SlideShare a Scribd company logo
1 of 96
Download to read offline
Beginning Vibration
Analysis
with
Basic Fundamentals
By: Jack Peters
Jack D. Peters
Beginning Vibration
2
Introduction
Understanding the basics and fundamentals of vibration analysis are
very important in forming a solid background to analyze problems on
rotating machinery.
Switching between time and frequency is a common tool used for
analysis. Because the frequency spectrum is derived from the data in
the time domain, the relationship between time and frequency is very
important. Units of acceleration, velocity, and displacement are
typical. Additional terms such as peak-peak, peak, and rms. are often
used. Switching units correctly, and keeping terms straight is a must.
As much as possible, this training will follow the criteria as established
by the Vibration Institute.
Jack D. Peters
Mass & Stiffness
3
Mass & Stiffness
All machines can be broken down
into two specific categories.
Mass & Stiffness
Mass is represented by an object
that wants to move or rotate.
Stiffness is represented by springs
or constraints of that movement.
Jack D. Peters
Mass & Stiffness
4
Mass & Stiffness
fn = 1/2П k/m
Where:
fn = natural frequency (Hz)
k = stiffness (lb/in)
m = mass
mass = weight/gravity
weight (lb)
gravity (386.1 in/sec2)
Jack D. Peters
Mass & Stiffness
5
Concept !
fn = 1/2П k/m
If k increases
Then f increases
If k decreases
Then f decreases
Jack D. Peters
Mass & Stiffness
6
Concept !
fn = 1/2П k/m
If m increases
Then f decreases
If m decreases
Then f increases
Jack D. Peters
Spectrum
7
What’s This ?
0.0002
inch
Peak
0
Magnitude
Hz1000 Hz
1
Jack D. Peters
Spectrum
8
FFT, Frequency Spectrum, Power Spectrum
0.0002
inch
Peak
0
Magnitude
Hz1000 Hz
1
Jack D. Peters
Spectrum
9
Scaling X & Y
0.0002
inch
Peak
0
Magnitude
Hz1000 Hz
1
X
Y
Jack D. Peters
Spectrum
10
Scaling X & Y
0.0002
inch
Peak
0
Magnitude
Hz1000 Hz
1
FREQUENCY
A
M
P
L
I
T
U
D
E
Jack D. Peters
Spectrum
11
Scaling X & Y
0.0002
inch
Peak
0
Magnitude
Hz1000 Hz
1
What is it
H
o
w
B
a
d
I
s
I
t
Jack D. Peters
Time Waveform
12
What’s That ?
0.0004
inch
-0.0004
Real
s7.9960940 s
1
Jack D. Peters
Time Waveform
13
Time Waveform
0.0004
inch
-0.0004
Real
s7.9960940 s
1
Jack D. Peters
Time Waveform
14
Scaling X & Y
X
Y
0.0004
inch
-0.0004
Real
s7.9960940 s
1
Jack D. Peters
Time Waveform
15
Scaling X & Y
TIME
A
M
P
L
I
T
U
D
E
0.0004
inch
-0.0004
Real
s7.9960940 s
1
Jack D. Peters
Time Waveform
16
Scaling X & Y
What is it
H
o
w
B
a
d
I
s
I
t
0.0004
inch
-0.0004
Real
s7.9960940 s
1
Jack D. Peters
Time Waveform
17
Scaling X & Y
What is it
H
o
w
B
a
d
I
s
I
t
0.0004
inch
-0.0004
Real
s10 s
1
Jack D. Peters
Time & Frequency
18
Double Trouble
0.0004
inch
-0.0004
Real
s7.9960940 s
1
0.0002
inch
Peak
0
Magnitude
Hz1000 Hz
1
Jack D. Peters
The X Scale
19
The X Scale
Jack D. Peters
The X Scale
20
Hertz (Hz)
One Hertz (Hz) is equal to 1 cycle / second
It is the most common term used in vibration
analysis to describe the frequency of a disturbance.
Never forget the 1 cycle / second relationship !
Traditional vibration analysis quite often expresses
frequency in terms of cycle / minute (cpm). This is
because many pieces of process equipment have
running speeds related to revolutions / minute (rpm).
60 cpm = 1 cps = 1 Hz
Jack D. Peters
The X Scale
21
Relationship with Time
The frequency domain is an expression of amplitude
and individual frequencies.
A single frequency can be related to time.
F(Hz) = 1 / T(s)
The inverse of this is also true for a single frequency.
T(s) = 1 / F(Hz)
Keep in mind that the time domain is an expression
of amplitude and multiple frequencies.
Jack D. Peters
The X Scale
22
Concept !
If: F = 1/T and T = 1/F
Then: FT = 1
Jack D. Peters
The X Scale
23
Concept !
FT = 1
If: F increases
Then: T decreases
If: T increases
Then: F decreases
Jack D. Peters
The X Scale
24
Single Frequency
1
V
rms
0
Magnitude
Hz1000 Hz
Pwr Spec 1
1
V
-1
Real
ms62.469480 s
Time 1
X:55 Hz Y:706.8129 mV
dX:18.18848 ms dY:2.449082 mV
X:27.00806 ms Y:3.579427 mV
Jack D. Peters
The X Scale
25
Multiple Frequencies
1
Hz1000 Hz
Pwr Spec 1
1
Hz1000 Hz
Pwr Spec 1
1
Hz1000 Hz
Pwr Spec 1
1
Hz1000 Hz
Pwr Spec 1
X:55 Hz Y:706.8129 mV
X:78 Hz Y:706.9236 mV
X:21 Hz Y:706.7825 mV
X:42 Hz Y:706.9266 mV
Jack D. Peters
The X Scale
26
Multiple Time
1
V
ms62.469480 s
Time 78 1
1
V
ms62.469480 s
Time 21 1
1
V
ms62.469480 s
Time 42 1
1
V
ms62.469480 s
Time 55 1
Jack D. Peters
The X Scale
27
Real Life Time
4
V
-4
Real
ms62.469480 s
TIME 1
55 + 78 + 21 + 42 = Trouble !
Jack D. Peters
The X Scale
28
Frequency Spectrum
4
V
-4
Real
ms62.469480 s
TIME 1
1
V
rms
Hz1000 Hz
FREQUENCY 1
X:78 Hz Y:706.9236 mV
X:55 Hz Y:706.8129 mV
X:42 Hz Y:706.9266 mV
X:21 Hz Y:706.7825 mV
Jack D. Peters
The X Scale
29
The Most Copied Slide in the History of Vibration Analysis !
Amplitude
Input Time Frequency
Time Waveform Spectrum
Jack D. Peters
The X Scale
30
Lines of Resolution
0.0002
inch
Peak
0
Magnitude
Hz1000 Hz
1
The FFT always
has a defined
number of lines
of resolution.
100, 200, 400,
800, 1600, and
3200 lines are
common
choices.
This spectrum
has 800 lines, or
the X scale is
broken down into
800 points.
Jack D. Peters
The X Scale
31
Filter Windows
• Window filters are applied to the time
waveform data to simulate data that
starts and stops at zero.
• They will cause errors in the time
waveform and frequency spectrum.
• We still like window filters !
Jack D. Peters
The X Scale
32
Window Comparisons
Jack D. Peters
The X Scale
33
Filter Windows
• Hanning (Frequency)
• Flat Top (Amplitude)
• Uniform (No Window)
• Force Exponential
• Force/Expo Set-up
(Frequency Response)
Hanning 16% Amplitude Error
Flat Top 1% Amplitude Error
Window functions courtesy of Agilent
“The Fundamentals of Signal Analysis”
Application Note #AN 243
Jack D. Peters
The X Scale
34
Filter Windows
• Use the Hanning Window for normal
vibration monitoring (Frequency)
• Use the Flat Top Window for calibration
and accuracy (Amplitude)
• Use the Uniform Window for bump
testing and resonance checks (No
Window)
Jack D. Peters
The X Scale
35
Minimum Derived Hz
The minimum derived frequency is determined by:
Frequency Span / Number of Analyzer Lines (data points)
The frequency span is calculated as the ending
frequency minus the starting frequency.
The number of analyzer lines depends on the analyzer
and how the operator has set it up.
Example: 0 - 400 Hz using 800 lines
Answer = (400 - 0) / 800 = 0.5 Hz / Line
Jack D. Peters
The X Scale
36
Bandwidth
The Bandwidth can be defined by:
(Frequency Span / Analyzer Lines) Window Function
Uniform Window Function = 1.0
Hanning Window Function = 1.5
Flat Top Window Function = 3.5
Example: 0 - 400 Hz using 800 Lines & Hanning Window
Answer = (400 / 800) 1.5 = 0.75 Hz / Line
Note: More discussion
later on window functions
for the analyzer !
Jack D. Peters
The X Scale
37
Resolution
The frequency resolution is defined in the following
manner:
2 (Frequency Span / Analyzer Lines) Window Function
or
Resolution = 2 (Bandwidth)
Example: 0 - 400 Hz using 800 Lines & Hanning Window
Answer = 2 (400 / 800) 1.5 = 1.5 Hz / Line
Jack D. Peters
The X Scale
38
Using Resolution
The student wishes to measure two frequency
disturbances that are very close together.
Frequency #1 = 29.5 Hz.
Frequency #2 = 30 Hz.
The instructor suggests a hanning window and 800 lines.
What frequency span is required to accurately measure
these two frequency disturbances ?
Jack D. Peters
The X Scale
39
Using Resolution
Resolution = 30 - 29.5 = 0.5 Hz / Line
Resolution = 2 (Bandwidth)
BW = (Frequency Span / Analyzer Lines) Window Function
Resolution = 2 (Frequency Span / 800) 1.5
0.5 = 2 (Frequency Span / 800) 1.5
0.5 = 3 (Frequency Span) / 800
400 = 3 (Frequency Span)
133 Hz = Frequency Span
Jack D. Peters
The X Scale
40
Data Sampling Time
Data sampling time is the amount of time required to take
one record or sample of data. It is dependent on the
frequency span and the number of analyzer lines being used.
TSample = Nlines / Fspan
Using 400 lines with a 800 Hz frequency span will require:
400 / 800 = 0.5 seconds
Jack D. Peters
The X Scale
41
Average & Overlap
• Average - On
• Overlap Percent - 50%
TR#1 TR#2 TR#3
FFT#1 FFT#2 FFT#3
TR#1
TR#2
TR#3
FFT#1
FFT#2
FFT#3
0% Overlap
50% Overlap
How long will it take for 10
averages at 75% overlap
using a 800 line analyzer and
a 200 Hz frequency span?
Jack D. Peters
The X Scale
42
75% Overlap ?
• 10 Averages
• 75% Overlap
• 800 Lines
• 200 Hz
Average #1 = 800 / 200
Average #1 = 4 seconds
Average #2 - #10 = (4 x 0.25)
Average #2 - #10 = 1 second
each
Total time = 4 + (1 x 9)
Total time = 13 seconds
Jack D. Peters
The Y Scale
43
The Y Scale
Jack D. Peters
The Y Scale
44
Amplitude
The “Y” scale provides the amplitude value for each
signal or frequency.
Default units for the “Y” scale are volts RMS.
Volts is an Engineering Unit (EU).
RMS is one of three suffixes meant to confuse you !
The other two are:
(Peak) and (Peak - Peak)
Jack D. Peters
The Y Scale
45
Pk-Pk (Peak - Peak)
1
V
-1
Real
ms62.469480 s
Time 1
2
V
Pk-Pk
0
Magnitude
Hz1000 Hz
Pwr Spec 1
dX:9.094238 ms dY:1.994871 V
X:22.43042 ms Y:-993.8563 mV
X:55 Hz Y:1.999169 V
The Peak - Peak value
is expressed from the
peak to peak amplitude.
The spectrum value
uses the suffix “Pk-Pk”
to denote this.
Jack D. Peters
The Y Scale
46
Pk (Peak)
1
V
-1
Real
ms62.469480 s
Time 1
1
V
Peak
0
Magnitude
Hz1000 Hz
Pwr Spec 1
dX:4.516602 ms dY:997.4356 mV
X:27.00806 ms Y:3.579427 mV
X:55 Hz Y:999.5843 mVThe time wave has not
changed. The Peak
value is expressed
from zero to the peak
amplitude.
The spectrum value
uses the suffix “Peak”
to denote this.
Jack D. Peters
The Y Scale
47
RMS (Root Mean Square)
1
V
rms
0
Magnitude
Hz1000 Hz
Pwr Spec 1
1
V
-1
Real
ms62.469480 s
Time 1
X:55 Hz Y:706.8129 mV
dX:2.288818 ms dY:709.1976 mV
X:27.00806 ms Y:3.579427 mV
The time wave has
not changed. The
RMS value is
expressed from zero
to 70.7% of the peak
amplitude.
The spectrum value
uses the suffix
“RMS” to denote this.
Jack D. Peters
The Y Scale
48
Suffix Comparison
2
V
rms
0
Magnitude
Hz1000 Hz
Pwr Spec 1
2
V
Peak
0
Magnitude
Hz1000 Hz
Pwr Spec 1
2
V
Pk-Pk
0
Magnitude
Hz1000 Hz
Pwr Spec 1
1
V
-1
Real
ms62.469480 s
Time 1
1
V
-1
Real
ms62.469480 s
Time 1
1
V
-1
Real
ms62.469480 s
Time 1
X:55 Hz Y:706.8129 mV
X:55 Hz Y:999.5843 mV
X:55 Hz Y:1.999169 V
dX:2.288818 ms dY:709.1976 m
X:27.00806 ms Y:3.579427 mV
dX:4.516602 ms dY:997.4356 m
X:27.00806 ms Y:3.579427 mV
dX:9.094238 ms dY:1.994871 V
X:22.43042 ms Y:-993.8563 mV
RMS
Peak
Peak - Peak
Jack D. Peters
The Y Scale
49
Changing Suffixes
Many times it is necessary to change between suffixes.
Pk-Pk / 2 = Peak
Peak x 0.707 = RMS
RMS x 1.414 = Peak
Peak x 2 = Pk-Pk
Jack D. Peters
The Y Scale
50
Standard Suffixes
Now that we have learned all about the three
standard suffixes that might possibly confuse the
“Y” scale values, what is the standard ?
Vibration Institute:
Displacement = mils Peak - Peak
Velocity = in/s Peak or rms..
Acceleration = g’s Peak or rms..
Note: 1 mil = 0.001 inches
Jack D. Peters
The Y Scale
51
Engineering Units (EU)
Engineering units are used to give meaning to the
amplitude of the measurement.
Instead of the default “volts”, it is possible to incorporate
a unit proportional to volts that will have greater
meaning to the user.
Examples: 100 mV / g 20 mV / Pa
1 V / in/s 200 mV / mil
50 mV / psi 10 mV / fpm
33 mV / % 10 mV / V
Jack D. Peters
The Y Scale
52
EU’s the Hard Way
Sometimes we forget to use EU’s, or just don’t understand how
to set up the analyzer.
There is no immediate need to panic if ????
You know what the EU is for the sensor you are using.
Example: An accelerometer outputs 100 mV / g and there is a
10 mV peak in the frequency spectrum.
What is the amplitude in g’s ?
Answer = 10 mV / 100 mV = 0.1 g
Jack D. Peters
The Y Scale
53
The Big Three EU’s
Acceleration
Velocity
Displacement
Jack D. Peters
The Y Scale
54
Converting the Big 3
In many cases we are confronted with Acceleration,
Velocity, or Displacement, but are not happy with it.
Maybe we have taken the measurement in
acceleration, but the model calls for displacement.
Maybe we have taken the data in displacement, but
the manufacturer quoted the equipment
specifications in velocity.
How do we change between these EU’s ?
Jack D. Peters
The Y Scale
55
386.1 What ?
1g = 32.2 feet/second2
32.2 feet 12 inches
second2 X
foot
386.1 inches/second2
g
Jack D. Peters
The Y Scale
56
Go With The Flow I
Acceleration (g’s)
Velocity (inch/s)
Displacement (inch)
x 386.1
÷ 2(Pi)f
÷ 2(Pi)fx 2(Pi)f
x 2(Pi)f
÷ 386.1
Jack D. Peters
The Y Scale
57
Metric Go With The Flow I
Acceleration (g’s)
Velocity (mm/s)
Displacement (mm)
x 9807
÷ 2(Pi)f
÷ 2(Pi)fx 2(Pi)f
x 2(Pi)f
÷ 9807
Jack D. Peters
The Y Scale
58
Go With The Flow II
Peak - Peak
Peak
RMS
÷ 2
x .707x 1.414
x 2
Jack D. Peters
The Y Scale
59
Doing the Math Units
0.5g x 386.1 inches
second2
g
2π x 25 cycles
second
0.5g x 386.1 inches x 1 second
g second2
2π x 25 cycles
0.5 x 386.1 inches
2π x 25 cycles second
cycle
1.23 inches/second
There is a 0.5 g
vibration at 25 Hz.
What is the velocity ?
Jack D. Peters
The Y Scale
60
Acceleration - Velocity
Example: Find the equivalent peak velocity for a 25 Hz
vibration at 7 mg RMS ?
= (g x 386.1) / (2 Pi x F)
= (0.007 x 386.1) / (6.28 x 25)
= 0.017 inches / second RMS
Answer = 0.017 x 1.414 = 0.024 inches / second Pk
Jack D. Peters
The Y Scale
61
Velocity - Displacement
Example: Find the equivalent pk-pk displacement for a
25 Hz vibration at 0.024 in/s Pk ?
= Velocity / (2 Pi x F)
= 0.024 / (6.28 x 25)
= 0.000153 inches Pk
Answer = 0.000153 x 2 = 0.000306 inches Pk-Pk
Jack D. Peters
The Y Scale
62
Acceleration - Displacement
Example: Find the equivalent Pk-Pk displacement for a
52 Hz vibration at 15 mg RMS ?
= (g x 386.1) / (2 Pi x F)2
= (0.015 x 386.1) / (6.28 x 52)2
= 0.000054 inches RMS
Answer = (0.000054 x 1.414) 2 = 0.000154 inches Pk-Pk
Jack D. Peters
Sensors
63
Sensors
Jack D. Peters
Sensors
64
Accelerometers
• Integrated Circuit
Electronics inside
Industrial
• Charge Mode
Charge Amplifier
Test & Measurement
Jack D. Peters
Sensors
65
Accelerometer Advantages
• Measures casing vibration
• Measures absolute motion
• Can integrate to Velocity output
• Easy to mount
• Large range of frequency response
• Available in many configurations
Jack D. Peters
Sensors
66
Accelerometer Disadvantages
• Does not measure shaft vibration
• Sensitive to mounting techniques and
surface conditions
• Difficult to perform calibration check
• Double integration to displacement often
causes low frequency noise
• One accelerometer does not fit all
applications
Jack D. Peters
Sensors
67
Mass & Charge
Mass
Ceramic/Quartz
Post
Relative movement
between post &
mass creates shear
in ceramic
producing charge.
Jack D. Peters
Sensors
68
Accelerometer Parameters
Performance Suited for Application
Sensitivity (mV/g)
Frequency Response of target (f span)
Dynamic Range of target (g level)
Jack D. Peters
Sensors
69
Mounting the Accelerometer
500 2000 6,500 10,000 15,000 15,000
Hz.
Jack D. Peters
Sensors
70
Realistic Mounting
Stud
Bees Wax
Adhesive
Magnet
Hand Held
100 1,000 10,000
Frequency, Hz
In the real world,
mounting might
not be as good as
the manufacturer
had in the lab !
What happened
to the high
frequency ?
Jack D. Peters
Sensors
71
Mounting Location
Axial
Horizontal
Vertical
Load Zone
Radial
Vertical
Horizontal
Axial
Jack D. Peters
Sensors
72
Mounting Location
Load Zone
Radial
Vertical
Horizontal
Axial
Jack D. Peters
Sensors
73
Accelerometer Alarms
Machine Condition
rms peak
Acceptance of new or repaired equipment < 0.08 < 0.16
Unrestricted operation (normal) < 0.12 < 0.24
Surveillance 0.12 - 0.28 0.24 - 0.7
Unsuitable for Operation > 0.28 > 0.7
Velocity Limit
Note #1: The rms velocity (in/sec) is the band power or
band energy calculated in the frequency spectrum.
Note #2: The peak velocity (in/sec) is the largest positive
or negative peak measured in the time waveform.
Jack D. Peters
Sensors
74
Proximity Probes
Jack D. Peters
Sensors
75
Proximity Probe Theory
Driver
Target
Cable
Probe
The tip of the probe broadcasts a radio frequency signal
into the surrounding area as a magnetic field.
If a conductive target intercepts the magnetic field, eddy
currents are generated on the surface of the target, and
power is drained from the radio frequency signal.
As the power varies with target movement in the radio
frequency field, the output voltage of the driver also
varies.
A small dc voltage indicates that the target is close to the
probe tip.
A large dc voltage indicates that the target is far away
from the probe tip.
The variation of dc voltage is the dynamic signal
indicating the vibration or displacement.
Jack D. Peters
Sensors
76
Output Values
• Typical
– 100 mv/mil
– 200 mv/mil
• Depends on
probe, cable
(length), and
driver.
• Target material
varies output.
Calibration Examples
• Copper 380 mV/mil
• Aluminum 370 mV/mil
• Brass 330 mV/mil
• Tungsten Carbide 290 mV/mil
• Stainless Steel 250 mV/mil
• Steel 4140, 4340 200 mV/mil
Based on typical output sensitivity
of 200 mV/mil.
Jack D. Peters
Sensors
77
Proximity Probes - Advantages
• Non-contact
• Measure shaft dynamic motion
• Measure shaft static position (gap)
• Flat frequency response dc – 1KHz
• Simple calibration
• Suitable for harsh environments
Jack D. Peters
Sensors
78
Proximity Probes - Disadvantages
• Probe can move (vibrate)
• Doesn’t work on all metals
• Plated shafts may give false measurement
• Measures nicks & tool marks in shaft
• Must be replaced as a unit (probe, cable &
driver)
• Must have relief at sensing tip from
surrounding metal
Jack D. Peters
Sensors
79
Typical Mounting
vertical probe horizontal probe
H
V
time
Facing Driver to Driven
(independent of rotation)
Jack D. Peters
Sensors
80
Looking at Orbits
Vertical for
Amplitude
Horizontal for
Time Base
Jack D. Peters
Sensors
81
The Orbit Display
ils
Mils
Mils
Jack D. Peters
Sensors
82
Unbalance
Jack D. Peters
Sensors
83
Unbalance with Orbit
Jack D. Peters
Sensors
84
Misalignment
Jack D. Peters
Sensors
85
Misalignment with Orbit
Jack D. Peters
Sensors
86
And the problem is ?
Jack D. Peters
Sensors
87
Proximity Probe Alarms
Machine Condition
< 3,600 RPM < 10,000 RPM
Normal 0.3 0.2
Surveillance 0.3 - 0.5 0.2 - 0.4
Planned Shutdown 0.5 0.4
Unsuitable for Operation 0.7 0.6
Allowable R/C
Note #1: R is the relative displacement of the shaft
measured by either probe in mils peak-peak.
Note #2: C is the diametrical clearance (difference
between shaft OD and journal ID) measured in mils.
Jack D. Peters
Sensors
88
Analyzer Input - Front End
• Coupling - AC, DC
• Antialias Filter - On, Off
AC coupling will block the DC voltage.
It creates an amplitude error below 1
Hz. DC coupling has no error below 1
Hz, but the analyzer must range on the
total signal amplitude.
Prevents frequencies that are greater
than span from wrapping around in
the spectrum.
Analyzer Input Capacitor
Blocks DC
AC Coupling Capacitor in DSA
If the antialias filter is turned off, at what
frequency will 175 Hz. appear using a 0 -
100 Hz span, and 800 lines ?
1024/800 = 1.28
100 x 1.28 = 128 Hz
175 Hz - 128 Hz = 47 Hz.
128 Hz - 47 Hz = 81 Hz
Jack D. Peters
Sensors
89
Low End Frequency Response
0.01
V
rms
0.002
Magnitude
Hz250 Hz
Input 1
0.01
V
rms
0
Magnitude
Hz250 Hz
Output 2
2
0
Magnitude
Hz250 Hz
Freq Resp 2:1
1.1
0.9
Magnitude
Hz250 Hz
Coherence 2:1
X:2.8125 Hz Y:984.7542 m
X:500 mHz Y:720.0918 m
X:5.34375 Hz Y:1.000001
To the right is a typical
problem with frequency
response at the low end of
the frequency spectrum.
This low end roll off was a
result of AC coupling on
CH #2 of the analyzer.
Values below 2.8 Hz are in
error, and values less than
0.5 Hz should not be used.
Jack D. Peters
Data Collection
90
Data Collection
Jack D. Peters
Data Collection
91
Tape Recorders “Insurance Policy”
Multi-channel
digital audio tape
recorders.
For the
Measurement that
can’t get away !
Jack D. Peters
Data Collection
92
Dynamic Signal Analyzers “Test & Measurement”
Large PC driven solutions
with multiple channels and
windows based software.
Smaller portable units
with 2 – 4 channel
inputs and firmware
operating systems.
Jack D. Peters
Data Collection
93
Data Collectors “Rotating Equipment”
Jack D. Peters
Data Collection
94
Data Collectors “Rotating Equipment”
• Route Based
• Frequency
Spectrum
• Time Waveform
• Orbits
• Balancing
• Alignment
• Data Analysis
• History
• Trending
• Download to PC
• Alarms
• “Smart” algorithms
Jack D. Peters
Beginning Vibration
95
Bibliography
• Eisenmann, Robert Sr. & Eisenmann, Robert Jr., Machinery
Malfunction Diagnosis and Correction, ISBN 0-13-240946-1
• Eshleman, Ronald L., Basic Machinery Vibrations, ISBN 0-
9669500-0-3
• LaRocque, Thomas, Vibration Analysis Design, Selection,
Mounting, and Installation, Application Note, Connection
Technology Center
• Agilent Technologies, The Fundamentals of Signal Analysis,
Application note 243
• Agilent Technologies, Effective Machinery Measurements using
Dynamic Signal Analyzers, Application note 243-1
Jack D. Peters
Beginning Vibration
96
Thank You !
You can find technical papers on
this and other subjects at
www.ctconline.com
in the “Technical Resources” section

More Related Content

What's hot

Vibration analysis at thermal power plants
Vibration analysis at thermal power plantsVibration analysis at thermal power plants
Vibration analysis at thermal power plants
SHIVAJI CHOUDHURY
 

What's hot (20)

Rotating Equipment Vibration Analysis.pdf
Rotating Equipment Vibration Analysis.pdfRotating Equipment Vibration Analysis.pdf
Rotating Equipment Vibration Analysis.pdf
 
Vibration Analysis, Emerson Makes it Easy for You
Vibration Analysis, Emerson Makes it Easy for YouVibration Analysis, Emerson Makes it Easy for You
Vibration Analysis, Emerson Makes it Easy for You
 
Vibration Monitoring
Vibration MonitoringVibration Monitoring
Vibration Monitoring
 
Machine vibration analysis
Machine vibration analysisMachine vibration analysis
Machine vibration analysis
 
B. basic of vibration
B. basic of vibrationB. basic of vibration
B. basic of vibration
 
Measurement & Control of Vibration
Measurement & Control of VibrationMeasurement & Control of Vibration
Measurement & Control of Vibration
 
Vibration analysis unit1
Vibration analysis unit1Vibration analysis unit1
Vibration analysis unit1
 
Fluke Vibration Testing 101 Webinar
Fluke Vibration Testing 101 WebinarFluke Vibration Testing 101 Webinar
Fluke Vibration Testing 101 Webinar
 
Vibration analysis at thermal power plants
Vibration analysis at thermal power plantsVibration analysis at thermal power plants
Vibration analysis at thermal power plants
 
Mechanical looseness vibration(mechanical engineering ugm)
Mechanical looseness vibration(mechanical engineering ugm)Mechanical looseness vibration(mechanical engineering ugm)
Mechanical looseness vibration(mechanical engineering ugm)
 
1 vibration basics0
1 vibration basics01 vibration basics0
1 vibration basics0
 
Bent shaft vibration
Bent shaft vibrationBent shaft vibration
Bent shaft vibration
 
Condition monitoring &amp; vibration analysis
Condition monitoring &amp; vibration analysisCondition monitoring &amp; vibration analysis
Condition monitoring &amp; vibration analysis
 
Vibration measurement
Vibration measurement Vibration measurement
Vibration measurement
 
Vibration analysis to find out fault in machines
Vibration analysis to find out fault in machinesVibration analysis to find out fault in machines
Vibration analysis to find out fault in machines
 
Misalignment Vibration
Misalignment Vibration Misalignment Vibration
Misalignment Vibration
 
Motor Current Signature Analysis
Motor Current Signature AnalysisMotor Current Signature Analysis
Motor Current Signature Analysis
 
4. pelton turbine
4. pelton turbine4. pelton turbine
4. pelton turbine
 
Vibration and frequency measuring instruments
Vibration and frequency measuring instrumentsVibration and frequency measuring instruments
Vibration and frequency measuring instruments
 
ppt on induction generator
ppt on induction generatorppt on induction generator
ppt on induction generator
 

Viewers also liked

Shaft Alignment Trainer [SAT] presentation
Shaft Alignment Trainer [SAT] presentationShaft Alignment Trainer [SAT] presentation
Shaft Alignment Trainer [SAT] presentation
Spectra Quest Inc
 
Mechanical Vibrations all slides
Mechanical Vibrations all slidesMechanical Vibrations all slides
Mechanical Vibrations all slides
Ebrahim Hanash
 

Viewers also liked (20)

Mechanical Vibration- An introduction
Mechanical Vibration- An introductionMechanical Vibration- An introduction
Mechanical Vibration- An introduction
 
Beginners guide vibration
Beginners guide vibrationBeginners guide vibration
Beginners guide vibration
 
Bva apr-03 (1)
Bva apr-03 (1)Bva apr-03 (1)
Bva apr-03 (1)
 
Where should a keyphasor transducer be mounted?
Where should a keyphasor transducer be mounted?Where should a keyphasor transducer be mounted?
Where should a keyphasor transducer be mounted?
 
Br0094
Br0094Br0094
Br0094
 
fundamentals of vibrations Leonard meirovitch
 fundamentals of vibrations Leonard meirovitch fundamentals of vibrations Leonard meirovitch
fundamentals of vibrations Leonard meirovitch
 
Shaft Alignment Tolerances
Shaft Alignment TolerancesShaft Alignment Tolerances
Shaft Alignment Tolerances
 
188757055 1-alignment
188757055 1-alignment188757055 1-alignment
188757055 1-alignment
 
Prealignment
PrealignmentPrealignment
Prealignment
 
Advanced Maintenance Management
Advanced Maintenance ManagementAdvanced Maintenance Management
Advanced Maintenance Management
 
5.alignment
5.alignment5.alignment
5.alignment
 
Shaft Alignment Trainer [SAT] presentation
Shaft Alignment Trainer [SAT] presentationShaft Alignment Trainer [SAT] presentation
Shaft Alignment Trainer [SAT] presentation
 
Machinery Vibration Analysis and Maintenance
Machinery Vibration Analysis and Maintenance Machinery Vibration Analysis and Maintenance
Machinery Vibration Analysis and Maintenance
 
vibration
vibrationvibration
vibration
 
Mechanical Vibration
Mechanical VibrationMechanical Vibration
Mechanical Vibration
 
Mechanical Vibrations all slides
Mechanical Vibrations all slidesMechanical Vibrations all slides
Mechanical Vibrations all slides
 
01 beginning vibration analysis
01 beginning vibration analysis01 beginning vibration analysis
01 beginning vibration analysis
 
Vibration analysis
Vibration analysisVibration analysis
Vibration analysis
 
1 q05 ch_one-shotbalancing
1 q05 ch_one-shotbalancing1 q05 ch_one-shotbalancing
1 q05 ch_one-shotbalancing
 
Solutions for LNG facilities
Solutions for LNG facilitiesSolutions for LNG facilities
Solutions for LNG facilities
 

Similar to 01 beginning vibration analysis

1999 si pi_dws_training_course
1999 si pi_dws_training_course1999 si pi_dws_training_course
1999 si pi_dws_training_course
Piero Belforte
 
rffundamentalsseminarrecordingsection1v21588598809158.pdf
rffundamentalsseminarrecordingsection1v21588598809158.pdfrffundamentalsseminarrecordingsection1v21588598809158.pdf
rffundamentalsseminarrecordingsection1v21588598809158.pdf
santanusen30
 
Sleep 2008 Electronicsv.3
Sleep 2008 Electronicsv.3Sleep 2008 Electronicsv.3
Sleep 2008 Electronicsv.3
weckhardt
 
Slide Handouts with Notes
Slide Handouts with NotesSlide Handouts with Notes
Slide Handouts with Notes
Leon Nguyen
 
Tennessee State University College of Engineering, Tec.docx
Tennessee State University College of Engineering, Tec.docxTennessee State University College of Engineering, Tec.docx
Tennessee State University College of Engineering, Tec.docx
mehek4
 

Similar to 01 beginning vibration analysis (20)

RiseFalltime031114.pptx
RiseFalltime031114.pptxRiseFalltime031114.pptx
RiseFalltime031114.pptx
 
1999 si pi_dws_training_course
1999 si pi_dws_training_course1999 si pi_dws_training_course
1999 si pi_dws_training_course
 
Lectures on digital communication by prof.dr.a.abbas
Lectures on digital communication by prof.dr.a.abbasLectures on digital communication by prof.dr.a.abbas
Lectures on digital communication by prof.dr.a.abbas
 
Lectures on Digital Dommunication by Prof.Dr.A.Abbas Khan
Lectures on Digital Dommunication by Prof.Dr.A.Abbas KhanLectures on Digital Dommunication by Prof.Dr.A.Abbas Khan
Lectures on Digital Dommunication by Prof.Dr.A.Abbas Khan
 
Time-Frequency Representation of Microseismic Signals using the SST
Time-Frequency Representation of Microseismic Signals using the SSTTime-Frequency Representation of Microseismic Signals using the SST
Time-Frequency Representation of Microseismic Signals using the SST
 
equalization in digital communication.pdf
equalization in digital communication.pdfequalization in digital communication.pdf
equalization in digital communication.pdf
 
Spectral-, source-, connectivity- and network analysis of EEG and MEG data
Spectral-, source-, connectivity- and network analysis of EEG and MEG dataSpectral-, source-, connectivity- and network analysis of EEG and MEG data
Spectral-, source-, connectivity- and network analysis of EEG and MEG data
 
rffundamentalsseminarrecordingsection1v21588598809158.pdf
rffundamentalsseminarrecordingsection1v21588598809158.pdfrffundamentalsseminarrecordingsection1v21588598809158.pdf
rffundamentalsseminarrecordingsection1v21588598809158.pdf
 
Sleep 2008 Electronicsv.3
Sleep 2008 Electronicsv.3Sleep 2008 Electronicsv.3
Sleep 2008 Electronicsv.3
 
Radar 2009 a 3 review of signals systems and dsp
Radar 2009 a  3 review of signals systems and dspRadar 2009 a  3 review of signals systems and dsp
Radar 2009 a 3 review of signals systems and dsp
 
Radar 2009 a 3 review of signals, systems, and dsp
Radar 2009 a  3 review of signals, systems, and dspRadar 2009 a  3 review of signals, systems, and dsp
Radar 2009 a 3 review of signals, systems, and dsp
 
Radar 2009 a 3 review of signals, systems, and dsp
Radar 2009 a  3 review of signals, systems, and dspRadar 2009 a  3 review of signals, systems, and dsp
Radar 2009 a 3 review of signals, systems, and dsp
 
Signal Processing
Signal ProcessingSignal Processing
Signal Processing
 
Slide Handouts with Notes
Slide Handouts with NotesSlide Handouts with Notes
Slide Handouts with Notes
 
signal.ppt
signal.pptsignal.ppt
signal.ppt
 
4 Band Audio Equalizer Project
4 Band Audio Equalizer Project4 Band Audio Equalizer Project
4 Band Audio Equalizer Project
 
Doppler radar
Doppler radarDoppler radar
Doppler radar
 
Sampling
SamplingSampling
Sampling
 
Tennessee State University College of Engineering, Tec.docx
Tennessee State University College of Engineering, Tec.docxTennessee State University College of Engineering, Tec.docx
Tennessee State University College of Engineering, Tec.docx
 
Course-Notes__Advanced-DSP.pdf
Course-Notes__Advanced-DSP.pdfCourse-Notes__Advanced-DSP.pdf
Course-Notes__Advanced-DSP.pdf
 

More from Dương Phúc (6)

Gasket design criteria
Gasket design criteriaGasket design criteria
Gasket design criteria
 
Bearing dianogsis 1
Bearing dianogsis  1Bearing dianogsis  1
Bearing dianogsis 1
 
Vibration sensors 2012
Vibration sensors 2012Vibration sensors 2012
Vibration sensors 2012
 
Precdicting corrosion crack rates growth
Precdicting corrosion crack rates growthPrecdicting corrosion crack rates growth
Precdicting corrosion crack rates growth
 
Crankshaft fatigue
Crankshaft fatigueCrankshaft fatigue
Crankshaft fatigue
 
01 intro
01 intro01 intro
01 intro
 

Recently uploaded

Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Safe Software
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
?#DUbAI#??##{{(☎️+971_581248768%)**%*]'#abortion pills for sale in dubai@
 
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Victor Rentea
 

Recently uploaded (20)

AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
 
Artificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyArtificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : Uncertainty
 
FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024
 
Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
 
DEV meet-up UiPath Document Understanding May 7 2024 Amsterdam
DEV meet-up UiPath Document Understanding May 7 2024 AmsterdamDEV meet-up UiPath Document Understanding May 7 2024 Amsterdam
DEV meet-up UiPath Document Understanding May 7 2024 Amsterdam
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
Manulife - Insurer Transformation Award 2024
Manulife - Insurer Transformation Award 2024Manulife - Insurer Transformation Award 2024
Manulife - Insurer Transformation Award 2024
 
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
 
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdfRising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
 
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost SavingRepurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
 
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, AdobeApidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
 
ICT role in 21st century education and its challenges
ICT role in 21st century education and its challengesICT role in 21st century education and its challenges
ICT role in 21st century education and its challenges
 
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
 
Corporate and higher education May webinar.pptx
Corporate and higher education May webinar.pptxCorporate and higher education May webinar.pptx
Corporate and higher education May webinar.pptx
 
Spring Boot vs Quarkus the ultimate battle - DevoxxUK
Spring Boot vs Quarkus the ultimate battle - DevoxxUKSpring Boot vs Quarkus the ultimate battle - DevoxxUK
Spring Boot vs Quarkus the ultimate battle - DevoxxUK
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
Cyberprint. Dark Pink Apt Group [EN].pdf
Cyberprint. Dark Pink Apt Group [EN].pdfCyberprint. Dark Pink Apt Group [EN].pdf
Cyberprint. Dark Pink Apt Group [EN].pdf
 

01 beginning vibration analysis

  • 2. Jack D. Peters Beginning Vibration 2 Introduction Understanding the basics and fundamentals of vibration analysis are very important in forming a solid background to analyze problems on rotating machinery. Switching between time and frequency is a common tool used for analysis. Because the frequency spectrum is derived from the data in the time domain, the relationship between time and frequency is very important. Units of acceleration, velocity, and displacement are typical. Additional terms such as peak-peak, peak, and rms. are often used. Switching units correctly, and keeping terms straight is a must. As much as possible, this training will follow the criteria as established by the Vibration Institute.
  • 3. Jack D. Peters Mass & Stiffness 3 Mass & Stiffness All machines can be broken down into two specific categories. Mass & Stiffness Mass is represented by an object that wants to move or rotate. Stiffness is represented by springs or constraints of that movement.
  • 4. Jack D. Peters Mass & Stiffness 4 Mass & Stiffness fn = 1/2П k/m Where: fn = natural frequency (Hz) k = stiffness (lb/in) m = mass mass = weight/gravity weight (lb) gravity (386.1 in/sec2)
  • 5. Jack D. Peters Mass & Stiffness 5 Concept ! fn = 1/2П k/m If k increases Then f increases If k decreases Then f decreases
  • 6. Jack D. Peters Mass & Stiffness 6 Concept ! fn = 1/2П k/m If m increases Then f decreases If m decreases Then f increases
  • 7. Jack D. Peters Spectrum 7 What’s This ? 0.0002 inch Peak 0 Magnitude Hz1000 Hz 1
  • 8. Jack D. Peters Spectrum 8 FFT, Frequency Spectrum, Power Spectrum 0.0002 inch Peak 0 Magnitude Hz1000 Hz 1
  • 9. Jack D. Peters Spectrum 9 Scaling X & Y 0.0002 inch Peak 0 Magnitude Hz1000 Hz 1 X Y
  • 10. Jack D. Peters Spectrum 10 Scaling X & Y 0.0002 inch Peak 0 Magnitude Hz1000 Hz 1 FREQUENCY A M P L I T U D E
  • 11. Jack D. Peters Spectrum 11 Scaling X & Y 0.0002 inch Peak 0 Magnitude Hz1000 Hz 1 What is it H o w B a d I s I t
  • 12. Jack D. Peters Time Waveform 12 What’s That ? 0.0004 inch -0.0004 Real s7.9960940 s 1
  • 13. Jack D. Peters Time Waveform 13 Time Waveform 0.0004 inch -0.0004 Real s7.9960940 s 1
  • 14. Jack D. Peters Time Waveform 14 Scaling X & Y X Y 0.0004 inch -0.0004 Real s7.9960940 s 1
  • 15. Jack D. Peters Time Waveform 15 Scaling X & Y TIME A M P L I T U D E 0.0004 inch -0.0004 Real s7.9960940 s 1
  • 16. Jack D. Peters Time Waveform 16 Scaling X & Y What is it H o w B a d I s I t 0.0004 inch -0.0004 Real s7.9960940 s 1
  • 17. Jack D. Peters Time Waveform 17 Scaling X & Y What is it H o w B a d I s I t 0.0004 inch -0.0004 Real s10 s 1
  • 18. Jack D. Peters Time & Frequency 18 Double Trouble 0.0004 inch -0.0004 Real s7.9960940 s 1 0.0002 inch Peak 0 Magnitude Hz1000 Hz 1
  • 19. Jack D. Peters The X Scale 19 The X Scale
  • 20. Jack D. Peters The X Scale 20 Hertz (Hz) One Hertz (Hz) is equal to 1 cycle / second It is the most common term used in vibration analysis to describe the frequency of a disturbance. Never forget the 1 cycle / second relationship ! Traditional vibration analysis quite often expresses frequency in terms of cycle / minute (cpm). This is because many pieces of process equipment have running speeds related to revolutions / minute (rpm). 60 cpm = 1 cps = 1 Hz
  • 21. Jack D. Peters The X Scale 21 Relationship with Time The frequency domain is an expression of amplitude and individual frequencies. A single frequency can be related to time. F(Hz) = 1 / T(s) The inverse of this is also true for a single frequency. T(s) = 1 / F(Hz) Keep in mind that the time domain is an expression of amplitude and multiple frequencies.
  • 22. Jack D. Peters The X Scale 22 Concept ! If: F = 1/T and T = 1/F Then: FT = 1
  • 23. Jack D. Peters The X Scale 23 Concept ! FT = 1 If: F increases Then: T decreases If: T increases Then: F decreases
  • 24. Jack D. Peters The X Scale 24 Single Frequency 1 V rms 0 Magnitude Hz1000 Hz Pwr Spec 1 1 V -1 Real ms62.469480 s Time 1 X:55 Hz Y:706.8129 mV dX:18.18848 ms dY:2.449082 mV X:27.00806 ms Y:3.579427 mV
  • 25. Jack D. Peters The X Scale 25 Multiple Frequencies 1 Hz1000 Hz Pwr Spec 1 1 Hz1000 Hz Pwr Spec 1 1 Hz1000 Hz Pwr Spec 1 1 Hz1000 Hz Pwr Spec 1 X:55 Hz Y:706.8129 mV X:78 Hz Y:706.9236 mV X:21 Hz Y:706.7825 mV X:42 Hz Y:706.9266 mV
  • 26. Jack D. Peters The X Scale 26 Multiple Time 1 V ms62.469480 s Time 78 1 1 V ms62.469480 s Time 21 1 1 V ms62.469480 s Time 42 1 1 V ms62.469480 s Time 55 1
  • 27. Jack D. Peters The X Scale 27 Real Life Time 4 V -4 Real ms62.469480 s TIME 1 55 + 78 + 21 + 42 = Trouble !
  • 28. Jack D. Peters The X Scale 28 Frequency Spectrum 4 V -4 Real ms62.469480 s TIME 1 1 V rms Hz1000 Hz FREQUENCY 1 X:78 Hz Y:706.9236 mV X:55 Hz Y:706.8129 mV X:42 Hz Y:706.9266 mV X:21 Hz Y:706.7825 mV
  • 29. Jack D. Peters The X Scale 29 The Most Copied Slide in the History of Vibration Analysis ! Amplitude Input Time Frequency Time Waveform Spectrum
  • 30. Jack D. Peters The X Scale 30 Lines of Resolution 0.0002 inch Peak 0 Magnitude Hz1000 Hz 1 The FFT always has a defined number of lines of resolution. 100, 200, 400, 800, 1600, and 3200 lines are common choices. This spectrum has 800 lines, or the X scale is broken down into 800 points.
  • 31. Jack D. Peters The X Scale 31 Filter Windows • Window filters are applied to the time waveform data to simulate data that starts and stops at zero. • They will cause errors in the time waveform and frequency spectrum. • We still like window filters !
  • 32. Jack D. Peters The X Scale 32 Window Comparisons
  • 33. Jack D. Peters The X Scale 33 Filter Windows • Hanning (Frequency) • Flat Top (Amplitude) • Uniform (No Window) • Force Exponential • Force/Expo Set-up (Frequency Response) Hanning 16% Amplitude Error Flat Top 1% Amplitude Error Window functions courtesy of Agilent “The Fundamentals of Signal Analysis” Application Note #AN 243
  • 34. Jack D. Peters The X Scale 34 Filter Windows • Use the Hanning Window for normal vibration monitoring (Frequency) • Use the Flat Top Window for calibration and accuracy (Amplitude) • Use the Uniform Window for bump testing and resonance checks (No Window)
  • 35. Jack D. Peters The X Scale 35 Minimum Derived Hz The minimum derived frequency is determined by: Frequency Span / Number of Analyzer Lines (data points) The frequency span is calculated as the ending frequency minus the starting frequency. The number of analyzer lines depends on the analyzer and how the operator has set it up. Example: 0 - 400 Hz using 800 lines Answer = (400 - 0) / 800 = 0.5 Hz / Line
  • 36. Jack D. Peters The X Scale 36 Bandwidth The Bandwidth can be defined by: (Frequency Span / Analyzer Lines) Window Function Uniform Window Function = 1.0 Hanning Window Function = 1.5 Flat Top Window Function = 3.5 Example: 0 - 400 Hz using 800 Lines & Hanning Window Answer = (400 / 800) 1.5 = 0.75 Hz / Line Note: More discussion later on window functions for the analyzer !
  • 37. Jack D. Peters The X Scale 37 Resolution The frequency resolution is defined in the following manner: 2 (Frequency Span / Analyzer Lines) Window Function or Resolution = 2 (Bandwidth) Example: 0 - 400 Hz using 800 Lines & Hanning Window Answer = 2 (400 / 800) 1.5 = 1.5 Hz / Line
  • 38. Jack D. Peters The X Scale 38 Using Resolution The student wishes to measure two frequency disturbances that are very close together. Frequency #1 = 29.5 Hz. Frequency #2 = 30 Hz. The instructor suggests a hanning window and 800 lines. What frequency span is required to accurately measure these two frequency disturbances ?
  • 39. Jack D. Peters The X Scale 39 Using Resolution Resolution = 30 - 29.5 = 0.5 Hz / Line Resolution = 2 (Bandwidth) BW = (Frequency Span / Analyzer Lines) Window Function Resolution = 2 (Frequency Span / 800) 1.5 0.5 = 2 (Frequency Span / 800) 1.5 0.5 = 3 (Frequency Span) / 800 400 = 3 (Frequency Span) 133 Hz = Frequency Span
  • 40. Jack D. Peters The X Scale 40 Data Sampling Time Data sampling time is the amount of time required to take one record or sample of data. It is dependent on the frequency span and the number of analyzer lines being used. TSample = Nlines / Fspan Using 400 lines with a 800 Hz frequency span will require: 400 / 800 = 0.5 seconds
  • 41. Jack D. Peters The X Scale 41 Average & Overlap • Average - On • Overlap Percent - 50% TR#1 TR#2 TR#3 FFT#1 FFT#2 FFT#3 TR#1 TR#2 TR#3 FFT#1 FFT#2 FFT#3 0% Overlap 50% Overlap How long will it take for 10 averages at 75% overlap using a 800 line analyzer and a 200 Hz frequency span?
  • 42. Jack D. Peters The X Scale 42 75% Overlap ? • 10 Averages • 75% Overlap • 800 Lines • 200 Hz Average #1 = 800 / 200 Average #1 = 4 seconds Average #2 - #10 = (4 x 0.25) Average #2 - #10 = 1 second each Total time = 4 + (1 x 9) Total time = 13 seconds
  • 43. Jack D. Peters The Y Scale 43 The Y Scale
  • 44. Jack D. Peters The Y Scale 44 Amplitude The “Y” scale provides the amplitude value for each signal or frequency. Default units for the “Y” scale are volts RMS. Volts is an Engineering Unit (EU). RMS is one of three suffixes meant to confuse you ! The other two are: (Peak) and (Peak - Peak)
  • 45. Jack D. Peters The Y Scale 45 Pk-Pk (Peak - Peak) 1 V -1 Real ms62.469480 s Time 1 2 V Pk-Pk 0 Magnitude Hz1000 Hz Pwr Spec 1 dX:9.094238 ms dY:1.994871 V X:22.43042 ms Y:-993.8563 mV X:55 Hz Y:1.999169 V The Peak - Peak value is expressed from the peak to peak amplitude. The spectrum value uses the suffix “Pk-Pk” to denote this.
  • 46. Jack D. Peters The Y Scale 46 Pk (Peak) 1 V -1 Real ms62.469480 s Time 1 1 V Peak 0 Magnitude Hz1000 Hz Pwr Spec 1 dX:4.516602 ms dY:997.4356 mV X:27.00806 ms Y:3.579427 mV X:55 Hz Y:999.5843 mVThe time wave has not changed. The Peak value is expressed from zero to the peak amplitude. The spectrum value uses the suffix “Peak” to denote this.
  • 47. Jack D. Peters The Y Scale 47 RMS (Root Mean Square) 1 V rms 0 Magnitude Hz1000 Hz Pwr Spec 1 1 V -1 Real ms62.469480 s Time 1 X:55 Hz Y:706.8129 mV dX:2.288818 ms dY:709.1976 mV X:27.00806 ms Y:3.579427 mV The time wave has not changed. The RMS value is expressed from zero to 70.7% of the peak amplitude. The spectrum value uses the suffix “RMS” to denote this.
  • 48. Jack D. Peters The Y Scale 48 Suffix Comparison 2 V rms 0 Magnitude Hz1000 Hz Pwr Spec 1 2 V Peak 0 Magnitude Hz1000 Hz Pwr Spec 1 2 V Pk-Pk 0 Magnitude Hz1000 Hz Pwr Spec 1 1 V -1 Real ms62.469480 s Time 1 1 V -1 Real ms62.469480 s Time 1 1 V -1 Real ms62.469480 s Time 1 X:55 Hz Y:706.8129 mV X:55 Hz Y:999.5843 mV X:55 Hz Y:1.999169 V dX:2.288818 ms dY:709.1976 m X:27.00806 ms Y:3.579427 mV dX:4.516602 ms dY:997.4356 m X:27.00806 ms Y:3.579427 mV dX:9.094238 ms dY:1.994871 V X:22.43042 ms Y:-993.8563 mV RMS Peak Peak - Peak
  • 49. Jack D. Peters The Y Scale 49 Changing Suffixes Many times it is necessary to change between suffixes. Pk-Pk / 2 = Peak Peak x 0.707 = RMS RMS x 1.414 = Peak Peak x 2 = Pk-Pk
  • 50. Jack D. Peters The Y Scale 50 Standard Suffixes Now that we have learned all about the three standard suffixes that might possibly confuse the “Y” scale values, what is the standard ? Vibration Institute: Displacement = mils Peak - Peak Velocity = in/s Peak or rms.. Acceleration = g’s Peak or rms.. Note: 1 mil = 0.001 inches
  • 51. Jack D. Peters The Y Scale 51 Engineering Units (EU) Engineering units are used to give meaning to the amplitude of the measurement. Instead of the default “volts”, it is possible to incorporate a unit proportional to volts that will have greater meaning to the user. Examples: 100 mV / g 20 mV / Pa 1 V / in/s 200 mV / mil 50 mV / psi 10 mV / fpm 33 mV / % 10 mV / V
  • 52. Jack D. Peters The Y Scale 52 EU’s the Hard Way Sometimes we forget to use EU’s, or just don’t understand how to set up the analyzer. There is no immediate need to panic if ???? You know what the EU is for the sensor you are using. Example: An accelerometer outputs 100 mV / g and there is a 10 mV peak in the frequency spectrum. What is the amplitude in g’s ? Answer = 10 mV / 100 mV = 0.1 g
  • 53. Jack D. Peters The Y Scale 53 The Big Three EU’s Acceleration Velocity Displacement
  • 54. Jack D. Peters The Y Scale 54 Converting the Big 3 In many cases we are confronted with Acceleration, Velocity, or Displacement, but are not happy with it. Maybe we have taken the measurement in acceleration, but the model calls for displacement. Maybe we have taken the data in displacement, but the manufacturer quoted the equipment specifications in velocity. How do we change between these EU’s ?
  • 55. Jack D. Peters The Y Scale 55 386.1 What ? 1g = 32.2 feet/second2 32.2 feet 12 inches second2 X foot 386.1 inches/second2 g
  • 56. Jack D. Peters The Y Scale 56 Go With The Flow I Acceleration (g’s) Velocity (inch/s) Displacement (inch) x 386.1 ÷ 2(Pi)f ÷ 2(Pi)fx 2(Pi)f x 2(Pi)f ÷ 386.1
  • 57. Jack D. Peters The Y Scale 57 Metric Go With The Flow I Acceleration (g’s) Velocity (mm/s) Displacement (mm) x 9807 ÷ 2(Pi)f ÷ 2(Pi)fx 2(Pi)f x 2(Pi)f ÷ 9807
  • 58. Jack D. Peters The Y Scale 58 Go With The Flow II Peak - Peak Peak RMS ÷ 2 x .707x 1.414 x 2
  • 59. Jack D. Peters The Y Scale 59 Doing the Math Units 0.5g x 386.1 inches second2 g 2π x 25 cycles second 0.5g x 386.1 inches x 1 second g second2 2π x 25 cycles 0.5 x 386.1 inches 2π x 25 cycles second cycle 1.23 inches/second There is a 0.5 g vibration at 25 Hz. What is the velocity ?
  • 60. Jack D. Peters The Y Scale 60 Acceleration - Velocity Example: Find the equivalent peak velocity for a 25 Hz vibration at 7 mg RMS ? = (g x 386.1) / (2 Pi x F) = (0.007 x 386.1) / (6.28 x 25) = 0.017 inches / second RMS Answer = 0.017 x 1.414 = 0.024 inches / second Pk
  • 61. Jack D. Peters The Y Scale 61 Velocity - Displacement Example: Find the equivalent pk-pk displacement for a 25 Hz vibration at 0.024 in/s Pk ? = Velocity / (2 Pi x F) = 0.024 / (6.28 x 25) = 0.000153 inches Pk Answer = 0.000153 x 2 = 0.000306 inches Pk-Pk
  • 62. Jack D. Peters The Y Scale 62 Acceleration - Displacement Example: Find the equivalent Pk-Pk displacement for a 52 Hz vibration at 15 mg RMS ? = (g x 386.1) / (2 Pi x F)2 = (0.015 x 386.1) / (6.28 x 52)2 = 0.000054 inches RMS Answer = (0.000054 x 1.414) 2 = 0.000154 inches Pk-Pk
  • 64. Jack D. Peters Sensors 64 Accelerometers • Integrated Circuit Electronics inside Industrial • Charge Mode Charge Amplifier Test & Measurement
  • 65. Jack D. Peters Sensors 65 Accelerometer Advantages • Measures casing vibration • Measures absolute motion • Can integrate to Velocity output • Easy to mount • Large range of frequency response • Available in many configurations
  • 66. Jack D. Peters Sensors 66 Accelerometer Disadvantages • Does not measure shaft vibration • Sensitive to mounting techniques and surface conditions • Difficult to perform calibration check • Double integration to displacement often causes low frequency noise • One accelerometer does not fit all applications
  • 67. Jack D. Peters Sensors 67 Mass & Charge Mass Ceramic/Quartz Post Relative movement between post & mass creates shear in ceramic producing charge.
  • 68. Jack D. Peters Sensors 68 Accelerometer Parameters Performance Suited for Application Sensitivity (mV/g) Frequency Response of target (f span) Dynamic Range of target (g level)
  • 69. Jack D. Peters Sensors 69 Mounting the Accelerometer 500 2000 6,500 10,000 15,000 15,000 Hz.
  • 70. Jack D. Peters Sensors 70 Realistic Mounting Stud Bees Wax Adhesive Magnet Hand Held 100 1,000 10,000 Frequency, Hz In the real world, mounting might not be as good as the manufacturer had in the lab ! What happened to the high frequency ?
  • 71. Jack D. Peters Sensors 71 Mounting Location Axial Horizontal Vertical Load Zone Radial Vertical Horizontal Axial
  • 72. Jack D. Peters Sensors 72 Mounting Location Load Zone Radial Vertical Horizontal Axial
  • 73. Jack D. Peters Sensors 73 Accelerometer Alarms Machine Condition rms peak Acceptance of new or repaired equipment < 0.08 < 0.16 Unrestricted operation (normal) < 0.12 < 0.24 Surveillance 0.12 - 0.28 0.24 - 0.7 Unsuitable for Operation > 0.28 > 0.7 Velocity Limit Note #1: The rms velocity (in/sec) is the band power or band energy calculated in the frequency spectrum. Note #2: The peak velocity (in/sec) is the largest positive or negative peak measured in the time waveform.
  • 75. Jack D. Peters Sensors 75 Proximity Probe Theory Driver Target Cable Probe The tip of the probe broadcasts a radio frequency signal into the surrounding area as a magnetic field. If a conductive target intercepts the magnetic field, eddy currents are generated on the surface of the target, and power is drained from the radio frequency signal. As the power varies with target movement in the radio frequency field, the output voltage of the driver also varies. A small dc voltage indicates that the target is close to the probe tip. A large dc voltage indicates that the target is far away from the probe tip. The variation of dc voltage is the dynamic signal indicating the vibration or displacement.
  • 76. Jack D. Peters Sensors 76 Output Values • Typical – 100 mv/mil – 200 mv/mil • Depends on probe, cable (length), and driver. • Target material varies output. Calibration Examples • Copper 380 mV/mil • Aluminum 370 mV/mil • Brass 330 mV/mil • Tungsten Carbide 290 mV/mil • Stainless Steel 250 mV/mil • Steel 4140, 4340 200 mV/mil Based on typical output sensitivity of 200 mV/mil.
  • 77. Jack D. Peters Sensors 77 Proximity Probes - Advantages • Non-contact • Measure shaft dynamic motion • Measure shaft static position (gap) • Flat frequency response dc – 1KHz • Simple calibration • Suitable for harsh environments
  • 78. Jack D. Peters Sensors 78 Proximity Probes - Disadvantages • Probe can move (vibrate) • Doesn’t work on all metals • Plated shafts may give false measurement • Measures nicks & tool marks in shaft • Must be replaced as a unit (probe, cable & driver) • Must have relief at sensing tip from surrounding metal
  • 79. Jack D. Peters Sensors 79 Typical Mounting vertical probe horizontal probe H V time Facing Driver to Driven (independent of rotation)
  • 80. Jack D. Peters Sensors 80 Looking at Orbits Vertical for Amplitude Horizontal for Time Base
  • 81. Jack D. Peters Sensors 81 The Orbit Display ils Mils Mils
  • 86. Jack D. Peters Sensors 86 And the problem is ?
  • 87. Jack D. Peters Sensors 87 Proximity Probe Alarms Machine Condition < 3,600 RPM < 10,000 RPM Normal 0.3 0.2 Surveillance 0.3 - 0.5 0.2 - 0.4 Planned Shutdown 0.5 0.4 Unsuitable for Operation 0.7 0.6 Allowable R/C Note #1: R is the relative displacement of the shaft measured by either probe in mils peak-peak. Note #2: C is the diametrical clearance (difference between shaft OD and journal ID) measured in mils.
  • 88. Jack D. Peters Sensors 88 Analyzer Input - Front End • Coupling - AC, DC • Antialias Filter - On, Off AC coupling will block the DC voltage. It creates an amplitude error below 1 Hz. DC coupling has no error below 1 Hz, but the analyzer must range on the total signal amplitude. Prevents frequencies that are greater than span from wrapping around in the spectrum. Analyzer Input Capacitor Blocks DC AC Coupling Capacitor in DSA If the antialias filter is turned off, at what frequency will 175 Hz. appear using a 0 - 100 Hz span, and 800 lines ? 1024/800 = 1.28 100 x 1.28 = 128 Hz 175 Hz - 128 Hz = 47 Hz. 128 Hz - 47 Hz = 81 Hz
  • 89. Jack D. Peters Sensors 89 Low End Frequency Response 0.01 V rms 0.002 Magnitude Hz250 Hz Input 1 0.01 V rms 0 Magnitude Hz250 Hz Output 2 2 0 Magnitude Hz250 Hz Freq Resp 2:1 1.1 0.9 Magnitude Hz250 Hz Coherence 2:1 X:2.8125 Hz Y:984.7542 m X:500 mHz Y:720.0918 m X:5.34375 Hz Y:1.000001 To the right is a typical problem with frequency response at the low end of the frequency spectrum. This low end roll off was a result of AC coupling on CH #2 of the analyzer. Values below 2.8 Hz are in error, and values less than 0.5 Hz should not be used.
  • 90. Jack D. Peters Data Collection 90 Data Collection
  • 91. Jack D. Peters Data Collection 91 Tape Recorders “Insurance Policy” Multi-channel digital audio tape recorders. For the Measurement that can’t get away !
  • 92. Jack D. Peters Data Collection 92 Dynamic Signal Analyzers “Test & Measurement” Large PC driven solutions with multiple channels and windows based software. Smaller portable units with 2 – 4 channel inputs and firmware operating systems.
  • 93. Jack D. Peters Data Collection 93 Data Collectors “Rotating Equipment”
  • 94. Jack D. Peters Data Collection 94 Data Collectors “Rotating Equipment” • Route Based • Frequency Spectrum • Time Waveform • Orbits • Balancing • Alignment • Data Analysis • History • Trending • Download to PC • Alarms • “Smart” algorithms
  • 95. Jack D. Peters Beginning Vibration 95 Bibliography • Eisenmann, Robert Sr. & Eisenmann, Robert Jr., Machinery Malfunction Diagnosis and Correction, ISBN 0-13-240946-1 • Eshleman, Ronald L., Basic Machinery Vibrations, ISBN 0- 9669500-0-3 • LaRocque, Thomas, Vibration Analysis Design, Selection, Mounting, and Installation, Application Note, Connection Technology Center • Agilent Technologies, The Fundamentals of Signal Analysis, Application note 243 • Agilent Technologies, Effective Machinery Measurements using Dynamic Signal Analyzers, Application note 243-1
  • 96. Jack D. Peters Beginning Vibration 96 Thank You ! You can find technical papers on this and other subjects at www.ctconline.com in the “Technical Resources” section