2. Earthsafe Fuel Transfer Pump Controllers
C21-C22 MicroFlow
Basic Pump Motor Control
C231-C232 PowerFlow
Critical Service Pump Control
C231VF-C232VF PowerFlow VF
VFD Pump Control
C260 CentraFlow
3-10 Pump Master Power and Control
Dual Power Input with Auto-Switch
C231PC-C232PC PowerFlow PC
Pump Control with Integrated PLC
C231M2-C232M2 PowerFlow M2
Pump Control for Dual Master Control
C231P2-C232P2 PowerFlow P2
Pump Control with Auto Power XFR
3. C21-C22 MicroFlow
Basic Pump Motor Control
C21 – Single Pump
C22 – Dual Pump Controllers
• Safety Disconnect Switch
• 3 Pole Power Contactor
• Overload Protection
4. C231-C232 PowerFlow
Critical Service Pump Control
C231 – Single Pump
C232 – Dual Pump
• Safety Disconnect Switch
• 3 Pole Contactor
• Overload Protection
• Control Power Transformer
• MAN-OFF-AUTO Select Switch
• Current Sensor
• Outputs Not-Auto State
• Output Current Sensor
• Output Control Power ON
Critical Service Design means Manual Mode Start on internal
control power – independent of external control device.
Dual Pump Model accepts 2 independent power sources, one
for each pump
5. C231M2 - C232M2 PowerFlow
Pump Control for Dual Master Control
C231M2 – Single Pump
C232M2 – Dual Pump
• Safety Disconnect Switch
• 3 Pole Contactor
• Overload Protection
• Control Power Transformer
• MAN-OFF-AUTO Select Switch
• Current Sensor
• Dual Pump Start Inputs
• Dual Outputs Not-Auto State
• Dual Output Current Sensor
• Dual Output Control Power ON
Critical Service Design means Manual Mode Start on internal
control power – independent of external control device.
Dual Inputs and Dual Outputs allow for independent control
and monitoring by each of 2 master control panels
6. C231P2 - C232P2 PowerFlow
Pump Control with Auto Dual Power Transfer
C231P2 – Single Pump
C232P2 – Dual Pump
• Safety Disconnect Switch
• 3 Pole Contactor
• Overload Protection
• Control Power Transformer
• MAN-OFF-AUTO Select Switch
• Current Sensor
• Pump Start Inputs
• Outputs Not-Auto State
• Output Current Sensor
• Output Control Power ON
• Outputs Power A and B Valid
Dual Power Inputs and Dual Control Power transformers.
Auto-Switch for Input Power allows either pump to operate on
any single active power source
Critical Service Design means Manual Mode Start on internal
control power – independent of external control device.
7. C241-C242 VariFlow
VFD Pump Control
C231VF – Single Pump
C232VF – Dual Pump
• Safety Disconnect Switch
• MAN-OFF-AUTO Select Switch
• Pump Start Inputs
• Outputs Not-Auto State
• Output Current Sensor
• Output Control Power ON
Pump Control with Variable Frequency Drive
• Allows Soft Start – Soft Stop to Avoid Fluid Hammer Problems
• Allows Pressure Maintenance Control for Boiler Inputs
• Allows Step-Up Flow State for Multi-Generator Supply
8. C231PC – C232PC PowerFlow
Pump Control with Integrated PLC
C231PC – Single Pump
C232PC – Dual Pump
• Safety Disconnect Switch
• MAN-OFF-AUTO Select Switch
• Current Sensors
• Pump Start Inputs
• Outputs Not-Auto State
• Output Current Sensor
• Output Control Power ON
• Ethernet Network Communications
Pump Control with Integrated PLC
• Minimize Wiring for Control and Monitoring
• Allows Pump Control for Multiple Master Controllers
9. C260 CentraFlow
Master Pump Controller
Dual Power Input with Auto Switch
C261 – CentraFlow 230 – 1 PH
C263 – CentraFlow 460 – 3 PH
• Safety Disconnect Switch
• HOA Switch for Each Pump
• Circuit Breaker for Each Pump
• Dual Control Power Sources
• Pump Start Inputs
• Outputs Not-Auto State
• Output Current Sensor
• Output Control Power ON
• Output Power Source A-B Valid
Master Pump Power and Control
• 3-10 Pump Capacity, Single or Three Phase
• Dual Power Source Input with Auto-Switch