATION FOR EQUIPMENT AND COMPONENTS SPECIFICATION OF LUBRICATING ...
DESIGN CALCULATION FOR EQUIPMENT AND COMPONENTS SPECIFICATION OF LUBRICATING ...DESIGN CALCULATION FOR EQUIPMENT AND COMPONENTS SPECIFICATION OF LUBRICATING ...
DESIGN CALCULATION FOR EQUIPMENT AND COMPONENTS SPECIFICATION OF LUBRICATING ...P singh
 
Hydraulics-fundamentals of hydraulics.ppt
Hydraulics-fundamentals of hydraulics.pptHydraulics-fundamentals of hydraulics.ppt
Hydraulics-fundamentals of hydraulics.pptArbrHalilaj
 
high-Vacuum Transformer Oil Filtration And Dehydration Plants In India-AR ENGG.
high-Vacuum Transformer Oil Filtration And Dehydration Plants In India-AR ENGG.high-Vacuum Transformer Oil Filtration And Dehydration Plants In India-AR ENGG.
high-Vacuum Transformer Oil Filtration And Dehydration Plants In India-AR ENGG.vitika12345
 
high-Vacuum Transformer Oil Filtration And Dehydration Plants In India-AR ENGG.
high-Vacuum Transformer Oil Filtration And Dehydration Plants In India-AR ENGG.high-Vacuum Transformer Oil Filtration And Dehydration Plants In India-AR ENGG.
high-Vacuum Transformer Oil Filtration And Dehydration Plants In India-AR ENGG.vitika12345
 
40266484-Fundamentals-of-Hydraulics.pdf
40266484-Fundamentals-of-Hydraulics.pdf40266484-Fundamentals-of-Hydraulics.pdf
40266484-Fundamentals-of-Hydraulics.pdfVijaySharma983125
 
Maintenance of distillation column asmita
Maintenance of distillation column asmitaMaintenance of distillation column asmita
Maintenance of distillation column asmitaAsmita Mishra
 
sotras filter catalog|sotras cross reference pdf
sotras filter catalog|sotras cross reference pdfsotras filter catalog|sotras cross reference pdf
sotras filter catalog|sotras cross reference pdfdaisy Airmax
 

Similar to Ch 33 oil separators (20)

IRJET - Removal of Oil Spillage in Marine Environment using Grooved Type Cyli...
IRJET - Removal of Oil Spillage in Marine Environment using Grooved Type Cyli...IRJET - Removal of Oil Spillage in Marine Environment using Grooved Type Cyli...
IRJET - Removal of Oil Spillage in Marine Environment using Grooved Type Cyli...
 
Agc wp-selparam
Agc wp-selparamAgc wp-selparam
Agc wp-selparam
 
Archive for the ‘refrigerator commissioning’ tag
Archive for the ‘refrigerator commissioning’ tagArchive for the ‘refrigerator commissioning’ tag
Archive for the ‘refrigerator commissioning’ tag
 
Agc wp-hydroscavprincop
Agc wp-hydroscavprincopAgc wp-hydroscavprincop
Agc wp-hydroscavprincop
 
Melhorando a limpeza de tanques
Melhorando a limpeza de tanquesMelhorando a limpeza de tanques
Melhorando a limpeza de tanques
 
Oil mist-eliminator
Oil mist-eliminatorOil mist-eliminator
Oil mist-eliminator
 
Desing Separators.pdf
Desing Separators.pdfDesing Separators.pdf
Desing Separators.pdf
 
Leroi om-rotary-screw-manual
Leroi om-rotary-screw-manualLeroi om-rotary-screw-manual
Leroi om-rotary-screw-manual
 
Current status of fuel technology
Current status of fuel technologyCurrent status of fuel technology
Current status of fuel technology
 
Assignment 1 - Crude Oil Desalting Unit.pdf
Assignment 1 - Crude Oil Desalting Unit.pdfAssignment 1 - Crude Oil Desalting Unit.pdf
Assignment 1 - Crude Oil Desalting Unit.pdf
 
DESIGN CALCULATION FOR EQUIPMENT AND COMPONENTS SPECIFICATION OF LUBRICATING ...
DESIGN CALCULATION FOR EQUIPMENT AND COMPONENTS SPECIFICATION OF LUBRICATING ...DESIGN CALCULATION FOR EQUIPMENT AND COMPONENTS SPECIFICATION OF LUBRICATING ...
DESIGN CALCULATION FOR EQUIPMENT AND COMPONENTS SPECIFICATION OF LUBRICATING ...
 
Hydraulics-fundamentals of hydraulics.ppt
Hydraulics-fundamentals of hydraulics.pptHydraulics-fundamentals of hydraulics.ppt
Hydraulics-fundamentals of hydraulics.ppt
 
high-Vacuum Transformer Oil Filtration And Dehydration Plants In India-AR ENGG.
high-Vacuum Transformer Oil Filtration And Dehydration Plants In India-AR ENGG.high-Vacuum Transformer Oil Filtration And Dehydration Plants In India-AR ENGG.
high-Vacuum Transformer Oil Filtration And Dehydration Plants In India-AR ENGG.
 
high-Vacuum Transformer Oil Filtration And Dehydration Plants In India-AR ENGG.
high-Vacuum Transformer Oil Filtration And Dehydration Plants In India-AR ENGG.high-Vacuum Transformer Oil Filtration And Dehydration Plants In India-AR ENGG.
high-Vacuum Transformer Oil Filtration And Dehydration Plants In India-AR ENGG.
 
40266484-Fundamentals-of-Hydraulics.pdf
40266484-Fundamentals-of-Hydraulics.pdf40266484-Fundamentals-of-Hydraulics.pdf
40266484-Fundamentals-of-Hydraulics.pdf
 
Lube Oil Purifier.docx
Lube Oil Purifier.docxLube Oil Purifier.docx
Lube Oil Purifier.docx
 
Maintenance of distillation column asmita
Maintenance of distillation column asmitaMaintenance of distillation column asmita
Maintenance of distillation column asmita
 
Presentation marine diesel engines
Presentation  marine diesel enginesPresentation  marine diesel engines
Presentation marine diesel engines
 
MEM’s for HO-EOR evaluation
MEM’s for HO-EOR evaluationMEM’s for HO-EOR evaluation
MEM’s for HO-EOR evaluation
 
sotras filter catalog|sotras cross reference pdf
sotras filter catalog|sotras cross reference pdfsotras filter catalog|sotras cross reference pdf
sotras filter catalog|sotras cross reference pdf
 

More from Fuad Chiwa

The professional interview questions
The professional interview questionsThe professional interview questions
The professional interview questionsFuad Chiwa
 
Ch 48 ww overflows
Ch 48   ww overflowsCh 48   ww overflows
Ch 48 ww overflowsFuad Chiwa
 
Ch 44 subsoil drainage
Ch 44   subsoil drainageCh 44   subsoil drainage
Ch 44 subsoil drainageFuad Chiwa
 
Ch 42 landscaping
Ch 42   landscapingCh 42   landscaping
Ch 42 landscapingFuad Chiwa
 
Ch 41 erosion and sediment control plans
Ch 41   erosion and sediment control plansCh 41   erosion and sediment control plans
Ch 41 erosion and sediment control plansFuad Chiwa
 
Ch 40 contractor activity control
Ch 40   contractor activity controlCh 40   contractor activity control
Ch 40 contractor activity controlFuad Chiwa
 
Ch 38 actions to control erosion sediment
Ch 38   actions to control erosion sedimentCh 38   actions to control erosion sediment
Ch 38 actions to control erosion sedimentFuad Chiwa
 
Ch 37 community education
Ch 37   community educationCh 37   community education
Ch 37 community educationFuad Chiwa
 
Ch 36 housekeeping practices
Ch 36   housekeeping practicesCh 36   housekeeping practices
Ch 36 housekeeping practicesFuad Chiwa
 
Ch 35 ponds and wetlands
Ch 35   ponds and wetlandsCh 35   ponds and wetlands
Ch 35 ponds and wetlandsFuad Chiwa
 
Ch 32 infiltration
Ch 32   infiltrationCh 32   infiltration
Ch 32 infiltrationFuad Chiwa
 
Ch 30 stormwater quality monitoring
Ch 30   stormwater quality monitoringCh 30   stormwater quality monitoring
Ch 30 stormwater quality monitoringFuad Chiwa
 
Ch 25 pipe drains
Ch 25   pipe drainsCh 25   pipe drains
Ch 25 pipe drainsFuad Chiwa
 
Ch 23 roof property drainage
Ch 23   roof property drainageCh 23   roof property drainage
Ch 23 roof property drainageFuad Chiwa
 
Ch 19 on-site detention
Ch 19   on-site detentionCh 19   on-site detention
Ch 19 on-site detentionFuad Chiwa
 
Ch 17 computer models
Ch 17   computer modelsCh 17   computer models
Ch 17 computer modelsFuad Chiwa
 
Ch 15 pollutant estimation
Ch 15   pollutant estimationCh 15   pollutant estimation
Ch 15 pollutant estimationFuad Chiwa
 

More from Fuad Chiwa (17)

The professional interview questions
The professional interview questionsThe professional interview questions
The professional interview questions
 
Ch 48 ww overflows
Ch 48   ww overflowsCh 48   ww overflows
Ch 48 ww overflows
 
Ch 44 subsoil drainage
Ch 44   subsoil drainageCh 44   subsoil drainage
Ch 44 subsoil drainage
 
Ch 42 landscaping
Ch 42   landscapingCh 42   landscaping
Ch 42 landscaping
 
Ch 41 erosion and sediment control plans
Ch 41   erosion and sediment control plansCh 41   erosion and sediment control plans
Ch 41 erosion and sediment control plans
 
Ch 40 contractor activity control
Ch 40   contractor activity controlCh 40   contractor activity control
Ch 40 contractor activity control
 
Ch 38 actions to control erosion sediment
Ch 38   actions to control erosion sedimentCh 38   actions to control erosion sediment
Ch 38 actions to control erosion sediment
 
Ch 37 community education
Ch 37   community educationCh 37   community education
Ch 37 community education
 
Ch 36 housekeeping practices
Ch 36   housekeeping practicesCh 36   housekeeping practices
Ch 36 housekeeping practices
 
Ch 35 ponds and wetlands
Ch 35   ponds and wetlandsCh 35   ponds and wetlands
Ch 35 ponds and wetlands
 
Ch 32 infiltration
Ch 32   infiltrationCh 32   infiltration
Ch 32 infiltration
 
Ch 30 stormwater quality monitoring
Ch 30   stormwater quality monitoringCh 30   stormwater quality monitoring
Ch 30 stormwater quality monitoring
 
Ch 25 pipe drains
Ch 25   pipe drainsCh 25   pipe drains
Ch 25 pipe drains
 
Ch 23 roof property drainage
Ch 23   roof property drainageCh 23   roof property drainage
Ch 23 roof property drainage
 
Ch 19 on-site detention
Ch 19   on-site detentionCh 19   on-site detention
Ch 19 on-site detention
 
Ch 17 computer models
Ch 17   computer modelsCh 17   computer models
Ch 17 computer models
 
Ch 15 pollutant estimation
Ch 15   pollutant estimationCh 15   pollutant estimation
Ch 15 pollutant estimation
 

Recently uploaded

Best VIP Call Girls Noida Sector 47 Call Me: 8448380779
Best VIP Call Girls Noida Sector 47 Call Me: 8448380779Best VIP Call Girls Noida Sector 47 Call Me: 8448380779
Best VIP Call Girls Noida Sector 47 Call Me: 8448380779Delhi Call girls
 
A level Digipak development Presentation
A level Digipak development PresentationA level Digipak development Presentation
A level Digipak development Presentationamedia6
 
VIP Russian Call Girls in Saharanpur Deepika 8250192130 Independent Escort Se...
VIP Russian Call Girls in Saharanpur Deepika 8250192130 Independent Escort Se...VIP Russian Call Girls in Saharanpur Deepika 8250192130 Independent Escort Se...
VIP Russian Call Girls in Saharanpur Deepika 8250192130 Independent Escort Se...Suhani Kapoor
 
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service Bhiwandi
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service BhiwandiVIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service Bhiwandi
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service BhiwandiSuhani Kapoor
 
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130Suhani Kapoor
 
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Service
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts ServiceCall Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Service
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Servicejennyeacort
 
SD_The MATATAG Curriculum Training Design.pptx
SD_The MATATAG Curriculum Training Design.pptxSD_The MATATAG Curriculum Training Design.pptx
SD_The MATATAG Curriculum Training Design.pptxjanettecruzeiro1
 
Abu Dhabi Call Girls O58993O4O2 Call Girls in Abu Dhabi`
Abu Dhabi Call Girls O58993O4O2 Call Girls in Abu Dhabi`Abu Dhabi Call Girls O58993O4O2 Call Girls in Abu Dhabi`
Abu Dhabi Call Girls O58993O4O2 Call Girls in Abu Dhabi`dajasot375
 
NO1 Trending kala jadu Love Marriage Black Magic Punjab Powerful Black Magic ...
NO1 Trending kala jadu Love Marriage Black Magic Punjab Powerful Black Magic ...NO1 Trending kala jadu Love Marriage Black Magic Punjab Powerful Black Magic ...
NO1 Trending kala jadu Love Marriage Black Magic Punjab Powerful Black Magic ...Amil baba
 
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...Amil baba
 
Cheap Rate ➥8448380779 ▻Call Girls In Iffco Chowk Gurgaon
Cheap Rate ➥8448380779 ▻Call Girls In Iffco Chowk GurgaonCheap Rate ➥8448380779 ▻Call Girls In Iffco Chowk Gurgaon
Cheap Rate ➥8448380779 ▻Call Girls In Iffco Chowk GurgaonDelhi Call girls
 
PODSCAPE - Brochure 2023_ prefab homes in Bangalore India
PODSCAPE - Brochure 2023_ prefab homes in Bangalore IndiaPODSCAPE - Brochure 2023_ prefab homes in Bangalore India
PODSCAPE - Brochure 2023_ prefab homes in Bangalore IndiaYathish29
 
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130Suhani Kapoor
 
Kindergarten Assessment Questions Via LessonUp
Kindergarten Assessment Questions Via LessonUpKindergarten Assessment Questions Via LessonUp
Kindergarten Assessment Questions Via LessonUpmainac1
 
call girls in Harsh Vihar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
call girls in Harsh Vihar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️call girls in Harsh Vihar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
call girls in Harsh Vihar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️9953056974 Low Rate Call Girls In Saket, Delhi NCR
 
DragonBall PowerPoint Template for demo.pptx
DragonBall PowerPoint Template for demo.pptxDragonBall PowerPoint Template for demo.pptx
DragonBall PowerPoint Template for demo.pptxmirandajeremy200221
 
Fashion trends before and after covid.pptx
Fashion trends before and after covid.pptxFashion trends before and after covid.pptx
Fashion trends before and after covid.pptxVanshNarang19
 

Recently uploaded (20)

Best VIP Call Girls Noida Sector 47 Call Me: 8448380779
Best VIP Call Girls Noida Sector 47 Call Me: 8448380779Best VIP Call Girls Noida Sector 47 Call Me: 8448380779
Best VIP Call Girls Noida Sector 47 Call Me: 8448380779
 
A level Digipak development Presentation
A level Digipak development PresentationA level Digipak development Presentation
A level Digipak development Presentation
 
VIP Russian Call Girls in Saharanpur Deepika 8250192130 Independent Escort Se...
VIP Russian Call Girls in Saharanpur Deepika 8250192130 Independent Escort Se...VIP Russian Call Girls in Saharanpur Deepika 8250192130 Independent Escort Se...
VIP Russian Call Girls in Saharanpur Deepika 8250192130 Independent Escort Se...
 
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service Bhiwandi
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service BhiwandiVIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service Bhiwandi
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service Bhiwandi
 
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130
 
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Service
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts ServiceCall Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Service
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Service
 
SD_The MATATAG Curriculum Training Design.pptx
SD_The MATATAG Curriculum Training Design.pptxSD_The MATATAG Curriculum Training Design.pptx
SD_The MATATAG Curriculum Training Design.pptx
 
Abu Dhabi Call Girls O58993O4O2 Call Girls in Abu Dhabi`
Abu Dhabi Call Girls O58993O4O2 Call Girls in Abu Dhabi`Abu Dhabi Call Girls O58993O4O2 Call Girls in Abu Dhabi`
Abu Dhabi Call Girls O58993O4O2 Call Girls in Abu Dhabi`
 
NO1 Trending kala jadu Love Marriage Black Magic Punjab Powerful Black Magic ...
NO1 Trending kala jadu Love Marriage Black Magic Punjab Powerful Black Magic ...NO1 Trending kala jadu Love Marriage Black Magic Punjab Powerful Black Magic ...
NO1 Trending kala jadu Love Marriage Black Magic Punjab Powerful Black Magic ...
 
escort service sasti (*~Call Girls in Prasad Nagar Metro❤️9953056974
escort service sasti (*~Call Girls in Prasad Nagar Metro❤️9953056974escort service sasti (*~Call Girls in Prasad Nagar Metro❤️9953056974
escort service sasti (*~Call Girls in Prasad Nagar Metro❤️9953056974
 
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...
 
Cheap Rate ➥8448380779 ▻Call Girls In Iffco Chowk Gurgaon
Cheap Rate ➥8448380779 ▻Call Girls In Iffco Chowk GurgaonCheap Rate ➥8448380779 ▻Call Girls In Iffco Chowk Gurgaon
Cheap Rate ➥8448380779 ▻Call Girls In Iffco Chowk Gurgaon
 
PODSCAPE - Brochure 2023_ prefab homes in Bangalore India
PODSCAPE - Brochure 2023_ prefab homes in Bangalore IndiaPODSCAPE - Brochure 2023_ prefab homes in Bangalore India
PODSCAPE - Brochure 2023_ prefab homes in Bangalore India
 
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130
 
Kindergarten Assessment Questions Via LessonUp
Kindergarten Assessment Questions Via LessonUpKindergarten Assessment Questions Via LessonUp
Kindergarten Assessment Questions Via LessonUp
 
call girls in Harsh Vihar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
call girls in Harsh Vihar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️call girls in Harsh Vihar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
call girls in Harsh Vihar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
 
DragonBall PowerPoint Template for demo.pptx
DragonBall PowerPoint Template for demo.pptxDragonBall PowerPoint Template for demo.pptx
DragonBall PowerPoint Template for demo.pptx
 
young call girls in Vivek Vihar🔝 9953056974 🔝 Delhi escort Service
young call girls in Vivek Vihar🔝 9953056974 🔝 Delhi escort Serviceyoung call girls in Vivek Vihar🔝 9953056974 🔝 Delhi escort Service
young call girls in Vivek Vihar🔝 9953056974 🔝 Delhi escort Service
 
Call Girls Service Mukherjee Nagar @9999965857 Delhi 🫦 No Advance VVIP 🍎 SER...
Call Girls Service Mukherjee Nagar @9999965857 Delhi 🫦 No Advance  VVIP 🍎 SER...Call Girls Service Mukherjee Nagar @9999965857 Delhi 🫦 No Advance  VVIP 🍎 SER...
Call Girls Service Mukherjee Nagar @9999965857 Delhi 🫦 No Advance VVIP 🍎 SER...
 
Fashion trends before and after covid.pptx
Fashion trends before and after covid.pptxFashion trends before and after covid.pptx
Fashion trends before and after covid.pptx
 

Ch 33 oil separators

  • 1. 33 OIL SEPARATORS 33.1 INTRODUCTION ............................................................................................................. 33-1 33.1.1 33.1.2 Types of Separator............................................................................................ 33-1 33.1.3 33.2 Application and Purpose .................................................................................... 33-1 Flow Configuration ............................................................................................ 33-2 DESIGN AND SIZING...................................................................................................... 33-3 33.2.1 33.2.2 Degree of Treatment......................................................................................... 33-3 33.2.3 Design Flow Rate .............................................................................................. 33-3 33.2.4 Flow Balancing Storage Volume......................................................................... 33-4 33.2.5 API (American Petroleum Institute) Tank Sizing ................................................. 33-4 33.2.6 Plate Separator Sizing ....................................................................................... 33-4 33.2.7 33.3 Design .............................................................................................................. 33-3 Flow Control Device .......................................................................................... 33-4 OTHER DESIGN CONSIDERATIONS................................................................................. 33-5 33.3.1 33.3.2 33.4 Oil Retention Baffles.......................................................................................... 33-5 Flow Spreading Baffles...................................................................................... 33-5 MAINTENANCE ............................................................................................................... 33-5 APPENDIX 33.A WORKED EXAMPLE ........................................................................................... 33-7 Urban Stormwater Management Manual 33-i
  • 2.
  • 3. Oil Separators 33.1 More relevant applications are for : INTRODUCTION • Oil separation devices are applicable for stormwater runoff from areas where hydrocarbon products are handled or where small spills routinely fall on paved surfaces exposed to rain. The objective of the oil separators is to treat most of the flow (90 to 95%) from a potentially contaminated catchment to an acceptable degree (10 – 20 mg/l oil and grease) and to remove free floating oil. In addition to collecting oil, which rises to the surface, separators collect sediment, which falls to the bottom of the devices. In fact, the sediment is likely to contain petroleum products, which are attached to fine sediments. Oil separation devices sized in accordance with the guidelines in this Chapter will achieve a sufficient degree of sedimentation so further sedimentation devices would not be required. Oil in general urban stormwater runoff is likely to be in the form of an emulsion, which is intimately mixed with the water. Such oil will not readily float out, so oil separators are not used for treatment of general urban runoff. Oil separators need to treat only the stormwater runoff from oily areas or areas which may become oily. General stormwater runoff from other areas should be routed away from the separator and treated for sediment removal in the usual fashion. Treatment should be as close to the source of the oil-generating activities as possible. High rates of runoff and practical limitations on the treatment process mean that oil separators can only be used for small catchment areas. For Malaysian conditions the practical maximum catchment area that can be treated is in the order of 1000 m2 ( 0.1 hectare). Figure 33.1 Urban Stormwater Management Manual service stations, • 33.1.1 Application and Purpose yards where petroleum products are stored or handled, or vehicles are serviced, and • heavily used highway parking lots. The potential also exists to use separators (and in particular, the balancing storage) for containment of accidental oil spills, in addition to their primary function of treatment. Spills will enter the separator via the site drainage system and mix with the water in the separator, then the oil in the spill will rise to the surface. If the separator is to be used for spill containment, it should be ensured that the separator can hold the anticipated spill volume. Additional storage may be required. 33.1.2 Types of Separator API tanks (see Figure 33.1) and plate separators are the more efficient oil separators. API tanks were originally designed by the American Petroleum Institute (API) for use in refinery applications, but modifications of the design can be used for stormwater treatment. Plate separators (see Figure 33.2) contain packs of plates, typically spaced at 10 mm to 20 mm centres. The plates increase the effective surface of the device. Viewed another way, the close spacing of the plates reduces the height that an oil droplet must rise before it reaches a collecting surface. Therefore, to achieve the same degree of treatment as an API tank, a much smaller device can be used. This will result in less land area being taken up and less excavation, which will more often than not compensate for the higher cost of the plate packs. Plate separators are often supplied by manufacturers as proprietary devices. Schematic of API Separator 33-1
  • 4. Oil Separators recommended configuration is shown schematically in Figure 33.3. (a) Flow balancing A storage tank is provided upstream of the separator to reduce the peak inflow rate to that which the separator can handle. The stored runoff is treated slowly through the separator in the period between storms. The flow rate through the separator is then more even or ‘balanced’. Figure 33.2 Schematic of Plate Separator (Meyers, 1980) 33.1.3 Flow Configuration Oil separators, which receive stormwater runoff, should be installed with a high flow bypass and flow balancing, unless special circumstances make it impractical. The high flow bypass diverts excess flows away from the separator, ensuring that it is not overloaded. Flow balancing uses storage to reduce the peak inflow rate and increase the efficiency of the separator. The Figure 33.3 33-2 In large storms, the storage area may fill completely, in which case some flow is bypassed without treatment. The storage area may consist of a tank or bunded area. The potential also exists to use the storage area for containment of fuel spills. (b) High-flow Bypass The bypass configuration is also shown in Figure 33.3. The bypass begins to operate when the balancing storage becomes full. At this stage the water level in the bypass is at the bypass weir level and the flow through the separator is controlled hydraulically to Qd (the separator design flow). Careful hydraulic design is necessary to achieve this condition. Oil Separator with Bypass and Flow Balancing Urban Stormwater Management Manual
  • 5. Oil Separators Usually flow throttling will be at the outlet of the tank because if the flow constriction orifice were at the inlet, the oil may become emulsified. Furthermore, an orifice at the outlet is less likely to clog. A non-emulsifying (e.g. diaphragm) pump may be used instead of flow throttling to control the flow rate to the separator. The bypass weir should be long enough to pass the maximum design flow in the incoming pipe while keeping the flow to the separator small enough to ensure that oil re-entrainment does not occur. 33.2 DESIGN AND SIZING 33.2.1 Design Oil separators shall be divided into three compartments by baffles or berms: a forebay (inlet chamber), an oil separator cell, and an afterbay (outlet chamber). The forebay is primarily to trap and collect sediments, encourage plug flow and reduce turbulence. The oil separator cell is to trap and hold oil. The afterbay provides a relatively oil-free exit cell from the outlet. The length of the forebay shall be approximately 1/3 of the total length of the three cells (see Figure 33.1). The oilretaining baffle shall be located approximately 1/4 of the total length of the three cells from the outlet wall. greater than 150 µm in diameter (Washington State Department of Ecology, 1990). Traditionally, 150 µm separation has been used overseas, which typically results in an effluent oil and grease concentration of 50 – 100 mg/l (Meyers, 1980). Typically standards for industrial discharges in Australia are 10-20 mg/l, which generally corresponds to the removal of droplets larger than 60 µm (Meyers, 1980). Separation of the 60 µm droplet was adopted as the basis for design for devices in Australia and New Zealand; this figure corresponds to the lower tail of the droplet size distribution and should result in an effluent quality of 10 - 20 mg/l at the design flow. The rise velocity for a 60 µm droplet can be calculated, given the water temperature (which affects the viscosity of the water) and the density of the oil. This rise velocity is then used in the sizing calculations for the device. The rise velocity may be calculated according to: Vr = • • (a) What level of treatment is achieved for flow, which is passed through the separator? In other words, what is the design level of treatment at the design flow rate? What fraction of the runoff from the catchment is passed through the separator ? A higher flow capacity of the separator or a larger flow balancing area will result in more flow being treated. Design Level of Treatment at Design Flow Rate Grease and oil, which is not emulsified, dissolved or attached to sediment, will be present as oil droplets or as a surface slick. If only large droplets can be removed, then small droplets will pass through the device and into the receiving water body. If small droplets can be removed, then effluent quality will be improved (at the expense of requiring a slower passage of stormwater through the device, because smaller droplets rise more slowly). No data are available on the size distribution of oil droplets in stormwater from commercial or industrial areas, but some overseas data are available for petroleum product storage terminals. These data indicate that about 80% of droplets (by volume) are greater than 90 µm and 30% are Urban Stormwater Management Manual (33.1) where s = specific gravity of the oil, D = the droplet diameter (m), υ = kinematic viscosity of water, and g = gravitational acceleration (9.8 m/s2). 33.2.2 Degree of Treatment The degree of treatment achieved by the separator system depends on two factors: g D 2 (1 − s ) 18υ At 15°C and for an oil specific gravity of 0.9, the rise velocity of a 60 µm droplet using Equation 33.1 is 0.62 m/hr and this is the recommended design value for most situations. (b) Fraction of Runoff Treated The objective is to treat 90% to 95% of the runoff from the catchment on a long term basis (not for each and every rain event). The choice of the degree of treatment is based on rainfall analysis, as discussed in Chapter 13. This degree of treatment leads to a required separator flow capacity, and possibly a requirement for flow balancing storage. 33.2.3 Design Flow Rate The required design flow rate is that from the water quality design storm (see Chapter 4). This 3 month ARI flow (and smaller flows) should be passed through the flow balancing storage and the device, and flows in excess of this amount are bypassed. This means that only 5% - 10% of the flow is bypassed (on a long term basis, not for each flow event). The peak design inflow rate can be computed using the Rational Method or hydrograph methods, as described in Chapter 14. 33-3
  • 6. Oil Separators Table 33.1 For service stations, the catchment area should include an allowance for rain, which manages to get under the canopy. In some cases washout water from under the canopy areas in service stations, or spill-down water from open paved areas, will be passed to the separator. It is unlikely that wash-down and heavy rain will occur at the same time, so it is not necessary to add the wash-down flow to the stormwater runoff flow. Rather, the maximum of the stormwater runoff flow and the wash-down flow can be used to size the separator. That is, if the wash-down flow is larger that the calculated peak inflow, then use the wash-down flow as the design flow. U /Vr 15 33.2.5 API (American Petroleum Institute) Tank Sizing The horizontal velocity U in the tank is calculated as: (33.2) where d = tank depth and W = tank width F Qd Vr (33.3) Based on plug flow, the above relationship ensures that a droplet with rise velocity Vr will rise to the surface during its passage through the tank. The required rise velocity is the rise velocity of a 60 µm oil droplet (see Section 33.2.2(a)), which for a temperature of 15°C and an oil specific gravity of 0.9, is 0.62 m/hr. The dimensionless factor F accounts for short-circuiting and turbulence effects, which degrade the performance of the tank. This factor depends on the ratio of horizontal velocity (U) to rise velocity (Vr), as shown in Table 33.1. The volume and area determined from this tank sizing refer to the dimensions of the main compartment of the tank. Additional volume should be allowed for inlet and outlet sections in the tank. 33-4 1.52 6 1.37 3 1.28 • U ≤ 15 Vr • 0.3 W ≤ d ≤ 0.5 W • 2m<W<5m • 1 m < d < 2.5 m where d is the depth and W is the width of the tank. Some of these dimensions will not be appropriate for smaller catchments and may need to be relaxed. To avoid re-entrainment and degradation of performance, it is required that the maximum horizontal flow velocity in the main part of the tank be less than 25 m/hr (when the bypass is operating at the maximum flow). 33.2.6 Plate Separator Sizing The plan area (Ad) for the separator cell is based on the rise velocity (Vr) and design flow rate (Qd), according to the formula: Ad = 1.64 10 The required volume of the flow-balancing compartment depends on the design storm runoff rate and volume and the treatment rate of a separator. The calculation of the balancing volume is done by storage routing, as described in Chapter 14. A worked example is given in Appendix 33.A (ii). Qd d ×W F Factor Other dimensional requirements (from American Petroleum Institute, 1969) are: 33.2.4 Flow Balancing Storage Volume U = F Factor for API Separators A flowchart for the sizing of an API plate separator is given in Figure 33.4. Plate separators are available from several suppliers. The suppliers will be able to provide an appropriate size of device to achieve 60 µm droplet separation at the chosen design flow rate (Qd). The required effective area can be calculated from: AE = Qd Vr (33.4) where AE = effective area Some increase in the calculated size should be allowed, to account for short-circuiting. 33.2.7 Flow Control Device (a) Orifice Sizing (Inlet pipe to separator) For a round orifice plate flowing full, with head (h), the area of the orifice is estimated from: Urban Stormwater Management Manual
  • 7. Oil Separators Ao = Qd 0.6 2 gh (33.5) where Qd = the design flow (m3/s), A0 = area of the orifice (m2), g = gravitational acceleration (m/s2), and h = head (m). Other means of throttling the inlet may be used, with design based on the appropriate head loss formula. As an alternative to hydraulic flow control a non-emulsifying pump may be used to control the flow rate. The recommended orifice sizing procedure is as follows: 1. Choose an orifice diameter and calculate the orifice area. Consideration should be given to the risk of blockage. 2. Calculate the water level in the bypass when the design flow, Qd is being passed through the separator. Set the bypass weir at this level. 3. Calculate the head over the bypass weir (hw) (using an assumed weir length) when the weir is passing Qw , the maximum flood flow to go over the bypass. A standard weir equation may be used to calculate this head. 4. Calculate the flow through the separator when the bypass weir is passing Qw. If this flow is larger than the maximum allowed flow through the separator, then either increase the bypass weir length and return to Step 3, or reduce the orifice area and return to Step 1. The maximum allowed flow for a plate separator is 2 times Qd while the maximum allowed flow for an API tank is the flow corresponding to a horizontal velocity of 25 m/hr. An outlet baffle extending from the surface down is required to stop trapped oil from passing over the outlet weir. 33.3.2 Flow Spreading Baffles To achieve even flow distribution across tanks at the inlet, baffled inlet ports or other devices are used. API (1969) recommended slotted inlet baffles, while other devices such as those used in settling tanks in wastewater treatment plants may be used. The sizing of the inlet ports or baffles should be such that some head loss is provided (to spread flow), but it is recommended that velocities should be less than 0.5 m/s, at the maximum separator flow to avoid oil emulsification. 33.4 MAINTENANCE With any oil separation device maintenance is essential. Oil and solids build up to such a degree that gross reentrainment of captured pollutants occurs. The devices are then ineffective. For this reason, maintenance schedules must be submitted with the permit application. Oil Removal – The separator should be inspected periodically and frequently to determine the amount of oil collected. Oil should be removed if necessary (by pumping or decanting). For automatic oil skimming systems, checks can be less frequent, since, if the oil outlet device is working properly, oil should not collect to a great depth. Oil will usually be decanted or pumped to a storage tank or barrel, which should be checked periodically. If the tank or barrel is full, the oil should be removed for re-refining or disposal. In some situations it may be desirable to use flow throttling at the inlet to the tank rather than at the outlet. In this situation there would be less variation of water level in the tank (which is beneficial for oil skimming) but there would be larger velocities at the inlet (which may cause oil emulsification). To avoid emulsification, it is recommended that flow velocities through an inlet flow control orifice be limited to less than 0.5 m/s. Oil Absorbing Pads – Pads (if used) should be checked and replaced if they are saturated. The used pads should be disposed of in an appropriate manner. 33.3 Removal of Sediment – The slurry at the bottom of the tank should be removed periodically and disposed of. Sediment removal from the bypass may be required as well. Sediment should also be removed from the flow balancing compartment (if used). OTHER DESIGN CONSIDERATIONS 33.3.1 Oil Retention Baffles An inlet baffle is required so that oil collected in the tank does not pass back into the bypass and over the bypass weir. The baffle may consist of a wall extending down from the surface. Alternatively, an inverted elbow, or preferably a tee (to make cleaning easier), may be attached to the inlet pipe as shown in Figure 33.1. The tee extends down below the oil level so oil will not pass back into the bypass. Urban Stormwater Management Manual Oil Skimmer Operation – The bypass should be checked to determine whether oil is collecting in the bypass. If so, the oil should be removed and modifications to the pipe between the bypass and separator should be considered. Cleaning of Screens – Screens, which remove debris or protect the flow control orifice (if used) should be cleaned regularly. Clearing of Orifices – Orifices and inlet pipes should be checked regularly for clogging and should be unplugged if 33-5
  • 8. Oil Separators necessary. If clogging is a persistent problem, then further screening should be used. separator is not operating. It should be compared with the design value and the weirs adjusted if necessary. Weir Levels – A check should be made of the elevation of the bypass weir with respect to the water level when the Access – Easily removed covers and easily accessed screens and orifices should be used. This will ensure ease of maintenance. See Chapter 14. Hydrograph methods are required for calculation of storage 1. Calculate inflow hydrograph 2. Choose separator design flow Qd Consult the manufacturer's recommendations 3. Choose d and W/d for separator 4. Calculate Vr and U No 5. U<25mm/hr and U/Vr<15 ? No Equations 33.1 and 33.2 Refer to Section 33.2.4 Yes 6. Determine F and Ls 7. Is oil separator size reasonable ? Consider site constraints Yes 8. Determine separator dimensions Lr , Ls , La Figure 33.4 33-6 9. Determine flow balancing requirements Flow Chart for Sizing of API Oil Separator Urban Stormwater Management Manual
  • 9. Subject Index APPENDIX 33.A WORKED EXAMPLE A service station is fitted with an oil separator. The layout is shown in Figure 33.A1. Runoff from unpaved areas, the covered forecourt, and areas unlikely to be contaminated with oil is routed away from the separator. This leaves a paved oily surface of 300m2 draining to the oil separator. The wash-down water from the carwash is routed to the sanitary sewer. Figure 33.A1 API Tank Design for Example Service Station Step 1. Design Flow C = 0.9 for impervious area A = 300 m2 tc = 5 min (assumed) I5 for 3 month ARI and tc of 5 min = 120mm/hr Qpeak = = CIA 360 (Equation 14.7, see Chapter 14). (0.9 x 120 x 0.03) = 0.009 m3/s = 32.4 m3/hr 360 Urban Stormwater Management Manual 7
  • 10. Oil Separators Step 2 From the manufacturer’s advice, the design flowrate Qd = 5 m3/hr Step 3. Trial sizing of oil separator Try d = 1.0 m and W=2.5 m Step 4 For design flowrate Qd = 5 m3/hr U =Q/(d.W) = 5/(1.0 x 2.5) = 2 m/hr (Equation 33.2) For a design particle size of 60 µm or larger oil droplets, Vr = 0.62 m/hr (Equation 33.1) U/Vr = 2 = 3.23 0.62 Step 5 The trial design complies with velocity limits, so it is accepted. Step 6 From Table 33.1, F = 1.28 Plan area of API separator cell Ad = 5 x 1.28 = 10.3 m2 hr (Equation 33.3) 0.62 Length of separator cell Ls = Ad /W Ls = 10.3/2.5 =4.12 m Step 7 The trial design is considered to be acceptable as it meets site constraints. Step 8 Total length of separator L (refer Figure 33.1): L = Lf + Ls +La L = L/3 + 4.12 + L/4 (1 – 0.33 – 0.25) x L = 4.12 L = 9.8 m, say 10 m overall Step 9. Calculation for Flow Balancing (i) The critical design storm for storage will be longer than the calculated tc. Try a series of different durations. Trial t = 20 min (assumed) Qpeak = = (ii) 33-8 CIA 360 I5 for 3 month ARI and tc of 20 min = 94.13 mm/hr (Equation 14.7, see Chapter 14). (0.9 x 94.13 x 0.03) = 0.0071 m3/s 360 The storage routing calculation for flow balancing is shown in the following table. Urban Stormwater Management Manual
  • 11. Subject Index Table 33.A1 Cumulative Time (min) Routing Calculation for Flow Balancing Storage Inflow Inflow Volume Outflow (m3/s) (m3) (m3/hr) Outflow Volume (m3) Cumulative Storage (m3) 0 0 2.5 0.0035 0.263 5 0.104 0.159 5 0.0071 0.795 5 0.208 0.746 7.5 0.0071 1.065 5 0.208 1.603 10 0.0071 1.065 5 0.208 2.460 12.5 0.0071 1.065 5 0.208 3.317 15 0.0071 1.065 5 0.208 4.174 17.5 0.0071 1.065 5 0.208 5.031 20 1.065 5 0.208 5.888 0.0035 0.795 5 0.208 6.475 25 (iii) 0.0071 22.5 0 0.263 5 0.208 6.530 Repeat the calculation for storm durations of 30 min, 45 min, 60 min, etc. These calculations give the following results: Storm Duration (min) Cumulative Storage (m3) 20 6.53 30 6.69 45 6.99 60 6.67 90 5.41 120 3.71 The critical storm duration (that which gives the largest storage requirement) for the balancing storage is 45 minutes and the volume required for flow balancing = 7 m3 Urban Stormwater Management Manual 9