The PCME QAL 991 is an approved particulate continuous emissions monitoring system that can connect up to 32 sensors to a single control unit. It is designed to meet and exceed CEN standards for particulate monitoring. The system performs automatic self-checks including zero and span checks to assess accuracy and record data for quality assurance level 3 reporting. It provides accurate emissions monitoring and satisfies regulatory testing requirements.
The Serinus 40 Oxides of Nitrogen analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology to measure NO, NO2 and NOx in ambient air (LDL <0.4 ppb, range 0-20 ppm).
The Serinus 40 Oxides of Nitrogen analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology to measure NO, NO2 and NOx in ambient air (LDL <0.4 ppb, range 0-20 ppm).
The Serinus 50 Sulfur Dioxide (SO2) analyser delivers precise and reliable performance at excellent value. It uses proven pulsed UV fluorescent radiation technology to measure SO2 in ambient air (LDL <0.3 ppb, Range 0-20 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Serinus 40 Oxides of Nitrogen analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology to measure NO, NO2 and NOx in ambient air (LDL <0.4 ppb, range 0-20 ppm).
The Serinus 40 Oxides of Nitrogen analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology to measure NO, NO2 and NOx in ambient air (LDL <0.4 ppb, range 0-20 ppm).
The Serinus 50 Sulfur Dioxide (SO2) analyser delivers precise and reliable performance at excellent value. It uses proven pulsed UV fluorescent radiation technology to measure SO2 in ambient air (LDL <0.3 ppb, Range 0-20 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Exactus BAM is a real-time beta gauge built to satisfy users, regulators and those from the health community by providing truly accurate, precise, real time measurement of fine particulate matter automatically, it is a permanent installation with the capacity to be portable when needed.
FEATURES & SPECIFICATIONS
Real-time, accurate results without correction factors, regardless of season or geographic location
True ambient sampling provides accurate measurement of semi-volatile nitrates and organic compounds
Lightweight, rugged construction is easily mounted on a tripod in minutes
All-weather construction allows for true ambient sampling
Operates on AC power.
Sensor Cartridge SC2 for combustible gases
Exchangeable sensor including digital value processing, temperature compensation and self control for the continuous monitoring of the ambient air.
The sensor cartridge SC2 includes a Pellistor sensor element and an amplifier as well as a μController for measured values processing. All important data and measured values of the sensor element are stored fail-safe in the μController and transmitted digitally via the local bus to the sensor board SB2 or MSB2. The calibration management is also integrated in the μController of the sensor cartridge.
Calibration is done either by simply replacing the sensor cartridge or by using the comfortable, integrated calibration routine directly at the system.
APPLICATION
The PolyGard®2 Sensor Cartridge is used for the detection of combustible gases in non-Ex zones.
FEATURES
Digital measurement value processing incl. temperature compensation
Internal functional control with integrated Hardware Watchdog
Data / measured values in μC Sensor Cartridge, therefore simple exchange of SC uncalibrated <> calibrated
High accuracy, selectivity and reliability
Low zero point drift
Sensor with long life expectancy
Hardware & software according to SIL2 compliant development process
Modular technology (plug-in and replaceable)
Easy maintenance and calibration by exchange of the sensor cartridge or by comfortable on-site calibration
For integrated, cost effective moisture analysis for OEM’s and multiple sampling points. When simple, accurate moisture
measurement is required, the MM300 is the ideal choice.
Designed with the OEM user in mind, the MM300 transducer and monitor can be easily integrated into a wide range of systems.
The project was an embedded system project, where an alarm will go on whenever an inbuilt sensor sense any gas around it. Project describes the software simulation and also the working circuit which was used to implement the circuit on a board by incorporating all the required elements.
The PrevEx is flammability analyzer is used to determine lower flammable limit monitoring (LFL/LEL) to sense and protect against the accumulation of combustible and hazardous vapors.
The main aim of this project is to avoid the accident and death in the gas leakage explosion in house, hotels and industries. Domestically we use natural gas and it is very useful for burning purpose. If this gas is leaked in our kitchens, hotels or factories and not sensed in time, it may lead to fatal disaster, and may cause human and material loss. For this purpose we have developed “GAS LEAKAGE DETECTION SYSTEM”.
The Serinus 44 analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology and an external thermal catalytic converter to measure NO, NO2, NOx and NH3 in ambient air (LDL < 0.4 ppb, Range 0 – 20 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 40 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
In This PPT we are discussed about complete details of that product (Use,Operation, Technical details, Dimensions, Wiring, and etc..)
Please Support us and Follow our other Sites
https://automationtechplc2.blogspot.com
https://humidificationcontrol.blogspot.com
https://controlsandsystems.business.site
If you enjoyed this article, share it with your friends and colleagues
GCEM 40 series extractive gas analyser codel datasheetENVIMART
GCEM 40 series extractive gas analyser codel datasheet - CODEL - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
The HY-OPTIMA™ 1700 is an intrinsically safe device that incorporates our patented solid-state sensor and is configured to operate in background gas streams with up to 95% relative humidity and temperatures up to 100ºC.
The environmental sensor can monitor temperature, Humidity and airflow allowing for real-time monitoring of critical environmental operations.
Up to 6 sensors can be daisy chained to one iPDU. Each sensor has a battery backed clock and can store its own readings therefore there are no data login delays.
The sensors generate events when user defined thresholds are broken, and the events are communicated via e-mail or SNMP traps (SMS optional)
Live readings for temperature, humidity and airflow
Web admin interface
Reports on historical environment behavior
User defined thresholds to trigger alarms and actions
e-mail alerts (SMS optional)
Sensors positioned at rack level or room level
Specifications:
- Battery backed clock
- E-mail, SNMP traps
- Temperature readings in Celsius, Fahrenheit or Kelvin
- Humidity sensor included
- Airflow sensor included
- Temperature range: -45 °C to +115 °C
(-67°F to +104 °F, 218 °K to 398°K)
- Temperature accuracy: 1.2 °C
- Humidity range: 0 to 100% RH
- Humidity accuracy: 4%
Fluke Data Acquisition System Selection Guide. Hubungi PT. Siwali Swantika 02...PT. Siwali Swantika
Datasheet Fluke 1586A Super-DAQ. Datasheet Fluke 2638A Hydra Series III. Informasi lebih detail hubungi PT. Siwali Swantika, Jakarta Office : 021-45850618 atau Surabaya Office : 031-8421264
The Exactus BAM is a real-time beta gauge built to satisfy users, regulators and those from the health community by providing truly accurate, precise, real time measurement of fine particulate matter automatically, it is a permanent installation with the capacity to be portable when needed.
FEATURES & SPECIFICATIONS
Real-time, accurate results without correction factors, regardless of season or geographic location
True ambient sampling provides accurate measurement of semi-volatile nitrates and organic compounds
Lightweight, rugged construction is easily mounted on a tripod in minutes
All-weather construction allows for true ambient sampling
Operates on AC power.
Sensor Cartridge SC2 for combustible gases
Exchangeable sensor including digital value processing, temperature compensation and self control for the continuous monitoring of the ambient air.
The sensor cartridge SC2 includes a Pellistor sensor element and an amplifier as well as a μController for measured values processing. All important data and measured values of the sensor element are stored fail-safe in the μController and transmitted digitally via the local bus to the sensor board SB2 or MSB2. The calibration management is also integrated in the μController of the sensor cartridge.
Calibration is done either by simply replacing the sensor cartridge or by using the comfortable, integrated calibration routine directly at the system.
APPLICATION
The PolyGard®2 Sensor Cartridge is used for the detection of combustible gases in non-Ex zones.
FEATURES
Digital measurement value processing incl. temperature compensation
Internal functional control with integrated Hardware Watchdog
Data / measured values in μC Sensor Cartridge, therefore simple exchange of SC uncalibrated <> calibrated
High accuracy, selectivity and reliability
Low zero point drift
Sensor with long life expectancy
Hardware & software according to SIL2 compliant development process
Modular technology (plug-in and replaceable)
Easy maintenance and calibration by exchange of the sensor cartridge or by comfortable on-site calibration
For integrated, cost effective moisture analysis for OEM’s and multiple sampling points. When simple, accurate moisture
measurement is required, the MM300 is the ideal choice.
Designed with the OEM user in mind, the MM300 transducer and monitor can be easily integrated into a wide range of systems.
The project was an embedded system project, where an alarm will go on whenever an inbuilt sensor sense any gas around it. Project describes the software simulation and also the working circuit which was used to implement the circuit on a board by incorporating all the required elements.
The PrevEx is flammability analyzer is used to determine lower flammable limit monitoring (LFL/LEL) to sense and protect against the accumulation of combustible and hazardous vapors.
The main aim of this project is to avoid the accident and death in the gas leakage explosion in house, hotels and industries. Domestically we use natural gas and it is very useful for burning purpose. If this gas is leaked in our kitchens, hotels or factories and not sensed in time, it may lead to fatal disaster, and may cause human and material loss. For this purpose we have developed “GAS LEAKAGE DETECTION SYSTEM”.
The Serinus 44 analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology and an external thermal catalytic converter to measure NO, NO2, NOx and NH3 in ambient air (LDL < 0.4 ppb, Range 0 – 20 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 40 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
In This PPT we are discussed about complete details of that product (Use,Operation, Technical details, Dimensions, Wiring, and etc..)
Please Support us and Follow our other Sites
https://automationtechplc2.blogspot.com
https://humidificationcontrol.blogspot.com
https://controlsandsystems.business.site
If you enjoyed this article, share it with your friends and colleagues
GCEM 40 series extractive gas analyser codel datasheetENVIMART
GCEM 40 series extractive gas analyser codel datasheet - CODEL - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
The HY-OPTIMA™ 1700 is an intrinsically safe device that incorporates our patented solid-state sensor and is configured to operate in background gas streams with up to 95% relative humidity and temperatures up to 100ºC.
The environmental sensor can monitor temperature, Humidity and airflow allowing for real-time monitoring of critical environmental operations.
Up to 6 sensors can be daisy chained to one iPDU. Each sensor has a battery backed clock and can store its own readings therefore there are no data login delays.
The sensors generate events when user defined thresholds are broken, and the events are communicated via e-mail or SNMP traps (SMS optional)
Live readings for temperature, humidity and airflow
Web admin interface
Reports on historical environment behavior
User defined thresholds to trigger alarms and actions
e-mail alerts (SMS optional)
Sensors positioned at rack level or room level
Specifications:
- Battery backed clock
- E-mail, SNMP traps
- Temperature readings in Celsius, Fahrenheit or Kelvin
- Humidity sensor included
- Airflow sensor included
- Temperature range: -45 °C to +115 °C
(-67°F to +104 °F, 218 °K to 398°K)
- Temperature accuracy: 1.2 °C
- Humidity range: 0 to 100% RH
- Humidity accuracy: 4%
Fluke Data Acquisition System Selection Guide. Hubungi PT. Siwali Swantika 02...PT. Siwali Swantika
Datasheet Fluke 1586A Super-DAQ. Datasheet Fluke 2638A Hydra Series III. Informasi lebih detail hubungi PT. Siwali Swantika, Jakarta Office : 021-45850618 atau Surabaya Office : 031-8421264
Input van de organisatie voor het opbouwen van actieve support van het Ministerie van Economische Zaken voor het Zero Budget Innovatie 2.0 Co-Creatie event op 27 mei 2009.
Industrial monitoring and control systems using andriod applicationAvinash Vemula
Automation takes the complete control of total plants few authentication and manual actions are needed from user side for completing action .Hence there is a must situation for users presence at all times in the control for taking some timely needed control actions. The proposed system provides a good solution to this problem. The whole control room environment is additionally implemented in the arm-android platform and the same is communicated to the process through Bluetooth. Now the user in control can use mobile at anytime, anywhere to monitor and control the whole plant.8051 is used here for acquiring process control parameters from the sensors like temperature, gas etc and transmitting it via a Bluetooth module to an android device. Hence the parameter values can be monitored and stored simultaneously.
The Serinus 10 Ozone (O3) analyser delivers precise and reliable performance at excellent value. It uses proven non-dispersive ultraviolet (UV) absorption technology to measure O3 in ambient air (LDL < 0.5 ppb, range 0 – 20 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
Spec sheet Cemtek Model 1000 Oxygen MonitorBrian Gilmore
Key Features:
• Modular probe design with blowdown ideal for high dust,
corrosive applications
• FM Approved
• Ease of maintenance with no probe removal to replace
element
• Combustion efficiency mode available as option
• Remote control of calibration and blowdown routines via
digital inputs
• Detector sensor replacement and maintenance is half
the cost of equivalent competitive products
https://www.linkedin.com/pub/brian-gilmore/4/705/238
Precise control of low O2 set points with confidence.
CO detection for control interlocks and safety shutdown.
Predictive diagnostics
SIL 2 capable for SIS implementation of IEC 61508/61511 into the burner management system.
The reliable identification of low combustion oxygen in a red heater or boiler has always been critical to the effectiveness of the Burner Management System for proper control and safety.
Low emission burners and aggressive ring control points to achieve increased efficiency and emission reductions have driven the industry to tighter control measures. But tighter control measures also hold a greater potential for combustion damage. Reducing the risk of a combustion event has become a priority and has led to the implementation of Safety Instrumented Systems (SIS). This additional layer of safety is added to the Basic Process Control System.
Hệ thống quan trắc khí thải tự động - Tư vấn: 0938-564-123Lâm Nguyễn Hoàng
Hệ thống quan trắc khí thải tự động cho chủ nguồn thải khí thải công nghiệp - Tư vấn đầu tư lắp đặt: lam.nguyen@vietan-enviro.com - 0938-564-123 (Mr Lâm)
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzersENVIMART
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzers - ABB - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
The IQ SensorNet is a continuous water quality monitoring solution. Monitor and control to improve your process. This overview explains the water quality parameters you can measure and how you can build a network of sensors and instruments. http://www.ysi.com/iq
GCEM 40 series gas analyser insitu-codel datasheetENVIMART
GCEM 40 series gas analyser insitu-codel datasheet - CODEL - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
Oxymax cos51 d endress+hauser datasheet-measurement of the dissolved oxygenENVIMART
Oxymax cos51 d endress+hauser datasheet-measurement of the dissolved oxygen - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
Digital sensor for measuring dissolved oxygen. Longterm-stable sensor for water and wastewater applications. . Email: lam.nguyen@vietan-enviro.com HP: 0945 293292
Designed to provide thorough, continuous monitoring of many hazardous gases, the indoor/outdoor Ultima X Series Gas Monitors offer excellent performance and MSA quality craftsmanship. DuraSource™ Technology offers extended sensor life, while HART provides convenient setup, calibration and diagnostics. HART also allows for existing component install and wiring to be used. A single circuit board increases reliability, while our patented sensor disconnect-underpower feature allows all sensors to be replaced in hazardous areas without area declassification. The units are crafted from either stainless steel or polycarbonate, and the interchangeable smart sensors eliminate the need for reconfiguration. Our scrolling LCD screen display sensor reading and gas type, while the calibration process includes date stamping and the ability to calibrate locally or remotely.
Learn about a1-cbiss' refrigeration solutions that cover everything from refrigerant leak detection and monitoring through to emissions control in this brochure
Ideal for oil exploration and extraction the MSA Ultrasonic Gas Detector offers a wide range of detection information. Find out more in this datasheet prepared by gas detection specialists a1-cbiss.
1. PCME QAL 991
Particulate Monitoring System
The PCME QAL 991 is an approved
Particulate CEM (Continuous Emission
Monitor) designed to meet and exceed CEN
standard EN 14181 / EN 13284-2
KEYBENEFITS
The instrument design permits up to 32 sensors to be connected to a
•
sensors and industry standard outputs are provided for easy connection
single central control unit. The control unit provides power for the
Unaffected by contamination on the
to plant control systems.
sensor rod
•
Highly Accurate Emissions Data
the BTU index (gas calorific value, only
The instrument’s automatic self-checks are extended to provide
with syngas analysers)
zero, span and contamination tests which assess uncertainty and to
The results of the automatic upscale
record results for later statistical analysis. This provides the
(span) check can optionally be used
infrastructure for QAL3 tests according to EN-14181.
to compensate for the effects of any
Satisfy QAL3 Requirements
contamination
•
System self-checks, with logging of
Zero and Span check data for QAL3
reporting
Optional PC software ‘QAL Reporter’ provides secure emissions and
QAL3 reporting. It includes the statistical treatment of the zero and span
results for the user to demonstrate that the instrument is operating
according to defined specifications (uncertainty).
“
QAL 991 is an approved
Particulate Measurement System for
compliance monitoring
“
•
On-board Calculation and display of
2. TECHNICALSPECIFICATION
TEMPERATURE
• Temperature Range: Stack temperature 0-250oC
Stack temperature 0-400oC (option)
SPAN & DRIFT
• Long term zero drift: <0.1mg/m3.
• ELV Range (Emission Limit Value): 0 - 10 mg/m3 to 0 - 100
mg/m3
• Minimum Detection Level: <0.1 mg/m3
• Resolution: 0.01 mg/m3
POWER
• Output: RS-485/MODBUS to control unit
• Power: 24V DC (Provided by control unit)
• Process Conditions: Non-condensing
CERTIFIED RANGES
• Certification range: 0 -15mg/m3 (QAL1 approval)
• Extended certification range: 0-100mg/m3
(QAL1 approval)
• Measurement capability: 0-300mg/m3
PHYSICAL
• Insertion of interaction volume into stack: 15mm to
600mm (user adjustable)
• Minimum stack diameter: 250mm
• Ingress protection: IP65
Complete Project Solutions
Our complete project solutions are developed to assist you
in IED compliance. We achieve this through;
•
•
•
•
•
Expert consultancy
Project management
In-house project design & build
Installation & commissioning
After product service & support
11 Ark Royal Way, Lairdside Technology Park, Tranmere, Wirral, CH41 9HT
T: +44(0)151 666 8300 F: +44(0)151 666 8329 E: sales@a1-cbiss.com
W: www.a1-cbiss.com Buy Online: shop.a1-cbiss.com
Find a1-cbiss on:
Cert No. 996
ISO 9001