1. Data Sheet • Fieldbus-Components
P r o f i b u s PA a n d P r o f i b u s D P c o n n e c t o r s
In aluminium and stainless steel housing
With overvoltage protection
With spur line fusing
Ex-certified version
Accessories
NEW
T h e F B C o n f i e l d b u s c o n n e c t o r s a re
available in industrial design with overv o l t a g e p ro t e c t i o n f o r t h e t r u n k l i n e a n d
fusing for individual spur lines.
T h e y a re d e s i g n e d t o c o u p l e 1 - 8
measuring devices or sensors. The
connection is made via spur lines. The
spur line can be optionally connected
u s i n g a n M 1 2 c o n n e c t o r o r d i re c t l y v i a
an EMC cable gland.
• Te n s i o n c l a m p c o n n e c t i o n t e c h n o l o g y
• O v e r v o l t a g e p ro t e c t i o n
• Fusing for the individual spur lines
• EMC cable glands
• M 12 connectors
• External earth connection
•
•
•
•
•
•
United Kingdom
Weidmuller Ltd.
1 Abbey Wood Road, Kings Hill
West Malling, Kent ME19 4YT
Phone +44 1732-877032
Fax
+44 1732-873873
info@weidmuller.co.uk
http://www.weidmueller.com
USA
Other countries
W-Interconnections, Inc.
821 Southlake Boulevard
Richmond, VA 23236
Phone +1 804-7942877
Fax
+1 804-3792593
info@weidmuller.com
http://www.weidmuller.com
Weidmüller Interface GmbH & Co. KG
Postfach 3030
32720 Detmold
Phone +49 5231-14-0
Fax
+49 5231-14-2083
info@weidmueller.com
http://www.weidmueller.com
Uninterrupted bus operation
Industrial design
Integrated bus termination (non EX)
EX version
AT E X
P re s s u re c o m p e n s a t i o n e l e m e n t
Ty p e s i n s t a i n l e s s s t e e l h o u s i n g
T
3. Profibus-DP
Profibus-PA
Profibus-DP Bus Connection
24 V power supply
Profibus-PA
(EN 50 170, IEC 1158-2, DIN 19 245).
Profibus-DP Distribution
Profibus-PA is an open fieldbus standard.
It was established to meet the requirements of process engineering, which
include remote powering and intrinsic
safety.
Profibus has a line topology. The fieldbus
connectors serve to connect the individual
field devices and Remote I/O s with the
bus line (trunk line). The length of the spur
line depends on the transmission speed,
and should be kept as short as possible.
For transmission speeds up to 1.5
MBaud, the maximum total length of all
spur lines must not exceed 6.6 meters.
The trunkline is fed in to an aluminium
enclosure via EMC cable glands and
connected by means of tension clamp
terminals. The spur line to the device is
connected via a B-coded M 12 connector.
The 24 V power supply is fed in through
the cable gland provided on the righthand side for connection.
Fieldbus connectors are included with
pressure compensation elements to
counteract cyclic climatic changes.
Profibus User Organization guidelines are
to be observed.
Surface
Profibus-DP connection
Cable entry
Clamping range of cable gland
Surface of contact
Transmission rate
Supply voltage
Bus termination
• Low wiring costs
• Process control system requires only a
minimum of planning costs
• Remote inquiry and programming of
field devices
• Intrinsically safe variant for applications
in hazardous areas.
• PROFIBUS User Group offers further
developments and support.
Weidmüller supplies PROFIBUS-PA
T-connectors.
They allow field devices to be connected
or replaced during servicing or system
modifications without any interrupt in the
bus system.
A segment coupler is used for integration
into PROFIBUS-DP networks.
–25 to 55 °C
IP 66
high-grade aluminium
alloy (AL – SI 12)
Painted RAL 7001
Tension clamp terminal
0.5 - 1.5 mm2
Operating temperature
Protection class
Enclosure material
Cable gland M16
5.5 – 9.5 mm
M12 plug/socket CuZnAu
Max. 1.5 MBaud
Cable entry
Terminal range
Measuring instrument connection
Contact MS, surface
Stainless steel enclosures
Technical data
Surface
Profibus-PA connection
-40 to 85 °C
IP 66
High-grade aluminium
alloy (AL - Si 12)
Painted RAL 7001
Tension clamp
connection
0.5 - 1.5 mm2
Cable gland M16
5.5 - 9.5 mm
M12x1, 4 pole
CuZnAu
Operating temperature
Protection class
Material, enclosure
Profibus-PA connection
Cable entry
Terminal range
Measuring instrument connection
Contact MS, surface
-40 to 85 °C
IP 66
Stainless steel 316 (L)
1.4404
Tension clamp
connection
0.5 - 1.5 mm2
Cable gland M16
5.5 - 9.5 mm
M12x1, 4 pole
CuZnAu
24Vdc +/- 10%
Processing notes
Processing notes
Processing notes
Torques:
M16 cable glands on enclosure
Union nut, M 16 cable gland
Enclosure lid
Earth connection, external
Adapter/spur line
32 devices can be operated in one segment. Using repeaters allows the maximum number of stations to be increased
126, and the maximum end-to-end
distance of the bus extended to 10 km.
At a data transmission rate of 31.25
kbps, the length of the bus without
repeaters can reach 1,900 m, in hazardous areas up to 1,000 m. The bus
topology is star, tree or line.
Aluminium enclosures
Technical data
Profibus-DP
Technical data
Operating temperature
Protection class
Enclosure material
PROFIBUS-PA allows several sensors
and actuators to be operated via one bus
cable. The devices are supplied with
power over a 2-wire architecture; process
data is communicated digitally.
Specific Advantages:
6.0 Nm
4.0 Nm
1.8 – 2.0 N
1.8 – 2.0 Nm
Finger-tight
Torques:
M16 cable glands on enclosure
Union nut, M 16 cable glands
Enclosure lid
Earth connection, external
Adapter/spur line
6.25 Nm
4.5 Nm
1.8 - 2.0 Nm
1.8 - 2.0 Nm
Finger-tight
Torques:
M16 cable glands on enclosure
Union nut, M 16 cable glands
Enclosure lid
Earth connection, external
~ 5 Nm
~ 3.75 Nm
1.8 - 2.0 Nm
1.8 - 2.0 Nm
3
4. Profibus for the Ex-Area
EX AREA – EX AREA – EX AREA – EX AREA – EX AREA – EX AREA – EX ARE
A new concept for explosion protection in Europe
The difference with ATEX
The so-called ATEX directive (from the French “atmosphères
explosives”), official number 94/9/EC, was defined in law in
1996 in the member states of CENELEC. Behind the concept
of the new directive was the intention of simplifying the previous
system where changes in the laws in the member states were
regulated by national and international standards. The law was
passed under article 95 of the Treaty of Rome (foundation of the
European Union). The directive ATEX 95 resulted from this law.
In comparison to the “old concept”, the mechanical components
and systems are to be taken into account with ATEX.
This also relates to mining.
The existing definition of the term “area subject to explosion
hazards” remains unaffected. This refers to inflammable substances and materials that could deflagrate with air under atmospheric conditions.
First standards such as the EN50014 series for hazard areas
were adopted in the EC directive. As national legal requirements
are based on this directive, even minor changes require a standards change in the related directive as well as in national law.
The ATEX directive is not based on a single standard, but specifies a series of essential health and safety requirements. The
EN50014 series of ‘harmonised standards’ support the ATEX
directive, but no longer stipulates their content. This is termed a
‘new concept’.
Ventilation Duct
Objective of the directive
ATEX 95 is concerned with the continual introduction and commissioning of all products on the market. Primarily, the issue is
the free exchange of goods across national borders within the
EU and the member states of CENELEC.
All products that are in operation since 01.07.2003
must meet the requirements of the directive.
Flammable Liquid
Flammable Liquid Storage Vessel
T
4
6. Profibus PA fieldbus connectors FB Con
Technical data Profibus PA connector
Operating temperature
Type of protection
Material of housing
Surface
PROFIBUS-PA - Connection
Cable bushing
Clamping area
Connector M12 x 1 4-pole
from -40 to 85°C
IP 66
high-quality aluminium alloy (AL - Si 12)
powder coated RAL 7001
tension clamp connection 0.5 - 1.5 mm2
cable gland M16
5.5 - 9.6 mm
contacts brass, surface CUZnAu
Technical data Profibus PA connector with overvoltage protection
Nominal voltage DCV/AC
Max. operating voltage
Nominal current with 25°C
Un = 24 V DC / 18 V AC
Uc = 30 V DC / 21 V AC
In = 500 mA
Limited output voltage (wire-wire/ wire-PE)
Rated discharge current
Output voltage max.
Resistor per line
<65 V/< 600 V
Isn = 5 kA (wire-wire/wire-PE)
Up = 65 V
2,2 Ohm
Technical data Profibus PA connector with fuse
Nominal voltage DCV/AC
Max. operating voltage
Un = 24 V DC / 18 V AC
Uc = 30 V DC / 21 V AC
Nominal current with 25°C
Short circuit, spur
Max. hold current
Max. tripping current
In = 500 mA
100 mA Polyfuse
Ihold = 100 mA, 20 °C
Itrip = 200 mA, 20 °C
Installation advice
M16 cable gland on housing
Coupling ring M16 cable gland
Housing lid
External earthing cable
6.0 Nm
4.0 Nm
1.8 - 2.0 Nm
1.8 - 2.0 Nm
Ordering data
Type
Profibus PA T connector FBCon PA CG/M12 1way
Profibus PA T connector FBCon PA CG/M12 2way
Profibus PA T connector FBCon PA CG/M12 4way
Profibus PA T connector FBCon PA CG/M12 8way
Part No.
8564060000
8564070000
8564080000
8564310000
Profibus PA T connector FBCon PA CG 1way
Profibus PA T connector FBCon PA CG 2way
Profibus PA T connector FBCon PA CG 4way
Profibus PA T connector FBCon PA CG 8way
8564090000
8564100000
8564110000
8564300000
Profibus PA T connector FBCon PA CG/M12 1way Fuse
Profibus PA T connector FBCon PA CG/M12 2way Fuse
Profibus PA T connector FBCon PA CG/M12 4way Fuse
Profibus PA T connector FBCon PA CG/M12 8way Fuse
Profibus PA T connector FBCon PA CG 1way Fuse
Profibus PA T connector FBCon PA CG 2way Fuse
Profibus PA T connector FBCon PA CG 4way Fuse
Profibus PA T connector FBCon PA CG 8way Fuse
871416 0000
871417 0000
871418 0000
871419 0000
871420 0000
871421 0000
871422 0000
871423 0000
Profibus PA T connector FBCon PA CG/M12 1way OVP
Profibus PA T connector FBCon PA CG/M12 2way OVP
Profibus PA T connector FBCon PA CG/M12 4way OVP
Profibus PA T connector FBCon PA CG/M12 8way OVP
Profibus PA T connector FBCon PA CG 1way OVP
Profibus PA T connector FBCon PA CG 2way OVP
Profibus PA T connector FBCon PA CG 4way OVP
Profibus PA T connector FBCon PA CG 8way OVP
871408 0000
871409 0000
871410 0000
871411 0000
871412 0000
871413 0000
871414 0000
871415 0000
Shield is connected to the enclosure via the EMC cable glands.
Thread the cable gland onto the seal, on the unprepared
fieldbus cable
Strip fieldbus cable here
Fieldbus cable
Shielding
8
Draw back the shielding braid
over the sheath of the fieldbus cable
6
6
50 … 70
Use ferrules!
7. Profibus PA fieldbus connectors FB Con in aluminium housing
• Trunkline with EMC cable gland connection
• Spur lines with M12 connectors
PROFIBUS-PA T-Connector standard 1-way / Type FBCon PA CG/M12 1way
Circuit diagram
A
S
58
19
A
S
B
A
S
B
A
S
R1
off
A
S
B
B
B
Bus terminator
C1
on
100R
Bus terminator:
64
off
off on
Wire bridge
C1
1uF 50Vdc
on
A
S
B
n.c.
Ordering data
A
Type
Profibus PA T connector FBCon PA CG/M12 1way
Part No.
8564060000
R1
S
B
n.c.
PA(3)
Shielding (4)
PA+
(1)
(2)
PROFIBUS-PA T-Connector standard 2-way / Type FBCon PA CG/M12 2way
Circuit diagram
A
S
B
A
S
B
A
S
B
A
S
B
S
B
64
A
A
S
19
B
C1
off
Bus terminator
on
100R
R1
off
on
R1
Wire bridge
Bus terminator:
C1
1uF 50Vdc
98
off
on
A
S
B
n.c.
Ordering data
A
Type
Profibus PA T connector FBCon PA CG/M12 2way
Part No.
8564070000
A
S
B
n.c.
S
B
n.c.
PA(3)
Shielding (4)
PA+
(1)
(2)
PROFIBUS-PA T-Connector standard 4-way / Type FBCon PA CG/M12 4way
Circuit diagram
A
S
B
A
S
B
A
S
B
A
A
S
B
A
S
B
B
A
S
B
Bus terminator
S
S
A
A
B
B
S
S
off
S
B
B
80
19
A
S
B
A
A
100R
on
R1
1uF
63V
C1
Bus terminator:
125
off
Wire
bridge
on
A
Ordering data
n.c.
Type
Profibus PA T connector FBCon PA CG/M12 4way
A
S
B
n.c.
S
A
B
S
A
B
n.c.
A
S
B
n.c.
S
B
n.c.
Part No.
8564080000
PA(3)
Shielding (4)
PA+
(1)
(2)
PROFIBUS-PA T-Connector standard 8-way / Type FBCon PA CG/M12 8way
Circuit diagram
S
B
A
80
A
S
off
A
S
A
S
B
A
S
B
A
S
B
A
S
B
on
B
S
A
B
S
A
S
A
B
B
S
A
B
S
A
B
S
A
A
S
B
Bus terminator
B
S
A
S
B
B
B
S
A
A
S
B
A
B
B
S
A
B
R1
100R
S
A
Bus terminator:
Wire
bridge
3
1
A S
off
Ordering data
175
Type
Profibus PA T connector FBCon PA CG/M12 8way
on
Part No.
8564310000
A S
B
2
A S
5
A S
B
A S
A S
B
6
4
B
B
1…8
A S
C1
1uF63V
8
A
S
B
B
8
B
A
A
n.c.
S
PAShielding
PA+
B
S
B
seen in the
direction of
the socket
7
8. Profibus PA fieldbus connectors FB Con in aluminium housing
• Trunkline and all spur lines with EMC cable gland connection
PROFIBUS-PA T-Connector EMC version 1-way / Type FBCon PA CG 1way
Circuit diagram
A
S
58
19
A
S
B
A
S
B
A
S
R1
off
B
A
S
B
B
C1
on
Bus terminator
100R
off
64
Wire bridge
C1
1uF 50Vdc
on
Ordering data
A
S
B
n.c.
A S B
Type
Profibus PA T connector FBCon PA CG 1way
R1
off on
Bus terminator:
Part No.
8564090000
PA(3)
Shielding (4)
PA+
(1)
(2)
PROFIBUS-PA T-Connector EMC version 2-way / Type FBCon PA CG 2way
Circuit diagram
A
S
B
A
S
B
A
S
B
A
S
B
64
A
C1
off
A
S
19
S
B
on
B
R1
Bus terminator
100R
off
on
R1
Wire bridge
Bus terminator:
C1
1uF 50Vdc
98
off
on
A
Ordering data
Type
Profibus PA T connector FBCon PA CG 2way
S
B
A
S
A
S
B
n.c.
B
Part No.
8564100000
PA(3)
Shielding (4)
PA+
(1)
(2)
PROFIBUS-PA T-Connector EMC version 4-way / Type FBCon PA CG 4way
Circuit diagram
A
S
B
A
S
B
A
S
B
A
S
B
A
S
B
A
S
A
S
B
B
80
19
off
A
S
B
Bus terminator
100R
on
R1
1uF
63V
C1
Wire
bridge
Bus terminator:
A S B
off
125
on
A
S
B
n.c.
Ordering data
Type
Profibus PA T connector FBCon PA CG 4way
A S B
Part No.
8564110000
A S B
A S B
PA(3)
Shielding (4)
PA+
(1)
(2)
PROFIBUS-PA T-Connector EMC version 8-way / Type FBCon PA CG 8way
Circuit diagram
A
B
S
80
A
off
A
S
A
A
B
S
S
A
B
B
S
A
B
on
B
S
A
B
S
A
S
A
B
B
S
A
B
S
A
B
S
A
A
B
S
B
S
R1
100R
A
off
on
C1
1uF63V
Wire
bridge
3
1
A S
B
A S
5
B
A S
8
B
A S
B
175
Type
Profibus PA T connector FBCon PA CG 8way
8
B
Bus terminator
S
Bus terminator:
Ordering data
S
B
B
S
A
A
A
S
B
S
A
B
B
S
A
B
S
Part No.
8564300000
A S
B
A S
B
A S
B
A S
B
A
S
B
PAShielding
PA+
9. Profibus PA fieldbus connectors FB Con in aluminium housing, with fuse
• Trunkline with EMC cable gland connection
• All spur lines with M12 connectors and 100 mA self refreshing fuses
PROFIBUS-PA T-Connector standard 1-way / Type FBCon PA CG/M12 1way Fuse
Circuit diagram
x1
x3
A1
19
1A
A
S
B
A
S
B
A
S
R1
off
2S
B3
58
S2
3B
B
C1
on
R1
Bus terminator:
1
1
2
3
64
off
2
x8
3
100R
C1
1uF
63V
on
Ordering data
Type
Profibus PA T connector FBCon PA CG/M12 1way Fuse
Part No.
8714160000
x2
1
A
2
S
A
S
B
3
B
PAShielding
PA+
A → PA(3)
S → Shielding (4)
B → PA+
(1)
(3)
(4)
(1)
PROFIBUS-PA T-Connector standard 2-way / Type FBCon PA CG/M12 2way Fuse
Circuit diagram
A1
x1
x3
1A
19
S
B
A
S
B
S
B
A
S
S2
B
2S
B3
A
3B
64
A
C1
off
on
R1
Bus terminator:
98
off
1 2 3
x10
C1
1uF 63V
1
2
3
on
F1
R1
100R
F2
Ordering data
Type
Profibus PA T connector FBCon PA CG/M12 2way Fuse
x2
Part No.
8714170000
1
A
2
S
x3
3
B
1
A
2
S
3
B
A
S
PA(3)
Shielding (4)
A → PA(3)
S → Shielding (4)
B → PA+
(1)
PROFIBUS-PA T-Connector standard 4-way / Type FBCon PA CG/M12 4way Fuse
Circuit diagram
A
S
B
A
S
B
A
S
B
A
A
S
B
A
S
B
B
x6
1A
2S
3B
S
S
A
A
B
B
S
S
off
S
B
B
80
19
x1
A1
S2
B3
100R
1 2 3 R1
C1
x7
1uF 63V
A
A
on
R1
1
2
3
C1
Bus terminator:
125
off
F
2
F
3
F
4
x5
x2
x3
x4
1 2 3
1 2 3
1 2 3
1 2 3
A S B A S B
A S B
A S B
on
Ordering data
Type
Profibus PA T connector FBCon PA CG/M12 4way Fuse
F
1
A
S
B
Part No.
8714180000
A
PA- → PA- (3) (3)
Shielding
(4)
S → Shielding (4)
PA+ → PA+ (1) (1)
B
PROFIBUS-PA T-Connector standard 8-way / Type FBCon PA CG/M12 8way Fuse
Circuit diagram
A
B
S
80
A
off
A
S
A
A
B
S
S
A
B
B
S
A
B
on
B
S
A
B
S
A
A1
S2
B3
B
S
A
B
B
S
A
B
S
S
A
B
B
S
A
B
S
A
B
S
A
B
S
A
B
S
B
S
A
S
A
Bus terminator:
off
Ordering data
175
Type
Profibus PA T connector FBCon PA CG/M12 8way Fuse
1A
2S
3B
Part No.
8714190000
on
1
2
3
F
1
F
2
F
5
C1
1uF 63V
R1
100R
F
7
123
off on
1 2 3
A S B
F
2
1 2 3
A S B
1 2 3
A S B
F
4
1 2 3
A S B
1 2 3
A S B
F
6
1 2 3
A S B
1 2 3
A S B
F
8
1 2 3
A S B
A → PA(3)
S → Shielding (4)
B → PA+
(1)
9
10. Profibus PA fieldbus connectors FB Con in aluminium housing, with fuse
• Trunkline and spur lines with EMC cable gland connection
• All spur lines with 100 mA self refreshing fuses
PROFIBUS-PA T-Connector EMC version 1-way / Type FBCon PA CG 1way Fuse
Circuit diagram
x1
x3
A1
58
19
A
S
B
A
S
B
A
S
R1
off
1A
S2
C1
on
2S
B3
B
3B
R1
Bus terminator:
1
1
2
3
off
64
2
x8
3
100R
C1
1uF
63V
on
Ordering data
Type
Profibus PA T connector FBCon PA CG 1way Fuse
x2
Part No.
8714200000
1
A
2
S
A
S
B
3
B
PAShielding
PA+
A → PA(3)
S → Shielding (4)
B → PA+
(1)
(3)
(4)
(1)
PROFIBUS-PA T-Connector EMC version 2-way / Type FBCon PA CG 2way Fuse
Circuit diagram
19
S
B
A
S
B
A
S
B
A
S
A1
B
64
A
x1
x3
1A
S2
2S
B3
C1
off
3B
on
R1
1 2 3
x10
C1
1uF 63V
Bus terminator:
1
2
3
98
off
on
F1
R1
100R
F2
Ordering data
Type
Profibus PA T connector FBCon PA CG 2way Fuse
x2
Part No.
8714210000
1
A
2
S
x3
3
B
1
A
2
S
3
B
A
A → PA(3)
S → Shielding (4)
B → PA+
(1)
PA
(3)
PROFIBUS-PA T-Connector EMC version 4-way / Type FBCon PA CG 4way Fuse
Circuit diagram
A
S
B
A
S
B
A
S
B
A
S
B
A
S
B
A
S
x1
A1
S2
B3
B
80
19
off
x6
1A
2S
3B
on
R1
100R
1 2 3 R1
C1
x7
1uF 63V
C1
1
2
3
Bus terminator:
off
125
F
2
F
3
F
4
x5
x2
x3
x4
1 2 3
1 2 3
1 2 3
1 2 3
A S B A S B
A S B
A S B
on
Ordering data
Type
Profibus PA T connector FBCon PA CG 4way Fuse
F
1
A
S
B
Part No.
8714220000
A
PA- → PA- (3) (3)
S → Shielding (4)
Shielding
(4)
PA+ → PA+ (1) (1)
B
PROFIBUS-PA T-Connector EMC version 8-way / Type FBCon PA CG 8way Fuse
Circuit diagram
A
B
S
80
A
A
S
A
A
B
S
S
A
B
A
B
S
B
B
S
A
B
S
A
A1
S2
B3
B
S
on
A
B
B
S
A
B
S
off
S
A
B
B
S
A
B
S
A
B
S
A
S
A
B
S
B
B
S
A
off
175
Type
Profibus PA T connector FBCon PA CG 8way Fuse
10
C1
1uF 63V
R1
100R
S
A
Bus terminator:
Ordering data
1A
2S
3B
Part No.
8714230000
on
1
2
3
F
1
F
2
F
5
F
7
123
off on
1 2 3
A S B
F
2
1 2 3
A S B
1 2 3
A S B
F
4
1 2 3
A S B
1 2 3
A S B
F
6
1 2 3
A S B
1 2 3
A S B
F
8
1 2 3
A S B
A → PA(3)
S → Shielding (4)
B → PA+
(1)
11. Profibus PA fieldbus connectors FB Con in aluminium housing, with OVP
• Trunkline with over voltage protection (OVP) and EMC cable gland connection
• Spur lines with M12 connector
PROFIBUS-PA T-Connector standard1-way / Type FBCon PA CG/M12 1way OVP
Circuit diagram
x3
x1
A1
58
A
S
B
A
S
B
A
S
B3
B
1A
2S
S2
19
3B
1
Bus terminator:
2
1
R2
2
C1
1uF 63V
R4 3
R5
R6
R1
100R
64
off
1 2 3
x8
V3
on
Ordering data
Type
Profibus PA T connector FBCon PA CG/M12 1way OVP
x2
Part No.
8714080000
A
S
B
x4
1
A
2
S
3
B
PAShielding
PA+
A → PA(3)
S → Shielding (4)
B → PA+
(1)
(3)
(4)
(1)
PROFIBUS-PA T-Connector standard 2-way / Type FBCon PA CG/M12 2way OVP
Circuit diagram
x1
x4
A1
19
S
B
A
S
B
A
S
B
A
S
1A
2S
S2
B
64
A
B3
1
1
R3
3B
R2
C1
1uF
63V
2
3
2
Bus terminator:
R4
R1
100R
R5
V1
98
off
1 2 3
x10
on
Ordering data
Type
Profibus PA T connector FBCon PA CG/M12 2way OVP
x2
Part No.
8714090000
x3
1
A
2
S
3
B
1
A
2
S
3
B A
S
A → PA(3)
S → Shielding (4)
(1)
(3) B → PA+
PAShielding
(4)
PROFIBUS-PA T-Connector standard 4-way / Type FBCon PA CG/M12 4way OVP
Circuit diagram
x1
A1
A
S
B
A
S
B
A
S
B
A
S
A
S
A
S
1A
2S
B3
S
1
R2
A
A
x6
S2
B
B
S
A
B
B
S
S
A
B
B
B
80
19
2
R4
Bus terminator:
125
off
3B
1 R3
2
3
R1
R5
1 2 3
x7
C1
100R 1uF 63V
V3
on
Ordering data
Type
Profibus PA T connector FBCon PA CG/M12 4way OVP
x2
1 2
A S
Part No.
8714100000
x3
3
1 2
B
A S
x4
3
1 2
B
A S
x5
1 2
3
A S
B
3
B
A → PA(3)
S → Shielding (4)
B → PA+
(1)
PROFIBUS-PA T-Connector standard 8-way / Type FBCon PA CG/M12 8way OVP
Circuit diagram
S
B
A
S
B
A
S
B
A
S
B
A
S
B
A
S
x1
A1
B
80
A
A
S
A
B
B
B
S
A
B
S
A
B
S
A
S
A
B
B
S
A
B
S
A
B
S
A
1A
2S
B
S
A
x6
S2
B
B
S
A
S
B3
S
1
R2
A
1
2
3
R4
Bus terminator:
off
Ordering data
175
Type
Profibus PA T connector FBCon PA CG/M12 8way OVP
Part No.
8714110000
on
3B
R3
2
R1
R5
C1
1 2 3 100R 1uF 63V
x7
V3
x5
x3
x2
x4
1 2 3
1 2 3
1 2 3
1 2 3
A S B
A S B
A S B
A S B
x8
1 2 3
A S B
x
28
x
27
1 2 3
A S B
1 2 3
A S B
x
29
1 2 3
A S B
A →
PAS →Shielding
B →
PA+
(3)
(4)
(1)
11
12. Profibus PA fieldbus connectors FB Con in aluminium housing, with OVP
• Trunkline with over voltage protection (OVP)
• Trunkline and spur lines with emc cable gland connection
PROFIBUS-PA T-Connector standard 1-way / Type FBCon PA CG 1way OVP
Circuit diagram
A1
19
x3
x1
1A
2S
58
S2
A
S
B
A
S
B
A
S
B
B3
3B
1
Bus terminator:
2
1
R2
2
C1
1uF 63V
R4 3
R5
R6
R1
100R
1 2 3
x8
V3
off
64
on
Ordering data
Type
Profibus PA T connector FBCon PA CG 1way OVP
x2
Part No.
8714120000
A
S
B
x4
1
A
2
S
3
B
PAShielding
PA+
A → PA(3)
S → Shielding (4)
B → PA+
(1)
(3)
(4)
(1)
PROFIBUS-PA T-Connector standard 2-way / Type FBCon PA CG 2way OVP
Circuit diagram
x1
x4
A1
1A
S2
2S
19
S
B
A
S
B
A
S
B
A
S
B
64
A
B3
1
on
3B
R2
1
R3
C1
1uF
63V
2
3
2
Bus terminator:
R4
R1
100R
R5
V1
98
off
1 2 3
x10
on
A → PA(3)
S → Shielding (4)
B → PA+
(1)
Ordering data
Type
Profibus PA T connector FBCon PA CG 2way OVP
x2
Part No.
8714130000
x3
1
A
2
S
3
B
1
A
2
S
3
B A
S
PAShielding
(3)
(4)
PROFIBUS-PA T-Connector standard 4-way / Type FBCon PA CG 4way OVP
Circuit diagram
A
S
B
A
S
B
A
S
B
A
S
B
A
S
B
A
S
x1
A1
B
80
19
x6
1A
2S
S2
B3
1
R2
3B
1 R3
2
3
2
Bus terminator:
R4
R1
R5
1 2 3
x7
C1
100R 1uF 63V
V3
125
off
on
Ordering data
Type
Profibus PA T connector FBCon PA CG 4way OVP
x2
1 2
A S
Part No.
8714140000
3
B
x3
1 2
A S
3
B
x4
1 2
A S
3
B
x5
1 2
A S
A → PA(3)
S → Shielding (4)
B → PA+
(1)
3
B
PROFIBUS-PA T-Connector standard 8-way / Type FBCon PA CG 8way OVP
Circuit diagram
S
B
A
80
A
S
off
A
S
A
S
B
A
S
B
A
S
B
A
S
x1
A1
B
on
A
B
B
B
S
A
B
B
S
A
B
S
A
S
A
B
B
S
A
B
S
A
B
S
A
1A
2S
B
S
A
x6
S2
B
B
S
A
S
B3
S
1
R2
A
1
2
3
R4
Bus terminator:
Ordering data
175
Type
Profibus PA T connector FBCon PA CG 8way OVP
12
off
Part No.
8714150000
on
3B
R3
2
R1
R5
V3
C1
1 2 3 100R 1uF 63V
x7
x5
x3
x2
x4
1 2 3
1 2 3
1 2 3
1 2 3
A S B
A S B
A S B
A S B
x
x
x
28
29
27
x8
1 2 3
1 2 3
1 2 3
1 2 3
A S B
A S B
A S B
A S B
A → PA(3)
S → Shielding (4)
B → PA+
(1)
13. Profibus PA fieldbus connectors FB Con in stainless steel housing
• Trunk line and spur lines with plastic or stainless steel cable glands
Stainless steel housing 1 way
pressure compensation element
circuit diagramm
earthing screw M4
The use of a ferrule
is recommended
A
S
A
S
B
B
Bus termination
100R
A
S
B
A
B
S
A
S
B
off on
wire-bridge
R1
C1
1uF 50Vdc
A S B
A
S
B
Bus termination:
on
off
PAshield
PA+
Stainless steel housing 4 way
circuit diagramm
earthing screw M4
The use of a ferrule
is recommended
pressure
compensation
element
A
S
B
A
S
B
Bus termination
100R
S
B
A
S
B
A
S
B
A
S
B
A
S
B
A
S
wirebridge
B
80
A
A S B
A S B
A S B
on
off
A S B
A
S
B
Bus termination:
1uF
63V
PAshield
PA+
125
Stainless steel housing 8 way
circuit diagramm
pressure compensation
element
X10
X1
A
A
1
S
2
2
S
B
3
3
B
1
Bus termination
S
B
A
S
off
S
B
S
A
B
A
S
B
A
S
B
A
S
B
A
S
100R
B
on
A
B
B
B
S
A
B
S
A
S
A
B
B
S
A
B
S
A
B
S
A
B
B
S
A
S
B
S
A
80
A
A
123
S
A
wirebridge
X2
1
2
S
X4
3
A
earthing screw M4
The use of a ferrule
recommended
B
1
2
S
B
1
2
S
X8
3
A
B
1
2
3
A
S
C1
1uF 63V
B
175
X3
1
2
3
A
S
X5
B
1
2
3
A
S
B
Bus termination:
off
Ordering data
Type
X6
3
A
R1
on
X7
1
2
3
A
S
B
A
S
B
X9
1
2
3
A
S
B
PAshield
PA+
Part No.
FB Con 1way
with plastic cable glands
with stainless steel cable glands
FBCon SS P CG 1way
FBCon ST/ST CG 1way
8613670000
8703430000
FB Con 4way
with plastic cable glands
with stainless steel cable glands
FBCon SS P CG 4way
FBCon ST/ST CG 4way
8613680000
8703450000
FB Con 8way
with plastic cable glands
with stainless steel cable glands
FBCon SS P CG 8way
FBCon ST/ST CG 8way
8640720000
8703470000
13
14. Profibus PA for the Ex-Area
Profibus PA T-connector
• EEx (ia) ATEX
The PROFIBUS-PA installation products
are increasingly found in the
PROFIBUS-PA T-Connector
- EEx (ia)
• Food industries
• 1-way
• Fine and speciality chemicals
• 2-way
• Bulk chemicals industry.
• 4-way
• 8-way
The PROFIBUS-PA T-Connector
EEx (ia) is intended for the coupling of
sensors, actuators and measuring instruments in areas subject to explosion hazards.
• Approval for intrinsically safe usage
ATEX approval
• Type of protection IP 66
The range is designed to accommodate a
wide range of customer requirements in
the harshest of environments.
• Modular design
These include Standard and Hazardous
Area Versions with either single or multiple
quick-connection variants with M12 connector or cable gland.
• Easy to use
Weidmüller offers, for almost every application, a solution. In the case you don’t
see your solution here, please contact
your local sales office.
14
• Non-interrupted BUS operations, also
when being serviced
• External grounding cable
• External bus terminator
15. area EEx (ia)
FBCon Bus Terminator without earth connection
FBCon Bus Terminator with earth connection
45
45
FBCon Bus Terminator
855646 0000
T II 2 G
EEx ia IIC T6
Ui
17,5 V
Ii
380 mA
20
06
EEx m II T6
10 Ö 30 V
FBCon Bus Terminator
860618 0000
06
T II 2 G
49
20
EEx ia IIC T6
Ui
17,5 V
Ii
380 mA
EEx m II T6
10
30 V
Ta: -40 …80 °C
Ta: -40 80 ¡ C
KEMA 01 ATEX 1058 X
49
FB Con Bus Terminator for the
KEMA 01 ATEX 1058 X
0344
0344
The use of a cable shoe is
recommended for the
earthing of the bus terminator.
Ordering data
Ordering data
Type
FBCon Bus Terminator EEx with locking clip + without earth connection
FBCon Bus Terminator EEx without locking clip + without earth connection
Part No.
8556460000
8606190000
Technical data
Part No.
8606180000
8606200000
Technical data
Temperature range/operating temperature
Type of protection
Material of housing
Surface
Connecting cable
Cable bushing
- 40 to 80 ºC
IP 66
high-quality aluminium alloy (AL - Si 12)
black powder coated
2x0.14 mm2
Bus adapter M16
Installation advice
Temperature range/operating temperature
Type of protection
Material of housing
Surface
Connecting cable
Cable bushing
- 40 to 80 ºC
IP 66
high-quality aluminium alloy (AL - Si 12)
black powder coated
2x0.14 mm2
Bus adapter M16
Installation advice
Torques
M16 adapter on the housing
External earthing cable (if necessary)
Housing lid without locking clip
Type
FBCon Bus Terminator EEx with locking clip + with earth connection
FBCon Bus Terminator EEx without locking clip + with earth connection
6.0 Nm
1.8 - 2.0 Nm
Housing lid
with locking clip
Torques
M16 adapter on the housing
External earthing cable (if necessary)
6.0 Nm
1.8 - 2.0 Nm
Circuit diagram
Cable brown
Cable white
30,5
30,5
15
16. Profibus PA for the Ex-Area
Shield is connected to the enclosure via the EMC cable glands.
Thread the cable gland onto the seal, on the unprepared
fieldbus cable
Strip fieldbus cable here
Fieldbus cable
Shielding
6
8
Draw back the shielding braid
over the sheath of the fieldbus cable
50 … 70
Use ferrules!
Technical data for pages 10-11
Temperature range
Operating temperature
Type of protection
Material of housing
Surface
PROFIBUS-PA - Connection
Cable bushing
Clamping area
Connector M12 x 1 4-pole
from -40 to 60°C
IP 66
high-quality aluminium alloy (AL - Si 12)
stove-enamelled RAL 5015
tension clamp connection 0.5 - 1.5 mm2
Cable gland M16
5.5 - 9.6 mm
contacts brass, surface CUZnAu
Installation advice
Torques
M16 cable gland on housing
Coupling ring M16 cable gland
Housing lid
Adapter / stub cable
External earthing cable
6.25 Nm
4.5 Nm
1.8 - 2.0 Nm
hand-tight
1.8 - 2.0 Nm
Ordering data
Type
Profibus PA T connector FBCon PA CG/M12 1way EX
Profibus PA T connector FBCon PA CG/M12 2way EX
Profibus PA T connector FBCon PA CG/M12 4way EX
Profibus PA T connector FBCon PA CG/M12 8way EX
Part No.
8564150000
8564160000
8564170000
8564250000
Profibus PA T connector FBCon PA CG 1way EX
Profibus PA T connector FBCon PA CG 2way EX
Profibus PA T connector FBCon PA CG 4way EX
Profibus PA T connector FBCon PA CG 8way EX
8564180000
8564190000
8564200000
8564240000
With the EEx (ia) version an external bus terminator is necessary at the end of the bus system
Weidmüller offers here the PROFIBUS-PA FB-Connector. In the event of service or plant modification,
the PROFIBUS-PA FB-Connector from Weidmüller permits the connection or replacement of field devices without interrupting the bus
system. Extensive accessories as well as preassembled cables and plugs round off the program.
Customer-specific solutions on request
16
17. Profibus PA fieldbus connectors for the
area EEx (ia)
• Trunkline and all spur lines with emc cable gland connection
PROFIBUS-PA T-Connector EEx EMC version 1-way / Type FBCon PA CG 1way
Circuit diagram
58
19
A
S
B
A
S
B
A
S
A
S
B
A
S
B
B
Wire bridge
A
S
B
n.c.
64
Ordering data
Type
Profibus PA T connector FBCon PA CG 1way EX
A S B
Part No.
8564180000
PA(3)
Shielding (4)
PA+
(1)
(2)
PROFIBUS-PA T-Connector EEx EMC version 2-way / Type FBCon PA CG 2way
Circuit diagram
19
A
A
S
B
A
S
B
A
S
S
B
B
B
B
64
S
A
S
A
on
A
S
B
n.c.
Wire bridge
98
Ordering data
A
Type
Profibus PA T connector FBCon PA CG 2way EX
S
B
A
S
PA(3)
Shielding (4)
PA+
(1)
(2)
B
Part No.
8564190000
PROFIBUS-PA T-Connector EEx EMC version 4-way / Type FBCon PA CG 4way
Circuit diagram
A
S
B
A
S
B
A
S
B
A
S
B
A
S
B
A
S
B
80
19
A
S
B
A
S
B
A
S
B
n.c.
Wire
bridge
125
Ordering data
A S B
Type
Profibus PA T connector FBCon PA CG 4way EX
A S B
A S B
PA(3)
Shielding (4)
PA+
(1)
(2)
A S B
Part No.
8564200000
PROFIBUS-PA T-Connector EEx EMC version 8-way / Type FBCon PA CG 8way
Circuit diagram
S
B
A
80
A
S
off
A
S
A
S
B
A
S
B
A
S
B
A
S
B
on
B
S
A
B
S
A
S
A
B
B
S
A
B
S
A
B
S
A
A
S
B
B
S
B
S
A
A
S
B
A
S
B
B
A
B
B
S
A
B
S
A
Wire
bridge
1
A S B
Ordering data
3
A S B
5
A S B
8
A S B
175
A B S
Type
Profibus PA T connector FBCon PA CG 8way EX
Part No.
8564240000
A S B
A S B
A S B
A
S
B
PA(3)
Shielding (4)
PA+
(1)
17
18. Profibus PA fieldbus connectors for the
area EEx (ia)
• Trunkline with emc cable glands connection.
• Spur lines with M12 connector
PROFIBUS-PA T-Connector EEx 1-way / Type FBCon PA CG/M12 1way
Circuit diagram
A
S
19
A
S
B
58
B
A
S
B
A
S
B
A
S
B
A
S
B
n.c.
Wire bridge
64
Ordering data
A
Type
Profibus PA T connector FBCon PA CG/M12 1way EX
Part No.
8564150000
PA(3)
Shielding (4)
PA+
(1)
(2)
S
B
n.c.
PROFIBUS-PA T-Connector standard EEx 2-way / Type FBCon PA CG/M12 2way
Circuit diagram
A
S
B
A
S
B
A
S
B
A
S
S
B
B
64
A
A
S
19
B
A
S
B
n.c.
Wire bridge
98
PA(3)
Shielding (4)
PA+
(1)
(2)
Ordering data
A
Type
Profibus PA T connector FBCon PA CG/M12 2way EX
Part No.
8564160000
A
S
B
n.c.
S
B
n.c.
PROFIBUS-PA T-Connector EEx 4-way / Type FBCon PA CG/M12 4way
Circuit diagram
A
S
B
A
S
B
A
S
B
A
S
A
S
A
S
A
S
B
B
S
S
A
B
B
B
S
S
A
B
B
B
80
19
A
S
B
A
S
B
n.c.
A
A
Wire
bridge
PA(3)
Shielding (4)
PA+
(1)
(2)
125
A
Ordering data
Type
Profibus PA T connector FBCon PA CG/M12 4way EX
A
S
B
n.c.
S
B
n.c.
A
S
A
B
n.c.
S
B
n.c.
Part No.
8564170000
PROFIBUS-PA T-Connector EEx 8-way / Type FBCon PA CG/M12 8way
Circuit diagram
A
B
S
S
B
A
A
B
S
S
A
B
B
S
A
A
S
A
S
A
B
B
B
S
A
B
S
A
B
S
A
S
A
B
B
S
A
B
S
A
B
S
A
B
S
A
B
S
B
S
B
S
A
A
B
B
S
80
A
S
A
3
1
A S
B
2
Ordering data
175
Type
Profibus PA T connector FBCon PA CG/M12 8way EX
18
A S
Part No.
8564250000
5
A S
B
A S
A S
A S
6
4
B
8
B
B
1…8
A S
B
A
S
B
8
B
A
A
n.c.
S
PA(3)
Shielding (4)
PA+
(1)
B
S
B
Seen in the
direction of the socket.
19. xyzljsdöaklsd
Profibus/Accessories
150/300 mm
Locating plug-in
connector (1)
Cable plug (2)
Positioning piece
Cable socket
2-pole field-bus cable
with screen (O.D.
approx. 8 mm)
fitted by customer.
for field devices.
T-piece can be
freely positioned
2-pole field-bus cable
with screen (O.D.
approx. 8 mm)
fitted by customer.
approx. 59
approx 35
Thread PG 13.5/M20
Sealing ring
Locknut SW 24
Coupling sleeve
M18/PG 13.5 SW 19
incl. insulating sleeve
Thread M 18
Cable fitting see
PROFIBUS-PA installation
recommendations
9459060000
ø 19,5
Knurled screw
Knurled screw
Rotating knurled screw
approx. 54
Clamping screw
ø 19,5
Cable fitting standard Cable
fitting EMC, see installation
recommendations
9459060000
Knurled screw
Rotating knurled screw
Rotating knurled screw
Thread M 12 x 1
Thread M 12 x 1
Front view of pin insert and pins Male PROFIBUS-PA:
Ordering data
A
PA-
S
Screen
B
PA+
n.c.
not connected
Technical data
Type
Locating plug-in connector PG 13.5 150 mm (1)
Locating plug-in connector PG 13.5 300 mm (1)
Locating plug-in connector M 20 150 mm (1)
Locating plug-in connector M 20 300 mm (1)
Cable plug for laid assembly (2)
Cable socket for laid assembly (3)
Part No.
9455650000
8425910000
8425930000
8425940000
9455640000
8426220000
Poles
Type of connection
Cross-sectional area of connection
Connecting thread
Contact surface
Housing protection to DIN 40050 IEC 529
Material of housing
Inflammability to UL - 94
Operating temperature
Rated current per contact
Nominal voltage to VDE standard 0110/ISO group C
Tracking resistance
Volume resistivity to IEC512 part 2
Insulation resistance to IEC 512 part 2
Locating plug-in connector
for field device connection
4 Poles
screwed
0.75 mm2
PG 13.5 / M 20
CuZnAu
IP 67
Cu Zn surface nickel
V-2
- 40 º C .... 85 º C
3A
125 V ~ 150 V =
KC 600
≥8m≥
≥ 10 12 Ω
Cable plug/socket
4 Poles
screwed
0.75 mm2
M 12
CuZnAu
IP 67 with cable ø 4 - 9 mm
Cu Zn surface nickel
V-2
- 25 º C .... 85 º C
3A
125 V ~ 150 V =
KC 600
≤8mΩ
≥ 10 12 Ω
Installation advice
Torques
Screw terminals
Coupling ring PG cable gland
Clamping screw
Knurled screw
hand-tight
Lock nut
6.25 Nm
Torques
0.4 Nm
4.0 Nm
1.8 - 2.0 Nm
hand-tight
Where the possibility of vibration at the field instrument
exists, we recommend installation of a connecting cable
to decouple the vibration source
Preassembled Cables for Field-Bus Distributor Profibus PA
Designation
Intrinsically Safe Area Exi
one-sided preass. cable plug
M12 EMC/blue/1M
M12 EMV/blue/2M
M12 EMV/blue/5M
M12 EMV/blue/10M
one-sided preass. cable socket
M12 EMV/blue/1M
M12 EMV/blue/2M
M12 EMV/blue/5M
M12 EMV/blue/10M
preass. plug - cable socket
M12 EMV/blue/1M
M12 EMV/blue/2M
M12 EMV/blue/5M
M12 EMV/blue/10M
Type
Profibus-PA cable
Part No.
Length
Colour
FBCEX PA M12 M 1m
FBCEX PA M12 M 2m
FBCEX PA M12 M 5m
FBCEX PA M12 M 10m
1785150100 1 m
1785150200 2 m
1785150500 5 m
1785151000 10 m
blue
blue
blue
blue
Exi
Exi
Exi
Exi
FBCEX PA M12 FM 1m
FBCEX PA M12 FM 2m
FBCEX PA M12 FM 5m
FBCEX PA M12 FM 10m
1785140100 1 m
1785140200 2 m
1785140500 5 m
1785141000 10 m
blue
blue
blue
blue
Exi
Exi
Exi
Exi
FBCEX PA M12 M-FM 1m
FBCEX PA M12 M-FM 2m
FBCEX PA M12 M-FM 5m
FBCEX PA M12 M-FM 10m
1785130100 1 m
1785130200 2 m
1785130500 5 m
1785131000 10 m
v
blue
blue
blue
Exi
Exi
Exi
Exi
Designation
Intrinsically Safe Area Exi
one-sided preass. cable plug
M12 EMV/black/1M
M12 EMV/black/2M
M12 EMV/black/5M
M12 EMV/black/10M
one-sided preass. cable socket
M12 EMV/black/1M
M12 EMV/black/2M
M12 EMV/black/5M
M12 EMV/black/10M
preass. plug - cable socket
M12 EMV/black/1M
M12 EMV/black/2M
M12 EMV/black/5M
M12 EMV/black/10M
F > field / B > bus / C > cable / PA > process automation / EX > EX area / M12 > connector / M > male / FM > female
Type
Profibus-PA cable
Part No.
Length
Colour
FBC PA M12 M 1m
FBC PA M12 M 2m
FBC PA M12 M 5m
FBC PA M12 M 10m
1785120100 1 m
1785120200 2 m
1785120500 5 m
1785121000 10 m
black
black
black
black
/
/
/
/
FBC PA M12 FM 1m
FBC PA M12 FM 2m
FBC PA M12 FM 5m
FBC PA M12 FM 10m
1785110100 1 m
1785110200 2 m
1785110500 5 m
1785111000 10 m
black
black
black
black
/
/
/
/
FBC PA M12 M-FM 1m
FBC PA M12 M-FM 2m
FBC PA M12 M-FM 5m
FBC PA M12 M-FM 10m
other lengths on request
1785100100 1 m
1785100200 2 m
1785100500 5 m
1785101000 10 m
black
black
black
black
/
/
/
/
19
20. Profibus DP fieldbus connectors FB Con
xyzljsdöaklsd
• In aluminium and stainless steel housing
• With cable gland and M12 connection
Earthing thread M 4
Erdungsgewinde M4
it is recommended that
empfohlen wird die
Verwendung eines
cable lugs be used
Shield is connected to the enclosure via
the EMC cable glands
Kabelschuhs
g
Pressure compensation
element
Druckausgleichselement
Strip fieldbus cable
Feldbuskabel hier here
abisolieren
Fieldbus cable
Feldbuskabel
Shielding
Schirmgeflecht
19
6
58
8
50 70
Draw back the shielding braid over
Schirmgeflecht ber Mantel
the sheath of the fieldbus cable
des Feldbuskabels schlagen
Druckschraube, to the enclosure via the EMC cable das unvorbereitete
Shield is connected Dichtung der Verschraubung auf glands.
Feldbuskabel auff deln.
Thread the clamping screw, seal of the connection on to the unprepared fieldbus cable
64
B
S Shielding
S
A
A PROFIBUS-DP
Enclosure
A
n.c. n.c.
A
S
S
B
B
Technical Data
Pin No.
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Cable gland
Connection Conductor
Not connected
RxDx/TxD-N / A-conductor
Not connected
RxDx/TxD-N / B-conductor
Shield
Shield
Socket B-coded
1
green
Operating temperature
Protection class
Enclosure material
Surface
–20 to 55 °C
IP 66
High-grade aluminum alloy (AL - Si 12)
painted RAL 7001
Cable entry
Clamping range
Surface of contact
Transmission rate
RS70 DP -T-connector
Brass EMC cable gland M 16
5.5 – 9.5 mm
M12 plug/socket CuZnAU
Max. 1.5 Mbaud
tension clamp 0,5 - 1,5 mm
red
Installation advice
2
5
4
color
3
Screw terminals
M16 cable glands on the enclosure
Union screw M 16 cable glands
Enclosure lid
External earth connection
0.4 Nm
6.0 Nm
4.0 Nm
1.8 – 2.0 Nm
1.8 – 2.0 Nm
Ordering data
RS70 DP-T-Connector
20
Description
Profibus DP T connector with Termination and cable gland
Profibus DP T connector with Termination and cable gland
Profibus DP T connector with Termination and M12
Profibus DP T connector with cable gland
Profibus DP T connector with M12
Profibus DP T connector with Termination (steenless steel) CG
Profibus DP T connector with Termination (steenless steel) M12
Profibus DP T connector (steenless steel) with cable gland
Profibus DP T connector (steenless steel) with M12
M 12 DP B-coded connector
M 12 DP B-socket
Prepared cable with connector 0.3 m
Positioning connection
Profibus DP T connector in IP 20, with tension clamp connection
Type
FBCon DP CG Term 24V
FBCon DP CG Term 5V
FBCon DP M12 Term 24V
FBCon DP CG 1 way
FBCon DP M12 1 way
FBCon SS DP CG Term 24V
FBCon SS DP M12 Term 24V
FBCon SS DP CG 1 way
FBCon SS DP M12 1 way
SAI SM 5/8S M12 5P B-COD
SAI BM 5/8S M12 5P B-COD
SAI L-M12G-PB-DP-0,3
POS-5P M12/M20 300MM
RS DP-T Connector
Part No.
8564290000
8564320000
8564330000
8564340000
8564350000
8714240000
8714250000
8714260000
8714270000
1784790000
1784780000
1810520030
1795500000
8655280000
Qty.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Subject to technical alterations and amendments without notice · Printed in Germany · 5637850000· 09/2003 · DMD