Introduction to
Peakvue
Objectives
 To Understand:
– 1. What Peakvue Is!
– 2. How it Works!
– 3. Filter Options
• Types of filters available
• Calculating the correct filter setting
• Filter Guidelines
– 4. Peakvue Data
• Spectrums and Waveforms
• Diagnosing Faults
– 5. Peakvue Versus Demodulation Techniques
– 6. Acquiring Peakvue Data using the 2120A
What is Peakvue™
 What is Peakvue?
– Peakvue is a technology unique to CSI and means ‘Peak Value’
– Such as the Peak Value of an impact generated by a bearing defect in a
time waveform - (True Peak Value)
– If you have a 21XX analyzer you have the capability to acquire
‘Peakvue Data’
 These stress waves travel further than conventional vibration signals
so a truer indication of fault severity is obtained.
 The ‘True Peak Value’ is obtained by concentrating on ‘Stress Wave
Analysis’ rather than conventional vibration data.
Initial Impact
What is Peakvue™
 What is a Stress Wave?
 Stress waves accompany metal-metal impacting. These stress waves
are short-term (fractional to a few milliseconds) transient events,
which introduce a ripple effect on the surface machinery as they
propagate away from the initial event.
– If you think of a stone being dropped into a pool of water. The stone is
the initial impact generated by the fault. The effect of the stone being
dropped into the water cause a ripple on the surface of the water which,
spreads over a wide area.
What is Peakvue
 If a bearing has a sub-surface defect (early bearing wear), when a
rolling element passes over the defect it bends the race slightly and
then as the rolling element passes it restores back to it’s natural state.
 This event causes a high frequency (1-50KHz) short duration stress
wave.
 This is what Peakvue detects
How Does It Work?
 A comparison can be made of the sampling to show how data is
collected through both methods of data acquisition, normal and
Peakvue™.
FFT
High
Pass
Filter
Full
Wave
Rectify
Digital
Peak
Impact
Detection
Vibration
Signal
How Does It Work?
 The diagram below shows sampling of data using normal data
collection.
Stress wave- this is missed
under normal conditions
Instantaneous Samples
Peakvue Samples
How Does It Work?
 The diagram below shows sampling of data using Peakvue™ data
collection.
Stress wave- this is missed
under normal conditions
How Does It Work?
 Peakvue measures the highest amplitude found in a stress waves
(Pk Value) and holds that data
 The waveform data is then passed through a high pass filter to
remove the unwanted, low frequencies
– Imbalance, Misalignment, Looseness, resonance etc.
 This just leaves us with the high frequency impacting data
(Peak) above the machine noise level
 The data is then brought back to fundamental frequency. (this
allows analysis of the data to be done quicker and easier)
Filters
Types of filter available
Filter Calculations
Filter Guidelines
 Selecting the wrong type of filter will result in poor quality data
– To much noise filtered through (the spectrum becomes very noisy)
– To much is filtered out (The stress wave is not allowed to pass through)
Filters Options
 There are two types of filter options in Peakvue, these are:
– 1. Band Pass Filter
– 2. High Pass Filter
 Each of the filters are designed to remove unwanted data out of the
signal at the appropriate levels
 One of the key elements in acquiring meaningful peakvue data is the
selection of ‘filters’
Filter Options - ‘High Pass Filter’
 High Pass Filters remove all frequencies from the data below the filter
setting but allow the high frequency stress wave to pass through.
All low frequencies
are removed from
the input signal
Stress Wave data is allowed
to pass through the filter
High Pass Filter
Filter Options - ‘Band Pass Filters’
 Looks for stress waves within a parameter defined by the filter setting.
Frequencies above and below this setting are removed from the data
Data is
filtered out
of the signal
Data is
filtered out
of the signal
Data passes
through filter
Filter Selection
 To select the correct filter we need to consider the highest operational
defect frequency that we want to measure/detect. Then select the next
available filter above that frequency
 E.g.
– Consider a typical motor / pump arrangement. We have:
• 1 - 4 Pole A.C. Induction Motor
• 2 - 3 Jaw Coupling
• 3 - Centrifugal Pump
– Typically the highest defect frequency to emit from this machine would
be?
• 1 - BPFI - Bearing Defect
Filter Selection
 4 Pole Motor A.C Induction fitted with bearings SKF 6313
– Defect Frequencies (Orders)
• FTF - 0.384
• BSF - 2.037
• BPFO - 3.071
• BPFI - 4.929
 Typically we would want to see the 10th Harmonic of the BPFI
– Highest defect frequency:
• (BPFI x 10) x Turning Speed (Hz)
• (4.929 x 10) x 25
• 1232.3 Hz
– We would then select the next available filter setting above the frequency
Available filters
 High Pass Filters
– 500hz
– 1000hz
– 2000hz
– 5000hz
– 10000hz
– 20000hz
 Band Pass Filters
– 20hz – 150hz
– 50hz – 300hz
– 100hz – 600hz
– 500hz – 1khz
Note: the meter will only allow you to select the next
filter above the specified Fmax.
From our previous calculation of 1232Hz, What filter setting would we select?
Filter uses (Band Pass) - Guidelines
 Band Pass Filters
– 20hz – 150hz Felt problems on paper machines
– 50hz – 300hz Certain structural resonance excitation,
modulation of gearmesh in low speed machinery
– 100hz – 600hz Gearmesh modulation in intermediate
speed machinery.
– 500hz – 1khz Gearmesh modulation
Tip: use bandpass filters when the event of interest is the
excitation of a structural resonance, or the modulation of
known frequencies – such as gearmesh.
Filter uses (Highpass) - guidelines
 High Pass filters
– 500hz Low speed machinery having <125hz. Bearing & gearing problems
– 1000hz Intermediate speed machinery (<2000 rpm) with gear mesh <300hz
– 2000hz Medium speed machinery (<4000rpm) with gear mesh ,600hz
– 5000hz Machinery up to 9000rpm and gear mesh to 1500hz, Requires attention be
paid to how the sensor is mounted as well as the sensors frequency response.
– 10000hz High speed machinery with gear mesh up to 3000hz sensor must be
permanently mounted with a frequency response of 3db in the 30kHz or higher
range.
– 20000hz High speed machinery with gearmesh up to 6000hz. Sensor must be high
frequency and permanently mounted.
Tip: Use highpass filters when the objective is to detect stress
waves which are emitted by metal on metal impacting.
Filter Selection - Question
 Consider:
– Motor running at a speed of 1000RPM
– Driving a fan unit via pulley belts
– Fan Speed is 1350RPM
• Motor Bearings = SKF 3095 - BPFI 4.855
• Fan Bearings = SKF 6210 - BPFI 5.907
 Calculate what Filter setting would be required for both the motor
and the fan bearings?
– Filters Available:
• 500 Hz, 1000Hz, 2000Hz, 5000Hz, 10000Hz, 20000Hz. (High Pass)
• 20-150Hz, 50-300Hz, 100-600Hz, 500-1KHz. (Band Pass)
Filter Selection - Answers
 Motor Speed = 1000CPM / 60 = 16.667Hz
 Fan Speed = 1350CPM / 60 = 22.5Hz
 Motor.
– BPFI = 4.855
– Defect Frequency = (BPFI x 10) x Turning Speed (Hz)
– Defect Frequency = (4.855 x 10) x 16.667
– Defect Frequency = 809.18 Hz
 Filters Available:
• 500 Hz, 1000Hz, 2000Hz, 5000Hz, 10000Hz, 20000Hz. (High
Pass)
• 20-150Hz, 50-300Hz, 100-600Hz, 500-1KHz. (Band Pass)
1000Hz
Filter Selection - Answers
 Motor Speed = 1000CPM / 60 = 16.667Hz
 Fan Speed = 1350CPM / 60 = 22.5Hz
 Fan
– BPFI = 5.907
– Defect Frequency = (BPFI x 10) x Turning Speed (Hz)
– Defect Frequency = (5.907 x 10) x 22.5
– Defect Frequency = 1329.07Hz
 Filters Available:
• 500 Hz, 1000Hz, 2000Hz, 5000Hz, 10000Hz, 20000Hz. (High
Pass)
• 20-150Hz, 50-300Hz, 100-600Hz, 500-1KHz. (Band Pass)
2000Hz
Peakvue Data
Spectrums and Waveforms
Diagnostics Techniques
Peakvue - Spectrum
 Here is a typical Peakvue spectra plot.
 This is typically a GOOD spectrum
1. Broad band energy
- Filtered Noise
2. Units should be ‘acceleration’
(Very high frequency analysis)
3. Amplitude values are low.
Severity of fault is not
determined in the spectra
Peakvue - Spectrum
 This is a Peakvue spectrum where high frequency stress waves are
being detected
1. Broad band energy
- Filtered Noise
2. Units still in ‘acceleration’
(Very high frequency analysis)
3. Amplitude values are low.
Remember severity of fault is
not determined in the spectra
Notice the Impacts
passing through the
filtered noise
 This is indication of a fault developing
Peakvue - Waveforms
 Waveforms can be confused with spectrums, as the waveform is only
plotting the peak value and does not show a full wave.
A1 - Example 1
EX 1 -D3P Tail Roll Non D/S Peakv ue
Label: Easy
Analyz e W av eform
16-Mar-01 12:03:14
(PkVue- HP 500 Hz)
PK = .0556
LOAD = 100.0
RPM = 80.
RPS = 1.33
PK(+) = .5599
PK(-) = .0397
CRESTF= 14.25
0 3 6 9 12
-0.1
0
0.1
0.2
0.3
0.4
0.5
0.6
Rev olution Number
Acceleration
in
G-s
1. Filtered Noise Level
2. Peak Value Impacts
3. No Peak Negative Value
4. Acceleration
as default units
Peakvue - Diagnostics
 Diagnosing a Peakvue spectrum and waveform is not to dissimilar to
that of conventional data.
 However there are a few differences which can be a bit confusing at first,
these are:
– 1. Do not try to locate 1xTurning Speed, as this is low frequency data and
will be filtered out.
• Turning speed should be entered using the conventional spectral data.
– 2. Multiple harmonics are often present within a spectrum due to the way
peakvue samples the data.
• These do not indicate ‘Looseness’
– 3. Spectral amplitudes are always low in amplitude but should not be used
to judge severity. Use the spectrum to diagnose the fault.
– 4. Waveforms indicate the severity of the problem.
Peakvue - Diagnostics
 Continued…..
– 5. Ensure the same filter setting is used in both the spectrum and
waveform.
• Potential faults can be missed or overlooked if different filters are used.
– 6. Cage Defects show up well in peakvue data and is normally an
indication the bearing is under stress.
– 7. All low frequency faults are removed from the data and will not be seen
in a Peakvue spectrum and waveform
• Imbalance, Misalignment, Looseness, Resonance - All Gone.
Peakvue - Diagnostics
1.Spectral data indicating a
defect at 5.463 Orders
2. Impacting also being
detected at 0.6G-s
3. Very Slow
RPM
Peakvue - Diagnostics
4.Fault Frequencies Indicate
a BPFI Defect
Peakvue™ Amplitudes -
Rolling Element Bearings
 For machines running between speeds of 900 - 3600RPM
recommended guidelines for setting initial warning levels in the
Peakvue™ time - waveform are as follows:
Alert Value Fault Value
Inner Race 3.0g's 6.0g's
Outer Race 6.0g's 12.0g's
Rolling elements fault 4.5g's 9.0g's
Cage frequencies If evident then the bearing is usually under
stress.
Peakvue™ Amplitudes -
Rolling Element Bearings
 For machines running at speeds <900RPM recommended guidelines
for setting initial warning levels in the Peakvue™ time- waveform are as
follows:
3
2.7
2.5
2.2
1.9
1.6
1.3
1.0
0.6
0.5
0.3
0.1
6
5.5
5.0
4.4
3.9
3.3
2.6
1.9
1.2
0.9
0.5
0.2
4.5
4.1
3.7
3.3
2.9
2.4
2.0
1.5
0.9
0.7
0.4
0.2
0
1
2
3
4
5
6
7
900
800
700
600
500
400
300
200
100
75
35
10
Inner race -
Amplitude (g's)
Outer race -
Amplitude (g's)
Rolling elements -
Amplitude (g's)
Levels for concern for machines running below 900 RPM
RPM
Acceleration
g's
Peakvue Vs
Demodulation
Peakvue Vs Demodulation
 What is Demodulation?
– This is a technique which concentrates on stress wave analysis, but is
not as effective.
 How Does it Work?
– Demodulation looks for the ringdown that follows an impact, and tries to
measure how quickly it fades. In order to do this the ‘Time Waveform’
has to be manipulated in such away that the waveform data becomes
useless
Less than 1ms Initial Impact
Ringdown
Peakvue Vs Demodulation
 What are the Differences?
– Peakvue samples the data much quicker enabling it to catch the very
short duration high frequency stress wave. It then holds that ‘Peak
Value’ throughout its parameter.
– Due to the Analogue filtering system used by Demodulation, results in a
‘delay in response’ and the stress wave impact is missed
Demodulation registers Peak Impact Detection registers
Peakvue Vs Demodulation
High
Pass
Filter
Full
Wave
Rectify
Digital
Peak
Impact
Detection
FFT
Peak Impact Detection
High
Pass
Filter
Low
Pass
Filter
Full
Wave
Rectify
Remove
DC
Bias
A/D
Converter
FFT
Standard Demodulation
Enveloping Stage
The Process!
Peakvue Vs Demodulation
 Case Study.
– Equipment
• A conveyor system consisting of six rolls is driven by a motor/gearbox unit (GMU).
• The motor speed is 1500RPM reduced through the gearbox giving the roller
speed to be 98.5RPM
Peakvue Vs Demodulation
 Data was collected on each bearing of the conveyor system
• Due to the slow speeds Peakvue and Demodulation Filters were both set to
500Hz High Pass using 1600 Lines of Resolution
Pv D - Example 1
Ex1 -R1P Roller Bearing Driv e End
Label: Demodulated 500Hz High Pass
Analyz e Spectrum
18-Dec-01 14:22:30
(Demod- HP 500 Hz )
PK = .0295
LOAD = 100.0
RPM = 97.
RPS = 1.62
0 50 100 150 200
0
0.004
0.008
0.012
0.016
Frequency in Hz
PK
Acceleration
in
G-s
Demodulation Spectra
Pv D - Example 1
Ex1 -R1P Roller Bearing Driv e End
Label: Peakv ue 500Hz High Pass
Analyz e Spectrum
18-Dec-01 14:10:26
(PkVue- HP 500 Hz)
PK = .1238
LOAD = 100.0
RPM = 99.
RPS = 1.64
0 50 100 150 200
0
0.01
0.02
0.03
0.04
0.05
0.06
0.07
Frequency in Hz
PK
Acceleration
in
G-s
Peakvue Spectra
PK
Acceleration
in
G-s
Frequency in Hz
Pv D - Example 1
Ex1 -R1P Roller Bearing Driv e End (18-Dec-01)
0 50 100 150 200
0
0.01
0.02
0.03
0.04
0.05
Max Amp
.0490
14:10: 26
18-Dec-01
14:10: 26
18-Dec-01
Direct Comparison
Between the Two
Peakvue
Demodulation
Peakvue Vs Demodulation
Pv D - Example 1
Ex1 -R1P Roller Bearing Driv e End
Rev olution Number
Acceleration
in
G-s
0 1 2 3 4 5 6 7
Plot
Span
-0.2
1.0
18-Dec-01 14: 10
18-Dec-01 14: 22
Peakvue Waveform
Demodulation
Waveform
Acquiring Peakvue
Data
Setting up the 2120A
Creating a Peakvue AP Set
Setting up the 2120A
 Peakvue can be accessed from the ‘Analysis Expert’ options found
among the command keys of the 2120A
 There are two ways of acquiring peakvue data within the 2120A
– Bearing/Gear Analysis - Peakvue
• Preset to acquire Peakvue data based upon the AP set assigned to the
machine
– User Setup Option
• Allows user interface to define their own parameters
Setting up the 2120A
 User Set-up Option
– Define the Fmax you wish to go to. Remember the Fmax is going to
define your filter setting.
• 0 - 30 KCPM = 500Hz High Pass
• 30 - 60 KCPM = 1000Hz High Pass
• 60 - 120 KCPM = 2000Hz High Pass
• 120v - 300 KCPM = 5000Hz High Pass
 Lines of Resolution
– These have to be good enough to capture the FTF of a bearing, which
would equate to around 15 Revolutions of waveform data.
• Number of Revs = Number of lines / Fmax(Orders)
– E.g. 800 Lines over an Fmax of 60 Orders = 13.3 Revolutions (Inadequate)
– 1600 Lines over an Fmax of 60 Orders = 26.6 Revolutions (OK)
Setting up the 2120A
 Averages
– This has to be set to 1 Average to gain the ‘true peak’ value.
• If you start averaging the data then a stress wave detected in the first average
that is not there in the second will lose it’s true amplitude when averaged
together.
 By using the ‘Page Down’ Button we can toggle through the pages until
we find our Peakvue Options (Page 4 of 4)
– We turn Peakvue to ‘Yes’
– The Pre-filter can now be changed to our required HP Setting
 Units
– The default unit for peakvue is ‘Acceleration’. Remember we are trying to
detect very high frequency events, well above conventional vibration data.
Acceleration accentuates high frequencies.
• Sensor units can be used if using an accelerometer, however CSI recommend
a minimum mounting of a ‘Rare Earth Magnet’ for data collection
Setting up the 2120
 Data collection can now commence.
 Check the data once collection has finished
– Look for:
• Impacts in both spectrum and waveform
• Amplitude levels of the Waveform
• quality of the data
– If a problem is detected you may want to acquire more data with a
different filter setting.
– Remember to store the data once the reading has been taken
 At least one Peakvue point should be applied to each critical machine to
detect early bearing wear, gearwear or adverse metal to metal contact.
– This will need building in the database and adding to the route
Peakvue™
Analysis Parameter Setup
Mastertrend and RBMware
1. Open Database Management
2. Select Analysis Parameter
Peakvue™ AP Set up I
Peakvue™ AP Set up II
1. Complete the spectrum setup, specifying
Fmax, LOR and averages (1).
2. Specify the number of parameters - 2
Peakvue™ AP Set up III
1. Check, ‘Use Analog pre-processor
2. Select Peakvue, under the ‘Envelope
Demodulator’
3. Select the filter setting.
Peakvue™ AP Set up IV
1. Uncheck, ‘obtain special time
waveform?’ - As Default units will be
acceleration
2. Discard all settings when this is
unchecked
Peakvue™ AP Set up V
1. Complete Analysis Parameter
specifications, the most important parameter
is the ‘peak to peak’ waveform parameter.
2. Ensure ‘unit type’ is acceleration
Gearbox case study
Diagram
G1
G3
G4
G5
G6
G7
G8
G9
G10
G11
G12
M1
M2
Introduction
 The above gearbox had been overhauled in the workshop and
was on its final test run. A vibration signature was taken to
confirm a small knock believed to be coming from the coupling,
and prove the gearbox was OK.
 The readings were taken using Peakvue and standard
Vibration Technology on the corresponding points indicated in
the diagram above. The following spectrum where obtained.
Standard Data
The standard spectrum below was taken from G5. Is there a Problem?
G1
G3
G4
G5
G6
G7
G8
G9
G10
G11
G12
M1
M2
The Peakvue reading shows distinct energy at 6.941 Hz and
multiple harmonics of this which is the running speed of the
third shaft. The bottom waveform shows clearly a substantial
impacting of up to 12 G’s occurring each revolution.
PeakVue™ Data
The fault
 The diagram below indicates the location of the suspected gear fault
and was diagnosed as possibly a damaged tooth
G1
G3
G4
G5
G6
G7
G8
G9
G10
G11
G12
M1
M2
Faulty Gear
• When the gearbox was re-stripped and examined a cracked
tooth on the gear identified was found.

More Related Content

What's hot

INSTRUMENTACIÓN INDUSTRIAL.pdf
INSTRUMENTACIÓN INDUSTRIAL.pdfINSTRUMENTACIÓN INDUSTRIAL.pdf
INSTRUMENTACIÓN INDUSTRIAL.pdfJuanPerez170515
 
autonomous-maintenance-training-pack.pptx
autonomous-maintenance-training-pack.pptxautonomous-maintenance-training-pack.pptx
autonomous-maintenance-training-pack.pptxssuser6dba3d
 
Microprocessor applications
Microprocessor applicationsMicroprocessor applications
Microprocessor applicationsRohit Gothwal
 
Wecon HMI PI Series Q&A
Wecon HMI PI Series Q&AWecon HMI PI Series Q&A
Wecon HMI PI Series Q&ALily Zheng
 
classic control and PLC training report
classic control and PLC training reportclassic control and PLC training report
classic control and PLC training reportahmed abdelnasser
 
taller de investigacion 1.U1.tipos de investigacion
taller de investigacion 1.U1.tipos de investigaciontaller de investigacion 1.U1.tipos de investigacion
taller de investigacion 1.U1.tipos de investigacionYaby M
 

What's hot (10)

INSTRUMENTACIÓN INDUSTRIAL.pdf
INSTRUMENTACIÓN INDUSTRIAL.pdfINSTRUMENTACIÓN INDUSTRIAL.pdf
INSTRUMENTACIÓN INDUSTRIAL.pdf
 
Condition monitoring
Condition monitoringCondition monitoring
Condition monitoring
 
Manual st10 flash-pro-usb (1)
Manual st10 flash-pro-usb (1)Manual st10 flash-pro-usb (1)
Manual st10 flash-pro-usb (1)
 
autonomous-maintenance-training-pack.pptx
autonomous-maintenance-training-pack.pptxautonomous-maintenance-training-pack.pptx
autonomous-maintenance-training-pack.pptx
 
Microprocessor applications
Microprocessor applicationsMicroprocessor applications
Microprocessor applications
 
What is a CMMS?
What is a CMMS?What is a CMMS?
What is a CMMS?
 
SISTEMAS DE CONTROL
SISTEMAS DE CONTROLSISTEMAS DE CONTROL
SISTEMAS DE CONTROL
 
Wecon HMI PI Series Q&A
Wecon HMI PI Series Q&AWecon HMI PI Series Q&A
Wecon HMI PI Series Q&A
 
classic control and PLC training report
classic control and PLC training reportclassic control and PLC training report
classic control and PLC training report
 
taller de investigacion 1.U1.tipos de investigacion
taller de investigacion 1.U1.tipos de investigaciontaller de investigacion 1.U1.tipos de investigacion
taller de investigacion 1.U1.tipos de investigacion
 

Similar to Intro-Peakvue.pdf

Color flow medical cardiac ultrasound
Color flow medical cardiac ultrasoundColor flow medical cardiac ultrasound
Color flow medical cardiac ultrasoundLarry Miller PhD
 
Präsentatiom über Vibration-Analysis-Ppt.pdf
Präsentatiom über Vibration-Analysis-Ppt.pdfPräsentatiom über Vibration-Analysis-Ppt.pdf
Präsentatiom über Vibration-Analysis-Ppt.pdfPatrickFo1
 
Vibration analysis unit 4
Vibration analysis unit 4Vibration analysis unit 4
Vibration analysis unit 4Dibyendu De
 
Vibration Monitoring-Vibration Transducers-Vibration Troubleshooting
Vibration Monitoring-Vibration Transducers-Vibration TroubleshootingVibration Monitoring-Vibration Transducers-Vibration Troubleshooting
Vibration Monitoring-Vibration Transducers-Vibration TroubleshootingDhanesh S
 
introduction_to_medical_imaging
introduction_to_medical_imagingintroduction_to_medical_imaging
introduction_to_medical_imagingrezgar Shahi
 
Unit 6: DSP applications
Unit 6: DSP applicationsUnit 6: DSP applications
Unit 6: DSP applicationsMinakshi Atre
 
Oscilloscope Fundamentals, Hands-On Course at EELive 2014
Oscilloscope Fundamentals, Hands-On Course at EELive 2014Oscilloscope Fundamentals, Hands-On Course at EELive 2014
Oscilloscope Fundamentals, Hands-On Course at EELive 2014Rohde & Schwarz North America
 
ECG Signal Denoising using Digital Filter and Adaptive Filter
ECG Signal Denoising using Digital Filter and Adaptive FilterECG Signal Denoising using Digital Filter and Adaptive Filter
ECG Signal Denoising using Digital Filter and Adaptive FilterIRJET Journal
 
Unit 6: DSP applications
Unit 6: DSP applications Unit 6: DSP applications
Unit 6: DSP applications Minakshi Atre
 
Vibration Measurements In Wind Power Turbines
Vibration Measurements In Wind Power TurbinesVibration Measurements In Wind Power Turbines
Vibration Measurements In Wind Power Turbinesalexzio
 
An Introduction to RF Design, Live presentation at EELive 2014
An Introduction to RF Design, Live presentation at EELive 2014An Introduction to RF Design, Live presentation at EELive 2014
An Introduction to RF Design, Live presentation at EELive 2014Rohde & Schwarz North America
 
Datasheet Fluke 43B. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 43B. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke 43B. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 43B. Hubungi PT. Siwali Swantika 021-45850618PT. Siwali Swantika
 
MOTOR online PD test IRIS Presentation 2017 rev1.pptx
MOTOR online PD test IRIS Presentation 2017 rev1.pptxMOTOR online PD test IRIS Presentation 2017 rev1.pptx
MOTOR online PD test IRIS Presentation 2017 rev1.pptxamrgharib12
 
Digial instrumentation fnal
Digial instrumentation fnalDigial instrumentation fnal
Digial instrumentation fnalBishal Rimal
 
MOTOR online PD test IRIS Presentation 2017 rev1.pptx
MOTOR online PD test IRIS Presentation 2017 rev1.pptxMOTOR online PD test IRIS Presentation 2017 rev1.pptx
MOTOR online PD test IRIS Presentation 2017 rev1.pptxamrgharib12
 
RIGOL Real-time spectrum analyzer RSA5000 Series
RIGOL Real-time spectrum analyzer RSA5000 SeriesRIGOL Real-time spectrum analyzer RSA5000 Series
RIGOL Real-time spectrum analyzer RSA5000 SeriesNIHON DENKEI SINGAPORE
 

Similar to Intro-Peakvue.pdf (20)

Color flow medical cardiac ultrasound
Color flow medical cardiac ultrasoundColor flow medical cardiac ultrasound
Color flow medical cardiac ultrasound
 
Präsentatiom über Vibration-Analysis-Ppt.pdf
Präsentatiom über Vibration-Analysis-Ppt.pdfPräsentatiom über Vibration-Analysis-Ppt.pdf
Präsentatiom über Vibration-Analysis-Ppt.pdf
 
Vibration analysis unit 4
Vibration analysis unit 4Vibration analysis unit 4
Vibration analysis unit 4
 
Vibration Monitoring-Vibration Transducers-Vibration Troubleshooting
Vibration Monitoring-Vibration Transducers-Vibration TroubleshootingVibration Monitoring-Vibration Transducers-Vibration Troubleshooting
Vibration Monitoring-Vibration Transducers-Vibration Troubleshooting
 
introduction_to_medical_imaging
introduction_to_medical_imagingintroduction_to_medical_imaging
introduction_to_medical_imaging
 
Unit 6: DSP applications
Unit 6: DSP applicationsUnit 6: DSP applications
Unit 6: DSP applications
 
Oscilloscope Fundamentals, Hands-On Course at EELive 2014
Oscilloscope Fundamentals, Hands-On Course at EELive 2014Oscilloscope Fundamentals, Hands-On Course at EELive 2014
Oscilloscope Fundamentals, Hands-On Course at EELive 2014
 
ECG Signal Denoising using Digital Filter and Adaptive Filter
ECG Signal Denoising using Digital Filter and Adaptive FilterECG Signal Denoising using Digital Filter and Adaptive Filter
ECG Signal Denoising using Digital Filter and Adaptive Filter
 
Unit 6: DSP applications
Unit 6: DSP applications Unit 6: DSP applications
Unit 6: DSP applications
 
Vibration Measurements In Wind Power Turbines
Vibration Measurements In Wind Power TurbinesVibration Measurements In Wind Power Turbines
Vibration Measurements In Wind Power Turbines
 
An Introduction to RF Design, Live presentation at EELive 2014
An Introduction to RF Design, Live presentation at EELive 2014An Introduction to RF Design, Live presentation at EELive 2014
An Introduction to RF Design, Live presentation at EELive 2014
 
Datasheet Fluke 43B. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 43B. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke 43B. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 43B. Hubungi PT. Siwali Swantika 021-45850618
 
dsp dip.pptx
dsp dip.pptxdsp dip.pptx
dsp dip.pptx
 
3920 Assn_1
3920 Assn_13920 Assn_1
3920 Assn_1
 
MOTOR online PD test IRIS Presentation 2017 rev1.pptx
MOTOR online PD test IRIS Presentation 2017 rev1.pptxMOTOR online PD test IRIS Presentation 2017 rev1.pptx
MOTOR online PD test IRIS Presentation 2017 rev1.pptx
 
Digial instrumentation fnal
Digial instrumentation fnalDigial instrumentation fnal
Digial instrumentation fnal
 
MOTOR online PD test IRIS Presentation 2017 rev1.pptx
MOTOR online PD test IRIS Presentation 2017 rev1.pptxMOTOR online PD test IRIS Presentation 2017 rev1.pptx
MOTOR online PD test IRIS Presentation 2017 rev1.pptx
 
signal.ppt
signal.pptsignal.ppt
signal.ppt
 
Rf sys ppt tx and rx 1
Rf sys ppt tx and rx 1Rf sys ppt tx and rx 1
Rf sys ppt tx and rx 1
 
RIGOL Real-time spectrum analyzer RSA5000 Series
RIGOL Real-time spectrum analyzer RSA5000 SeriesRIGOL Real-time spectrum analyzer RSA5000 Series
RIGOL Real-time spectrum analyzer RSA5000 Series
 

Recently uploaded

Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxDeepakSakkari2
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingrakeshbaidya232001
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024hassan khalil
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxJoão Esperancinha
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVRajaP95
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerAnamika Sarkar
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escortsranjana rawat
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSRajkumarAkumalla
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxupamatechverse
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Dr.Costas Sachpazis
 
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...ZTE
 
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSCAESB
 
Analog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog ConverterAnalog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog ConverterAbhinavSharma374939
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)Suman Mia
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINESIVASHANKAR N
 

Recently uploaded (20)

Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptx
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptx
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
 
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentation
 
Analog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog ConverterAnalog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog Converter
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
 
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
 

Intro-Peakvue.pdf

  • 2. Objectives  To Understand: – 1. What Peakvue Is! – 2. How it Works! – 3. Filter Options • Types of filters available • Calculating the correct filter setting • Filter Guidelines – 4. Peakvue Data • Spectrums and Waveforms • Diagnosing Faults – 5. Peakvue Versus Demodulation Techniques – 6. Acquiring Peakvue Data using the 2120A
  • 3. What is Peakvue™  What is Peakvue? – Peakvue is a technology unique to CSI and means ‘Peak Value’ – Such as the Peak Value of an impact generated by a bearing defect in a time waveform - (True Peak Value) – If you have a 21XX analyzer you have the capability to acquire ‘Peakvue Data’  These stress waves travel further than conventional vibration signals so a truer indication of fault severity is obtained.  The ‘True Peak Value’ is obtained by concentrating on ‘Stress Wave Analysis’ rather than conventional vibration data.
  • 4. Initial Impact What is Peakvue™  What is a Stress Wave?  Stress waves accompany metal-metal impacting. These stress waves are short-term (fractional to a few milliseconds) transient events, which introduce a ripple effect on the surface machinery as they propagate away from the initial event. – If you think of a stone being dropped into a pool of water. The stone is the initial impact generated by the fault. The effect of the stone being dropped into the water cause a ripple on the surface of the water which, spreads over a wide area.
  • 5. What is Peakvue  If a bearing has a sub-surface defect (early bearing wear), when a rolling element passes over the defect it bends the race slightly and then as the rolling element passes it restores back to it’s natural state.  This event causes a high frequency (1-50KHz) short duration stress wave.  This is what Peakvue detects
  • 6. How Does It Work?  A comparison can be made of the sampling to show how data is collected through both methods of data acquisition, normal and Peakvue™. FFT High Pass Filter Full Wave Rectify Digital Peak Impact Detection Vibration Signal
  • 7. How Does It Work?  The diagram below shows sampling of data using normal data collection. Stress wave- this is missed under normal conditions Instantaneous Samples
  • 8. Peakvue Samples How Does It Work?  The diagram below shows sampling of data using Peakvue™ data collection. Stress wave- this is missed under normal conditions
  • 9. How Does It Work?  Peakvue measures the highest amplitude found in a stress waves (Pk Value) and holds that data  The waveform data is then passed through a high pass filter to remove the unwanted, low frequencies – Imbalance, Misalignment, Looseness, resonance etc.  This just leaves us with the high frequency impacting data (Peak) above the machine noise level  The data is then brought back to fundamental frequency. (this allows analysis of the data to be done quicker and easier)
  • 10. Filters Types of filter available Filter Calculations Filter Guidelines
  • 11.  Selecting the wrong type of filter will result in poor quality data – To much noise filtered through (the spectrum becomes very noisy) – To much is filtered out (The stress wave is not allowed to pass through) Filters Options  There are two types of filter options in Peakvue, these are: – 1. Band Pass Filter – 2. High Pass Filter  Each of the filters are designed to remove unwanted data out of the signal at the appropriate levels  One of the key elements in acquiring meaningful peakvue data is the selection of ‘filters’
  • 12. Filter Options - ‘High Pass Filter’  High Pass Filters remove all frequencies from the data below the filter setting but allow the high frequency stress wave to pass through. All low frequencies are removed from the input signal Stress Wave data is allowed to pass through the filter High Pass Filter
  • 13. Filter Options - ‘Band Pass Filters’  Looks for stress waves within a parameter defined by the filter setting. Frequencies above and below this setting are removed from the data Data is filtered out of the signal Data is filtered out of the signal Data passes through filter
  • 14. Filter Selection  To select the correct filter we need to consider the highest operational defect frequency that we want to measure/detect. Then select the next available filter above that frequency  E.g. – Consider a typical motor / pump arrangement. We have: • 1 - 4 Pole A.C. Induction Motor • 2 - 3 Jaw Coupling • 3 - Centrifugal Pump – Typically the highest defect frequency to emit from this machine would be? • 1 - BPFI - Bearing Defect
  • 15. Filter Selection  4 Pole Motor A.C Induction fitted with bearings SKF 6313 – Defect Frequencies (Orders) • FTF - 0.384 • BSF - 2.037 • BPFO - 3.071 • BPFI - 4.929  Typically we would want to see the 10th Harmonic of the BPFI – Highest defect frequency: • (BPFI x 10) x Turning Speed (Hz) • (4.929 x 10) x 25 • 1232.3 Hz – We would then select the next available filter setting above the frequency
  • 16. Available filters  High Pass Filters – 500hz – 1000hz – 2000hz – 5000hz – 10000hz – 20000hz  Band Pass Filters – 20hz – 150hz – 50hz – 300hz – 100hz – 600hz – 500hz – 1khz Note: the meter will only allow you to select the next filter above the specified Fmax. From our previous calculation of 1232Hz, What filter setting would we select?
  • 17. Filter uses (Band Pass) - Guidelines  Band Pass Filters – 20hz – 150hz Felt problems on paper machines – 50hz – 300hz Certain structural resonance excitation, modulation of gearmesh in low speed machinery – 100hz – 600hz Gearmesh modulation in intermediate speed machinery. – 500hz – 1khz Gearmesh modulation Tip: use bandpass filters when the event of interest is the excitation of a structural resonance, or the modulation of known frequencies – such as gearmesh.
  • 18. Filter uses (Highpass) - guidelines  High Pass filters – 500hz Low speed machinery having <125hz. Bearing & gearing problems – 1000hz Intermediate speed machinery (<2000 rpm) with gear mesh <300hz – 2000hz Medium speed machinery (<4000rpm) with gear mesh ,600hz – 5000hz Machinery up to 9000rpm and gear mesh to 1500hz, Requires attention be paid to how the sensor is mounted as well as the sensors frequency response. – 10000hz High speed machinery with gear mesh up to 3000hz sensor must be permanently mounted with a frequency response of 3db in the 30kHz or higher range. – 20000hz High speed machinery with gearmesh up to 6000hz. Sensor must be high frequency and permanently mounted. Tip: Use highpass filters when the objective is to detect stress waves which are emitted by metal on metal impacting.
  • 19. Filter Selection - Question  Consider: – Motor running at a speed of 1000RPM – Driving a fan unit via pulley belts – Fan Speed is 1350RPM • Motor Bearings = SKF 3095 - BPFI 4.855 • Fan Bearings = SKF 6210 - BPFI 5.907  Calculate what Filter setting would be required for both the motor and the fan bearings? – Filters Available: • 500 Hz, 1000Hz, 2000Hz, 5000Hz, 10000Hz, 20000Hz. (High Pass) • 20-150Hz, 50-300Hz, 100-600Hz, 500-1KHz. (Band Pass)
  • 20. Filter Selection - Answers  Motor Speed = 1000CPM / 60 = 16.667Hz  Fan Speed = 1350CPM / 60 = 22.5Hz  Motor. – BPFI = 4.855 – Defect Frequency = (BPFI x 10) x Turning Speed (Hz) – Defect Frequency = (4.855 x 10) x 16.667 – Defect Frequency = 809.18 Hz  Filters Available: • 500 Hz, 1000Hz, 2000Hz, 5000Hz, 10000Hz, 20000Hz. (High Pass) • 20-150Hz, 50-300Hz, 100-600Hz, 500-1KHz. (Band Pass) 1000Hz
  • 21. Filter Selection - Answers  Motor Speed = 1000CPM / 60 = 16.667Hz  Fan Speed = 1350CPM / 60 = 22.5Hz  Fan – BPFI = 5.907 – Defect Frequency = (BPFI x 10) x Turning Speed (Hz) – Defect Frequency = (5.907 x 10) x 22.5 – Defect Frequency = 1329.07Hz  Filters Available: • 500 Hz, 1000Hz, 2000Hz, 5000Hz, 10000Hz, 20000Hz. (High Pass) • 20-150Hz, 50-300Hz, 100-600Hz, 500-1KHz. (Band Pass) 2000Hz
  • 22. Peakvue Data Spectrums and Waveforms Diagnostics Techniques
  • 23. Peakvue - Spectrum  Here is a typical Peakvue spectra plot.  This is typically a GOOD spectrum 1. Broad band energy - Filtered Noise 2. Units should be ‘acceleration’ (Very high frequency analysis) 3. Amplitude values are low. Severity of fault is not determined in the spectra
  • 24. Peakvue - Spectrum  This is a Peakvue spectrum where high frequency stress waves are being detected 1. Broad band energy - Filtered Noise 2. Units still in ‘acceleration’ (Very high frequency analysis) 3. Amplitude values are low. Remember severity of fault is not determined in the spectra Notice the Impacts passing through the filtered noise  This is indication of a fault developing
  • 25. Peakvue - Waveforms  Waveforms can be confused with spectrums, as the waveform is only plotting the peak value and does not show a full wave. A1 - Example 1 EX 1 -D3P Tail Roll Non D/S Peakv ue Label: Easy Analyz e W av eform 16-Mar-01 12:03:14 (PkVue- HP 500 Hz) PK = .0556 LOAD = 100.0 RPM = 80. RPS = 1.33 PK(+) = .5599 PK(-) = .0397 CRESTF= 14.25 0 3 6 9 12 -0.1 0 0.1 0.2 0.3 0.4 0.5 0.6 Rev olution Number Acceleration in G-s 1. Filtered Noise Level 2. Peak Value Impacts 3. No Peak Negative Value 4. Acceleration as default units
  • 26. Peakvue - Diagnostics  Diagnosing a Peakvue spectrum and waveform is not to dissimilar to that of conventional data.  However there are a few differences which can be a bit confusing at first, these are: – 1. Do not try to locate 1xTurning Speed, as this is low frequency data and will be filtered out. • Turning speed should be entered using the conventional spectral data. – 2. Multiple harmonics are often present within a spectrum due to the way peakvue samples the data. • These do not indicate ‘Looseness’ – 3. Spectral amplitudes are always low in amplitude but should not be used to judge severity. Use the spectrum to diagnose the fault. – 4. Waveforms indicate the severity of the problem.
  • 27. Peakvue - Diagnostics  Continued….. – 5. Ensure the same filter setting is used in both the spectrum and waveform. • Potential faults can be missed or overlooked if different filters are used. – 6. Cage Defects show up well in peakvue data and is normally an indication the bearing is under stress. – 7. All low frequency faults are removed from the data and will not be seen in a Peakvue spectrum and waveform • Imbalance, Misalignment, Looseness, Resonance - All Gone.
  • 28. Peakvue - Diagnostics 1.Spectral data indicating a defect at 5.463 Orders 2. Impacting also being detected at 0.6G-s 3. Very Slow RPM
  • 29. Peakvue - Diagnostics 4.Fault Frequencies Indicate a BPFI Defect
  • 30. Peakvue™ Amplitudes - Rolling Element Bearings  For machines running between speeds of 900 - 3600RPM recommended guidelines for setting initial warning levels in the Peakvue™ time - waveform are as follows: Alert Value Fault Value Inner Race 3.0g's 6.0g's Outer Race 6.0g's 12.0g's Rolling elements fault 4.5g's 9.0g's Cage frequencies If evident then the bearing is usually under stress.
  • 31. Peakvue™ Amplitudes - Rolling Element Bearings  For machines running at speeds <900RPM recommended guidelines for setting initial warning levels in the Peakvue™ time- waveform are as follows: 3 2.7 2.5 2.2 1.9 1.6 1.3 1.0 0.6 0.5 0.3 0.1 6 5.5 5.0 4.4 3.9 3.3 2.6 1.9 1.2 0.9 0.5 0.2 4.5 4.1 3.7 3.3 2.9 2.4 2.0 1.5 0.9 0.7 0.4 0.2 0 1 2 3 4 5 6 7 900 800 700 600 500 400 300 200 100 75 35 10 Inner race - Amplitude (g's) Outer race - Amplitude (g's) Rolling elements - Amplitude (g's) Levels for concern for machines running below 900 RPM RPM Acceleration g's
  • 33. Peakvue Vs Demodulation  What is Demodulation? – This is a technique which concentrates on stress wave analysis, but is not as effective.  How Does it Work? – Demodulation looks for the ringdown that follows an impact, and tries to measure how quickly it fades. In order to do this the ‘Time Waveform’ has to be manipulated in such away that the waveform data becomes useless Less than 1ms Initial Impact Ringdown
  • 34. Peakvue Vs Demodulation  What are the Differences? – Peakvue samples the data much quicker enabling it to catch the very short duration high frequency stress wave. It then holds that ‘Peak Value’ throughout its parameter. – Due to the Analogue filtering system used by Demodulation, results in a ‘delay in response’ and the stress wave impact is missed Demodulation registers Peak Impact Detection registers
  • 35. Peakvue Vs Demodulation High Pass Filter Full Wave Rectify Digital Peak Impact Detection FFT Peak Impact Detection High Pass Filter Low Pass Filter Full Wave Rectify Remove DC Bias A/D Converter FFT Standard Demodulation Enveloping Stage The Process!
  • 36. Peakvue Vs Demodulation  Case Study. – Equipment • A conveyor system consisting of six rolls is driven by a motor/gearbox unit (GMU). • The motor speed is 1500RPM reduced through the gearbox giving the roller speed to be 98.5RPM
  • 37. Peakvue Vs Demodulation  Data was collected on each bearing of the conveyor system • Due to the slow speeds Peakvue and Demodulation Filters were both set to 500Hz High Pass using 1600 Lines of Resolution Pv D - Example 1 Ex1 -R1P Roller Bearing Driv e End Label: Demodulated 500Hz High Pass Analyz e Spectrum 18-Dec-01 14:22:30 (Demod- HP 500 Hz ) PK = .0295 LOAD = 100.0 RPM = 97. RPS = 1.62 0 50 100 150 200 0 0.004 0.008 0.012 0.016 Frequency in Hz PK Acceleration in G-s Demodulation Spectra Pv D - Example 1 Ex1 -R1P Roller Bearing Driv e End Label: Peakv ue 500Hz High Pass Analyz e Spectrum 18-Dec-01 14:10:26 (PkVue- HP 500 Hz) PK = .1238 LOAD = 100.0 RPM = 99. RPS = 1.64 0 50 100 150 200 0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 Frequency in Hz PK Acceleration in G-s Peakvue Spectra PK Acceleration in G-s Frequency in Hz Pv D - Example 1 Ex1 -R1P Roller Bearing Driv e End (18-Dec-01) 0 50 100 150 200 0 0.01 0.02 0.03 0.04 0.05 Max Amp .0490 14:10: 26 18-Dec-01 14:10: 26 18-Dec-01 Direct Comparison Between the Two Peakvue Demodulation
  • 38. Peakvue Vs Demodulation Pv D - Example 1 Ex1 -R1P Roller Bearing Driv e End Rev olution Number Acceleration in G-s 0 1 2 3 4 5 6 7 Plot Span -0.2 1.0 18-Dec-01 14: 10 18-Dec-01 14: 22 Peakvue Waveform Demodulation Waveform
  • 39. Acquiring Peakvue Data Setting up the 2120A Creating a Peakvue AP Set
  • 40. Setting up the 2120A  Peakvue can be accessed from the ‘Analysis Expert’ options found among the command keys of the 2120A  There are two ways of acquiring peakvue data within the 2120A – Bearing/Gear Analysis - Peakvue • Preset to acquire Peakvue data based upon the AP set assigned to the machine – User Setup Option • Allows user interface to define their own parameters
  • 41. Setting up the 2120A  User Set-up Option – Define the Fmax you wish to go to. Remember the Fmax is going to define your filter setting. • 0 - 30 KCPM = 500Hz High Pass • 30 - 60 KCPM = 1000Hz High Pass • 60 - 120 KCPM = 2000Hz High Pass • 120v - 300 KCPM = 5000Hz High Pass  Lines of Resolution – These have to be good enough to capture the FTF of a bearing, which would equate to around 15 Revolutions of waveform data. • Number of Revs = Number of lines / Fmax(Orders) – E.g. 800 Lines over an Fmax of 60 Orders = 13.3 Revolutions (Inadequate) – 1600 Lines over an Fmax of 60 Orders = 26.6 Revolutions (OK)
  • 42. Setting up the 2120A  Averages – This has to be set to 1 Average to gain the ‘true peak’ value. • If you start averaging the data then a stress wave detected in the first average that is not there in the second will lose it’s true amplitude when averaged together.  By using the ‘Page Down’ Button we can toggle through the pages until we find our Peakvue Options (Page 4 of 4) – We turn Peakvue to ‘Yes’ – The Pre-filter can now be changed to our required HP Setting  Units – The default unit for peakvue is ‘Acceleration’. Remember we are trying to detect very high frequency events, well above conventional vibration data. Acceleration accentuates high frequencies. • Sensor units can be used if using an accelerometer, however CSI recommend a minimum mounting of a ‘Rare Earth Magnet’ for data collection
  • 43. Setting up the 2120  Data collection can now commence.  Check the data once collection has finished – Look for: • Impacts in both spectrum and waveform • Amplitude levels of the Waveform • quality of the data – If a problem is detected you may want to acquire more data with a different filter setting. – Remember to store the data once the reading has been taken  At least one Peakvue point should be applied to each critical machine to detect early bearing wear, gearwear or adverse metal to metal contact. – This will need building in the database and adding to the route
  • 45. 1. Open Database Management 2. Select Analysis Parameter Peakvue™ AP Set up I
  • 46. Peakvue™ AP Set up II 1. Complete the spectrum setup, specifying Fmax, LOR and averages (1). 2. Specify the number of parameters - 2
  • 47. Peakvue™ AP Set up III 1. Check, ‘Use Analog pre-processor 2. Select Peakvue, under the ‘Envelope Demodulator’ 3. Select the filter setting.
  • 48. Peakvue™ AP Set up IV 1. Uncheck, ‘obtain special time waveform?’ - As Default units will be acceleration 2. Discard all settings when this is unchecked
  • 49. Peakvue™ AP Set up V 1. Complete Analysis Parameter specifications, the most important parameter is the ‘peak to peak’ waveform parameter. 2. Ensure ‘unit type’ is acceleration
  • 52. Introduction  The above gearbox had been overhauled in the workshop and was on its final test run. A vibration signature was taken to confirm a small knock believed to be coming from the coupling, and prove the gearbox was OK.  The readings were taken using Peakvue and standard Vibration Technology on the corresponding points indicated in the diagram above. The following spectrum where obtained.
  • 53. Standard Data The standard spectrum below was taken from G5. Is there a Problem? G1 G3 G4 G5 G6 G7 G8 G9 G10 G11 G12 M1 M2
  • 54. The Peakvue reading shows distinct energy at 6.941 Hz and multiple harmonics of this which is the running speed of the third shaft. The bottom waveform shows clearly a substantial impacting of up to 12 G’s occurring each revolution. PeakVue™ Data
  • 55. The fault  The diagram below indicates the location of the suspected gear fault and was diagnosed as possibly a damaged tooth G1 G3 G4 G5 G6 G7 G8 G9 G10 G11 G12 M1 M2 Faulty Gear • When the gearbox was re-stripped and examined a cracked tooth on the gear identified was found.