Done by:
Dr sarah abd alsalam
Supervised by:
Dr Ban
Rotary nickel titanium were first introduced
clinically in 1993 in represent a real shift in
endodintic
New design have been introduced over the years
attempting to make these instrument more
efficient, more flexible and safer in the term of
file seperation
Current rotary file systems are effective tools.
Nevertheless they have two main
shortcoming:-
A- They are unable to effectively clean and
shape the oval canals and depend too much on
irrigant to do cleaning
B- The long term survival of the tooth is by
unnecessary excessive removal of dentin and
creation of microcrack
Current rotary file systems are effective tools.
Nevertheless they have two main
shortcoming:-
A- They are unable to effectively clean and
shape the oval canals and depend too much on
irrigant to do cleaning
B- The long term survival of the tooth is by
unnecessary excessive removal of dentin and
creation of microcrack
Is a shaping and cleaning system designed
for minimally invasive endodontic
treatment
 The new SAF technology uses a hollow
compressible Niti file, with no central metal
core , through which a continuous flow of
irrigant is provided
 The SAF has lattice like design makes the
instrument extremely flexible in all three
dimentions to fit the cross section of the canal
at any vertical location
 The SAF is the first file that does not have a
solid metal shaft is designed as a hollow tube
with rough outer surface
 This technology uses a new concept
of cleaning and shaping in which a
uniform layer of dentin is removed
from the root canal thus avoiding
unnecessary excessive removal of
dentin
 The SAF allow for effective cleaning of all
root canals including oval canals, thus
allowing for effective disinfection and
obturation of all canal morphologies
 The SAF is avaliable in three standard
lengths (21mm,25mm,31mm) and two
diameters (1.5mm,2.0mm)
1- SAF System:- include the VATEA
peristaltic irrigation device and RDT hand
piece
 RDT hand piece operates the SAF with
0.4mm amplitude vertical vibration and
designed to be operated at 5,000 rpm
 RDT hand piece heads the only hand piece
that provide the combined motion of vertical
vibration and rotation required for proper
operation of SAF
 The RDT hand piece is designed to sustain
prolonged exposure to sodium hypochlorite
The VATEA system is a self contained fluid
delivery unit intended to deliver irrigant
solution during endodontic procedure
 The irrigant is delivered via a disposable
silicone tube
 The flow of irrigant toggled by using a foot
pedal and the operator can adjust the flow rate
by using -/+ push buttons
2-SAF proSystem:- include the endostation
endodontic motor
The Endostation is a multi functional
endodontic motor that enable the user to
operate various endodontic system including
SAF and all major brands of rotary and
reciporcating file
 The Endostation include peristaltic pump and
irrigation system
The irrigation system are operated by foot
pedal
 A large LCD screen and audio are used to
indicate the flow rate , working time and
battery status
When comparing with other rotary system there is
economic value thanks to the SAF because of
the additional clinical benefits including
avoidance of post operative pain, highly
efficient endo treatment, the ability of improved
cleaning and disinfection in short time with less
risk and less complication
The self adjusting file system / Dr.sarah alkhateeb

The self adjusting file system / Dr.sarah alkhateeb

  • 1.
    Done by: Dr sarahabd alsalam Supervised by: Dr Ban
  • 3.
    Rotary nickel titaniumwere first introduced clinically in 1993 in represent a real shift in endodintic New design have been introduced over the years attempting to make these instrument more efficient, more flexible and safer in the term of file seperation
  • 4.
    Current rotary filesystems are effective tools. Nevertheless they have two main shortcoming:- A- They are unable to effectively clean and shape the oval canals and depend too much on irrigant to do cleaning B- The long term survival of the tooth is by unnecessary excessive removal of dentin and creation of microcrack Current rotary file systems are effective tools. Nevertheless they have two main shortcoming:- A- They are unable to effectively clean and shape the oval canals and depend too much on irrigant to do cleaning B- The long term survival of the tooth is by unnecessary excessive removal of dentin and creation of microcrack
  • 5.
    Is a shapingand cleaning system designed for minimally invasive endodontic treatment
  • 6.
     The newSAF technology uses a hollow compressible Niti file, with no central metal core , through which a continuous flow of irrigant is provided
  • 8.
     The SAFhas lattice like design makes the instrument extremely flexible in all three dimentions to fit the cross section of the canal at any vertical location
  • 10.
     The SAFis the first file that does not have a solid metal shaft is designed as a hollow tube with rough outer surface
  • 13.
     This technologyuses a new concept of cleaning and shaping in which a uniform layer of dentin is removed from the root canal thus avoiding unnecessary excessive removal of dentin
  • 14.
     The SAFallow for effective cleaning of all root canals including oval canals, thus allowing for effective disinfection and obturation of all canal morphologies
  • 18.
     The SAFis avaliable in three standard lengths (21mm,25mm,31mm) and two diameters (1.5mm,2.0mm)
  • 20.
    1- SAF System:-include the VATEA peristaltic irrigation device and RDT hand piece
  • 21.
     RDT handpiece operates the SAF with 0.4mm amplitude vertical vibration and designed to be operated at 5,000 rpm
  • 22.
     RDT handpiece heads the only hand piece that provide the combined motion of vertical vibration and rotation required for proper operation of SAF
  • 23.
     The RDThand piece is designed to sustain prolonged exposure to sodium hypochlorite
  • 25.
    The VATEA systemis a self contained fluid delivery unit intended to deliver irrigant solution during endodontic procedure
  • 26.
     The irrigantis delivered via a disposable silicone tube  The flow of irrigant toggled by using a foot pedal and the operator can adjust the flow rate by using -/+ push buttons
  • 28.
    2-SAF proSystem:- includethe endostation endodontic motor The Endostation is a multi functional endodontic motor that enable the user to operate various endodontic system including SAF and all major brands of rotary and reciporcating file
  • 29.
     The Endostationinclude peristaltic pump and irrigation system The irrigation system are operated by foot pedal
  • 30.
     A largeLCD screen and audio are used to indicate the flow rate , working time and battery status
  • 35.
    When comparing withother rotary system there is economic value thanks to the SAF because of the additional clinical benefits including avoidance of post operative pain, highly efficient endo treatment, the ability of improved cleaning and disinfection in short time with less risk and less complication