2. 6th Floor Meeting Room 1 –
12 Pax Room
Requirements
Power
• 4 Power sockets behind TV
• 4 Power sockets under table
Network
• 2 Network ports behind TV
• 2 Network ports under table
• 1 Network port in the ceiling for the
Room Scheduler device
Microphone
• Ceiling packing to allow mounting of
ceiling mic
Ceiling Speakers
• Cutout hole in ceiling for speakers.
Dimensions will be provided.
Table Cubby
• 2 x Cutout hole in table for cubby.
Dimensions will be provided.
Cable Runs
• Path in the ceiling for cable run to
speakers
• Path under floor between TV and
cable Cubby
• Cable run along door frame for
Room scheduler device
Power
Network
Microphone
Ceiling speakers
Table Cubby
Path for cable runs
75”
TV
3. 6th Floor Meeting Room 2 –
10 Pax Room
Requirements
Power
• 4 Power sockets behind TV
• 4 Power sockets under table
Network
• 2 Network ports behind TV
• 2 Network ports under table
• 1 Network port in the ceiling for the
Room Scheduler device
Microphone
• Ceiling packing to allow mounting of
ceiling mic
Ceiling Speakers
• Cutout hole in ceiling for speakers.
Dimensions will be provided.
Table Cubby
• 2 x Cutout hole in table for cubby.
Dimensions will be provided.
Cable Runs
• Path in the ceiling for cable run to
speakers
• Path under floor between TV and
cable Cubby
• Cable run along door frame for
Room scheduler device
Power
Network
Microphone
Ceiling speakers
Table Cubby
Path for cable runs
65”
TV
4. 6th Floor Meeting Room 3 – 8
Pax Room
Requirements
Power
• 4 Power sockets behind TV
• 2 Power sockets under table
Network
• 2 Network ports behind TV
• 2 Network ports under table
• 1 Network port in the ceiling for the
Room Scheduler device
Microphone
• 2 Table mics, no action required
Ceiling Speakers
• 0 ceiling speakers, no action
required
Table Cubby
• 1 x Cutout hole in table for cubby.
Dimensions will be provided.
Cable Runs
• Path under floor between TV and
cable Cubby
• Cable run along door frame for
Room scheduler device
Power
Network
Microphone
Table Cubby
Path for cable runs
65”
TV
5. 6th Floor Meeting Room 4 – 6
Pax Room
Requirements
Power
• 4 Power sockets behind TV
• 2 Power sockets under table
Network
• 2 Network ports behind TV
• 2 Network ports under table
• 1 Network port in the ceiling for the
Room Scheduler device
Microphone
• 1 Table mic, no action required
Ceiling Speakers
• 0 ceiling speakers, no action
required
Table Cubby
• 1 x Cutout hole in table for cubby.
Dimensions will be provided.
Cable Runs
• Path under floor between TV and
cable Cubby
• Cable run along door frame for
Room scheduler device
Power
Network
Microphone
Table Cubby
Path for cable runs
65”
TV
6. 6th Floor Meeting Room 5 – 6
Pax Room
Requirements
Power
• 4 Power sockets behind TV
• 2 Power sockets under table
Network
• 2 Network ports behind TV
• 2 Network ports under table
• 1 Network port in the ceiling for the
Room Scheduler device
Microphone
• 1 Table mic, no action required
Ceiling Speakers
• 0 ceiling speakers, no action
required
Table Cubby
• 1 x Cutout hole in table for cubby.
Dimensions will be provided.
Cable Runs
• Path under floor between TV and
cable Cubby
• Cable run along door frame for
Room scheduler device
Power
Network
Microphone
Table Cubby
Path for cable runs
65”
TV
7. 6th Floor Collaboration Space 1
– 10 Pax Room
Requirements
Power
• 4 Power sockets behind TV
• 2 Power sockets under table
Network
• 2 Network ports behind TV
• 2 Network ports under table
Table Cubby
• 2 x Cutout hole in table for cubby’s.
Dimensions will be provided.
Cable Runs
• Path under floor between TV and
cable Cubby
• Cable run from 12 pax room
Power
Network
Table Cubby
Path for cable runs
65”
TV
8. 6th Floor Collaboration Space 2/3
– 8 Pax Room
Requirements
Power
• 2 Power sockets above TV
• 2 Power sockets under table
Network
• 1 Network port above TV
• 2 Network ports under table
Table Cubby
• 1 x Cutout hole in table for cubby.
Dimensions will be provided.
Cable Runs
• Path in ceiling between TV and side
wall.
• Path under floor from wall to Cubby.
Power
Network
Table Cubby
Path for cable runs
65”
TV
9. 7th Floor Meeting Room 1 –
14 Pax Room
Requirements
Power
• 6 Power sockets behind TV
• 4 Power sockets under table
Network
• 2 Network ports behind TV
• 4 Network ports under table
• 1 Network port in the ceiling for the
Room Scheduler device
Microphone
• 3 table mics, no action required
Ceiling Speakers
• Cutout hole in ceiling for speakers.
Dimensions will be provided.
Table Cubby
• 3 x Cutout hole in table for cubby’s.
Dimensions will be provided.
Cable Runs
• Path in the ceiling for cable run to
speakers
• Path under floor between TV and cable
Cubby
• Cable run along door frame for Room
scheduler device
Power
Network
Microphone
Ceiling speakers
Table Cubby
Path for cable runs
86”
TV
10. 7th Floor Meeting Room 2 –
6 Pax Room
Requirements
Power
• 4 Power sockets behind TV
• 2 Power sockets under table
Network
• 2 Network ports behind TV
• 2 Network ports under table
• 1 Network port in the ceiling for the
Room Scheduler device
Microphone
• 1 Table mic, no action required
Table Cubby
• 1 x Cutout hole in table for cubby.
Dimensions will be provided.
Cable Runs
• Path under floor between TV and
cable Cubby
• Cable run along door frame for
Room scheduler device
Power
Network
Microphone
Table Cubby
Path for cable runs
65”
TV
11. 7th Floor Meeting Room 3 –
6 Pax Room
Requirements
Power
• 4 Power sockets behind TV
• 2 Power sockets under table
Network
• 2 Network ports behind TV
• 2 Network ports under table
• 1 Network port in the ceiling for the
Room Scheduler device
Microphone
• 1 Table mic, no action required
Table Cubby
• Cutout hole in table for cubby.
Dimensions will be provided.
Cable Runs
• Path under floor between TV and
cable Cubby
• Cable run along door frame for
Room scheduler device
Power
Network
Microphone
Table Cubby
Path for cable runs
65”
TV
12. 7th Floor Collaboration Space 1/2
– 8 Pax Room
Requirements
Power
• 2 Power sockets above TV
• 2 Power sockets under table
Network
• 1 Network port above TV
• 2 Network ports under table
Table Cubby
• 1 x Cutout hole in table for cubby.
Dimensions will be provided.
Cable Runs
• Path in ceiling between TV and side
wall.
• Path under floor from wall to Cubby.
Power
Network
Table Cubby
Path for cable runs
65”
TV
13. 7th Floor Town
hall area
Requirements
Power
• 2 Power sockets behind main TV
• 2 Power sockets for additional
display
• 6 power sockets in small rack
Network
• 2 Network ports behind TV 1
• 2 Network ports behind TV 2
• 4 Network ports in small rack
Microphone
• Handheld and lapel mics, no
action required
Ceiling Speakers
• Cutout hole in ceiling for speakers.
Dimensions will be provided.
HDMI Wall plate
• Cutout hole in wall so we can
install a HDMI wall plate by the 2
TV’s
Cable Runs
• Path in the ceiling for cable runs to
speakers, cameras and TV’s from
small rack
• Small rack to be setup beside the
main TV.
Power
Network
PTZ Cameras
Ceiling speakers
Path for cable runs
HDMI Wall plate
Small rack
98”
TV
86”
TV
14. 6th/7th Floor Pods – 6
Pax Pod
Requirements
Power
• 2 Power sockets behind TV
Network
• 1 Network port behind TV
Power
Network
42”
TV