SlideShare a Scribd company logo
Etisalat&Ericsson
5Gcooperationandknowledgesharingsessions
5G
Ericsson Internal | 2018-02-21
5GFinaltopology,NSAoption3x
gNB BB6630 (midBand)
eNB BB5216 (800,2100)
DUS
DUW
DUG
Router 6471 +TDM1001
Intelligent Connectivity GPS GM Synch
NGS Sych
10G
E1
5G E/// EPC
+ UDC
• Add 5G in co-loc w/ 4G site in NSA with band 4G, FDD
• For FOA sites (B42), anchoring band will be B1 or B20
• Replace TCU/SIU with R6471 with Time/Phase Synch source (GPS GM, 1588v2) and 10Gbps ports
• Both scenarios are shown here; GPON and MW. Dark fiber to be considered for some sites as well
IP/MPLS
PE
ML
10G SFTP+
1G
TCU
1G
10G
WNC Pocket
Router
GPON
OLT
PE
NR AIR6488
B42
5G/4G NSA
Antenna
2G/3G/4G
eCPRI
2018-08-12 | Ericsson Internal | Page 7
IP/MPLS
DAS VRF
BSC
RNC
EPC
ENM
LTE2300
3G900
3G2100
LTE1800
5G
TDM1001
PE-AGG
2G DUG
GPON
R6471
1/10
1/1
1/2
1/3
1/4
1/5
1/9
R6471+TDM1001Connectivity
GPON/DarkFiberBH
RJ45
1G SFP
E1 Cable
10G SFP
2018-08-12 | Ericsson Internal | Page 10
5G New hardware
BaseBand 6630
AIR 6488
Router6471 + TDM1001
2018-08-12 | Ericsson Internal | Page 11
Advanced Antenna System (AAS)
—
64
— TX/64RX with 128 AE (B42 with 192 AE)
Up to
— 200W
EIRP
— upto 76 dBm
Up to
— 100 MHz IBW
Up to
— 3 carriers NR and/or LTE (band dependent)
Max total carrier BW is
— 100MHz for NR, or 60MHz for LTE
3
— x 10 Gbps eCPRI
Weight: ~
— 45 kg
Size (H x W x D): ~
— 810 x 400 x 200 mm (band depended)
— -48 VDC
— -40 to +55 ̊C
AIR 6488
2018-08-12 | Ericsson Internal | Page 8
LTE2300
3G2100
LTE1800
3G900
5G
GPON
DUG1_9
RJ45
1G SFP
E1 Cable
R6471+TDM1001Connectivity
GPON/DarkFiberBH
GPS
DUG2_9
DUG1_18
10G SFP
2018-08-12 | Ericsson Internal | Page 12
AIR6488B42
Technical Specification
Antenna Elements 128
Antenna Branches 64T64R
Antenna Matrix (row x col) 8 x 8, (2x1 subarray)
Band – B42D (FOA) 3500-3600Mhz
Band –B42F 3420-3600Mhz
IBW 100 MHz
Output Power 200 W
Power Consumption <1200 W
Weight ~45 Kg
Dimensions 800*400*150
Type of cooling Passive
CEPT compliance
Multi-layer MU MIMO: Up to 16 layers
NOTE: AIR B42D will be the 1st available in Q3/4, then B42F and B43 in late Q4
Technical Specification
Antenna Elements 128
Antenna Branches 64T64R
Antenna Matrix (row x col) 8 x 8, (2x1 subarray)
Band 3600-3800Mhz
IBW 100 MHz
Output Power 200 W
Power Consumption <1200 W
Weight ~45 Kg
Dimensions 800*400*150
Type of cooling Passive
CEPT compliance
Multi-layer MU MIMO: Up to 16 layers
AIR6488B43
BASEBAND 6630
AIR6488, BB6630, Router
Typical
(W)
Max (W)
Power
supply
Fuse Rating(A)
Total Power
Consumption (W)
3 x AIR6488 1200 -48V DC 3*40 (min 50max) 4200
1x Baseband 6630 120 180 -48V DC 1*30 180
Router 6471/2 35 60 -48V DC 1*6 60
Total/5G 3sectors 4440
2018-08-12 | Ericsson Internal | Page 13
The AIR unit is designed for outdoor use but to ensure optimal
operation, avoid the following:
• Hot microclimates caused by, for example, heat radiated or
reflected from dark or metallic walls or floors .
• Chimney mouths or ventilation system outlets
• Large glass or concrete surfaces .
Avoid radio interference by keeping the area directly in front of
the antenna clear of the following:
• Metal surfaces or objects such as railings, ladders, or chains .
• Equipment generating electromagnetic fields, for example,
electric motors in air conditioners or diesel generators .
• RBS equipment
AIR 6488 Outdoor Installation
Environments to Avoid
2018-08-12 | Ericsson Internal | Page 14
AIR Unit Fuse and Circuit Breaker Recommendations
AIR Unit Parts
Hardware & Power
2018-08-12 | Ericsson Internal | Page 15
AIR 6488 Unit Connection Interfaces
2018-08-12 | Ericsson Internal | Page 16
The AIR unit is equipped with optical indicators that show the system status.
AIR 6488 Optical Indicators
2018-08-12 | Ericsson Internal | Page 17
—Optimized for main-remote configurations
— 19 inch wide, 1U high, <352mm deep
— 15 SFP/SFP+ for CPRI inter-connect to Radio Units reducing the need for Baseband R503
— 2 optical 1/10Gbps SFP/SFP+ ports and 2 electrical 1Gbps RJ45 ports
— Eight External Alarm ports
— Dual 48V DC power feeding
— Self-contained environmental control & field replaceable fan unit
— Hardware Prepared for NR (5G) and eCPRI
Baseband 6630
2018-08-12 | Ericsson Internal | Page 18
comparison
› Baseband 6630/20 is standalone & has its own
climate control
› Baseband 6630/20 has 15 CPRI ports & dual
power feeding
› Typical power consumption estimated to
(at 25°C and typical load)
Baseband 6630: 123W
Baseband 6620: 93W
The RBS
› 6000 chassis is mandatory for Baseband
5216/12
Baseband R
› 503 needed to increase number of CPRI
ports
Baseband
› 6630 will have > 50W lower power
consumption compared to the corresponding
Baseband Main Unit (6601) + Baseband 5216 +
Baseband R503 configuration
Baseband Main Unit (6601) + Baseband 5216/5212 + dummy
OR
Baseband Main Unit (6601) + Baseband 5216/5212 + Baseband
R503
HWAC to enable more than 6 CPRI ports
Main
Unit
6601
Baseband
5212/16
Baseband
R503
6620/30
Baseband
2018-08-12 | Ericsson Internal | Page 19
—In controlled environments
—Mounting in 19 inch racks or in Transmission (TM) compartment in Ericsson enclosures
BB6630 Mounting
D
U
x
D
U
x
PDU
SCU
PCF
R
U
S
R
U
S
R
U
S
R
U
S
R
U
S
R
U
S
SHU
TCU 04
PDU
3.5U subrack
TM Space
Air restrictor plate incl CM
Cable management
2018-08-12 | Ericsson Internal | Page 20
BB6630 Front & rear view
2018-08-12 | Ericsson Internal | Page 21
BB6630 Front panel Interfaces
2018-08-12 | Ericsson Internal | Page 22
BB6630 Factory & power reset
— Use a pen to press down the Factory Reset Button for more than 8 seconds. Wait until the
unit has been restarted and the Operational optical indicator once again is flashing slowly at
0.5 Hz, before releasing the button
2018-08-12 | Ericsson Internal | Page 23
BB6630 installation
• The standard brackets are movable and can be placed in two different positions to adjust the baseband unit
in the right position in the hosting rack.
• When installing the baseband unit in an RBS, make sure to have the brackets in the 50 mm position.
• For cooling purposes the minimum free space is 30 mm behind the baseband unit.
2018-08-12 | Ericsson Internal | Page 24
GROUNDING
• Ground the baseband unit by connecting it to an grounding cable.
• If the unit is installed in an RBS or Enclosure, the grounding cable is not required.
2018-08-12 | Ericsson Internal | Page 25
Hardened and cost effective CSR for emerging market and
suburban sites.
— 30G Full Duplex Forwarding Capacity
— 2x1/10G SFP+, 4x1G SFP, 4x1G RJ-45
— 2 Gbps IPSec ⃰
— 128 L3VPN, 768 PW
— 8Gb packet buffer, 512 queues
— 1RU, 33W(TYP)
— 219 mm x 41mm x 220mm (250mm depth with optional fan)
— -40ºC to 65ºC
— Passive cooling with optional fan accessory for temp above 55C
— Advance sync features
— Programmability and SDN support
Router 6471
Indoor small site router
⃰ HW prepared for 8 Gbps
2018-08-12 | Ericsson Internal | Page 26
6471 interfaces & capacity
Dual power
feed
2x GE/10GE SFP+ ports
4x GE SFP ports
4x 100/1000 Base-T RJ45 ports
1x GE Base-T Ethernet for
out-of-band management
1x USB 2.0 port
1x RJ45 Alarm port for 3 input
and 1 output alarm contacts
1x RJ45 console
port
Synchronization interfaces:
1x RJ45 port 1PPS+TOD (ITU-T G.703)
2018-08-12 | Ericsson Internal | Page 27
— 8xE1/T1 Abis over IP
— 16 x T1/E1 CES
— 1 x GigE RJ-45/SFP combo port
— 1 x Ethernet management port
— 1RU, 20W(TYP)
— 219 mm x 41mm x 220mm
— -40ºC to 65ºC,
— Passive cooling
— Managed as Attached Unit of any indoor Router 6000 variants
(e.g. No seperate IP address)
— Can be installed in the same 1RU hosting shelf next to Router
6471
TDM 1001
E1 CES/ABIS expansion module
19”
1RU
Router 6471
TDM 1001
Hosting Shelf
2018-08-12 | Ericsson Internal | Page 28
TDM 1001 interfaces & capacity
1x GE SFP
1x 100/1000 Base-T RJ45 ports
1x GE Base-T Ethernet for
out-of-band management
Dual power feed
8x RJ45 ports for up to 16x E1/T1 interfaces
1x RJ45 console port
Ericsson.com

More Related Content

Similar to toaz.info-5g-solution-overview-pr_306866f43cebfb285586e3dd90989b89.pdf

baseband-6648.pdf
baseband-6648.pdfbaseband-6648.pdf
baseband-6648.pdf
mehdiberenji
 
cisco-air-cap3702p-q-k9-datasheet.pdf
cisco-air-cap3702p-q-k9-datasheet.pdfcisco-air-cap3702p-q-k9-datasheet.pdf
cisco-air-cap3702p-q-k9-datasheet.pdf
Hi-Network.com
 
Gigalight Solutions for 5G Optical Network
Gigalight Solutions for 5G Optical NetworkGigalight Solutions for 5G Optical Network
Gigalight Solutions for 5G Optical Network
Gigalight
 
Huaweiumtsnodebconfigurationprinciple 161222082051
Huaweiumtsnodebconfigurationprinciple 161222082051Huaweiumtsnodebconfigurationprinciple 161222082051
Huaweiumtsnodebconfigurationprinciple 161222082051
moussaCoulibaly22
 
Huawei umts node b configuration principle
Huawei umts node b configuration principleHuawei umts node b configuration principle
Huawei umts node b configuration principle
Yaser Al-Abdali
 
cisco-air-cap3702p-n-k9-datasheet.pdf
cisco-air-cap3702p-n-k9-datasheet.pdfcisco-air-cap3702p-n-k9-datasheet.pdf
cisco-air-cap3702p-n-k9-datasheet.pdf
Hi-Network.com
 
Mobilink 2G3G Swap Guide V1.8 20150406 (1)
Mobilink 2G3G Swap Guide V1.8 20150406 (1)Mobilink 2G3G Swap Guide V1.8 20150406 (1)
Mobilink 2G3G Swap Guide V1.8 20150406 (1)
Abdul Mateen Rahim
 
cisco-air-ap2802e-c-k9c-datasheet.pdf
cisco-air-ap2802e-c-k9c-datasheet.pdfcisco-air-ap2802e-c-k9c-datasheet.pdf
cisco-air-ap2802e-c-k9c-datasheet.pdf
Hi-Network.com
 
cisco-n2k-c2232pp-datasheet.pdf
cisco-n2k-c2232pp-datasheet.pdfcisco-n2k-c2232pp-datasheet.pdf
cisco-n2k-c2232pp-datasheet.pdf
Hi-Network.com
 
Fujitsu Iccad Presentation--Enable 100G
Fujitsu Iccad Presentation--Enable 100GFujitsu Iccad Presentation--Enable 100G
Fujitsu Iccad Presentation--Enable 100G
kennliu
 
cisco-air-ap3802p-a-k9-datasheet.pdf
cisco-air-ap3802p-a-k9-datasheet.pdfcisco-air-ap3802p-a-k9-datasheet.pdf
cisco-air-ap3802p-a-k9-datasheet.pdf
Hi-Network.com
 
cisco-air-ap2802e-g-k9c-datasheet.pdf
cisco-air-ap2802e-g-k9c-datasheet.pdfcisco-air-ap2802e-g-k9c-datasheet.pdf
cisco-air-ap2802e-g-k9c-datasheet.pdf
Hi-Network.com
 
cisco-air-cap3702p-r-k9-datasheet.pdf
cisco-air-cap3702p-r-k9-datasheet.pdfcisco-air-cap3702p-r-k9-datasheet.pdf
cisco-air-cap3702p-r-k9-datasheet.pdf
Hi-Network.com
 
Gpon Network
Gpon NetworkGpon Network
Gpon Network
mansoor_gr8
 
Gpon Network
Gpon NetworkGpon Network
Gpon Network
mansoor_gr8
 
IGS-6325-8T8S4X Industrial Managed Ethernet Switch
IGS-6325-8T8S4X  Industrial Managed Ethernet SwitchIGS-6325-8T8S4X  Industrial Managed Ethernet Switch
IGS-6325-8T8S4X Industrial Managed Ethernet Switch
BluBoxx Communication Pvt. ltd
 
cisco-air-ap2802e-z-k9-datasheet.pdf
cisco-air-ap2802e-z-k9-datasheet.pdfcisco-air-ap2802e-z-k9-datasheet.pdf
cisco-air-ap2802e-z-k9-datasheet.pdf
Hi-Network.com
 
Introduction to itu g.hn eo c 161110
Introduction to itu g.hn eo c 161110Introduction to itu g.hn eo c 161110
Introduction to itu g.hn eo c 161110
ljk1104
 
cisco-air-ap2802e-f-k9c-datasheet.pdf
cisco-air-ap2802e-f-k9c-datasheet.pdfcisco-air-ap2802e-f-k9c-datasheet.pdf
cisco-air-ap2802e-f-k9c-datasheet.pdf
Hi-Network.com
 
cisco-air-ap2802e-t-k9-datasheet.pdf
cisco-air-ap2802e-t-k9-datasheet.pdfcisco-air-ap2802e-t-k9-datasheet.pdf
cisco-air-ap2802e-t-k9-datasheet.pdf
Hi-Network.com
 

Similar to toaz.info-5g-solution-overview-pr_306866f43cebfb285586e3dd90989b89.pdf (20)

baseband-6648.pdf
baseband-6648.pdfbaseband-6648.pdf
baseband-6648.pdf
 
cisco-air-cap3702p-q-k9-datasheet.pdf
cisco-air-cap3702p-q-k9-datasheet.pdfcisco-air-cap3702p-q-k9-datasheet.pdf
cisco-air-cap3702p-q-k9-datasheet.pdf
 
Gigalight Solutions for 5G Optical Network
Gigalight Solutions for 5G Optical NetworkGigalight Solutions for 5G Optical Network
Gigalight Solutions for 5G Optical Network
 
Huaweiumtsnodebconfigurationprinciple 161222082051
Huaweiumtsnodebconfigurationprinciple 161222082051Huaweiumtsnodebconfigurationprinciple 161222082051
Huaweiumtsnodebconfigurationprinciple 161222082051
 
Huawei umts node b configuration principle
Huawei umts node b configuration principleHuawei umts node b configuration principle
Huawei umts node b configuration principle
 
cisco-air-cap3702p-n-k9-datasheet.pdf
cisco-air-cap3702p-n-k9-datasheet.pdfcisco-air-cap3702p-n-k9-datasheet.pdf
cisco-air-cap3702p-n-k9-datasheet.pdf
 
Mobilink 2G3G Swap Guide V1.8 20150406 (1)
Mobilink 2G3G Swap Guide V1.8 20150406 (1)Mobilink 2G3G Swap Guide V1.8 20150406 (1)
Mobilink 2G3G Swap Guide V1.8 20150406 (1)
 
cisco-air-ap2802e-c-k9c-datasheet.pdf
cisco-air-ap2802e-c-k9c-datasheet.pdfcisco-air-ap2802e-c-k9c-datasheet.pdf
cisco-air-ap2802e-c-k9c-datasheet.pdf
 
cisco-n2k-c2232pp-datasheet.pdf
cisco-n2k-c2232pp-datasheet.pdfcisco-n2k-c2232pp-datasheet.pdf
cisco-n2k-c2232pp-datasheet.pdf
 
Fujitsu Iccad Presentation--Enable 100G
Fujitsu Iccad Presentation--Enable 100GFujitsu Iccad Presentation--Enable 100G
Fujitsu Iccad Presentation--Enable 100G
 
cisco-air-ap3802p-a-k9-datasheet.pdf
cisco-air-ap3802p-a-k9-datasheet.pdfcisco-air-ap3802p-a-k9-datasheet.pdf
cisco-air-ap3802p-a-k9-datasheet.pdf
 
cisco-air-ap2802e-g-k9c-datasheet.pdf
cisco-air-ap2802e-g-k9c-datasheet.pdfcisco-air-ap2802e-g-k9c-datasheet.pdf
cisco-air-ap2802e-g-k9c-datasheet.pdf
 
cisco-air-cap3702p-r-k9-datasheet.pdf
cisco-air-cap3702p-r-k9-datasheet.pdfcisco-air-cap3702p-r-k9-datasheet.pdf
cisco-air-cap3702p-r-k9-datasheet.pdf
 
Gpon Network
Gpon NetworkGpon Network
Gpon Network
 
Gpon Network
Gpon NetworkGpon Network
Gpon Network
 
IGS-6325-8T8S4X Industrial Managed Ethernet Switch
IGS-6325-8T8S4X  Industrial Managed Ethernet SwitchIGS-6325-8T8S4X  Industrial Managed Ethernet Switch
IGS-6325-8T8S4X Industrial Managed Ethernet Switch
 
cisco-air-ap2802e-z-k9-datasheet.pdf
cisco-air-ap2802e-z-k9-datasheet.pdfcisco-air-ap2802e-z-k9-datasheet.pdf
cisco-air-ap2802e-z-k9-datasheet.pdf
 
Introduction to itu g.hn eo c 161110
Introduction to itu g.hn eo c 161110Introduction to itu g.hn eo c 161110
Introduction to itu g.hn eo c 161110
 
cisco-air-ap2802e-f-k9c-datasheet.pdf
cisco-air-ap2802e-f-k9c-datasheet.pdfcisco-air-ap2802e-f-k9c-datasheet.pdf
cisco-air-ap2802e-f-k9c-datasheet.pdf
 
cisco-air-ap2802e-t-k9-datasheet.pdf
cisco-air-ap2802e-t-k9-datasheet.pdfcisco-air-ap2802e-t-k9-datasheet.pdf
cisco-air-ap2802e-t-k9-datasheet.pdf
 

More from wafawafa52

Evo Controller 8200BSC PRESENTATION .
Evo Controller 8200BSC PRESENTATION     .Evo Controller 8200BSC PRESENTATION     .
Evo Controller 8200BSC PRESENTATION .
wafawafa52
 
Master Baseband 6620 & 6630 Commissioning On Site
Master Baseband 6620 & 6630 Commissioning On SiteMaster Baseband 6620 & 6630 Commissioning On Site
Master Baseband 6620 & 6630 Commissioning On Site
wafawafa52
 
Ericsson LTE Throughput Troubleshooting Techniques.ppt
Ericsson LTE Throughput Troubleshooting Techniques.pptEricsson LTE Throughput Troubleshooting Techniques.ppt
Ericsson LTE Throughput Troubleshooting Techniques.ppt
wafawafa52
 
Model test result .pptx
Model test result                  .pptxModel test result                  .pptx
Model test result .pptx
wafawafa52
 
Recovery-XPIC-Ericsson- 2-0-MMU 4 A.pptx
Recovery-XPIC-Ericsson- 2-0-MMU 4 A.pptxRecovery-XPIC-Ericsson- 2-0-MMU 4 A.pptx
Recovery-XPIC-Ericsson- 2-0-MMU 4 A.pptx
wafawafa52
 
515878259-Node-Group-Synch-Workshop.pptx
515878259-Node-Group-Synch-Workshop.pptx515878259-Node-Group-Synch-Workshop.pptx
515878259-Node-Group-Synch-Workshop.pptx
wafawafa52
 
385288768-TD-Training-Modules-Mobilis.pptx
385288768-TD-Training-Modules-Mobilis.pptx385288768-TD-Training-Modules-Mobilis.pptx
385288768-TD-Training-Modules-Mobilis.pptx
wafawafa52
 
Ericsson Microwave Products Overview.ppt
Ericsson Microwave Products Overview.pptEricsson Microwave Products Overview.ppt
Ericsson Microwave Products Overview.ppt
wafawafa52
 
BaseBand-6630-Moshell-Commands .pdf
BaseBand-6630-Moshell-Commands      .pdfBaseBand-6630-Moshell-Commands      .pdf
BaseBand-6630-Moshell-Commands .pdf
wafawafa52
 
5-LTE-IP-Troubleshooting .ppt
5-LTE-IP-Troubleshooting            .ppt5-LTE-IP-Troubleshooting            .ppt
5-LTE-IP-Troubleshooting .ppt
wafawafa52
 
Sharing-Knowledge-OAM-3G-Ericsson .ppt
Sharing-Knowledge-OAM-3G-Ericsson   .pptSharing-Knowledge-OAM-3G-Ericsson   .ppt
Sharing-Knowledge-OAM-3G-Ericsson .ppt
wafawafa52
 
LTE-BASICS-ppt .ppt
LTE-BASICS-ppt                      .pptLTE-BASICS-ppt                      .ppt
LTE-BASICS-ppt .ppt
wafawafa52
 
ran-introicbasictroubleshooting3-230122164831-426c58cd.pdf
ran-introicbasictroubleshooting3-230122164831-426c58cd.pdfran-introicbasictroubleshooting3-230122164831-426c58cd.pdf
ran-introicbasictroubleshooting3-230122164831-426c58cd.pdf
wafawafa52
 
mop-baseband-integration-xl-project-pa-1docxdocx-pr_299cefaa0fd3e32dd950c7218...
mop-baseband-integration-xl-project-pa-1docxdocx-pr_299cefaa0fd3e32dd950c7218...mop-baseband-integration-xl-project-pa-1docxdocx-pr_299cefaa0fd3e32dd950c7218...
mop-baseband-integration-xl-project-pa-1docxdocx-pr_299cefaa0fd3e32dd950c7218...
wafawafa52
 
FPGA_Logic.pdf
FPGA_Logic.pdfFPGA_Logic.pdf
FPGA_Logic.pdf
wafawafa52
 
DWDM-Presentation.pdf
DWDM-Presentation.pdfDWDM-Presentation.pdf
DWDM-Presentation.pdf
wafawafa52
 
Verilog HDL Design Examples ( PDFDrive ).pdf
Verilog HDL Design Examples ( PDFDrive ).pdfVerilog HDL Design Examples ( PDFDrive ).pdf
Verilog HDL Design Examples ( PDFDrive ).pdf
wafawafa52
 
VHDL summary.pdf
VHDL summary.pdfVHDL summary.pdf
VHDL summary.pdf
wafawafa52
 
ROM PAL PLA.ppt
ROM PAL PLA.pptROM PAL PLA.ppt
ROM PAL PLA.ppt
wafawafa52
 
Lecture 16 RC Architecture Types & FPGA Interns Lecturer.pptx
Lecture 16 RC Architecture Types & FPGA Interns Lecturer.pptxLecture 16 RC Architecture Types & FPGA Interns Lecturer.pptx
Lecture 16 RC Architecture Types & FPGA Interns Lecturer.pptx
wafawafa52
 

More from wafawafa52 (20)

Evo Controller 8200BSC PRESENTATION .
Evo Controller 8200BSC PRESENTATION     .Evo Controller 8200BSC PRESENTATION     .
Evo Controller 8200BSC PRESENTATION .
 
Master Baseband 6620 & 6630 Commissioning On Site
Master Baseband 6620 & 6630 Commissioning On SiteMaster Baseband 6620 & 6630 Commissioning On Site
Master Baseband 6620 & 6630 Commissioning On Site
 
Ericsson LTE Throughput Troubleshooting Techniques.ppt
Ericsson LTE Throughput Troubleshooting Techniques.pptEricsson LTE Throughput Troubleshooting Techniques.ppt
Ericsson LTE Throughput Troubleshooting Techniques.ppt
 
Model test result .pptx
Model test result                  .pptxModel test result                  .pptx
Model test result .pptx
 
Recovery-XPIC-Ericsson- 2-0-MMU 4 A.pptx
Recovery-XPIC-Ericsson- 2-0-MMU 4 A.pptxRecovery-XPIC-Ericsson- 2-0-MMU 4 A.pptx
Recovery-XPIC-Ericsson- 2-0-MMU 4 A.pptx
 
515878259-Node-Group-Synch-Workshop.pptx
515878259-Node-Group-Synch-Workshop.pptx515878259-Node-Group-Synch-Workshop.pptx
515878259-Node-Group-Synch-Workshop.pptx
 
385288768-TD-Training-Modules-Mobilis.pptx
385288768-TD-Training-Modules-Mobilis.pptx385288768-TD-Training-Modules-Mobilis.pptx
385288768-TD-Training-Modules-Mobilis.pptx
 
Ericsson Microwave Products Overview.ppt
Ericsson Microwave Products Overview.pptEricsson Microwave Products Overview.ppt
Ericsson Microwave Products Overview.ppt
 
BaseBand-6630-Moshell-Commands .pdf
BaseBand-6630-Moshell-Commands      .pdfBaseBand-6630-Moshell-Commands      .pdf
BaseBand-6630-Moshell-Commands .pdf
 
5-LTE-IP-Troubleshooting .ppt
5-LTE-IP-Troubleshooting            .ppt5-LTE-IP-Troubleshooting            .ppt
5-LTE-IP-Troubleshooting .ppt
 
Sharing-Knowledge-OAM-3G-Ericsson .ppt
Sharing-Knowledge-OAM-3G-Ericsson   .pptSharing-Knowledge-OAM-3G-Ericsson   .ppt
Sharing-Knowledge-OAM-3G-Ericsson .ppt
 
LTE-BASICS-ppt .ppt
LTE-BASICS-ppt                      .pptLTE-BASICS-ppt                      .ppt
LTE-BASICS-ppt .ppt
 
ran-introicbasictroubleshooting3-230122164831-426c58cd.pdf
ran-introicbasictroubleshooting3-230122164831-426c58cd.pdfran-introicbasictroubleshooting3-230122164831-426c58cd.pdf
ran-introicbasictroubleshooting3-230122164831-426c58cd.pdf
 
mop-baseband-integration-xl-project-pa-1docxdocx-pr_299cefaa0fd3e32dd950c7218...
mop-baseband-integration-xl-project-pa-1docxdocx-pr_299cefaa0fd3e32dd950c7218...mop-baseband-integration-xl-project-pa-1docxdocx-pr_299cefaa0fd3e32dd950c7218...
mop-baseband-integration-xl-project-pa-1docxdocx-pr_299cefaa0fd3e32dd950c7218...
 
FPGA_Logic.pdf
FPGA_Logic.pdfFPGA_Logic.pdf
FPGA_Logic.pdf
 
DWDM-Presentation.pdf
DWDM-Presentation.pdfDWDM-Presentation.pdf
DWDM-Presentation.pdf
 
Verilog HDL Design Examples ( PDFDrive ).pdf
Verilog HDL Design Examples ( PDFDrive ).pdfVerilog HDL Design Examples ( PDFDrive ).pdf
Verilog HDL Design Examples ( PDFDrive ).pdf
 
VHDL summary.pdf
VHDL summary.pdfVHDL summary.pdf
VHDL summary.pdf
 
ROM PAL PLA.ppt
ROM PAL PLA.pptROM PAL PLA.ppt
ROM PAL PLA.ppt
 
Lecture 16 RC Architecture Types & FPGA Interns Lecturer.pptx
Lecture 16 RC Architecture Types & FPGA Interns Lecturer.pptxLecture 16 RC Architecture Types & FPGA Interns Lecturer.pptx
Lecture 16 RC Architecture Types & FPGA Interns Lecturer.pptx
 

Recently uploaded

NATURAL DEEP EUTECTIC SOLVENTS AS ANTI-FREEZING AGENT
NATURAL DEEP EUTECTIC SOLVENTS AS ANTI-FREEZING AGENTNATURAL DEEP EUTECTIC SOLVENTS AS ANTI-FREEZING AGENT
NATURAL DEEP EUTECTIC SOLVENTS AS ANTI-FREEZING AGENT
Addu25809
 
CompEx~Manual~1210 (2).pdf COMPEX GAS AND VAPOURS
CompEx~Manual~1210 (2).pdf COMPEX GAS AND VAPOURSCompEx~Manual~1210 (2).pdf COMPEX GAS AND VAPOURS
CompEx~Manual~1210 (2).pdf COMPEX GAS AND VAPOURS
RamonNovais6
 
Digital Twins Computer Networking Paper Presentation.pptx
Digital Twins Computer Networking Paper Presentation.pptxDigital Twins Computer Networking Paper Presentation.pptx
Digital Twins Computer Networking Paper Presentation.pptx
aryanpankaj78
 
Applications of artificial Intelligence in Mechanical Engineering.pdf
Applications of artificial Intelligence in Mechanical Engineering.pdfApplications of artificial Intelligence in Mechanical Engineering.pdf
Applications of artificial Intelligence in Mechanical Engineering.pdf
Atif Razi
 
1FIDIC-CONSTRUCTION-CONTRACT-2ND-ED-2017-RED-BOOK.pdf
1FIDIC-CONSTRUCTION-CONTRACT-2ND-ED-2017-RED-BOOK.pdf1FIDIC-CONSTRUCTION-CONTRACT-2ND-ED-2017-RED-BOOK.pdf
1FIDIC-CONSTRUCTION-CONTRACT-2ND-ED-2017-RED-BOOK.pdf
MadhavJungKarki
 
Bayesian Decision Theory details ML.pptx
Bayesian Decision Theory details ML.pptxBayesian Decision Theory details ML.pptx
Bayesian Decision Theory details ML.pptx
amrita chaturvedi
 
Null Bangalore | Pentesters Approach to AWS IAM
Null Bangalore | Pentesters Approach to AWS IAMNull Bangalore | Pentesters Approach to AWS IAM
Null Bangalore | Pentesters Approach to AWS IAM
Divyanshu
 
VARIABLE FREQUENCY DRIVE. VFDs are widely used in industrial applications for...
VARIABLE FREQUENCY DRIVE. VFDs are widely used in industrial applications for...VARIABLE FREQUENCY DRIVE. VFDs are widely used in industrial applications for...
VARIABLE FREQUENCY DRIVE. VFDs are widely used in industrial applications for...
PIMR BHOPAL
 
Generative AI Use cases applications solutions and implementation.pdf
Generative AI Use cases applications solutions and implementation.pdfGenerative AI Use cases applications solutions and implementation.pdf
Generative AI Use cases applications solutions and implementation.pdf
mahaffeycheryld
 
Mechanical Engineering on AAI Summer Training Report-003.pdf
Mechanical Engineering on AAI Summer Training Report-003.pdfMechanical Engineering on AAI Summer Training Report-003.pdf
Mechanical Engineering on AAI Summer Training Report-003.pdf
21UME003TUSHARDEB
 
CEC 352 - SATELLITE COMMUNICATION UNIT 1
CEC 352 - SATELLITE COMMUNICATION UNIT 1CEC 352 - SATELLITE COMMUNICATION UNIT 1
CEC 352 - SATELLITE COMMUNICATION UNIT 1
PKavitha10
 
5g-5G SA reg. -standalone-access-registration.pdf
5g-5G SA reg. -standalone-access-registration.pdf5g-5G SA reg. -standalone-access-registration.pdf
5g-5G SA reg. -standalone-access-registration.pdf
devtomar25
 
LLM Fine Tuning with QLoRA Cassandra Lunch 4, presented by Anant
LLM Fine Tuning with QLoRA Cassandra Lunch 4, presented by AnantLLM Fine Tuning with QLoRA Cassandra Lunch 4, presented by Anant
LLM Fine Tuning with QLoRA Cassandra Lunch 4, presented by Anant
Anant Corporation
 
Design and optimization of ion propulsion drone
Design and optimization of ion propulsion droneDesign and optimization of ion propulsion drone
Design and optimization of ion propulsion drone
bjmsejournal
 
Call For Paper -3rd International Conference on Artificial Intelligence Advan...
Call For Paper -3rd International Conference on Artificial Intelligence Advan...Call For Paper -3rd International Conference on Artificial Intelligence Advan...
Call For Paper -3rd International Conference on Artificial Intelligence Advan...
ijseajournal
 
DEEP LEARNING FOR SMART GRID INTRUSION DETECTION: A HYBRID CNN-LSTM-BASED MODEL
DEEP LEARNING FOR SMART GRID INTRUSION DETECTION: A HYBRID CNN-LSTM-BASED MODELDEEP LEARNING FOR SMART GRID INTRUSION DETECTION: A HYBRID CNN-LSTM-BASED MODEL
DEEP LEARNING FOR SMART GRID INTRUSION DETECTION: A HYBRID CNN-LSTM-BASED MODEL
ijaia
 
5G Radio Network Througput Problem Analysis HCIA.pdf
5G Radio Network Througput Problem Analysis HCIA.pdf5G Radio Network Througput Problem Analysis HCIA.pdf
5G Radio Network Througput Problem Analysis HCIA.pdf
AlvianRamadhani5
 
Software Engineering and Project Management - Introduction, Modeling Concepts...
Software Engineering and Project Management - Introduction, Modeling Concepts...Software Engineering and Project Management - Introduction, Modeling Concepts...
Software Engineering and Project Management - Introduction, Modeling Concepts...
Prakhyath Rai
 
An Introduction to the Compiler Designss
An Introduction to the Compiler DesignssAn Introduction to the Compiler Designss
An Introduction to the Compiler Designss
ElakkiaU
 
Supermarket Management System Project Report.pdf
Supermarket Management System Project Report.pdfSupermarket Management System Project Report.pdf
Supermarket Management System Project Report.pdf
Kamal Acharya
 

Recently uploaded (20)

NATURAL DEEP EUTECTIC SOLVENTS AS ANTI-FREEZING AGENT
NATURAL DEEP EUTECTIC SOLVENTS AS ANTI-FREEZING AGENTNATURAL DEEP EUTECTIC SOLVENTS AS ANTI-FREEZING AGENT
NATURAL DEEP EUTECTIC SOLVENTS AS ANTI-FREEZING AGENT
 
CompEx~Manual~1210 (2).pdf COMPEX GAS AND VAPOURS
CompEx~Manual~1210 (2).pdf COMPEX GAS AND VAPOURSCompEx~Manual~1210 (2).pdf COMPEX GAS AND VAPOURS
CompEx~Manual~1210 (2).pdf COMPEX GAS AND VAPOURS
 
Digital Twins Computer Networking Paper Presentation.pptx
Digital Twins Computer Networking Paper Presentation.pptxDigital Twins Computer Networking Paper Presentation.pptx
Digital Twins Computer Networking Paper Presentation.pptx
 
Applications of artificial Intelligence in Mechanical Engineering.pdf
Applications of artificial Intelligence in Mechanical Engineering.pdfApplications of artificial Intelligence in Mechanical Engineering.pdf
Applications of artificial Intelligence in Mechanical Engineering.pdf
 
1FIDIC-CONSTRUCTION-CONTRACT-2ND-ED-2017-RED-BOOK.pdf
1FIDIC-CONSTRUCTION-CONTRACT-2ND-ED-2017-RED-BOOK.pdf1FIDIC-CONSTRUCTION-CONTRACT-2ND-ED-2017-RED-BOOK.pdf
1FIDIC-CONSTRUCTION-CONTRACT-2ND-ED-2017-RED-BOOK.pdf
 
Bayesian Decision Theory details ML.pptx
Bayesian Decision Theory details ML.pptxBayesian Decision Theory details ML.pptx
Bayesian Decision Theory details ML.pptx
 
Null Bangalore | Pentesters Approach to AWS IAM
Null Bangalore | Pentesters Approach to AWS IAMNull Bangalore | Pentesters Approach to AWS IAM
Null Bangalore | Pentesters Approach to AWS IAM
 
VARIABLE FREQUENCY DRIVE. VFDs are widely used in industrial applications for...
VARIABLE FREQUENCY DRIVE. VFDs are widely used in industrial applications for...VARIABLE FREQUENCY DRIVE. VFDs are widely used in industrial applications for...
VARIABLE FREQUENCY DRIVE. VFDs are widely used in industrial applications for...
 
Generative AI Use cases applications solutions and implementation.pdf
Generative AI Use cases applications solutions and implementation.pdfGenerative AI Use cases applications solutions and implementation.pdf
Generative AI Use cases applications solutions and implementation.pdf
 
Mechanical Engineering on AAI Summer Training Report-003.pdf
Mechanical Engineering on AAI Summer Training Report-003.pdfMechanical Engineering on AAI Summer Training Report-003.pdf
Mechanical Engineering on AAI Summer Training Report-003.pdf
 
CEC 352 - SATELLITE COMMUNICATION UNIT 1
CEC 352 - SATELLITE COMMUNICATION UNIT 1CEC 352 - SATELLITE COMMUNICATION UNIT 1
CEC 352 - SATELLITE COMMUNICATION UNIT 1
 
5g-5G SA reg. -standalone-access-registration.pdf
5g-5G SA reg. -standalone-access-registration.pdf5g-5G SA reg. -standalone-access-registration.pdf
5g-5G SA reg. -standalone-access-registration.pdf
 
LLM Fine Tuning with QLoRA Cassandra Lunch 4, presented by Anant
LLM Fine Tuning with QLoRA Cassandra Lunch 4, presented by AnantLLM Fine Tuning with QLoRA Cassandra Lunch 4, presented by Anant
LLM Fine Tuning with QLoRA Cassandra Lunch 4, presented by Anant
 
Design and optimization of ion propulsion drone
Design and optimization of ion propulsion droneDesign and optimization of ion propulsion drone
Design and optimization of ion propulsion drone
 
Call For Paper -3rd International Conference on Artificial Intelligence Advan...
Call For Paper -3rd International Conference on Artificial Intelligence Advan...Call For Paper -3rd International Conference on Artificial Intelligence Advan...
Call For Paper -3rd International Conference on Artificial Intelligence Advan...
 
DEEP LEARNING FOR SMART GRID INTRUSION DETECTION: A HYBRID CNN-LSTM-BASED MODEL
DEEP LEARNING FOR SMART GRID INTRUSION DETECTION: A HYBRID CNN-LSTM-BASED MODELDEEP LEARNING FOR SMART GRID INTRUSION DETECTION: A HYBRID CNN-LSTM-BASED MODEL
DEEP LEARNING FOR SMART GRID INTRUSION DETECTION: A HYBRID CNN-LSTM-BASED MODEL
 
5G Radio Network Througput Problem Analysis HCIA.pdf
5G Radio Network Througput Problem Analysis HCIA.pdf5G Radio Network Througput Problem Analysis HCIA.pdf
5G Radio Network Througput Problem Analysis HCIA.pdf
 
Software Engineering and Project Management - Introduction, Modeling Concepts...
Software Engineering and Project Management - Introduction, Modeling Concepts...Software Engineering and Project Management - Introduction, Modeling Concepts...
Software Engineering and Project Management - Introduction, Modeling Concepts...
 
An Introduction to the Compiler Designss
An Introduction to the Compiler DesignssAn Introduction to the Compiler Designss
An Introduction to the Compiler Designss
 
Supermarket Management System Project Report.pdf
Supermarket Management System Project Report.pdfSupermarket Management System Project Report.pdf
Supermarket Management System Project Report.pdf
 

toaz.info-5g-solution-overview-pr_306866f43cebfb285586e3dd90989b89.pdf

  • 2. Ericsson Internal | 2018-02-21 5GFinaltopology,NSAoption3x gNB BB6630 (midBand) eNB BB5216 (800,2100) DUS DUW DUG Router 6471 +TDM1001 Intelligent Connectivity GPS GM Synch NGS Sych 10G E1 5G E/// EPC + UDC • Add 5G in co-loc w/ 4G site in NSA with band 4G, FDD • For FOA sites (B42), anchoring band will be B1 or B20 • Replace TCU/SIU with R6471 with Time/Phase Synch source (GPS GM, 1588v2) and 10Gbps ports • Both scenarios are shown here; GPON and MW. Dark fiber to be considered for some sites as well IP/MPLS PE ML 10G SFTP+ 1G TCU 1G 10G WNC Pocket Router GPON OLT PE NR AIR6488 B42 5G/4G NSA Antenna 2G/3G/4G eCPRI
  • 3. 2018-08-12 | Ericsson Internal | Page 7 IP/MPLS DAS VRF BSC RNC EPC ENM LTE2300 3G900 3G2100 LTE1800 5G TDM1001 PE-AGG 2G DUG GPON R6471 1/10 1/1 1/2 1/3 1/4 1/5 1/9 R6471+TDM1001Connectivity GPON/DarkFiberBH RJ45 1G SFP E1 Cable 10G SFP
  • 4. 2018-08-12 | Ericsson Internal | Page 10 5G New hardware BaseBand 6630 AIR 6488 Router6471 + TDM1001
  • 5. 2018-08-12 | Ericsson Internal | Page 11 Advanced Antenna System (AAS) — 64 — TX/64RX with 128 AE (B42 with 192 AE) Up to — 200W EIRP — upto 76 dBm Up to — 100 MHz IBW Up to — 3 carriers NR and/or LTE (band dependent) Max total carrier BW is — 100MHz for NR, or 60MHz for LTE 3 — x 10 Gbps eCPRI Weight: ~ — 45 kg Size (H x W x D): ~ — 810 x 400 x 200 mm (band depended) — -48 VDC — -40 to +55 ̊C AIR 6488
  • 6. 2018-08-12 | Ericsson Internal | Page 8 LTE2300 3G2100 LTE1800 3G900 5G GPON DUG1_9 RJ45 1G SFP E1 Cable R6471+TDM1001Connectivity GPON/DarkFiberBH GPS DUG2_9 DUG1_18 10G SFP
  • 7. 2018-08-12 | Ericsson Internal | Page 12 AIR6488B42 Technical Specification Antenna Elements 128 Antenna Branches 64T64R Antenna Matrix (row x col) 8 x 8, (2x1 subarray) Band – B42D (FOA) 3500-3600Mhz Band –B42F 3420-3600Mhz IBW 100 MHz Output Power 200 W Power Consumption <1200 W Weight ~45 Kg Dimensions 800*400*150 Type of cooling Passive CEPT compliance Multi-layer MU MIMO: Up to 16 layers NOTE: AIR B42D will be the 1st available in Q3/4, then B42F and B43 in late Q4 Technical Specification Antenna Elements 128 Antenna Branches 64T64R Antenna Matrix (row x col) 8 x 8, (2x1 subarray) Band 3600-3800Mhz IBW 100 MHz Output Power 200 W Power Consumption <1200 W Weight ~45 Kg Dimensions 800*400*150 Type of cooling Passive CEPT compliance Multi-layer MU MIMO: Up to 16 layers AIR6488B43 BASEBAND 6630 AIR6488, BB6630, Router Typical (W) Max (W) Power supply Fuse Rating(A) Total Power Consumption (W) 3 x AIR6488 1200 -48V DC 3*40 (min 50max) 4200 1x Baseband 6630 120 180 -48V DC 1*30 180 Router 6471/2 35 60 -48V DC 1*6 60 Total/5G 3sectors 4440
  • 8. 2018-08-12 | Ericsson Internal | Page 13 The AIR unit is designed for outdoor use but to ensure optimal operation, avoid the following: • Hot microclimates caused by, for example, heat radiated or reflected from dark or metallic walls or floors . • Chimney mouths or ventilation system outlets • Large glass or concrete surfaces . Avoid radio interference by keeping the area directly in front of the antenna clear of the following: • Metal surfaces or objects such as railings, ladders, or chains . • Equipment generating electromagnetic fields, for example, electric motors in air conditioners or diesel generators . • RBS equipment AIR 6488 Outdoor Installation Environments to Avoid
  • 9. 2018-08-12 | Ericsson Internal | Page 14 AIR Unit Fuse and Circuit Breaker Recommendations AIR Unit Parts Hardware & Power
  • 10. 2018-08-12 | Ericsson Internal | Page 15 AIR 6488 Unit Connection Interfaces
  • 11. 2018-08-12 | Ericsson Internal | Page 16 The AIR unit is equipped with optical indicators that show the system status. AIR 6488 Optical Indicators
  • 12. 2018-08-12 | Ericsson Internal | Page 17 —Optimized for main-remote configurations — 19 inch wide, 1U high, <352mm deep — 15 SFP/SFP+ for CPRI inter-connect to Radio Units reducing the need for Baseband R503 — 2 optical 1/10Gbps SFP/SFP+ ports and 2 electrical 1Gbps RJ45 ports — Eight External Alarm ports — Dual 48V DC power feeding — Self-contained environmental control & field replaceable fan unit — Hardware Prepared for NR (5G) and eCPRI Baseband 6630
  • 13. 2018-08-12 | Ericsson Internal | Page 18 comparison › Baseband 6630/20 is standalone & has its own climate control › Baseband 6630/20 has 15 CPRI ports & dual power feeding › Typical power consumption estimated to (at 25°C and typical load) Baseband 6630: 123W Baseband 6620: 93W The RBS › 6000 chassis is mandatory for Baseband 5216/12 Baseband R › 503 needed to increase number of CPRI ports Baseband › 6630 will have > 50W lower power consumption compared to the corresponding Baseband Main Unit (6601) + Baseband 5216 + Baseband R503 configuration Baseband Main Unit (6601) + Baseband 5216/5212 + dummy OR Baseband Main Unit (6601) + Baseband 5216/5212 + Baseband R503 HWAC to enable more than 6 CPRI ports Main Unit 6601 Baseband 5212/16 Baseband R503 6620/30 Baseband
  • 14. 2018-08-12 | Ericsson Internal | Page 19 —In controlled environments —Mounting in 19 inch racks or in Transmission (TM) compartment in Ericsson enclosures BB6630 Mounting D U x D U x PDU SCU PCF R U S R U S R U S R U S R U S R U S SHU TCU 04 PDU 3.5U subrack TM Space Air restrictor plate incl CM Cable management
  • 15. 2018-08-12 | Ericsson Internal | Page 20 BB6630 Front & rear view
  • 16. 2018-08-12 | Ericsson Internal | Page 21 BB6630 Front panel Interfaces
  • 17. 2018-08-12 | Ericsson Internal | Page 22 BB6630 Factory & power reset — Use a pen to press down the Factory Reset Button for more than 8 seconds. Wait until the unit has been restarted and the Operational optical indicator once again is flashing slowly at 0.5 Hz, before releasing the button
  • 18. 2018-08-12 | Ericsson Internal | Page 23 BB6630 installation • The standard brackets are movable and can be placed in two different positions to adjust the baseband unit in the right position in the hosting rack. • When installing the baseband unit in an RBS, make sure to have the brackets in the 50 mm position. • For cooling purposes the minimum free space is 30 mm behind the baseband unit.
  • 19. 2018-08-12 | Ericsson Internal | Page 24 GROUNDING • Ground the baseband unit by connecting it to an grounding cable. • If the unit is installed in an RBS or Enclosure, the grounding cable is not required.
  • 20. 2018-08-12 | Ericsson Internal | Page 25 Hardened and cost effective CSR for emerging market and suburban sites. — 30G Full Duplex Forwarding Capacity — 2x1/10G SFP+, 4x1G SFP, 4x1G RJ-45 — 2 Gbps IPSec ⃰ — 128 L3VPN, 768 PW — 8Gb packet buffer, 512 queues — 1RU, 33W(TYP) — 219 mm x 41mm x 220mm (250mm depth with optional fan) — -40ºC to 65ºC — Passive cooling with optional fan accessory for temp above 55C — Advance sync features — Programmability and SDN support Router 6471 Indoor small site router ⃰ HW prepared for 8 Gbps
  • 21. 2018-08-12 | Ericsson Internal | Page 26 6471 interfaces & capacity Dual power feed 2x GE/10GE SFP+ ports 4x GE SFP ports 4x 100/1000 Base-T RJ45 ports 1x GE Base-T Ethernet for out-of-band management 1x USB 2.0 port 1x RJ45 Alarm port for 3 input and 1 output alarm contacts 1x RJ45 console port Synchronization interfaces: 1x RJ45 port 1PPS+TOD (ITU-T G.703)
  • 22. 2018-08-12 | Ericsson Internal | Page 27 — 8xE1/T1 Abis over IP — 16 x T1/E1 CES — 1 x GigE RJ-45/SFP combo port — 1 x Ethernet management port — 1RU, 20W(TYP) — 219 mm x 41mm x 220mm — -40ºC to 65ºC, — Passive cooling — Managed as Attached Unit of any indoor Router 6000 variants (e.g. No seperate IP address) — Can be installed in the same 1RU hosting shelf next to Router 6471 TDM 1001 E1 CES/ABIS expansion module 19” 1RU Router 6471 TDM 1001 Hosting Shelf
  • 23. 2018-08-12 | Ericsson Internal | Page 28 TDM 1001 interfaces & capacity 1x GE SFP 1x 100/1000 Base-T RJ45 ports 1x GE Base-T Ethernet for out-of-band management Dual power feed 8x RJ45 ports for up to 16x E1/T1 interfaces 1x RJ45 console port