The Serinus 40 Oxides of Nitrogen analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology to measure NO, NO2 and NOx in ambient air (LDL <0.4 ppb, range 0-20 ppm).
The Serinus 44 analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology and an external thermal catalytic converter to measure NO, NO2, NOx and NH3 in ambient air (LDL < 0.4 ppb, Range 0 – 20 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 40 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Serinus 10 Ozone (O3) analyser delivers precise and reliable performance at excellent value. It uses proven non-dispersive ultraviolet (UV) absorption technology to measure O3 in ambient air (LDL < 0.5 ppb, range 0 – 20 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Serinus 50 Sulfur Dioxide (SO2) analyser delivers precise and reliable performance at excellent value. It uses proven pulsed UV fluorescent radiation technology to measure SO2 in ambient air (LDL <0.3 ppb, Range 0-20 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Exactus BAM is a real-time beta gauge built to satisfy users, regulators and those from the health community by providing truly accurate, precise, real time measurement of fine particulate matter automatically, it is a permanent installation with the capacity to be portable when needed.
FEATURES & SPECIFICATIONS
Real-time, accurate results without correction factors, regardless of season or geographic location
True ambient sampling provides accurate measurement of semi-volatile nitrates and organic compounds
Lightweight, rugged construction is easily mounted on a tripod in minutes
All-weather construction allows for true ambient sampling
Operates on AC power.
The Serinus 57 Total Reduced Sulfur analyser delivers precise and reliable performance at excellent value. It uses proven UV fluorescent radiation technology and an external thermal converter to measure TRS in ambient air (LDL <0.3 ppb, Range 0-10 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Serinus 44 analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology and an external thermal catalytic converter to measure NO, NO2, NOx and NH3 in ambient air (LDL < 0.4 ppb, Range 0 – 20 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 40 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Serinus 10 Ozone (O3) analyser delivers precise and reliable performance at excellent value. It uses proven non-dispersive ultraviolet (UV) absorption technology to measure O3 in ambient air (LDL < 0.5 ppb, range 0 – 20 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Serinus 50 Sulfur Dioxide (SO2) analyser delivers precise and reliable performance at excellent value. It uses proven pulsed UV fluorescent radiation technology to measure SO2 in ambient air (LDL <0.3 ppb, Range 0-20 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Exactus BAM is a real-time beta gauge built to satisfy users, regulators and those from the health community by providing truly accurate, precise, real time measurement of fine particulate matter automatically, it is a permanent installation with the capacity to be portable when needed.
FEATURES & SPECIFICATIONS
Real-time, accurate results without correction factors, regardless of season or geographic location
True ambient sampling provides accurate measurement of semi-volatile nitrates and organic compounds
Lightweight, rugged construction is easily mounted on a tripod in minutes
All-weather construction allows for true ambient sampling
Operates on AC power.
The Serinus 57 Total Reduced Sulfur analyser delivers precise and reliable performance at excellent value. It uses proven UV fluorescent radiation technology and an external thermal converter to measure TRS in ambient air (LDL <0.3 ppb, Range 0-10 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzersENVIMART
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzers - ABB - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
EL300 multi channel water controller-tethys datasheetENVIMART
EL300 multi channel water controller-tethys datasheet - Tethys - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...ENVIMART
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for nitrite - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
CCS 120 endress+hauser datasheet-sensor for total chlorineENVIMART
CCS 120 endress+hauser datasheet-sensor for total chlorine - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
GCEM 40 series extractive gas analyser codel datasheetENVIMART
GCEM 40 series extractive gas analyser codel datasheet - CODEL - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
BOD measurement biox bod measurement datasheet endress+hauserENVIMART
BOD measurement biox bod measurement datasheet - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
Our COMETS is the perfect compact ambient air monitoring station. Fully air-conditioned, automated and according to EU guidelines.
This monitoring station can be placed anywhere in critical places such as busy intersections, street canyons, temporary background stations and much more.
The compact station comes with a complete solution such as NO, NO2, NOx, CO, PM10 - PM2.5, Black Carbon and BTEX analyzer, logger and platform.
It is constructed in such a way that minimal maintenance is required. The station can work autonomously and data can be viewed, analyzed and validated remotely using our state-of-the-art logger and "air quality data platform".
The Serinus 56 Total Sulfur analyser delivers precise and reliable performance at excellent value. It uses proven UV fluorescent radiation technology and an external thermal converter to measure TS in ambient air (LDL <0.3ppb, Range 0-10 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzersENVIMART
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzers - ABB - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
EL300 multi channel water controller-tethys datasheetENVIMART
EL300 multi channel water controller-tethys datasheet - Tethys - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...ENVIMART
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for nitrite - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
CCS 120 endress+hauser datasheet-sensor for total chlorineENVIMART
CCS 120 endress+hauser datasheet-sensor for total chlorine - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
GCEM 40 series extractive gas analyser codel datasheetENVIMART
GCEM 40 series extractive gas analyser codel datasheet - CODEL - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
BOD measurement biox bod measurement datasheet endress+hauserENVIMART
BOD measurement biox bod measurement datasheet - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
Our COMETS is the perfect compact ambient air monitoring station. Fully air-conditioned, automated and according to EU guidelines.
This monitoring station can be placed anywhere in critical places such as busy intersections, street canyons, temporary background stations and much more.
The compact station comes with a complete solution such as NO, NO2, NOx, CO, PM10 - PM2.5, Black Carbon and BTEX analyzer, logger and platform.
It is constructed in such a way that minimal maintenance is required. The station can work autonomously and data can be viewed, analyzed and validated remotely using our state-of-the-art logger and "air quality data platform".
The Serinus 56 Total Sulfur analyser delivers precise and reliable performance at excellent value. It uses proven UV fluorescent radiation technology and an external thermal converter to measure TS in ambient air (LDL <0.3ppb, Range 0-10 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Siemens Ultrasonic Level Transmitter LUT400 arrangement controllers are conservative single point long-go ultrasonic controllers for constant level or volume estimation of fluids slurries and solids and high precision observing of open channel stream Ultrasonic Level Transmitter.The SITRANS LUT400 comes in three distinct models relying upon the application, level of execution and usefulness required.see more:- www.siemenstransmitter.com
Real-time spectrum analyzer RSA5000 Series
The RSA5065 real-time spectrum analyzer with real-time analysis and sweep analysis, optional vector signal analysis application software (VSA) and EMI measurement application software (EMI), with excellent performance and specifications. Its frequency range is 9kHz to 3.2GHz, and it is available with the tracking source "-TG" model, which can be widely used in enterprise R&D, factory production, education and teaching
The CAL range of temperature controllers are designed to be easy to use, low cost and reliable in the most demanding applications, including plastics, packaging, drying and laboratory equipment.
We fotograferen, scannen woningen, gebouwen, constructies voor vastgoedmakelaars, architecten, projectontwikkelaars, aannemers,...
Daarnaast maken we 360° scans, virtual tours, grondplannen, luchtfoto's met
drones, mapping en nog veel meer.
Diensten voor vastgoed
Standaard fotografie
3d scans
Virtual tours
2d vloerplannen
Drone foto -en videografie
Virtual staging
Nabewerken foto's
Vastgoed teaser videos
Diensten voor
constructies
Foto en video
3d scans
E57 files
Vloerplannen
Puntenwolken
Mesh bestanden
Trueplan
Luchtfoto's
en meer
XRF Based &Multi-Metals & Continuous Water Analyzer Xact920European Tech Serv
Process monitoring – feedback for water treatment may improve the efficiency of the treatment process – use fewer chemicals to achieve require effluent emission limits
Measurement of Se, As for compliance with Steam Electric Generating Effluent Guidelines
Monitoring of treatment of wastewater by biological based treatment systems
Measurement of Corrosion Products (e.g. Fe, Ni, Cr and Mn) to improve operating efficiency
Measurement of Elements in Nuclear Power Plant Applications (e.g. Pb, Cu, Fe)
Reduce laboratory analysis costs
On-line, in-situ, and at-line monitoring of batch and continuous processes
Displays up to 15 properties at once and measures up to 30 properties per stream
Optical multiplexing capabilities provide analysis of up to 16 process streams using fiber optic or extractive stream switching
Utilizes process-proven ANALECT® Diamond 20™ Transept™ optical head
SpectraRTS™ software engineered exclusively for on-line monitoring, allowing use by engineers, maintenance personnel, and chemists
All ANALECT® lab and on-line systems share core optical technology, allowing instrument-to-instrument calibration transfers
The FROG-5000™ is a portable gas chromatograph (GC) that identifies multiple target volatile organic compounds (VOC) in water, soil, and air. The FROG-5000™ detects chemicals as volatile as vinyl chloride to semi-volatile organics such as naphthalene with lab quality results.
Featuring a MEMS (micro electro-mechanical systems), the FROG-5000™ has an integrated heater for temperature ramp chromatography – ramping the temperature reduces the analysis time and aids in the separation of late eluting compounds. These components combined with an internal PID identify VOCs in ambient air at concentrations as low as 1 part per billion.
Continuous analysis:
Continuous analysis of aerosols on filters for optical and thermal analysis
OC/EC determination:
Real time/online TC/BC/EC/OC and Brc analysis in combination with our Aethalometer AE33
Ease of Use:
No fragile glassware, no catalyst, no gas supplies needed
Rugged, Reliable, automatic:
35 years of published performance, rugged, all-steel construction, unattended operation – 1 month minimum
At the core of our technology are our next‑generation air quality monitors - the Clarity Node and Node-S. These nimble monitors are configured on our web-based deployment tool and installed in a matter of minutes. Hundreds to thousands of devices work together to form a scalable network of high density air quality measurement points.
At the core of our technology are our next‑generation air quality monitors - the Clarity Node and Node-S. These nimble monitors are configured on our web-based deployment tool and installed in a matter of minutes. Hundreds to thousands of devices work together to form a scalable network of high density air quality measurement points.
At the core of our technology are our next‑generation air quality monitors - the Clarity Node and Node-S. These nimble monitors are configured on our web-based deployment tool and installed in a matter of minutes. Hundreds to thousands of devices work together to form a scalable network of high density air quality measurement points.
At the core of our technology are our next‑generation air quality monitors - the Clarity Node and Node-S. These nimble monitors are configured on our web-based deployment tool and installed in a matter of minutes. Hundreds to thousands of devices work together to form a scalable network of high density air quality measurement points.
THE GAS CHROMATOGRAPHIC REVOLUTION
FOR ENVIRONMENTAL MONITORING
PyxisGC BTEX is the first and unique gaschromatograph "carrier gas free" for remote BTEX monitoring
in ambient air. PyxisGC BTEX is manufactured by Pollution Analytical Equipment in compliance with
EN14662-3:2015.
"BTEX ambient air analysis: sources, regulations, technologies for controls"European Tech Serv
"BTEX ambient air analysis: sources, regulations, technologies for
controls"
In collaboration with The Council for Research and Experimentation in Agriculture at the Puglia
Regional Environmental Protection Agency (ARPA)
The M1000 operates according to the diffusion principle. The monitor is mounted on a flange which is located at the top of the silo or bin. The gas in the atmosphere of the silo diffuses into the oxygen sensor. Since there is no positive movement of chemical powder to the sensor the sampling gas will not block filters and tubing. The right design and choice of components ensures a long term maintenance free operation.
H2scan’s HY-ALERTA™ 600 Fixed Area Hydrogen Monitor will provide hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit
H2scan’s HY-ALERTA™ 600 Fixed Area Hydrogen Monitor will provide hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit
H2scan’s HY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit.
H2scan’s HY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit.
H2scan’s HY-ALERTA™ 2600 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s lower flammability limit.
Technology background HY-ALERTA SAFETY SYSTEMS – HY-ALERTA 2600European Tech Serv
H2scan’s HY-ALERTA™ 2600 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s lower flammability limit.
Vaccine management system project report documentation..pdfKamal Acharya
The Division of Vaccine and Immunization is facing increasing difficulty monitoring vaccines and other commodities distribution once they have been distributed from the national stores. With the introduction of new vaccines, more challenges have been anticipated with this additions posing serious threat to the already over strained vaccine supply chain system in Kenya.
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdffxintegritypublishin
Advancements in technology unveil a myriad of electrical and electronic breakthroughs geared towards efficiently harnessing limited resources to meet human energy demands. The optimization of hybrid solar PV panels and pumped hydro energy supply systems plays a pivotal role in utilizing natural resources effectively. This initiative not only benefits humanity but also fosters environmental sustainability. The study investigated the design optimization of these hybrid systems, focusing on understanding solar radiation patterns, identifying geographical influences on solar radiation, formulating a mathematical model for system optimization, and determining the optimal configuration of PV panels and pumped hydro storage. Through a comparative analysis approach and eight weeks of data collection, the study addressed key research questions related to solar radiation patterns and optimal system design. The findings highlighted regions with heightened solar radiation levels, showcasing substantial potential for power generation and emphasizing the system's efficiency. Optimizing system design significantly boosted power generation, promoted renewable energy utilization, and enhanced energy storage capacity. The study underscored the benefits of optimizing hybrid solar PV panels and pumped hydro energy supply systems for sustainable energy usage. Optimizing the design of solar PV panels and pumped hydro energy supply systems as examined across diverse climatic conditions in a developing country, not only enhances power generation but also improves the integration of renewable energy sources and boosts energy storage capacities, particularly beneficial for less economically prosperous regions. Additionally, the study provides valuable insights for advancing energy research in economically viable areas. Recommendations included conducting site-specific assessments, utilizing advanced modeling tools, implementing regular maintenance protocols, and enhancing communication among system components.
Event Management System Vb Net Project Report.pdfKamal Acharya
In present era, the scopes of information technology growing with a very fast .We do not see any are untouched from this industry. The scope of information technology has become wider includes: Business and industry. Household Business, Communication, Education, Entertainment, Science, Medicine, Engineering, Distance Learning, Weather Forecasting. Carrier Searching and so on.
My project named “Event Management System” is software that store and maintained all events coordinated in college. It also helpful to print related reports. My project will help to record the events coordinated by faculties with their Name, Event subject, date & details in an efficient & effective ways.
In my system we have to make a system by which a user can record all events coordinated by a particular faculty. In our proposed system some more featured are added which differs it from the existing system such as security.
Final project report on grocery store management system..pdfKamal Acharya
In today’s fast-changing business environment, it’s extremely important to be able to respond to client needs in the most effective and timely manner. If your customers wish to see your business online and have instant access to your products or services.
Online Grocery Store is an e-commerce website, which retails various grocery products. This project allows viewing various products available enables registered users to purchase desired products instantly using Paytm, UPI payment processor (Instant Pay) and also can place order by using Cash on Delivery (Pay Later) option. This project provides an easy access to Administrators and Managers to view orders placed using Pay Later and Instant Pay options.
In order to develop an e-commerce website, a number of Technologies must be studied and understood. These include multi-tiered architecture, server and client-side scripting techniques, implementation technologies, programming language (such as PHP, HTML, CSS, JavaScript) and MySQL relational databases. This is a project with the objective to develop a basic website where a consumer is provided with a shopping cart website and also to know about the technologies used to develop such a website.
This document will discuss each of the underlying technologies to create and implement an e- commerce website.
Student information management system project report ii.pdfKamal Acharya
Our project explains about the student management. This project mainly explains the various actions related to student details. This project shows some ease in adding, editing and deleting the student details. It also provides a less time consuming process for viewing, adding, editing and deleting the marks of the students.
About
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Technical Specifications
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
Key Features
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface
• Compatible with MAFI CCR system
• Copatiable with IDM8000 CCR
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
Application
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.
(C) 2024 Robbie E. Sayers
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)MdTanvirMahtab2
This presentation is about the working procedure of Shahjalal Fertilizer Company Limited (SFCL). A Govt. owned Company of Bangladesh Chemical Industries Corporation under Ministry of Industries.
Water scarcity is the lack of fresh water resources to meet the standard water demand. There are two type of water scarcity. One is physical. The other is economic water scarcity.
Forklift Classes Overview by Intella PartsIntella Parts
Discover the different forklift classes and their specific applications. Learn how to choose the right forklift for your needs to ensure safety, efficiency, and compliance in your operations.
For more technical information, visit our website https://intellaparts.com
Courier management system project report.pdfKamal Acharya
It is now-a-days very important for the people to send or receive articles like imported furniture, electronic items, gifts, business goods and the like. People depend vastly on different transport systems which mostly use the manual way of receiving and delivering the articles. There is no way to track the articles till they are received and there is no way to let the customer know what happened in transit, once he booked some articles. In such a situation, we need a system which completely computerizes the cargo activities including time to time tracking of the articles sent. This need is fulfilled by Courier Management System software which is online software for the cargo management people that enables them to receive the goods from a source and send them to a required destination and track their status from time to time.
1. BENEFITS
The Serinus®
range of analysers have been designed using our
experience and knowledge gained from operating large air quality
monitoring networks for more than 40 years. The result, instruments
that integrate seamlessly into continuous monitoring networks.
• Reliable performance complemented with a two year warranty
• Minimise time spent on site performing maintenance through
superior remote instrument control, diagnostic viewing and
calibration
• Comprehensive data logging and remote viewing of over 200
operational parameters
• Versatile interfacing through RS232, USB, Bluetooth, analog and
digital I/O and optional TCP/IP
• Easy setup through an intuitive menu system, advanced GUI and a
large alphanumeric keypad with tactile keys
• Instant status indication via illuminated instrument status light
buttons on the front panel
• Removable flash memory stores ~10 years of data, including up to
12 individual parameters and event logs. Operational parameters
can also be transferred to memory for easy retrieval
• Latest firmware updates can easily be installed using the USB
flash memory drive
• Programming, viewing, downloading and emailing of data is
made even simpler using Bluetooth connectivity combined with
the “ECOTECH Serinus Remote” Android App
• Built-in digital display measuring values and having function of
measuring values transferred to graphical trend display
• Enhanced operator safety through the use of 12 VDC internal
voltages
• Reduced cost of spare parts, accessories and consumable items
through extensive use of standard components across the Serinus®
range
• Rack slide design makes accessing internal components and
removing the analyser from a rack cabinet easy
• AQMS power usage can be reduced due to the instrument’s low
power demand and its ability to operate over a wide temperature
range.
Serinus®
40
OXIDES OF NITROGEN ANALYSER
The Serinus®
40 Oxides of Nitrogen (NOx
)
analyser delivers precise and reliable
performance at excellent value. It uses
proven chemiluminescence technology to
measure NO, NO2
and NOx
in ambient air
(LDL < 0.4 ppb, range 0 to 20 ppm).
APPROVALS
• US EPA approval (RFNA–0809–186)
• EN approval TÜV (936/21221977/A)
• EN approval MCERTS (MC100167/06)
• Australian Standard (AS 3580.5.1-2011)
• Russian approval (56263-14)
• French approval LSCQA