ARCHETYPE CONDO PROJECT
800 hectares of mixed use development
                                  ARCHETYPE CONDO PROJECT
 475 hectares parks and open spaces
 40,000 new homes
 40,000 new jobs                                                        West Don Lands




                                               East Bayfront   Lower Don Lands
                          Central Waterfront




The largest urban renewal project in North America
ARCHETYPE CONDO PROJECT




Revitalization not just redevelopment
ARCHETYPE CONDO PROJECT
                          • South-East
                            Corner of Mill
                            Street and
                            Cherry Street

                          • Extension of
                            Distillery
                            District to the
                            West

                          • 579
                            Residential
                            Units
ARCHETYPE CONDO PROJECT
ARCHETYPE CONDO PROJECT




Setting the Baseline
ARCHETYPE CONDO PROJECT
ARCHETYPE CONDO PROJECT

Several ‘Performance’ Options:




                                       0% better, plus
 5% Better
                                           SB-10
ARCHETYPE CONDO PROJECT
IDP - Revit > Green Building Studio
ARCHETYPE CONDO PROJECT
IDP - Green Building Studio > eQuest modeling
                                        software
ARCHETYPE CONDO PROJECT

Results Breakdown
                                                Lights     Misc
End Use                  ekWh                            Equipment
Lights                 325,776                               Cooling
Misc Equipment         374,031
Cooling                430,197   Domestic
Pumps                  286,134   Hot Water                      Pumps
Fans                   650,291
Heating              3,043,492
Domestic Hot Water   1,503,273                              Fans

Fuel
Electricity (kWh)    1,963,108
Natural Gas (ekWh)   4,319,427      Heating
ARCHETYPE CONDO PROJECT
          Envelope Requirements


                  OBC / ASHRAE 90.1      Typical residential
                  Baseline               construction

Roof              R-20.8 overall         R-20.8 overall
                                         minimum

Glazing           0.55 U value; 40% of   0.55 U value (0.30
                  wall area              Centre of Glass); 70%
                                         of wall area

Walls             R-15.6 overall         R-11 overall (R-21
                                         nominal)
ARCHETYPE CONDO PROJECT

Envelope Requirements
                          Spandrel back pan –
                           2 x 1 inch Roxul
                           insulation:
                              Nominal R-8
                                (overall R-5)

                          Batt insulation in
                           metal framing:
                             Nominal R-13
                                (overall R-7)

                          Total R-11 Overall
ARCHETYPE CONDO PROJECT

Waterfront Toronto – Archetype Condominiums, Base Building
                                                          Base Building
        Roof Assemblies and R value                      IEAD; 20.8 R Value
        Wall Assemblies and R Value                  Steel Framed; 15.6 R Value
         Window Type and U Value                 Metal Framed; 0.55 Total U Value;
           Window to Wall Ratio                                 40%
     Floor, Slab Assemblies and R Value                           -
         Balcony Isolation and Edge                             N/A
      Space Heating Type and Efficiency     Central Atmospheric HW Boiler; 80% Efficient
             Pumps and Drives                              Constant Speed
      Space Cooling Type and Efficiency   Centrifugal Chiller with Cooling Tower; COP of 6.1
       Ventilation and Pressurization                 Combined 100 cfm/Suite
           Metering and Controls                                None
               Lighting Loads                               6.6 W/sq.m.
             Low Flow Fixtures                                    -
          Onsite Energy Production                              None
             Renewable Energy                                   None
            Net Energy Reduction                                  -
         Energy Fuel Cost Reduction                               -
               GHG Reduction                                      -
ARCHETYPE CONDO PROJECT




Improve Net Energy Performance
             by 5%
ARCHETYPE CONDO PROJECT

Archetype Base Building vs. 5% Energy Performance Improvement
                                                  Base Building
                                                  Base Building                          Proposed Building
                                                                                        Proposed Building
   Roof Assemblies and R value
    Roof Assemblies and R value                  IEAD; 20.8 R Value
                                                IEAD; 20.8 R Value                        IEAD; 20.8 R R Value
                                                                                            IEAD; 20.8 value
   Wall Assemblies and R Value              Steel Framed; 15.6 R Value           Steel Framed; 11.0 R 11.0 R Value
                                                                                        Steel Framed; value
    Wall Assemblies and R Value
    Window Type and U Value                Steel Framed; 15.6 R Value
                                         Metal Framed; 0.55 Total U Value;       Metal Framed; 0.35 total U value
                                                                                    Metal Framed; 0.35 Total U Value
     Window Type and U Value            Metal Framed; 0.55 Total U Value;                           -
       Window to Wall Ratio                             40%                                          65%
        Window to Wall Ratio                           40%                                         65%
%Floor, Slab Assemblies and Value
Floor, Slab Assemblies and R R Value                      --                                        - -
    Balcony Isolation and Edge                          N/A                         Central Atmospheric with Lead
                                                                                                     N/A
     Balcony Isolation and Edge                        N/A                       Condensing HW Boiler; 89% Efficient
                                                                                      Central Atmospheric with Lead
                                        Central Atmospheric HW Boiler; 80%                     (Effective)
Space Heating Type and Efficiency                                                  Condensing HW Boiler; 89% Efficient
                                                      Efficient                  Centrifugal VSD Chiller with Cooling
                                       Central Atmospheric HW Boiler; 80%                        (Effective)
 Space Heating Type and Efficiency                                                 Tower; COP of 6.1; IPLV of 0.325
        Pumps and Drives                             Efficient
                                                   Constant Speed                             Constant Speed
                                                                                                kW/Ton
                                       Centrifugal Chiller with Cooling Tower;    Centrifugal Chiller with Cooling Tower;
Space Cooling Type and Efficiency
        Pumps and Drives                          Constant Speed
                                                     COP of 6.1                      COP ofConstant Speed
                                                                                             6.1; IPLV of 0.325kW/ton
  Ventilation and Pressurization              Combined 100 cfm/Suite                     Combined 100 cfm/Suite
                                       Centrifugal Chiller with Cooling Tower;
 Space Cooling Type and Efficiency                                                   Combined 100 cfm per suite
     Metering and Controls                               None
                                                     COP of 6.1                                     None
   Ventilation and Loads
          Lighting Pressurization            Combined 100 CFM/Suite
                                                     6.6 W/sq.m.                                  None
                                                                                                6.6 W/sq.m.
      Metering and Controls                              None                                 6.6 W/sq.m.
                                                                                 Low Flow Showerheads 1.5 gpm. Faucets
                                                                                   Low flow showerheads 1.5 gpm,
        Low Flow Fixtures                                   -
           Lighting Loads                           6.6 W/sq.m.                                   1.0 gpm
                                                                                            faucets 1.0 gpm
    Onsite Energy Production
     Onsite Energy Production                          None
                                                       None                                         None
                                                                                                  None
        Renewable Energy
       Renewable Energy                                None
                                                       None                                       None
                                                                                                    None
      Net Energy Reduction                               -                               318,364 kWh (5.1%)
      Net Energy Reduction                                -                                318,364 kWh (5.1%)
    Energy Fuel Cost Reduction                           -                                 -$10,840 (-3.4%)
   EnergyGHG Reduction
           Fuel Cost Reduction                           --                                   -$10,840 (-3.4%)
                                                                                        67,771 kg CO2e (5.0%)
         GHG Reduction                                    -                               67,771 kg CO2e (5.0%)
ARCHETYPE CONDO PROJECT

Internat Energy Solutions – 5% Energy Performance Improvement

Energy Conservation Measures (ECMs)

  ECM 1 – Upgrade heating boilers to high efficiency atmospheric units with a
  lead condensing boiler

  ECM 2 – Upgrade chiller to a VSD centrifugal chiller

  ECM 3 – Upgrade domestic hot water boilers to high efficiency condensing
  boilers

  ECM 4 – Upgrade to low flow showerheads and faucets

  ECM 5 – Upgrade window-wall assembly to high performance glazing
  system

  ECM 6 – Reduce window-to-wall ratio to 65%
                                                         Note: Each ECM is cumulative
ARCHETYPE CONDO PROJECT

Energy Use Table – 5% Energy Performance Improvement



                         Consumption
             Electricity      Gas         Total    Incremental       Performance
               (kWh)         (m3)        (kWh)       Change           Relative to
                                                       (%)             Baseline
                                                                         (%)
Reference   2,413,200     492,000      7,500,900   -             -19.4
ECM 1       2,413,200     456,000      7,128,700   5.0           -13.5
ECM 2       2,163,300     456,000      6,878,800   3.5           -9.5
ECM 3       2,163,300     432,800      6,638,500   3.5           -5.7
ECM 4       2,163,300     417,600      6,481,800   2.4           -3.2
ECM 5       2,226,800     369,500      6,047,000   6.7           3.7
ECM 6       2,179,100     366,100      5,964,200   1.4           5.1


                                                         Note: Each ECM is cumulative
ARCHETYPE CONDO PROJECT

Energy Use Chart – 5% Energy Performance Improvement



                 Lights
                              Cooling
                   5%
                                6%                 Heating
                                                    45%
Misc Equipment
      6%



Pumps & Aux.
    6%

                      Fans
                      13%

                                          DHW
                                          19%
ARCHETYPE CONDO PROJECT




Improve Net Energy Performance by
              15%
ARCHETYPE CONDO PROJECT

Archetype Base Building vs. 15% Energy Performance Improvement
                                                 Base Building                          Proposed Building
   Roof Assemblies and R value                  IEAD; 20.8 R Value                        IEAD; 20.8 R Value
  Wall Assemblies and R Value              Steel Framed; 15.6 R Value                 Steel Framed; 11 R Value
    Window Type and U Value             Metal Framed; 0.55 Total U Value          Metal Framed; 0.35 Total U Value
      Window to Wall Ratio                             40%                                       70%
Floor, Slab Assemblies and R Value                       -                                         -
   Balcony Isolation and Edge                          N/A                                       N/A
                                      Central Atmospheric HW Boiler; 80%
Space Heating Type and Efficiency                                                     88% Efficient Forced Draft
                                                   Efficient
        Pumps and Drives                         Constant Speed                            Constant Speed
                                      Centrifugal Chiller with Cooling Tower;   Centrifugal Chiller with Cooling Tower;
Space Cooling Type and Efficiency
                                                    COP of 6.1                                COP of 6.1
  Ventilation and Pressurization            Combined 100 cfm/Suite                           In Suite ERV
     Metering and Controls                            None                                      None
         Lighting Loads                            6.6 W/sq.m.                               6.6 W/sq.m.
        Low Flow Fixtures                                -                                    Low flow
    Onsite Energy Production                          None                                      None
       Renewable Energy                               None                                      None
      Net Energy Reduction                               -                              992,166ekWh (15.8%)
   Energy Fuel Cost Reduction                            -                                -$63,600 (-19.9%)
         GHG Reduction                                   -                            210,351 kg CO2e (15.6%)
ARCHETYPE CONDO PROJECT

MCW Consultants– 15% Energy Performance Improvement

Energy Conservation Measures (ECMs)

  ECM 1 – In-Suite Energy Recovery Ventilation

  ECM 2 – 88% Efficient Boiler

  ECM 3 – 95% Efficient DHW Heater

  ECM 4 – Low Flow DHW Fixtures

  ECM 5 – U0.35 Window




                                                 Note: Each ECM is cumulative
ARCHETYPE CONDO PROJECT

Energy Use Table – 15% Energy Performance Improvement


                          Consumption
            Electricity       Gas         Total     Incremental      Performance
              (kWh)          (m3)        (ekWh)       Change          Relative to
                                                        (%)            Baseline
                                                                         (%)

Reference   2,413,244       491,578     7,501,072        -               -19.4
ECM 1       2,876,447       383,502     6,845,689       8.7               -9.0
ECM 2       2,881,645       317,521     6,167,992       9.9                1.8
ECM 3       2,881,645       294,588     5,930,632       3.8                5.6
ECM 4       2,881,645       264,272     5,616,859       5.3               10.6
ECM 5       2,983,188       222,935     5,290,563       5.8               15.8


                                                             Note: Each ECM is cumulative
ARCHETYPE CONDO PROJECT

    Energy Use Chart – 15% Energy Performance Improvement

                  15% Energy Performance Improvement
                                     Area Lights, 6%
                                                                        Space Cool, 14%
                  Misc. Equip., 7%

   Pumps & Aux., 9%




                                                                                          Space Heat, 26%


Vent. Fans, 20%




                                                       Hot Water, 18%
ARCHETYPE CONDO PROJECT




Improve Net Energy Performance by
              25%
ARCHETYPE CONDO PROJECT

  Archetype Base Building vs. 25% Energy Performance Improvement
                                                Base Building                          Proposed Building
   Roof Assemblies and R value                 IEAD; 20.8 R Value                        IEAD; 20.8 R Value
  Wall Assemblies and R Value             Steel Framed; 15.6 R Value                 Steel Framed; 15.6 R Value
    Window Type and U Value            Metal Framed; 0.55 Total U Value;         Metal Framed; 0.55 Total U Value;
      Window to Wall Ratio                            40%                                      70%
Floor, Slab Assemblies and R Value                      -                                        -
   Balcony Isolation and Edge                         N/A                                       N/A
                                     Central Atmospheric HW Boiler; 80%        Vertical Ground Loop HX; Heating COP :
Space Heating Type and Efficiency
                                                  Efficient                                      3.9
        Pumps and Drives                        Constant Speed                            Variable Speed
                                     Centrifugal Chiller with Cooling Tower;   Vertical Ground Loop HX; Cooling EER :
Space Cooling Type and Efficiency
                                                   COP of 6.1                                   18.1
  Ventilation and Pressurization           Combined 100 cfm/Suite                     Combined 100 cfm/Suite
     Metering and Controls                           None                                      None
         Lighting Loads                           6.6 W/sq.m.                               6.6 W/sq.m.
    Onsite Energy Production                         None                                      None
       Renewable Energy                              None                                      None
      Net Energy Reduction                              -                                      37.2%
   Energy Fuel Cost Reduction                           -                                      11.1%
         GHG Reduction                                  -                                      40.2%
ARCHETYPE CONDO PROJECT

Footprint– 25% Energy Performance Improvement

Energy Conservation Measures (ECMs)

  ECM 1 – Market Building with Geo-Exchange System

  ECM 2 – Variable Speed Drives
ARCHETYPE CONDO PROJECT

Energy Use Chart - 25% Energy Performance Improvement
ARCHETYPE CONDO PROJECT

    Sustainable Buildings Canada would like to thank our volunteer design
           team for their time and efforts in completing this project



•    Michelle Xuereb – Quadrangle Architects
•    Katy Mulla – Quadrangle Architects
•    John Janzen – Autodesk
•    Craig McIntyre – Provident energy management
•    Adam Barker – Provident energy management
•    Ian Stahlbrand – Internat Energy Solutions
•    Brian Tysoe – MCW Consultants Ltd.
•    Lyle Scott – S.A. Footprint
•    Shaheen Asif – S.A. Footprint
ARCHETYPE CONDO PROJECT


                Principle Sponsors
Thank you to our Principle Sponsors and Proponent who’s financial and
resource support made this project possible.

More Related Content

Similar to Waterfront Toronto Archetype Condo Project

Thermal bridges in concrete construction solutions to address energy code co...
Thermal bridges in concrete construction  solutions to address energy code co...Thermal bridges in concrete construction  solutions to address energy code co...
Thermal bridges in concrete construction solutions to address energy code co...RDH Building Science
 
Integrative Design Working With Your MEP
Integrative Design Working With Your MEPIntegrative Design Working With Your MEP
Integrative Design Working With Your MEPrbarnwell
 
NBEC 2014 - Balcony Thermal Bridging
NBEC 2014 -  Balcony Thermal BridgingNBEC 2014 -  Balcony Thermal Bridging
NBEC 2014 - Balcony Thermal BridgingRDH Building Science
 
Illuminating art projects
Illuminating art projectsIlluminating art projects
Illuminating art projectsJozhe Fonseca
 
Passive House/AIA MN Convention
Passive House/AIA MN ConventionPassive House/AIA MN Convention
Passive House/AIA MN ConventionTE Studio
 
Adoption and Compliance with Energy Codes: ASHRAE 90.1 and NECB
Adoption and Compliance with Energy Codes: ASHRAE 90.1 and NECBAdoption and Compliance with Energy Codes: ASHRAE 90.1 and NECB
Adoption and Compliance with Energy Codes: ASHRAE 90.1 and NECBRDH Building Science
 
LUSIN DESIGN_30.07.2016
LUSIN DESIGN_30.07.2016LUSIN DESIGN_30.07.2016
LUSIN DESIGN_30.07.2016Shayne Andrews
 
ILS FLP WG 13x2 30W
ILS FLP WG 13x2 30WILS FLP WG 13x2 30W
ILS FLP WG 13x2 30WILS
 
Moving Towards More Energy Efficient Wood Frame Building Enclosures
Moving Towards More Energy Efficient Wood Frame Building EnclosuresMoving Towards More Energy Efficient Wood Frame Building Enclosures
Moving Towards More Energy Efficient Wood Frame Building EnclosuresRDH Building Science
 
Tim Fenn RIMA International Conference invited presentation 2014
Tim Fenn RIMA International Conference invited presentation 2014Tim Fenn RIMA International Conference invited presentation 2014
Tim Fenn RIMA International Conference invited presentation 2014Tim Fenn
 
Residential Presentation 2010 Jan
Residential Presentation 2010 JanResidential Presentation 2010 Jan
Residential Presentation 2010 JanCraig D La Salle
 
Led lighting induction program
Led lighting induction programLed lighting induction program
Led lighting induction programdilipm88
 
Led induction program
Led induction programLed induction program
Led induction programdilipm88
 
Ldb 16 first_partner - lupercales - installazione
Ldb 16 first_partner - lupercales - installazioneLdb 16 first_partner - lupercales - installazione
Ldb 16 first_partner - lupercales - installazionelaboratoridalbasso
 
EGing projects references
EGing projects referencesEGing projects references
EGing projects referencesLeo Lu
 
2010 07-15 rbeem nahbrc marine miranda 07-15-10
2010 07-15 rbeem nahbrc marine miranda 07-15-102010 07-15 rbeem nahbrc marine miranda 07-15-10
2010 07-15 rbeem nahbrc marine miranda 07-15-10Amber Joan Wood
 
Commercial Passive House Case Studies
Commercial Passive House Case StudiesCommercial Passive House Case Studies
Commercial Passive House Case StudiesTE Studio
 
Optimizing Concrete Thermal Bridges - Balcony and Slab Edge Thermal Breaks
Optimizing Concrete Thermal Bridges - Balcony and Slab Edge Thermal BreaksOptimizing Concrete Thermal Bridges - Balcony and Slab Edge Thermal Breaks
Optimizing Concrete Thermal Bridges - Balcony and Slab Edge Thermal BreaksGraham Finch
 

Similar to Waterfront Toronto Archetype Condo Project (20)

AIA Chicago Presentation
AIA Chicago PresentationAIA Chicago Presentation
AIA Chicago Presentation
 
Thermal bridges in concrete construction solutions to address energy code co...
Thermal bridges in concrete construction  solutions to address energy code co...Thermal bridges in concrete construction  solutions to address energy code co...
Thermal bridges in concrete construction solutions to address energy code co...
 
Integrative Design Working With Your MEP
Integrative Design Working With Your MEPIntegrative Design Working With Your MEP
Integrative Design Working With Your MEP
 
NBEC 2014 - Balcony Thermal Bridging
NBEC 2014 -  Balcony Thermal BridgingNBEC 2014 -  Balcony Thermal Bridging
NBEC 2014 - Balcony Thermal Bridging
 
Illuminating art projects
Illuminating art projectsIlluminating art projects
Illuminating art projects
 
Passive House/AIA MN Convention
Passive House/AIA MN ConventionPassive House/AIA MN Convention
Passive House/AIA MN Convention
 
Adoption and Compliance with Energy Codes: ASHRAE 90.1 and NECB
Adoption and Compliance with Energy Codes: ASHRAE 90.1 and NECBAdoption and Compliance with Energy Codes: ASHRAE 90.1 and NECB
Adoption and Compliance with Energy Codes: ASHRAE 90.1 and NECB
 
LUSIN DESIGN_30.07.2016
LUSIN DESIGN_30.07.2016LUSIN DESIGN_30.07.2016
LUSIN DESIGN_30.07.2016
 
ILS FLP WG 13x2 30W
ILS FLP WG 13x2 30WILS FLP WG 13x2 30W
ILS FLP WG 13x2 30W
 
Moving Towards More Energy Efficient Wood Frame Building Enclosures
Moving Towards More Energy Efficient Wood Frame Building EnclosuresMoving Towards More Energy Efficient Wood Frame Building Enclosures
Moving Towards More Energy Efficient Wood Frame Building Enclosures
 
Tim Fenn RIMA International Conference invited presentation 2014
Tim Fenn RIMA International Conference invited presentation 2014Tim Fenn RIMA International Conference invited presentation 2014
Tim Fenn RIMA International Conference invited presentation 2014
 
Residential Presentation 2010 Jan
Residential Presentation 2010 JanResidential Presentation 2010 Jan
Residential Presentation 2010 Jan
 
Led lighting induction program
Led lighting induction programLed lighting induction program
Led lighting induction program
 
Led induction program
Led induction programLed induction program
Led induction program
 
Ldb 16 first_partner - lupercales - installazione
Ldb 16 first_partner - lupercales - installazioneLdb 16 first_partner - lupercales - installazione
Ldb 16 first_partner - lupercales - installazione
 
EGing projects references
EGing projects referencesEGing projects references
EGing projects references
 
2010 07-15 rbeem nahbrc marine miranda 07-15-10
2010 07-15 rbeem nahbrc marine miranda 07-15-102010 07-15 rbeem nahbrc marine miranda 07-15-10
2010 07-15 rbeem nahbrc marine miranda 07-15-10
 
Commercial Passive House Case Studies
Commercial Passive House Case StudiesCommercial Passive House Case Studies
Commercial Passive House Case Studies
 
Optimizing Concrete Thermal Bridges - Balcony and Slab Edge Thermal Breaks
Optimizing Concrete Thermal Bridges - Balcony and Slab Edge Thermal BreaksOptimizing Concrete Thermal Bridges - Balcony and Slab Edge Thermal Breaks
Optimizing Concrete Thermal Bridges - Balcony and Slab Edge Thermal Breaks
 
Solar street light
Solar street lightSolar street light
Solar street light
 

More from Toronto 2030 District

GBF2014 - Rob Thornton - Flexible, Local, Resilient Energy Generation
GBF2014 - Rob Thornton - Flexible, Local, Resilient Energy GenerationGBF2014 - Rob Thornton - Flexible, Local, Resilient Energy Generation
GBF2014 - Rob Thornton - Flexible, Local, Resilient Energy GenerationToronto 2030 District
 
GBF2014 - James Voogt - Climate Change & Cities
GBF2014 - James Voogt - Climate Change & CitiesGBF2014 - James Voogt - Climate Change & Cities
GBF2014 - James Voogt - Climate Change & CitiesToronto 2030 District
 
GBF2014 - Glenn McGillivray - Cities in the Crosshairs
GBF2014 - Glenn McGillivray - Cities in the CrosshairsGBF2014 - Glenn McGillivray - Cities in the Crosshairs
GBF2014 - Glenn McGillivray - Cities in the CrosshairsToronto 2030 District
 
GBF2014 - Paul Dowsett - Resilient Design
GBF2014 - Paul Dowsett - Resilient DesignGBF2014 - Paul Dowsett - Resilient Design
GBF2014 - Paul Dowsett - Resilient DesignToronto 2030 District
 
GBF2014 - Alec Hay - Planning Climate Resilient Cities
GBF2014 - Alec Hay - Planning Climate Resilient CitiesGBF2014 - Alec Hay - Planning Climate Resilient Cities
GBF2014 - Alec Hay - Planning Climate Resilient CitiesToronto 2030 District
 
Closing The Loops in Malmö, Sweden - Daniel Skog
Closing The Loops in Malmö, Sweden - Daniel SkogClosing The Loops in Malmö, Sweden - Daniel Skog
Closing The Loops in Malmö, Sweden - Daniel SkogToronto 2030 District
 
Re-Energizing Our Cities: From District to Specific - Integral Group
Re-Energizing Our Cities:  From District to Specific - Integral GroupRe-Energizing Our Cities:  From District to Specific - Integral Group
Re-Energizing Our Cities: From District to Specific - Integral GroupToronto 2030 District
 
Sustainable Cities through an Integrated Approach - Agneta Persson
Sustainable Cities through an Integrated Approach - Agneta PerssonSustainable Cities through an Integrated Approach - Agneta Persson
Sustainable Cities through an Integrated Approach - Agneta PerssonToronto 2030 District
 
Ampersand: A Sustainable Community - Robert Smith
Ampersand:  A Sustainable Community - Robert SmithAmpersand:  A Sustainable Community - Robert Smith
Ampersand: A Sustainable Community - Robert SmithToronto 2030 District
 
An Emerging Water Management Paradigm - Dr. Khosrow Farabakhsh
An Emerging Water Management Paradigm - Dr. Khosrow FarabakhshAn Emerging Water Management Paradigm - Dr. Khosrow Farabakhsh
An Emerging Water Management Paradigm - Dr. Khosrow FarabakhshToronto 2030 District
 
What is "Model" Sustainability? UniverCity's Journey Toward Sustainability T...
What is "Model" Sustainability?  UniverCity's Journey Toward Sustainability T...What is "Model" Sustainability?  UniverCity's Journey Toward Sustainability T...
What is "Model" Sustainability? UniverCity's Journey Toward Sustainability T...Toronto 2030 District
 
Update on the Enbridge Savings By Design Program
Update on the Enbridge Savings By Design ProgramUpdate on the Enbridge Savings By Design Program
Update on the Enbridge Savings By Design ProgramToronto 2030 District
 
Toronto Green Standard & Energy Efficiency
Toronto Green Standard & Energy EfficiencyToronto Green Standard & Energy Efficiency
Toronto Green Standard & Energy EfficiencyToronto 2030 District
 
The Ins & Outs of Energy Efficiency in the Building Code
The Ins & Outs of Energy Efficiency in the Building CodeThe Ins & Outs of Energy Efficiency in the Building Code
The Ins & Outs of Energy Efficiency in the Building CodeToronto 2030 District
 
Low-Impact Development from the Developer Perspective
Low-Impact Development from the Developer PerspectiveLow-Impact Development from the Developer Perspective
Low-Impact Development from the Developer PerspectiveToronto 2030 District
 
Low-Impact Development Case Study Examples
Low-Impact Development Case Study ExamplesLow-Impact Development Case Study Examples
Low-Impact Development Case Study ExamplesToronto 2030 District
 

More from Toronto 2030 District (20)

GBF2014 - Rob Thornton - Flexible, Local, Resilient Energy Generation
GBF2014 - Rob Thornton - Flexible, Local, Resilient Energy GenerationGBF2014 - Rob Thornton - Flexible, Local, Resilient Energy Generation
GBF2014 - Rob Thornton - Flexible, Local, Resilient Energy Generation
 
GBF2014 - James Voogt - Climate Change & Cities
GBF2014 - James Voogt - Climate Change & CitiesGBF2014 - James Voogt - Climate Change & Cities
GBF2014 - James Voogt - Climate Change & Cities
 
GBF2014 - Glenn McGillivray - Cities in the Crosshairs
GBF2014 - Glenn McGillivray - Cities in the CrosshairsGBF2014 - Glenn McGillivray - Cities in the Crosshairs
GBF2014 - Glenn McGillivray - Cities in the Crosshairs
 
GBF2014 - Paul Dowsett - Resilient Design
GBF2014 - Paul Dowsett - Resilient DesignGBF2014 - Paul Dowsett - Resilient Design
GBF2014 - Paul Dowsett - Resilient Design
 
GBF2014 - Alec Hay - Planning Climate Resilient Cities
GBF2014 - Alec Hay - Planning Climate Resilient CitiesGBF2014 - Alec Hay - Planning Climate Resilient Cities
GBF2014 - Alec Hay - Planning Climate Resilient Cities
 
Closing The Loops in Malmö, Sweden - Daniel Skog
Closing The Loops in Malmö, Sweden - Daniel SkogClosing The Loops in Malmö, Sweden - Daniel Skog
Closing The Loops in Malmö, Sweden - Daniel Skog
 
Re-Energizing Our Cities: From District to Specific - Integral Group
Re-Energizing Our Cities:  From District to Specific - Integral GroupRe-Energizing Our Cities:  From District to Specific - Integral Group
Re-Energizing Our Cities: From District to Specific - Integral Group
 
Sustainable Cities through an Integrated Approach - Agneta Persson
Sustainable Cities through an Integrated Approach - Agneta PerssonSustainable Cities through an Integrated Approach - Agneta Persson
Sustainable Cities through an Integrated Approach - Agneta Persson
 
Ampersand: A Sustainable Community - Robert Smith
Ampersand:  A Sustainable Community - Robert SmithAmpersand:  A Sustainable Community - Robert Smith
Ampersand: A Sustainable Community - Robert Smith
 
An Emerging Water Management Paradigm - Dr. Khosrow Farabakhsh
An Emerging Water Management Paradigm - Dr. Khosrow FarabakhshAn Emerging Water Management Paradigm - Dr. Khosrow Farabakhsh
An Emerging Water Management Paradigm - Dr. Khosrow Farabakhsh
 
What is "Model" Sustainability? UniverCity's Journey Toward Sustainability T...
What is "Model" Sustainability?  UniverCity's Journey Toward Sustainability T...What is "Model" Sustainability?  UniverCity's Journey Toward Sustainability T...
What is "Model" Sustainability? UniverCity's Journey Toward Sustainability T...
 
B bach energy efficiency in obc2012
B bach energy efficiency in obc2012B bach energy efficiency in obc2012
B bach energy efficiency in obc2012
 
Update on the Enbridge Savings By Design Program
Update on the Enbridge Savings By Design ProgramUpdate on the Enbridge Savings By Design Program
Update on the Enbridge Savings By Design Program
 
Toronto Green Standard & Energy Efficiency
Toronto Green Standard & Energy EfficiencyToronto Green Standard & Energy Efficiency
Toronto Green Standard & Energy Efficiency
 
The Ins & Outs of Energy Efficiency in the Building Code
The Ins & Outs of Energy Efficiency in the Building CodeThe Ins & Outs of Energy Efficiency in the Building Code
The Ins & Outs of Energy Efficiency in the Building Code
 
Stormwater Compliance
Stormwater ComplianceStormwater Compliance
Stormwater Compliance
 
SB-10: The Envelope Ultimatum
SB-10: The Envelope UltimatumSB-10: The Envelope Ultimatum
SB-10: The Envelope Ultimatum
 
National Energy Code for Buildings
National Energy Code for BuildingsNational Energy Code for Buildings
National Energy Code for Buildings
 
Low-Impact Development from the Developer Perspective
Low-Impact Development from the Developer PerspectiveLow-Impact Development from the Developer Perspective
Low-Impact Development from the Developer Perspective
 
Low-Impact Development Case Study Examples
Low-Impact Development Case Study ExamplesLow-Impact Development Case Study Examples
Low-Impact Development Case Study Examples
 

Waterfront Toronto Archetype Condo Project

  • 2. 800 hectares of mixed use development ARCHETYPE CONDO PROJECT 475 hectares parks and open spaces 40,000 new homes 40,000 new jobs West Don Lands East Bayfront Lower Don Lands Central Waterfront The largest urban renewal project in North America
  • 3. ARCHETYPE CONDO PROJECT Revitalization not just redevelopment
  • 4. ARCHETYPE CONDO PROJECT • South-East Corner of Mill Street and Cherry Street • Extension of Distillery District to the West • 579 Residential Units
  • 8. ARCHETYPE CONDO PROJECT Several ‘Performance’ Options: 0% better, plus 5% Better SB-10
  • 9. ARCHETYPE CONDO PROJECT IDP - Revit > Green Building Studio
  • 10. ARCHETYPE CONDO PROJECT IDP - Green Building Studio > eQuest modeling software
  • 11. ARCHETYPE CONDO PROJECT Results Breakdown Lights Misc End Use ekWh Equipment Lights 325,776 Cooling Misc Equipment 374,031 Cooling 430,197 Domestic Pumps 286,134 Hot Water Pumps Fans 650,291 Heating 3,043,492 Domestic Hot Water 1,503,273 Fans Fuel Electricity (kWh) 1,963,108 Natural Gas (ekWh) 4,319,427 Heating
  • 12. ARCHETYPE CONDO PROJECT Envelope Requirements OBC / ASHRAE 90.1 Typical residential Baseline construction Roof R-20.8 overall R-20.8 overall minimum Glazing 0.55 U value; 40% of 0.55 U value (0.30 wall area Centre of Glass); 70% of wall area Walls R-15.6 overall R-11 overall (R-21 nominal)
  • 13. ARCHETYPE CONDO PROJECT Envelope Requirements  Spandrel back pan – 2 x 1 inch Roxul insulation:  Nominal R-8 (overall R-5)  Batt insulation in metal framing:  Nominal R-13 (overall R-7)  Total R-11 Overall
  • 14. ARCHETYPE CONDO PROJECT Waterfront Toronto – Archetype Condominiums, Base Building Base Building Roof Assemblies and R value IEAD; 20.8 R Value Wall Assemblies and R Value Steel Framed; 15.6 R Value Window Type and U Value Metal Framed; 0.55 Total U Value; Window to Wall Ratio 40% Floor, Slab Assemblies and R Value - Balcony Isolation and Edge N/A Space Heating Type and Efficiency Central Atmospheric HW Boiler; 80% Efficient Pumps and Drives Constant Speed Space Cooling Type and Efficiency Centrifugal Chiller with Cooling Tower; COP of 6.1 Ventilation and Pressurization Combined 100 cfm/Suite Metering and Controls None Lighting Loads 6.6 W/sq.m. Low Flow Fixtures - Onsite Energy Production None Renewable Energy None Net Energy Reduction - Energy Fuel Cost Reduction - GHG Reduction -
  • 15. ARCHETYPE CONDO PROJECT Improve Net Energy Performance by 5%
  • 16. ARCHETYPE CONDO PROJECT Archetype Base Building vs. 5% Energy Performance Improvement Base Building Base Building Proposed Building Proposed Building Roof Assemblies and R value Roof Assemblies and R value IEAD; 20.8 R Value IEAD; 20.8 R Value IEAD; 20.8 R R Value IEAD; 20.8 value Wall Assemblies and R Value Steel Framed; 15.6 R Value Steel Framed; 11.0 R 11.0 R Value Steel Framed; value Wall Assemblies and R Value Window Type and U Value Steel Framed; 15.6 R Value Metal Framed; 0.55 Total U Value; Metal Framed; 0.35 total U value Metal Framed; 0.35 Total U Value Window Type and U Value Metal Framed; 0.55 Total U Value; - Window to Wall Ratio 40% 65% Window to Wall Ratio 40% 65% %Floor, Slab Assemblies and Value Floor, Slab Assemblies and R R Value -- - - Balcony Isolation and Edge N/A Central Atmospheric with Lead N/A Balcony Isolation and Edge N/A Condensing HW Boiler; 89% Efficient Central Atmospheric with Lead Central Atmospheric HW Boiler; 80% (Effective) Space Heating Type and Efficiency Condensing HW Boiler; 89% Efficient Efficient Centrifugal VSD Chiller with Cooling Central Atmospheric HW Boiler; 80% (Effective) Space Heating Type and Efficiency Tower; COP of 6.1; IPLV of 0.325 Pumps and Drives Efficient Constant Speed Constant Speed kW/Ton Centrifugal Chiller with Cooling Tower; Centrifugal Chiller with Cooling Tower; Space Cooling Type and Efficiency Pumps and Drives Constant Speed COP of 6.1 COP ofConstant Speed 6.1; IPLV of 0.325kW/ton Ventilation and Pressurization Combined 100 cfm/Suite Combined 100 cfm/Suite Centrifugal Chiller with Cooling Tower; Space Cooling Type and Efficiency Combined 100 cfm per suite Metering and Controls None COP of 6.1 None Ventilation and Loads Lighting Pressurization Combined 100 CFM/Suite 6.6 W/sq.m. None 6.6 W/sq.m. Metering and Controls None 6.6 W/sq.m. Low Flow Showerheads 1.5 gpm. Faucets Low flow showerheads 1.5 gpm, Low Flow Fixtures - Lighting Loads 6.6 W/sq.m. 1.0 gpm faucets 1.0 gpm Onsite Energy Production Onsite Energy Production None None None None Renewable Energy Renewable Energy None None None None Net Energy Reduction - 318,364 kWh (5.1%) Net Energy Reduction - 318,364 kWh (5.1%) Energy Fuel Cost Reduction - -$10,840 (-3.4%) EnergyGHG Reduction Fuel Cost Reduction -- -$10,840 (-3.4%) 67,771 kg CO2e (5.0%) GHG Reduction - 67,771 kg CO2e (5.0%)
  • 17. ARCHETYPE CONDO PROJECT Internat Energy Solutions – 5% Energy Performance Improvement Energy Conservation Measures (ECMs) ECM 1 – Upgrade heating boilers to high efficiency atmospheric units with a lead condensing boiler ECM 2 – Upgrade chiller to a VSD centrifugal chiller ECM 3 – Upgrade domestic hot water boilers to high efficiency condensing boilers ECM 4 – Upgrade to low flow showerheads and faucets ECM 5 – Upgrade window-wall assembly to high performance glazing system ECM 6 – Reduce window-to-wall ratio to 65% Note: Each ECM is cumulative
  • 18. ARCHETYPE CONDO PROJECT Energy Use Table – 5% Energy Performance Improvement Consumption Electricity Gas Total Incremental Performance (kWh) (m3) (kWh) Change Relative to (%) Baseline (%) Reference 2,413,200 492,000 7,500,900 - -19.4 ECM 1 2,413,200 456,000 7,128,700 5.0 -13.5 ECM 2 2,163,300 456,000 6,878,800 3.5 -9.5 ECM 3 2,163,300 432,800 6,638,500 3.5 -5.7 ECM 4 2,163,300 417,600 6,481,800 2.4 -3.2 ECM 5 2,226,800 369,500 6,047,000 6.7 3.7 ECM 6 2,179,100 366,100 5,964,200 1.4 5.1 Note: Each ECM is cumulative
  • 19. ARCHETYPE CONDO PROJECT Energy Use Chart – 5% Energy Performance Improvement Lights Cooling 5% 6% Heating 45% Misc Equipment 6% Pumps & Aux. 6% Fans 13% DHW 19%
  • 20. ARCHETYPE CONDO PROJECT Improve Net Energy Performance by 15%
  • 21. ARCHETYPE CONDO PROJECT Archetype Base Building vs. 15% Energy Performance Improvement Base Building Proposed Building Roof Assemblies and R value IEAD; 20.8 R Value IEAD; 20.8 R Value Wall Assemblies and R Value Steel Framed; 15.6 R Value Steel Framed; 11 R Value Window Type and U Value Metal Framed; 0.55 Total U Value Metal Framed; 0.35 Total U Value Window to Wall Ratio 40% 70% Floor, Slab Assemblies and R Value - - Balcony Isolation and Edge N/A N/A Central Atmospheric HW Boiler; 80% Space Heating Type and Efficiency 88% Efficient Forced Draft Efficient Pumps and Drives Constant Speed Constant Speed Centrifugal Chiller with Cooling Tower; Centrifugal Chiller with Cooling Tower; Space Cooling Type and Efficiency COP of 6.1 COP of 6.1 Ventilation and Pressurization Combined 100 cfm/Suite In Suite ERV Metering and Controls None None Lighting Loads 6.6 W/sq.m. 6.6 W/sq.m. Low Flow Fixtures - Low flow Onsite Energy Production None None Renewable Energy None None Net Energy Reduction - 992,166ekWh (15.8%) Energy Fuel Cost Reduction - -$63,600 (-19.9%) GHG Reduction - 210,351 kg CO2e (15.6%)
  • 22. ARCHETYPE CONDO PROJECT MCW Consultants– 15% Energy Performance Improvement Energy Conservation Measures (ECMs) ECM 1 – In-Suite Energy Recovery Ventilation ECM 2 – 88% Efficient Boiler ECM 3 – 95% Efficient DHW Heater ECM 4 – Low Flow DHW Fixtures ECM 5 – U0.35 Window Note: Each ECM is cumulative
  • 23. ARCHETYPE CONDO PROJECT Energy Use Table – 15% Energy Performance Improvement Consumption Electricity Gas Total Incremental Performance (kWh) (m3) (ekWh) Change Relative to (%) Baseline (%) Reference 2,413,244 491,578 7,501,072 - -19.4 ECM 1 2,876,447 383,502 6,845,689 8.7 -9.0 ECM 2 2,881,645 317,521 6,167,992 9.9 1.8 ECM 3 2,881,645 294,588 5,930,632 3.8 5.6 ECM 4 2,881,645 264,272 5,616,859 5.3 10.6 ECM 5 2,983,188 222,935 5,290,563 5.8 15.8 Note: Each ECM is cumulative
  • 24. ARCHETYPE CONDO PROJECT Energy Use Chart – 15% Energy Performance Improvement 15% Energy Performance Improvement Area Lights, 6% Space Cool, 14% Misc. Equip., 7% Pumps & Aux., 9% Space Heat, 26% Vent. Fans, 20% Hot Water, 18%
  • 25. ARCHETYPE CONDO PROJECT Improve Net Energy Performance by 25%
  • 26. ARCHETYPE CONDO PROJECT Archetype Base Building vs. 25% Energy Performance Improvement Base Building Proposed Building Roof Assemblies and R value IEAD; 20.8 R Value IEAD; 20.8 R Value Wall Assemblies and R Value Steel Framed; 15.6 R Value Steel Framed; 15.6 R Value Window Type and U Value Metal Framed; 0.55 Total U Value; Metal Framed; 0.55 Total U Value; Window to Wall Ratio 40% 70% Floor, Slab Assemblies and R Value - - Balcony Isolation and Edge N/A N/A Central Atmospheric HW Boiler; 80% Vertical Ground Loop HX; Heating COP : Space Heating Type and Efficiency Efficient 3.9 Pumps and Drives Constant Speed Variable Speed Centrifugal Chiller with Cooling Tower; Vertical Ground Loop HX; Cooling EER : Space Cooling Type and Efficiency COP of 6.1 18.1 Ventilation and Pressurization Combined 100 cfm/Suite Combined 100 cfm/Suite Metering and Controls None None Lighting Loads 6.6 W/sq.m. 6.6 W/sq.m. Onsite Energy Production None None Renewable Energy None None Net Energy Reduction - 37.2% Energy Fuel Cost Reduction - 11.1% GHG Reduction - 40.2%
  • 27. ARCHETYPE CONDO PROJECT Footprint– 25% Energy Performance Improvement Energy Conservation Measures (ECMs) ECM 1 – Market Building with Geo-Exchange System ECM 2 – Variable Speed Drives
  • 28. ARCHETYPE CONDO PROJECT Energy Use Chart - 25% Energy Performance Improvement
  • 29. ARCHETYPE CONDO PROJECT Sustainable Buildings Canada would like to thank our volunteer design team for their time and efforts in completing this project • Michelle Xuereb – Quadrangle Architects • Katy Mulla – Quadrangle Architects • John Janzen – Autodesk • Craig McIntyre – Provident energy management • Adam Barker – Provident energy management • Ian Stahlbrand – Internat Energy Solutions • Brian Tysoe – MCW Consultants Ltd. • Lyle Scott – S.A. Footprint • Shaheen Asif – S.A. Footprint
  • 30. ARCHETYPE CONDO PROJECT Principle Sponsors Thank you to our Principle Sponsors and Proponent who’s financial and resource support made this project possible.