ANALYSIS OF
CONDENSER
OPERATION
PRESENTED BY : SUMIT WADEWALE
: MECHANICAL ENGINEERING
: ROLL NO : 629
SUB: APPLIED THERMODYNAMICS -I
BAJAJ INSTITUTE OF TECHNOLOGY, WARDHA
VACUUM CREATION
 When steam condenses in a closed vessel, the
vapour phase of working substance (water)
changes to liquid phase, and thus its specific
volume reduces to more than one thousand
times. Due to change in specific volume, the
absolute pressure in the condenser falls below
the atmospheric pressure and high vacuum is
created.
This lower pressure in the condenser permits maximum
expansion of steam in the turbine, and more work is
developed. The minimum pressure that can be attained
depends on the temperature of condensate and air present
in the condenser.
The term vacuum means the pressures below the
atmospheric pressure. The vacuum in the condenser is
generally measured in mm of mercury (Hg). The vacuum is
the negative gauge pressure and is equal to the differences
of barometric pressure and absolute pressure in the
condenser.
The absolute pressure in the condenser
= atmospheric pressure – vacuum gauge pressure
= barometer reading – vacuum gauge reading
The vacuum is usually referred to a standard atmospheric
pressure as 101.325 kPa or 760 mm of Hg, i.e.
At any barometric reading other than standard reading of
760 mm of Hg, the vacuum gauge reading is corrected to
standard barometric reading as
corrected in mm of Hg =
Standard barometer reading –
(Actual barometer reading – vacuum gauge reading )
The absolute pressure in condenser can be determined as
Pabs = 760 mm – corrected vacuum in mm of
Hg
DALTONS LAW OF PARTIAL
PRESSURE
For a mixture of non reactive gases, the total
(mixture) is given by
Where Pi is the pressure of ith gas component at the mixture
temperature T and volume V.
According to Dalton’s law, the total pressure of a non-
reactive mixture is equal to sum of partial of its components, if
each component would occupy the same volume alone at the
mixture temperature.
the condenser has a mixture of wet steam and air. The
total pressure p in the condenser is the sum of partial pressure
of steam, Psat and air Pa.
The saturation pressure of steam Psat can be obtained from the
steam table at condensate (saturation) temperature.
According to Dalton’s law,
P = psat + pa
or pa = p - psat
With the help of partial pressure of air, the mass of air can be
determined as,
Where, V is the volume of condenser, Tsat is the
condensate temp and Ra is characteristic gas constant of
air which is equal to 287 J/KgK
In the steam condenser, a mixture of steam and air is
present. Therefore, the absolute pressure in the
condenser is the sum of partial pressures of steam and air.
The presence of air in the condenser disturbs the vacuum
is less than that could be attained in the condenser, if only
steam is present. If no airt is present in the condenser
then absolute pressure bin the condenser is the
saturation pressure of steam and thus the maximum
vacuum would be attained.
Where pg is the actual vacuum
= barometric pressure – absolute pressure in
condenser
= patm – p
Maximum possible vacuum
Pg, max = barometric pressure – sat. pressure of steam corresponding to
condensate temperature
= patm - psat
The vacuum efficiency is defined as the ratio of
actual vacuum to the maximum possible vacuum.
SOURCES OF AIR IN THE
CONDENSER
All types of condensers require air extraction pump to remove the air present in the
condenser. The main sources of air present in the condenser are the following:
 the ambient air leaks to the condenser chamber at the joints and glands
which are internally under pressure lower than that of ambient. It can be
reduced by taking utmost care while designing and making vacuum joints.
 another source of air is dissolved air with feed water. The dissolved air in
the feed water enters into the boiler and it travels with steam into the
condenser. Its quantity depends upon the quality of feed water.
 In case of jet condenser, some air comes in with the injected water in which
it is dissolved.
EFFECT OF AIR LEAKAGE INTO
CONDENSER
The presence of air in the condenser is a far serious concern. It affects
the performance of the condenser to a great extent, thereby, the
performance of steam power plant. The presence of air into the
condenser puts the following effects:
 the presence of air lowers the vacuum in the condenser.
Thus the back pressure of plant increases, and consequently,
the work output of the turbine reduces.
the presence of air also lowers the partial pressure of steam
and hence lower saturation temperature. The steam with lower
saturation temperature has higher latent heat. A large quantity
of cooling water is required to get the desired result in the
condenser.
 Air forms the film adjacent to the tube surface in the
condenser. Air has very poor thermal conductivity. Hence, the
rate of heat transfer from vapour to cooling medium is reduced.
The presence of air in the condenser corrodes to the metal
surfaces. Therefore, the life of condenser is reduced.
THANK YOU

More Related Content

What's hot

Condenser in Thermal Power Plant
Condenser in Thermal Power PlantCondenser in Thermal Power Plant
Condenser in Thermal Power PlantMihir Patel
 
Calculation of Turbine Efficiency
Calculation of Turbine EfficiencyCalculation of Turbine Efficiency
Calculation of Turbine EfficiencyJahanzeb Khan
 
Steam condenser
Steam condenserSteam condenser
Steam condenserAkshayV27
 
DESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZERDESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZERGopi Chand
 
Presentation cooling tower
Presentation cooling towerPresentation cooling tower
Presentation cooling towerALOK KUMAR SWAIN
 
Guide to Furnace Sootblowing
Guide to Furnace SootblowingGuide to Furnace Sootblowing
Guide to Furnace SootblowingRichard Smith
 
Cryogenic air separation plant design
Cryogenic air separation plant designCryogenic air separation plant design
Cryogenic air separation plant designRahul Ghalme
 
Heat rate audit in thermal power plant
Heat rate audit in thermal power plantHeat rate audit in thermal power plant
Heat rate audit in thermal power plantSHIVAJI CHOUDHURY
 
Cooling water system presentation
Cooling water system presentationCooling water system presentation
Cooling water system presentationumar farooq
 
Performance calculation for feed water heater
Performance calculation  for feed water heaterPerformance calculation  for feed water heater
Performance calculation for feed water heaterSHIVAJI CHOUDHURY
 
Boiler accessories
Boiler accessoriesBoiler accessories
Boiler accessoriesrudrik joshi
 
Boiler Efficiency Calculations
Boiler Efficiency CalculationsBoiler Efficiency Calculations
Boiler Efficiency CalculationsManohar Tatwawadi
 
Cooling water system
Cooling water systemCooling water system
Cooling water systemumar farooq
 

What's hot (20)

Condenser in Thermal Power Plant
Condenser in Thermal Power PlantCondenser in Thermal Power Plant
Condenser in Thermal Power Plant
 
Calculation of Turbine Efficiency
Calculation of Turbine EfficiencyCalculation of Turbine Efficiency
Calculation of Turbine Efficiency
 
Boiler calculations
Boiler calculationsBoiler calculations
Boiler calculations
 
Steam condenser
Steam condenserSteam condenser
Steam condenser
 
Steam condensors
Steam condensorsSteam condensors
Steam condensors
 
cooling towers
 cooling towers cooling towers
cooling towers
 
DESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZERDESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZER
 
Presentation cooling tower
Presentation cooling towerPresentation cooling tower
Presentation cooling tower
 
Guide to Furnace Sootblowing
Guide to Furnace SootblowingGuide to Furnace Sootblowing
Guide to Furnace Sootblowing
 
Cryogenic air separation plant design
Cryogenic air separation plant designCryogenic air separation plant design
Cryogenic air separation plant design
 
Steam Pressure Reducing Station
Steam Pressure Reducing StationSteam Pressure Reducing Station
Steam Pressure Reducing Station
 
Analysis of Steam Cycles
Analysis of Steam CyclesAnalysis of Steam Cycles
Analysis of Steam Cycles
 
Heat rate audit in thermal power plant
Heat rate audit in thermal power plantHeat rate audit in thermal power plant
Heat rate audit in thermal power plant
 
Cooling water system presentation
Cooling water system presentationCooling water system presentation
Cooling water system presentation
 
Performance calculation for feed water heater
Performance calculation  for feed water heaterPerformance calculation  for feed water heater
Performance calculation for feed water heater
 
Boiler accessories
Boiler accessoriesBoiler accessories
Boiler accessories
 
Heat exchangers
Heat exchangersHeat exchangers
Heat exchangers
 
Boiler Efficiency Calculations
Boiler Efficiency CalculationsBoiler Efficiency Calculations
Boiler Efficiency Calculations
 
Boilers
BoilersBoilers
Boilers
 
Cooling water system
Cooling water systemCooling water system
Cooling water system
 

Similar to ANALYSIS OF CONDENSER OPERATION (20)

THERMODYNAMICS - UNIT - V
 THERMODYNAMICS - UNIT - V THERMODYNAMICS - UNIT - V
THERMODYNAMICS - UNIT - V
 
Condensers
CondensersCondensers
Condensers
 
Condenser and its types
Condenser and its types Condenser and its types
Condenser and its types
 
Rac, module 5 note
Rac, module 5 noteRac, module 5 note
Rac, module 5 note
 
Steam condenser copy
Steam condenser    copySteam condenser    copy
Steam condenser copy
 
Cryogenic air separation brochure19 4353 tcm136-414865
Cryogenic air separation brochure19 4353 tcm136-414865Cryogenic air separation brochure19 4353 tcm136-414865
Cryogenic air separation brochure19 4353 tcm136-414865
 
vapour pressure
vapour pressurevapour pressure
vapour pressure
 
Gas laws in anaesthesia
Gas laws in anaesthesiaGas laws in anaesthesia
Gas laws in anaesthesia
 
Modified gas laws
Modified gas lawsModified gas laws
Modified gas laws
 
Turbine aux
Turbine auxTurbine aux
Turbine aux
 
Steam condensers
Steam condensersSteam condensers
Steam condensers
 
Physics and its laws in anaesthesia
Physics and its laws in anaesthesiaPhysics and its laws in anaesthesia
Physics and its laws in anaesthesia
 
Physics and its laws in anesthesia
Physics and its laws in anesthesiaPhysics and its laws in anesthesia
Physics and its laws in anesthesia
 
HYDRAULICS AND PNEUMATICS (UNIT 4)
HYDRAULICS AND PNEUMATICS   (UNIT 4)HYDRAULICS AND PNEUMATICS   (UNIT 4)
HYDRAULICS AND PNEUMATICS (UNIT 4)
 
Humidity
HumidityHumidity
Humidity
 
Combustion chamber of Gas turbine power plant cycle
Combustion chamber of Gas turbine power plant cycleCombustion chamber of Gas turbine power plant cycle
Combustion chamber of Gas turbine power plant cycle
 
Steam condenser & cooling tower .pptx
Steam condenser &  cooling tower   .pptxSteam condenser &  cooling tower   .pptx
Steam condenser & cooling tower .pptx
 
Bq34416421
Bq34416421Bq34416421
Bq34416421
 
WIND AND AIR.docx
WIND AND AIR.docxWIND AND AIR.docx
WIND AND AIR.docx
 
Rotary Compressors.pptx
Rotary Compressors.pptxRotary Compressors.pptx
Rotary Compressors.pptx
 

Recently uploaded

(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINESIVASHANKAR N
 
main PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfidmain PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfidNikhilNagaraju
 
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSSIVASHANKAR N
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Dr.Costas Sachpazis
 
Analog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog ConverterAnalog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog ConverterAbhinavSharma374939
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile servicerehmti665
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
chaitra-1.pptx fake news detection using machine learning
chaitra-1.pptx  fake news detection using machine learningchaitra-1.pptx  fake news detection using machine learning
chaitra-1.pptx fake news detection using machine learningmisbanausheenparvam
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxwendy cai
 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escortsranjana rawat
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )Tsuyoshi Horigome
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxpranjaldaimarysona
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxupamatechverse
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130Suhani Kapoor
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxupamatechverse
 

Recently uploaded (20)

(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
 
main PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfidmain PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfid
 
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
 
Analog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog ConverterAnalog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog Converter
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile service
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
chaitra-1.pptx fake news detection using machine learning
chaitra-1.pptx  fake news detection using machine learningchaitra-1.pptx  fake news detection using machine learning
chaitra-1.pptx fake news detection using machine learning
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptx
 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
 
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINEDJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
 
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptx
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptx
 
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptx
 

ANALYSIS OF CONDENSER OPERATION

  • 1. ANALYSIS OF CONDENSER OPERATION PRESENTED BY : SUMIT WADEWALE : MECHANICAL ENGINEERING : ROLL NO : 629 SUB: APPLIED THERMODYNAMICS -I BAJAJ INSTITUTE OF TECHNOLOGY, WARDHA
  • 2. VACUUM CREATION  When steam condenses in a closed vessel, the vapour phase of working substance (water) changes to liquid phase, and thus its specific volume reduces to more than one thousand times. Due to change in specific volume, the absolute pressure in the condenser falls below the atmospheric pressure and high vacuum is created.
  • 3. This lower pressure in the condenser permits maximum expansion of steam in the turbine, and more work is developed. The minimum pressure that can be attained depends on the temperature of condensate and air present in the condenser. The term vacuum means the pressures below the atmospheric pressure. The vacuum in the condenser is generally measured in mm of mercury (Hg). The vacuum is the negative gauge pressure and is equal to the differences of barometric pressure and absolute pressure in the condenser.
  • 4.
  • 5. The absolute pressure in the condenser = atmospheric pressure – vacuum gauge pressure = barometer reading – vacuum gauge reading The vacuum is usually referred to a standard atmospheric pressure as 101.325 kPa or 760 mm of Hg, i.e.
  • 6. At any barometric reading other than standard reading of 760 mm of Hg, the vacuum gauge reading is corrected to standard barometric reading as corrected in mm of Hg = Standard barometer reading – (Actual barometer reading – vacuum gauge reading ) The absolute pressure in condenser can be determined as Pabs = 760 mm – corrected vacuum in mm of Hg
  • 7. DALTONS LAW OF PARTIAL PRESSURE For a mixture of non reactive gases, the total (mixture) is given by Where Pi is the pressure of ith gas component at the mixture temperature T and volume V.
  • 8. According to Dalton’s law, the total pressure of a non- reactive mixture is equal to sum of partial of its components, if each component would occupy the same volume alone at the mixture temperature. the condenser has a mixture of wet steam and air. The total pressure p in the condenser is the sum of partial pressure of steam, Psat and air Pa. The saturation pressure of steam Psat can be obtained from the steam table at condensate (saturation) temperature. According to Dalton’s law, P = psat + pa or pa = p - psat
  • 9. With the help of partial pressure of air, the mass of air can be determined as, Where, V is the volume of condenser, Tsat is the condensate temp and Ra is characteristic gas constant of air which is equal to 287 J/KgK
  • 10. In the steam condenser, a mixture of steam and air is present. Therefore, the absolute pressure in the condenser is the sum of partial pressures of steam and air. The presence of air in the condenser disturbs the vacuum is less than that could be attained in the condenser, if only steam is present. If no airt is present in the condenser then absolute pressure bin the condenser is the saturation pressure of steam and thus the maximum vacuum would be attained.
  • 11. Where pg is the actual vacuum = barometric pressure – absolute pressure in condenser = patm – p Maximum possible vacuum Pg, max = barometric pressure – sat. pressure of steam corresponding to condensate temperature = patm - psat The vacuum efficiency is defined as the ratio of actual vacuum to the maximum possible vacuum.
  • 12. SOURCES OF AIR IN THE CONDENSER All types of condensers require air extraction pump to remove the air present in the condenser. The main sources of air present in the condenser are the following:  the ambient air leaks to the condenser chamber at the joints and glands which are internally under pressure lower than that of ambient. It can be reduced by taking utmost care while designing and making vacuum joints.  another source of air is dissolved air with feed water. The dissolved air in the feed water enters into the boiler and it travels with steam into the condenser. Its quantity depends upon the quality of feed water.  In case of jet condenser, some air comes in with the injected water in which it is dissolved.
  • 13. EFFECT OF AIR LEAKAGE INTO CONDENSER The presence of air in the condenser is a far serious concern. It affects the performance of the condenser to a great extent, thereby, the performance of steam power plant. The presence of air into the condenser puts the following effects:  the presence of air lowers the vacuum in the condenser. Thus the back pressure of plant increases, and consequently, the work output of the turbine reduces.
  • 14. the presence of air also lowers the partial pressure of steam and hence lower saturation temperature. The steam with lower saturation temperature has higher latent heat. A large quantity of cooling water is required to get the desired result in the condenser.  Air forms the film adjacent to the tube surface in the condenser. Air has very poor thermal conductivity. Hence, the rate of heat transfer from vapour to cooling medium is reduced. The presence of air in the condenser corrodes to the metal surfaces. Therefore, the life of condenser is reduced.