1. Radhe Shyam Singh
7th
Floor, Flat No-704, Maruti Ganesh Apt.,Opp. Raj Palace ,Nani Daman-396210
radheshyamsingh.singh@gmail.com
9574814022
Abridgement
I look forward to a dynamic career in an organization, where I can learn and upgrade my knowledge and skills by achieving
organizational objectives, 4 years of experience in Machine maintenance, development, Spare management/Localisation,
Project handling and Quality Assurance
Bachelor of Technology with specialization in Electrical and Electronics engineering; Undergone Industrial training in
Mathura refinery; have worked on a curriculum project “Grid Connected Photovoltaic Energy Conversion and Tracking
System”; Good academic record & Good at learning and implementation.
Professional Experiences
Current employer
Currently Working as Electrical Maintenance Engineer at Anchor BY Panasonic a complete electrical solution provider
and offers a diverse range of products likes Wiring Devices, MCB, Fan, Lighting and Luminaries Since 21.09.2014
Role & Responsibility:-
Planning and effectuating preventive / condition based maintenance/ Predictive Maintenance schedules of
Various machineries and equipment to increase machine up time and equipment reliability.
Working with Centralized Energy Management System EnMS for continual improvements,Handling
Energy Monitoring System and power data analysis. EnMS steering committee member
Maintaining the monthly MIS Report, MTTR and MTBF as well as ISO 9001, ISO 14001 and ISO 50001
Maintenance relevant Documents.
Development and implementation of personnel training, including SOPs and SWIs, checklists, and
Instruction Books.
Handling the Calibration of process control equipment’s and adhering of Statuary compliance.
Adopting TPM and Kaizen (Continual Improvement) in all the process Machineries to improve Productivity.
HHH Management Sheet Preparation (Risk Assessment), Safety committee Member
Operations & Maintenance
Using Thermography & vibration analyser to predict the major break downs.
Identifying areas of obstruction / breakdowns and taking steps to rectify the equipment’s through application
of Troubleshooting tools.
Played an active role in the maintenance of transformers, APFC Panel, Relays, Air Circuit Breakers, Vacuum Circuit
Breakers, PCC/MCC, Current Transformers and Potential Transformer Testing.
Operation and Maintenance of Nitrogen injected Extruder line.
Maintenance of RBD m/c, MMH m/c, Extruder M/C, LATHE m/c, Mixer m/c, EOT Crane, Packing Line etc.
PLC: SIEMENS (S7-300, S7-200), AB RS Logix1200,Delta.
AC & DC Drive: SIEMENS, YASHKAWA, DELTA, ABB, AB.
Selection Criteria of Drive, Installation, Fault Analysis, Troubleshooting Control and Power Card, Configuration of
Parameter etc.
Checking or Troubleshooting of THYRISTOR and Bridges.
UTILITY (500kVA x 3 DGs with PLC based Auto synchronization, 11kV/433V Substation, Compressors, Chillers, RO &
DM Plant,).
Team Management
Leading, mentoring & monitoring the performance of team members to ensure efficiency in process operations and
meeting of production targets.
Creating and sustaining a dynamic environment that fosters development opportunities and motivates high performance
amongst team members.
Projects Handling
Erection & Commissioning of niehoff(Germany) made MMH
2. Erection & Commissioning of Domeks(Turkey) made PVC granules M/C
Erection & Commissioning of Johann Leimbach GmbH (Germany) Made high speed T/U.
Previous Employer
Worked as Electrical Maintenance Engineer at M/s ‘Zenium Cable LTD’ Udwada . A Wire & Cables Manufacturer, from
01.08.2012 to 20.09.2014
Notable Highlights
In process Testing of Jelly filled Co-Axial Cables like RG-6,RG-11,RG-59 .Spectrum Analysis of
Instrumentation Cables.
Carried out DC Conductor Resistance Test, Hot Set Test, Hot Deformation Test, Thermal Stability Test, Volume
Resistivity, Insulation Resistance Test, Flammability Test, High Voltage Test, Tensile Strength Test etc. Of Power
Cables.
Knowledge Enhancement Schedules
Delivered seminars on Nano Robotics and Hybrid Braking System at Integral University in 2010-11 .
Industrial visit at Larsen & Toubro (L&T) Lucknow during academic session also,
Industrial visit at NTPC Unchahar U.P during final year of academic session.
Academic Project
“Grid Connected Photovoltaic Energy Conversion and Tracking System”, the objective of the project is to design and
implement an automated single axis solar tracking mechanism in order to optimize the efficiency of overall solar energy
output. This project consists of both solar power and power obtained from grid, for an uninterrupted power supply.
Vocational Training
Performed 1 month Summer Training in IOCL, MATHURA REFINERY at CAPTIVE THERMAL POWER STATION with
capacity of 97.5 MW and visited:
Turbo generators (3 x 12.5 MW)
Gas Turbine Driven Generators (3 x 20.2 MW)
Boilers (3 x 150 T/Hr)
Heat Recovery Steam Generators (3 x 103 T/Hr)
IT Skills
Software Packages : Drive Monitor, Simatic Manager, Simatic Starter, SAP R/3- PM module,
MS Office (Word/PowerPoint/Excel)
Operating Systems : Windows 98/2000/XP/Vista/2007
Scholastics
B.Tech. in Electrical and Electronics Engineering from Integral University, Lucknow (2008-12) with average marks of
64.5%
Intermediate from Govt. Queen’s Inter College, Varanasi (UP Board) with 51.80% marks
High school from H. P. D. Jain School, Ara (BSEB) with 68.29% marks
Personal Dossier
Father’s name : Harendra Singh
D.O.B : 15/01/1990
Sex : Male
Nationality : Indian
Marital Status : Unmarried
Languages : English, Hindi .
Permanent Adress : Singh Bhawan Chandwa More, Ara, Bihar
Pin code-802312
Declaration
I do hereby declare that the information given above is true to the best of my knowledge and belief.