1. Sustainable Well Pad Based
Production Water
Distillation & Evaporation Remediation
2. (c) ESWS 2015
All oil & gas wells make
produced water for life of well
◦ Contains salt, metals & dirt
◦ Very expensive to treat and
transport
◦ Every Oil & Gas Well has Produced
Water that needs to be transported
to treatment or disposal
3. 3
On-site autonomous, sustainable, proprietary
solar/natural gas hybrid solution:
Basin/produced water characteristics agnostic
◦ Effluents:
◦ Distilled water - Evaporated on Well-Pad (permit
exempt)
◦ Residual non-hazardous solids - Land filled or deep
well injected
Eliminates truck traffic, transport risk and
carbon footprint
Can reduce operator produced water
remediation costs by 20-50%
Epiphany Overview Video
(c) ESWS 2015
4. Rapid Deployment
◦ Deployment in 2-3 Days
◦ Standard 20’ Shipping Container
Very Low Operating Costs
◦ Continuous Autonomous Operation
◦ No Manual Intervention Required
No Consumables
◦ Only Input Water Filter Cleaning
◦ System Includes Auto-backflush
Hybrid Power
◦ Concentrated Solar for Heat Energy
◦ Natural Gas or Propane
Generator Power
Optional Heat Energy
(c) ESWS 2015
5. Autonomous Central Operation
◦ Multiple Units From a Single Control Center
◦ Dashboard and Data From Each Unit
Remote Monitoring and Management
◦ Auto-notification of Out of Range Conditions
◦ Sent via Internet to E-mail or Cell Phone
◦ Notification of Any System Issues
Internet Connectivity
◦ 3G or Satellite Communications
◦ Small Data Packets, Low Data Costs
◦ Connect Local Units via Wireless Repeater
Intranet
5
(c) ESWS 2015
6. 1. Unit installed directly on well pad
2. Produced water pumped from well pad tanks
3. Heat Transfer Fluid (HTF) heated by either Concentrated Solar
Power (CSP) or natural gas powered heater if sun is not shining
4. HTF and Produced Water pumped through heat exchangers,
transferring HTF heat to source water
5. Produced Water is flash vaporized in distillation unit creating
steam, re-condensed to purified water
6. Clean water (<250ppm) sent to Epiphany Evaporator on well pad
7. Slurry augured directly into a roll-off container
◦ Or concentrated brine pumped to tanks for Operator
6
(c) ESWS 2015
7. (c) ESWS 2015
System Specifications
Capacity 1 BBl (42+ gallons) per hour
Water Input Piping 13mm (1/2”) Water Feed
Input Water Any Water up to 250,000 PPM TDS
Output Water Less than 250 PPM TDS
Ship/Install Size L 20’, W 8’, H 8’6””
Dry Weight 3200 Kg (7000 lbs.)
9. (c) ESWS 2015
System Specifications
Evaporation Rate 3.0 bbl/hr* (126 GPH)
Evaporation Efficiency 90-100%
Input Water Quality DI, rain, <500 ppm TDS
Power Requirements 3.8kW Electric (230V – 1ph-17A)
Operational Expense L 1.2m, W 1.2m, H 2.4m (L 4’, W4; H8’)
Dry Weight 70kg (150 lbs.)
• Compliments E5H Evaporating Distilled Water
• Standalone Solution for Impoundments
• Automated operation, reducing truck traffic
• Evaporates Pure Water Directly on Well Pad
• RFD Exemption for Evaporating Pure Water
10. Several Factor Determine Lease Pricing
◦ Number and locations of well pads
◦ Volume of Produced Water per pad
◦ TDS of Produced Water
◦ Reuse of concentrated brine or slurry disposal
If slurry disposal, distance from land fill or UIC well
◦ Term – 36 or 60 months preferred
◦ Service and warranty options
Tailored, cost effective service lease
Potential Savings of 20%-50% on other Produced
Water remediation options
(c) ESWS 2015
11. Technology is proven/proprietary
Experience Management Team
Pittsburgh, PA Based
20,000 Sq Ft Facility
Established 2009
Oil & Gas product launch 2013
(c) ESWS 2015
12. China Patent Approved
EU, USPO & Israel Initial Reviews Received
◦ Favorable Initial Review Comments
◦ Grant Expected within 3-6 months
Filed in 8 Regions/49 countries
(c) ESWS 2015
14. 4 Oil & Gas Customers
Significant other Major and Super Regional
E&P interest
Also International Interest
◦ China, Columbia, Australia, Middle East
(c) ESWS 2015
20. mg/L uS/cm Concentration (mg/L)
Description TSS TDS Conductivity Al Ca Fe Mg Mn K Na P Si Sulfur Cl
SOURCE INPUT WATER 171 76828 114600 2.78 6879 4.51 652 5.19 125 20860 0.20 2.24 10.8 47500
EPIPHANY OUTPUT WATER 2 36 133 0.87 1.32 0.05 0.14 0.05 0.34 11.8 0.10 0.32 1.14 14
The chart above shows that the raw ProducedWater contains approximately
7.5% total solids.After treatment by Epiphany’s system, the discharge water
is 99.98% pure (distilled).
(c) ESWS 2015
Editor's Notes
EXCO
Initial Revenue to Commence Oct 2014
Full service contract
SWN
2nd Phase training for SWN personnel
For sale of both E5H and ERM3000 Units
Shell
Engineering R&D Evaluation
CONSOL
Service Contract Extension
PDO
International Large Scale
Increasing Activity and Interest
From Super Majors, Majors and Others