UNIT 5 Energy Coservation in Applications-81-97_compressed.pdf
1. Final Year B. Tech. (Electrical) : EM :
Unit 05: Energy Conservation in Applications (06 hrs)
8. Waste Heat Recovery Systems
2. Final Year B. Tech. (Electrical) : EM :
Unit 05: Energy Conservation in Applications (06 hrs)
8. Waste Heat Recovery Systems EC
Minimise Waste Heat Losses From Industrial Processes
Spent Gases Have Significant Thermal Energy
Furnaces, Boilers, Kilns, Ovens, And Dryers: Air And
Fuel Are Burned To Generate Heat
Part Of That Heat Is Transferred To Heating Device
Upgrade Waste Heat Recovery Technologies
3. Final Year B. Tech. (Electrical) : EM :
Unit 05: Energy Conservation in Applications (06 hrs)
8. Waste Heat Recovery Systems EC
Recovery Heat From
Flue Gas,
Engine Cooling Water,
Engine Exhaust,
Low Pressure Waste Steam,
Drying Oven Exhaust,
Boiler Blow down, Etc.
Recover Heat From Incinerator Off-gas
4. Final Year B. Tech. (Electrical) : EM :
Unit 05: Energy Conservation in Applications (06 hrs)
8. Waste Heat Recovery Systems EC
Use Of :
Waste Heat For Fuel Oil Heating, Boiler Feed-water
Heating, Outside Air Heating, Etc.
Chiller Waste Heat To Preheat Hot Water
Heat Pumps
Absorption Refrigeration
Thermal Wheels, Run-around Systems, Heat Pipe
Systems, Air-to-air Exchangers
5. Final Year B. Tech. (Electrical) : EM :
Unit 05: Energy Conservation in Applications (06 hrs)
9. Utility Industries ( T And D Sector)
India: T&D System : Three Level Structure:
1. State Grids
2. Regional Grids
3. Distribution
PS: Interconnected
T&D: India: Characterized By Heavy
Losses Of About 35%
Technical Losses And Commercial Losses
6. Final Year B. Tech. (Electrical) : EM :
Unit 05: Energy Conservation in Applications (06 hrs)
9. Utility Industries ( T And D Sector)
7. Final Year B. Tech. (Electrical) : EM :
Unit 05: Energy Conservation in Applications (06 hrs)
9. Utility Industries ( T And D Sector)
Technical Loss: Due To
Imperfection In Technical Aspect
Inadequate System Planning, Improper Voltage
Poor Power Factor Etc.
8. Final Year B. Tech. (Electrical) : EM :
Unit 05: Energy Conservation in Applications (06 hrs)
9. Utility Industries ( T And D Sector)
Commercial Losses: Directly Responsible For Wastage Of
Money Invested In T& D
Due To :
o Inefficient Management
o Improper Maintenance Etc.
o Corruption
o Metering Losses
o Human
9. Final Year B. Tech. (Electrical) : EM :
Unit 05: Energy Conservation in Applications (06 hrs)
9. Utility Industries ( T And D Sector)
EC:
Reduce Line Resistance- “ r ‟ Solid Conductors:
Replaced By Stranded Conductors (ACSR Or AAC) And By
Bundled Conductors In HT Line.
High Voltage Direct Current (HVDC) : To Transmit Large
Amount Of Power Over Long Distances
Transmitting Energy At HV
Optimum Sag
10. Final Year B. Tech. (Electrical) : EM :
Unit 05: Energy Conservation in Applications (06 hrs)
9. Utility Industries ( T And D Sector)
EC:
Voltage Level Can Be Controlled By Using Voltage
Controllers And By Using Voltage Stabilizer
React P Control (VAR)
Fault Control/ Reduction
Energy Management (DS)
FACTS
SCADA
11. Final Year B. Tech. (Electrical) : EM :
Unit 05: Energy Conservation in Applications (06 hrs)
9. Utility Industries ( T And D Sector)
EC:
12. Final Year B. Tech. (Electrical) : EM :
Unit 05: Energy Conservation in Applications (06 hrs)
10. Diesel Generators
13. Final Year B. Tech. (Electrical) : EM :
Unit 05: Energy Conservation in Applications (06 hrs)
10. Diesel Generators
DG (Distributed Generation) : Installation And Operation
Of Small Modular PGTs Combined With EMS
Used To Improve Operations Of Electricity Delivery
Systems At Or Near End User.
May Or May Not Be Connected To Grid
14. Final Year B. Tech. (Electrical) : EM :
Unit 05: Energy Conservation in Applications (06 hrs)
10. Diesel Generators
15. Final Year B. Tech. (Electrical) : EM :
Unit 05: Energy Conservation in Applications (06 hrs)
10. Diesel Generators
16. Final Year B. Tech. (Electrical) : EM :
Unit 05: Energy Conservation in Applications (06 hrs)
10. Diesel Generators EC
Steady Load Conditions
Cold, Dust Free Air At Intake ( Air Washers)
Improve Air Filtration.
Fuel Oil Storage, Handling And Preparation As Per
Manufacturers' Guidelines/Oil Company Data
Fuel Oil Additives In Case Benefit Fuel Oil Properties
Calibration: Fuel Injection Pumps Frequently
Compliance With Maintenance Checklist
Avoiding Fluctuations, Imbalance In Phases, Harmonic
Loads
17. Final Year B. Tech. (Electrical) : EM :
Unit 05: Energy Conservation in Applications (06 hrs)
10. Diesel Generators
Waste Heat Recovery System Adoption For Steam
Partial Use Of Biomass Gas For Generation.
Tar Removal From Gas For Engine In Long Run.
Consider Parallel Operation For Fuel Economy
Regular Field Trials To Monitor Performance, And
Maintenance Planning As Per Requirements
END OF UNIT 5