SlideShare a Scribd company logo
1 of 27
Advanced methods for
sampling and analysis of
post-tensioned concrete
tendon greases
Rich Wurzbach
ASNT Level III, Infrared and Thermal Testing
Laboratory Lubricant Analyst (LLA-I)
MRG Labs, York, Pennsylvania, USA
Overview
 Background of tendon grease testing
 Failures of post-tension tendons
 Comparison of as-found conditions,
failures, to routine grease testing
 Root-Cause failure analysis and corrective
actions
 Enhanced sampling methods
 Expanded grease analysis techniques
Background
 Some nuclear containment designs
include ungrouted post-tension concrete
tendons
 Tendon sheaths and anchorhead areas
are filled with a corrosion protection
grease
 ASME Section XI, IWL-2525 Table 1
contains guidance for corrosion protection
grease testing, requires 125g sample
minimum
Table IWL-2525-1
Status of referenced tests
 ASTM D992 was withdrawn in 1983
 Current version of ASTM D4327 allows for
testing of all three ions, but IWL-2525-1
specifies this for nitrates only, requires two other
tests to be performed.
 APHA tests are for environmental and
wastewater; often requires samples being split
between labs, or being run by inexperienced
personnel, may require refrigeration of prepared
sample
 Total alkalinity test does not fall within the scope
of current ASTM standard.
Sampling Challenges
 Quantity required for current IWL-2525
test slate requires disassembly of tendon
anchors can, disturbing anchor area
during sampling
 Harvesting of grease may disturb position
of buttonheads, hiding broken strand
indications
 Invasive nature of sampling requires costly
logistical support, equipment, time,
scaffold, etc.
Tendon Anchor and Can
Containment Tendon Grease
 Tendon failure at US
nuclear power plant
prompts RCFA, CAR
 IWL, Section IX
requires 125g grease
 Test slate for 2 grams
grease developed; tool
for sampling remotely
Grease thief and T-handle
 Provide method to sample grease near anchor without
disassembly
 Design consistent with ASTM D7718 Standard
Practice for Obtaining In-Service Samples of
Lubricating Grease
 T-handle and stinger probe allow sampling grease
from face of anchor
 Results from Small Volume Test (SVT) correlated to
disassembly method (large volume sample)
 Sampling saved ~US$500,000 in maintenance costs
Water – D95 (IWL-2525)
 Uses distillation glassware
 Per ASTM: “The amount of water as determined
by this test method…to the nearest 0.05 or 0.1
volume%”, which is 500-1000ppm. 
 Per Noria Training: D95 “is fairly cumbersome
and requires a comparatively large sample to
ensure accuracy, which is why it is rarely used in
production-style oil analysis labs today”
Water – Karl Fischer (SVT)
 Per ASTM: KF allows “direct determination
of water in the range of 10 to 25,000” ppm
 Can be performed on grease via “oven
method” to eliminate interferences and
improve accuracy
 Only a small volume of grease required
(about ¼ gram)
Water Testing Comparison
Image courtesy Noria Corporation, USA Images courtesy Metrohm USA
SVT
IWL
Total Alkalinity Testing
 Uses an “ASTM Modified” procedure.
 Per ASTM: “determination of acidic or basic
constituents in petroleum products and
lubricants soluble or nearly soluble in mixtures
of toluene and isopropyl alcohol.”
 Per ASTM: “This test method is not suitable
for measuring the basic constituents of many
basic additive-type lubricating oils. Test
Method D4739 can be used for this purpose.”
Visconorust contains basic detergents
Total Alkalinty Comparison
 Method developed using 0.5 grams
grease and smaller solvent amount
 Grease fully dissolves, acidification
process followed
 Titration performed with both colorimetric
and potentiometric (D4793) methods,
correlating results
 Titration performed per IWL-2525 and new
small volume method, correlating results
Ion testing
 Two of three methods in IWL-2525 allow
for ion-specific electrodes
 New method for small volume ion-specific
electrode method under development
 Can create more repeatable, reliable, and
quicker test for ions, Chloride, Nitrate and
Sulfide
SVT Small Volume Test Slate
 Ferromagnetic Iron (ppm) – tested with a Hall-effect
sensor
 Metals spectroscopy – multiple elements, ppm (iron,
calcium, etc)
 Moisture, ppm
 Total Base Number (alkalinity) – using 0.5g sample
 Red oxide count (corrosion particulate by microscope or
direct-imaging sensor
 Die Extrusion Index – evaluating unexpected softening or
hardening of the grease
 Microbial content – quantification of ATP by grease thin-
film extraction
Analysis Techniques
Sample is received. fdM+ is run Grease Thief Analyzer is performed and substrate is made
Two strips are used to make
a dilution to run RDE/ICP.
One Strip is used
for FT-IR.
One Strip is Dissolved in Green
RULER solution to run RULER.
Ferrographic analysis and Red
Oxide quantification
Results
 Data compiled for 500 tendon locations
 Strongest correlation between related
parameters (Calcium and TBN, Red
Oxides and Ferrous Debris)
 Some high Red Oxides were found in
higher Total Alkalinity locations
 Multiple potential failure modes likely
contributor to lack of consistent correlation
Results
Results
Results
Results
Analysis of Data
 Not a clear single failure mode
represented by correlated data
 Several tendons identified for further
testing: high ATP (microbial), several high
Red Oxides, & high Red Oxide/Low TBN
 Testing showed majority of tendons in
good condition, small percentage
candidates for disassembly and inspection
 Advanced statistics package used for
ranking metrics
Analysis of Data
 Dispersion analysis: failed tendon
exceeded 2σ outside the mean for the
failed tendon for three parameters
Data analysis by Dr. David Polk, Polk-Lepson Research, USA http://www.polk-lepsonresearchgroup.com/
Analysis of Data
 Regression analysis performed using Red
Oxides as the dependent variable (actual
measure of corrosion) and assigning
weighting factors for scoring
 Failed tendon and one other scored 5, and
twelve others scored as 4.
Data analysis by Dr. David Polk, Polk-Lepson Research, USA http://www.polk-lepsonresearchgroup.com/
Summary
 Tendon failure modes require reliable and
cost-effective method for sampling and
analysis
 Using new sampling tools per ASTM
D7718 without tendon can removal
 Small volume testing methods shown to
be equivalent or superior to traditional
testing
 Additional failure modes detectable with
small volume test slate

More Related Content

What's hot

Iron-SGS Report.PDF
Iron-SGS Report.PDFIron-SGS Report.PDF
Iron-SGS Report.PDF
琼 刘
 
Kukuh Soerowidjojo - Experience of Qualification Test of CRA Material
Kukuh Soerowidjojo - Experience of Qualification Test of CRA MaterialKukuh Soerowidjojo - Experience of Qualification Test of CRA Material
Kukuh Soerowidjojo - Experience of Qualification Test of CRA Material
Kukuh Wanengkirtyo
 
SpeedVac SPD1010 Concentrator
SpeedVac SPD1010 ConcentratorSpeedVac SPD1010 Concentrator
SpeedVac SPD1010 Concentrator
Jiarong Zhou
 

What's hot (19)

Optimizing solid core_30955
Optimizing solid core_30955Optimizing solid core_30955
Optimizing solid core_30955
 
Understanding the Issues Affecting the Accuracy of Measuring Oxygen Consumpti...
Understanding the Issues Affecting the Accuracy of Measuring Oxygen Consumpti...Understanding the Issues Affecting the Accuracy of Measuring Oxygen Consumpti...
Understanding the Issues Affecting the Accuracy of Measuring Oxygen Consumpti...
 
ReactIR as a Diagnostic Tool for Developing Robust, Scalable Synthetic Processes
ReactIR as a Diagnostic Tool for Developing Robust, Scalable Synthetic ProcessesReactIR as a Diagnostic Tool for Developing Robust, Scalable Synthetic Processes
ReactIR as a Diagnostic Tool for Developing Robust, Scalable Synthetic Processes
 
Chromatography: Complete Inorganic Elemental Speciation Analysis Solutions fo...
Chromatography: Complete Inorganic Elemental Speciation Analysis Solutions fo...Chromatography: Complete Inorganic Elemental Speciation Analysis Solutions fo...
Chromatography: Complete Inorganic Elemental Speciation Analysis Solutions fo...
 
Materials, Corrosion and Flow Assurance Services
Materials, Corrosion and Flow Assurance ServicesMaterials, Corrosion and Flow Assurance Services
Materials, Corrosion and Flow Assurance Services
 
Automated Analysis of Explosives in Soil Samples
Automated Analysis of Explosives in Soil SamplesAutomated Analysis of Explosives in Soil Samples
Automated Analysis of Explosives in Soil Samples
 
Revisions to EPA Method 624 for Analysis of VOCs by GCMS
Revisions to EPA Method 624 for Analysis of VOCs by GCMSRevisions to EPA Method 624 for Analysis of VOCs by GCMS
Revisions to EPA Method 624 for Analysis of VOCs by GCMS
 
Iron-SGS Report.PDF
Iron-SGS Report.PDFIron-SGS Report.PDF
Iron-SGS Report.PDF
 
Kukuh Soerowidjojo - Experience of Qualification Test of CRA Material
Kukuh Soerowidjojo - Experience of Qualification Test of CRA MaterialKukuh Soerowidjojo - Experience of Qualification Test of CRA Material
Kukuh Soerowidjojo - Experience of Qualification Test of CRA Material
 
New High-quality, Cost-Efficient Headspace GC Autosampler
New High-quality, Cost-Efficient Headspace GC AutosamplerNew High-quality, Cost-Efficient Headspace GC Autosampler
New High-quality, Cost-Efficient Headspace GC Autosampler
 
Containment Filtered Venting - A new approach
Containment Filtered Venting - A new approachContainment Filtered Venting - A new approach
Containment Filtered Venting - A new approach
 
SpeedVac SPD1010 Concentrator
SpeedVac SPD1010 ConcentratorSpeedVac SPD1010 Concentrator
SpeedVac SPD1010 Concentrator
 
Chromatography: Meeting the Challenges of EU regulations with up-to-date Conf...
Chromatography: Meeting the Challenges of EU regulations with up-to-date Conf...Chromatography: Meeting the Challenges of EU regulations with up-to-date Conf...
Chromatography: Meeting the Challenges of EU regulations with up-to-date Conf...
 
Use of Solid Core Chromatography for the Analysis of Pharmaceutical Compounds
Use of Solid Core Chromatography for the Analysis of Pharmaceutical CompoundsUse of Solid Core Chromatography for the Analysis of Pharmaceutical Compounds
Use of Solid Core Chromatography for the Analysis of Pharmaceutical Compounds
 
Chromatography: Anions and Metals Analysis for Waters Impacted by Hydraulic F...
Chromatography: Anions and Metals Analysis for Waters Impacted by Hydraulic F...Chromatography: Anions and Metals Analysis for Waters Impacted by Hydraulic F...
Chromatography: Anions and Metals Analysis for Waters Impacted by Hydraulic F...
 
Cwea Me Hg Presentation Er
Cwea Me Hg Presentation ErCwea Me Hg Presentation Er
Cwea Me Hg Presentation Er
 
Next Generation Ultra High Pressure Liquid Chromatography (UHPLC) Technologie...
Next Generation Ultra High Pressure Liquid Chromatography (UHPLC) Technologie...Next Generation Ultra High Pressure Liquid Chromatography (UHPLC) Technologie...
Next Generation Ultra High Pressure Liquid Chromatography (UHPLC) Technologie...
 
Separate Your Science LC tour introduction
Separate Your Science LC tour introductionSeparate Your Science LC tour introduction
Separate Your Science LC tour introduction
 
Determination of Carbohydrates in Various Matrices by Capillary High-Performa...
Determination of Carbohydrates in Various Matrices by Capillary High-Performa...Determination of Carbohydrates in Various Matrices by Capillary High-Performa...
Determination of Carbohydrates in Various Matrices by Capillary High-Performa...
 

Similar to Concrete Containment Tendon Grease Sampling and Analysis

Optimized maspi pama april 2009 rev1 pomer point
Optimized maspi pama april 2009 rev1 pomer pointOptimized maspi pama april 2009 rev1 pomer point
Optimized maspi pama april 2009 rev1 pomer point
bocah666
 
Jop description for Senior lab chemist ( shift leader)
Jop description for Senior lab chemist ( shift leader)Jop description for Senior lab chemist ( shift leader)
Jop description for Senior lab chemist ( shift leader)
Haytham Aly
 
Haytham CV 2015 final October
Haytham CV 2015 final OctoberHaytham CV 2015 final October
Haytham CV 2015 final October
Haytham Aly
 
EricKatzen_NEEG_Abstract_072616
EricKatzen_NEEG_Abstract_072616EricKatzen_NEEG_Abstract_072616
EricKatzen_NEEG_Abstract_072616
Eric Katzen
 

Similar to Concrete Containment Tendon Grease Sampling and Analysis (20)

Analysis of In-Service Oils Following ASTM D5185 with the Avio 200 ICP-OES
Analysis of In-Service Oils Following ASTM D5185 with the Avio 200 ICP-OESAnalysis of In-Service Oils Following ASTM D5185 with the Avio 200 ICP-OES
Analysis of In-Service Oils Following ASTM D5185 with the Avio 200 ICP-OES
 
Analysis of Oil Additives Following ASTM D4951 with the Avio 200 ICP-OES
Analysis of Oil Additives Following ASTM D4951 with the Avio 200 ICP-OESAnalysis of Oil Additives Following ASTM D4951 with the Avio 200 ICP-OES
Analysis of Oil Additives Following ASTM D4951 with the Avio 200 ICP-OES
 
XRF Based &Multi-Metals & Continuous Water Analyzer Xact920
XRF Based &Multi-Metals & Continuous Water Analyzer Xact920XRF Based &Multi-Metals & Continuous Water Analyzer Xact920
XRF Based &Multi-Metals & Continuous Water Analyzer Xact920
 
From Crude to Fuels – Trace Metals Analysis by ICP-OES for ASTM D7691 and D7111
From Crude to Fuels – Trace Metals Analysis by ICP-OES for ASTM D7691 and D7111From Crude to Fuels – Trace Metals Analysis by ICP-OES for ASTM D7691 and D7111
From Crude to Fuels – Trace Metals Analysis by ICP-OES for ASTM D7691 and D7111
 
Analysis of Vanadium, Nickel, Sodium, and Iron in Fuel Oils using Flame Atomi...
Analysis of Vanadium, Nickel, Sodium, and Iron in Fuel Oils using Flame Atomi...Analysis of Vanadium, Nickel, Sodium, and Iron in Fuel Oils using Flame Atomi...
Analysis of Vanadium, Nickel, Sodium, and Iron in Fuel Oils using Flame Atomi...
 
XRF Based Multi-Metals Continuous Water Analyzer
XRF Based Multi-Metals Continuous Water AnalyzerXRF Based Multi-Metals Continuous Water Analyzer
XRF Based Multi-Metals Continuous Water Analyzer
 
Optimized maspi pama april 2009 rev1 pomer point
Optimized maspi pama april 2009 rev1 pomer pointOptimized maspi pama april 2009 rev1 pomer point
Optimized maspi pama april 2009 rev1 pomer point
 
Jop description for Senior lab chemist ( shift leader)
Jop description for Senior lab chemist ( shift leader)Jop description for Senior lab chemist ( shift leader)
Jop description for Senior lab chemist ( shift leader)
 
Haytham CV 2015 final October
Haytham CV 2015 final OctoberHaytham CV 2015 final October
Haytham CV 2015 final October
 
Enhancing Volatile Organic Compounds in Water
Enhancing Volatile Organic Compounds in Water Enhancing Volatile Organic Compounds in Water
Enhancing Volatile Organic Compounds in Water
 
Investigation of Metal and Chemical Hydrides for Hydrogen Storage in Novel Fu...
Investigation of Metal and Chemical Hydrides for Hydrogen Storage in Novel Fu...Investigation of Metal and Chemical Hydrides for Hydrogen Storage in Novel Fu...
Investigation of Metal and Chemical Hydrides for Hydrogen Storage in Novel Fu...
 
Corrosion resistantalloysintheoilandgasindustryselectionguidelinesupdate 10073
Corrosion resistantalloysintheoilandgasindustryselectionguidelinesupdate 10073Corrosion resistantalloysintheoilandgasindustryselectionguidelinesupdate 10073
Corrosion resistantalloysintheoilandgasindustryselectionguidelinesupdate 10073
 
PPT - Electronics Industry Wastewater
PPT - Electronics Industry WastewaterPPT - Electronics Industry Wastewater
PPT - Electronics Industry Wastewater
 
Metals Tensile Testing Standards - ISO 6892-1 ASTM E8/8M - Strain Control
Metals Tensile Testing Standards - ISO 6892-1 ASTM E8/8M - Strain ControlMetals Tensile Testing Standards - ISO 6892-1 ASTM E8/8M - Strain Control
Metals Tensile Testing Standards - ISO 6892-1 ASTM E8/8M - Strain Control
 
EricKatzen_NEEG_Abstract_072616
EricKatzen_NEEG_Abstract_072616EricKatzen_NEEG_Abstract_072616
EricKatzen_NEEG_Abstract_072616
 
Biodiesel Fuel Quality
Biodiesel Fuel QualityBiodiesel Fuel Quality
Biodiesel Fuel Quality
 
ASTM D19 Method Validation Procedures
ASTM D19 Method Validation ProceduresASTM D19 Method Validation Procedures
ASTM D19 Method Validation Procedures
 
Sulfur Analysis by GC-SCD using Shimadzu’s SCD-2030 for ASTM D5504, D5623, an...
Sulfur Analysis by GC-SCD using Shimadzu’s SCD-2030 for ASTM D5504, D5623, an...Sulfur Analysis by GC-SCD using Shimadzu’s SCD-2030 for ASTM D5504, D5623, an...
Sulfur Analysis by GC-SCD using Shimadzu’s SCD-2030 for ASTM D5504, D5623, an...
 
Determination of Carbon Dioxide, Ethane And Nitrogen in Natural Gas by Gas C...
Determination of Carbon Dioxide, Ethane  And Nitrogen in Natural Gas by Gas C...Determination of Carbon Dioxide, Ethane  And Nitrogen in Natural Gas by Gas C...
Determination of Carbon Dioxide, Ethane And Nitrogen in Natural Gas by Gas C...
 
Amorim.pdf
Amorim.pdfAmorim.pdf
Amorim.pdf
 

More from Rich Wurzbach

More from Rich Wurzbach (20)

Basics of Grease Sampling: Grease Thief Goes to KSA
Basics of Grease Sampling: Grease Thief Goes to KSABasics of Grease Sampling: Grease Thief Goes to KSA
Basics of Grease Sampling: Grease Thief Goes to KSA
 
Grease Analysis Blitz for Saudi Arabia; Sampling and Analysis
Grease Analysis Blitz for Saudi Arabia; Sampling and AnalysisGrease Analysis Blitz for Saudi Arabia; Sampling and Analysis
Grease Analysis Blitz for Saudi Arabia; Sampling and Analysis
 
Lubricating Machinery during Supply Chain Chaos
Lubricating Machinery during Supply Chain ChaosLubricating Machinery during Supply Chain Chaos
Lubricating Machinery during Supply Chain Chaos
 
Grease Mixing and Compatibility Studies
Grease Mixing and Compatibility StudiesGrease Mixing and Compatibility Studies
Grease Mixing and Compatibility Studies
 
Variable pathlength colorimetric spectroscopy of greases 0314021
Variable pathlength colorimetric spectroscopy of greases 0314021Variable pathlength colorimetric spectroscopy of greases 0314021
Variable pathlength colorimetric spectroscopy of greases 0314021
 
Wind Turbine Blade Bearing Grease Sampling
Wind Turbine Blade Bearing Grease SamplingWind Turbine Blade Bearing Grease Sampling
Wind Turbine Blade Bearing Grease Sampling
 
Ferrous debris measurement in greases
Ferrous debris measurement in greasesFerrous debris measurement in greases
Ferrous debris measurement in greases
 
Grease sampling and analysis overview
Grease sampling and analysis overviewGrease sampling and analysis overview
Grease sampling and analysis overview
 
Variable pathlength colorimetric spectroscopy of greases; enhancements to d7918
Variable pathlength colorimetric spectroscopy of greases; enhancements to d7918Variable pathlength colorimetric spectroscopy of greases; enhancements to d7918
Variable pathlength colorimetric spectroscopy of greases; enhancements to d7918
 
Proactive Grease Analysis - 2018 Machinery Lubrication Conference
Proactive Grease Analysis - 2018 Machinery Lubrication ConferenceProactive Grease Analysis - 2018 Machinery Lubrication Conference
Proactive Grease Analysis - 2018 Machinery Lubrication Conference
 
Ferrous debris changes for d7918
Ferrous debris changes for d7918Ferrous debris changes for d7918
Ferrous debris changes for d7918
 
Variable pathlength colorimetric spectroscopy of greases
Variable pathlength colorimetric spectroscopy of greasesVariable pathlength colorimetric spectroscopy of greases
Variable pathlength colorimetric spectroscopy of greases
 
Grease Thief Technology Overview 051818
Grease Thief Technology Overview 051818Grease Thief Technology Overview 051818
Grease Thief Technology Overview 051818
 
ReliablePlant 2018- Rich Wurzbach presentation on grease cleanliness
ReliablePlant 2018- Rich Wurzbach presentation on grease cleanlinessReliablePlant 2018- Rich Wurzbach presentation on grease cleanliness
ReliablePlant 2018- Rich Wurzbach presentation on grease cleanliness
 
Grease particle counting 04132018
Grease particle counting 04132018Grease particle counting 04132018
Grease particle counting 04132018
 
Wind turbine grease sampling and analysis
Wind turbine grease sampling and analysisWind turbine grease sampling and analysis
Wind turbine grease sampling and analysis
 
Grease sampling workshop SKF 011518
Grease sampling workshop SKF 011518Grease sampling workshop SKF 011518
Grease sampling workshop SKF 011518
 
Grease particle counting ASTM 2015
Grease particle counting ASTM 2015Grease particle counting ASTM 2015
Grease particle counting ASTM 2015
 
Automatic Particle Counting in Greases: STLE2015 Presentation by Rich Wurzbach
Automatic Particle Counting in Greases: STLE2015 Presentation by Rich WurzbachAutomatic Particle Counting in Greases: STLE2015 Presentation by Rich Wurzbach
Automatic Particle Counting in Greases: STLE2015 Presentation by Rich Wurzbach
 
Grease sampling and analysis of main and blade bearings - STLE 2015 presentation
Grease sampling and analysis of main and blade bearings - STLE 2015 presentationGrease sampling and analysis of main and blade bearings - STLE 2015 presentation
Grease sampling and analysis of main and blade bearings - STLE 2015 presentation
 

Recently uploaded

Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune WaterworldsBiogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Sérgio Sacani
 
THE ROLE OF BIOTECHNOLOGY IN THE ECONOMIC UPLIFT.pptx
THE ROLE OF BIOTECHNOLOGY IN THE ECONOMIC UPLIFT.pptxTHE ROLE OF BIOTECHNOLOGY IN THE ECONOMIC UPLIFT.pptx
THE ROLE OF BIOTECHNOLOGY IN THE ECONOMIC UPLIFT.pptx
ANSARKHAN96
 
development of diagnostic enzyme assay to detect leuser virus
development of diagnostic enzyme assay to detect leuser virusdevelopment of diagnostic enzyme assay to detect leuser virus
development of diagnostic enzyme assay to detect leuser virus
NazaninKarimi6
 
POGONATUM : morphology, anatomy, reproduction etc.
POGONATUM : morphology, anatomy, reproduction etc.POGONATUM : morphology, anatomy, reproduction etc.
POGONATUM : morphology, anatomy, reproduction etc.
Silpa
 

Recently uploaded (20)

Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune WaterworldsBiogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
 
Proteomics: types, protein profiling steps etc.
Proteomics: types, protein profiling steps etc.Proteomics: types, protein profiling steps etc.
Proteomics: types, protein profiling steps etc.
 
TransientOffsetin14CAftertheCarringtonEventRecordedbyPolarTreeRings
TransientOffsetin14CAftertheCarringtonEventRecordedbyPolarTreeRingsTransientOffsetin14CAftertheCarringtonEventRecordedbyPolarTreeRings
TransientOffsetin14CAftertheCarringtonEventRecordedbyPolarTreeRings
 
Molecular markers- RFLP, RAPD, AFLP, SNP etc.
Molecular markers- RFLP, RAPD, AFLP, SNP etc.Molecular markers- RFLP, RAPD, AFLP, SNP etc.
Molecular markers- RFLP, RAPD, AFLP, SNP etc.
 
Zoology 5th semester notes( Sumit_yadav).pdf
Zoology 5th semester notes( Sumit_yadav).pdfZoology 5th semester notes( Sumit_yadav).pdf
Zoology 5th semester notes( Sumit_yadav).pdf
 
THE ROLE OF BIOTECHNOLOGY IN THE ECONOMIC UPLIFT.pptx
THE ROLE OF BIOTECHNOLOGY IN THE ECONOMIC UPLIFT.pptxTHE ROLE OF BIOTECHNOLOGY IN THE ECONOMIC UPLIFT.pptx
THE ROLE OF BIOTECHNOLOGY IN THE ECONOMIC UPLIFT.pptx
 
GBSN - Biochemistry (Unit 2) Basic concept of organic chemistry
GBSN - Biochemistry (Unit 2) Basic concept of organic chemistry GBSN - Biochemistry (Unit 2) Basic concept of organic chemistry
GBSN - Biochemistry (Unit 2) Basic concept of organic chemistry
 
300003-World Science Day For Peace And Development.pptx
300003-World Science Day For Peace And Development.pptx300003-World Science Day For Peace And Development.pptx
300003-World Science Day For Peace And Development.pptx
 
Site Acceptance Test .
Site Acceptance Test                    .Site Acceptance Test                    .
Site Acceptance Test .
 
PSYCHOSOCIAL NEEDS. in nursing II sem pptx
PSYCHOSOCIAL NEEDS. in nursing II sem pptxPSYCHOSOCIAL NEEDS. in nursing II sem pptx
PSYCHOSOCIAL NEEDS. in nursing II sem pptx
 
Call Girls Ahmedabad +917728919243 call me Independent Escort Service
Call Girls Ahmedabad +917728919243 call me Independent Escort ServiceCall Girls Ahmedabad +917728919243 call me Independent Escort Service
Call Girls Ahmedabad +917728919243 call me Independent Escort Service
 
PATNA CALL GIRLS 8617370543 LOW PRICE ESCORT SERVICE
PATNA CALL GIRLS 8617370543 LOW PRICE ESCORT SERVICEPATNA CALL GIRLS 8617370543 LOW PRICE ESCORT SERVICE
PATNA CALL GIRLS 8617370543 LOW PRICE ESCORT SERVICE
 
development of diagnostic enzyme assay to detect leuser virus
development of diagnostic enzyme assay to detect leuser virusdevelopment of diagnostic enzyme assay to detect leuser virus
development of diagnostic enzyme assay to detect leuser virus
 
Cyanide resistant respiration pathway.pptx
Cyanide resistant respiration pathway.pptxCyanide resistant respiration pathway.pptx
Cyanide resistant respiration pathway.pptx
 
FAIRSpectra - Enabling the FAIRification of Spectroscopy and Spectrometry
FAIRSpectra - Enabling the FAIRification of Spectroscopy and SpectrometryFAIRSpectra - Enabling the FAIRification of Spectroscopy and Spectrometry
FAIRSpectra - Enabling the FAIRification of Spectroscopy and Spectrometry
 
CURRENT SCENARIO OF POULTRY PRODUCTION IN INDIA
CURRENT SCENARIO OF POULTRY PRODUCTION IN INDIACURRENT SCENARIO OF POULTRY PRODUCTION IN INDIA
CURRENT SCENARIO OF POULTRY PRODUCTION IN INDIA
 
Factory Acceptance Test( FAT).pptx .
Factory Acceptance Test( FAT).pptx       .Factory Acceptance Test( FAT).pptx       .
Factory Acceptance Test( FAT).pptx .
 
POGONATUM : morphology, anatomy, reproduction etc.
POGONATUM : morphology, anatomy, reproduction etc.POGONATUM : morphology, anatomy, reproduction etc.
POGONATUM : morphology, anatomy, reproduction etc.
 
Genome sequencing,shotgun sequencing.pptx
Genome sequencing,shotgun sequencing.pptxGenome sequencing,shotgun sequencing.pptx
Genome sequencing,shotgun sequencing.pptx
 
GBSN - Microbiology (Unit 3)Defense Mechanism of the body
GBSN - Microbiology (Unit 3)Defense Mechanism of the body GBSN - Microbiology (Unit 3)Defense Mechanism of the body
GBSN - Microbiology (Unit 3)Defense Mechanism of the body
 

Concrete Containment Tendon Grease Sampling and Analysis

  • 1. Advanced methods for sampling and analysis of post-tensioned concrete tendon greases Rich Wurzbach ASNT Level III, Infrared and Thermal Testing Laboratory Lubricant Analyst (LLA-I) MRG Labs, York, Pennsylvania, USA
  • 2. Overview  Background of tendon grease testing  Failures of post-tension tendons  Comparison of as-found conditions, failures, to routine grease testing  Root-Cause failure analysis and corrective actions  Enhanced sampling methods  Expanded grease analysis techniques
  • 3. Background  Some nuclear containment designs include ungrouted post-tension concrete tendons  Tendon sheaths and anchorhead areas are filled with a corrosion protection grease  ASME Section XI, IWL-2525 Table 1 contains guidance for corrosion protection grease testing, requires 125g sample minimum
  • 5. Status of referenced tests  ASTM D992 was withdrawn in 1983  Current version of ASTM D4327 allows for testing of all three ions, but IWL-2525-1 specifies this for nitrates only, requires two other tests to be performed.  APHA tests are for environmental and wastewater; often requires samples being split between labs, or being run by inexperienced personnel, may require refrigeration of prepared sample  Total alkalinity test does not fall within the scope of current ASTM standard.
  • 6. Sampling Challenges  Quantity required for current IWL-2525 test slate requires disassembly of tendon anchors can, disturbing anchor area during sampling  Harvesting of grease may disturb position of buttonheads, hiding broken strand indications  Invasive nature of sampling requires costly logistical support, equipment, time, scaffold, etc.
  • 8. Containment Tendon Grease  Tendon failure at US nuclear power plant prompts RCFA, CAR  IWL, Section IX requires 125g grease  Test slate for 2 grams grease developed; tool for sampling remotely
  • 9. Grease thief and T-handle  Provide method to sample grease near anchor without disassembly  Design consistent with ASTM D7718 Standard Practice for Obtaining In-Service Samples of Lubricating Grease  T-handle and stinger probe allow sampling grease from face of anchor  Results from Small Volume Test (SVT) correlated to disassembly method (large volume sample)  Sampling saved ~US$500,000 in maintenance costs
  • 10. Water – D95 (IWL-2525)  Uses distillation glassware  Per ASTM: “The amount of water as determined by this test method…to the nearest 0.05 or 0.1 volume%”, which is 500-1000ppm.   Per Noria Training: D95 “is fairly cumbersome and requires a comparatively large sample to ensure accuracy, which is why it is rarely used in production-style oil analysis labs today”
  • 11. Water – Karl Fischer (SVT)  Per ASTM: KF allows “direct determination of water in the range of 10 to 25,000” ppm  Can be performed on grease via “oven method” to eliminate interferences and improve accuracy  Only a small volume of grease required (about ¼ gram)
  • 12. Water Testing Comparison Image courtesy Noria Corporation, USA Images courtesy Metrohm USA SVT IWL
  • 13. Total Alkalinity Testing  Uses an “ASTM Modified” procedure.  Per ASTM: “determination of acidic or basic constituents in petroleum products and lubricants soluble or nearly soluble in mixtures of toluene and isopropyl alcohol.”  Per ASTM: “This test method is not suitable for measuring the basic constituents of many basic additive-type lubricating oils. Test Method D4739 can be used for this purpose.” Visconorust contains basic detergents
  • 14. Total Alkalinty Comparison  Method developed using 0.5 grams grease and smaller solvent amount  Grease fully dissolves, acidification process followed  Titration performed with both colorimetric and potentiometric (D4793) methods, correlating results  Titration performed per IWL-2525 and new small volume method, correlating results
  • 15. Ion testing  Two of three methods in IWL-2525 allow for ion-specific electrodes  New method for small volume ion-specific electrode method under development  Can create more repeatable, reliable, and quicker test for ions, Chloride, Nitrate and Sulfide
  • 16. SVT Small Volume Test Slate  Ferromagnetic Iron (ppm) – tested with a Hall-effect sensor  Metals spectroscopy – multiple elements, ppm (iron, calcium, etc)  Moisture, ppm  Total Base Number (alkalinity) – using 0.5g sample  Red oxide count (corrosion particulate by microscope or direct-imaging sensor  Die Extrusion Index – evaluating unexpected softening or hardening of the grease  Microbial content – quantification of ATP by grease thin- film extraction
  • 17. Analysis Techniques Sample is received. fdM+ is run Grease Thief Analyzer is performed and substrate is made Two strips are used to make a dilution to run RDE/ICP. One Strip is used for FT-IR. One Strip is Dissolved in Green RULER solution to run RULER.
  • 18. Ferrographic analysis and Red Oxide quantification
  • 19. Results  Data compiled for 500 tendon locations  Strongest correlation between related parameters (Calcium and TBN, Red Oxides and Ferrous Debris)  Some high Red Oxides were found in higher Total Alkalinity locations  Multiple potential failure modes likely contributor to lack of consistent correlation
  • 24. Analysis of Data  Not a clear single failure mode represented by correlated data  Several tendons identified for further testing: high ATP (microbial), several high Red Oxides, & high Red Oxide/Low TBN  Testing showed majority of tendons in good condition, small percentage candidates for disassembly and inspection  Advanced statistics package used for ranking metrics
  • 25. Analysis of Data  Dispersion analysis: failed tendon exceeded 2σ outside the mean for the failed tendon for three parameters Data analysis by Dr. David Polk, Polk-Lepson Research, USA http://www.polk-lepsonresearchgroup.com/
  • 26. Analysis of Data  Regression analysis performed using Red Oxides as the dependent variable (actual measure of corrosion) and assigning weighting factors for scoring  Failed tendon and one other scored 5, and twelve others scored as 4. Data analysis by Dr. David Polk, Polk-Lepson Research, USA http://www.polk-lepsonresearchgroup.com/
  • 27. Summary  Tendon failure modes require reliable and cost-effective method for sampling and analysis  Using new sampling tools per ASTM D7718 without tendon can removal  Small volume testing methods shown to be equivalent or superior to traditional testing  Additional failure modes detectable with small volume test slate

Editor's Notes

  1. APHA American Public Health Association
  2. The Grease ThiefTM is pictured here. The red arrow shows the location of the purge hole, which allows excessive grease to purge out without creating backpressue in the bearing. It is recognized that many electric motor designs do not regularly purge grease out the drain hole when properly greased. It is not suggested that greasers pump enough grease in to fill this fitting. However, it can be substituted for the existing drain plug in many motors, and standby to catch any grease that might come out, instead of it falling to the floor. Then the captured grease can be analyzed. The red piston provides a visual indication of when the grease has begun to slump, leak or pressure drain into the fitting, indication of overgreasing, grease property changes, overheating of the bearing, etc.
  3. fdM+ ferrous debris analyzer Determines the amount of ferrous debris in a sample Grease Thief Analyzer Measures the consistency of the grease FT-IR Tests for mixing, contamination, and oxidation RULER Tests for amount of useful antioxidant life remaining RDE Spectroscopy metals spectroscopy Rheometer Tests the consistency, pumpability, and likeliness of tunneling