1 OBJECTIVE
To use the oscilloscope and function generator to calculate, ob-
tain, and measure the amplitudes and durations (period) of various voltage
signals.
EQUIPMENT REQUIRED
Instruments
Oscilloscope
Digital multimeter
Supplies
DC supply
Function generator
2 THEORY
Oscilloscope
The oscilloscope is the most important instrument available
to the practicing technician or engineer. It permits the visual display of a
voltage signal that can reveal a range of information regarding the operating
characteristics of a circuit or system that is not available with a standard
multimeter.At first glance the instrument may appear complex and difficult
to master. Be assured, however, that once the function of each section of
the oscilloscope is explained and understood the system is used throughout
a set of experiments, your expertise with this important tool will develop
quite rapidly.
In addition to the display of a signal, it can also be used to measure the
average value, rms value, frequency and period of a sinusoidal or nonsinu-
soidal signal. The screen is divided into centimeter divisions in the vertical
and horizontal directions. The vertical sensitivity is provided (or set) in
1
volts/div., while the horizontal scale is provided (or set) in t time (s/div). If
a particular signal occupies 6 vertical divisions and the vertical sensitivity is
5mV/div., the magnitude of the signal can be determined from the following
equation:
Amplitude of signal voltage = voltage sensitivity (V/div.)×deflection (div.)
(1)
Vs=(5mV/div.)(6 div.)=30mV
If one cycle of the same signal occupies 8 divisions on the horizontal scale
with a horizontal sensitivity of 5µs/div., the period and the frequency of the
signal can be determined using the following equations:
Period of signal voltage = horizontal sensitivity (V/div.)×deflection (div.)
(2)
T=(5µs/div.)(8 div.)=40 µs and
f =
1
T
=
1
40µs
= 25kHz
Function Generator
The function generator is a voltage supply that typically
provides a sinusoidal, square-wave, and triangular voltage waveform for a
range of frequencies and amplitudes. Although the frequency of the func-
tion generator can be set by the dial position and appropriate multiplier,
the oscilloscope can be used to precisely set the output frequency. The
scope can also be used to set the amplitude of the function generator since
most function generators simply have an amplitude control with no level
indicators.
Both the scope and the function generator are built to withstand some
abuse, so do not be afraid to try various combinations of dial settings to fully
develop your abilities with this laboratory experiment. In addition, if you
are working in a group, do not let one person perform all the experimental
work. You must spend the time in the laboratory, so you should learn how
to use the equipment properly and develop the skills that you may need for
a job that requires a firm understanding of how to use the oscilloscope and
functions generator.
3 PROCEDURE
3.1 Part 1. The Oscilloscope
The instructor will provide a brief description of the various sections of the
oscilloscope and function generator. In your own words, describe the func-
tion and use of each of the following controls or sections of the oscilloscope.
2
a. Focus of voltage trace:
It focuses the beam on the screen.
b. Intensity of voltage trace:
Adjust the brightness of the beam on the screen.
c. Vertical and horizontal position controls:
Allows the moving of the trace in either screen direction.
d. Vertical sensitivity:
Selects volt/divisions on y-axis.
e. Horizontal sensitivity:
Unit of time/divisions on x-axis
f. Vertical mode selection:
Selects between CH1, CH2, Dual and Add modes
g. AC-GND-DC switch:
Allows for AC or DC coupling of signal to scope and at GND position,
3
establishes ground reference o screen
h. Beam finder:
Locates the trace if it is off screen.
i. Calibrate switches:
Provide for the adjustment of scope from external reference source.
j. Internal sync:
In this position, a part of the input signal is applied from the vertical
amplifier to the trigger circuit to cause the trigger signal synchronously
with the input signal to drive the sweep circuit.
k. Trigger section:
Determines mode of triggering of the sweep voltage.
l. External trigger input:
In this position, the signal which is connected to EXT TRIG input
becomes the triggering signal.
m. Input resistance and capacitance:
The input impedance of many scopes consists of the parallel combina-
tion of a 1 Meg resistance and a 30 pF capacitor.
4
n. Probe:
Measuring devices which reduces loading of scope on a circuit and ef-
fectively increases input impedance of scope by a factor of 10.
3.2 Part 2. The Function Generator
Setup
a. Turn on the oscilloscope and adjust the necessary controls to establish
a clear, bright, horizontal line across the center of the screen. Do not
be afraid to adjust various controls to see their effects on the display.
b. Connect the function generator to one vertical channel of the oscil-
loscope and set the output of the generator to a 1000 Hz sinusoidal
waveform.
c. Set the vertical sensitivity of the scope to 1 V/div. and adjust the
amplitude control of the function generator to establish a 4 V peak-
to-peak (p-p) sinusoidal waveform on the screen.
Horizontal Sensitivity
d. Determine the period of the 1000 Hz sinusoidal waveform in millisec-
onds using the equation T = 1/f.Show all work for each part of the
experiment. Be neat!
(calculated)T=1/f=1/1000Hz=1ms
e. Set the horizontal sensitivity of the scope to 0.2 ms/div. Using the
results of Part 2(d) predict and calculate the number of horizontal
divisions required to properly display one full cycle of the 1000 Hz
signal.
(calculated)Number of divisions=1ms*(1div/0.2ms)=5 division
5
Use the oscilloscope measure the number of required divisions and
insert below. How does the result compare to the calculated number
of divisions?
(measured)Number of divisions=5 divisions
f. Change the horizontal sensitivity of the oscilloscope to 0.5 ms/div.
without touching any of the controls of the function generator. Using
the results of Part 2(d) how many horizontal divisions will now be
required to display one full cycle of the 1000 Hz signal?
(calculated)Number of divisions=1ms*(1div/0.5ms)=2
divisions
Using the oscilloscope measure the number of required divisions and
insert below. How does the result compare to the calculated number
of divisions?
(measured)Number of divisions=2
g. Change the horizontal sensitivity of the oscilloscope to 1 ms/div. with-
out touching any of the controls of the function generator. Using the
results of Part 2(d), how many horizontal divisions will now be require
to display one full cycle of the 1000 Hz signal?
(calculated)Number of divisions=1ms*(1div/1ms)=1
division
6
Using the oscilloscope measure the number of required divisions and
insert below. How does the result compare to the calculated number
of divisions?
(measured)Number of divisions=1
h. What was the effect on the appearance of the sinusoidal waveform as
the horizontal sensitivity was changed from 0.2 ms/div. to 0.5 ms/div.
and finally to 1 ms/div.
.2ms/div takes 5 boxes to display total wave
.5ms/div takes 2 boxes to display total wave
1ms/div takes 1 box to display total wave
Did the frequency of the signal on the screen change with each hor-
izontal sensitivity? What conclusion can you draw from the results
regarding the effect of the chosen horizontal sensitivity on the signal
output of the function generator?
No, the frequency of the signal does not change. Increasing horizontal
sensitivity - e.g. from .1ms to 20µ- enables more sensitive reading of
the frequency.
i. Given a sinusoidal waveform on the screen review the procedure to
determine its frequency. Develop e sequence of steps to calculate the
frequency of a sinusoidal waveform appearing on the screen of an os-
cilloscope.
(a) Adjust timebase to obtain one cycle of the wave
(b) Count the number of divs. occupied by the wave
(c) Note the timebase setting
(d) Multiply timebase setting by number of divs. occupied by the wave.
This is equal to the period of the wave
(e) Obtain its reciprocal; that’s the frequency
Vertical Sensitivity
j. Do not touch the controls of the function generator but set the sensi-
tivity of the scope to 0.2 ms/div. and set the vertical sensitivity to 2
V/div. Using this latter sensitivity, calculate the peak-to-peak value of
the sinusoidal waveform on the screen by first counting the number of
7
vertical divisions between peak values and multiplying by the vertical
sensitivity.
(calculated)Peak-to-peak value=2div*(2V/div)=4Vp−p
k. Change the vertical sensitivity of the oscilloscope to 0.5 V/div. and
repeat Part2(j).
(calculated)Peak-to-peak value=8*(0.5V/div)=4Vp−p
l. What was the effect on the appearance of the sinusoidal waveform as
the vertical sensitivity was changed from 2 V/div. to 0.5 V/div.?
The signal occupied full screen.
Did the peak-to-peak voltage of the sinusoidal signal change with each
vertical sensitivity? What conclusion can you draw from the results
regarding the effect of changing the vertical sensitivity on the output
signal of the function generator?
The peak amplitude did not change with a change in the setting of the
vertical sensitivity.
m. Can the peak or peak-to-peak output voltage of a function generator
be set without the aid of an auxiliary instrument such as an oscillo-
scope or digital multimeter? Explain.
No, there is no voltmeter built into function generator (Except some
digital ones)
3.3 Part 3. Exercises
a. Make all the necessary adjustments to clearly display a 5000 Hz 6 Vp−p
sinusoidal signal on the oscilloscope. Establish the zero volt line at the
center of the screen.
Record the chosen sensitivities:
Vertical sensitivity=1V/div
Horizontal sensitivity=50µs
8
Figure 1:
Draw the waveform on Figure 1 carefully noting the required num-
ber of horizontal and vertical divisions. Add vertical and horizontal
dimensions to the waveform using the chosen sensitivities listed above.
Calculate the period of the waveform on the screen using the number
of horizontal divisions for a full cycles shown.
T(calculated)=4div*(50µs/div)=200µs
b. Repeat Part 3(a) for a 200 Hz 0.8 Vp−p sinusoidal waveform on Figure 2
Vertical sensitivity=.1V/div
Horizontal sensitivity=1ms/div
T (calculated)=5div*(1ms/div)=5ms
9
Figure 2:
c. Repeat Part 3(a) for a 100 kHz 4 Vp−p square wave on Figure 3. Note
that a square wave is called for.
Vertical sensitivity=1V/div
Horizontal sensitivity=1µs/div
T (calculated)=10div*(1µs/div)=10µs
3.4 Part 4. Effect of DC Levels
a. Reestablish the 1 kHz 4Vp−psinusoidal waveform on the screen. Cal-
culate the effective value of the sinusoidal waveform.
Vrms (calculated)= Vrms=4V*1/2*.707=1.41Volts
b. Disconnect the function generator from the scope and measure the
effective (rms) value of the output of the function generator using the
digital meter.
Vrms (measured)=1.35Volts
10
Figure 3:
c. Determine the magnitude of the percent difference between the calcu-
lated and measured levels using the following equation:
%Difference =
Vcalc − Vmeas
Vcalc
× 100%
%Difference=[(1.41-1.35)/1.41]*100=4.74
d. Reconnect the function generator to the scope with the 1kHz 4 Vp−p
signal and switch the AC-GND-DC coupling switch of the vertical
channel to GND. What is the effect?
No trace on the screen
Why? How can this scope function be used?
Adjust vertical position correctly.
e. Now move the AC-GND-DC coupling switch to the AC position. What
is the effect on the screen display? Why? Signal is restored. AC mode
displays only AC component of the input signal.
f. Finally, move the AC-GND-DC coupling switch to the DC position.
11
What is the effect on the screen display? Why?
No difference. Applied signal has no DC component.
g. Construct the input of vi of Figure 4 by placing a DC source in
series with the output of the function generator. Be sure the ground
of the oscilloscope is connected directly to the ground of the function
generator. Measure and record the actual battery voltage using the
DC mode of the digital multimeter.
(measured) DC level=1.45Volts
Figure 4:
h. Apply the input voltage vi of to one channel of the oscilloscope with
the AC-GND-DC coupling switch in the GND position and set the re-
sulting horizontal line (zero reference level) in the middle of the screen.
Then move the AC-GND-DC coupling switch to the AC position and
make rough sketch of the waveform on Figure 5 clearly showing the
zero reference line and the number of vertical and horizontal divisions.
Using the chosen sensitivities label the magnitudes of the various hor-
izontal an vertical grid lines.
i. Switch the position of the AC-GND-DC coupling switch to the DC
mode and make a rough sketch of the resulting waveform on Figure
6including the detail requested in Part 4(h).
The copy of the waveform above with a vertical shift which is equal to
the DC offset. Did the vertical shift of the sinusoidal waveform equal
12
Figure 5:
Figure 6:
13
the DC voltage of the battery.
Yes.
Is the shape of the sinusoidal waveform changed by moving the AC-
GND-DC coupling switch through the various positions?
Yes, in AC position mean of the waveform is zero.
j. Reverse the polarity of the battery of Figure and repeat Parts 4(h)
and (i). Observe the effect on the waveform in the AC and DC modes
and comment below.
3.5 Problems
1. Given v = 20sin2000t, determine
(a) ω
ω=2000 rad/s
(b) f
f = 2000/(2 ∗ 3.14) = 318Hz
(c) T
T = 1/f = 1/318 = 3.14ms
(d) Peak value
Vpeak = 20V
(e) Peak-to-peak value
Vpeak−peak = 40V
(f) Effective value
Vrms = .707 ∗ 20 = 14.1V
(g) DC level
Vdc = 0V
2. Given v = 8 × 10−3sin2π4000t, determine
(a) ω
ω=2*3.14*4000=25.12rad/s
(b) f
f = 4kHz
(c) T
T = 1/f=1/4kHz=250µs
14
(d) Peak value
Vpeak = 8mV
(e) Peak-to-peak value
Vpeak−peak = 16mV
(f) Effective value
Vrms = .707 ∗ 8m = 5.66mV
(g) DC level
Vdc = 0V
3. Given Vrms = 1.2V and a frequency of 400 Hz, determine the math-
ematical expression for the sinusoidal voltage as a function of time.
V (t)=1.7sin(2.51kt)
15
4 Conclusions
16

More Related Content

What's hot

cathode ray oscilloscope
cathode ray oscilloscopecathode ray oscilloscope
cathode ray oscilloscopeAliya Sahir
 
Kinetics of particles impulse momentum method
Kinetics of particles impulse momentum methodKinetics of particles impulse momentum method
Kinetics of particles impulse momentum methodEkeeda
 
Types of AM Receiver
Types of AM Receiver Types of AM Receiver
Types of AM Receiver Waqar Ahmed
 
Electromagnetic Waves presentation
Electromagnetic Waves presentationElectromagnetic Waves presentation
Electromagnetic Waves presentationInstitute of Physics
 
Millimeter wave circular microstrip Patch antenna for 5 g applications
Millimeter wave circular microstrip Patch antenna for 5 g applicationsMillimeter wave circular microstrip Patch antenna for 5 g applications
Millimeter wave circular microstrip Patch antenna for 5 g applicationsGana U Kumar
 
Static and Dynamic characteristics of Measuring Instrument
Static and Dynamic characteristics of Measuring Instrument Static and Dynamic characteristics of Measuring Instrument
Static and Dynamic characteristics of Measuring Instrument Archana Vijayakumar
 
Microwave engineering
Microwave engineeringMicrowave engineering
Microwave engineeringLimon Prince
 
Rec101 unit iii operational amplifier
Rec101 unit iii operational amplifierRec101 unit iii operational amplifier
Rec101 unit iii operational amplifierDr Naim R Kidwai
 
12. Piezo Electric Transducer.pptx
12. Piezo Electric Transducer.pptx12. Piezo Electric Transducer.pptx
12. Piezo Electric Transducer.pptxSAKTHIVELV40
 
Transducer ppt
Transducer pptTransducer ppt
Transducer pptManishaC6
 
Satellite Communication Notes Unit (1 to 3).pdf
Satellite Communication Notes Unit (1 to 3).pdfSatellite Communication Notes Unit (1 to 3).pdf
Satellite Communication Notes Unit (1 to 3).pdfGopalakrishnaU
 
Hybrid model for Transistor, small signal Analysis
Hybrid model for Transistor, small signal AnalysisHybrid model for Transistor, small signal Analysis
Hybrid model for Transistor, small signal AnalysisAbhishek Choksi
 
Electric transducer
Electric transducerElectric transducer
Electric transducerUday Korat
 
Lecture5 diode circuits (1)
Lecture5 diode circuits (1)Lecture5 diode circuits (1)
Lecture5 diode circuits (1)raaako2255
 
Design and Simulation Microstrip patch Antenna using CST Microwave Studio
Design and Simulation Microstrip patch Antenna  using CST Microwave StudioDesign and Simulation Microstrip patch Antenna  using CST Microwave Studio
Design and Simulation Microstrip patch Antenna using CST Microwave StudioAymen Al-obaidi
 

What's hot (20)

cathode ray oscilloscope
cathode ray oscilloscopecathode ray oscilloscope
cathode ray oscilloscope
 
Kinetics of particles impulse momentum method
Kinetics of particles impulse momentum methodKinetics of particles impulse momentum method
Kinetics of particles impulse momentum method
 
Types of AM Receiver
Types of AM Receiver Types of AM Receiver
Types of AM Receiver
 
Electromagnetic Waves presentation
Electromagnetic Waves presentationElectromagnetic Waves presentation
Electromagnetic Waves presentation
 
Millimeter wave circular microstrip Patch antenna for 5 g applications
Millimeter wave circular microstrip Patch antenna for 5 g applicationsMillimeter wave circular microstrip Patch antenna for 5 g applications
Millimeter wave circular microstrip Patch antenna for 5 g applications
 
blake sample-problems
blake sample-problemsblake sample-problems
blake sample-problems
 
Static and Dynamic characteristics of Measuring Instrument
Static and Dynamic characteristics of Measuring Instrument Static and Dynamic characteristics of Measuring Instrument
Static and Dynamic characteristics of Measuring Instrument
 
Microwave engineering
Microwave engineeringMicrowave engineering
Microwave engineering
 
Torque Sensors Explained
Torque Sensors ExplainedTorque Sensors Explained
Torque Sensors Explained
 
RADAR Basics
RADAR BasicsRADAR Basics
RADAR Basics
 
Rec101 unit iii operational amplifier
Rec101 unit iii operational amplifierRec101 unit iii operational amplifier
Rec101 unit iii operational amplifier
 
Spiral Antenna
Spiral Antenna  Spiral Antenna
Spiral Antenna
 
12. Piezo Electric Transducer.pptx
12. Piezo Electric Transducer.pptx12. Piezo Electric Transducer.pptx
12. Piezo Electric Transducer.pptx
 
Transducer ppt
Transducer pptTransducer ppt
Transducer ppt
 
Cw and fm cw radar
Cw and fm cw radarCw and fm cw radar
Cw and fm cw radar
 
Satellite Communication Notes Unit (1 to 3).pdf
Satellite Communication Notes Unit (1 to 3).pdfSatellite Communication Notes Unit (1 to 3).pdf
Satellite Communication Notes Unit (1 to 3).pdf
 
Hybrid model for Transistor, small signal Analysis
Hybrid model for Transistor, small signal AnalysisHybrid model for Transistor, small signal Analysis
Hybrid model for Transistor, small signal Analysis
 
Electric transducer
Electric transducerElectric transducer
Electric transducer
 
Lecture5 diode circuits (1)
Lecture5 diode circuits (1)Lecture5 diode circuits (1)
Lecture5 diode circuits (1)
 
Design and Simulation Microstrip patch Antenna using CST Microwave Studio
Design and Simulation Microstrip patch Antenna  using CST Microwave StudioDesign and Simulation Microstrip patch Antenna  using CST Microwave Studio
Design and Simulation Microstrip patch Antenna using CST Microwave Studio
 

Similar to Experiment reportexample

Introduction to Oscilloscope and Function generator
Introduction to Oscilloscope and Function generatorIntroduction to Oscilloscope and Function generator
Introduction to Oscilloscope and Function generatorcyberns_
 
Cathode Ray Oscilloscope
Cathode Ray OscilloscopeCathode Ray Oscilloscope
Cathode Ray Oscilloscoperajainayat
 
Emicathoderayoscilloscope 120625075906-phpapp01
Emicathoderayoscilloscope 120625075906-phpapp01Emicathoderayoscilloscope 120625075906-phpapp01
Emicathoderayoscilloscope 120625075906-phpapp01HassanNawazish
 
Cathode ray oscilloscope
Cathode ray oscilloscopeCathode ray oscilloscope
Cathode ray oscilloscopeesmaeel21
 
Analog electronics LAB MANUAL
Analog electronics LAB MANUALAnalog electronics LAB MANUAL
Analog electronics LAB MANUALAJAL A J
 
Study of CRO and measusre the voltage and frequency
Study of CRO and measusre the voltage and frequencyStudy of CRO and measusre the voltage and frequency
Study of CRO and measusre the voltage and frequencydreamygyz
 
Lab 2 Report More Linear Operational Amplifiers
Lab 2 Report More Linear Operational AmplifiersLab 2 Report More Linear Operational Amplifiers
Lab 2 Report More Linear Operational AmplifiersKatrina Little
 
Method Of Measuring Projections Multi Function Using The Quick And Accurate O...
Method Of Measuring Projections Multi Function Using The Quick And Accurate O...Method Of Measuring Projections Multi Function Using The Quick And Accurate O...
Method Of Measuring Projections Multi Function Using The Quick And Accurate O...inventionjournals
 
Method Of Measuring Projections Multi Function Using The Quick And Accurate O...
Method Of Measuring Projections Multi Function Using The Quick And Accurate O...Method Of Measuring Projections Multi Function Using The Quick And Accurate O...
Method Of Measuring Projections Multi Function Using The Quick And Accurate O...inventionjournals
 
Emi cathode ray oscilloscope
Emi cathode ray oscilloscopeEmi cathode ray oscilloscope
Emi cathode ray oscilloscopeyssb91
 
Development of Compact P-Band Vector Reflectometer
Development of Compact P-Band Vector Reflectometer Development of Compact P-Band Vector Reflectometer
Development of Compact P-Band Vector Reflectometer IJECEIAES
 
Emi lab manual_vthsem_ece
Emi lab manual_vthsem_eceEmi lab manual_vthsem_ece
Emi lab manual_vthsem_eceAshish Duvey
 
Florida Institute of Technology © 2020 by J. GeringE
Florida Institute of Technology       © 2020 by J. GeringEFlorida Institute of Technology       © 2020 by J. GeringE
Florida Institute of Technology © 2020 by J. GeringEShainaBoling829
 
Amvdd Data Converter Fundamentals
Amvdd Data Converter FundamentalsAmvdd Data Converter Fundamentals
Amvdd Data Converter FundamentalsNiket Chandrashekar
 
cathode ray oscilloscope &function generator
cathode ray oscilloscope &function generatorcathode ray oscilloscope &function generator
cathode ray oscilloscope &function generatormegha agrawal
 

Similar to Experiment reportexample (20)

Introduction to Oscilloscope and Function generator
Introduction to Oscilloscope and Function generatorIntroduction to Oscilloscope and Function generator
Introduction to Oscilloscope and Function generator
 
Ie practical file
Ie practical fileIe practical file
Ie practical file
 
Cathode Ray Oscilloscope
Cathode Ray OscilloscopeCathode Ray Oscilloscope
Cathode Ray Oscilloscope
 
Emicathoderayoscilloscope 120625075906-phpapp01
Emicathoderayoscilloscope 120625075906-phpapp01Emicathoderayoscilloscope 120625075906-phpapp01
Emicathoderayoscilloscope 120625075906-phpapp01
 
Cathode ray oscilloscope
Cathode ray oscilloscopeCathode ray oscilloscope
Cathode ray oscilloscope
 
Cro(nnm)
Cro(nnm)Cro(nnm)
Cro(nnm)
 
Analog electronics LAB MANUAL
Analog electronics LAB MANUALAnalog electronics LAB MANUAL
Analog electronics LAB MANUAL
 
Study of CRO and measusre the voltage and frequency
Study of CRO and measusre the voltage and frequencyStudy of CRO and measusre the voltage and frequency
Study of CRO and measusre the voltage and frequency
 
Lab 2 Report More Linear Operational Amplifiers
Lab 2 Report More Linear Operational AmplifiersLab 2 Report More Linear Operational Amplifiers
Lab 2 Report More Linear Operational Amplifiers
 
Method Of Measuring Projections Multi Function Using The Quick And Accurate O...
Method Of Measuring Projections Multi Function Using The Quick And Accurate O...Method Of Measuring Projections Multi Function Using The Quick And Accurate O...
Method Of Measuring Projections Multi Function Using The Quick And Accurate O...
 
Method Of Measuring Projections Multi Function Using The Quick And Accurate O...
Method Of Measuring Projections Multi Function Using The Quick And Accurate O...Method Of Measuring Projections Multi Function Using The Quick And Accurate O...
Method Of Measuring Projections Multi Function Using The Quick And Accurate O...
 
Emi cathode ray oscilloscope
Emi cathode ray oscilloscopeEmi cathode ray oscilloscope
Emi cathode ray oscilloscope
 
Oscilloscope tutorial
Oscilloscope tutorialOscilloscope tutorial
Oscilloscope tutorial
 
Development of Compact P-Band Vector Reflectometer
Development of Compact P-Band Vector Reflectometer Development of Compact P-Band Vector Reflectometer
Development of Compact P-Band Vector Reflectometer
 
Emi lab manual_vthsem_ece
Emi lab manual_vthsem_eceEmi lab manual_vthsem_ece
Emi lab manual_vthsem_ece
 
CRO
CROCRO
CRO
 
Florida Institute of Technology © 2020 by J. GeringE
Florida Institute of Technology       © 2020 by J. GeringEFlorida Institute of Technology       © 2020 by J. GeringE
Florida Institute of Technology © 2020 by J. GeringE
 
Amvdd Data Converter Fundamentals
Amvdd Data Converter FundamentalsAmvdd Data Converter Fundamentals
Amvdd Data Converter Fundamentals
 
cathode ray oscilloscope &function generator
cathode ray oscilloscope &function generatorcathode ray oscilloscope &function generator
cathode ray oscilloscope &function generator
 
Unit 3 betl 305
Unit 3 betl 305Unit 3 betl 305
Unit 3 betl 305
 

More from Anurag Farkya

More from Anurag Farkya (8)

Final ppt
Final pptFinal ppt
Final ppt
 
Automotive engineering
Automotive engineeringAutomotive engineering
Automotive engineering
 
Layout of b.tech_project_report
Layout of b.tech_project_reportLayout of b.tech_project_report
Layout of b.tech_project_report
 
Anurag
AnuragAnurag
Anurag
 
Ppt by annu
Ppt by annuPpt by annu
Ppt by annu
 
Timemanagement
TimemanagementTimemanagement
Timemanagement
 
Time management
Time managementTime management
Time management
 
Project eprom progr
Project eprom progrProject eprom progr
Project eprom progr
 

Recently uploaded

UNIT-V-ELECTRIC AND HYBRID VEHICLES.pptx
UNIT-V-ELECTRIC AND HYBRID VEHICLES.pptxUNIT-V-ELECTRIC AND HYBRID VEHICLES.pptx
UNIT-V-ELECTRIC AND HYBRID VEHICLES.pptxDineshKumar4165
 
Call Girl Service Global Village Dubai +971509430017 Independent Call Girls G...
Call Girl Service Global Village Dubai +971509430017 Independent Call Girls G...Call Girl Service Global Village Dubai +971509430017 Independent Call Girls G...
Call Girl Service Global Village Dubai +971509430017 Independent Call Girls G...kexey39068
 
定制(Plymouth文凭证书)普利茅斯大学毕业证毕业证成绩单学历认证原版一比一
定制(Plymouth文凭证书)普利茅斯大学毕业证毕业证成绩单学历认证原版一比一定制(Plymouth文凭证书)普利茅斯大学毕业证毕业证成绩单学历认证原版一比一
定制(Plymouth文凭证书)普利茅斯大学毕业证毕业证成绩单学历认证原版一比一fhhkjh
 
如何办理爱尔兰都柏林大学毕业证(UCD毕业证) 成绩单原版一比一
如何办理爱尔兰都柏林大学毕业证(UCD毕业证) 成绩单原版一比一如何办理爱尔兰都柏林大学毕业证(UCD毕业证) 成绩单原版一比一
如何办理爱尔兰都柏林大学毕业证(UCD毕业证) 成绩单原版一比一mjyguplun
 
call girls in Jama Masjid (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
call girls in Jama Masjid (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️call girls in Jama Masjid (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
call girls in Jama Masjid (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️9953056974 Low Rate Call Girls In Saket, Delhi NCR
 
如何办理(UC毕业证书)堪培拉大学毕业证毕业证成绩单原版一比一
如何办理(UC毕业证书)堪培拉大学毕业证毕业证成绩单原版一比一如何办理(UC毕业证书)堪培拉大学毕业证毕业证成绩单原版一比一
如何办理(UC毕业证书)堪培拉大学毕业证毕业证成绩单原版一比一fjjwgk
 
UNOSAFE ELEVATOR PRIVATE LTD BANGALORE BROUCHER
UNOSAFE ELEVATOR PRIVATE LTD BANGALORE BROUCHERUNOSAFE ELEVATOR PRIVATE LTD BANGALORE BROUCHER
UNOSAFE ELEVATOR PRIVATE LTD BANGALORE BROUCHERunosafeads
 
2024 TOP 10 most fuel-efficient vehicles according to the US agency
2024 TOP 10 most fuel-efficient vehicles according to the US agency2024 TOP 10 most fuel-efficient vehicles according to the US agency
2024 TOP 10 most fuel-efficient vehicles according to the US agencyHyundai Motor Group
 
꧁༒☬ 7042364481 (Call Girl) In Dwarka Delhi Escort Service In Delhi Ncr☬༒꧂
꧁༒☬ 7042364481 (Call Girl) In Dwarka Delhi Escort Service In Delhi Ncr☬༒꧂꧁༒☬ 7042364481 (Call Girl) In Dwarka Delhi Escort Service In Delhi Ncr☬༒꧂
꧁༒☬ 7042364481 (Call Girl) In Dwarka Delhi Escort Service In Delhi Ncr☬༒꧂Hot Call Girls In Sector 58 (Noida)
 
原版1:1复刻俄亥俄州立大学毕业证OSU毕业证留信学历认证
原版1:1复刻俄亥俄州立大学毕业证OSU毕业证留信学历认证原版1:1复刻俄亥俄州立大学毕业证OSU毕业证留信学历认证
原版1:1复刻俄亥俄州立大学毕业证OSU毕业证留信学历认证jdkhjh
 
UNIT-1-VEHICLE STRUCTURE AND ENGINES.ppt
UNIT-1-VEHICLE STRUCTURE AND ENGINES.pptUNIT-1-VEHICLE STRUCTURE AND ENGINES.ppt
UNIT-1-VEHICLE STRUCTURE AND ENGINES.pptDineshKumar4165
 
call girls in G.T.B. Nagar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
call girls in  G.T.B. Nagar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️call girls in  G.T.B. Nagar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
call girls in G.T.B. Nagar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️9953056974 Low Rate Call Girls In Saket, Delhi NCR
 
VDA 6.3 Process Approach in Automotive Industries
VDA 6.3 Process Approach in Automotive IndustriesVDA 6.3 Process Approach in Automotive Industries
VDA 6.3 Process Approach in Automotive IndustriesKannanDN
 
VIP Kolkata Call Girl Kasba 👉 8250192130 Available With Room
VIP Kolkata Call Girl Kasba 👉 8250192130  Available With RoomVIP Kolkata Call Girl Kasba 👉 8250192130  Available With Room
VIP Kolkata Call Girl Kasba 👉 8250192130 Available With Roomdivyansh0kumar0
 
办理(PITT毕业证书)美国匹兹堡大学毕业证成绩单原版一比一
办理(PITT毕业证书)美国匹兹堡大学毕业证成绩单原版一比一办理(PITT毕业证书)美国匹兹堡大学毕业证成绩单原版一比一
办理(PITT毕业证书)美国匹兹堡大学毕业证成绩单原版一比一F La
 
Call Girls Vastrapur 7397865700 Ridhima Hire Me Full Night
Call Girls Vastrapur 7397865700 Ridhima Hire Me Full NightCall Girls Vastrapur 7397865700 Ridhima Hire Me Full Night
Call Girls Vastrapur 7397865700 Ridhima Hire Me Full Nightssuser7cb4ff
 
Digamma / CertiCon Company Presentation
Digamma / CertiCon Company  PresentationDigamma / CertiCon Company  Presentation
Digamma / CertiCon Company PresentationMihajloManjak
 
UNIT-II-ENGINE AUXILIARY SYSTEMS &TURBOCHARGER
UNIT-II-ENGINE AUXILIARY SYSTEMS &TURBOCHARGERUNIT-II-ENGINE AUXILIARY SYSTEMS &TURBOCHARGER
UNIT-II-ENGINE AUXILIARY SYSTEMS &TURBOCHARGERDineshKumar4165
 

Recently uploaded (20)

UNIT-V-ELECTRIC AND HYBRID VEHICLES.pptx
UNIT-V-ELECTRIC AND HYBRID VEHICLES.pptxUNIT-V-ELECTRIC AND HYBRID VEHICLES.pptx
UNIT-V-ELECTRIC AND HYBRID VEHICLES.pptx
 
Call Girls In Kirti Nagar 📱 9999965857 🤩 Delhi 🫦 HOT AND SEXY VVIP 🍎 SERVICE
Call Girls In Kirti Nagar 📱  9999965857  🤩 Delhi 🫦 HOT AND SEXY VVIP 🍎 SERVICECall Girls In Kirti Nagar 📱  9999965857  🤩 Delhi 🫦 HOT AND SEXY VVIP 🍎 SERVICE
Call Girls In Kirti Nagar 📱 9999965857 🤩 Delhi 🫦 HOT AND SEXY VVIP 🍎 SERVICE
 
Call Girl Service Global Village Dubai +971509430017 Independent Call Girls G...
Call Girl Service Global Village Dubai +971509430017 Independent Call Girls G...Call Girl Service Global Village Dubai +971509430017 Independent Call Girls G...
Call Girl Service Global Village Dubai +971509430017 Independent Call Girls G...
 
定制(Plymouth文凭证书)普利茅斯大学毕业证毕业证成绩单学历认证原版一比一
定制(Plymouth文凭证书)普利茅斯大学毕业证毕业证成绩单学历认证原版一比一定制(Plymouth文凭证书)普利茅斯大学毕业证毕业证成绩单学历认证原版一比一
定制(Plymouth文凭证书)普利茅斯大学毕业证毕业证成绩单学历认证原版一比一
 
如何办理爱尔兰都柏林大学毕业证(UCD毕业证) 成绩单原版一比一
如何办理爱尔兰都柏林大学毕业证(UCD毕业证) 成绩单原版一比一如何办理爱尔兰都柏林大学毕业证(UCD毕业证) 成绩单原版一比一
如何办理爱尔兰都柏林大学毕业证(UCD毕业证) 成绩单原版一比一
 
call girls in Jama Masjid (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
call girls in Jama Masjid (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️call girls in Jama Masjid (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
call girls in Jama Masjid (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
 
如何办理(UC毕业证书)堪培拉大学毕业证毕业证成绩单原版一比一
如何办理(UC毕业证书)堪培拉大学毕业证毕业证成绩单原版一比一如何办理(UC毕业证书)堪培拉大学毕业证毕业证成绩单原版一比一
如何办理(UC毕业证书)堪培拉大学毕业证毕业证成绩单原版一比一
 
UNOSAFE ELEVATOR PRIVATE LTD BANGALORE BROUCHER
UNOSAFE ELEVATOR PRIVATE LTD BANGALORE BROUCHERUNOSAFE ELEVATOR PRIVATE LTD BANGALORE BROUCHER
UNOSAFE ELEVATOR PRIVATE LTD BANGALORE BROUCHER
 
2024 TOP 10 most fuel-efficient vehicles according to the US agency
2024 TOP 10 most fuel-efficient vehicles according to the US agency2024 TOP 10 most fuel-efficient vehicles according to the US agency
2024 TOP 10 most fuel-efficient vehicles according to the US agency
 
꧁༒☬ 7042364481 (Call Girl) In Dwarka Delhi Escort Service In Delhi Ncr☬༒꧂
꧁༒☬ 7042364481 (Call Girl) In Dwarka Delhi Escort Service In Delhi Ncr☬༒꧂꧁༒☬ 7042364481 (Call Girl) In Dwarka Delhi Escort Service In Delhi Ncr☬༒꧂
꧁༒☬ 7042364481 (Call Girl) In Dwarka Delhi Escort Service In Delhi Ncr☬༒꧂
 
sauth delhi call girls in Connaught Place🔝 9953056974 🔝 escort Service
sauth delhi call girls in  Connaught Place🔝 9953056974 🔝 escort Servicesauth delhi call girls in  Connaught Place🔝 9953056974 🔝 escort Service
sauth delhi call girls in Connaught Place🔝 9953056974 🔝 escort Service
 
原版1:1复刻俄亥俄州立大学毕业证OSU毕业证留信学历认证
原版1:1复刻俄亥俄州立大学毕业证OSU毕业证留信学历认证原版1:1复刻俄亥俄州立大学毕业证OSU毕业证留信学历认证
原版1:1复刻俄亥俄州立大学毕业证OSU毕业证留信学历认证
 
UNIT-1-VEHICLE STRUCTURE AND ENGINES.ppt
UNIT-1-VEHICLE STRUCTURE AND ENGINES.pptUNIT-1-VEHICLE STRUCTURE AND ENGINES.ppt
UNIT-1-VEHICLE STRUCTURE AND ENGINES.ppt
 
call girls in G.T.B. Nagar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
call girls in  G.T.B. Nagar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️call girls in  G.T.B. Nagar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
call girls in G.T.B. Nagar (DELHI) 🔝 >༒9953330565🔝 genuine Escort Service 🔝✔️✔️
 
VDA 6.3 Process Approach in Automotive Industries
VDA 6.3 Process Approach in Automotive IndustriesVDA 6.3 Process Approach in Automotive Industries
VDA 6.3 Process Approach in Automotive Industries
 
VIP Kolkata Call Girl Kasba 👉 8250192130 Available With Room
VIP Kolkata Call Girl Kasba 👉 8250192130  Available With RoomVIP Kolkata Call Girl Kasba 👉 8250192130  Available With Room
VIP Kolkata Call Girl Kasba 👉 8250192130 Available With Room
 
办理(PITT毕业证书)美国匹兹堡大学毕业证成绩单原版一比一
办理(PITT毕业证书)美国匹兹堡大学毕业证成绩单原版一比一办理(PITT毕业证书)美国匹兹堡大学毕业证成绩单原版一比一
办理(PITT毕业证书)美国匹兹堡大学毕业证成绩单原版一比一
 
Call Girls Vastrapur 7397865700 Ridhima Hire Me Full Night
Call Girls Vastrapur 7397865700 Ridhima Hire Me Full NightCall Girls Vastrapur 7397865700 Ridhima Hire Me Full Night
Call Girls Vastrapur 7397865700 Ridhima Hire Me Full Night
 
Digamma / CertiCon Company Presentation
Digamma / CertiCon Company  PresentationDigamma / CertiCon Company  Presentation
Digamma / CertiCon Company Presentation
 
UNIT-II-ENGINE AUXILIARY SYSTEMS &TURBOCHARGER
UNIT-II-ENGINE AUXILIARY SYSTEMS &TURBOCHARGERUNIT-II-ENGINE AUXILIARY SYSTEMS &TURBOCHARGER
UNIT-II-ENGINE AUXILIARY SYSTEMS &TURBOCHARGER
 

Experiment reportexample

  • 1. Experiment 1 Oscilloscope and Function Generator Operation 1 OBJECTIVE To use the oscilloscope and function generator to calculate, ob- tain, and measure the amplitudes and durations (period) of various voltage signals. EQUIPMENT REQUIRED Instruments Oscilloscope Digital multimeter Supplies DC supply Function generator 2 THEORY Oscilloscope The oscilloscope is the most important instrument available to the practicing technician or engineer. It permits the visual display of a voltage signal that can reveal a range of information regarding the operating characteristics of a circuit or system that is not available with a standard multimeter.At first glance the instrument may appear complex and difficult to master. Be assured, however, that once the function of each section of the oscilloscope is explained and understood the system is used throughout a set of experiments, your expertise with this important tool will develop quite rapidly. In addition to the display of a signal, it can also be used to measure the average value, rms value, frequency and period of a sinusoidal or nonsinu- soidal signal. The screen is divided into centimeter divisions in the vertical and horizontal directions. The vertical sensitivity is provided (or set) in 1
  • 2. volts/div., while the horizontal scale is provided (or set) in t time (s/div). If a particular signal occupies 6 vertical divisions and the vertical sensitivity is 5mV/div., the magnitude of the signal can be determined from the following equation: Amplitude of signal voltage = voltage sensitivity (V/div.)×deflection (div.) (1) Vs=(5mV/div.)(6 div.)=30mV If one cycle of the same signal occupies 8 divisions on the horizontal scale with a horizontal sensitivity of 5µs/div., the period and the frequency of the signal can be determined using the following equations: Period of signal voltage = horizontal sensitivity (V/div.)×deflection (div.) (2) T=(5µs/div.)(8 div.)=40 µs and f = 1 T = 1 40µs = 25kHz Function Generator The function generator is a voltage supply that typically provides a sinusoidal, square-wave, and triangular voltage waveform for a range of frequencies and amplitudes. Although the frequency of the func- tion generator can be set by the dial position and appropriate multiplier, the oscilloscope can be used to precisely set the output frequency. The scope can also be used to set the amplitude of the function generator since most function generators simply have an amplitude control with no level indicators. Both the scope and the function generator are built to withstand some abuse, so do not be afraid to try various combinations of dial settings to fully develop your abilities with this laboratory experiment. In addition, if you are working in a group, do not let one person perform all the experimental work. You must spend the time in the laboratory, so you should learn how to use the equipment properly and develop the skills that you may need for a job that requires a firm understanding of how to use the oscilloscope and functions generator. 3 PROCEDURE 3.1 Part 1. The Oscilloscope The instructor will provide a brief description of the various sections of the oscilloscope and function generator. In your own words, describe the func- tion and use of each of the following controls or sections of the oscilloscope. 2
  • 3. a. Focus of voltage trace: It focuses the beam on the screen. b. Intensity of voltage trace: Adjust the brightness of the beam on the screen. c. Vertical and horizontal position controls: Allows the moving of the trace in either screen direction. d. Vertical sensitivity: Selects volt/divisions on y-axis. e. Horizontal sensitivity: Unit of time/divisions on x-axis f. Vertical mode selection: Selects between CH1, CH2, Dual and Add modes g. AC-GND-DC switch: Allows for AC or DC coupling of signal to scope and at GND position, 3
  • 4. establishes ground reference o screen h. Beam finder: Locates the trace if it is off screen. i. Calibrate switches: Provide for the adjustment of scope from external reference source. j. Internal sync: In this position, a part of the input signal is applied from the vertical amplifier to the trigger circuit to cause the trigger signal synchronously with the input signal to drive the sweep circuit. k. Trigger section: Determines mode of triggering of the sweep voltage. l. External trigger input: In this position, the signal which is connected to EXT TRIG input becomes the triggering signal. m. Input resistance and capacitance: The input impedance of many scopes consists of the parallel combina- tion of a 1 Meg resistance and a 30 pF capacitor. 4
  • 5. n. Probe: Measuring devices which reduces loading of scope on a circuit and ef- fectively increases input impedance of scope by a factor of 10. 3.2 Part 2. The Function Generator Setup a. Turn on the oscilloscope and adjust the necessary controls to establish a clear, bright, horizontal line across the center of the screen. Do not be afraid to adjust various controls to see their effects on the display. b. Connect the function generator to one vertical channel of the oscil- loscope and set the output of the generator to a 1000 Hz sinusoidal waveform. c. Set the vertical sensitivity of the scope to 1 V/div. and adjust the amplitude control of the function generator to establish a 4 V peak- to-peak (p-p) sinusoidal waveform on the screen. Horizontal Sensitivity d. Determine the period of the 1000 Hz sinusoidal waveform in millisec- onds using the equation T = 1/f.Show all work for each part of the experiment. Be neat! (calculated)T=1/f=1/1000Hz=1ms e. Set the horizontal sensitivity of the scope to 0.2 ms/div. Using the results of Part 2(d) predict and calculate the number of horizontal divisions required to properly display one full cycle of the 1000 Hz signal. (calculated)Number of divisions=1ms*(1div/0.2ms)=5 division 5
  • 6. Use the oscilloscope measure the number of required divisions and insert below. How does the result compare to the calculated number of divisions? (measured)Number of divisions=5 divisions f. Change the horizontal sensitivity of the oscilloscope to 0.5 ms/div. without touching any of the controls of the function generator. Using the results of Part 2(d) how many horizontal divisions will now be required to display one full cycle of the 1000 Hz signal? (calculated)Number of divisions=1ms*(1div/0.5ms)=2 divisions Using the oscilloscope measure the number of required divisions and insert below. How does the result compare to the calculated number of divisions? (measured)Number of divisions=2 g. Change the horizontal sensitivity of the oscilloscope to 1 ms/div. with- out touching any of the controls of the function generator. Using the results of Part 2(d), how many horizontal divisions will now be require to display one full cycle of the 1000 Hz signal? (calculated)Number of divisions=1ms*(1div/1ms)=1 division 6
  • 7. Using the oscilloscope measure the number of required divisions and insert below. How does the result compare to the calculated number of divisions? (measured)Number of divisions=1 h. What was the effect on the appearance of the sinusoidal waveform as the horizontal sensitivity was changed from 0.2 ms/div. to 0.5 ms/div. and finally to 1 ms/div. .2ms/div takes 5 boxes to display total wave .5ms/div takes 2 boxes to display total wave 1ms/div takes 1 box to display total wave Did the frequency of the signal on the screen change with each hor- izontal sensitivity? What conclusion can you draw from the results regarding the effect of the chosen horizontal sensitivity on the signal output of the function generator? No, the frequency of the signal does not change. Increasing horizontal sensitivity - e.g. from .1ms to 20µ- enables more sensitive reading of the frequency. i. Given a sinusoidal waveform on the screen review the procedure to determine its frequency. Develop e sequence of steps to calculate the frequency of a sinusoidal waveform appearing on the screen of an os- cilloscope. (a) Adjust timebase to obtain one cycle of the wave (b) Count the number of divs. occupied by the wave (c) Note the timebase setting (d) Multiply timebase setting by number of divs. occupied by the wave. This is equal to the period of the wave (e) Obtain its reciprocal; that’s the frequency Vertical Sensitivity j. Do not touch the controls of the function generator but set the sensi- tivity of the scope to 0.2 ms/div. and set the vertical sensitivity to 2 V/div. Using this latter sensitivity, calculate the peak-to-peak value of the sinusoidal waveform on the screen by first counting the number of 7
  • 8. vertical divisions between peak values and multiplying by the vertical sensitivity. (calculated)Peak-to-peak value=2div*(2V/div)=4Vp−p k. Change the vertical sensitivity of the oscilloscope to 0.5 V/div. and repeat Part2(j). (calculated)Peak-to-peak value=8*(0.5V/div)=4Vp−p l. What was the effect on the appearance of the sinusoidal waveform as the vertical sensitivity was changed from 2 V/div. to 0.5 V/div.? The signal occupied full screen. Did the peak-to-peak voltage of the sinusoidal signal change with each vertical sensitivity? What conclusion can you draw from the results regarding the effect of changing the vertical sensitivity on the output signal of the function generator? The peak amplitude did not change with a change in the setting of the vertical sensitivity. m. Can the peak or peak-to-peak output voltage of a function generator be set without the aid of an auxiliary instrument such as an oscillo- scope or digital multimeter? Explain. No, there is no voltmeter built into function generator (Except some digital ones) 3.3 Part 3. Exercises a. Make all the necessary adjustments to clearly display a 5000 Hz 6 Vp−p sinusoidal signal on the oscilloscope. Establish the zero volt line at the center of the screen. Record the chosen sensitivities: Vertical sensitivity=1V/div Horizontal sensitivity=50µs 8
  • 9. Figure 1: Draw the waveform on Figure 1 carefully noting the required num- ber of horizontal and vertical divisions. Add vertical and horizontal dimensions to the waveform using the chosen sensitivities listed above. Calculate the period of the waveform on the screen using the number of horizontal divisions for a full cycles shown. T(calculated)=4div*(50µs/div)=200µs b. Repeat Part 3(a) for a 200 Hz 0.8 Vp−p sinusoidal waveform on Figure 2 Vertical sensitivity=.1V/div Horizontal sensitivity=1ms/div T (calculated)=5div*(1ms/div)=5ms 9
  • 10. Figure 2: c. Repeat Part 3(a) for a 100 kHz 4 Vp−p square wave on Figure 3. Note that a square wave is called for. Vertical sensitivity=1V/div Horizontal sensitivity=1µs/div T (calculated)=10div*(1µs/div)=10µs 3.4 Part 4. Effect of DC Levels a. Reestablish the 1 kHz 4Vp−psinusoidal waveform on the screen. Cal- culate the effective value of the sinusoidal waveform. Vrms (calculated)= Vrms=4V*1/2*.707=1.41Volts b. Disconnect the function generator from the scope and measure the effective (rms) value of the output of the function generator using the digital meter. Vrms (measured)=1.35Volts 10
  • 11. Figure 3: c. Determine the magnitude of the percent difference between the calcu- lated and measured levels using the following equation: %Difference = Vcalc − Vmeas Vcalc × 100% %Difference=[(1.41-1.35)/1.41]*100=4.74 d. Reconnect the function generator to the scope with the 1kHz 4 Vp−p signal and switch the AC-GND-DC coupling switch of the vertical channel to GND. What is the effect? No trace on the screen Why? How can this scope function be used? Adjust vertical position correctly. e. Now move the AC-GND-DC coupling switch to the AC position. What is the effect on the screen display? Why? Signal is restored. AC mode displays only AC component of the input signal. f. Finally, move the AC-GND-DC coupling switch to the DC position. 11
  • 12. What is the effect on the screen display? Why? No difference. Applied signal has no DC component. g. Construct the input of vi of Figure 4 by placing a DC source in series with the output of the function generator. Be sure the ground of the oscilloscope is connected directly to the ground of the function generator. Measure and record the actual battery voltage using the DC mode of the digital multimeter. (measured) DC level=1.45Volts Figure 4: h. Apply the input voltage vi of to one channel of the oscilloscope with the AC-GND-DC coupling switch in the GND position and set the re- sulting horizontal line (zero reference level) in the middle of the screen. Then move the AC-GND-DC coupling switch to the AC position and make rough sketch of the waveform on Figure 5 clearly showing the zero reference line and the number of vertical and horizontal divisions. Using the chosen sensitivities label the magnitudes of the various hor- izontal an vertical grid lines. i. Switch the position of the AC-GND-DC coupling switch to the DC mode and make a rough sketch of the resulting waveform on Figure 6including the detail requested in Part 4(h). The copy of the waveform above with a vertical shift which is equal to the DC offset. Did the vertical shift of the sinusoidal waveform equal 12
  • 14. the DC voltage of the battery. Yes. Is the shape of the sinusoidal waveform changed by moving the AC- GND-DC coupling switch through the various positions? Yes, in AC position mean of the waveform is zero. j. Reverse the polarity of the battery of Figure and repeat Parts 4(h) and (i). Observe the effect on the waveform in the AC and DC modes and comment below. 3.5 Problems 1. Given v = 20sin2000t, determine (a) ω ω=2000 rad/s (b) f f = 2000/(2 ∗ 3.14) = 318Hz (c) T T = 1/f = 1/318 = 3.14ms (d) Peak value Vpeak = 20V (e) Peak-to-peak value Vpeak−peak = 40V (f) Effective value Vrms = .707 ∗ 20 = 14.1V (g) DC level Vdc = 0V 2. Given v = 8 × 10−3sin2π4000t, determine (a) ω ω=2*3.14*4000=25.12rad/s (b) f f = 4kHz (c) T T = 1/f=1/4kHz=250µs 14
  • 15. (d) Peak value Vpeak = 8mV (e) Peak-to-peak value Vpeak−peak = 16mV (f) Effective value Vrms = .707 ∗ 8m = 5.66mV (g) DC level Vdc = 0V 3. Given Vrms = 1.2V and a frequency of 400 Hz, determine the math- ematical expression for the sinusoidal voltage as a function of time. V (t)=1.7sin(2.51kt) 15