Current Problem
No simple system exists to measure forces exerted on crane rails
Forces are currently only analyzed through theory
Very difficult to accurately predict lateral and vertical forces hence
support designs may be inadequate
1. Quality on Track®
A Member of the GANTRY GROUP
Rail Load Measurement Services
Current Problem:
No simple system exists to measure forces exerted on crane rails
Forces are currently only analyzed through theory
Very difficult to accurately predict lateral and vertical forces hence
support designs may be inadequate
Gantrex Solution:
A simple and economical solution to measure the forces generated
by the crane operation
Measurements of the lateral and vertical forces exerted on the rail
Provides a Force Histogram graph of lateral forces for analysis,
and pressure maping of vertical load (if required)
Track Expertise
Temporary Installation of Gantrex measuring device:
• Fast and easy to install on site, usually 1-2 hours
• that doesn’t require any handling of the rail while it is measuring
Load measurements are obtained autonomously without operation
interference, or personnel risk.
Main Characteristics
ased on the new RailLok™ range.
B
easurement accuracy: +/- 5%
M
ange of the lateral forces measured: from 0 to 300 kN
R
ervice currently available to measure the following rails:
S
• A75, A100, A120, A150, MRS 87A, MRS 125, 104CR,
135CR, 175CR and 171CR, (other rails request)
Track Geometry
easuring device is compact and low profile; Suitable for
M
narrow beams and crane’s with guide rollers)
For more information,
contact your local
Gantrex representative
Waterproof system
Can work autonomously for 24 hours
GANTREX Inc. / GANTREX CANADA Inc.
www.Gantrex.com
sales@Gantrex.com
2. Rail Load Measurement Services
Measurement procedure
dentify the most stressed areas of the track
I
n case of continuous mounting:
I
• Weld a RailLok lower part on a beam/plate
n case of discontinuous mounting
I
• Install an intermediate chair plate under the rail
ount the measuring clip on the lower part
M
nstall the measuring device (data logger, battery, cables
I
included in the compact portable case)
ecord the data
R
Post-process the data and provide a clear
measurement report
Data processing
(source: test performed on a discontinuous mounting site)
(1) Vertical forces:
The maximum vertical forces are measured using
sensitive paper
(2) Lateral forces:
The lateral forces are shown on a force histogram
Lateral Forces: Loaded Rack
5000
4500
Rue du commerce, 19
B-1400, Nivelles
T: +32(0)67.88.80.30
F: +32(0)67.21.63.21
info@be.gantry.com
www.gantrex.be
4000
3500
3000
2500
2000
1500
1000
50
0
0
10
Contact GANTREX:
20
30
40
Ph: 1-800-242-6873
50
60
70
Web: www.Gantrex.com
E-Mail: sales@Gantrex.com