SlideShare a Scribd company logo
1 of 110
UNIT IV
POWER FROM RENEWABLE ENERGY
Hydro Electric Power Plants – Classification, Typical
Layout and associated components including
Turbines. Principle, Construction and working of
Wind, Tidal, Solar Photo Voltaic (SPV), Solar Thermal,
Geo Thermal, Biogas and Fuel Cell power systems.
Hydro Electric Power Plants
Hydro Electric
Converts Hydraulic Energy to Electrical Energy
• The water falls through a certain height, its
potential energy is converted into kinetic energy
and this kinetic energy is converted to the
mechanical energy by allowing the water to flow
through the hydraulic turbine runner. This
mechanical energy is utilized to run an electric
generator which is coupled to the turbine shaft.
Power Calculation
Site Selection
• Water Available
• Water-Storage
• Head of Water
• Distance from Load Center
• Access to Site
Classification
The hydro-power plants can be classified as below:
1. Storage plant
(a) High head plants
(b) Low head plants
(c) Medium head plants.
2. Run-of-river power plants
(a) With pondage
(b) Without pondage.
3. Pumped storage power Plants.
Layout of Hydro Electric Power Plant
Components of Hydro Electric Power
Plant
1) Dam The dam is the most important
component of hydroelectric power plant. The
dam is built on a large river that has
abundant quantity of water throughout the
year. It should be built at a location where
the height of the river is sufficient to get the
maximum possible potential energy from
water.
2) Water Reservoir The water reservoir is the
place behind the dam where water is stored.
The water in the reservoir is located higher
than the rest of the dam structure. The
height of water in the reservoir decides how
much potential energy the water possesses.
The higher the height of water, the more its
potential energy. The high position of water
in the reservoir also enables it to move
downwards effortlessly. The height of water
in the reservoir is higher than the natural
height of water flowing in the river, so it is
considered to have an altered equilibrium.
This also helps to increase the overall
potential energy of water, which helps
ultimately produce more electricity in the
power generation unit.
3) Intake or Control Gates These are the
gates built on the inside of the dam. The
water from reservoir is released and
controlled through these gates. These are
called inlet gates because water enters the
power generation unit through these
gates. When the control gates are opened
the water flows due to gravity through the
penstock and towards the turbines. The
water flowing through the gates possesses
potential as well as kinetic energy.
4) The Penstock The penstock is the long
pipe or the shaft that carries the water
flowing from the reservoir towards the
power generation unit, comprised of the
turbines and generator. The water in the
penstock possesses kinetic energy due to
its motion and potential energy due to its
height. The total amount of power
generated in the hydroelectric power
plant depends on the height of the water
reservoir and the amount of water flowing
through the penstock. The amount of
water flowing through the penstock is
controlled by the control gates.
5) Water Turbines Water flowing from the penstock is
allowed to enter the power generation unit, which houses
the turbine and the generator. When water falls on the
blades of the turbine the kinetic and potential energy of
water is converted into the rotational motion of the blades
of the turbine. The rotating blades causes the shaft of the
turbine to also rotate. The turbine shaft is enclosed inside
the generator. In most hydroelectric power plants there is
more than one power generation unit. There is large
difference in height between the level of turbine and level
of water in the reservoir. This difference in height, also
known as the head of water, decides the total amount of
power that can be generated in the hydroelectric power
plant. There are various types of water turbines such as
Kaplan turbine, Francis turbine, Pelton wheels etc. The type
of turbine used in the hydroelectric power plant depends
on the height of the reservoir, quantity of water and the
total power generation capacity
6) Generators It is in the generator where the electricity is
produced. The shaft of the water turbine rotates in the
generator, which produces alternating current in the coils of
the generator. It is the rotation of the shaft inside the
generator that produces magnetic field which is converted
into electricity by electromagnetic field induction. Hence
the rotation of the shaft of the turbine is crucial for the
production of electricity and this is achieved by the kinetic
and potential energy of water. Thus in hydroelectricity
power plants potential energy of water is converted into
electricity.
Wind Energy
Renewable Electric Capacity
Worldwide
Wind Turbine Operates
Theoretical Power Generated by Wind Turbine
Power = ½ (ρ)(A)(V)3
A = swept area = (radius)2
, m2
V = Wind Velocity, m/sec.
ρ = Density of air
Components of Wind Turbine
• Components:
• Rotor- The hub and the blades together are referred to as
the rotor. Wind turns the blades which turn the drive shaft.
• Shaft- Two different shafts turn the generator. One is used
for low speeds while another is used in high speeds.
• Gear Box- Gears connect the high and low speed shafts and
increase the rotational speeds from about 10-60 rotations
per minute to about 1200-1800 rpm, the rotational speed
required by most generators to produce power.
• Generator- The generator is what converts the turning
motion of a wind turbine's blades into electricity.
• Tower- Tall tubular metal shaft. The taller the tower, the
more power produced.
components
• Storage :
storage systems are used to store energy
when there is excess power developed and to
discharge it when there is a lack in power.
• Energy convertors
Usually, the electricity produced from wind energy is
direct current. Using alternator convert it to AC
before supply to power grid
Turbines: Two Types
• Horizontal Axis Wind Turbines
• Vertical Axis Wind Turbines
Advantages and Disadvantages
• Vertical Axis Advantages
– Can place generator on
ground
– You don’t need a yaw
mechanism for wind
angle
• Disadvantages
– Lower wind speeds at
ground level
– Less efficiency
• Horizontal Advantages
– Higher wind speeds
– Great efficiency
• Disadvantages
– Angle of blade is
relevant
– Difficult access to
generator for repairs
Types of wind mills
TIDAL ENERGY
How tides form?
• Mainly tides are produced by gravitational
attraction of the moon and sun on the water
of earth.
• 70% of the tide produces force due to moon
• 30%of the tide produces force due to sun
Tidal Energy
• It is a form of hydro power that converts the
energy of tides into useful form of power ,
mainly electricity. It is only form of energy
whose source is moon
Energy generated from tides
E= 5.04 h2 kJ
Where h = tide amplitude
Components of Tidal Barrage power
plants
Ebb generation
Flood generation
Two way generation
TIDAL POWER PLANT
1. Single Basin Arrangement
•Low Tide
•High Tide
2. Double Basin Arrangement
Single basin Arrangement
Double basin Arrangement
Site selection
• It should be nearer to the ocean
• It should be protected from the high ways
• It should not hamper shipping traffic
Solar Photovoltaic (PV)
A photovoltaic system, also solar PV power system, or PV
system, is a power system designed to supply usable solar
power by means of photovoltaic. It consists of an
arrangement of several components, including solar
panels to absorb and convert sunlight into electricity
PV SYSTEM
• Energy conversion devices which are used to
convert sunlight into electricity by the use of
the photovoltaic effect are called solar cells
• A single converter cell is called a solar cell,
more generally a photovoltaic cell and
combination of such cells are designed to
increase the electric power output called solar
module or solar array.
Basics of Semi conductor
• A semi conductor is an element with electrical
properties between those of a conductor and
insulator
• A best semiconductor has 4 valance electrons
• Example: Silicon
• If an electron attracted by the nucleus, extra
energy is needed to lift electrons to the higher
energy level are light , heat and voltage
Photo voltaic effect
• Whenever a heat and light energy fall on the
photovoltaic cell it induce movement of the
electrons and holes. This will generate the
potential difference. This effect is called photo
voltaic effect.
• Current depends upon the light intensity
because absorption of more light results in
additional electron flow.
Photo voltaic Materials
• Single crystalline Si cells
• Poly crystalline Si cells
• Amorphous Si cells
• Cadmium telluride
• Copper – Indium Selenide
• Nano crystalline solar cell
Solar Photovoltaic (PV)
Solar PV power generation systems
• Solar array
• Blocking Diode
Without a blocking diode, the battery would discharge back through the solar
array at the time of no isolation.
• Battery storage
• Inverter/Converter
• Switches and circuit breakers
Types of solar PV power generation
system
• Standalone power system
• Grid connected system
• Hybrid system
Standalone power system
Central system or grid connected
system
Hybrid system
Solar thermal power systems
• A solar collector is a device used for collecting
the solar radiation and it transfer the energy
to fluid passing in contact with it.
• Flat type solar collector
• Focusing type solar collector
Factors affecting the Solar system
efficiency
• Shadow effect
• Cosine loss factor
• Reflective loss factor
Solar Thermal Vs Solar PV
Flat plate collectors
• They are generally in rectangular type panels
about 1.7 to 2.9 m2
• They are relatively simple to construct and
erect.
1.Liquid heating collectors
2.Air heating collectors
3.Evacuated tubular collector
Liquid heating collectors
Modified flat plate collector
Solar air heaters
• Applications of solar water heater
Heating green house buildings
Drying agricultural products
Air-conditioning buildings
Heat source for heat engine
Evacuated tubular collector
Solar focusing collector or
Concentrating collector
• Main difference between flat type and
concentrating collector is that flat plate
collector only concentrates only direct
radiation but concentrating collector collect all
the incident radiation
Parabolic collector
Mirror strip reflector
Fresnel lens collector
Compound parabolic concentrator
Power generation using flat plate
collector
Power generation using solar
distributed collector
Power generation using central
receiver system
Geothermal Energy
Working of Geothermal Power Plant
Geothermal Energy
Geothermal power is an alternative source of energy that
harnesses the Earth’s heat in order to generate electricity. In
locations with shallow ground water at high temperatures,
wells are drilled in order to extract the steam or hot water.
There are three types of geothermal energy generation plants
•Dry Steam Power Plant
•Flash Power Plant
•Binary Power Plant
Dry Steam Power Plant
Flash Steam Power Plant
The heated water is sprayed into a tank held at much lower pressure than the
fluid. This causes the fluid to vaporize rapidly, or “flash.” The vapor then drives a
turbine to run the generator.
Binary Power Plant
Application of Geothermal Energy
Space Heating Air Conditioning Drying
Hot Water
Greenhouses
Aquaculture
ADVANTAGES
Environment friendly.
Renewable energy source.
High potential.
Low operational cost.
More reliable than other alternatives.
DIS ADVANTAGES
High installation cost .
May release harmful gases
.
Earthquakes .
Transportation .
BIO GAS
What is biogas?
• A mixture of methane and
carbon dioxide
CH4
CO2 • Methane or ‘swamp gas’,
produced naturally in
swampy ponds
Aerobic and Anaerobic Digestion
Biogas
plants
Conventi
onal
Domed
shape
Floating
type
Modern
Nisargruna
biogas
77
• A fixed-dome plant comprises of a closed,
dome-shaped digester with an
immovable, rigid gas-holder and a
displacement pit, also named
'compensation tank'.
• When gas production starts, the slurry is
displaced into the compensation tank.
• Gas pressure increases with the volume
of gas stored. 78
79
• Relatively low construction costs.
• The absence of moving parts and rusting
steel parts.
• If well constructed, fixed dome plants have
a long life span.
• The underground construction saves
space and protects the digester from
temperature changes.
• The construction provides opportunities for
80
• Fluctuating gas pressure complicates gas
utilization.
• Amount of gas produced is not
immediately visible.
• Fixed dome plants need exact planning of
levels.
• Excavation can be difficult and expensive
in bedrock.
81
• A floating-drum plant consists of a
cylindrical or dome-shaped digester and a
moving, floating gas-holder, or drum.
• The gas-holder floats either directly in the
fermenting slurry or in a separate water
jacket.
• The drum in which the biogas collects has
an internal and/or external guide frame that
provides stability and keeps the drum
upright. 82
83
• Floating-drum plants are easy to
understand and operate.
• They provide gas at a constant pressure.
• The stored gas-volume is immediately
recognizable by the position of the drum.
• Gas-tightness is no problem, provided the
gasholder is de-rusted and painted regularly.
84
• The steel drum is relatively expensive and
maintenance-intensive.
• Removing rust and painting has to be
carried out regularly.
• The life-time of the drum is short (up to 15
years; in tropical coastal regions about five
years).
• If fibrous substrates are used, the gas-
holder shows a tendency to get "stuck" in
85
• Updraft Gasifier
• Downdraft Gasifier
Fuel Cells: Components and Functions
• MEA = membrane
electrode assembly
(electrolyte and
electrodes)
• Anode = fuel electrode;
electronic conductor and
catalyst
• Cathode = air electrode;
electronic conductor and
catalyst
• Electrolyte = oxygen-ion
conductor, electron
inhibitor
Parts of a Fuel Cell
• Anode
– Negative post of the fuel cell.
– Conducts the electrons that are freed from the hydrogen molecules so that they
can be used in an external circuit.
– Etched channels disperse hydrogen gas over the surface of catalyst.
• Cathode
– Positive post of the fuel cell
– Etched channels distribute oxygen to the surface of the catalyst.
– Conducts electrons back from the external circuit to the catalyst
– Recombine with the hydrogen ions and oxygen to form water.
• Electrolyte
– Proton exchange membrane.
– Specially treated material, only conducts positively charged ions.
– Membrane blocks electrons.
• Catalyst
– Special material that facilitates reaction of oxygen and hydrogen
– Usually platinum powder very thinly coated onto carbon paper or cloth.
– Rough & porous maximizes surface area exposed to hydrogen or oxygen
– The platinum-coated side of the catalyst faces the PEM.
Fuel Cell Operation
• Pressurized hydrogen gas (H2) enters cell on anode side.
• Gas is forced through catalyst by pressure.
– When H2 molecule comes contacts platinum catalyst, it splits into two
H+ ions and two electrons (e-).
• Electrons are conducted through the anode
– Make their way through the external circuit (doing useful work such as
turning a motor) and return to the cathode side of the fuel cell.
• On the cathode side, oxygen gas (O2) is forced through the
catalyst
– Forms two oxygen atoms, each with a strong negative charge.
– Negative charge attracts the two H+ ions through the membrane,
– Combine with an oxygen atom and two electrons from the external
circuit to form a water molecule (H2O).
Proton-Exchange Membrane Cell
http://www.news.cornell.edu/releases/Nov03/Fuelcell.institute.deb.html
Fuel Cells: Types
– Electrolyte Types
• Alkaline
• Polymer Electrolyte Membrane (Proton Exchange
Membrane)
• Direct Methanol
• Phosphoric Acid
• Molten Carbonate
• Solid Oxide
Alkaline Fuel Cell
• First AFC developed by Francis Bacon (1930s)
• In the Apollo missions
– 85% KOH
– 200-230oC
– Ni anode and NiO cathode
– Acidic fuel cells had been used, but alkaline had faster oxygen
reduction kinetics
– Fuel cells were used to provide electricity, cool the ship, and
provide potable water
35%
KOH
O2
H2
H2O
OH-
Alkaline Fuel Cell
Anode: C/Pt or
C/Raney Ni/Pt
Cathode: C/Pt
H2 + 2OH-  H2O + 2e-
O2 + H2O + 2e-  HO2
- + OH-
HO2
- + H2O + 2e- 3OH-
1 A/cm2 at 0.7 V
r.t.-80oC
Alkaline Fuel Cell
 Advantages:
Low cost electrolyte solution (KOH 30-35%)
Non-noble catalyst withstand basic conditions
O2 kinetics faster in alkaline solution
Polymer Electrolyte Membrane Fuel Cell
• Used by NASA in Gemini mission
– employed polystyrene sulfonate (PSS) polymer (unstable)
• Nafion – developed by Dupont (1960s)
– Currently used in most PEMs
– Polytetrafluoroethylene (PTFE) backbone with a perfluorinated side chain
that is terminated with a sulfonic acid group
– More stable, higher conductivity
• The Dow Chemical Company
– Developed a polymer similar to Nafion
• Shorter side chain and only one ether oxygen
• No longer available
Polymer Electrolyte Membrane Fuel Cell
H2  2H+ + 2e- O2 + 2H+ + 2e-  H2O2
H2O2 + 2H+ + 2e-  H2O
Anode: C/Pt Cathode: C/Pt
N A F I O N
1 A/cm2 at 0.7 V
85-105oC
H2 O2
H+
H2O
Polymer Electrolyte Membrane Fuel Cell
• Advantages:
– Nonvolatile membrane
– CO2 rejecting electrolyte
– few material problems
Direct Methanol Fuel Cell
Anode: Pt/Ru/C Cathode: Pt/C
CH3OH + H2O CO2 + 6H+ + 6e-
O2 + 2H+ + 2e-  H2O2
H2O2 + 2H+ + 2e-  H2O
N
A
F
I
O
N
85-105oC
400 mA/cm2 at 0.5V
at 60oC
Direct Methanol Membrane Fuel Cell
• Advantages:
– Direct fuel conversion – no reformer needed, all positive aspects of
PEMFC
– CH3OH – natural gas or biomass
– Existing infastructure for transporting petrol can be converted to MeOH
• Problems:
– High catalyst loading (1-3mg/cm2 v. 0.1-0.3 mg/cm2)
– CH3OH hazardous
– Low efficiency (MeOH crossover – lowers potential)
Phosphoric Acid Fuel Cell
• Most commercially developed fuel cell
– Mainly used in stationary power plants
– More than 500 PAFC have been installed and tested around the
world
– Most influential developers of PAFC
• UTC Fuel Cells, Toshiba, and Fuji Electric
Phosphoric Acid Fuel Cell
Anode: Pt/C Cathode: Pt/C
H2 – 2e- = 2H+ O2 + 4H+ + 4e-  2H2O
200oC
100%
H2PO4
Si matrix
separator
PTFE binding
CH4 or H2 O2
H+
H2O
Phosphoric Acid Fuel Cell
• Advantages:
– H2O rejecting electrolyte
– high temps favor H2O2 decomposition
• O2 + H2O +2e-  H2O2
• Stable H2O2 lowers cell voltage and corrodes electrode
• Problems:
– O2 kinetic hindered
– CO catalyst poison at anode
– H2 only suitable fuel
– low conducting electrolyte
Molten Carbonate Fuel Carbonate
• Developed in the mid-20th century
• Developed because all carbonaceous fuel produce
CO2
• Using CO3
2- electrolyte eliminates need to regulate
CO3
2- build up
Molten Carbonate Fuel Carbonate
Anode: Ni/Al or Ni/Cr Cathode: NiO
CH4 + 2H2O  4H2 + CO2 + 4e-
H2 +CO3
2-  H2O + CO2 + 2e-
O2 + 2CO2 + 4e-  2CO3
2-
Li2CO3
and
Na2CO3
LiAlO3 used to
support
electrolyte
580-700oC
150 mA/cm2 at
0.8 V at 600oC
H2, CxH2x+2 O2, CO2
CO3
2-
Molten Carbonate Fuel Cell
• Advantages:
– Higher efficiency (v. PEMFC and PAFC) (50-70%)
– Internal reforming (H2 or CH4)
– No noble metal catalyst (High T increases O2 kinetics)
– No negative effects from CO or CO2
• Problems:
– Materials resistant to degradation at high T
• Ni, Fe, Co steel alloys better than SS
– NiO at cathode leeches into CO3
2- reducing efficiency or crossing
over causing short circuiting
• Dope electrode and electrolyte with Mg
• Kucera and Myles (LiFeO2 or Li2MnO3 stabilize)
Solid Oxide Fuel Cell
Cathode = La1-xSrxMnO3
Y doped
ZrO2
Anode = NiO-YSZ cermet 800-1000oC
H2 + O2-  H2O + 2e- OR
CH4 + 4O2-  2H2O + CO2 + 8e-
O2 + 2e-  2O2-
Interconnector
material = Mg
or Sr doped
lanthanum
chromate
1mA at 0.7V
H2, CxH2x+2 O2
O2-
Solid Oxide Fuel Cell
• Advantages:
– Solid electrolyte eliminates leaks
– H2O management, catalyst flooding, slow O2 kinetic are not
problematic
– CO and CO2 are not problematic
– Internal reforming - almost any hydrocarbon or hydrogen
fuel
• Problems:
– Severe material constraints due to high T
• Stainless steal at lower temperatures
• Alloyed metal or Lanthanum Chromite material
Applications
Fuel cells are being developed for application
in:
Stationary power plants
Automobiles
Portable electronics
To enable mobile power source, fuel must also
be portable

More Related Content

Similar to RES.pptx

hydroelectric power plant lesson for musa sharahili
hydroelectric power plant lesson for musa sharahilihydroelectric power plant lesson for musa sharahili
hydroelectric power plant lesson for musa sharahilimusa sharahili
 
Hydro power
Hydro powerHydro power
Hydro powerIbrahim R
 
Lesson 12 Energy Resources - Hydrothermal, Solar, and Wind Energy.pptx
Lesson 12 Energy Resources - Hydrothermal, Solar, and Wind Energy.pptxLesson 12 Energy Resources - Hydrothermal, Solar, and Wind Energy.pptx
Lesson 12 Energy Resources - Hydrothermal, Solar, and Wind Energy.pptxBerniceCayabyab1
 
Unit-4-POWER FROM RENEWABLE ENERGY.ppt
Unit-4-POWER FROM RENEWABLE ENERGY.pptUnit-4-POWER FROM RENEWABLE ENERGY.ppt
Unit-4-POWER FROM RENEWABLE ENERGY.pptdharma raja`
 
Hydro power plant
Hydro power plantHydro power plant
Hydro power plantAshvani Shukla
 
Hydro Energy or Hydro power conversion Technology
Hydro Energy or Hydro power conversion TechnologyHydro Energy or Hydro power conversion Technology
Hydro Energy or Hydro power conversion TechnologyTesfaye Birara
 
Unit 3 Generation and Distribution.pptx
Unit 3 Generation and Distribution.pptxUnit 3 Generation and Distribution.pptx
Unit 3 Generation and Distribution.pptxSHRIKANTNIKAM13
 
Hybrid wind-solar Power generation system
Hybrid wind-solar Power generation systemHybrid wind-solar Power generation system
Hybrid wind-solar Power generation systemShivam Joshi
 
hybws-161102114022.pdf
hybws-161102114022.pdfhybws-161102114022.pdf
hybws-161102114022.pdfGoneJustin
 
Introduction to power plant
Introduction to power plantIntroduction to power plant
Introduction to power plantRahul Rathod
 
Different power generatrion diagram and its breif explain by swapnil d
Different power generatrion  diagram and its breif explain by swapnil dDifferent power generatrion  diagram and its breif explain by swapnil d
Different power generatrion diagram and its breif explain by swapnil dSwapnil Dhage
 
Unit 5 Energy engg.ppsx
Unit 5 Energy engg.ppsxUnit 5 Energy engg.ppsx
Unit 5 Energy engg.ppsxMohsinAnsari73
 
Presentazione_energia_rinnovabile.ppt
Presentazione_energia_rinnovabile.pptPresentazione_energia_rinnovabile.ppt
Presentazione_energia_rinnovabile.pptTohidGanjiwale
 
NCES Wave Plant
NCES Wave PlantNCES Wave Plant
NCES Wave PlantVINOD MAKWANA
 
Hydroelectric_Power_Plant_-_presentation_-_II[1].ppt
Hydroelectric_Power_Plant_-_presentation_-_II[1].pptHydroelectric_Power_Plant_-_presentation_-_II[1].ppt
Hydroelectric_Power_Plant_-_presentation_-_II[1].pptsyedsulthanuddin5
 
Lecture 1
Lecture 1Lecture 1
Lecture 1Rohit Garg
 
Micro hydro power plant final 1
Micro hydro power plant final 1Micro hydro power plant final 1
Micro hydro power plant final 1richa khatri
 
l1intro to hydroelectric power
  l1intro to hydroelectric power  l1intro to hydroelectric power
l1intro to hydroelectric powerGhassan Hadi
 

Similar to RES.pptx (20)

hydroelectric power plant lesson for musa sharahili
hydroelectric power plant lesson for musa sharahilihydroelectric power plant lesson for musa sharahili
hydroelectric power plant lesson for musa sharahili
 
Hydro power
Hydro powerHydro power
Hydro power
 
Lesson 12 Energy Resources - Hydrothermal, Solar, and Wind Energy.pptx
Lesson 12 Energy Resources - Hydrothermal, Solar, and Wind Energy.pptxLesson 12 Energy Resources - Hydrothermal, Solar, and Wind Energy.pptx
Lesson 12 Energy Resources - Hydrothermal, Solar, and Wind Energy.pptx
 
Unit-4-POWER FROM RENEWABLE ENERGY.ppt
Unit-4-POWER FROM RENEWABLE ENERGY.pptUnit-4-POWER FROM RENEWABLE ENERGY.ppt
Unit-4-POWER FROM RENEWABLE ENERGY.ppt
 
Hydro power plant
Hydro power plantHydro power plant
Hydro power plant
 
Hydro Energy or Hydro power conversion Technology
Hydro Energy or Hydro power conversion TechnologyHydro Energy or Hydro power conversion Technology
Hydro Energy or Hydro power conversion Technology
 
Unit 3 Generation and Distribution.pptx
Unit 3 Generation and Distribution.pptxUnit 3 Generation and Distribution.pptx
Unit 3 Generation and Distribution.pptx
 
Hybrid wind-solar Power generation system
Hybrid wind-solar Power generation systemHybrid wind-solar Power generation system
Hybrid wind-solar Power generation system
 
hybws-161102114022.pdf
hybws-161102114022.pdfhybws-161102114022.pdf
hybws-161102114022.pdf
 
Introduction to power plant
Introduction to power plantIntroduction to power plant
Introduction to power plant
 
Different power generatrion diagram and its breif explain by swapnil d
Different power generatrion  diagram and its breif explain by swapnil dDifferent power generatrion  diagram and its breif explain by swapnil d
Different power generatrion diagram and its breif explain by swapnil d
 
Unit 5 Energy engg.ppsx
Unit 5 Energy engg.ppsxUnit 5 Energy engg.ppsx
Unit 5 Energy engg.ppsx
 
Hydraulic power plant
Hydraulic power plantHydraulic power plant
Hydraulic power plant
 
Presentazione_energia_rinnovabile.ppt
Presentazione_energia_rinnovabile.pptPresentazione_energia_rinnovabile.ppt
Presentazione_energia_rinnovabile.ppt
 
NCES Wave Plant
NCES Wave PlantNCES Wave Plant
NCES Wave Plant
 
OTEC
OTECOTEC
OTEC
 
Hydroelectric_Power_Plant_-_presentation_-_II[1].ppt
Hydroelectric_Power_Plant_-_presentation_-_II[1].pptHydroelectric_Power_Plant_-_presentation_-_II[1].ppt
Hydroelectric_Power_Plant_-_presentation_-_II[1].ppt
 
Lecture 1
Lecture 1Lecture 1
Lecture 1
 
Micro hydro power plant final 1
Micro hydro power plant final 1Micro hydro power plant final 1
Micro hydro power plant final 1
 
l1intro to hydroelectric power
  l1intro to hydroelectric power  l1intro to hydroelectric power
l1intro to hydroelectric power
 

Recently uploaded

Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxupamatechverse
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130Suhani Kapoor
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINESIVASHANKAR N
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝soniya singh
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escortsranjana rawat
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxwendy cai
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Serviceranjana rawat
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile servicerehmti665
 
Study on Air-Water & Water-Water Heat Exchange in a Finned ďťżTube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned ďťżTube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned ďťżTube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned ďťżTube ExchangerAnamika Sarkar
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxupamatechverse
 
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSCAESB
 
Analog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog ConverterAnalog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog ConverterAbhinavSharma374939
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSRajkumarAkumalla
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...Soham Mondal
 
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINEDJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINEslot gacor bisa pakai pulsa
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxpurnimasatapathy1234
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Dr.Costas Sachpazis
 
Internship report on mechanical engineering
Internship report on mechanical engineeringInternship report on mechanical engineering
Internship report on mechanical engineeringmalavadedarshan25
 

Recently uploaded (20)

Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptx
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptx
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile service
 
Study on Air-Water & Water-Water Heat Exchange in a Finned ďťżTube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned ďťżTube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned ďťżTube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned ďťżTube Exchanger
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptx
 
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentation
 
Analog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog ConverterAnalog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog Converter
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
 
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINEDJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptx
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 
Internship report on mechanical engineering
Internship report on mechanical engineeringInternship report on mechanical engineering
Internship report on mechanical engineering
 

RES.pptx

  • 1. UNIT IV POWER FROM RENEWABLE ENERGY Hydro Electric Power Plants – Classification, Typical Layout and associated components including Turbines. Principle, Construction and working of Wind, Tidal, Solar Photo Voltaic (SPV), Solar Thermal, Geo Thermal, Biogas and Fuel Cell power systems.
  • 3. Hydro Electric Converts Hydraulic Energy to Electrical Energy • The water falls through a certain height, its potential energy is converted into kinetic energy and this kinetic energy is converted to the mechanical energy by allowing the water to flow through the hydraulic turbine runner. This mechanical energy is utilized to run an electric generator which is coupled to the turbine shaft.
  • 5. Site Selection • Water Available • Water-Storage • Head of Water • Distance from Load Center • Access to Site
  • 6. Classification The hydro-power plants can be classified as below: 1. Storage plant (a) High head plants (b) Low head plants (c) Medium head plants. 2. Run-of-river power plants (a) With pondage (b) Without pondage. 3. Pumped storage power Plants.
  • 7. Layout of Hydro Electric Power Plant
  • 8. Components of Hydro Electric Power Plant
  • 9. 1) Dam The dam is the most important component of hydroelectric power plant. The dam is built on a large river that has abundant quantity of water throughout the year. It should be built at a location where the height of the river is sufficient to get the maximum possible potential energy from water. 2) Water Reservoir The water reservoir is the place behind the dam where water is stored. The water in the reservoir is located higher than the rest of the dam structure. The height of water in the reservoir decides how much potential energy the water possesses. The higher the height of water, the more its potential energy. The high position of water in the reservoir also enables it to move downwards effortlessly. The height of water in the reservoir is higher than the natural height of water flowing in the river, so it is considered to have an altered equilibrium. This also helps to increase the overall potential energy of water, which helps ultimately produce more electricity in the power generation unit.
  • 10. 3) Intake or Control Gates These are the gates built on the inside of the dam. The water from reservoir is released and controlled through these gates. These are called inlet gates because water enters the power generation unit through these gates. When the control gates are opened the water flows due to gravity through the penstock and towards the turbines. The water flowing through the gates possesses potential as well as kinetic energy. 4) The Penstock The penstock is the long pipe or the shaft that carries the water flowing from the reservoir towards the power generation unit, comprised of the turbines and generator. The water in the penstock possesses kinetic energy due to its motion and potential energy due to its height. The total amount of power generated in the hydroelectric power plant depends on the height of the water reservoir and the amount of water flowing through the penstock. The amount of water flowing through the penstock is controlled by the control gates.
  • 11. 5) Water Turbines Water flowing from the penstock is allowed to enter the power generation unit, which houses the turbine and the generator. When water falls on the blades of the turbine the kinetic and potential energy of water is converted into the rotational motion of the blades of the turbine. The rotating blades causes the shaft of the turbine to also rotate. The turbine shaft is enclosed inside the generator. In most hydroelectric power plants there is more than one power generation unit. There is large difference in height between the level of turbine and level of water in the reservoir. This difference in height, also known as the head of water, decides the total amount of power that can be generated in the hydroelectric power plant. There are various types of water turbines such as Kaplan turbine, Francis turbine, Pelton wheels etc. The type of turbine used in the hydroelectric power plant depends on the height of the reservoir, quantity of water and the total power generation capacity 6) Generators It is in the generator where the electricity is produced. The shaft of the water turbine rotates in the generator, which produces alternating current in the coils of the generator. It is the rotation of the shaft inside the generator that produces magnetic field which is converted into electricity by electromagnetic field induction. Hence the rotation of the shaft of the turbine is crucial for the production of electricity and this is achieved by the kinetic and potential energy of water. Thus in hydroelectricity power plants potential energy of water is converted into electricity.
  • 15. Theoretical Power Generated by Wind Turbine Power = ½ (ρ)(A)(V)3 A = swept area = (radius)2 , m2 V = Wind Velocity, m/sec. ρ = Density of air
  • 17. • Components: • Rotor- The hub and the blades together are referred to as the rotor. Wind turns the blades which turn the drive shaft. • Shaft- Two different shafts turn the generator. One is used for low speeds while another is used in high speeds. • Gear Box- Gears connect the high and low speed shafts and increase the rotational speeds from about 10-60 rotations per minute to about 1200-1800 rpm, the rotational speed required by most generators to produce power. • Generator- The generator is what converts the turning motion of a wind turbine's blades into electricity. • Tower- Tall tubular metal shaft. The taller the tower, the more power produced.
  • 18. components • Storage : storage systems are used to store energy when there is excess power developed and to discharge it when there is a lack in power. • Energy convertors Usually, the electricity produced from wind energy is direct current. Using alternator convert it to AC before supply to power grid
  • 19. Turbines: Two Types • Horizontal Axis Wind Turbines • Vertical Axis Wind Turbines
  • 20. Advantages and Disadvantages • Vertical Axis Advantages – Can place generator on ground – You don’t need a yaw mechanism for wind angle • Disadvantages – Lower wind speeds at ground level – Less efficiency • Horizontal Advantages – Higher wind speeds – Great efficiency • Disadvantages – Angle of blade is relevant – Difficult access to generator for repairs
  • 21. Types of wind mills
  • 23. How tides form? • Mainly tides are produced by gravitational attraction of the moon and sun on the water of earth. • 70% of the tide produces force due to moon • 30%of the tide produces force due to sun
  • 24. Tidal Energy • It is a form of hydro power that converts the energy of tides into useful form of power , mainly electricity. It is only form of energy whose source is moon
  • 25. Energy generated from tides E= 5.04 h2 kJ Where h = tide amplitude
  • 26. Components of Tidal Barrage power plants
  • 30. TIDAL POWER PLANT 1. Single Basin Arrangement •Low Tide •High Tide 2. Double Basin Arrangement
  • 33. Site selection • It should be nearer to the ocean • It should be protected from the high ways • It should not hamper shipping traffic
  • 34. Solar Photovoltaic (PV) A photovoltaic system, also solar PV power system, or PV system, is a power system designed to supply usable solar power by means of photovoltaic. It consists of an arrangement of several components, including solar panels to absorb and convert sunlight into electricity
  • 35. PV SYSTEM • Energy conversion devices which are used to convert sunlight into electricity by the use of the photovoltaic effect are called solar cells • A single converter cell is called a solar cell, more generally a photovoltaic cell and combination of such cells are designed to increase the electric power output called solar module or solar array.
  • 36. Basics of Semi conductor • A semi conductor is an element with electrical properties between those of a conductor and insulator • A best semiconductor has 4 valance electrons • Example: Silicon • If an electron attracted by the nucleus, extra energy is needed to lift electrons to the higher energy level are light , heat and voltage
  • 37. Photo voltaic effect • Whenever a heat and light energy fall on the photovoltaic cell it induce movement of the electrons and holes. This will generate the potential difference. This effect is called photo voltaic effect. • Current depends upon the light intensity because absorption of more light results in additional electron flow.
  • 38. Photo voltaic Materials • Single crystalline Si cells • Poly crystalline Si cells • Amorphous Si cells • Cadmium telluride • Copper – Indium Selenide • Nano crystalline solar cell
  • 40. Solar PV power generation systems • Solar array • Blocking Diode Without a blocking diode, the battery would discharge back through the solar array at the time of no isolation. • Battery storage • Inverter/Converter • Switches and circuit breakers
  • 41. Types of solar PV power generation system • Standalone power system • Grid connected system • Hybrid system
  • 43. Central system or grid connected system
  • 45. Solar thermal power systems • A solar collector is a device used for collecting the solar radiation and it transfer the energy to fluid passing in contact with it. • Flat type solar collector • Focusing type solar collector
  • 46. Factors affecting the Solar system efficiency • Shadow effect • Cosine loss factor • Reflective loss factor
  • 47. Solar Thermal Vs Solar PV
  • 48. Flat plate collectors • They are generally in rectangular type panels about 1.7 to 2.9 m2 • They are relatively simple to construct and erect. 1.Liquid heating collectors 2.Air heating collectors 3.Evacuated tubular collector
  • 50. Modified flat plate collector
  • 51. Solar air heaters • Applications of solar water heater Heating green house buildings Drying agricultural products Air-conditioning buildings Heat source for heat engine
  • 53. Solar focusing collector or Concentrating collector • Main difference between flat type and concentrating collector is that flat plate collector only concentrates only direct radiation but concentrating collector collect all the incident radiation
  • 58. Power generation using flat plate collector
  • 59. Power generation using solar distributed collector
  • 60. Power generation using central receiver system
  • 62. Working of Geothermal Power Plant
  • 63. Geothermal Energy Geothermal power is an alternative source of energy that harnesses the Earth’s heat in order to generate electricity. In locations with shallow ground water at high temperatures, wells are drilled in order to extract the steam or hot water. There are three types of geothermal energy generation plants •Dry Steam Power Plant •Flash Power Plant •Binary Power Plant
  • 65. Flash Steam Power Plant The heated water is sprayed into a tank held at much lower pressure than the fluid. This causes the fluid to vaporize rapidly, or “flash.” The vapor then drives a turbine to run the generator.
  • 67. Application of Geothermal Energy Space Heating Air Conditioning Drying Hot Water Greenhouses Aquaculture
  • 68. ADVANTAGES Environment friendly. Renewable energy source. High potential. Low operational cost. More reliable than other alternatives.
  • 69. DIS ADVANTAGES High installation cost . May release harmful gases . Earthquakes . Transportation .
  • 71. What is biogas? • A mixture of methane and carbon dioxide CH4 CO2 • Methane or ‘swamp gas’, produced naturally in swampy ponds
  • 72.
  • 73.
  • 74.
  • 76.
  • 78. • A fixed-dome plant comprises of a closed, dome-shaped digester with an immovable, rigid gas-holder and a displacement pit, also named 'compensation tank'. • When gas production starts, the slurry is displaced into the compensation tank. • Gas pressure increases with the volume of gas stored. 78
  • 79. 79
  • 80. • Relatively low construction costs. • The absence of moving parts and rusting steel parts. • If well constructed, fixed dome plants have a long life span. • The underground construction saves space and protects the digester from temperature changes. • The construction provides opportunities for 80
  • 81. • Fluctuating gas pressure complicates gas utilization. • Amount of gas produced is not immediately visible. • Fixed dome plants need exact planning of levels. • Excavation can be difficult and expensive in bedrock. 81
  • 82. • A floating-drum plant consists of a cylindrical or dome-shaped digester and a moving, floating gas-holder, or drum. • The gas-holder floats either directly in the fermenting slurry or in a separate water jacket. • The drum in which the biogas collects has an internal and/or external guide frame that provides stability and keeps the drum upright. 82
  • 83. 83
  • 84. • Floating-drum plants are easy to understand and operate. • They provide gas at a constant pressure. • The stored gas-volume is immediately recognizable by the position of the drum. • Gas-tightness is no problem, provided the gasholder is de-rusted and painted regularly. 84
  • 85. • The steel drum is relatively expensive and maintenance-intensive. • Removing rust and painting has to be carried out regularly. • The life-time of the drum is short (up to 15 years; in tropical coastal regions about five years). • If fibrous substrates are used, the gas- holder shows a tendency to get "stuck" in 85
  • 88.
  • 89. Fuel Cells: Components and Functions • MEA = membrane electrode assembly (electrolyte and electrodes) • Anode = fuel electrode; electronic conductor and catalyst • Cathode = air electrode; electronic conductor and catalyst • Electrolyte = oxygen-ion conductor, electron inhibitor
  • 90. Parts of a Fuel Cell • Anode – Negative post of the fuel cell. – Conducts the electrons that are freed from the hydrogen molecules so that they can be used in an external circuit. – Etched channels disperse hydrogen gas over the surface of catalyst. • Cathode – Positive post of the fuel cell – Etched channels distribute oxygen to the surface of the catalyst. – Conducts electrons back from the external circuit to the catalyst – Recombine with the hydrogen ions and oxygen to form water. • Electrolyte – Proton exchange membrane. – Specially treated material, only conducts positively charged ions. – Membrane blocks electrons. • Catalyst – Special material that facilitates reaction of oxygen and hydrogen – Usually platinum powder very thinly coated onto carbon paper or cloth. – Rough & porous maximizes surface area exposed to hydrogen or oxygen – The platinum-coated side of the catalyst faces the PEM.
  • 91. Fuel Cell Operation • Pressurized hydrogen gas (H2) enters cell on anode side. • Gas is forced through catalyst by pressure. – When H2 molecule comes contacts platinum catalyst, it splits into two H+ ions and two electrons (e-). • Electrons are conducted through the anode – Make their way through the external circuit (doing useful work such as turning a motor) and return to the cathode side of the fuel cell. • On the cathode side, oxygen gas (O2) is forced through the catalyst – Forms two oxygen atoms, each with a strong negative charge. – Negative charge attracts the two H+ ions through the membrane, – Combine with an oxygen atom and two electrons from the external circuit to form a water molecule (H2O).
  • 93. Fuel Cells: Types – Electrolyte Types • Alkaline • Polymer Electrolyte Membrane (Proton Exchange Membrane) • Direct Methanol • Phosphoric Acid • Molten Carbonate • Solid Oxide
  • 94. Alkaline Fuel Cell • First AFC developed by Francis Bacon (1930s) • In the Apollo missions – 85% KOH – 200-230oC – Ni anode and NiO cathode – Acidic fuel cells had been used, but alkaline had faster oxygen reduction kinetics – Fuel cells were used to provide electricity, cool the ship, and provide potable water
  • 95. 35% KOH O2 H2 H2O OH- Alkaline Fuel Cell Anode: C/Pt or C/Raney Ni/Pt Cathode: C/Pt H2 + 2OH-  H2O + 2e- O2 + H2O + 2e-  HO2 - + OH- HO2 - + H2O + 2e- 3OH- 1 A/cm2 at 0.7 V r.t.-80oC
  • 96. Alkaline Fuel Cell  Advantages: Low cost electrolyte solution (KOH 30-35%) Non-noble catalyst withstand basic conditions O2 kinetics faster in alkaline solution
  • 97. Polymer Electrolyte Membrane Fuel Cell • Used by NASA in Gemini mission – employed polystyrene sulfonate (PSS) polymer (unstable) • Nafion – developed by Dupont (1960s) – Currently used in most PEMs – Polytetrafluoroethylene (PTFE) backbone with a perfluorinated side chain that is terminated with a sulfonic acid group – More stable, higher conductivity • The Dow Chemical Company – Developed a polymer similar to Nafion • Shorter side chain and only one ether oxygen • No longer available
  • 98. Polymer Electrolyte Membrane Fuel Cell H2  2H+ + 2e- O2 + 2H+ + 2e-  H2O2 H2O2 + 2H+ + 2e-  H2O Anode: C/Pt Cathode: C/Pt N A F I O N 1 A/cm2 at 0.7 V 85-105oC H2 O2 H+ H2O
  • 99. Polymer Electrolyte Membrane Fuel Cell • Advantages: – Nonvolatile membrane – CO2 rejecting electrolyte – few material problems
  • 100. Direct Methanol Fuel Cell Anode: Pt/Ru/C Cathode: Pt/C CH3OH + H2O CO2 + 6H+ + 6e- O2 + 2H+ + 2e-  H2O2 H2O2 + 2H+ + 2e-  H2O N A F I O N 85-105oC 400 mA/cm2 at 0.5V at 60oC
  • 101. Direct Methanol Membrane Fuel Cell • Advantages: – Direct fuel conversion – no reformer needed, all positive aspects of PEMFC – CH3OH – natural gas or biomass – Existing infastructure for transporting petrol can be converted to MeOH • Problems: – High catalyst loading (1-3mg/cm2 v. 0.1-0.3 mg/cm2) – CH3OH hazardous – Low efficiency (MeOH crossover – lowers potential)
  • 102. Phosphoric Acid Fuel Cell • Most commercially developed fuel cell – Mainly used in stationary power plants – More than 500 PAFC have been installed and tested around the world – Most influential developers of PAFC • UTC Fuel Cells, Toshiba, and Fuji Electric
  • 103. Phosphoric Acid Fuel Cell Anode: Pt/C Cathode: Pt/C H2 – 2e- = 2H+ O2 + 4H+ + 4e-  2H2O 200oC 100% H2PO4 Si matrix separator PTFE binding CH4 or H2 O2 H+ H2O
  • 104. Phosphoric Acid Fuel Cell • Advantages: – H2O rejecting electrolyte – high temps favor H2O2 decomposition • O2 + H2O +2e-  H2O2 • Stable H2O2 lowers cell voltage and corrodes electrode • Problems: – O2 kinetic hindered – CO catalyst poison at anode – H2 only suitable fuel – low conducting electrolyte
  • 105. Molten Carbonate Fuel Carbonate • Developed in the mid-20th century • Developed because all carbonaceous fuel produce CO2 • Using CO3 2- electrolyte eliminates need to regulate CO3 2- build up
  • 106. Molten Carbonate Fuel Carbonate Anode: Ni/Al or Ni/Cr Cathode: NiO CH4 + 2H2O  4H2 + CO2 + 4e- H2 +CO3 2-  H2O + CO2 + 2e- O2 + 2CO2 + 4e-  2CO3 2- Li2CO3 and Na2CO3 LiAlO3 used to support electrolyte 580-700oC 150 mA/cm2 at 0.8 V at 600oC H2, CxH2x+2 O2, CO2 CO3 2-
  • 107. Molten Carbonate Fuel Cell • Advantages: – Higher efficiency (v. PEMFC and PAFC) (50-70%) – Internal reforming (H2 or CH4) – No noble metal catalyst (High T increases O2 kinetics) – No negative effects from CO or CO2 • Problems: – Materials resistant to degradation at high T • Ni, Fe, Co steel alloys better than SS – NiO at cathode leeches into CO3 2- reducing efficiency or crossing over causing short circuiting • Dope electrode and electrolyte with Mg • Kucera and Myles (LiFeO2 or Li2MnO3 stabilize)
  • 108. Solid Oxide Fuel Cell Cathode = La1-xSrxMnO3 Y doped ZrO2 Anode = NiO-YSZ cermet 800-1000oC H2 + O2-  H2O + 2e- OR CH4 + 4O2-  2H2O + CO2 + 8e- O2 + 2e-  2O2- Interconnector material = Mg or Sr doped lanthanum chromate 1mA at 0.7V H2, CxH2x+2 O2 O2-
  • 109. Solid Oxide Fuel Cell • Advantages: – Solid electrolyte eliminates leaks – H2O management, catalyst flooding, slow O2 kinetic are not problematic – CO and CO2 are not problematic – Internal reforming - almost any hydrocarbon or hydrogen fuel • Problems: – Severe material constraints due to high T • Stainless steal at lower temperatures • Alloyed metal or Lanthanum Chromite material
  • 110. Applications Fuel cells are being developed for application in: Stationary power plants Automobiles Portable electronics To enable mobile power source, fuel must also be portable