TQ Analyst
Gamal A. Hamid
Gamal A. Hamid
Contents
ā€¢ Introduction
ā€¢ Software contents
o Menu Bar
o Tool Bar
o Parameter Tabs
o Action & Option buttons
ā€¢ Getting started
2
Gamal A. Hamid
Introduction
3
Gamal A. Hamid
TQA Software
ā€¢ TQ Analyst is a standard Windows application .
ā€¢ The software offers a complete selection of
qualitative and quantitative analytical techniques.
ā€¢ It contains all of the algorithms that are typically used
for calculating component concentrations and
classifying spectra based on a set of standards.
4
Gamal A. Hamid
Quantitative Analysis
ā€¢ Infrared spectroscopy is most often used for
qualitative identification.
ā€¢ An unknown material can be determined by
comparing the infrared spectrum acquired on this
sample to the spectra of known compounds.
ā€¢ Analysis of the infrared spectral band intensities as a
function of solute concentration provides a
straightforward means for determining the
concentration mixture components.
5
Gamal A. Hamid
Software
6
Gamal A. Hamid
Software Contents
The main components of software :-
I. Menu Bar
II. Tool Bar
III. Parameter Tab
IV. Action Buttons
V. Option Buttons
7
Gamal A. Hamid
Analyst Window
8
Gamal A. Hamid
I. Menu Bar
ā€¢ The menus provide useful commands for working with
method files and spectral data.
ā€¢ You will also find a menu of diagnostic commands that can
be used to evaluate a method as you develop it.
ā€¢ Within each menu, the commands are grouped according to
their related functions
9
Gamal A. Hamid
1. File Menu
ā€¢ Displays the commands used to create,
open, save, and print methods from TQ
Analyst and to save a TQ Analyst spectrum
in a file on your disk.
ā€¢ It also explains how to open and run a
completed TQ Analyst method from other
applications and to move method files from
one computer to another.
10
Gamal A. Hamid
2. Edit Menu
ā€¢ Default Method Path to specify a default
directory path for opening and saving.
ā€¢ Default Spectrum Path to specify a default
directory path for opening and saving spectra
ā€¢ Options You can customize the way TQ Analyst
displays certain windows and dialog boxes by
setting options.
ā€¢ Edit Menu lets you create custom Menu
containing buttons for quickly initiating
commands.
11
Gamal A. Hamid
3. View Menu
12
ā€¢ Display Setup to specify how spectra to be displayed
ā€¢ Stacking spectra is useful when you are comparing
spectra that are significantly different.
ā€¢ Hide Spectra to hide the selected spectra from view.
ā€¢ Full Scale to adjust the vertical scale of the spectra .
ā€¢ Common Scale to display all the spectra using the
same Y-axis
ā€¢ Match Scale ,All the spectra in the window are
displayed using the Y-axis limits .
ā€¢ Offset Scale to display the spectra vertically offset
from each other, Separating the spectra.
Gamal A. Hamid
View Menu
ā€¢ Display Limits to specify the X-axis and Y-axis display limits.
ā€¢ Automatic Full Scale automatically displays the spectra full.
ā€¢ Absorbance at a frequency is defined by the equation
A = log(100/%T)
ā€¢ Transmittance IR energy transmitted through the sample.
%T = (S/B)*100 where S is IR intensity
B is IR intensity without a sample in place (background).
ā€¢ Retrieve Interferogram to display the interferogram for the
selected spectrum in the active spectral window.
ā€¢ Reprocess to transform the interferogram data for the selected
spectra using different transformation parameter.
13
Gamal A. Hamid
4. Diagnostic Menu
ā€¢ The Eigenanalysis to start the Eigenanalysis diagnostic
routine.
ā€¢ The Principal Component Spectra to start the Principal
Component Spectra diagnostic routine.
ā€¢ The Pairwise Concentration to start the Pairwise
Concentration diagnostic routine.
ā€¢ The Spectrum Outlier to start the Spectrum Outlier
diagnostic routine.
ā€¢ The Pure Component Spectra to display the synthetic
pure component spectrum for each component in a
quantitative method and one pathlength spectrum.
14
Gamal A. Hamid
Diagnostic Menu 2
ā€¢ The Statistical Spectra to generate a series of synthetic
spectra that illustrate the variation present in the
standards and, for quantitative methods, the spectral
regions that correlate with changes in component
concentration.
ā€¢ Select Standards if you need help choosing appropriate
standards for a quantitative.
ā€¢ The Cross Validation to start the Cross Validation
diagnostic routine.
ā€¢ The External Validation to start the External Validation
diagnostic routine.
15
Gamal A. Hamid
Diagnostic Menu 3
ā€¢ The Residual Spectra to quantify a spectrum using the active
method and then display the residual spectrum or spectra for the
spectrum that was quantified.
ā€¢ The Multiple Quantify to quantify two or more spectra and
store the calculated results in a format that is accessible to other
applications.
ā€¢ The Multiple Summary to quantify two or more spectra and
store a summary of the results in a format that is accessible to
other applications,
ā€¢ The Quantify Sequence or Map calculate component
concentration values from a sequence (*.srs) or map (*.map) file.
16
Gamal A. Hamid
Diagnostic Menu 4
ā€¢ The Principal Component Scores to start the Principal
Component Scores diagnostic routine.
ā€¢ The PRESS to start the PRESS diagnostic routine.
ā€¢ The Factor Loading to start the Factor Loading diagnostic
routine.
ā€¢ The Leverage to start the Leverage diagnostic routine.
ā€¢ The Loading Spectra to start the Loading Spectra diagnostic
routine.
17
Gamal A. Hamid
5. Window Menu and Help
ā€¢ The Window menu show the names of the TQ
Analyst windows that are currently open and allow
you to make an open window active.
ā€¢ Use this command to display the version number for
your TQ Analyst software
18
Gamal A. Hamid
II. Tool Bar
The toolbar allows you to perform operations with the
current method.
1. Calibrate
2. Quantify
3. Explain
4. Performance Index
19
Gamal A. Hamid
1. Calibrate
ā€¢ To analyze a set of calibration standards
in order to calculate a method model for
predicting component concentrations in
unknown samples.
ā€¢ The first time you calibrate a method, the
software calculates a performance index,
which appears next to the Close button
on the toolbar.
ā€¢ If you change the method and then
recalibrate
20
Gamal A. Hamid
2. Quantify
ā€¢ Using the calibration method to
analyze the unknown samples .
21
Gamal A. Hamid
3. Explain
TQ Analyst Explain Help
ā€¢ Explain Help for TQ Analyst tab features
ā€¢ Explain Help for TQ Analyst Diagnostics
ā€¢ Explain Help for the Region Selection task window
ā€¢ Explain Help for the Corrections task window
ā€¢ Explain Help for the Calibration Results window
22
Gamal A. Hamid
4. Performance Index
ā€¢ The performance index for the previous calibration as well
as the index for the new calibration.
ā€¢ If your method has no validation standards, the symbol
"N/A," meaning "not available," is displayed in the toolbar
instead of a performance index.
ā€¢ The indicator to the right of the performance index tells
whether the selected method is calibrated.
ā€¢ If the method has never been calibrated, the bar is red and
the message reads "uncalibrated." After the first calibration,
the bar turns green and the "calibrated" message appears.
23
Gamal A. Hamid
III. Parameter Tabs
ā€¢ Method parameters are grouped by function.
ā€¢ Each group of parameters is contained on a file card which has a tab that is always visible
at the top of the method window.
ā€¢ To display a group of parameters, click the corresponding tab.
24
Gamal A. Hamid
IV. Action Buttons
ā€¢ These buttons, called "action buttons," allow you to perform tasks related to the
selected tab.
ā€¢ For example, the "Suggest" button shown in the illustration below may be used to help
you set the Analysis Type parameter on the description tab.
25
Gamal A. Hamid
V. Option Buttons
ā€¢ Some parameters, such as the Analysis Type and
Pathlength Type, provide a group of option buttons
and allow you to select only one of the available
options.
ā€¢ You can select an option from a group of option
buttons by using the mouse to click the
corresponding button.
26
Gamal A. Hamid
1. Description Tab
ā€¢ Use the parameters on this tab to enter general information
about your method.
ā€¢ A method can be described by its title, developer, revision
number, revision date, and analysis type.
ā€¢ If you need help choosing the proper analysis type for your
samples, use the Analysis Type wizard. To start the wizard,
click the Suggest Analysis Type button on this tab.
ā€¢ The Description tab is displayed for all analysis types.
ā€¢ The information on this tab is saved automatically when you
save the active method.
27
Gamal A. Hamid
Description Action Buttons
ā€¢ the "Suggest" button used to help you set the Analysis Type parameter on the
Description tab.
ā€¢ If you need help choosing the analysis type, use the Analysis Type wizard. To start the
wizard, click the Suggest Analysis Type button at the top of this tab.
ā€¢ Display the How To window if you are looking for quick instructions on how to use the
tools in this window to complete a task. a help window that contains information about
creating TQ Analyst methods is displayed on the screen.
28
Gamal A. Hamid
Description Options Buttons
ā€¢ The Analysis Type parameter defines the type of
results the method will produce when you use it to
analyze an unknown sample spectrum and the
algorithm that will be used for the analysis.
ā€¢ There are three basic types of analyses you can do
with TQ Analyst:
29
Gamal A. Hamid
Analysis Type
1. Quantitative Analysis
ā€¢ Measuring component amounts or concentrations in a sample mixture.
2. Classification
ā€¢ Classifying an unknown sample spectrum by finding the spectrum or group of spectra
that most closely match the sample spectrum or by verifying that the sample spectrum
is similar to the spectra in a specified group.
3. Measurement
ā€¢ Measuring peak heights, peak areas, peak locations, or peak widths in a sample
spectrum or calculating the ratio of two measured peaks.
30
Gamal A. Hamid
2. Pathlength Tab
ā€¢ Sample pathlength is important to quantitative
analyses because the intensities of the peaks in
a sample spectrum are determined by the
thickness as well as the composition of the
sample.
ā€¢ Pathlength is important to a spectral
measurement analysis only when the
measurement data are used for quantitative or
classification purposes.
31
Gamal A. Hamid
Pathlength Action Buttons
ā€¢ Use Suggest Pathlength Type if you are not familiar with the pathlength
treatments provided in TQ Analyst or need help deciding which treatment would
work best for the samples.
ā€¢ Use the Advanced button to access the temperature/pressure and
dilution/extraction features of TQ Analyst software.
ā€¢ Use Edit Region when you need to specify or adjust the pathlength peak for the
Internal Reference or Peak Ratio pathlength type.
32
Gamal A. Hamid
Pathlength Option Buttons
ā€¢ Undecided allows you to postpone choosing the
pathlength type.
ā€¢ You cannot calibrate a method when the pathlength
type is set to Undecided.
ā€¢ Constant type which uses one pathlength value to
calculate component amounts or concentrations in
all of the samples to be analyzed.
ā€¢ Known an option for pathlength type if you are
analyzing samples that have different but known
thicknesses.
33
Gamal A. Hamid
3. Components Tab
ā€¢ The components will be listed in a table.
ā€¢ Each component is described by its name and an
abbreviated name as well as the number of digits and
the unit which will be used to report its
concentration.
ā€¢ Concentration limits, such as analysis limits and
acceptance limits, may also be specified for each
component.
ā€¢ The Components tab is displayed only when the
Analysis Type parameter on the Description tab is set
to a quantitative analysis type,
34
Gamal A. Hamid
Components Action Buttons
ā€¢ This button starts the Assess Feasibility wizard to help you determine if there is
sufficient variability in your sample data that correlates with differences in sample
composition
ā€¢ Use Assess Feasibility to quickly determine if it is possible to create a calibration
model that can calculate the concentrations of the components you want to measure.
35
Gamal A. Hamid
Components Option Buttons
ā€¢ Concentration / Error limits, specify analysis
limits for each component in the method.
ā€¢ Use Concentration Constraints option if you know
all the components in your sample and want their
predicted concentrations to sum to a 100%.
ā€¢ Use Component Interaction to indicate whether
you expect any interactions between the
components you want to measure.
ā€¢ Composite Components is an additional method
component that is computed from the results for one
or more measured components.
36
Gamal A. Hamid
4. Standards Tab
ā€¢ Use the parameters on this tab to describe the standards that
will be used to calibrate, validate, or correct the active method.
ā€¢ The standards will be listed in a table.
ā€¢ Each standard is described by its title and usage.
ā€¢ Some analysis types require additional information for each
standard, such as the concentrations or amounts of the
components the standard contains or the class the standard
belongs to.
ā€¢ The Standards tab is always displayed unless the Analysis Type
parameter on the Description tab is set to Measurement Only.
37
Gamal A. Hamid
Standards Action Buttons
ā€¢ Suggest Standards wizard to help you select the number and component concentrations of
the standards needed to calibrate and validate a quantitative method.
ā€¢ Evaluate Standards wizard to determine whether the number and component conc. of the
standards are appropriate for the components that are specified in the method.
ā€¢ Open Standard to select a spectral data file to use as a standard in the active method.
ā€¢ View Standards to display the spectra of selected standards in your method.
ā€¢ Sort Standards to rearrange the entries in the Standards table.
ā€¢ Ignore Missing Data to reassign to Ignore the usage of any method standards that contain
the PLS missing data indicator value.
38
Gamal A. Hamid
Standards Option Buttons
ā€¢ Show Spectrum Title ,File Names to specify how the standards will be listed in the
Standards table and in other tables within the TQ Analyst software. You may list the
standards by their file names, their titles, or both.
ā€¢ Restrict Y-axis Range to restrict the analysis of your sample spectra to a specified Y-
axis range.
39
Gamal A. Hamid
5. Spectra Tab
ā€¢ Format for spectral data and to apply processing operations to the
data, such as subtraction, smoothing, and baseline correction.
ā€¢ The corrections may be applied to the spectra of the method
standards as well as to any sample spectra you use the method to
analyze.
ā€¢ If you want to specify more than one processing step, we
recommend setting them up in this order:
o Spectral Subtraction,
o Data Format,
o Smoothing,
o Multipoint Baseline Correction.
40
Gamal A. Hamid
Spectra Action Buttons
ā€¢ View Standards button on this tab to display the selected standards before and after
the data have been processed.
ā€¢ View Standards button on the Spectra tab to see the effects of a single processing
sequence, such as smoothing, derivatives, or multi-point baseline correction, on the
selected standards.
41
Gamal A. Hamid
Spectra Option Buttons
ā€¢ Data Format to select a format for the
spectral data you want to analyze. ā€œfirst or
second derivative spectraā€.
ā€¢ Spectral Subtraction allows to set up
automatic subtraction for the spectra used
with this method. Automatic subtraction
subtracts a reference spectrum from the
spectrum of each unknown sample.
ā€¢ Multipoint Baseline Correction to turn on
Multipoint baseline correction and specify
what kind of correction will be used.
42
Gamal A. Hamid
6. Regions Tab
ā€¢ The parameters on this tab to identify the spectral peaks or regions
ā€¢ Each region is described by its index number, measurement type, measurement location,
baseline measurement type, and the locations of the baseline points.
ā€¢ If you are creating a quantitative method, choosing regions that are appropriate for the
selected analysis type and that correlate best with component concentrations.
ā€¢ Once the regions are selected, several iterations of calibrating the method and refining the
region limits, the measurement type, or the baseline points may be required in order to
achieve accurate quantitative results.
43
Gamal A. Hamid
Regions Action Buttons
ā€¢ The Suggest Regions to starts the Regions wizard to help you select the spectral
region or regions that correlate best with the component.
ā€¢ The Edit Regions to choose the proper region limits and baseline points when you
can see the spectra of the standards.
ā€¢ using the Region Selection task window to specify regions rather than entering region
limits and baseline points directly into the Regions table.
44
Gamal A. Hamid
7. Corrections Tab
ā€¢ Use Corrections to define a mathematical equation which will attempt to correct a
method's calibrated model for nonlinearity or bias.
ā€¢ Displayed only with quantitative method type (ACLS, CLS, SMLR, PLS, and PCR.
ā€¢ There are two types of corrections you may specify:
o Linearity corrections
o Bias corrections.
ā€¢ The specified correction will be applied to the values calculated by the calibrated
method to bring them closer to the actual values.
ā€¢ Each correction is described by its index number, component name, and the correction
coefficients for each term in the equation for the correction curve.
45
Gamal A. Hamid
Corrections Action Buttons
ā€¢ The Suggest Corrections starts the Corrections wizard to help you determine
whether corrections are needed for the components in your method and, if so, the
type and degree of correction you should use.
ā€¢ The Edit Corrections to display the Corrections task window for editing the
correction parameters for one or more components in your method.
ā€¢ The Cross Corrections to access the features for setting up a cross correction in
your method.
46
Gamal A. Hamid
Corrections Option Buttons
ā€¢ The Method Correction to specify whether the
active method will include a post-prediction
correction.
ā€¢ The Correction Standards to specify whether all
of your component correction curves will be
generated from a separate set of correction
standards or from a combination of correction
standards and calibration standards.
47
Gamal A. Hamid
8. Report Tab
ā€¢ Use the parameters on this tab to select the
information you want to include in the sample
reports and to turn TQ Analystā€™s sample checking
features on and off.
ā€¢ The Report tab is displayed for all method types.
ā€¢ The information on this tab is saved automatically
when you save the active method.
48
Gamal A. Hamid
Report Option Buttons
49
Gamal A. Hamid
Creating a Method
50
Gamal A. Hamid
Basic Types of Analyses
Quantitative
ā€¢ Measuring component concentrations in a sample mixture.
Classification
ā€¢ Classifying an unknown sample spectrum by finding the
spectrum or group of spectra that most closely match the
sample spectrum.
Measurement
ā€¢ Measuring peak heights or areas, peak locations, or peak
widths in a sample spectrum or calculating the ratio of two
measured peaks.
51
Gamal A. Hamid
Creating a Quantitative Analysis
ā€¢ The File menu to create a new method window.
ā€¢ The Save Method As command in the File menu
to create a method file.
ā€¢ The Description tab and enter a title for your
method. Choose an option for the quantitative
analysis options on the Description tab.
52
Gamal A. Hamid
1. Quantitative Analysis
ā€¢ Select the Simple Beerā€™s Law analysis type when
each of the components you want to measure
produces a unique peak in the spectrum of the
sample mixture.
ā€¢ Select the Classic least Squares CLS analysis type
when each component you want to measure
produces a peak or combination of peaks in the
spectrum of the sample mixture, but the component
peaks overlap significantly.
53
Gamal A. Hamid
2. Pathlength
ā€¢ The Pathlength tab and select an option for the
Pathlength parameter.
ā€¢ The Advanced button displays a window that
allows you to access the temperature/pressure and
dilution/extraction features of TQ Analyst.
ā€¢ Select Constant pathlength type if you are using a
sampling accessory that has a fixed pathlength, such
as a liquid transmission cell.
54
Gamal A. Hamid
3. Components
ā€¢ the Components tab and specify the
components you want to measure and the
analysis limits for each component.
55
Gamal A. Hamid
4. Standards
ā€¢ Describe the standards that will be used to calibrate, validate.
56
Gamal A. Hamid
View Standards
57
Gamal A. Hamid
5. Spectra
ā€¢ Format for spectral data and to apply processing operations to the data, such as
subtraction, smoothing, and baseline correction.
ā€¢ The corrections may be applied to the spectra of the method standards as well as
to any sample spectra you use the method to analyze.
ā€¢ If you want to specify more than one processing step, we recommend setting
them up in this order:
o Spectral Subtraction,
o Data Format,
o Smoothing,
o Multipoint Baseline Correction.
58
Gamal A. Hamid
6. Regions
ā€¢ The Regions tab to see the spectral peaks or regions
59
Gamal A. Hamid
7. Calibrate
ā€¢ Click the Calibrate button on the toolbar to calibrate your method.
60
Gamal A. Hamid
8. Quantify
61
Gamal A. Hamid
9. Report
ā€¢ Click the Report tab and specify the
information you want to include in
your sample reports, including any
spectrum or result warnings.
62
Gamal A. Hamid
10. Save the method
ā€¢ The Save Method command
in the File menu to save your
completed method.
63
Tqa

More Related Content

What's hot

Calabration principles-chapter1
Calabration principles-chapter1Calabration principles-chapter1
Calabration principles-chapter1Complaint2015
Ā 
calibration of analytical instruments
calibration of analytical instruments calibration of analytical instruments
calibration of analytical instruments Lavanya Pinneboina
Ā 
Ilac g24 edition 2007 (e)
Ilac g24 edition 2007 (e)Ilac g24 edition 2007 (e)
Ilac g24 edition 2007 (e)ŲÆ. shaltout
Ā 
Quality assurance part_2
Quality assurance part_2Quality assurance part_2
Quality assurance part_2ThorikulHuda2
Ā 
Analytical Method Validation basics by Dr. A. Amsavel
Analytical Method Validation  basics by Dr. A. AmsavelAnalytical Method Validation  basics by Dr. A. Amsavel
Analytical Method Validation basics by Dr. A. AmsavelDr. Amsavel A
Ā 
aa-automation-apc-complex-industrial-processes
aa-automation-apc-complex-industrial-processesaa-automation-apc-complex-industrial-processes
aa-automation-apc-complex-industrial-processesDavid Lyon
Ā 
Quality of Analytical Procedures
Quality of Analytical ProceduresQuality of Analytical Procedures
Quality of Analytical ProceduresBrendon Naicker
Ā 
Calibration and Qualification of Analytical Instruments
Calibration and Qualification of Analytical InstrumentsCalibration and Qualification of Analytical Instruments
Calibration and Qualification of Analytical InstrumentsISF COLLEGE OF PHARMACY MOGA
Ā 
Calibration of Instruments
Calibration of InstrumentsCalibration of Instruments
Calibration of Instrumentskaroline Enoch
Ā 
THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST SYSTEM
THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST SYSTEMTHE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST SYSTEM
THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST SYSTEMieijjournal
Ā 
Qualification of gc equipment by manoj kumar
Qualification of gc equipment by manoj kumarQualification of gc equipment by manoj kumar
Qualification of gc equipment by manoj kumarhimaja donthula
Ā 
inspection , test and measurement
inspection , test and measurementinspection , test and measurement
inspection , test and measurementtanvikumbhar
Ā 
Method Validation - Repeatability
Method Validation - RepeatabilityMethod Validation - Repeatability
Method Validation - Repeatabilitylabgo
Ā 
Qualification of analytical instruments
Qualification of analytical instruments Qualification of analytical instruments
Qualification of analytical instruments PUNEET NIRMAL
Ā 
Qualification of High Performance Liquid Chromatography(HPLC)
Qualification of High Performance Liquid Chromatography(HPLC)Qualification of High Performance Liquid Chromatography(HPLC)
Qualification of High Performance Liquid Chromatography(HPLC)PRAVADA
Ā 
Statistical process control
Statistical process controlStatistical process control
Statistical process controlANOOPA NARAYANAN
Ā 
Calibration and validation of analytical instruments
Calibration and validation of analytical instrumentsCalibration and validation of analytical instruments
Calibration and validation of analytical instrumentsSolairajan A
Ā 
Practical Tools for Measurement Systems Analysis
Practical Tools for Measurement Systems AnalysisPractical Tools for Measurement Systems Analysis
Practical Tools for Measurement Systems AnalysisGabor Szabo, CQE
Ā 

What's hot (20)

Calabration principles-chapter1
Calabration principles-chapter1Calabration principles-chapter1
Calabration principles-chapter1
Ā 
calibration of analytical instruments
calibration of analytical instruments calibration of analytical instruments
calibration of analytical instruments
Ā 
Ilac g24 edition 2007 (e)
Ilac g24 edition 2007 (e)Ilac g24 edition 2007 (e)
Ilac g24 edition 2007 (e)
Ā 
Quality assurance part_2
Quality assurance part_2Quality assurance part_2
Quality assurance part_2
Ā 
Analytical Method Validation basics by Dr. A. Amsavel
Analytical Method Validation  basics by Dr. A. AmsavelAnalytical Method Validation  basics by Dr. A. Amsavel
Analytical Method Validation basics by Dr. A. Amsavel
Ā 
aa-automation-apc-complex-industrial-processes
aa-automation-apc-complex-industrial-processesaa-automation-apc-complex-industrial-processes
aa-automation-apc-complex-industrial-processes
Ā 
Quality of Analytical Procedures
Quality of Analytical ProceduresQuality of Analytical Procedures
Quality of Analytical Procedures
Ā 
Calibration and Qualification of Analytical Instruments
Calibration and Qualification of Analytical InstrumentsCalibration and Qualification of Analytical Instruments
Calibration and Qualification of Analytical Instruments
Ā 
Calibration of Instruments
Calibration of InstrumentsCalibration of Instruments
Calibration of Instruments
Ā 
THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST SYSTEM
THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST SYSTEMTHE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST SYSTEM
THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST SYSTEM
Ā 
Qualification of gc equipment by manoj kumar
Qualification of gc equipment by manoj kumarQualification of gc equipment by manoj kumar
Qualification of gc equipment by manoj kumar
Ā 
inspection , test and measurement
inspection , test and measurementinspection , test and measurement
inspection , test and measurement
Ā 
Method Validation - Repeatability
Method Validation - RepeatabilityMethod Validation - Repeatability
Method Validation - Repeatability
Ā 
Qualification of analytical instruments
Qualification of analytical instruments Qualification of analytical instruments
Qualification of analytical instruments
Ā 
Calibration
CalibrationCalibration
Calibration
Ā 
Qualification of High Performance Liquid Chromatography(HPLC)
Qualification of High Performance Liquid Chromatography(HPLC)Qualification of High Performance Liquid Chromatography(HPLC)
Qualification of High Performance Liquid Chromatography(HPLC)
Ā 
Statistical process control
Statistical process controlStatistical process control
Statistical process control
Ā 
Calibration and validation of analytical instruments
Calibration and validation of analytical instrumentsCalibration and validation of analytical instruments
Calibration and validation of analytical instruments
Ā 
Practical Tools for Measurement Systems Analysis
Practical Tools for Measurement Systems AnalysisPractical Tools for Measurement Systems Analysis
Practical Tools for Measurement Systems Analysis
Ā 
Spc
SpcSpc
Spc
Ā 

Similar to Tqa

Interactive GR&R Self-teach Presentation-1
Interactive GR&R Self-teach Presentation-1Interactive GR&R Self-teach Presentation-1
Interactive GR&R Self-teach Presentation-1Kea Jolicoeur
Ā 
datacolor spectrophotometer working procedure
datacolor spectrophotometer working procedure datacolor spectrophotometer working procedure
datacolor spectrophotometer working procedure Epyllion Group ( Textile )
Ā 
Azure machine learning
Azure machine learningAzure machine learning
Azure machine learningSimone Caldaro
Ā 
TQM-Unit 3-7-1 tools of quality-New.pptx
TQM-Unit 3-7-1 tools of quality-New.pptxTQM-Unit 3-7-1 tools of quality-New.pptx
TQM-Unit 3-7-1 tools of quality-New.pptxTamilselvan S
Ā 
Quality_Control_Tools.ppt
Quality_Control_Tools.pptQuality_Control_Tools.ppt
Quality_Control_Tools.pptMurali Sama rao
Ā 
Practical Tools for Measurement Systems Analysis
Practical Tools for Measurement Systems AnalysisPractical Tools for Measurement Systems Analysis
Practical Tools for Measurement Systems AnalysisGabor Szabo, CQE
Ā 
Parameters in Tableau
Parameters in TableauParameters in Tableau
Parameters in TableauKanika Nagpal
Ā 
GCSE ICT TESTING
GCSE ICT TESTING GCSE ICT TESTING
GCSE ICT TESTING morgan98
Ā 
SHORT CIRCUIT analysis
SHORT CIRCUIT analysisSHORT CIRCUIT analysis
SHORT CIRCUIT analysisArvind Akkanna
Ā 
03&04 SPC NOTES.pptx
03&04 SPC NOTES.pptx03&04 SPC NOTES.pptx
03&04 SPC NOTES.pptxartem48853
Ā 
Central Composite Design
Central Composite DesignCentral Composite Design
Central Composite DesignRuchir Shah
Ā 
Soft And Handling
Soft And HandlingSoft And Handling
Soft And Handlinghiratufail
Ā 
The 7 basic quality tools through minitab 18
The 7 basic quality tools through minitab 18The 7 basic quality tools through minitab 18
The 7 basic quality tools through minitab 18RAMAR BOSE
Ā 
Seven quality tools
Seven quality toolsSeven quality tools
Seven quality toolsPrateek Nigam
Ā 
Advanced Filter Concepts in MS-Excel
Advanced Filter Concepts in MS-ExcelAdvanced Filter Concepts in MS-Excel
Advanced Filter Concepts in MS-ExcelP. SUNDARI ARUN
Ā 
Comparing Means in IBM SPSS Modeler.pptx
Comparing Means in IBM SPSS Modeler.pptxComparing Means in IBM SPSS Modeler.pptx
Comparing Means in IBM SPSS Modeler.pptxVersion 1 Analytics
Ā 

Similar to Tqa (20)

Interactive GR&R Self-teach Presentation-1
Interactive GR&R Self-teach Presentation-1Interactive GR&R Self-teach Presentation-1
Interactive GR&R Self-teach Presentation-1
Ā 
datacolor spectrophotometer working procedure
datacolor spectrophotometer working procedure datacolor spectrophotometer working procedure
datacolor spectrophotometer working procedure
Ā 
Azure machine learning
Azure machine learningAzure machine learning
Azure machine learning
Ā 
TQM-Unit 3-7-1 tools of quality-New.pptx
TQM-Unit 3-7-1 tools of quality-New.pptxTQM-Unit 3-7-1 tools of quality-New.pptx
TQM-Unit 3-7-1 tools of quality-New.pptx
Ā 
Quality_Control_Tools.ppt
Quality_Control_Tools.pptQuality_Control_Tools.ppt
Quality_Control_Tools.ppt
Ā 
Practical Tools for Measurement Systems Analysis
Practical Tools for Measurement Systems AnalysisPractical Tools for Measurement Systems Analysis
Practical Tools for Measurement Systems Analysis
Ā 
Parameters in Tableau
Parameters in TableauParameters in Tableau
Parameters in Tableau
Ā 
GCSE ICT TESTING
GCSE ICT TESTING GCSE ICT TESTING
GCSE ICT TESTING
Ā 
SHORT CIRCUIT analysis
SHORT CIRCUIT analysisSHORT CIRCUIT analysis
SHORT CIRCUIT analysis
Ā 
03&04 SPC NOTES.pptx
03&04 SPC NOTES.pptx03&04 SPC NOTES.pptx
03&04 SPC NOTES.pptx
Ā 
Central Composite Design
Central Composite DesignCentral Composite Design
Central Composite Design
Ā 
Soft And Handling
Soft And HandlingSoft And Handling
Soft And Handling
Ā 
mel705-15.ppt
mel705-15.pptmel705-15.ppt
mel705-15.ppt
Ā 
mel705-15.ppt
mel705-15.pptmel705-15.ppt
mel705-15.ppt
Ā 
The 7 basic quality tools through minitab 18
The 7 basic quality tools through minitab 18The 7 basic quality tools through minitab 18
The 7 basic quality tools through minitab 18
Ā 
Seven quality tools
Seven quality toolsSeven quality tools
Seven quality tools
Ā 
Six sigma
Six sigmaSix sigma
Six sigma
Ā 
Advanced Filter Concepts in MS-Excel
Advanced Filter Concepts in MS-ExcelAdvanced Filter Concepts in MS-Excel
Advanced Filter Concepts in MS-Excel
Ā 
Comparing Means in IBM SPSS Modeler.pptx
Comparing Means in IBM SPSS Modeler.pptxComparing Means in IBM SPSS Modeler.pptx
Comparing Means in IBM SPSS Modeler.pptx
Ā 
Testing
TestingTesting
Testing
Ā 

More from Gamal Abdel Hamid

More from Gamal Abdel Hamid (20)

Marketing
Marketing  Marketing
Marketing
Ā 
Think 3
Think 3Think 3
Think 3
Ā 
Think 2
Think 2Think 2
Think 2
Ā 
Think
ThinkThink
Think
Ā 
Intro. to PowerPoint
Intro. to PowerPointIntro. to PowerPoint
Intro. to PowerPoint
Ā 
Method development
Method developmentMethod development
Method development
Ā 
ICP - ICP/MS comparison
ICP - ICP/MS comparisonICP - ICP/MS comparison
ICP - ICP/MS comparison
Ā 
ICP / MS Technique
ICP / MS TechniqueICP / MS Technique
ICP / MS Technique
Ā 
HPLC System Selection
HPLC System SelectionHPLC System Selection
HPLC System Selection
Ā 
ICP / AAS Comparison
ICP / AAS ComparisonICP / AAS Comparison
ICP / AAS Comparison
Ā 
DMA Direct Mercury Analyzer
DMA  Direct Mercury AnalyzerDMA  Direct Mercury Analyzer
DMA Direct Mercury Analyzer
Ā 
UV / VIS
UV / VIS UV / VIS
UV / VIS
Ā 
Gas Analysis Using FTIR
Gas Analysis Using FTIRGas Analysis Using FTIR
Gas Analysis Using FTIR
Ā 
FTIR software
FTIR softwareFTIR software
FTIR software
Ā 
Microwave digestion
Microwave digestionMicrowave digestion
Microwave digestion
Ā 
Flash EA 1112 , Organic Elemental Analyzer
Flash EA 1112 , Organic Elemental AnalyzerFlash EA 1112 , Organic Elemental Analyzer
Flash EA 1112 , Organic Elemental Analyzer
Ā 
Hazardous chemicals handling
Hazardous chemicals handlingHazardous chemicals handling
Hazardous chemicals handling
Ā 
Forensic laboratory
Forensic laboratoryForensic laboratory
Forensic laboratory
Ā 
Lead acid battery recycling. Environ. control
 Lead acid battery recycling. Environ. control Lead acid battery recycling. Environ. control
Lead acid battery recycling. Environ. control
Ā 
ISO 9001
ISO 9001ISO 9001
ISO 9001
Ā 

Recently uploaded

%in kempton park+277-882-255-28 abortion pills for sale in kempton park
%in kempton park+277-882-255-28 abortion pills for sale in kempton park %in kempton park+277-882-255-28 abortion pills for sale in kempton park
%in kempton park+277-882-255-28 abortion pills for sale in kempton park masabamasaba
Ā 
CHEAP Call Girls in Pushp Vihar (-DELHI )šŸ” 9953056974šŸ”(=)/CALL GIRLS SERVICE
CHEAP Call Girls in Pushp Vihar (-DELHI )šŸ” 9953056974šŸ”(=)/CALL GIRLS SERVICECHEAP Call Girls in Pushp Vihar (-DELHI )šŸ” 9953056974šŸ”(=)/CALL GIRLS SERVICE
CHEAP Call Girls in Pushp Vihar (-DELHI )šŸ” 9953056974šŸ”(=)/CALL GIRLS SERVICE9953056974 Low Rate Call Girls In Saket, Delhi NCR
Ā 
VTU technical seminar 8Th Sem on Scikit-learn
VTU technical seminar 8Th Sem on Scikit-learnVTU technical seminar 8Th Sem on Scikit-learn
VTU technical seminar 8Th Sem on Scikit-learnAmarnathKambale
Ā 
%in Harare+277-882-255-28 abortion pills for sale in Harare
%in Harare+277-882-255-28 abortion pills for sale in Harare%in Harare+277-882-255-28 abortion pills for sale in Harare
%in Harare+277-882-255-28 abortion pills for sale in Hararemasabamasaba
Ā 
%+27788225528 love spells in new york Psychic Readings, Attraction spells,Bri...
%+27788225528 love spells in new york Psychic Readings, Attraction spells,Bri...%+27788225528 love spells in new york Psychic Readings, Attraction spells,Bri...
%+27788225528 love spells in new york Psychic Readings, Attraction spells,Bri...masabamasaba
Ā 
%+27788225528 love spells in Atlanta Psychic Readings, Attraction spells,Brin...
%+27788225528 love spells in Atlanta Psychic Readings, Attraction spells,Brin...%+27788225528 love spells in Atlanta Psychic Readings, Attraction spells,Brin...
%+27788225528 love spells in Atlanta Psychic Readings, Attraction spells,Brin...masabamasaba
Ā 
Microsoft AI Transformation Partner Playbook.pdf
Microsoft AI Transformation Partner Playbook.pdfMicrosoft AI Transformation Partner Playbook.pdf
Microsoft AI Transformation Partner Playbook.pdfWilly Marroquin (WillyDevNET)
Ā 
Chinsurah Escorts ā˜Žļø8617697112 Starting From 5K to 15K High Profile Escorts ...
Chinsurah Escorts ā˜Žļø8617697112  Starting From 5K to 15K High Profile Escorts ...Chinsurah Escorts ā˜Žļø8617697112  Starting From 5K to 15K High Profile Escorts ...
Chinsurah Escorts ā˜Žļø8617697112 Starting From 5K to 15K High Profile Escorts ...Nitya salvi
Ā 
%in tembisa+277-882-255-28 abortion pills for sale in tembisa
%in tembisa+277-882-255-28 abortion pills for sale in tembisa%in tembisa+277-882-255-28 abortion pills for sale in tembisa
%in tembisa+277-882-255-28 abortion pills for sale in tembisamasabamasaba
Ā 
Software Quality Assurance Interview Questions
Software Quality Assurance Interview QuestionsSoftware Quality Assurance Interview Questions
Software Quality Assurance Interview QuestionsArshad QA
Ā 
TECUNIQUE: Success Stories: IT Service provider
TECUNIQUE: Success Stories: IT Service providerTECUNIQUE: Success Stories: IT Service provider
TECUNIQUE: Success Stories: IT Service providermohitmore19
Ā 
%in kaalfontein+277-882-255-28 abortion pills for sale in kaalfontein
%in kaalfontein+277-882-255-28 abortion pills for sale in kaalfontein%in kaalfontein+277-882-255-28 abortion pills for sale in kaalfontein
%in kaalfontein+277-882-255-28 abortion pills for sale in kaalfonteinmasabamasaba
Ā 
SHRMPro HRMS Software Solutions Presentation
SHRMPro HRMS Software Solutions PresentationSHRMPro HRMS Software Solutions Presentation
SHRMPro HRMS Software Solutions PresentationShrmpro
Ā 
Shapes for Sharing between Graph Data SpacesĀ - and Epistemic Querying of RDF-...
Shapes for Sharing between Graph Data SpacesĀ - and Epistemic Querying of RDF-...Shapes for Sharing between Graph Data SpacesĀ - and Epistemic Querying of RDF-...
Shapes for Sharing between Graph Data SpacesĀ - and Epistemic Querying of RDF-...Steffen Staab
Ā 
OpenChain - The Ramifications of ISO/IEC 5230 and ISO/IEC 18974 for Legal Pro...
OpenChain - The Ramifications of ISO/IEC 5230 and ISO/IEC 18974 for Legal Pro...OpenChain - The Ramifications of ISO/IEC 5230 and ISO/IEC 18974 for Legal Pro...
OpenChain - The Ramifications of ISO/IEC 5230 and ISO/IEC 18974 for Legal Pro...Shane Coughlan
Ā 
%+27788225528 love spells in Vancouver Psychic Readings, Attraction spells,Br...
%+27788225528 love spells in Vancouver Psychic Readings, Attraction spells,Br...%+27788225528 love spells in Vancouver Psychic Readings, Attraction spells,Br...
%+27788225528 love spells in Vancouver Psychic Readings, Attraction spells,Br...masabamasaba
Ā 
%in Durban+277-882-255-28 abortion pills for sale in Durban
%in Durban+277-882-255-28 abortion pills for sale in Durban%in Durban+277-882-255-28 abortion pills for sale in Durban
%in Durban+277-882-255-28 abortion pills for sale in Durbanmasabamasaba
Ā 
Right Money Management App For Your Financial Goals
Right Money Management App For Your Financial GoalsRight Money Management App For Your Financial Goals
Right Money Management App For Your Financial GoalsJhone kinadey
Ā 
%in Hazyview+277-882-255-28 abortion pills for sale in Hazyview
%in Hazyview+277-882-255-28 abortion pills for sale in Hazyview%in Hazyview+277-882-255-28 abortion pills for sale in Hazyview
%in Hazyview+277-882-255-28 abortion pills for sale in Hazyviewmasabamasaba
Ā 
Unlocking the Future of AI Agents with Large Language Models
Unlocking the Future of AI Agents with Large Language ModelsUnlocking the Future of AI Agents with Large Language Models
Unlocking the Future of AI Agents with Large Language Modelsaagamshah0812
Ā 

Recently uploaded (20)

%in kempton park+277-882-255-28 abortion pills for sale in kempton park
%in kempton park+277-882-255-28 abortion pills for sale in kempton park %in kempton park+277-882-255-28 abortion pills for sale in kempton park
%in kempton park+277-882-255-28 abortion pills for sale in kempton park
Ā 
CHEAP Call Girls in Pushp Vihar (-DELHI )šŸ” 9953056974šŸ”(=)/CALL GIRLS SERVICE
CHEAP Call Girls in Pushp Vihar (-DELHI )šŸ” 9953056974šŸ”(=)/CALL GIRLS SERVICECHEAP Call Girls in Pushp Vihar (-DELHI )šŸ” 9953056974šŸ”(=)/CALL GIRLS SERVICE
CHEAP Call Girls in Pushp Vihar (-DELHI )šŸ” 9953056974šŸ”(=)/CALL GIRLS SERVICE
Ā 
VTU technical seminar 8Th Sem on Scikit-learn
VTU technical seminar 8Th Sem on Scikit-learnVTU technical seminar 8Th Sem on Scikit-learn
VTU technical seminar 8Th Sem on Scikit-learn
Ā 
%in Harare+277-882-255-28 abortion pills for sale in Harare
%in Harare+277-882-255-28 abortion pills for sale in Harare%in Harare+277-882-255-28 abortion pills for sale in Harare
%in Harare+277-882-255-28 abortion pills for sale in Harare
Ā 
%+27788225528 love spells in new york Psychic Readings, Attraction spells,Bri...
%+27788225528 love spells in new york Psychic Readings, Attraction spells,Bri...%+27788225528 love spells in new york Psychic Readings, Attraction spells,Bri...
%+27788225528 love spells in new york Psychic Readings, Attraction spells,Bri...
Ā 
%+27788225528 love spells in Atlanta Psychic Readings, Attraction spells,Brin...
%+27788225528 love spells in Atlanta Psychic Readings, Attraction spells,Brin...%+27788225528 love spells in Atlanta Psychic Readings, Attraction spells,Brin...
%+27788225528 love spells in Atlanta Psychic Readings, Attraction spells,Brin...
Ā 
Microsoft AI Transformation Partner Playbook.pdf
Microsoft AI Transformation Partner Playbook.pdfMicrosoft AI Transformation Partner Playbook.pdf
Microsoft AI Transformation Partner Playbook.pdf
Ā 
Chinsurah Escorts ā˜Žļø8617697112 Starting From 5K to 15K High Profile Escorts ...
Chinsurah Escorts ā˜Žļø8617697112  Starting From 5K to 15K High Profile Escorts ...Chinsurah Escorts ā˜Žļø8617697112  Starting From 5K to 15K High Profile Escorts ...
Chinsurah Escorts ā˜Žļø8617697112 Starting From 5K to 15K High Profile Escorts ...
Ā 
%in tembisa+277-882-255-28 abortion pills for sale in tembisa
%in tembisa+277-882-255-28 abortion pills for sale in tembisa%in tembisa+277-882-255-28 abortion pills for sale in tembisa
%in tembisa+277-882-255-28 abortion pills for sale in tembisa
Ā 
Software Quality Assurance Interview Questions
Software Quality Assurance Interview QuestionsSoftware Quality Assurance Interview Questions
Software Quality Assurance Interview Questions
Ā 
TECUNIQUE: Success Stories: IT Service provider
TECUNIQUE: Success Stories: IT Service providerTECUNIQUE: Success Stories: IT Service provider
TECUNIQUE: Success Stories: IT Service provider
Ā 
%in kaalfontein+277-882-255-28 abortion pills for sale in kaalfontein
%in kaalfontein+277-882-255-28 abortion pills for sale in kaalfontein%in kaalfontein+277-882-255-28 abortion pills for sale in kaalfontein
%in kaalfontein+277-882-255-28 abortion pills for sale in kaalfontein
Ā 
SHRMPro HRMS Software Solutions Presentation
SHRMPro HRMS Software Solutions PresentationSHRMPro HRMS Software Solutions Presentation
SHRMPro HRMS Software Solutions Presentation
Ā 
Shapes for Sharing between Graph Data SpacesĀ - and Epistemic Querying of RDF-...
Shapes for Sharing between Graph Data SpacesĀ - and Epistemic Querying of RDF-...Shapes for Sharing between Graph Data SpacesĀ - and Epistemic Querying of RDF-...
Shapes for Sharing between Graph Data SpacesĀ - and Epistemic Querying of RDF-...
Ā 
OpenChain - The Ramifications of ISO/IEC 5230 and ISO/IEC 18974 for Legal Pro...
OpenChain - The Ramifications of ISO/IEC 5230 and ISO/IEC 18974 for Legal Pro...OpenChain - The Ramifications of ISO/IEC 5230 and ISO/IEC 18974 for Legal Pro...
OpenChain - The Ramifications of ISO/IEC 5230 and ISO/IEC 18974 for Legal Pro...
Ā 
%+27788225528 love spells in Vancouver Psychic Readings, Attraction spells,Br...
%+27788225528 love spells in Vancouver Psychic Readings, Attraction spells,Br...%+27788225528 love spells in Vancouver Psychic Readings, Attraction spells,Br...
%+27788225528 love spells in Vancouver Psychic Readings, Attraction spells,Br...
Ā 
%in Durban+277-882-255-28 abortion pills for sale in Durban
%in Durban+277-882-255-28 abortion pills for sale in Durban%in Durban+277-882-255-28 abortion pills for sale in Durban
%in Durban+277-882-255-28 abortion pills for sale in Durban
Ā 
Right Money Management App For Your Financial Goals
Right Money Management App For Your Financial GoalsRight Money Management App For Your Financial Goals
Right Money Management App For Your Financial Goals
Ā 
%in Hazyview+277-882-255-28 abortion pills for sale in Hazyview
%in Hazyview+277-882-255-28 abortion pills for sale in Hazyview%in Hazyview+277-882-255-28 abortion pills for sale in Hazyview
%in Hazyview+277-882-255-28 abortion pills for sale in Hazyview
Ā 
Unlocking the Future of AI Agents with Large Language Models
Unlocking the Future of AI Agents with Large Language ModelsUnlocking the Future of AI Agents with Large Language Models
Unlocking the Future of AI Agents with Large Language Models
Ā 

Tqa

  • 2. Gamal A. Hamid Contents ā€¢ Introduction ā€¢ Software contents o Menu Bar o Tool Bar o Parameter Tabs o Action & Option buttons ā€¢ Getting started 2
  • 4. Gamal A. Hamid TQA Software ā€¢ TQ Analyst is a standard Windows application . ā€¢ The software offers a complete selection of qualitative and quantitative analytical techniques. ā€¢ It contains all of the algorithms that are typically used for calculating component concentrations and classifying spectra based on a set of standards. 4
  • 5. Gamal A. Hamid Quantitative Analysis ā€¢ Infrared spectroscopy is most often used for qualitative identification. ā€¢ An unknown material can be determined by comparing the infrared spectrum acquired on this sample to the spectra of known compounds. ā€¢ Analysis of the infrared spectral band intensities as a function of solute concentration provides a straightforward means for determining the concentration mixture components. 5
  • 7. Gamal A. Hamid Software Contents The main components of software :- I. Menu Bar II. Tool Bar III. Parameter Tab IV. Action Buttons V. Option Buttons 7
  • 9. Gamal A. Hamid I. Menu Bar ā€¢ The menus provide useful commands for working with method files and spectral data. ā€¢ You will also find a menu of diagnostic commands that can be used to evaluate a method as you develop it. ā€¢ Within each menu, the commands are grouped according to their related functions 9
  • 10. Gamal A. Hamid 1. File Menu ā€¢ Displays the commands used to create, open, save, and print methods from TQ Analyst and to save a TQ Analyst spectrum in a file on your disk. ā€¢ It also explains how to open and run a completed TQ Analyst method from other applications and to move method files from one computer to another. 10
  • 11. Gamal A. Hamid 2. Edit Menu ā€¢ Default Method Path to specify a default directory path for opening and saving. ā€¢ Default Spectrum Path to specify a default directory path for opening and saving spectra ā€¢ Options You can customize the way TQ Analyst displays certain windows and dialog boxes by setting options. ā€¢ Edit Menu lets you create custom Menu containing buttons for quickly initiating commands. 11
  • 12. Gamal A. Hamid 3. View Menu 12 ā€¢ Display Setup to specify how spectra to be displayed ā€¢ Stacking spectra is useful when you are comparing spectra that are significantly different. ā€¢ Hide Spectra to hide the selected spectra from view. ā€¢ Full Scale to adjust the vertical scale of the spectra . ā€¢ Common Scale to display all the spectra using the same Y-axis ā€¢ Match Scale ,All the spectra in the window are displayed using the Y-axis limits . ā€¢ Offset Scale to display the spectra vertically offset from each other, Separating the spectra.
  • 13. Gamal A. Hamid View Menu ā€¢ Display Limits to specify the X-axis and Y-axis display limits. ā€¢ Automatic Full Scale automatically displays the spectra full. ā€¢ Absorbance at a frequency is defined by the equation A = log(100/%T) ā€¢ Transmittance IR energy transmitted through the sample. %T = (S/B)*100 where S is IR intensity B is IR intensity without a sample in place (background). ā€¢ Retrieve Interferogram to display the interferogram for the selected spectrum in the active spectral window. ā€¢ Reprocess to transform the interferogram data for the selected spectra using different transformation parameter. 13
  • 14. Gamal A. Hamid 4. Diagnostic Menu ā€¢ The Eigenanalysis to start the Eigenanalysis diagnostic routine. ā€¢ The Principal Component Spectra to start the Principal Component Spectra diagnostic routine. ā€¢ The Pairwise Concentration to start the Pairwise Concentration diagnostic routine. ā€¢ The Spectrum Outlier to start the Spectrum Outlier diagnostic routine. ā€¢ The Pure Component Spectra to display the synthetic pure component spectrum for each component in a quantitative method and one pathlength spectrum. 14
  • 15. Gamal A. Hamid Diagnostic Menu 2 ā€¢ The Statistical Spectra to generate a series of synthetic spectra that illustrate the variation present in the standards and, for quantitative methods, the spectral regions that correlate with changes in component concentration. ā€¢ Select Standards if you need help choosing appropriate standards for a quantitative. ā€¢ The Cross Validation to start the Cross Validation diagnostic routine. ā€¢ The External Validation to start the External Validation diagnostic routine. 15
  • 16. Gamal A. Hamid Diagnostic Menu 3 ā€¢ The Residual Spectra to quantify a spectrum using the active method and then display the residual spectrum or spectra for the spectrum that was quantified. ā€¢ The Multiple Quantify to quantify two or more spectra and store the calculated results in a format that is accessible to other applications. ā€¢ The Multiple Summary to quantify two or more spectra and store a summary of the results in a format that is accessible to other applications, ā€¢ The Quantify Sequence or Map calculate component concentration values from a sequence (*.srs) or map (*.map) file. 16
  • 17. Gamal A. Hamid Diagnostic Menu 4 ā€¢ The Principal Component Scores to start the Principal Component Scores diagnostic routine. ā€¢ The PRESS to start the PRESS diagnostic routine. ā€¢ The Factor Loading to start the Factor Loading diagnostic routine. ā€¢ The Leverage to start the Leverage diagnostic routine. ā€¢ The Loading Spectra to start the Loading Spectra diagnostic routine. 17
  • 18. Gamal A. Hamid 5. Window Menu and Help ā€¢ The Window menu show the names of the TQ Analyst windows that are currently open and allow you to make an open window active. ā€¢ Use this command to display the version number for your TQ Analyst software 18
  • 19. Gamal A. Hamid II. Tool Bar The toolbar allows you to perform operations with the current method. 1. Calibrate 2. Quantify 3. Explain 4. Performance Index 19
  • 20. Gamal A. Hamid 1. Calibrate ā€¢ To analyze a set of calibration standards in order to calculate a method model for predicting component concentrations in unknown samples. ā€¢ The first time you calibrate a method, the software calculates a performance index, which appears next to the Close button on the toolbar. ā€¢ If you change the method and then recalibrate 20
  • 21. Gamal A. Hamid 2. Quantify ā€¢ Using the calibration method to analyze the unknown samples . 21
  • 22. Gamal A. Hamid 3. Explain TQ Analyst Explain Help ā€¢ Explain Help for TQ Analyst tab features ā€¢ Explain Help for TQ Analyst Diagnostics ā€¢ Explain Help for the Region Selection task window ā€¢ Explain Help for the Corrections task window ā€¢ Explain Help for the Calibration Results window 22
  • 23. Gamal A. Hamid 4. Performance Index ā€¢ The performance index for the previous calibration as well as the index for the new calibration. ā€¢ If your method has no validation standards, the symbol "N/A," meaning "not available," is displayed in the toolbar instead of a performance index. ā€¢ The indicator to the right of the performance index tells whether the selected method is calibrated. ā€¢ If the method has never been calibrated, the bar is red and the message reads "uncalibrated." After the first calibration, the bar turns green and the "calibrated" message appears. 23
  • 24. Gamal A. Hamid III. Parameter Tabs ā€¢ Method parameters are grouped by function. ā€¢ Each group of parameters is contained on a file card which has a tab that is always visible at the top of the method window. ā€¢ To display a group of parameters, click the corresponding tab. 24
  • 25. Gamal A. Hamid IV. Action Buttons ā€¢ These buttons, called "action buttons," allow you to perform tasks related to the selected tab. ā€¢ For example, the "Suggest" button shown in the illustration below may be used to help you set the Analysis Type parameter on the description tab. 25
  • 26. Gamal A. Hamid V. Option Buttons ā€¢ Some parameters, such as the Analysis Type and Pathlength Type, provide a group of option buttons and allow you to select only one of the available options. ā€¢ You can select an option from a group of option buttons by using the mouse to click the corresponding button. 26
  • 27. Gamal A. Hamid 1. Description Tab ā€¢ Use the parameters on this tab to enter general information about your method. ā€¢ A method can be described by its title, developer, revision number, revision date, and analysis type. ā€¢ If you need help choosing the proper analysis type for your samples, use the Analysis Type wizard. To start the wizard, click the Suggest Analysis Type button on this tab. ā€¢ The Description tab is displayed for all analysis types. ā€¢ The information on this tab is saved automatically when you save the active method. 27
  • 28. Gamal A. Hamid Description Action Buttons ā€¢ the "Suggest" button used to help you set the Analysis Type parameter on the Description tab. ā€¢ If you need help choosing the analysis type, use the Analysis Type wizard. To start the wizard, click the Suggest Analysis Type button at the top of this tab. ā€¢ Display the How To window if you are looking for quick instructions on how to use the tools in this window to complete a task. a help window that contains information about creating TQ Analyst methods is displayed on the screen. 28
  • 29. Gamal A. Hamid Description Options Buttons ā€¢ The Analysis Type parameter defines the type of results the method will produce when you use it to analyze an unknown sample spectrum and the algorithm that will be used for the analysis. ā€¢ There are three basic types of analyses you can do with TQ Analyst: 29
  • 30. Gamal A. Hamid Analysis Type 1. Quantitative Analysis ā€¢ Measuring component amounts or concentrations in a sample mixture. 2. Classification ā€¢ Classifying an unknown sample spectrum by finding the spectrum or group of spectra that most closely match the sample spectrum or by verifying that the sample spectrum is similar to the spectra in a specified group. 3. Measurement ā€¢ Measuring peak heights, peak areas, peak locations, or peak widths in a sample spectrum or calculating the ratio of two measured peaks. 30
  • 31. Gamal A. Hamid 2. Pathlength Tab ā€¢ Sample pathlength is important to quantitative analyses because the intensities of the peaks in a sample spectrum are determined by the thickness as well as the composition of the sample. ā€¢ Pathlength is important to a spectral measurement analysis only when the measurement data are used for quantitative or classification purposes. 31
  • 32. Gamal A. Hamid Pathlength Action Buttons ā€¢ Use Suggest Pathlength Type if you are not familiar with the pathlength treatments provided in TQ Analyst or need help deciding which treatment would work best for the samples. ā€¢ Use the Advanced button to access the temperature/pressure and dilution/extraction features of TQ Analyst software. ā€¢ Use Edit Region when you need to specify or adjust the pathlength peak for the Internal Reference or Peak Ratio pathlength type. 32
  • 33. Gamal A. Hamid Pathlength Option Buttons ā€¢ Undecided allows you to postpone choosing the pathlength type. ā€¢ You cannot calibrate a method when the pathlength type is set to Undecided. ā€¢ Constant type which uses one pathlength value to calculate component amounts or concentrations in all of the samples to be analyzed. ā€¢ Known an option for pathlength type if you are analyzing samples that have different but known thicknesses. 33
  • 34. Gamal A. Hamid 3. Components Tab ā€¢ The components will be listed in a table. ā€¢ Each component is described by its name and an abbreviated name as well as the number of digits and the unit which will be used to report its concentration. ā€¢ Concentration limits, such as analysis limits and acceptance limits, may also be specified for each component. ā€¢ The Components tab is displayed only when the Analysis Type parameter on the Description tab is set to a quantitative analysis type, 34
  • 35. Gamal A. Hamid Components Action Buttons ā€¢ This button starts the Assess Feasibility wizard to help you determine if there is sufficient variability in your sample data that correlates with differences in sample composition ā€¢ Use Assess Feasibility to quickly determine if it is possible to create a calibration model that can calculate the concentrations of the components you want to measure. 35
  • 36. Gamal A. Hamid Components Option Buttons ā€¢ Concentration / Error limits, specify analysis limits for each component in the method. ā€¢ Use Concentration Constraints option if you know all the components in your sample and want their predicted concentrations to sum to a 100%. ā€¢ Use Component Interaction to indicate whether you expect any interactions between the components you want to measure. ā€¢ Composite Components is an additional method component that is computed from the results for one or more measured components. 36
  • 37. Gamal A. Hamid 4. Standards Tab ā€¢ Use the parameters on this tab to describe the standards that will be used to calibrate, validate, or correct the active method. ā€¢ The standards will be listed in a table. ā€¢ Each standard is described by its title and usage. ā€¢ Some analysis types require additional information for each standard, such as the concentrations or amounts of the components the standard contains or the class the standard belongs to. ā€¢ The Standards tab is always displayed unless the Analysis Type parameter on the Description tab is set to Measurement Only. 37
  • 38. Gamal A. Hamid Standards Action Buttons ā€¢ Suggest Standards wizard to help you select the number and component concentrations of the standards needed to calibrate and validate a quantitative method. ā€¢ Evaluate Standards wizard to determine whether the number and component conc. of the standards are appropriate for the components that are specified in the method. ā€¢ Open Standard to select a spectral data file to use as a standard in the active method. ā€¢ View Standards to display the spectra of selected standards in your method. ā€¢ Sort Standards to rearrange the entries in the Standards table. ā€¢ Ignore Missing Data to reassign to Ignore the usage of any method standards that contain the PLS missing data indicator value. 38
  • 39. Gamal A. Hamid Standards Option Buttons ā€¢ Show Spectrum Title ,File Names to specify how the standards will be listed in the Standards table and in other tables within the TQ Analyst software. You may list the standards by their file names, their titles, or both. ā€¢ Restrict Y-axis Range to restrict the analysis of your sample spectra to a specified Y- axis range. 39
  • 40. Gamal A. Hamid 5. Spectra Tab ā€¢ Format for spectral data and to apply processing operations to the data, such as subtraction, smoothing, and baseline correction. ā€¢ The corrections may be applied to the spectra of the method standards as well as to any sample spectra you use the method to analyze. ā€¢ If you want to specify more than one processing step, we recommend setting them up in this order: o Spectral Subtraction, o Data Format, o Smoothing, o Multipoint Baseline Correction. 40
  • 41. Gamal A. Hamid Spectra Action Buttons ā€¢ View Standards button on this tab to display the selected standards before and after the data have been processed. ā€¢ View Standards button on the Spectra tab to see the effects of a single processing sequence, such as smoothing, derivatives, or multi-point baseline correction, on the selected standards. 41
  • 42. Gamal A. Hamid Spectra Option Buttons ā€¢ Data Format to select a format for the spectral data you want to analyze. ā€œfirst or second derivative spectraā€. ā€¢ Spectral Subtraction allows to set up automatic subtraction for the spectra used with this method. Automatic subtraction subtracts a reference spectrum from the spectrum of each unknown sample. ā€¢ Multipoint Baseline Correction to turn on Multipoint baseline correction and specify what kind of correction will be used. 42
  • 43. Gamal A. Hamid 6. Regions Tab ā€¢ The parameters on this tab to identify the spectral peaks or regions ā€¢ Each region is described by its index number, measurement type, measurement location, baseline measurement type, and the locations of the baseline points. ā€¢ If you are creating a quantitative method, choosing regions that are appropriate for the selected analysis type and that correlate best with component concentrations. ā€¢ Once the regions are selected, several iterations of calibrating the method and refining the region limits, the measurement type, or the baseline points may be required in order to achieve accurate quantitative results. 43
  • 44. Gamal A. Hamid Regions Action Buttons ā€¢ The Suggest Regions to starts the Regions wizard to help you select the spectral region or regions that correlate best with the component. ā€¢ The Edit Regions to choose the proper region limits and baseline points when you can see the spectra of the standards. ā€¢ using the Region Selection task window to specify regions rather than entering region limits and baseline points directly into the Regions table. 44
  • 45. Gamal A. Hamid 7. Corrections Tab ā€¢ Use Corrections to define a mathematical equation which will attempt to correct a method's calibrated model for nonlinearity or bias. ā€¢ Displayed only with quantitative method type (ACLS, CLS, SMLR, PLS, and PCR. ā€¢ There are two types of corrections you may specify: o Linearity corrections o Bias corrections. ā€¢ The specified correction will be applied to the values calculated by the calibrated method to bring them closer to the actual values. ā€¢ Each correction is described by its index number, component name, and the correction coefficients for each term in the equation for the correction curve. 45
  • 46. Gamal A. Hamid Corrections Action Buttons ā€¢ The Suggest Corrections starts the Corrections wizard to help you determine whether corrections are needed for the components in your method and, if so, the type and degree of correction you should use. ā€¢ The Edit Corrections to display the Corrections task window for editing the correction parameters for one or more components in your method. ā€¢ The Cross Corrections to access the features for setting up a cross correction in your method. 46
  • 47. Gamal A. Hamid Corrections Option Buttons ā€¢ The Method Correction to specify whether the active method will include a post-prediction correction. ā€¢ The Correction Standards to specify whether all of your component correction curves will be generated from a separate set of correction standards or from a combination of correction standards and calibration standards. 47
  • 48. Gamal A. Hamid 8. Report Tab ā€¢ Use the parameters on this tab to select the information you want to include in the sample reports and to turn TQ Analystā€™s sample checking features on and off. ā€¢ The Report tab is displayed for all method types. ā€¢ The information on this tab is saved automatically when you save the active method. 48
  • 49. Gamal A. Hamid Report Option Buttons 49
  • 50. Gamal A. Hamid Creating a Method 50
  • 51. Gamal A. Hamid Basic Types of Analyses Quantitative ā€¢ Measuring component concentrations in a sample mixture. Classification ā€¢ Classifying an unknown sample spectrum by finding the spectrum or group of spectra that most closely match the sample spectrum. Measurement ā€¢ Measuring peak heights or areas, peak locations, or peak widths in a sample spectrum or calculating the ratio of two measured peaks. 51
  • 52. Gamal A. Hamid Creating a Quantitative Analysis ā€¢ The File menu to create a new method window. ā€¢ The Save Method As command in the File menu to create a method file. ā€¢ The Description tab and enter a title for your method. Choose an option for the quantitative analysis options on the Description tab. 52
  • 53. Gamal A. Hamid 1. Quantitative Analysis ā€¢ Select the Simple Beerā€™s Law analysis type when each of the components you want to measure produces a unique peak in the spectrum of the sample mixture. ā€¢ Select the Classic least Squares CLS analysis type when each component you want to measure produces a peak or combination of peaks in the spectrum of the sample mixture, but the component peaks overlap significantly. 53
  • 54. Gamal A. Hamid 2. Pathlength ā€¢ The Pathlength tab and select an option for the Pathlength parameter. ā€¢ The Advanced button displays a window that allows you to access the temperature/pressure and dilution/extraction features of TQ Analyst. ā€¢ Select Constant pathlength type if you are using a sampling accessory that has a fixed pathlength, such as a liquid transmission cell. 54
  • 55. Gamal A. Hamid 3. Components ā€¢ the Components tab and specify the components you want to measure and the analysis limits for each component. 55
  • 56. Gamal A. Hamid 4. Standards ā€¢ Describe the standards that will be used to calibrate, validate. 56
  • 57. Gamal A. Hamid View Standards 57
  • 58. Gamal A. Hamid 5. Spectra ā€¢ Format for spectral data and to apply processing operations to the data, such as subtraction, smoothing, and baseline correction. ā€¢ The corrections may be applied to the spectra of the method standards as well as to any sample spectra you use the method to analyze. ā€¢ If you want to specify more than one processing step, we recommend setting them up in this order: o Spectral Subtraction, o Data Format, o Smoothing, o Multipoint Baseline Correction. 58
  • 59. Gamal A. Hamid 6. Regions ā€¢ The Regions tab to see the spectral peaks or regions 59
  • 60. Gamal A. Hamid 7. Calibrate ā€¢ Click the Calibrate button on the toolbar to calibrate your method. 60
  • 61. Gamal A. Hamid 8. Quantify 61
  • 62. Gamal A. Hamid 9. Report ā€¢ Click the Report tab and specify the information you want to include in your sample reports, including any spectrum or result warnings. 62
  • 63. Gamal A. Hamid 10. Save the method ā€¢ The Save Method command in the File menu to save your completed method. 63