Modified formulas for bucking length factor for rigid steel frame
structures
Abbas Moustafa1
, Magdy I. Salama2
1
(Associate Professor, Faculty of Engineering, Minia University, Egypt)
2
(Lecturer, Faculty of Engineering, Kafrelsheikh University, Egypt)
Abstract: In most current codes for design of steel structures, specifications for the design of compression
members utilize the effective length factor K. This parameter is employed to facilitate the design of frame
members by transforming an end-restrained compression member to an equivalent pinned-ended member. The
effective length factor is obtained either by solving the exact equations using a numerical iterative solution
which may be computationally expensive or by using a pair of alignment charts for the two-cases of braced and
sway frames. The accuracy of the solution using the second approach depends on the size of the charts and the
reader’s sharpness of vision. To eliminate these approximations, simple equations for determining the effective
length factor as a function of the rotational resistant at the column ends (GA, GB) are required. Similar
equations are available in the French design rules for steel structures since 1966, and are also included in the
1978 European recommendations. In this paper, modifications to the French design rules equations for effective
length factors are presented using multiple regressions for a tabulated exact values corresponding to different
practical values of the rotational resistance at column ends (GA, GB). The investigated equations are more
accurate than the current French rules equations recommended in steel codes of several countries.
Comparisons between the numerical results of the equations developed in this study and those obtained by
current equations with those obtained by exact solutions are given also in this paper.
Keywords: Effective length; steel column; multiple regressions; new formula; braced frame; sway frame
I. Introduction
The design of compression members such as steel columns and frames starts with the evaluation of the
elastic rotational resistance at both ends of the column (GA, GB), from which the effective length factor (K) is
determined. The exact mathematical equations for braced and sway rigid frames were given by Barakat and
Chen, 1990. These equations may be computationally expensive. An alternative approach to determine these
parameter is could be by using a pair of alignment charts for braced and sway frames, which was originally
developed by Julian and Lawrence, and presented in detail by Kavanagh (1962). These charts represent the
graphical solutions of the mathematically exact equations which are commonly used in most design codes (e.g.,
Manual of American institute of steel construction (LRFD and ASD), 1989 and the Egyptian code of practice
for steel constructions (LRFD and ASD), 2008. The accuracy of the alignment charts depends essentially on the
size of the chart and on the reader’s sharpness of vision. Also, having to read K-factors from an alignment chart
in the middle of a numerical computation, in spreadsheet for instance prevents full automation and can be a
source of errors.
Obviously, it would be convenient to have simple mathematical equations instead of the charts which
are commonly used in most codes of steel constructions. The American Institute does publish equations but their
lack of accuracy may be why they seem not to be used in steel design. Mathematical relations are available in
the French design rule for steel structures since 1966, and are also included in the 1978 European
recommendations (see e.g., Dumonteil, 1992).
In this paper, a modification to the French rule equations is developed to achieve more accurate closed
form expressions for the determination of the effective length factors as a function of the rotational resistance at
column ends. The presented equations are more practical since they can be easily coded within the confines of a
spreadsheet cell or within any mathematical software, such as Matlab, Maple or Mathematica.
II. Background For Exact And Approximate Equations
Consider a steel column AB elastically restrained at both ends. The rotational restraint at one end, A for
instance, is presented by restraint factor GA, expressing the relative stiffness of all the columns connected at A
to that of all the beams framing into A, given as:
 
 
/
/



C C
A
b b
I L
G
I L
(1)
Modified formulas for bucking length factor for rigid steel frame structures
DOI: 10.9790/1684-12326671 www.iosrjournals.org 67 | Page
A
B
A
B
Column under
study
Column under
study
In the European Recommendation 1978, two different factors A and B are used (rather than GA and
GB as in French Rules). The definition of  differs from that of G, given as:
( / )
( / ) ( / )
 


 
b b
b b C C
I L
I L I L
(2)
The mathematical expression relating G and  is thus given as follows:
1/ (1 )  G (3)
The Europeans tend to prefer using than using G since  =0 implies a hinged end and  =1 indicates
a fixed end. Obviously, the K-factor will be the same if the same elements are introduced in G and in both
expressions.
1. Braced Steel Frames
Braced steel frames are frame structures in which the side sway is effectively prevented as shown in
Figure (1-a), and, therefore, the K-factor less than or equal to 1.0. The side sway prevented alignment chart is
the graphic solution of the following mathematical equation:
2 / tan( / 2 )
( / ) 1 2 1
4 2 tan( / ) /
 

 
  
     
   
A B A B
G G G G K K
K
K K (4)
This equation is mathematically exact, in that certain physical assumptions are exactly translated in
mathematical terms. Whether these assumptions can be reasonably extended to a specific structure is a matter
for the designer to decide.
For the transcendental Eq. 4, which can only be solved by numerical methods. The French Rules
propose the following approximate solution:
3 1.4( ) 0.64
3 2.0( ) 1.28
  

  
A B A B
A B A B
G G G G
K
G G G G (5)
2. Sway Steel Frames
If a rigid frame depends solely on frame action to resist lateral forces, its side sway is permitted as shown in
Figure (1-b). In this case, the K-factor is never smaller than 1.0. The mathematical relation for the permitted
sway case is given as follows:
2
( / ) 36 /
6( ) tan( / )
 




A B
A B
G G K K
G G K (6)
Although Eq. (6) is simpler than Eq. (4), this equation, however, cannot be solved in a closed form. The French
Rules recommend the following approximate solution:
1.6 4.0( ) 7.5
7.5
  

 
A B A B
A B
G G G G
K
G G
(7)
(a) Braced frame (b) Sway frame
Fig. 1 Braced and sway frames
Modified formulas for bucking length factor for rigid steel frame structures
DOI: 10.9790/1684-12326671 www.iosrjournals.org 68 | Page
III. Theoretical Formulas
In this section, firstly, forms of the French rules equations are assumed as follows:
For braced frames,
𝐾=
aGAGB+ b GA+GB + c
𝑑GAGB+ e GA+GB + f
(8)
For sway frames,
𝐾=
𝑔𝐺 𝐴 𝐺 𝐵+ ℎ 𝐺 𝐴 +𝐺 𝐵 + 𝑖
𝐺 𝐴 +𝐺 𝐵+ 𝑗
𝑘
(9)
The parameters a, b,c …k are obtained by applying multiple regression analyses using the following
procedure:
- 300 pairs of different practical values of the rotational resistance at column ends (GA, GB) are selected and
the corresponding K values for sway and braced framework are used to fit the assumed equations, which
can be tested.
- The exact values of K factor were obtained by trial and error applying equations (Eqs. 4, 6) which are
solved numerically for both prevented and permitted sway end conditions. The resulting values are
approximated to the nearest higher integer numbers
- Using computer software, multiple regressions analyses based on the least-squares fitting method are
developed for each suggested formula to obtain the parameters which give the least standard error (less than
that corresponding to the current French Rules equations).
Subsequently, simple accurate mathematical expressions are investigated to determine the effective length factor
K for braced and sway end conditions as described below.
In case of braced frames; the equation for the effective length factor K is given by:
𝐾=
3GAGB+1.4 GA+GB +0.695
3GAGB+2 GA+GB +1.39
(10)
Where 0 100, 0 100   A B
G G
In case of sway frames; to get good results, two equations of effective length factor are investigated according to
the domain of the rotational resistance at column ends (GA, GB) as follows
0.6
0.97 3.3( ) 6.7
6.9
   
  
  
A B A B
A B
G G G G
K
G G
(11)
Where
0 10, 0 10   A BG G
and,
0.52
1.4 3.7( ) 6.15
6.45
   
  
  
A B A B
A B
G G G G
K
G G
(12)
Where
10 100 or 10 100  A BG G
IV. Accuracy Of Present Equations
The accuracy that we can readily measure is of course the mathematical accuracy, that is, the
comparison of the results given by the obtained formals to those obtained by solving the corresponding exact
equations. First, take a look to the accuracy of the most common alignment charts and the French Rules
equations.
The accuracy of the alignment charts depends essentially on the size of the charts and the reader’s
sharpness of vision. This accuracy may be about five percent in small charts. In the other hand, the French
Rules,1962indicate that Eq. (5), used for braced frames, has an accuracy of -0.50 percent to +1.50 percent while
Eq. (7) used for sway frames, is accurate within two percent.
Modified formulas for bucking length factor for rigid steel frame structures
DOI: 10.9790/1684-12326671 www.iosrjournals.org 69 | Page
The percentage of errors for all points considered in the present regressions analyses (about 300 point
for each case) indicate that the investigated equations in the present work is accurate within 1.0 percent for both
sway and braced frames.
V. Comparison Of The Results
Using a few sample points, tables (1, 2) show the comparison of the effective length factor Kobtained
by Equations [8 – 10] of the present work (P.W.), and that obtained by the current French Rules equations with
exact values for braced frames and sway frames respectively.
Table 1. Comparison of K-factors obtained by P. W. (year), French Rules(year)and exact results [side
sway is prevented]
GA GB
exact
P. W. % Diff.
French
% Diff.
Value Rule [7]
0.1 0.4 0.603 0.604 0.10 0.608 0.88
0.25 0.25 0.611 0.614 0.47 0.619 1.30
0.1 0.9 0.648 0.646 -0.28 0.651 0.42
0.25 0.75 0.672 0.672 0.05 0.677 0.79
0.5 0.5 0.686 0.687 0.17 0.692 0.92
0.1 1.9 0.683 0.682 -0.14 0.685 0.36
0.25 1.75 0.716 0.717 0.18 0.721 0.68
0.5 1.5 0.751 0.752 0.13 0.756 0.62
1 1 0.774 0.774 0.02 0.778 0.49
0.5 4.5 0.792 0.796 0.54 0.798 0.77
1 4 0.840 0.842 0.24 0.844 0.43
2.5 2.5 0.877 0.877 0.05 0.879 0.20
0.5 9.5 0.806 0.812 0.71 0.813 0.88
1 9 0.858 0.862 0.42 0.862 0.52
2.5 7.5 0.913 0.914 0.08 0.914 0.15
5 5 0.930 0.931 0.06 0.931 0.11
50 4 0.952 0.953 0.10 0.953 0.11
50 10 0.977 0.977 0.04 0.977 0.04
100 50 0.994 0.994 0.01 0.994 0.01
Table 2. Comparison of K-factors obtained by P. W., and French Rules with exact results [side sway is
permitted]
GA GB
exact
P. W. % Diff.
French
% Diff.
value Rule [7]
0.1 0.4 1.083 1.078 -0.45 1.093 0.96
0.25 0.25 1.083 1.080 -0.29 1.095 1.15
Modified formulas for bucking length factor for rigid steel frame structures
DOI: 10.9790/1684-12326671 www.iosrjournals.org 70 | Page
0.1 0.9 1.159 1.158 -0.09 1.170 0.99
0.25 0.75 1.162 1.164 0.21 1.178 1.40
0.5 0.5 1.164 1.169 0.40 1.183 1.65
0.1 1.9 1.286 1.283 -0.22 1.290 0.30
0.25 1.75 1.295 1.297 0.14 1.306 0.84
0.5 1.5 1.307 1.314 0.53 1.326 1.44
1 1 1.317 1.327 0.77 1.342 1.87
0.5 4.5 1.575 1.575 0.03 1.577 0.15
1 4 1.634 1.638 0.23 1.647 0.78
2.5 2.5 1.711 1.716 0.28 1.732 1.23
0.5 9.5 1.777 1.783 0.34 1.774 -0.15
1 9 1.874 1.881 0.36 1.881 0.36
2.5 7.5 2.092 2.093 0.06 2.104 0.59
5 5 2.228 2.222 -0.26 2.236 0.36
50 4 2.949 2.956 0.24 2.973 0.81
50 10 3.948 3.940 -0.21 3.939 -0.22
100 50 7.476 7.513 0.49 7.393 -1.12
It can be noticed that although the present equations are simple, it gave results very close to the exact
values and more accurate comparing with the solution by the currentFrench Rules equations. Then, the present
equations can be rather used by the designer engineers with sufficient confidence.
Also, as shown in Table (3), the standard error of the obtained formula Eq. (8) is about two-third of that
of French Rules Eq. (5) in case of braced frames while in the case of sway frames the standard error of Eqs. (9,
10) has less than one-half of that of French Rules Eq. (7).
Table 3. Comparison of standard error of the obtained equations and French Rules
Equations se
braced frames
French rule equation (5) 0.0048
modified equation (8) 0.0033
sway frames
French rule equation (7) 0.0212
modified equation (9) 0.0043
modified equation (10) 0.0137
VI. Conclusions
In this paper, simple closed form mathematical expressions (modified French rules equations) for the
determination of the effective length factor K for steel columns are derived using multiple regressions analyses
from the numerical results of the exact solution. The analysis is carried out for a wide range of the rotational
resistance at column ends GA, GB (from 0 to 100).
The obtained mathematical expressions are more practical in design purposes for the structural
engineer than the graphical charts since they provide a higher accuracy and can be easily coded in the Excel
spreadsheet or in mathematical software such as Matlab, Maple and Mathematica.
Modified formulas for bucking length factor for rigid steel frame structures
DOI: 10.9790/1684-12326671 www.iosrjournals.org 71 | Page
References
[1]. AISC (1986), Manual of Steel Construction, Load and Resistance Factor Design, American Institute of Steel Construction 1st Ed,
1986.
[2]. AISC (1989), Manual of Steel Construction, Allowable Stress Design, American Institute of Steel Construction 9th Ed, 1989.
[3]. European Convention for Constructional Steel work, European Recommendations for Steel Construction, 1978.
[4]. ECP (2008), Egyptian Code of Practice for Steel Construction (ECP), Load and Resistance Factor Design, 1st Ed, 2008
[5]. ECP (2008), Egyptian Code of Practice for Steel Construction (ECP) Allowable Stress Design, 1st Ed, 2008
[6]. Barakat, M., and Chen, W. F., Practical Analysis of Semi-Rigid Frames, AISC Engineering Journal, vol. 27 (2), pp. 54–68,
1990.aki, Y.
[7]. Pierre Dumonteil, Simple Equations for Effective Length Factor, AISC Engineering Journal, vol. 29 (3), pp. 111-115, 1992.
[8]. Thomas C. Kavanagh, Effective Length of Framed Columns, ASCE, vol. 127 (2), pp. 81-101, 1962.

More Related Content

What's hot

Concurrent lines -GEOMETRY
Concurrent lines -GEOMETRYConcurrent lines -GEOMETRY
Concurrent lines -GEOMETRYindianeducation
 
SEISMIC RESPONSE OF UNSYMMETRIC BUILDING WITH OPTIMALLY PLACED FRICTION DAMPERS
SEISMIC RESPONSE OF UNSYMMETRIC BUILDING WITH OPTIMALLY PLACED FRICTION DAMPERSSEISMIC RESPONSE OF UNSYMMETRIC BUILDING WITH OPTIMALLY PLACED FRICTION DAMPERS
SEISMIC RESPONSE OF UNSYMMETRIC BUILDING WITH OPTIMALLY PLACED FRICTION DAMPERSIAEME Publication
 
Deformation Analysis of a Triangular Mild Steel Plate Using CST as Finite Ele...
Deformation Analysis of a Triangular Mild Steel Plate Using CST as Finite Ele...Deformation Analysis of a Triangular Mild Steel Plate Using CST as Finite Ele...
Deformation Analysis of a Triangular Mild Steel Plate Using CST as Finite Ele...IJMER
 
Comparative Parametric Study of Seismic Behaviour of RC Framed Building With ...
Comparative Parametric Study of Seismic Behaviour of RC Framed Building With ...Comparative Parametric Study of Seismic Behaviour of RC Framed Building With ...
Comparative Parametric Study of Seismic Behaviour of RC Framed Building With ...IRJET Journal
 
Development of csharp based computer program for the design of single
Development of csharp based computer program for the design of singleDevelopment of csharp based computer program for the design of single
Development of csharp based computer program for the design of singleAlexander Decker
 
Problems-Structural Analysis_Najif Ismail
Problems-Structural Analysis_Najif IsmailProblems-Structural Analysis_Najif Ismail
Problems-Structural Analysis_Najif IsmailNậjḯf Ismail
 
Analysis of Parabolic Shell by Different Models Using Software SAP 2000
Analysis of Parabolic Shell by Different Models Using Software SAP 2000Analysis of Parabolic Shell by Different Models Using Software SAP 2000
Analysis of Parabolic Shell by Different Models Using Software SAP 2000ijtsrd
 
Reliability Analysis of an R.C Corner Footing Subjected to Bi-axial Bending
Reliability Analysis of an R.C Corner Footing Subjected to Bi-axial BendingReliability Analysis of an R.C Corner Footing Subjected to Bi-axial Bending
Reliability Analysis of an R.C Corner Footing Subjected to Bi-axial BendingIRJET Journal
 
Finite Element analysis of a hybrid RCS beam-column connection
Finite Element analysis of a hybrid RCS beam-column connectionFinite Element analysis of a hybrid RCS beam-column connection
Finite Element analysis of a hybrid RCS beam-column connectionQuang Huy Nguyen
 
Assessment of Soil Structure Interaction on RCC Underpass Bridge
Assessment of Soil Structure Interaction on RCC Underpass BridgeAssessment of Soil Structure Interaction on RCC Underpass Bridge
Assessment of Soil Structure Interaction on RCC Underpass BridgeIRJET Journal
 
Slope deflection method for structure analysis in civil engineering
Slope deflection method for structure analysis in civil engineeringSlope deflection method for structure analysis in civil engineering
Slope deflection method for structure analysis in civil engineeringNagma Modi
 
CopyofPartIIMME213TrussDesignProject
CopyofPartIIMME213TrussDesignProjectCopyofPartIIMME213TrussDesignProject
CopyofPartIIMME213TrussDesignProjectJacob Gonzalez
 
IRJET- Comparative Study of Performance of 60 Storey Steel Buildings with...
IRJET-  	  Comparative Study of Performance of 60 Storey Steel Buildings with...IRJET-  	  Comparative Study of Performance of 60 Storey Steel Buildings with...
IRJET- Comparative Study of Performance of 60 Storey Steel Buildings with...IRJET Journal
 

What's hot (20)

Bearing capacity of piles
Bearing capacity of pilesBearing capacity of piles
Bearing capacity of piles
 
Concurrent lines -GEOMETRY
Concurrent lines -GEOMETRYConcurrent lines -GEOMETRY
Concurrent lines -GEOMETRY
 
Design of a circular raft for a cylindrical core
Design of a circular raft for a cylindrical coreDesign of a circular raft for a cylindrical core
Design of a circular raft for a cylindrical core
 
I013137481
I013137481I013137481
I013137481
 
SEISMIC RESPONSE OF UNSYMMETRIC BUILDING WITH OPTIMALLY PLACED FRICTION DAMPERS
SEISMIC RESPONSE OF UNSYMMETRIC BUILDING WITH OPTIMALLY PLACED FRICTION DAMPERSSEISMIC RESPONSE OF UNSYMMETRIC BUILDING WITH OPTIMALLY PLACED FRICTION DAMPERS
SEISMIC RESPONSE OF UNSYMMETRIC BUILDING WITH OPTIMALLY PLACED FRICTION DAMPERS
 
Vol3no2 4
Vol3no2 4Vol3no2 4
Vol3no2 4
 
Prestress Scia Engineer
Prestress Scia EngineerPrestress Scia Engineer
Prestress Scia Engineer
 
Deformation Analysis of a Triangular Mild Steel Plate Using CST as Finite Ele...
Deformation Analysis of a Triangular Mild Steel Plate Using CST as Finite Ele...Deformation Analysis of a Triangular Mild Steel Plate Using CST as Finite Ele...
Deformation Analysis of a Triangular Mild Steel Plate Using CST as Finite Ele...
 
Comparative Parametric Study of Seismic Behaviour of RC Framed Building With ...
Comparative Parametric Study of Seismic Behaviour of RC Framed Building With ...Comparative Parametric Study of Seismic Behaviour of RC Framed Building With ...
Comparative Parametric Study of Seismic Behaviour of RC Framed Building With ...
 
3 d
3 d3 d
3 d
 
Development of csharp based computer program for the design of single
Development of csharp based computer program for the design of singleDevelopment of csharp based computer program for the design of single
Development of csharp based computer program for the design of single
 
Problems-Structural Analysis_Najif Ismail
Problems-Structural Analysis_Najif IsmailProblems-Structural Analysis_Najif Ismail
Problems-Structural Analysis_Najif Ismail
 
Analysis of Parabolic Shell by Different Models Using Software SAP 2000
Analysis of Parabolic Shell by Different Models Using Software SAP 2000Analysis of Parabolic Shell by Different Models Using Software SAP 2000
Analysis of Parabolic Shell by Different Models Using Software SAP 2000
 
Reliability Analysis of an R.C Corner Footing Subjected to Bi-axial Bending
Reliability Analysis of an R.C Corner Footing Subjected to Bi-axial BendingReliability Analysis of an R.C Corner Footing Subjected to Bi-axial Bending
Reliability Analysis of an R.C Corner Footing Subjected to Bi-axial Bending
 
Finite Element analysis of a hybrid RCS beam-column connection
Finite Element analysis of a hybrid RCS beam-column connectionFinite Element analysis of a hybrid RCS beam-column connection
Finite Element analysis of a hybrid RCS beam-column connection
 
A032010107
A032010107A032010107
A032010107
 
Assessment of Soil Structure Interaction on RCC Underpass Bridge
Assessment of Soil Structure Interaction on RCC Underpass BridgeAssessment of Soil Structure Interaction on RCC Underpass Bridge
Assessment of Soil Structure Interaction on RCC Underpass Bridge
 
Slope deflection method for structure analysis in civil engineering
Slope deflection method for structure analysis in civil engineeringSlope deflection method for structure analysis in civil engineering
Slope deflection method for structure analysis in civil engineering
 
CopyofPartIIMME213TrussDesignProject
CopyofPartIIMME213TrussDesignProjectCopyofPartIIMME213TrussDesignProject
CopyofPartIIMME213TrussDesignProject
 
IRJET- Comparative Study of Performance of 60 Storey Steel Buildings with...
IRJET-  	  Comparative Study of Performance of 60 Storey Steel Buildings with...IRJET-  	  Comparative Study of Performance of 60 Storey Steel Buildings with...
IRJET- Comparative Study of Performance of 60 Storey Steel Buildings with...
 

Viewers also liked

Ngủ ngon, ngủ đủ giấc mang lại lợi ích lớn lao
Ngủ ngon, ngủ đủ giấc mang lại lợi ích lớn laoNgủ ngon, ngủ đủ giấc mang lại lợi ích lớn lao
Ngủ ngon, ngủ đủ giấc mang lại lợi ích lớn laogeoffrey363
 
Brand Finance Global Forum 2016 brochure - final
Brand Finance Global Forum 2016 brochure - final Brand Finance Global Forum 2016 brochure - final
Brand Finance Global Forum 2016 brochure - final Anne Donoghue
 
GenChem000-WhatIsChemistry
GenChem000-WhatIsChemistryGenChem000-WhatIsChemistry
GenChem000-WhatIsChemistryhenry kang
 
Endla soostikku matk
Endla soostikku matkEndla soostikku matk
Endla soostikku matkKaspar Kask
 
vega rochat cv 2014
vega rochat cv 2014vega rochat cv 2014
vega rochat cv 2014vega rochat
 
Operations Semester Objectives
Operations Semester ObjectivesOperations Semester Objectives
Operations Semester ObjectivesMichael Warr
 
Image Storage, Indexing and Recognition
Image Storage, Indexing and RecognitionImage Storage, Indexing and Recognition
Image Storage, Indexing and RecognitionAdeel Riaz
 
vega rochat portfolio 2014
vega rochat portfolio 2014vega rochat portfolio 2014
vega rochat portfolio 2014vega rochat
 

Viewers also liked (20)

Ngủ ngon, ngủ đủ giấc mang lại lợi ích lớn lao
Ngủ ngon, ngủ đủ giấc mang lại lợi ích lớn laoNgủ ngon, ngủ đủ giấc mang lại lợi ích lớn lao
Ngủ ngon, ngủ đủ giấc mang lại lợi ích lớn lao
 
F017313341
F017313341F017313341
F017313341
 
G1303054353
G1303054353G1303054353
G1303054353
 
Brand Finance Global Forum 2016 brochure - final
Brand Finance Global Forum 2016 brochure - final Brand Finance Global Forum 2016 brochure - final
Brand Finance Global Forum 2016 brochure - final
 
GenChem000-WhatIsChemistry
GenChem000-WhatIsChemistryGenChem000-WhatIsChemistry
GenChem000-WhatIsChemistry
 
Endla soostikku matk
Endla soostikku matkEndla soostikku matk
Endla soostikku matk
 
vega rochat cv 2014
vega rochat cv 2014vega rochat cv 2014
vega rochat cv 2014
 
Operations Semester Objectives
Operations Semester ObjectivesOperations Semester Objectives
Operations Semester Objectives
 
Image Storage, Indexing and Recognition
Image Storage, Indexing and RecognitionImage Storage, Indexing and Recognition
Image Storage, Indexing and Recognition
 
A017410108
A017410108A017410108
A017410108
 
L010338894
L010338894L010338894
L010338894
 
curriculam vitae
curriculam vitaecurriculam vitae
curriculam vitae
 
Q13030194113
Q13030194113Q13030194113
Q13030194113
 
vega rochat portfolio 2014
vega rochat portfolio 2014vega rochat portfolio 2014
vega rochat portfolio 2014
 
I1303025763
I1303025763I1303025763
I1303025763
 
A012540108
A012540108A012540108
A012540108
 
E1303021829
E1303021829E1303021829
E1303021829
 
E010323842
E010323842E010323842
E010323842
 
B012140812
B012140812B012140812
B012140812
 
R01741124127
R01741124127R01741124127
R01741124127
 

Similar to J012326671

Analysis of different types of braces and chord connection in (CFST) k -joint...
Analysis of different types of braces and chord connection in (CFST) k -joint...Analysis of different types of braces and chord connection in (CFST) k -joint...
Analysis of different types of braces and chord connection in (CFST) k -joint...IRJET Journal
 
Structural Performance of Cold Formed Steel Quadruple Built-up Box Column
Structural Performance of Cold Formed Steel Quadruple Built-up Box ColumnStructural Performance of Cold Formed Steel Quadruple Built-up Box Column
Structural Performance of Cold Formed Steel Quadruple Built-up Box ColumnIRJET Journal
 
Seismic Response of Cellwise Braced Reinforced Concrete Frames
Seismic Response of Cellwise Braced Reinforced Concrete FramesSeismic Response of Cellwise Braced Reinforced Concrete Frames
Seismic Response of Cellwise Braced Reinforced Concrete FramesPralhad Kore
 
Seismic response of cellwise braced reinforced concrete frames
Seismic response of cellwise braced reinforced concrete framesSeismic response of cellwise braced reinforced concrete frames
Seismic response of cellwise braced reinforced concrete framesPralhad Kore
 
Defense_Thesis_Ramy_Gabr_06-22-2014_Final-with notes - Copy
Defense_Thesis_Ramy_Gabr_06-22-2014_Final-with notes - CopyDefense_Thesis_Ramy_Gabr_06-22-2014_Final-with notes - Copy
Defense_Thesis_Ramy_Gabr_06-22-2014_Final-with notes - CopyRamy Gabr, M.Sc, P.E.
 
Practical analysis procedures of steel portal frames having different connect...
Practical analysis procedures of steel portal frames having different connect...Practical analysis procedures of steel portal frames having different connect...
Practical analysis procedures of steel portal frames having different connect...Ali Msabawy
 
Seismic optimization of an I shaped shear link damper in EBF and CBF systems
Seismic optimization of an I shaped shear link damper in EBF and CBF systemsSeismic optimization of an I shaped shear link damper in EBF and CBF systems
Seismic optimization of an I shaped shear link damper in EBF and CBF systemsIRJET Journal
 
Multi objective Optimization of Reinforced Concrete Buildings
Multi objective Optimization of Reinforced Concrete BuildingsMulti objective Optimization of Reinforced Concrete Buildings
Multi objective Optimization of Reinforced Concrete Buildingscivejjour
 
Optimum participation of beams and columns in lateral resistance of steel mom...
Optimum participation of beams and columns in lateral resistance of steel mom...Optimum participation of beams and columns in lateral resistance of steel mom...
Optimum participation of beams and columns in lateral resistance of steel mom...Alexander Decker
 
Reliability Assessment of Cable-Stayed Bridges
Reliability Assessment of Cable-Stayed BridgesReliability Assessment of Cable-Stayed Bridges
Reliability Assessment of Cable-Stayed BridgesFranco Bontempi
 
Reliability Assessment of Cable-Stayed Bridges
Reliability Assessment of Cable-Stayed BridgesReliability Assessment of Cable-Stayed Bridges
Reliability Assessment of Cable-Stayed BridgesFranco Bontempi
 
Evaluation of Design Provisions for One-Way Solid Slabs in SBC-304
Evaluation of Design Provisions for One-Way Solid Slabs in SBC-304Evaluation of Design Provisions for One-Way Solid Slabs in SBC-304
Evaluation of Design Provisions for One-Way Solid Slabs in SBC-304IRJET Journal
 

Similar to J012326671 (20)

G012465564
G012465564G012465564
G012465564
 
J012427496
J012427496J012427496
J012427496
 
M10l24
M10l24M10l24
M10l24
 
M10l24
M10l24M10l24
M10l24
 
Cumbia theoryand userguide
Cumbia theoryand userguideCumbia theoryand userguide
Cumbia theoryand userguide
 
Analysis of different types of braces and chord connection in (CFST) k -joint...
Analysis of different types of braces and chord connection in (CFST) k -joint...Analysis of different types of braces and chord connection in (CFST) k -joint...
Analysis of different types of braces and chord connection in (CFST) k -joint...
 
Structural Performance of Cold Formed Steel Quadruple Built-up Box Column
Structural Performance of Cold Formed Steel Quadruple Built-up Box ColumnStructural Performance of Cold Formed Steel Quadruple Built-up Box Column
Structural Performance of Cold Formed Steel Quadruple Built-up Box Column
 
Seismic Response of Cellwise Braced Reinforced Concrete Frames
Seismic Response of Cellwise Braced Reinforced Concrete FramesSeismic Response of Cellwise Braced Reinforced Concrete Frames
Seismic Response of Cellwise Braced Reinforced Concrete Frames
 
Seismic response of cellwise braced reinforced concrete frames
Seismic response of cellwise braced reinforced concrete framesSeismic response of cellwise braced reinforced concrete frames
Seismic response of cellwise braced reinforced concrete frames
 
Defense_Thesis_Ramy_Gabr_06-22-2014_Final-with notes - Copy
Defense_Thesis_Ramy_Gabr_06-22-2014_Final-with notes - CopyDefense_Thesis_Ramy_Gabr_06-22-2014_Final-with notes - Copy
Defense_Thesis_Ramy_Gabr_06-22-2014_Final-with notes - Copy
 
2014 cac crs
2014 cac crs2014 cac crs
2014 cac crs
 
Ji2516561662
Ji2516561662Ji2516561662
Ji2516561662
 
Ji2516561662
Ji2516561662Ji2516561662
Ji2516561662
 
Practical analysis procedures of steel portal frames having different connect...
Practical analysis procedures of steel portal frames having different connect...Practical analysis procedures of steel portal frames having different connect...
Practical analysis procedures of steel portal frames having different connect...
 
Seismic optimization of an I shaped shear link damper in EBF and CBF systems
Seismic optimization of an I shaped shear link damper in EBF and CBF systemsSeismic optimization of an I shaped shear link damper in EBF and CBF systems
Seismic optimization of an I shaped shear link damper in EBF and CBF systems
 
Multi objective Optimization of Reinforced Concrete Buildings
Multi objective Optimization of Reinforced Concrete BuildingsMulti objective Optimization of Reinforced Concrete Buildings
Multi objective Optimization of Reinforced Concrete Buildings
 
Optimum participation of beams and columns in lateral resistance of steel mom...
Optimum participation of beams and columns in lateral resistance of steel mom...Optimum participation of beams and columns in lateral resistance of steel mom...
Optimum participation of beams and columns in lateral resistance of steel mom...
 
Reliability Assessment of Cable-Stayed Bridges
Reliability Assessment of Cable-Stayed BridgesReliability Assessment of Cable-Stayed Bridges
Reliability Assessment of Cable-Stayed Bridges
 
Reliability Assessment of Cable-Stayed Bridges
Reliability Assessment of Cable-Stayed BridgesReliability Assessment of Cable-Stayed Bridges
Reliability Assessment of Cable-Stayed Bridges
 
Evaluation of Design Provisions for One-Way Solid Slabs in SBC-304
Evaluation of Design Provisions for One-Way Solid Slabs in SBC-304Evaluation of Design Provisions for One-Way Solid Slabs in SBC-304
Evaluation of Design Provisions for One-Way Solid Slabs in SBC-304
 

More from IOSR Journals (20)

A011140104
A011140104A011140104
A011140104
 
M0111397100
M0111397100M0111397100
M0111397100
 
L011138596
L011138596L011138596
L011138596
 
K011138084
K011138084K011138084
K011138084
 
J011137479
J011137479J011137479
J011137479
 
I011136673
I011136673I011136673
I011136673
 
G011134454
G011134454G011134454
G011134454
 
H011135565
H011135565H011135565
H011135565
 
F011134043
F011134043F011134043
F011134043
 
E011133639
E011133639E011133639
E011133639
 
D011132635
D011132635D011132635
D011132635
 
C011131925
C011131925C011131925
C011131925
 
B011130918
B011130918B011130918
B011130918
 
A011130108
A011130108A011130108
A011130108
 
I011125160
I011125160I011125160
I011125160
 
H011124050
H011124050H011124050
H011124050
 
G011123539
G011123539G011123539
G011123539
 
F011123134
F011123134F011123134
F011123134
 
E011122530
E011122530E011122530
E011122530
 
D011121524
D011121524D011121524
D011121524
 

Recently uploaded

My Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationMy Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationRidwan Fadjar
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptxHampshireHUG
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)Gabriella Davis
 
Pigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food ManufacturingPigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food ManufacturingPigging Solutions
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking MenDelhi Call girls
 
Unblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesUnblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesSinan KOZAK
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Patryk Bandurski
 
Human Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsHuman Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsMark Billinghurst
 
SIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge GraphSIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge GraphNeo4j
 
The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxMalak Abu Hammad
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsMaria Levchenko
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationRadu Cotescu
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonetsnaman860154
 
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...shyamraj55
 
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersEnhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersThousandEyes
 
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024BookNet Canada
 
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...HostedbyConfluent
 
Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitecturePixlogix Infotech
 
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j
 
Maximizing Board Effectiveness 2024 Webinar.pptx
Maximizing Board Effectiveness 2024 Webinar.pptxMaximizing Board Effectiveness 2024 Webinar.pptx
Maximizing Board Effectiveness 2024 Webinar.pptxOnBoard
 

Recently uploaded (20)

My Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationMy Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 Presentation
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 
Pigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food ManufacturingPigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food Manufacturing
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men
 
Unblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesUnblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen Frames
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
 
Human Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsHuman Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR Systems
 
SIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge GraphSIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge Graph
 
The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptx
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed texts
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organization
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonets
 
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
 
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersEnhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
 
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
 
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
 
Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC Architecture
 
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
 
Maximizing Board Effectiveness 2024 Webinar.pptx
Maximizing Board Effectiveness 2024 Webinar.pptxMaximizing Board Effectiveness 2024 Webinar.pptx
Maximizing Board Effectiveness 2024 Webinar.pptx
 

J012326671

  • 1. IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-ISSN: 2278-1684,p-ISSN: 2320-334X, Volume 12, Issue 3 Ver. II (May - Jun. 2015), PP 66-71 www.iosrjournals.org DOI: 10.9790/1684-12326671 www.iosrjournals.org 66 | Page Modified formulas for bucking length factor for rigid steel frame structures Abbas Moustafa1 , Magdy I. Salama2 1 (Associate Professor, Faculty of Engineering, Minia University, Egypt) 2 (Lecturer, Faculty of Engineering, Kafrelsheikh University, Egypt) Abstract: In most current codes for design of steel structures, specifications for the design of compression members utilize the effective length factor K. This parameter is employed to facilitate the design of frame members by transforming an end-restrained compression member to an equivalent pinned-ended member. The effective length factor is obtained either by solving the exact equations using a numerical iterative solution which may be computationally expensive or by using a pair of alignment charts for the two-cases of braced and sway frames. The accuracy of the solution using the second approach depends on the size of the charts and the reader’s sharpness of vision. To eliminate these approximations, simple equations for determining the effective length factor as a function of the rotational resistant at the column ends (GA, GB) are required. Similar equations are available in the French design rules for steel structures since 1966, and are also included in the 1978 European recommendations. In this paper, modifications to the French design rules equations for effective length factors are presented using multiple regressions for a tabulated exact values corresponding to different practical values of the rotational resistance at column ends (GA, GB). The investigated equations are more accurate than the current French rules equations recommended in steel codes of several countries. Comparisons between the numerical results of the equations developed in this study and those obtained by current equations with those obtained by exact solutions are given also in this paper. Keywords: Effective length; steel column; multiple regressions; new formula; braced frame; sway frame I. Introduction The design of compression members such as steel columns and frames starts with the evaluation of the elastic rotational resistance at both ends of the column (GA, GB), from which the effective length factor (K) is determined. The exact mathematical equations for braced and sway rigid frames were given by Barakat and Chen, 1990. These equations may be computationally expensive. An alternative approach to determine these parameter is could be by using a pair of alignment charts for braced and sway frames, which was originally developed by Julian and Lawrence, and presented in detail by Kavanagh (1962). These charts represent the graphical solutions of the mathematically exact equations which are commonly used in most design codes (e.g., Manual of American institute of steel construction (LRFD and ASD), 1989 and the Egyptian code of practice for steel constructions (LRFD and ASD), 2008. The accuracy of the alignment charts depends essentially on the size of the chart and on the reader’s sharpness of vision. Also, having to read K-factors from an alignment chart in the middle of a numerical computation, in spreadsheet for instance prevents full automation and can be a source of errors. Obviously, it would be convenient to have simple mathematical equations instead of the charts which are commonly used in most codes of steel constructions. The American Institute does publish equations but their lack of accuracy may be why they seem not to be used in steel design. Mathematical relations are available in the French design rule for steel structures since 1966, and are also included in the 1978 European recommendations (see e.g., Dumonteil, 1992). In this paper, a modification to the French rule equations is developed to achieve more accurate closed form expressions for the determination of the effective length factors as a function of the rotational resistance at column ends. The presented equations are more practical since they can be easily coded within the confines of a spreadsheet cell or within any mathematical software, such as Matlab, Maple or Mathematica. II. Background For Exact And Approximate Equations Consider a steel column AB elastically restrained at both ends. The rotational restraint at one end, A for instance, is presented by restraint factor GA, expressing the relative stiffness of all the columns connected at A to that of all the beams framing into A, given as:     / /    C C A b b I L G I L (1)
  • 2. Modified formulas for bucking length factor for rigid steel frame structures DOI: 10.9790/1684-12326671 www.iosrjournals.org 67 | Page A B A B Column under study Column under study In the European Recommendation 1978, two different factors A and B are used (rather than GA and GB as in French Rules). The definition of  differs from that of G, given as: ( / ) ( / ) ( / )       b b b b C C I L I L I L (2) The mathematical expression relating G and  is thus given as follows: 1/ (1 )  G (3) The Europeans tend to prefer using than using G since  =0 implies a hinged end and  =1 indicates a fixed end. Obviously, the K-factor will be the same if the same elements are introduced in G and in both expressions. 1. Braced Steel Frames Braced steel frames are frame structures in which the side sway is effectively prevented as shown in Figure (1-a), and, therefore, the K-factor less than or equal to 1.0. The side sway prevented alignment chart is the graphic solution of the following mathematical equation: 2 / tan( / 2 ) ( / ) 1 2 1 4 2 tan( / ) /                   A B A B G G G G K K K K K (4) This equation is mathematically exact, in that certain physical assumptions are exactly translated in mathematical terms. Whether these assumptions can be reasonably extended to a specific structure is a matter for the designer to decide. For the transcendental Eq. 4, which can only be solved by numerical methods. The French Rules propose the following approximate solution: 3 1.4( ) 0.64 3 2.0( ) 1.28        A B A B A B A B G G G G K G G G G (5) 2. Sway Steel Frames If a rigid frame depends solely on frame action to resist lateral forces, its side sway is permitted as shown in Figure (1-b). In this case, the K-factor is never smaller than 1.0. The mathematical relation for the permitted sway case is given as follows: 2 ( / ) 36 / 6( ) tan( / )       A B A B G G K K G G K (6) Although Eq. (6) is simpler than Eq. (4), this equation, however, cannot be solved in a closed form. The French Rules recommend the following approximate solution: 1.6 4.0( ) 7.5 7.5       A B A B A B G G G G K G G (7) (a) Braced frame (b) Sway frame Fig. 1 Braced and sway frames
  • 3. Modified formulas for bucking length factor for rigid steel frame structures DOI: 10.9790/1684-12326671 www.iosrjournals.org 68 | Page III. Theoretical Formulas In this section, firstly, forms of the French rules equations are assumed as follows: For braced frames, 𝐾= aGAGB+ b GA+GB + c 𝑑GAGB+ e GA+GB + f (8) For sway frames, 𝐾= 𝑔𝐺 𝐴 𝐺 𝐵+ ℎ 𝐺 𝐴 +𝐺 𝐵 + 𝑖 𝐺 𝐴 +𝐺 𝐵+ 𝑗 𝑘 (9) The parameters a, b,c …k are obtained by applying multiple regression analyses using the following procedure: - 300 pairs of different practical values of the rotational resistance at column ends (GA, GB) are selected and the corresponding K values for sway and braced framework are used to fit the assumed equations, which can be tested. - The exact values of K factor were obtained by trial and error applying equations (Eqs. 4, 6) which are solved numerically for both prevented and permitted sway end conditions. The resulting values are approximated to the nearest higher integer numbers - Using computer software, multiple regressions analyses based on the least-squares fitting method are developed for each suggested formula to obtain the parameters which give the least standard error (less than that corresponding to the current French Rules equations). Subsequently, simple accurate mathematical expressions are investigated to determine the effective length factor K for braced and sway end conditions as described below. In case of braced frames; the equation for the effective length factor K is given by: 𝐾= 3GAGB+1.4 GA+GB +0.695 3GAGB+2 GA+GB +1.39 (10) Where 0 100, 0 100   A B G G In case of sway frames; to get good results, two equations of effective length factor are investigated according to the domain of the rotational resistance at column ends (GA, GB) as follows 0.6 0.97 3.3( ) 6.7 6.9           A B A B A B G G G G K G G (11) Where 0 10, 0 10   A BG G and, 0.52 1.4 3.7( ) 6.15 6.45           A B A B A B G G G G K G G (12) Where 10 100 or 10 100  A BG G IV. Accuracy Of Present Equations The accuracy that we can readily measure is of course the mathematical accuracy, that is, the comparison of the results given by the obtained formals to those obtained by solving the corresponding exact equations. First, take a look to the accuracy of the most common alignment charts and the French Rules equations. The accuracy of the alignment charts depends essentially on the size of the charts and the reader’s sharpness of vision. This accuracy may be about five percent in small charts. In the other hand, the French Rules,1962indicate that Eq. (5), used for braced frames, has an accuracy of -0.50 percent to +1.50 percent while Eq. (7) used for sway frames, is accurate within two percent.
  • 4. Modified formulas for bucking length factor for rigid steel frame structures DOI: 10.9790/1684-12326671 www.iosrjournals.org 69 | Page The percentage of errors for all points considered in the present regressions analyses (about 300 point for each case) indicate that the investigated equations in the present work is accurate within 1.0 percent for both sway and braced frames. V. Comparison Of The Results Using a few sample points, tables (1, 2) show the comparison of the effective length factor Kobtained by Equations [8 – 10] of the present work (P.W.), and that obtained by the current French Rules equations with exact values for braced frames and sway frames respectively. Table 1. Comparison of K-factors obtained by P. W. (year), French Rules(year)and exact results [side sway is prevented] GA GB exact P. W. % Diff. French % Diff. Value Rule [7] 0.1 0.4 0.603 0.604 0.10 0.608 0.88 0.25 0.25 0.611 0.614 0.47 0.619 1.30 0.1 0.9 0.648 0.646 -0.28 0.651 0.42 0.25 0.75 0.672 0.672 0.05 0.677 0.79 0.5 0.5 0.686 0.687 0.17 0.692 0.92 0.1 1.9 0.683 0.682 -0.14 0.685 0.36 0.25 1.75 0.716 0.717 0.18 0.721 0.68 0.5 1.5 0.751 0.752 0.13 0.756 0.62 1 1 0.774 0.774 0.02 0.778 0.49 0.5 4.5 0.792 0.796 0.54 0.798 0.77 1 4 0.840 0.842 0.24 0.844 0.43 2.5 2.5 0.877 0.877 0.05 0.879 0.20 0.5 9.5 0.806 0.812 0.71 0.813 0.88 1 9 0.858 0.862 0.42 0.862 0.52 2.5 7.5 0.913 0.914 0.08 0.914 0.15 5 5 0.930 0.931 0.06 0.931 0.11 50 4 0.952 0.953 0.10 0.953 0.11 50 10 0.977 0.977 0.04 0.977 0.04 100 50 0.994 0.994 0.01 0.994 0.01 Table 2. Comparison of K-factors obtained by P. W., and French Rules with exact results [side sway is permitted] GA GB exact P. W. % Diff. French % Diff. value Rule [7] 0.1 0.4 1.083 1.078 -0.45 1.093 0.96 0.25 0.25 1.083 1.080 -0.29 1.095 1.15
  • 5. Modified formulas for bucking length factor for rigid steel frame structures DOI: 10.9790/1684-12326671 www.iosrjournals.org 70 | Page 0.1 0.9 1.159 1.158 -0.09 1.170 0.99 0.25 0.75 1.162 1.164 0.21 1.178 1.40 0.5 0.5 1.164 1.169 0.40 1.183 1.65 0.1 1.9 1.286 1.283 -0.22 1.290 0.30 0.25 1.75 1.295 1.297 0.14 1.306 0.84 0.5 1.5 1.307 1.314 0.53 1.326 1.44 1 1 1.317 1.327 0.77 1.342 1.87 0.5 4.5 1.575 1.575 0.03 1.577 0.15 1 4 1.634 1.638 0.23 1.647 0.78 2.5 2.5 1.711 1.716 0.28 1.732 1.23 0.5 9.5 1.777 1.783 0.34 1.774 -0.15 1 9 1.874 1.881 0.36 1.881 0.36 2.5 7.5 2.092 2.093 0.06 2.104 0.59 5 5 2.228 2.222 -0.26 2.236 0.36 50 4 2.949 2.956 0.24 2.973 0.81 50 10 3.948 3.940 -0.21 3.939 -0.22 100 50 7.476 7.513 0.49 7.393 -1.12 It can be noticed that although the present equations are simple, it gave results very close to the exact values and more accurate comparing with the solution by the currentFrench Rules equations. Then, the present equations can be rather used by the designer engineers with sufficient confidence. Also, as shown in Table (3), the standard error of the obtained formula Eq. (8) is about two-third of that of French Rules Eq. (5) in case of braced frames while in the case of sway frames the standard error of Eqs. (9, 10) has less than one-half of that of French Rules Eq. (7). Table 3. Comparison of standard error of the obtained equations and French Rules Equations se braced frames French rule equation (5) 0.0048 modified equation (8) 0.0033 sway frames French rule equation (7) 0.0212 modified equation (9) 0.0043 modified equation (10) 0.0137 VI. Conclusions In this paper, simple closed form mathematical expressions (modified French rules equations) for the determination of the effective length factor K for steel columns are derived using multiple regressions analyses from the numerical results of the exact solution. The analysis is carried out for a wide range of the rotational resistance at column ends GA, GB (from 0 to 100). The obtained mathematical expressions are more practical in design purposes for the structural engineer than the graphical charts since they provide a higher accuracy and can be easily coded in the Excel spreadsheet or in mathematical software such as Matlab, Maple and Mathematica.
  • 6. Modified formulas for bucking length factor for rigid steel frame structures DOI: 10.9790/1684-12326671 www.iosrjournals.org 71 | Page References [1]. AISC (1986), Manual of Steel Construction, Load and Resistance Factor Design, American Institute of Steel Construction 1st Ed, 1986. [2]. AISC (1989), Manual of Steel Construction, Allowable Stress Design, American Institute of Steel Construction 9th Ed, 1989. [3]. European Convention for Constructional Steel work, European Recommendations for Steel Construction, 1978. [4]. ECP (2008), Egyptian Code of Practice for Steel Construction (ECP), Load and Resistance Factor Design, 1st Ed, 2008 [5]. ECP (2008), Egyptian Code of Practice for Steel Construction (ECP) Allowable Stress Design, 1st Ed, 2008 [6]. Barakat, M., and Chen, W. F., Practical Analysis of Semi-Rigid Frames, AISC Engineering Journal, vol. 27 (2), pp. 54–68, 1990.aki, Y. [7]. Pierre Dumonteil, Simple Equations for Effective Length Factor, AISC Engineering Journal, vol. 29 (3), pp. 111-115, 1992. [8]. Thomas C. Kavanagh, Effective Length of Framed Columns, ASCE, vol. 127 (2), pp. 81-101, 1962.