Saranraj K is an electrical engineer with over 6 years of experience in HVDC, FACTS, and AC systems commissioning, project execution, and management. He has worked on several large HVDC and power projects in India for Siemens and Inser Hitech. His experience includes commissioning of converter stations, testing equipment, coordinating with customers, and providing operations and maintenance support. He is skilled in commissioning various electrical equipment, control systems, protection schemes, and troubleshooting issues.
1. 1
CURRICULAM VITAE
SARANRAJ K
Mob : +919176328997
Email : saranraj.k@siemens.com
ksaran.22@gmail.com
Objective
To take a challenging role and apply my technical and Project Management skills to give an efficient and effective
solution that would help the organization to achieve the desired goals in the business and technology.
Skill Set
Electrical engineer with 6 years of experience in the domain of Control & Protection, Commissioning and Project
Execution of HVDC, FACTS & AC Systems.
Career Profile
I. Organization : SIEMENS LTD.
Division : EM-SG-SE.
Designation : HVDC Commissioning Engineer
Experience : From March-2013 to Till Now (2 Years 4 Months)
Assignment for HVDC Substation in Siemens LTD
1. ± 500KV, 2500 MW HVDC Bipolar Project Mundra to Haryana. (M/s.Adani Power Ltd)
2. 500MW, BACK TO BACK HVDC PROJECT, BANGLADESH (M/s. PGCB)
3. 6MTPA INTEGRATED STEELPLANT AT KALINGANAGAR (M/s. TATA Steel Ltd)
Experience:
Responsible for Activities related to Commissioning of AC yard, DC Yard, Pole & Station Control related
equipments, operational experience in Valve cooling and auxiliary Systems.
Hands-on experience in overall operations of HVDC systems, including fault Analysis during trip conditions, &
bringing back the system to normal, under online guidance.
Having good exposure in service pack updates, WINCC updates, and operations of DC HMI.
Skilled in SIMATIC TDC for modifications, software updates & Fault analysis in Pole control, station control and
AC Filter Protection.
Skilled in TFR Analysis via Iba analyzer & experience in Iba PDA, and Iba data co-coordinator software.
Having exposure in pre-commissioning & Subsystem testing of DC equipments like current measuring device &
voltage divider, DC Filter.
Having Experience in thyristor valve and it’s control module replacement and valve hall equipment replacing and
servicing.
Having exposure in pre-commissioning & Subsystem testing of AC equipments like CT, CVT, VT, CB, Converter
transformer & AC Filter.
Co-ordinate with After Sales Management for warranty and Operation & maintenance Support to Customer for
smooth operation and followed site activities.
2. 2
Testing, Servicing and replacement works of PEMO cards, LFL cards and fault error analysis with help of online
support from after sales Expert.
Having good experience with testing kit like Omicron and KoKos, Megger.
Having Experience of site administration and handling of all issues related to site, material hand over, trouble
shooting of the system related issues and faults, Punch points attending and giving online support to customer for
system related issues.
Co-ordination with end customer for protocol and other documentation work. Handing over of test equipment and
systems to customer after final testing and approval.
Co- ordination with expert engineering team for any modification or change implementation required at site to
achieve the desired results as per customer requirements.
Preparing the maintenance plan for shutdown and the same implementing with group of engineer and technician.
II. Organization : INSER HITECH PVT LTD
Designation : Sr. Commissioning Engineer
Period : June-2009 to Dec -2012
Experience : 3.5Years
Domestic Assignment for HVDC and GIS Substations & Power Plants in INSER HITECH PVT LTD:
1. M/s. Adani Power LTD, (2500MW,+-500KV HVDC Substation Mundra, Gujarat)
2. M/s. Delhi Metro Rail Corporation LTD, (25KV substation Airport Express Line, New Delhi)
3. M/s. Delhi Metro Rail Corporation LTD, (66/33/25KV GIS, Mahipalpur, New delhi)
4. M/s. Power Grid Corporation of India Ltd, (400/220 KV GIS, Meenjoor, Chennai).
5. M/s. Power Grid Corporation of India Ltd, (400/220KV Power Grid Automation Switchyard, Hiriyur, Bangalore)
6. M/s. Cairn Energy India Pvt. Ltd, (4x12MW Steam Power plant (Oil and Gas), Barmer, Rajasthan)
7. M/s. PENNA ELECTRICITY LTD, (2x17MW Gas Power plant, Ramanathapuram, Tamilnadu)
8. M/s. Karnataka Power Transmission Corporation LTD. (220/66/11KV GIS, Meyuhal, Bangalore)
9. M/s. J&K State Power Development Corporation LTD.(132/33KV Automation Substation, Simli, Jammu Kashmir)
10. M/s. Reliance Energy India Pvt LTD. (4x300MW Thermal Power plant(CHP Plant),Rosa,UttarPrathesh)
Experience:
Testing and Commissioning of DC yard equipments like Current Measuring Devise and DC filter Capacitors and
its protection circuit, Isolators, Breakers and voltage divider.
Testing and Commissioning of AC yard equipments like AC filter Capacitors, Resister bank and inductor then its
protection circuit scheme.
Testing and commissioning of 400KV Switchyard equipments like current and voltage transformers, CVT,
transformers, isolators, circuit breakers & relays, including with the Scheme checking of the control panel
Testing and Commissioning of Convertor transformer, High voltage Bushing of valve hall and smoothing reactor.
Testing and commissioning of Power plant equipments like Motors with its Cable Hi-pot testing, LT panels, HT
panels and its parts, Station, Auxiliary, Generating Transformer. Remote Control of Tap changer of GT.
Testing and commissioning of panels ranging from 415V to 33 HT switchgear LT switchgear which includes
Scheme checking & trouble shooting.
3. 3
Testing and Commissioning of GIS Substation equipment and its control panel checking & Trouble shooting
ranging from 25KV to 400KV.
Testing and Commissioning Of UPS ranging from 5KV to 80KVA which include with Scheme check and trouble
shooting.
Attending technical discussion with client & consultant and modification according to the customer & system
requirement
Co-ordination with testing of latest numerical relays of EHV lines, bus bars and transformer protection.
Knowledge of Generator Protection, Transformer protection, Transformer Differential Protection & REF
Protection, Bus Bar protection, Motor protection, and synchronizing scheme
III. Organization : READY POWER SERVICES
Designation : Supervisor
Period : April 2006 to April 2007(1 Year)
Experience:
Operation, Maintenance and Services of Diesel Generator rated up to 1500KV in various sites across over TAMIL
NADU.
Fire Fighting system operation and Maintenance in NOKIA and ITC Ltd.
Professional Qualification
Degree : Diploma Engineering,
Discipline : Electrical & Electronics
Percentage : 92%
Graduation : 2009
College : Elumalai Polytechnic College, Villupuram
University : Department of Technical Education Chennai.
Personal Details
Father Name : Krishnan S
Date of Birth : 17/08/1989
Nationality : Indian
Gender : Male
Marital Status : Single
Blood Group : B+VE
Languages Known : Tamil, English, and Hindi
Address : 4/36P,Marriyamman kovil street,Poond,Vembi(Post),Villupuram District.
Tamilnadu,India-605203
Declaration
I hereby declare that the above information furnished by me is to the best of my knowledge and belief.
PLACE:
DATE : 30 /06/2015 SARANRAJ.K