This document provides a summary of Reymondo H. Alcantara's work experience and qualifications. It details his 26 years of experience in the power industry, including current work as a High Voltage Testing Officer for SA Power Networks. Previous roles include positions with ETSA Utilities, National Transmission Corporation, and National Power Corporation in the Philippines. He holds an MBA and Bachelor's in Mechanical Engineering, as well as industry certifications. Contact details and references are also provided.
ELECTRICAL ENGINEER WITH 13 YEARS OF EXPERIENCEEBRAHIM KHALIL
Bachelor of Electrical Engineering with 13 years of experience in Maintenance, Operation, Inspection, Commissioning, Protection, condition monitoring and coordination work of Electrical Maintenance.
ELECTRICAL ENGINEER WITH 13 YEARS OF EXPERIENCEEBRAHIM KHALIL
Bachelor of Electrical Engineering with 13 years of experience in Maintenance, Operation, Inspection, Commissioning, Protection, condition monitoring and coordination work of Electrical Maintenance.
An Electrical Engineer & A competent professional with near about 9 years of experience in the field of engineering, testing & commissioning of electrical & automation projects & maintenance of steel plant (Coke making plant).
Expertise in managing maintenance operations for reducing breakdown / downtime & enhancing operational effectiveness of equipment's.
An effective communicator with excellent relationship management skills and strong analytical, leadership, decision making, problem solving & organizational abilities.
I am seeking Project Manager / Project Engineering work opportunities which will utilize my varied experience with utility power delivery projects and medium voltage manufacturing projects including engineering, design, and construction management.
While most analysts call for speeds of 100 Mbps to enable multiple streams of HDTV, Wayne says that's shortsighted. This 2006 presentation helps justify fiber-to-the-home and gigabit speeds with examples of applications that need that performance.
An Electrical Engineer & A competent professional with near about 9 years of experience in the field of engineering, testing & commissioning of electrical & automation projects & maintenance of steel plant (Coke making plant).
Expertise in managing maintenance operations for reducing breakdown / downtime & enhancing operational effectiveness of equipment's.
An effective communicator with excellent relationship management skills and strong analytical, leadership, decision making, problem solving & organizational abilities.
I am seeking Project Manager / Project Engineering work opportunities which will utilize my varied experience with utility power delivery projects and medium voltage manufacturing projects including engineering, design, and construction management.
While most analysts call for speeds of 100 Mbps to enable multiple streams of HDTV, Wayne says that's shortsighted. This 2006 presentation helps justify fiber-to-the-home and gigabit speeds with examples of applications that need that performance.
1. REYMONDO H. ALCANTARA
HV Testing Officer
SA Power Networks
17 Talbot Ave., North Plympton, South Australia 5037
Work Mobile No: +61 409094604
Personal Mobile No: +61 0403414311
Email address:reymondo.alcantara@sapowernetworks.com.au
: rheyjs@hotmail.com
--------------------------------------------------------------------------------------------
Field of specialcompetence
26 years of experience in Power Industry with a record of accomplishment in engineering and supervisory positions
in high voltage electrical power equipment, diagnostic testing, commissioning and maintenance. Currently involve
in High Voltage Testing of ElectraNet 275, 132, 66 & 11kV high voltage electrical power equipment. Perform high
voltage testing and maintenance of 500, 230, 69 and 13.8kV electrical power equipment of National Power
Corporation in the Philippines. Pioneer in the Commissioning, Operation and Maintenance of 5 X 30 MW Gas
Turbine Power Plant Barges in the Philippines. Work in 640 MW Oil Fired Thermal Power Plant, particularly in the
operation and maintenance of auxiliary power equipment. Involve in the procedure writings of high voltage
electrical power equipment purposely for ISO 9001 certification.
ProfessionalExperiences
South Australia Power Networks – 26 March 2012 – Present; South Australia Power
Networks
High Voltage Testing Officer - Construction and Maintenance Services
Accountability Statement
• Conduct testing of HV plant and equipment, providing related expert technical advice to ensure continuous
and safe operation of SA Power Networks distribution network / External customers HV plant and
equipment to a required level.
• Ensure operational compliance with SA Power Networks Utilities OHS&W and Environmental Systems.
• Follow leadership, and assist with supervision of employees & external service providers / customers.
• Understand and assist in key customer relationships to ensure that agreed services are delivered.
2. • Interpreting test results adherence to statutory authorities/legislation and ensure compliance with regulatory
standards are met to required level.
• Participate and assist in reviewing the performance of the work group against agreed KPIs to a required
level as set by the Substation Maintenance Operations Manager.
• Assist in planning and coordinating the work to meet the work group budget category requirements.
• Ensure cost effective use of internal & external resources to met job requirements.
• Coordinating changes to work priorities due to abnormal conditions, emergencies and interaction with other
internal work groups / external customers to a required level.
ETSA Utilities – 18 January 2010 – 23 March 2012
High Voltage Technician – Field Services
Accountability Statement
• Conduct testing of HV plant and equipment, providing related expert technical advice to ensure continuous
and safe operation of SA Power Networks distribution network / External customers HV plant and
equipment to a required level.
• Ensure operational compliance with SA Power Networks Utilities OHS&W and Environmental Systems.
• Follow leadership, and assist with supervision of employees & external service providers / customers.
• Understand and assist in key customer relationships to ensure that agreed services are delivered.
• Interpreting test results adherence to statutory authorities/legislation and ensure compliance with regulatory
standards are met to required level.
• Participate and assist in reviewing the performance of the work group against agreed KPIs to a required
level as set by the Substation Maintenance Operations Manager.
• Assist in planning and coordinating the work to meet the work group budget category requirements.
• Ensure cost effective use of internal & external resources to met job requirements.
• Coordinating changes to work priorities due to abnormal conditions, emergencies and interaction with other
internal work groups / external customers to a required level.
ETSA Utilities – 9 January 2006 – 15 January 2010
System Electrician - Construction and Maintenance Services
Power SystemMaintenance Department – North
Equipment Test and Diagnostic Section (ETDS)
HV Testing Engineer
National Transmission Corporation – March 16, 1993 – December 29, 2005.
ETDS of PSMD-N is engaged in conducting preventive maintenance, commissioning, acceptance testing of 500,
230, 69 & 13.8 KV electrical power equipment of Northern Luzon Operation and Maintenance including technical
services to power customers and private electric cooperatives.
Principal Engineer. B, Equipment Test and Diagnostics Section,
(Poro Pt., San Fernando City, 2500 La Union, Philippines)
Responsible for the implementation of maintenance and testing of power equipment appurtenances to ensure quality
and timely test service, safe, reliable and efficient power equipment operating conditions including but not limited to
the following:
• Leads the team in the implementation of:
• Preventive maintenance and diagnostic testing of various power equipment and appurtenances.
• Pre-energisation inspection test and commissioning of newly installed power equipment and
appurtenances at power plants and substations.
• Thermal Scanning of substation equipment and transmission lines.
3. • Repair, troubleshooting and corrective maintenance and testing of power equipment.
• Acceptance testing of new power equipment.
• Correct application of test methods and procedures.
• Emergency testing and restoration of power.
• Updating of single line diagrams, drawing and plans.
• Approved corporate and office policies, guidelines, rules and regulations.
• Job and work orders for the revisions and upgrading of power equipment.
• Technical Services to power customers and private electric utilities.
2.0 Investigates and evaluates:
• Test results and interruption reports.
• Failure / breakdown and trouble / abnormalities of power equipment.
• Hotspots oftransmission lines and substation powerequipment.
3.0 Plans work schedule of the team in:
• Maintenance check-up and repair of testing instruments.
- Laboratory testing.
• Corrective maintenance and testing of power equipment.
• Updating of maintenance records and equipment statistics.
• Conduct of Job Enrichment Program.
4.0 Study computes and recommends to Principal Engineer A:
• Tolerable operating limits and criteria in testing of power equipment.
• Revisions, upgrading, repair and / or replacement of power equipment and scheme.
• New test methods and procedures.
• Prepares and submits for recommending approval to the
Principal Engineer A:
• Historic graphical analysis chart of power equipment.
• Test and accomplishment reports of the team.
• Record of power equipment with conditional test results,troubles and abnormalities.
6.0 Performs other duties as maybe assigned.
Special Skills:
• Commissioning test of BAY 4 power equipment @ Santiago Substation, e.g. 50MVA power transformer,
Bushing Current Transformers, Gas Circuit Breakers (84ST4 / 124 / 8) and associated Lightning Arresters.
Including SF6 gas filling retrieving, conditioning / degassing / filtering of all GCBs under PSMD-N area of
responsibility.
• Commissioning test of BAY 2 power equipment @ Tuguegarao Substation, e.g., 50MVA power transformer,
Bushing Current Transformers, Gas Circuit Breakers (82TG4 and 124) and associated Lightning Arresters.
• Commissioning test of BAY 6 & 7 Power equipment @ San Manuel Substation, e.g., 50MVA power
transformer, Bushing Current Transformer, Gas Circuit Breakers (86SM4 / 124 / 8 and 87SM4 / 124 / 8),
Capacitive Voltage Transformers and Lightning Arresters.
Testing Equipment Utilized:
AC / DC insulation testers (C & DF):
• Megger Delta 2000
• Doble power factor tester(M4100)
• Biddle power factor tester
4. • CPC 100, Omicron
• HVA60 (VLF Testerfor power cables)
Ratio Testers:
• CPC 100, Omicron
• CTER 91 and Tettex Ratiometer
• CT Analyzer with CT SB2 attached
Breaker Motion analyzer:
• Vanguard and Programma
SF6 gas analyzer:
• DILO Moisture and Purity analyzer
• SF6 Cart for evacuating,filling suctioning and purifying of SF6 gas.
SFRA / Partial Discharge (PD)
• Doble M5400
• Doble PD Smart
DC Winding Resistance Tester
• DV Power RMO60TD
Integrated Barge Management Group
National Power Corporation – June 1990 – March 15, 1993
5 X 30 MW Gas Turbine Power Plant Barges, stationed at Navotas Fish Port Complex to augment power supply
during the power crisis in the Philippines.
Acting Principal Engineer A, Operation and Maintenance (Navotas Fish Port Complex, Navotas,
Philippines)
Directed activities of operation personnel for the safe, reliable, and correct operating procedures and maintenance of
Gas Turbine Power Barges. Supervise and implement scheduled periodic maintenance of mechanical, electrical and
auxiliary power equipment.
Malaya Thermal Power Plant
National Power Corporation – April 13, 1989 – May 31, 1990
640 MW Thermal Power Plant, Located at the province of Pililia. Rizal, Philippines.
Equipment Operator C, Auxiliary power equipment operator, e.g. main steam condenser circulating pump,
Gas recirculation fan of Boiler, Boiler feed pump. Manual cleaning of Boiler burner tip, screen house and Bunker oil
fuel pump house operator.
Report abnormalities / trouble to the shift-in-charge for immediate corrective action and Responsible for the routine
check-up of auxiliary power equipment to ensure reliable, efficient and safe operation.
Training Programs / Seminars Attended
Title of Seminars / Trainings Inclusive dates # of
Hours
Sponsored by
5. 1.0 Partial Discharge Measurement 17th Nov. 2015 8 OMICRON
1.0a
CPR
09-02- 2015
2
ANFAS
2.0
Power Equipment Electrical Testing
May 22-23, 2003
16
TransCo – HRD
3.0 AC / DC Systems May 20-21, 2003 16 TransCo – HRD
4.0 Supervisory Development Course Feb. 4-7, 2003 32 TransCo-HRTD
5.0
Instrumentation & Process Control
Course
Nov. 11-15,2002 40 UP – ISSI
6.0
Options, Opportunities & Personal
Success
NPC – HRTDD Oct.
14-15, 2002
16 TransCo – TDC
7.0 Power Systems Maintenance Oct. 16-19, 2001 32 TransCo.-PSMD
8.0 Communications System Training Aug. 9-10, 1999 16 NPC – HRTDD
9.0
Quality Management System
Training
Aug. 16-17,1999 16 NPC – HRTDD
10.0 AC / DC Systems Training July 5-6, 1999 16 NPC – HRTDD
11.0 Protective Relaying Training July 12-13,1999 16 NPC – HRTDD
12.0 Power Metering Training July19-20,1999 16 NPC – HRTDD
13.0
Siemens Range of HV Power Circuit
Brakers
Nov. 16 – 18, 1998 24 Siemens
14.0
Remote E-mail & Intro to INS Power
Point
Nov. 24 – 25, 1997 15 NPC – HRTDD
15.0
MRP – Integrity Circles
TeambuildingWorshop
July 7 – 11, 1997 40 OP – MRP
16.0
Tool Management & Safety Seminar
Feb. 1, 1997 8
Sanvik –
Philippines
17.0
MMP – Development Orientation
Seminar
Sept. 3, 1996 8 NPC-MMP/OMP
18.0 Welding Inspector Course June 17-72, 1996 72 NPC – HRTDD
19.0 Seminar on Precision Measurement May 27 – 31, 1996 40 NPC – HRTDD
20.0 SKF Microlog Users Workshop Aug. 29-31, 1995 16 SKF-Philippines
21.0 Defensive Driving Course May 15–17, 1995 24 NPC – HRTDD
22.0
HV-Eqpt. Opt’n. & Maintenance
Seminar
Nov. 21-25, 1994 40 NPC – HRTDD
23.0 Disaster Control Brigade Training Sep. 19-24, 1994 48 NPC – HRTDD
24.0
Opt’n. Mgmt. Program Procedure
Development Course
Aug. 25-26, 1993 16 NPC – NEG
25.0
OJT on Testing / Commissioning /
Operation of Gas Turbine Power
Barges
Oct. 1 – Dec. 31,
1990
580 NPC - IBMG
26.0
OJT on Testing / Commissioning /
Operation of Gas Turbine Power
Barges
July 1 – Sep 30, 1990 572 NPC - IBMG
27.0
OJT on Navotas Gas Turbine Power
Barges
May 22 – June 22,
1990
192 NPC – HRODD
28.0
OJT on Thermal Power Plant
Operation
April 24 – May 5,
1989
72 NPC – HRODD
29.0
OJT on Sucat Thermal Power Plant April 10 – May 28,
1987
300
NPC – Sucat
Thermal
6. Qualifications and affiliations
Certificate III in Electro technology SystemElectrician, TAFE, Regency Campus, South Australia
Electrician Class A – License No. PGE239429
High Voltage Switching License – C2 License No. 502084
Level 3 Substation Access License
Certificate IV in Frontline Management
Master in Business Administration degree, Philippine Christian University, 1648 Taft Ave., cor. Pedro Gil.,
Manila, Philippines
P.O. Box 907, Manila
(Recognised by Dept. of Further Education – Gov. of South Australia)
Bachelor of Science in Mechanical Engineering, Don Mariano Marcos Memorial State University,
Catbangen, San Fernando City, 2500 La Union, Philippines.
(Recognised by Dept. of Further Education – Gov. of South Australia)
Referees:
Jun Rayo
HV Test Supervisor - CaMS
SA Power Networks
Mobile Phone: +618 0409783890
Andrew Lambourne
Technical Delivery Manager
SA Power Networks
Mobile Phone: +618 0428100432