Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for
Vector Controlled Induction Motor Drives
Varsharani J. More1
, N. G. Kulkarni2
, Dr. R. M. Nagarale3
1(PG student, M.B.E. Societyโ€™s college of engineering, Ambajogai, Maharashtra, India)
2,3 (PG Department, M.B.E. Societyโ€™s College of engineering, Ambajogai, Maharashtra, India)
Abstract : This paper presents a simple method for isolation of open circuit fault in pulse width modulated
voltage source inverters (PWM VSIs) feeding vector controlled induction motor drives. The VSI operation
process is repeated over the period of time. This repetitive operation is divided into six operating statges by
certain rules depending upon the phase angle of one phase current. At each stage, only three power switches
make vital influece and the other three perform negligible influence on the operation of VSI. The open circuit
fault affects the operation and introduces the repetitive distortions in current waveforms. These distortions are
observed at faulty stage and gets disappeared at healthy stage. Here, fuzzy logic controller is used for isolation
of fault which shows itโ€™s effectiveness in simulations and results.
Keywords โ€“ Fault detection, fault isolation, fuzzy logic controller, open circuit fault. PWM VSI.
I. Introduction
The electric drive systems are used widely in the most of industrial manufacturing processes. Many
times these drive systems are exposed to overloading or different environmental conditions, which result into
aging process, to faults concern with induction motor or the inverter. These faults can be the reason for
unpredicted downtime or damages to human life. Hence demand for maintainability and reliability is increasing
largely.
Fig.1. General configuration of an induction motor drive system
Generally, a motor drive system includes a microcontroller unit (MCU) for implementation of the
control algorithms, a power electronic device such as pulse width modulated voltage source inverter (PWM
VSI), and an induction motor as shown in Fig.1. Within this drive system, faults can occur in the inverter, dc
bus, or in the motor itself. A voltage-source inverter is the most commonly used inverter topology in these
systems and also in power quality applications. By considering their complexity, these power converters are
found very susceptible in suffering critical failures. The fact is that about 38% of the failures in variable speed
ac drives in industry are occurred in power electronics [1]. Recently, a survey of reliability in power electronic
converters shows that semiconductor power device is the most fragile component, which is followed by
capacitors and gate drives [2].
Now-a-days, the power converters designed for industrial use can be equipped with some diagnostic
units to protect against disturbances and execute a shutdown in case of severe faults in order to avoid greater
damages. It has become a standard feature for the inverters to protect against power transistor over current or
short circuit by monitoring the transistor collectorโ€“emitter voltage but the open-circuit failures often cause slow
Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Inductionโ€ฆ
DOI: 10.9790/1676-10620715 www.iosrjournals.org 8 | Page
response. This type of fault may result the disconnection of the semiconductor due to lifting of bonding wires
caused by thermic cycling or due to a problem in the gate control signal [3]. This kind of failure does not
necessarily cause the system shutdown and can remain undetected for an extended period of time [4]. Since, it
degrades the performance of the system by causing the operating topology imbalance, raising the current
pressure of healthy transistors and thus a secondary fault may occur in the converter or in the remaining drive
components which may result the total system shutdown and higher repairing costs, or even personal injury. So
this paper introduces a simple and effective approach for detection of the open-circuit faults in inverter switches
and isolation by using fuzzy logic controller.
Several papers and research works have been published and developed in the literature on the open-
circuit fault diagnosis in the motor drive systems. Initially, a fault tolerant system was proposed for a brushless
DC motor [4]. Further, the methods based on voltage, such as the error voltage method which compares the
actual voltage with voltage command and lower switch voltage method [5], where the measurement of the
voltages is used, show a fast diagnosis performance and thus reduce the time between the fault occurrence and
diagnosis. But its major drawback is to increase system cost as it requires extra hardware equipments such as
voltage sensors and electric circuits. The centroid determination method presented in [6] detects and identifies
the faults in an inverter-fed induction motor from the centroid of the three-phase currents transformed from a โˆ’
b โ€“ c to ฮฑ โˆ’ ฮฒ plane. In [7], two methods based on the analysis of these current vectors are proposed by the
authors. The first one is known as slope method which uses the current vector trajectory in the Concordia plane
to detect and localize faults on a PWM inverter. The second is called instantaneous frequency method that
allows to detect an inverter fault, but not to identify the faulty switch. Moreover, the Park current vector method
was introduced in [8], [9] by monitoring the average motor supply current trajectory to diagnose the faults in
variable speed ac drives. The main drawback of all these earlier mentioned methods is the susceptibility to the
load torque. In [9], the authors suggested the normalized direct component (DC) current method. To make the
scheme independent from the load, the mean values of the three-phase currents are divided by the absolute value
of its own first harmonic coefficients and by comparing with a threshold, faults are diagnosed. These suggested
current-based methods have shown active performances in current open-loop control scheme such as scalar (V
/f) control, but are not seen quite effective in current closed-loop control scheme such as vector control [10].
Fig.2. Ordinary indirect vector control system of an induction motor.
In this paper a simple method for detection and isolation of open-circuit faults of VSI feeding a vector-
controlled induction motor drive by using fuzzy logic controller is presented. The principle of vector control
gives a deep analysis and thus the relative features such as change in current distortions in faulty condition are
obtained to detect and identify the faults. In this proposed scheme waveforms for three different conditions are
observed: 1) Open loop response at normal stage, 2) open loop response with fault and 3) closed loop response
with fault using controller. By introducing the fault in the circuit and setting required reference speed, the
simulation results are obtained. These results are introduced with a distortion in current waveforms due to fault.
In order to overcome this faulty stage, a fuzzy logic controller is used. The proposed fault isolation is configured
without extra hardware equipment and excessive computational effort and thus allows to be embedded into an
existing vector-controlled induction motor drive system. To test and validate the proposed method, open-circuit
faults are introduced in the VSI for a vector-controlled induction motor drive. Simulation results show the
validity of the proposed approach.
II. Open-Circuit Fault Analysis In The VSI
When a transistor of an inverter does not work or turn on, the phase current of a machine are no longer
sinusoidal. In a majority of fault detection methods, used for induction motor drives, three phase currents are
Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Inductionโ€ฆ
DOI: 10.9790/1676-10620715 www.iosrjournals.org 9 | Page
inputs for detection of faults. The ultimate purpose of vector control is to drive the induction motor as a shunt-
wound dc motor which means to control the field excitation and the torque-generating current separately. Fig.2
shows an ordinary indirect vector control system of an induction motor drive without consideration of flux
weakening. Here, the three phase currents are first transformed by using coordinate transformation into two
synchronously rotating Cartesian vector components id and iq which are controlled independently to control the
rotor flux and torque respectively. It can be expressed by the set of equations with dโ€“q frame with rotor-flux
orientation.
๐‘‡๐‘’ =
๐‘› ๐‘ ๐ฟ ๐‘š
๐ฟ๐‘Ÿ
๏™ ๐‘Ÿ ๐‘– ๐‘ž (1)
๏™ ๐‘Ÿ =
๐ฟ ๐‘š
๐ฟ ๐‘Ÿ
๐‘… ๐‘Ÿ ๐‘
+1
๐‘– ๐‘‘ (2)
where, id and iq denote d- and q-axis rotor currents, ฯˆr is the rotor flux in rotor reference frame, Te stands for
the electromagnetic torque, np is the number of pole pairs, Lm and Lr are the magnetizing inductance and rotor
self-inductance, respectively, Rr is the rotor resistance, and p is the differential operator d/dt.
The currents id and iq in the dโˆ’q frame can be derived from the currents in the ฮฑโˆ’ฮฒ frame by Park
transformation which is defined as
๐‘– ๐‘‘ = ๐‘– ๐›ผ ๐‘๐‘œ๐‘  ๐œƒ + ๐‘– ๐›ฝ ๐‘ ๐‘–๐‘› ๐œƒ (3)
๐‘– ๐‘ž = โˆ’๐‘– ๐›ผ ๐‘ ๐‘–๐‘› ๐œƒ + ๐‘– ๐›ฝ ๐‘๐‘œ๐‘  ๐œƒ (4)
where ฮธ is the rotor flux angle or transform angle, generated from the speed signal and slip signal and the
currents iฮฑ and iฮฒ in stationary frame are transformed by Clarke transformation defined as
๐‘– ๐›ผ =
2
3
๐‘– ๐‘Ž โˆ’
1
2
๐‘– ๐‘ โˆ’
1
2
๐‘– ๐‘ (5)
๐‘– ๐›ฝ =
2
3
3
2
๐‘– ๐‘ โˆ’
3
2
๐‘– ๐‘ (6)
where ia , ib and ic are the motor phase currents.
The vector control is based on projections which transform a three-phase time and speed dependent
system into a two-coordinate (d- and q-coordinate) time invariant system and lead to a structure similar to a dc
machine control. The vector control machine needs two variables as input references: the torque component
(i*
q ) and the flux component (i*
d). The vector control structure handles the instantaneous electrical quantities, as
it is based on projections. This makes the control accurate in every working operation (steady states and
transient) and independent of the limited bandwidth mathematical model. Without consideration of flux
weakening, the amplitude of the rotor flux (ฯˆr) is maintained at a fixed value and thus there is a linear
relationship between torque and torque component (iq). Thereby, the torque can be control by controlling the
torque component of stator current vector. With regard to the current, the complex stator current vector is
defined by
๐‘– ๐‘  = ๐‘– ๐‘Ž + ๏ง๐‘– ๐‘ + ๏ง2
๐‘– ๐‘ = ๐‘– ๐‘‘ + ๐‘– ๐‘ž = ๐‘– ๐›ผ + ๐‘– ๐›ฝ (7)
where ฮณ = ej2ฯ€/3
and ฮณ = ej4ฯ€/3
represent the spatial operator. Considering the d-axis aligned with the rotor flux,
Fig. 3 shows the relationship between the ฮฑ โˆ’ ฮฒ reference frame and the d โˆ’ q frame.
Fig.3. Current vector in the d โˆ’ q frame and its relationship with the ฮฑ โ€“ ฮฒ frame.
Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Inductionโ€ฆ
DOI: 10.9790/1676-10620715 www.iosrjournals.org 10 | Page
Fig.4. Three-phase currents distribution in the power switches
III. Design Of Proposed FLC
The main reason for choosing a fuzzy approach is the very nature of the changes in the attributes. It is
nonlinear, and in addition, it would be unreasonable to expect that each time the same level of a particular fault
arises, the attributes would measure exactly the same values. The boundaries between two levels of a certain
fault are not sharply defined, and therefore the use of a fuzzy logic control is appropriate. Membership functions
and the degree of membership, rather than yes or no membership, give the opportunity, using previously
acquired knowledge about the system attributes.
Fig.5. Structure of Proposed FLC
The input membership functions are usually a symmetric triangle with equal distribution over the
universe of discourse. The formulation of membership functions of output variables show more variety
frequently.
In FLC design, one should identify the main control variables and determine the sets that describe the
values of each linguistic variable. The specific structure of the FLC is shown in Fig.5. The input variables of the
FLC are the reference speed and the change in the speed. The triangular membership functions are used for the
FLC for easier computation. The Mamdani fuzzy inference method is used for the proposed FLC. In this
controller, membership functions (N, Z, P) assigned with linguistic variables are used to fuzzify physical
quantities. For inputs e(k) and e0(k) we have (e.n, e.z, e.p) and (e0.n, e0.z, e0.p). For the output u(k), we have
(o.n, o.z, o.p). The fuzzified inputs are inferred to a fuzzy rule base, which is used to characterize the
relationship between fuzzy inputs and fuzzy outputs. In this study, the fuzzy rule base of the fuzzy logic
controller is fixed. It consists of the following nine fuzzy rules:
1. If e(k)=N and e0(k)=P then u(k)=Z.
2. If e(k)=Z and e0(k)=P then u(k)=P.
3. If e(k)=P and e0(k)=P then u(k)=P.
4. If e(k)=N and e0(k)=Z then u(k)=N.
5. If e(k)=N and e0(k)=N then u(k)=N.
6. If e(k)=P and e0(k)=Z then u(k)=P.
7. If e(k)=Z and e0(k)=N then u(k)=N.
The response of each fuzzy rule is weighted according to the degree of membership of its input
conditions. The inference engine provides a set of control actions according to fuzzified inputs. The commonly
used inference engine is the MAX-MIN method and the centroid method is used for the defuzzification process.
Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Inductionโ€ฆ
DOI: 10.9790/1676-10620715 www.iosrjournals.org 11 | Page
IV. Results And Simulation
Simulation was applied on MATLAB/Simulink to the proposed fuzzy controller for the PWM VSI. The
PI controller is selected for comparison because of its severe use in industry applications. The motor used in the
simulation was a 5.5 kW squirrel cage motor with 400 V rated voltage, 12.5 A rated current and 1430 r/min
rated speed. The PWM VSI was running with a switching frequency of 20 kHz.
4.1 Open Loop Response At Normal Condition:
At normal and healthy condition i.e. when there is no fault in the inverter circuit, the current and
voltage remain unchanged for it is the flux component of the stator current. The speed and torque are also
continuous with time as motor is running smoothly. These all simulation results are shown below. It changes
only when faults occur. So the current distortion is used to detect the occurrence of faults. When a fault occurs,
both the current and voltage change abnormally and show repetitive waveforms. They distort at faulty stages
where the faulty power switches make a vital influence and return to normal at healthy stages where the faulty
power switches make a negligible influence.
(1-a)
(1-b)
(1-c)
Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Inductionโ€ฆ
DOI: 10.9790/1676-10620715 www.iosrjournals.org 12 | Page
(1-d)
Fig.6. Simulation results in normal condition without fault: (1-a) Motor speed; (1-b) Output current;(1-c) Output
voltage; (1-d) Load torque.
4.2 Open Loop Response At Faulty Condition:
When the fault occurs in the VSI circuit, step change is introduced in switching pulse and the other
parameters get disturbed wiz. Speed of the motor decreases and continues at low speed till the fault isnโ€™t
isolated. In case of current and voltage the waveforms gets distorted means the waveforms shows repetitive
distortions until the fault isolation. The torque also changes at the instant of fault occurrence then continues to
normal.
(2-a)
(2-b)
Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Inductionโ€ฆ
DOI: 10.9790/1676-10620715 www.iosrjournals.org 13 | Page
(2-c)
(2-d)
Fig.7. Simulation results in normal condition without fault: (2-a) Motor speed; (2-b) Output current; (2-c)
Output voltage; (2-d) Load torque.
4.3 Closed Loop Response With Fuzzy Logic Controller:
In order to overcome above results due to fault a fuzzy logic controller is used. With the help of this
controller fault is isolated and the motor runs in normal condition. This is observed in below simulational
results. As the fuzzy logic controller is more improved than a conventional PI controller, it gives the accurate
and results.
(3-a)
Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Inductionโ€ฆ
DOI: 10.9790/1676-10620715 www.iosrjournals.org 14 | Page
(3-b)
(3-c)
`
(3-d)
Fig.8. Simulation results in normal condition without fault: (3-a) Motor speed; (3-b) Output current; (3-c)
Output voltage; (3-d) Load torque.
V. Conclusion
This paper has presented Fault Isolation in PWM Voltage-Source Inverters for Vector controlled
Induction Motor Drives using Fuzzy logic controller. Simulation results are obtained showing a good agreement
with the theoretical analysis. This method uses just as inputs the three-phase currents which are already
available for the main control system, avoiding the use of extra sensors and the subsequent increase of the
system complexity and costs. Comparing with previously published methods, the original method relies on the
stage conversion. An open-circuit fault of power switches in the VSI changes the corresponding phase currents
and introduces the periodic current distortions. When the fault occurs, the distortions are estimated. In order to
overcome these estimated distortions, the fuzzy logic controller is used in the circuit. This controller shows the
Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Inductionโ€ฆ
DOI: 10.9790/1676-10620715 www.iosrjournals.org 15 | Page
more accuracy than the conventional PI controller. Moreover, this method can be embedded into the existing
vector-controlled induction motor drive software as a subsystem without excessive complications.
The Basic circuit and modified circuit elements are designed using relevant equations. The simulation
circuits are developed using elements of simulink library. The Simulation is successfully done and open loop /
closed loop simulation results are presented. The Simulation results coincide with the theoretical results.
References
[1] Jianghan Zhang, Jin Zhao, Dehong Zhou, and Chengguang Huang, High-Performance Fault Diagnosis in
PWM Voltage-Source Inverters for Vector-Controlled Induction Motor Drives, IEEE Transactions On
Power Electronics, Vol. 29, No. 11, November 2014.
[2] R. L. D. Ribeiro, C. B. Jacobina, E. R. C. da Silva, and A. M. N. Lima, Fault detection of open-switch
damage in voltage-fed PWM motor drive systems, IEEE Trans. Power Electron., vol. 18, no. 2, Mar-
2003, 587โ€“593.
[3] B. Lu and S. Sharma, A survey of IGBT fault diagnostic methods for three-phase power inverters, in
Proc. 2008 Int. Conf. Condition Monitoring Diagnosis, 2007, 756โ€“763.
[4] B. Lu and S. K. Sharma, A literature review of IGBT fault diagnostic and protection methods for power
inverters, IEEE Trans. Ind. Appl., vol. 45, no. 5, Sep./Oct. 2009, 1770โ€“1777.
[5] P. Gilreath and B. N. Singh, A new centroid based fault detection method for 3-phase inverter-fed
induction motors, in Proc. 2005 IEEE 36th Power Electron. Spec. Conf., vol. 1โ€“3, 2005, 2664โ€“2669.
[6] R. Peuget, S. Courtine, and J. P. Rognon, Fault detection and isolation on a PWM inverter by knowledge-
based model, IEEE Trans. Ind. Appl., vol. 34, no. 6, Nov./Dec. 1998, 1318โ€“1326.
[7] M. Trabelsi, M. Boussak, and A. Chaari, High performance single and multiple faults diagnosis in
voltage source inverter fed induction motor drives, in Proc. 2012 XXth Int. Conf. Elect. Mach., 2012,
1717โ€“1723.
[8] A. M. S. Mendes and A. J. M. Cardoso, Voltage source inverter fault diagnosis in variable speed AC
drives, by the average current Parkโ€™s vector approach, in Proc. Int. Conf. Elect. Machines Drives, 1999,
704 โ€“ 706.
[9] F. Zidani, D. Diallo, M. E. H. Benbouzid, and R. Nait-Said, A fuzzybased approach for the diagnosis of
fault modes in a voltage-fed PWM inverter induction motor drive, IEEE Trans. Ind. Electron., vol. 55, no.
2, Feb. 2008, 586โ€“593.
[10] N. M. A. Freire, J. O. Estima, and A. J. M. Cardoso, A voltage-based approach for open-circuit fault
diagnosis in voltage-fed SVM motor drives without extra hardware, in Proc. 2012 XXth Int. Conf. Elect.
Mach., 2012, 2378โ€“2383.
[11] C. Delpha, C. Hao, and D. Diallo, SVM based diagnosis of inverter fed induction machine drive: A new
challenge, in Proc. 38th Annu. Conf. IEEE Ind. Electron. Soc., 2012, 3931โ€“3936.
[12] S. M. Jung, J. S. Park, H. W. Kim, K. Y. Cho, and M. J. Youn, An MRAS based diagnosis of open-circuit
fault in PWM voltage source inverters for PM synchronous motor drive systems, IEEE Trans. Power
Electron., vol. 28, no. 5, May 2013, 2514โ€“2526.

More Related Content

What's hot

Control of Four Switch Three Phase Inverter Fed Induction Motor Drives Based ...
Control of Four Switch Three Phase Inverter Fed Induction Motor Drives Based ...Control of Four Switch Three Phase Inverter Fed Induction Motor Drives Based ...
Control of Four Switch Three Phase Inverter Fed Induction Motor Drives Based ...IJPEDS-IAES
ย 
FAULT DETECTION AND DIAGNOSIS OF INDUCTION MACHINE WITH ON-LINE PARAMETER PR...
FAULT DETECTION AND DIAGNOSIS OF INDUCTION MACHINE  WITH ON-LINE PARAMETER PR...FAULT DETECTION AND DIAGNOSIS OF INDUCTION MACHINE  WITH ON-LINE PARAMETER PR...
FAULT DETECTION AND DIAGNOSIS OF INDUCTION MACHINE WITH ON-LINE PARAMETER PR...Sheikh R Manihar Ahmed
ย 
Detection of Broken Bars in Three Phase Squirrel Cage Induction Motor using F...
Detection of Broken Bars in Three Phase Squirrel Cage Induction Motor using F...Detection of Broken Bars in Three Phase Squirrel Cage Induction Motor using F...
Detection of Broken Bars in Three Phase Squirrel Cage Induction Motor using F...Dr.NAGARAJAN. S
ย 
Current mode controlled fuzzy logic based inter leaved cuk converter SVM inve...
Current mode controlled fuzzy logic based inter leaved cuk converter SVM inve...Current mode controlled fuzzy logic based inter leaved cuk converter SVM inve...
Current mode controlled fuzzy logic based inter leaved cuk converter SVM inve...Dr.NAGARAJAN. S
ย 
Improved Torque Control Performance in Direct Torque Control using Optimal Sw...
Improved Torque Control Performance in Direct Torque Control using Optimal Sw...Improved Torque Control Performance in Direct Torque Control using Optimal Sw...
Improved Torque Control Performance in Direct Torque Control using Optimal Sw...IJPEDS-IAES
ย 
A robust diagnosis method for speed sensor fault based on stator currents in ...
A robust diagnosis method for speed sensor fault based on stator currents in ...A robust diagnosis method for speed sensor fault based on stator currents in ...
A robust diagnosis method for speed sensor fault based on stator currents in ...IJECEIAES
ย 
DSP-Based Sensorless Speed Control of a Permanent Magnet Synchronous Motor us...
DSP-Based Sensorless Speed Control of a Permanent Magnet Synchronous Motor us...DSP-Based Sensorless Speed Control of a Permanent Magnet Synchronous Motor us...
DSP-Based Sensorless Speed Control of a Permanent Magnet Synchronous Motor us...IJPEDS-IAES
ย 
Open switch fault diagnosis in three phase inverter
Open switch fault diagnosis in three phase inverterOpen switch fault diagnosis in three phase inverter
Open switch fault diagnosis in three phase invertereSAT Publishing House
ย 
An investigation on switching
An investigation on switchingAn investigation on switching
An investigation on switchingcsandit
ย 
Pi3426832691
Pi3426832691Pi3426832691
Pi3426832691IJERA Editor
ย 
A real-time fault diagnosis system for high-speed power system protection bas...
A real-time fault diagnosis system for high-speed power system protection bas...A real-time fault diagnosis system for high-speed power system protection bas...
A real-time fault diagnosis system for high-speed power system protection bas...IJECEIAES
ย 
An044259264
An044259264An044259264
An044259264IJERA Editor
ย 
Open switch fault diagnosis in three phase inverter using diagnostic variable...
Open switch fault diagnosis in three phase inverter using diagnostic variable...Open switch fault diagnosis in three phase inverter using diagnostic variable...
Open switch fault diagnosis in three phase inverter using diagnostic variable...eSAT Journals
ย 
Field oriented control of induction motor based on
Field oriented control  of induction motor based onField oriented control  of induction motor based on
Field oriented control of induction motor based onAMRITAKUMARI21408
ย 

What's hot (20)

Control of Four Switch Three Phase Inverter Fed Induction Motor Drives Based ...
Control of Four Switch Three Phase Inverter Fed Induction Motor Drives Based ...Control of Four Switch Three Phase Inverter Fed Induction Motor Drives Based ...
Control of Four Switch Three Phase Inverter Fed Induction Motor Drives Based ...
ย 
Indirect Pulse-vector Control of Wound Rotor Induction Motor Drive in ANSYS E...
Indirect Pulse-vector Control of Wound Rotor Induction Motor Drive in ANSYS E...Indirect Pulse-vector Control of Wound Rotor Induction Motor Drive in ANSYS E...
Indirect Pulse-vector Control of Wound Rotor Induction Motor Drive in ANSYS E...
ย 
FAULT DETECTION AND DIAGNOSIS OF INDUCTION MACHINE WITH ON-LINE PARAMETER PR...
FAULT DETECTION AND DIAGNOSIS OF INDUCTION MACHINE  WITH ON-LINE PARAMETER PR...FAULT DETECTION AND DIAGNOSIS OF INDUCTION MACHINE  WITH ON-LINE PARAMETER PR...
FAULT DETECTION AND DIAGNOSIS OF INDUCTION MACHINE WITH ON-LINE PARAMETER PR...
ย 
Speed Control of 3-phase Induction Motors under Fault Conditions Supplied by ...
Speed Control of 3-phase Induction Motors under Fault Conditions Supplied by ...Speed Control of 3-phase Induction Motors under Fault Conditions Supplied by ...
Speed Control of 3-phase Induction Motors under Fault Conditions Supplied by ...
ย 
Detection of Broken Bars in Three Phase Squirrel Cage Induction Motor using F...
Detection of Broken Bars in Three Phase Squirrel Cage Induction Motor using F...Detection of Broken Bars in Three Phase Squirrel Cage Induction Motor using F...
Detection of Broken Bars in Three Phase Squirrel Cage Induction Motor using F...
ย 
Current mode controlled fuzzy logic based inter leaved cuk converter SVM inve...
Current mode controlled fuzzy logic based inter leaved cuk converter SVM inve...Current mode controlled fuzzy logic based inter leaved cuk converter SVM inve...
Current mode controlled fuzzy logic based inter leaved cuk converter SVM inve...
ย 
DWT based Fault Diagnosis of Induction Motor
DWT based Fault Diagnosis of Induction MotorDWT based Fault Diagnosis of Induction Motor
DWT based Fault Diagnosis of Induction Motor
ย 
Improved Torque Control Performance in Direct Torque Control using Optimal Sw...
Improved Torque Control Performance in Direct Torque Control using Optimal Sw...Improved Torque Control Performance in Direct Torque Control using Optimal Sw...
Improved Torque Control Performance in Direct Torque Control using Optimal Sw...
ย 
New DTC strategy of multi-machines single-inverter systems for electric vehic...
New DTC strategy of multi-machines single-inverter systems for electric vehic...New DTC strategy of multi-machines single-inverter systems for electric vehic...
New DTC strategy of multi-machines single-inverter systems for electric vehic...
ย 
A robust diagnosis method for speed sensor fault based on stator currents in ...
A robust diagnosis method for speed sensor fault based on stator currents in ...A robust diagnosis method for speed sensor fault based on stator currents in ...
A robust diagnosis method for speed sensor fault based on stator currents in ...
ย 
DSP-Based Sensorless Speed Control of a Permanent Magnet Synchronous Motor us...
DSP-Based Sensorless Speed Control of a Permanent Magnet Synchronous Motor us...DSP-Based Sensorless Speed Control of a Permanent Magnet Synchronous Motor us...
DSP-Based Sensorless Speed Control of a Permanent Magnet Synchronous Motor us...
ย 
Open switch fault diagnosis in three phase inverter
Open switch fault diagnosis in three phase inverterOpen switch fault diagnosis in three phase inverter
Open switch fault diagnosis in three phase inverter
ย 
An investigation on switching
An investigation on switchingAn investigation on switching
An investigation on switching
ย 
Torque ripples improvement of direct torque controlled five-phase induction m...
Torque ripples improvement of direct torque controlled five-phase induction m...Torque ripples improvement of direct torque controlled five-phase induction m...
Torque ripples improvement of direct torque controlled five-phase induction m...
ย 
Pi3426832691
Pi3426832691Pi3426832691
Pi3426832691
ย 
A real-time fault diagnosis system for high-speed power system protection bas...
A real-time fault diagnosis system for high-speed power system protection bas...A real-time fault diagnosis system for high-speed power system protection bas...
A real-time fault diagnosis system for high-speed power system protection bas...
ย 
Newly fault-tolerant indirect vector control for traction inverter
Newly fault-tolerant indirect vector control for traction inverterNewly fault-tolerant indirect vector control for traction inverter
Newly fault-tolerant indirect vector control for traction inverter
ย 
An044259264
An044259264An044259264
An044259264
ย 
Open switch fault diagnosis in three phase inverter using diagnostic variable...
Open switch fault diagnosis in three phase inverter using diagnostic variable...Open switch fault diagnosis in three phase inverter using diagnostic variable...
Open switch fault diagnosis in three phase inverter using diagnostic variable...
ย 
Field oriented control of induction motor based on
Field oriented control  of induction motor based onField oriented control  of induction motor based on
Field oriented control of induction motor based on
ย 

Viewers also liked

Customer Satisfaction Level of Islamic Bank and Conventional Bank in Pakistan
Customer Satisfaction Level of Islamic Bank and Conventional Bank in PakistanCustomer Satisfaction Level of Islamic Bank and Conventional Bank in Pakistan
Customer Satisfaction Level of Islamic Bank and Conventional Bank in PakistanIOSR Journals
ย 
D1102032633
D1102032633D1102032633
D1102032633IOSR Journals
ย 
S01061136141
S01061136141S01061136141
S01061136141IOSR Journals
ย 
Possible Inverse Isotope effect in High Tc Superconductors Using the Non Vari...
Possible Inverse Isotope effect in High Tc Superconductors Using the Non Vari...Possible Inverse Isotope effect in High Tc Superconductors Using the Non Vari...
Possible Inverse Isotope effect in High Tc Superconductors Using the Non Vari...IOSR Journals
ย 
A classification of methods for frequent pattern mining
A classification of methods for frequent pattern miningA classification of methods for frequent pattern mining
A classification of methods for frequent pattern miningIOSR Journals
ย 
Capital Structure andCorporate Governance practices. Evidence from Listed Non...
Capital Structure andCorporate Governance practices. Evidence from Listed Non...Capital Structure andCorporate Governance practices. Evidence from Listed Non...
Capital Structure andCorporate Governance practices. Evidence from Listed Non...IOSR Journals
ย 
On Bernstein Polynomials
On Bernstein PolynomialsOn Bernstein Polynomials
On Bernstein PolynomialsIOSR Journals
ย 
Determination of volatile organic compounds in surface water and sediment usi...
Determination of volatile organic compounds in surface water and sediment usi...Determination of volatile organic compounds in surface water and sediment usi...
Determination of volatile organic compounds in surface water and sediment usi...IOSR Journals
ย 
Market Orientation, Firmsโ€™ Level Characteristics and Environmental Factors: I...
Market Orientation, Firmsโ€™ Level Characteristics and Environmental Factors: I...Market Orientation, Firmsโ€™ Level Characteristics and Environmental Factors: I...
Market Orientation, Firmsโ€™ Level Characteristics and Environmental Factors: I...IOSR Journals
ย 
Implementation of an Improved Microcontroller Based Moving Message Display Sy...
Implementation of an Improved Microcontroller Based Moving Message Display Sy...Implementation of an Improved Microcontroller Based Moving Message Display Sy...
Implementation of an Improved Microcontroller Based Moving Message Display Sy...IOSR Journals
ย 
Performance of Concrete at Elevated Temperatures: Utilizing A Blended Ordinar...
Performance of Concrete at Elevated Temperatures: Utilizing A Blended Ordinar...Performance of Concrete at Elevated Temperatures: Utilizing A Blended Ordinar...
Performance of Concrete at Elevated Temperatures: Utilizing A Blended Ordinar...IOSR Journals
ย 
FTIR study of second group iodate crystals grown by gel method
FTIR study of second group iodate crystals grown by gel methodFTIR study of second group iodate crystals grown by gel method
FTIR study of second group iodate crystals grown by gel methodIOSR Journals
ย 
Fatliquor preparation from Karanja seed oil (Pongamia pinnata L.) and its app...
Fatliquor preparation from Karanja seed oil (Pongamia pinnata L.) and its app...Fatliquor preparation from Karanja seed oil (Pongamia pinnata L.) and its app...
Fatliquor preparation from Karanja seed oil (Pongamia pinnata L.) and its app...IOSR Journals
ย 
Numerical Investigation of Higher Order Nonlinear Problem in the Calculus Of ...
Numerical Investigation of Higher Order Nonlinear Problem in the Calculus Of ...Numerical Investigation of Higher Order Nonlinear Problem in the Calculus Of ...
Numerical Investigation of Higher Order Nonlinear Problem in the Calculus Of ...IOSR Journals
ย 
Effect of Notch Angle on the Fracture Toughness of Al7075 T6 Alloy- An Experi...
Effect of Notch Angle on the Fracture Toughness of Al7075 T6 Alloy- An Experi...Effect of Notch Angle on the Fracture Toughness of Al7075 T6 Alloy- An Experi...
Effect of Notch Angle on the Fracture Toughness of Al7075 T6 Alloy- An Experi...IOSR Journals
ย 
Estimation of Damping Derivative of a Delta Wing with Half Sine Wave Curved L...
Estimation of Damping Derivative of a Delta Wing with Half Sine Wave Curved L...Estimation of Damping Derivative of a Delta Wing with Half Sine Wave Curved L...
Estimation of Damping Derivative of a Delta Wing with Half Sine Wave Curved L...IOSR Journals
ย 

Viewers also liked (20)

Customer Satisfaction Level of Islamic Bank and Conventional Bank in Pakistan
Customer Satisfaction Level of Islamic Bank and Conventional Bank in PakistanCustomer Satisfaction Level of Islamic Bank and Conventional Bank in Pakistan
Customer Satisfaction Level of Islamic Bank and Conventional Bank in Pakistan
ย 
D1102032633
D1102032633D1102032633
D1102032633
ย 
S01061136141
S01061136141S01061136141
S01061136141
ย 
F017624449
F017624449F017624449
F017624449
ย 
C012331527
C012331527C012331527
C012331527
ย 
Possible Inverse Isotope effect in High Tc Superconductors Using the Non Vari...
Possible Inverse Isotope effect in High Tc Superconductors Using the Non Vari...Possible Inverse Isotope effect in High Tc Superconductors Using the Non Vari...
Possible Inverse Isotope effect in High Tc Superconductors Using the Non Vari...
ย 
A classification of methods for frequent pattern mining
A classification of methods for frequent pattern miningA classification of methods for frequent pattern mining
A classification of methods for frequent pattern mining
ย 
Capital Structure andCorporate Governance practices. Evidence from Listed Non...
Capital Structure andCorporate Governance practices. Evidence from Listed Non...Capital Structure andCorporate Governance practices. Evidence from Listed Non...
Capital Structure andCorporate Governance practices. Evidence from Listed Non...
ย 
On Bernstein Polynomials
On Bernstein PolynomialsOn Bernstein Polynomials
On Bernstein Polynomials
ย 
Determination of volatile organic compounds in surface water and sediment usi...
Determination of volatile organic compounds in surface water and sediment usi...Determination of volatile organic compounds in surface water and sediment usi...
Determination of volatile organic compounds in surface water and sediment usi...
ย 
G012334650
G012334650G012334650
G012334650
ย 
Market Orientation, Firmsโ€™ Level Characteristics and Environmental Factors: I...
Market Orientation, Firmsโ€™ Level Characteristics and Environmental Factors: I...Market Orientation, Firmsโ€™ Level Characteristics and Environmental Factors: I...
Market Orientation, Firmsโ€™ Level Characteristics and Environmental Factors: I...
ย 
Implementation of an Improved Microcontroller Based Moving Message Display Sy...
Implementation of an Improved Microcontroller Based Moving Message Display Sy...Implementation of an Improved Microcontroller Based Moving Message Display Sy...
Implementation of an Improved Microcontroller Based Moving Message Display Sy...
ย 
Performance of Concrete at Elevated Temperatures: Utilizing A Blended Ordinar...
Performance of Concrete at Elevated Temperatures: Utilizing A Blended Ordinar...Performance of Concrete at Elevated Temperatures: Utilizing A Blended Ordinar...
Performance of Concrete at Elevated Temperatures: Utilizing A Blended Ordinar...
ย 
FTIR study of second group iodate crystals grown by gel method
FTIR study of second group iodate crystals grown by gel methodFTIR study of second group iodate crystals grown by gel method
FTIR study of second group iodate crystals grown by gel method
ย 
Fatliquor preparation from Karanja seed oil (Pongamia pinnata L.) and its app...
Fatliquor preparation from Karanja seed oil (Pongamia pinnata L.) and its app...Fatliquor preparation from Karanja seed oil (Pongamia pinnata L.) and its app...
Fatliquor preparation from Karanja seed oil (Pongamia pinnata L.) and its app...
ย 
B0610611
B0610611B0610611
B0610611
ย 
Numerical Investigation of Higher Order Nonlinear Problem in the Calculus Of ...
Numerical Investigation of Higher Order Nonlinear Problem in the Calculus Of ...Numerical Investigation of Higher Order Nonlinear Problem in the Calculus Of ...
Numerical Investigation of Higher Order Nonlinear Problem in the Calculus Of ...
ย 
Effect of Notch Angle on the Fracture Toughness of Al7075 T6 Alloy- An Experi...
Effect of Notch Angle on the Fracture Toughness of Al7075 T6 Alloy- An Experi...Effect of Notch Angle on the Fracture Toughness of Al7075 T6 Alloy- An Experi...
Effect of Notch Angle on the Fracture Toughness of Al7075 T6 Alloy- An Experi...
ย 
Estimation of Damping Derivative of a Delta Wing with Half Sine Wave Curved L...
Estimation of Damping Derivative of a Delta Wing with Half Sine Wave Curved L...Estimation of Damping Derivative of a Delta Wing with Half Sine Wave Curved L...
Estimation of Damping Derivative of a Delta Wing with Half Sine Wave Curved L...
ย 

Similar to B010620715

Open-Switch Fault-Tolerant Control of a Grid-Side Converter in a Wind Power G...
Open-Switch Fault-Tolerant Control of a Grid-Side Converter in a Wind Power G...Open-Switch Fault-Tolerant Control of a Grid-Side Converter in a Wind Power G...
Open-Switch Fault-Tolerant Control of a Grid-Side Converter in a Wind Power G...IJPEDS-IAES
ย 
Induction motor modelling and applications report
Induction motor modelling and applications reportInduction motor modelling and applications report
Induction motor modelling and applications reportUmesh Dadde
ย 
14. a variable speed, sensorless, induction motor drive
14. a variable speed, sensorless, induction motor drive14. a variable speed, sensorless, induction motor drive
14. a variable speed, sensorless, induction motor drivesatya_m
ย 
IRJET- A Review on SVM based Induction Motor
IRJET- A Review on SVM based Induction MotorIRJET- A Review on SVM based Induction Motor
IRJET- A Review on SVM based Induction MotorIRJET Journal
ย 
Kf3517721775
Kf3517721775Kf3517721775
Kf3517721775IJERA Editor
ย 
OPTIMAL TORQUE RIPPLE CONTROL OF ASYNCHRONOUS DRIVE USING INTELLIGENT CONTROL...
OPTIMAL TORQUE RIPPLE CONTROL OF ASYNCHRONOUS DRIVE USING INTELLIGENT CONTROL...OPTIMAL TORQUE RIPPLE CONTROL OF ASYNCHRONOUS DRIVE USING INTELLIGENT CONTROL...
OPTIMAL TORQUE RIPPLE CONTROL OF ASYNCHRONOUS DRIVE USING INTELLIGENT CONTROL...elelijjournal
ย 
Review of the DTC Controller and Estimation of Stator Resistance in IM Drives
Review of the DTC Controller and Estimation of Stator Resistance in IM DrivesReview of the DTC Controller and Estimation of Stator Resistance in IM Drives
Review of the DTC Controller and Estimation of Stator Resistance in IM DrivesIAES-IJPEDS
ย 
IRJET- Speed Control and Minimization of Torque Ripples in BLDC Motor usi...
IRJET-  	  Speed Control and Minimization of Torque Ripples in BLDC Motor usi...IRJET-  	  Speed Control and Minimization of Torque Ripples in BLDC Motor usi...
IRJET- Speed Control and Minimization of Torque Ripples in BLDC Motor usi...IRJET Journal
ย 
Automation and Calibration for Discrete Transducer: A Survey
Automation and Calibration for Discrete Transducer: A SurveyAutomation and Calibration for Discrete Transducer: A Survey
Automation and Calibration for Discrete Transducer: A SurveyIRJET Journal
ย 
A Novel Optimal PI Parameter Tuning Strategy to Improve Constant Switching Pe...
A Novel Optimal PI Parameter Tuning Strategy to Improve Constant Switching Pe...A Novel Optimal PI Parameter Tuning Strategy to Improve Constant Switching Pe...
A Novel Optimal PI Parameter Tuning Strategy to Improve Constant Switching Pe...IJPEDS-IAES
ย 
Induction motor harmonic reduction using space vector modulation algorithm
Induction motor harmonic reduction using space vector modulation algorithmInduction motor harmonic reduction using space vector modulation algorithm
Induction motor harmonic reduction using space vector modulation algorithmjournalBEEI
ย 
Parkโ€™s Vector Approach to detect an inter turn stator fault in a doubly fed i...
Parkโ€™s Vector Approach to detect an inter turn stator fault in a doubly fed i...Parkโ€™s Vector Approach to detect an inter turn stator fault in a doubly fed i...
Parkโ€™s Vector Approach to detect an inter turn stator fault in a doubly fed i...cscpconf
ย 
Speed Control of FSTP Inverter Fed Induction Motor Drive with a Neural Networ...
Speed Control of FSTP Inverter Fed Induction Motor Drive with a Neural Networ...Speed Control of FSTP Inverter Fed Induction Motor Drive with a Neural Networ...
Speed Control of FSTP Inverter Fed Induction Motor Drive with a Neural Networ...IOSR Journals
ย 
Comparison of different controllers for the improvement of Dynamic response o...
Comparison of different controllers for the improvement of Dynamic response o...Comparison of different controllers for the improvement of Dynamic response o...
Comparison of different controllers for the improvement of Dynamic response o...IJERA Editor
ย 

Similar to B010620715 (20)

Open-Switch Fault-Tolerant Control of a Grid-Side Converter in a Wind Power G...
Open-Switch Fault-Tolerant Control of a Grid-Side Converter in a Wind Power G...Open-Switch Fault-Tolerant Control of a Grid-Side Converter in a Wind Power G...
Open-Switch Fault-Tolerant Control of a Grid-Side Converter in a Wind Power G...
ย 
Induction motor modelling and applications report
Induction motor modelling and applications reportInduction motor modelling and applications report
Induction motor modelling and applications report
ย 
M356872
M356872M356872
M356872
ย 
Machine learning based multi class fault diagnosis tool for voltage source in...
Machine learning based multi class fault diagnosis tool for voltage source in...Machine learning based multi class fault diagnosis tool for voltage source in...
Machine learning based multi class fault diagnosis tool for voltage source in...
ย 
14. a variable speed, sensorless, induction motor drive
14. a variable speed, sensorless, induction motor drive14. a variable speed, sensorless, induction motor drive
14. a variable speed, sensorless, induction motor drive
ย 
IRJET- A Review on SVM based Induction Motor
IRJET- A Review on SVM based Induction MotorIRJET- A Review on SVM based Induction Motor
IRJET- A Review on SVM based Induction Motor
ย 
Enhanced Three-Phase Inverter Faults Detection And Diagnosis Approach - Desig...
Enhanced Three-Phase Inverter Faults Detection And Diagnosis Approach - Desig...Enhanced Three-Phase Inverter Faults Detection And Diagnosis Approach - Desig...
Enhanced Three-Phase Inverter Faults Detection And Diagnosis Approach - Desig...
ย 
Kf3517721775
Kf3517721775Kf3517721775
Kf3517721775
ย 
OPTIMAL TORQUE RIPPLE CONTROL OF ASYNCHRONOUS DRIVE USING INTELLIGENT CONTROL...
OPTIMAL TORQUE RIPPLE CONTROL OF ASYNCHRONOUS DRIVE USING INTELLIGENT CONTROL...OPTIMAL TORQUE RIPPLE CONTROL OF ASYNCHRONOUS DRIVE USING INTELLIGENT CONTROL...
OPTIMAL TORQUE RIPPLE CONTROL OF ASYNCHRONOUS DRIVE USING INTELLIGENT CONTROL...
ย 
Review of the DTC Controller and Estimation of Stator Resistance in IM Drives
Review of the DTC Controller and Estimation of Stator Resistance in IM DrivesReview of the DTC Controller and Estimation of Stator Resistance in IM Drives
Review of the DTC Controller and Estimation of Stator Resistance in IM Drives
ย 
An efficient predictive current controller with adaptive parameter estimation...
An efficient predictive current controller with adaptive parameter estimation...An efficient predictive current controller with adaptive parameter estimation...
An efficient predictive current controller with adaptive parameter estimation...
ย 
IRJET- Speed Control and Minimization of Torque Ripples in BLDC Motor usi...
IRJET-  	  Speed Control and Minimization of Torque Ripples in BLDC Motor usi...IRJET-  	  Speed Control and Minimization of Torque Ripples in BLDC Motor usi...
IRJET- Speed Control and Minimization of Torque Ripples in BLDC Motor usi...
ย 
Automation and Calibration for Discrete Transducer: A Survey
Automation and Calibration for Discrete Transducer: A SurveyAutomation and Calibration for Discrete Transducer: A Survey
Automation and Calibration for Discrete Transducer: A Survey
ย 
A Novel Optimal PI Parameter Tuning Strategy to Improve Constant Switching Pe...
A Novel Optimal PI Parameter Tuning Strategy to Improve Constant Switching Pe...A Novel Optimal PI Parameter Tuning Strategy to Improve Constant Switching Pe...
A Novel Optimal PI Parameter Tuning Strategy to Improve Constant Switching Pe...
ย 
Induction motor harmonic reduction using space vector modulation algorithm
Induction motor harmonic reduction using space vector modulation algorithmInduction motor harmonic reduction using space vector modulation algorithm
Induction motor harmonic reduction using space vector modulation algorithm
ย 
Parkโ€™s Vector Approach to detect an inter turn stator fault in a doubly fed i...
Parkโ€™s Vector Approach to detect an inter turn stator fault in a doubly fed i...Parkโ€™s Vector Approach to detect an inter turn stator fault in a doubly fed i...
Parkโ€™s Vector Approach to detect an inter turn stator fault in a doubly fed i...
ย 
38
3838
38
ย 
Speed Control of FSTP Inverter Fed Induction Motor Drive with a Neural Networ...
Speed Control of FSTP Inverter Fed Induction Motor Drive with a Neural Networ...Speed Control of FSTP Inverter Fed Induction Motor Drive with a Neural Networ...
Speed Control of FSTP Inverter Fed Induction Motor Drive with a Neural Networ...
ย 
C010141422
C010141422C010141422
C010141422
ย 
Comparison of different controllers for the improvement of Dynamic response o...
Comparison of different controllers for the improvement of Dynamic response o...Comparison of different controllers for the improvement of Dynamic response o...
Comparison of different controllers for the improvement of Dynamic response o...
ย 

More from IOSR Journals

More from IOSR Journals (20)

A011140104
A011140104A011140104
A011140104
ย 
M0111397100
M0111397100M0111397100
M0111397100
ย 
L011138596
L011138596L011138596
L011138596
ย 
K011138084
K011138084K011138084
K011138084
ย 
J011137479
J011137479J011137479
J011137479
ย 
I011136673
I011136673I011136673
I011136673
ย 
G011134454
G011134454G011134454
G011134454
ย 
H011135565
H011135565H011135565
H011135565
ย 
F011134043
F011134043F011134043
F011134043
ย 
E011133639
E011133639E011133639
E011133639
ย 
D011132635
D011132635D011132635
D011132635
ย 
C011131925
C011131925C011131925
C011131925
ย 
B011130918
B011130918B011130918
B011130918
ย 
A011130108
A011130108A011130108
A011130108
ย 
I011125160
I011125160I011125160
I011125160
ย 
H011124050
H011124050H011124050
H011124050
ย 
G011123539
G011123539G011123539
G011123539
ย 
F011123134
F011123134F011123134
F011123134
ย 
E011122530
E011122530E011122530
E011122530
ย 
D011121524
D011121524D011121524
D011121524
ย 

Recently uploaded

My INSURER PTE LTD - Insurtech Innovation Award 2024
My INSURER PTE LTD - Insurtech Innovation Award 2024My INSURER PTE LTD - Insurtech Innovation Award 2024
My INSURER PTE LTD - Insurtech Innovation Award 2024The Digital Insurer
ย 
Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024Scott Keck-Warren
ย 
Integration and Automation in Practice: CI/CD in Muleย Integration and Automat...
Integration and Automation in Practice: CI/CD in Muleย Integration and Automat...Integration and Automation in Practice: CI/CD in Muleย Integration and Automat...
Integration and Automation in Practice: CI/CD in Muleย Integration and Automat...Patryk Bandurski
ย 
Install Stable Diffusion in windows machine
Install Stable Diffusion in windows machineInstall Stable Diffusion in windows machine
Install Stable Diffusion in windows machinePadma Pradeep
ย 
Benefits Of Flutter Compared To Other Frameworks
Benefits Of Flutter Compared To Other FrameworksBenefits Of Flutter Compared To Other Frameworks
Benefits Of Flutter Compared To Other FrameworksSoftradix Technologies
ย 
DMCC Future of Trade Web3 - Special Edition
DMCC Future of Trade Web3 - Special EditionDMCC Future of Trade Web3 - Special Edition
DMCC Future of Trade Web3 - Special EditionDubai Multi Commodity Centre
ย 
Human Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsHuman Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsMark Billinghurst
ย 
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024BookNet Canada
ย 
Artificial intelligence in the post-deep learning era
Artificial intelligence in the post-deep learning eraArtificial intelligence in the post-deep learning era
Artificial intelligence in the post-deep learning eraDeakin University
ย 
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks..."LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...Fwdays
ย 
Bluetooth Controlled Car with Arduino.pdf
Bluetooth Controlled Car with Arduino.pdfBluetooth Controlled Car with Arduino.pdf
Bluetooth Controlled Car with Arduino.pdfngoud9212
ย 
Swan(sea) Song โ€“ personal research during my six years at Swansea ... and bey...
Swan(sea) Song โ€“ personal research during my six years at Swansea ... and bey...Swan(sea) Song โ€“ personal research during my six years at Swansea ... and bey...
Swan(sea) Song โ€“ personal research during my six years at Swansea ... and bey...Alan Dix
ย 
AI as an Interface for Commercial Buildings
AI as an Interface for Commercial BuildingsAI as an Interface for Commercial Buildings
AI as an Interface for Commercial BuildingsMemoori
ย 
Hot Sexy call girls in Panjabi Bagh ๐Ÿ” 9953056974 ๐Ÿ” Delhi escort Service
Hot Sexy call girls in Panjabi Bagh ๐Ÿ” 9953056974 ๐Ÿ” Delhi escort ServiceHot Sexy call girls in Panjabi Bagh ๐Ÿ” 9953056974 ๐Ÿ” Delhi escort Service
Hot Sexy call girls in Panjabi Bagh ๐Ÿ” 9953056974 ๐Ÿ” Delhi escort Service9953056974 Low Rate Call Girls In Saket, Delhi NCR
ย 
Key Features Of Token Development (1).pptx
Key  Features Of Token  Development (1).pptxKey  Features Of Token  Development (1).pptx
Key Features Of Token Development (1).pptxLBM Solutions
ย 
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024BookNet Canada
ย 
My Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationMy Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationRidwan Fadjar
ย 
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersEnhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersThousandEyes
ย 
APIForce Zurich 5 April Automation LPDG
APIForce Zurich 5 April  Automation LPDGAPIForce Zurich 5 April  Automation LPDG
APIForce Zurich 5 April Automation LPDGMarianaLemus7
ย 

Recently uploaded (20)

My INSURER PTE LTD - Insurtech Innovation Award 2024
My INSURER PTE LTD - Insurtech Innovation Award 2024My INSURER PTE LTD - Insurtech Innovation Award 2024
My INSURER PTE LTD - Insurtech Innovation Award 2024
ย 
Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024
ย 
Integration and Automation in Practice: CI/CD in Muleย Integration and Automat...
Integration and Automation in Practice: CI/CD in Muleย Integration and Automat...Integration and Automation in Practice: CI/CD in Muleย Integration and Automat...
Integration and Automation in Practice: CI/CD in Muleย Integration and Automat...
ย 
Install Stable Diffusion in windows machine
Install Stable Diffusion in windows machineInstall Stable Diffusion in windows machine
Install Stable Diffusion in windows machine
ย 
Benefits Of Flutter Compared To Other Frameworks
Benefits Of Flutter Compared To Other FrameworksBenefits Of Flutter Compared To Other Frameworks
Benefits Of Flutter Compared To Other Frameworks
ย 
DMCC Future of Trade Web3 - Special Edition
DMCC Future of Trade Web3 - Special EditionDMCC Future of Trade Web3 - Special Edition
DMCC Future of Trade Web3 - Special Edition
ย 
Human Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsHuman Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR Systems
ย 
E-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptx
E-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptxE-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptx
E-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptx
ย 
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
ย 
Artificial intelligence in the post-deep learning era
Artificial intelligence in the post-deep learning eraArtificial intelligence in the post-deep learning era
Artificial intelligence in the post-deep learning era
ย 
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks..."LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
ย 
Bluetooth Controlled Car with Arduino.pdf
Bluetooth Controlled Car with Arduino.pdfBluetooth Controlled Car with Arduino.pdf
Bluetooth Controlled Car with Arduino.pdf
ย 
Swan(sea) Song โ€“ personal research during my six years at Swansea ... and bey...
Swan(sea) Song โ€“ personal research during my six years at Swansea ... and bey...Swan(sea) Song โ€“ personal research during my six years at Swansea ... and bey...
Swan(sea) Song โ€“ personal research during my six years at Swansea ... and bey...
ย 
AI as an Interface for Commercial Buildings
AI as an Interface for Commercial BuildingsAI as an Interface for Commercial Buildings
AI as an Interface for Commercial Buildings
ย 
Hot Sexy call girls in Panjabi Bagh ๐Ÿ” 9953056974 ๐Ÿ” Delhi escort Service
Hot Sexy call girls in Panjabi Bagh ๐Ÿ” 9953056974 ๐Ÿ” Delhi escort ServiceHot Sexy call girls in Panjabi Bagh ๐Ÿ” 9953056974 ๐Ÿ” Delhi escort Service
Hot Sexy call girls in Panjabi Bagh ๐Ÿ” 9953056974 ๐Ÿ” Delhi escort Service
ย 
Key Features Of Token Development (1).pptx
Key  Features Of Token  Development (1).pptxKey  Features Of Token  Development (1).pptx
Key Features Of Token Development (1).pptx
ย 
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
ย 
My Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationMy Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 Presentation
ย 
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersEnhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
ย 
APIForce Zurich 5 April Automation LPDG
APIForce Zurich 5 April  Automation LPDGAPIForce Zurich 5 April  Automation LPDG
APIForce Zurich 5 April Automation LPDG
ย 

B010620715

  • 1. IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331, Volume 10, Issue 6 Ver. II (Nov โ€“ Dec. 2015), PP 07-15 www.iosrjournals.org DOI: 10.9790/1676-10620715 www.iosrjournals.org 7 | Page Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Induction Motor Drives Varsharani J. More1 , N. G. Kulkarni2 , Dr. R. M. Nagarale3 1(PG student, M.B.E. Societyโ€™s college of engineering, Ambajogai, Maharashtra, India) 2,3 (PG Department, M.B.E. Societyโ€™s College of engineering, Ambajogai, Maharashtra, India) Abstract : This paper presents a simple method for isolation of open circuit fault in pulse width modulated voltage source inverters (PWM VSIs) feeding vector controlled induction motor drives. The VSI operation process is repeated over the period of time. This repetitive operation is divided into six operating statges by certain rules depending upon the phase angle of one phase current. At each stage, only three power switches make vital influece and the other three perform negligible influence on the operation of VSI. The open circuit fault affects the operation and introduces the repetitive distortions in current waveforms. These distortions are observed at faulty stage and gets disappeared at healthy stage. Here, fuzzy logic controller is used for isolation of fault which shows itโ€™s effectiveness in simulations and results. Keywords โ€“ Fault detection, fault isolation, fuzzy logic controller, open circuit fault. PWM VSI. I. Introduction The electric drive systems are used widely in the most of industrial manufacturing processes. Many times these drive systems are exposed to overloading or different environmental conditions, which result into aging process, to faults concern with induction motor or the inverter. These faults can be the reason for unpredicted downtime or damages to human life. Hence demand for maintainability and reliability is increasing largely. Fig.1. General configuration of an induction motor drive system Generally, a motor drive system includes a microcontroller unit (MCU) for implementation of the control algorithms, a power electronic device such as pulse width modulated voltage source inverter (PWM VSI), and an induction motor as shown in Fig.1. Within this drive system, faults can occur in the inverter, dc bus, or in the motor itself. A voltage-source inverter is the most commonly used inverter topology in these systems and also in power quality applications. By considering their complexity, these power converters are found very susceptible in suffering critical failures. The fact is that about 38% of the failures in variable speed ac drives in industry are occurred in power electronics [1]. Recently, a survey of reliability in power electronic converters shows that semiconductor power device is the most fragile component, which is followed by capacitors and gate drives [2]. Now-a-days, the power converters designed for industrial use can be equipped with some diagnostic units to protect against disturbances and execute a shutdown in case of severe faults in order to avoid greater damages. It has become a standard feature for the inverters to protect against power transistor over current or short circuit by monitoring the transistor collectorโ€“emitter voltage but the open-circuit failures often cause slow
  • 2. Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Inductionโ€ฆ DOI: 10.9790/1676-10620715 www.iosrjournals.org 8 | Page response. This type of fault may result the disconnection of the semiconductor due to lifting of bonding wires caused by thermic cycling or due to a problem in the gate control signal [3]. This kind of failure does not necessarily cause the system shutdown and can remain undetected for an extended period of time [4]. Since, it degrades the performance of the system by causing the operating topology imbalance, raising the current pressure of healthy transistors and thus a secondary fault may occur in the converter or in the remaining drive components which may result the total system shutdown and higher repairing costs, or even personal injury. So this paper introduces a simple and effective approach for detection of the open-circuit faults in inverter switches and isolation by using fuzzy logic controller. Several papers and research works have been published and developed in the literature on the open- circuit fault diagnosis in the motor drive systems. Initially, a fault tolerant system was proposed for a brushless DC motor [4]. Further, the methods based on voltage, such as the error voltage method which compares the actual voltage with voltage command and lower switch voltage method [5], where the measurement of the voltages is used, show a fast diagnosis performance and thus reduce the time between the fault occurrence and diagnosis. But its major drawback is to increase system cost as it requires extra hardware equipments such as voltage sensors and electric circuits. The centroid determination method presented in [6] detects and identifies the faults in an inverter-fed induction motor from the centroid of the three-phase currents transformed from a โˆ’ b โ€“ c to ฮฑ โˆ’ ฮฒ plane. In [7], two methods based on the analysis of these current vectors are proposed by the authors. The first one is known as slope method which uses the current vector trajectory in the Concordia plane to detect and localize faults on a PWM inverter. The second is called instantaneous frequency method that allows to detect an inverter fault, but not to identify the faulty switch. Moreover, the Park current vector method was introduced in [8], [9] by monitoring the average motor supply current trajectory to diagnose the faults in variable speed ac drives. The main drawback of all these earlier mentioned methods is the susceptibility to the load torque. In [9], the authors suggested the normalized direct component (DC) current method. To make the scheme independent from the load, the mean values of the three-phase currents are divided by the absolute value of its own first harmonic coefficients and by comparing with a threshold, faults are diagnosed. These suggested current-based methods have shown active performances in current open-loop control scheme such as scalar (V /f) control, but are not seen quite effective in current closed-loop control scheme such as vector control [10]. Fig.2. Ordinary indirect vector control system of an induction motor. In this paper a simple method for detection and isolation of open-circuit faults of VSI feeding a vector- controlled induction motor drive by using fuzzy logic controller is presented. The principle of vector control gives a deep analysis and thus the relative features such as change in current distortions in faulty condition are obtained to detect and identify the faults. In this proposed scheme waveforms for three different conditions are observed: 1) Open loop response at normal stage, 2) open loop response with fault and 3) closed loop response with fault using controller. By introducing the fault in the circuit and setting required reference speed, the simulation results are obtained. These results are introduced with a distortion in current waveforms due to fault. In order to overcome this faulty stage, a fuzzy logic controller is used. The proposed fault isolation is configured without extra hardware equipment and excessive computational effort and thus allows to be embedded into an existing vector-controlled induction motor drive system. To test and validate the proposed method, open-circuit faults are introduced in the VSI for a vector-controlled induction motor drive. Simulation results show the validity of the proposed approach. II. Open-Circuit Fault Analysis In The VSI When a transistor of an inverter does not work or turn on, the phase current of a machine are no longer sinusoidal. In a majority of fault detection methods, used for induction motor drives, three phase currents are
  • 3. Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Inductionโ€ฆ DOI: 10.9790/1676-10620715 www.iosrjournals.org 9 | Page inputs for detection of faults. The ultimate purpose of vector control is to drive the induction motor as a shunt- wound dc motor which means to control the field excitation and the torque-generating current separately. Fig.2 shows an ordinary indirect vector control system of an induction motor drive without consideration of flux weakening. Here, the three phase currents are first transformed by using coordinate transformation into two synchronously rotating Cartesian vector components id and iq which are controlled independently to control the rotor flux and torque respectively. It can be expressed by the set of equations with dโ€“q frame with rotor-flux orientation. ๐‘‡๐‘’ = ๐‘› ๐‘ ๐ฟ ๐‘š ๐ฟ๐‘Ÿ ๏™ ๐‘Ÿ ๐‘– ๐‘ž (1) ๏™ ๐‘Ÿ = ๐ฟ ๐‘š ๐ฟ ๐‘Ÿ ๐‘… ๐‘Ÿ ๐‘ +1 ๐‘– ๐‘‘ (2) where, id and iq denote d- and q-axis rotor currents, ฯˆr is the rotor flux in rotor reference frame, Te stands for the electromagnetic torque, np is the number of pole pairs, Lm and Lr are the magnetizing inductance and rotor self-inductance, respectively, Rr is the rotor resistance, and p is the differential operator d/dt. The currents id and iq in the dโˆ’q frame can be derived from the currents in the ฮฑโˆ’ฮฒ frame by Park transformation which is defined as ๐‘– ๐‘‘ = ๐‘– ๐›ผ ๐‘๐‘œ๐‘  ๐œƒ + ๐‘– ๐›ฝ ๐‘ ๐‘–๐‘› ๐œƒ (3) ๐‘– ๐‘ž = โˆ’๐‘– ๐›ผ ๐‘ ๐‘–๐‘› ๐œƒ + ๐‘– ๐›ฝ ๐‘๐‘œ๐‘  ๐œƒ (4) where ฮธ is the rotor flux angle or transform angle, generated from the speed signal and slip signal and the currents iฮฑ and iฮฒ in stationary frame are transformed by Clarke transformation defined as ๐‘– ๐›ผ = 2 3 ๐‘– ๐‘Ž โˆ’ 1 2 ๐‘– ๐‘ โˆ’ 1 2 ๐‘– ๐‘ (5) ๐‘– ๐›ฝ = 2 3 3 2 ๐‘– ๐‘ โˆ’ 3 2 ๐‘– ๐‘ (6) where ia , ib and ic are the motor phase currents. The vector control is based on projections which transform a three-phase time and speed dependent system into a two-coordinate (d- and q-coordinate) time invariant system and lead to a structure similar to a dc machine control. The vector control machine needs two variables as input references: the torque component (i* q ) and the flux component (i* d). The vector control structure handles the instantaneous electrical quantities, as it is based on projections. This makes the control accurate in every working operation (steady states and transient) and independent of the limited bandwidth mathematical model. Without consideration of flux weakening, the amplitude of the rotor flux (ฯˆr) is maintained at a fixed value and thus there is a linear relationship between torque and torque component (iq). Thereby, the torque can be control by controlling the torque component of stator current vector. With regard to the current, the complex stator current vector is defined by ๐‘– ๐‘  = ๐‘– ๐‘Ž + ๏ง๐‘– ๐‘ + ๏ง2 ๐‘– ๐‘ = ๐‘– ๐‘‘ + ๐‘– ๐‘ž = ๐‘– ๐›ผ + ๐‘– ๐›ฝ (7) where ฮณ = ej2ฯ€/3 and ฮณ = ej4ฯ€/3 represent the spatial operator. Considering the d-axis aligned with the rotor flux, Fig. 3 shows the relationship between the ฮฑ โˆ’ ฮฒ reference frame and the d โˆ’ q frame. Fig.3. Current vector in the d โˆ’ q frame and its relationship with the ฮฑ โ€“ ฮฒ frame.
  • 4. Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Inductionโ€ฆ DOI: 10.9790/1676-10620715 www.iosrjournals.org 10 | Page Fig.4. Three-phase currents distribution in the power switches III. Design Of Proposed FLC The main reason for choosing a fuzzy approach is the very nature of the changes in the attributes. It is nonlinear, and in addition, it would be unreasonable to expect that each time the same level of a particular fault arises, the attributes would measure exactly the same values. The boundaries between two levels of a certain fault are not sharply defined, and therefore the use of a fuzzy logic control is appropriate. Membership functions and the degree of membership, rather than yes or no membership, give the opportunity, using previously acquired knowledge about the system attributes. Fig.5. Structure of Proposed FLC The input membership functions are usually a symmetric triangle with equal distribution over the universe of discourse. The formulation of membership functions of output variables show more variety frequently. In FLC design, one should identify the main control variables and determine the sets that describe the values of each linguistic variable. The specific structure of the FLC is shown in Fig.5. The input variables of the FLC are the reference speed and the change in the speed. The triangular membership functions are used for the FLC for easier computation. The Mamdani fuzzy inference method is used for the proposed FLC. In this controller, membership functions (N, Z, P) assigned with linguistic variables are used to fuzzify physical quantities. For inputs e(k) and e0(k) we have (e.n, e.z, e.p) and (e0.n, e0.z, e0.p). For the output u(k), we have (o.n, o.z, o.p). The fuzzified inputs are inferred to a fuzzy rule base, which is used to characterize the relationship between fuzzy inputs and fuzzy outputs. In this study, the fuzzy rule base of the fuzzy logic controller is fixed. It consists of the following nine fuzzy rules: 1. If e(k)=N and e0(k)=P then u(k)=Z. 2. If e(k)=Z and e0(k)=P then u(k)=P. 3. If e(k)=P and e0(k)=P then u(k)=P. 4. If e(k)=N and e0(k)=Z then u(k)=N. 5. If e(k)=N and e0(k)=N then u(k)=N. 6. If e(k)=P and e0(k)=Z then u(k)=P. 7. If e(k)=Z and e0(k)=N then u(k)=N. The response of each fuzzy rule is weighted according to the degree of membership of its input conditions. The inference engine provides a set of control actions according to fuzzified inputs. The commonly used inference engine is the MAX-MIN method and the centroid method is used for the defuzzification process.
  • 5. Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Inductionโ€ฆ DOI: 10.9790/1676-10620715 www.iosrjournals.org 11 | Page IV. Results And Simulation Simulation was applied on MATLAB/Simulink to the proposed fuzzy controller for the PWM VSI. The PI controller is selected for comparison because of its severe use in industry applications. The motor used in the simulation was a 5.5 kW squirrel cage motor with 400 V rated voltage, 12.5 A rated current and 1430 r/min rated speed. The PWM VSI was running with a switching frequency of 20 kHz. 4.1 Open Loop Response At Normal Condition: At normal and healthy condition i.e. when there is no fault in the inverter circuit, the current and voltage remain unchanged for it is the flux component of the stator current. The speed and torque are also continuous with time as motor is running smoothly. These all simulation results are shown below. It changes only when faults occur. So the current distortion is used to detect the occurrence of faults. When a fault occurs, both the current and voltage change abnormally and show repetitive waveforms. They distort at faulty stages where the faulty power switches make a vital influence and return to normal at healthy stages where the faulty power switches make a negligible influence. (1-a) (1-b) (1-c)
  • 6. Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Inductionโ€ฆ DOI: 10.9790/1676-10620715 www.iosrjournals.org 12 | Page (1-d) Fig.6. Simulation results in normal condition without fault: (1-a) Motor speed; (1-b) Output current;(1-c) Output voltage; (1-d) Load torque. 4.2 Open Loop Response At Faulty Condition: When the fault occurs in the VSI circuit, step change is introduced in switching pulse and the other parameters get disturbed wiz. Speed of the motor decreases and continues at low speed till the fault isnโ€™t isolated. In case of current and voltage the waveforms gets distorted means the waveforms shows repetitive distortions until the fault isolation. The torque also changes at the instant of fault occurrence then continues to normal. (2-a) (2-b)
  • 7. Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Inductionโ€ฆ DOI: 10.9790/1676-10620715 www.iosrjournals.org 13 | Page (2-c) (2-d) Fig.7. Simulation results in normal condition without fault: (2-a) Motor speed; (2-b) Output current; (2-c) Output voltage; (2-d) Load torque. 4.3 Closed Loop Response With Fuzzy Logic Controller: In order to overcome above results due to fault a fuzzy logic controller is used. With the help of this controller fault is isolated and the motor runs in normal condition. This is observed in below simulational results. As the fuzzy logic controller is more improved than a conventional PI controller, it gives the accurate and results. (3-a)
  • 8. Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Inductionโ€ฆ DOI: 10.9790/1676-10620715 www.iosrjournals.org 14 | Page (3-b) (3-c) ` (3-d) Fig.8. Simulation results in normal condition without fault: (3-a) Motor speed; (3-b) Output current; (3-c) Output voltage; (3-d) Load torque. V. Conclusion This paper has presented Fault Isolation in PWM Voltage-Source Inverters for Vector controlled Induction Motor Drives using Fuzzy logic controller. Simulation results are obtained showing a good agreement with the theoretical analysis. This method uses just as inputs the three-phase currents which are already available for the main control system, avoiding the use of extra sensors and the subsequent increase of the system complexity and costs. Comparing with previously published methods, the original method relies on the stage conversion. An open-circuit fault of power switches in the VSI changes the corresponding phase currents and introduces the periodic current distortions. When the fault occurs, the distortions are estimated. In order to overcome these estimated distortions, the fuzzy logic controller is used in the circuit. This controller shows the
  • 9. Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Inductionโ€ฆ DOI: 10.9790/1676-10620715 www.iosrjournals.org 15 | Page more accuracy than the conventional PI controller. Moreover, this method can be embedded into the existing vector-controlled induction motor drive software as a subsystem without excessive complications. The Basic circuit and modified circuit elements are designed using relevant equations. The simulation circuits are developed using elements of simulink library. The Simulation is successfully done and open loop / closed loop simulation results are presented. The Simulation results coincide with the theoretical results. References [1] Jianghan Zhang, Jin Zhao, Dehong Zhou, and Chengguang Huang, High-Performance Fault Diagnosis in PWM Voltage-Source Inverters for Vector-Controlled Induction Motor Drives, IEEE Transactions On Power Electronics, Vol. 29, No. 11, November 2014. [2] R. L. D. Ribeiro, C. B. Jacobina, E. R. C. da Silva, and A. M. N. Lima, Fault detection of open-switch damage in voltage-fed PWM motor drive systems, IEEE Trans. Power Electron., vol. 18, no. 2, Mar- 2003, 587โ€“593. [3] B. Lu and S. Sharma, A survey of IGBT fault diagnostic methods for three-phase power inverters, in Proc. 2008 Int. Conf. Condition Monitoring Diagnosis, 2007, 756โ€“763. [4] B. Lu and S. K. Sharma, A literature review of IGBT fault diagnostic and protection methods for power inverters, IEEE Trans. Ind. Appl., vol. 45, no. 5, Sep./Oct. 2009, 1770โ€“1777. [5] P. Gilreath and B. N. Singh, A new centroid based fault detection method for 3-phase inverter-fed induction motors, in Proc. 2005 IEEE 36th Power Electron. Spec. Conf., vol. 1โ€“3, 2005, 2664โ€“2669. [6] R. Peuget, S. Courtine, and J. P. Rognon, Fault detection and isolation on a PWM inverter by knowledge- based model, IEEE Trans. Ind. Appl., vol. 34, no. 6, Nov./Dec. 1998, 1318โ€“1326. [7] M. Trabelsi, M. Boussak, and A. Chaari, High performance single and multiple faults diagnosis in voltage source inverter fed induction motor drives, in Proc. 2012 XXth Int. Conf. Elect. Mach., 2012, 1717โ€“1723. [8] A. M. S. Mendes and A. J. M. Cardoso, Voltage source inverter fault diagnosis in variable speed AC drives, by the average current Parkโ€™s vector approach, in Proc. Int. Conf. Elect. Machines Drives, 1999, 704 โ€“ 706. [9] F. Zidani, D. Diallo, M. E. H. Benbouzid, and R. Nait-Said, A fuzzybased approach for the diagnosis of fault modes in a voltage-fed PWM inverter induction motor drive, IEEE Trans. Ind. Electron., vol. 55, no. 2, Feb. 2008, 586โ€“593. [10] N. M. A. Freire, J. O. Estima, and A. J. M. Cardoso, A voltage-based approach for open-circuit fault diagnosis in voltage-fed SVM motor drives without extra hardware, in Proc. 2012 XXth Int. Conf. Elect. Mach., 2012, 2378โ€“2383. [11] C. Delpha, C. Hao, and D. Diallo, SVM based diagnosis of inverter fed induction machine drive: A new challenge, in Proc. 38th Annu. Conf. IEEE Ind. Electron. Soc., 2012, 3931โ€“3936. [12] S. M. Jung, J. S. Park, H. W. Kim, K. Y. Cho, and M. J. Youn, An MRAS based diagnosis of open-circuit fault in PWM voltage source inverters for PM synchronous motor drive systems, IEEE Trans. Power Electron., vol. 28, no. 5, May 2013, 2514โ€“2526.