This document provides instructions for various maintenance and troubleshooting tasks on telecommunications equipment, including:
- Checking software processes and applications running on the system.
- Viewing and acknowledging alarms.
- Forcing a laser on/off.
- Backing up and restoring the MIB database.
- Replacing a SMEC card and restoring configuration.
- Viewing board version information and inventory.
- Configuring cross-connections and the LAPD interface.
1. PRÁTICA 1320 CT 1664
COMO VERIFICAR SOFTWARE
> CT ENVIRONENT > PROCESS CONTROL
VERIFICA SE TODOS OS PROCESSOS ESTÃO VERDE, SE TIVER ALGUM
VERMELHO ESTÁ COM FALHA.
> LIST SOFTWARE
VERIFICA TODOS OS APLICATIVOS EM USO.
> MUDAR NSAP (BOTÃO DA DIREITA NO NSAP)
> SETTINGS > OTHER SETTINGS (MUDA SIGLA DA ESTAÇÃO)
ALARMES
DIAGNOSES > ALARMES > NE ALARMES
PARA VER ONDE ESTÁ O ALARME CLICA NA LINHA DE ALARME >
NAVIGATION > EXTERNAL APLICATION > EML-USM
FORÇAR LASER
ENTRA NO AGREGADO > CLICA NO BLOCO (IRÁ MOSTRAR A TELA DE VC4,
AU4)
CLICA NO BLOCO SPI
> PORT > PHISICAL MEDIA > ALS MANAGMENT > ALS FUNCTION (FORÇAR
EM ON) > APPLY
APARECERÁ = LASER CORRENT STATE (FORCED ON)
ALS ENABLE
BACKUP
MIB MANAGEMENT > DIGITA ESTAÇÃO > BACKUP (CLICA CANCEL = OK)
COPIAR A MIB PARA UMA PASTA DE DESTINO
CRIAR UMA PASTA DENTRO DO DIRETÓRIO “ C “ DO COMPUTADOR COM O
NOME DA ESTAÇÃO EX MCL-CEN
SELECIONA NE > SUPERVISION > FILES ADMINISTRATION > MIB COPIES >
SAVE TO DISK
CLICA EM FIND NOW > MARCA O ARQUIVO DESJADO > OK (APARECERÁ O
DIRETÓRIO)
CLICA NA PASTA ONDE SE DESEJA COPIAR > ABRIR (APARECERÁ – THE
SELECTED MIB HAS BEEN COPIED TO C: MCL-CEN / B3_5)
2. TROCAR SMEC
1 2 DIP SWITCH
ON OFF POSIÇÃO NORMAL
OFF ON POSIÇÃO LIMPEZA DE BANCO DE DADOS
OFF OFF RECUPERAR LOCAL CONFIGURATION (NE, OS ADRESS,
LAPD, ETHERNET).
ON ON RETAURAR O BANCO DE DADOS
ON OFF POSIÇÃO NORMAL
PASSOS:
PASSO 1 - RETIRAR A SMEC DIP 1 OFF DIP 2 ON – INSERIR A PLACA E
AGUARDA OS LED URG E NURG ACENDER. (O BANCO FOI LIMPO).
PASSO 2 - RETIRAR A SMEC DIP I OFF DIP 2 ON – INSERIR A PLACA, AGUARDA
OS LED URG E NURG ACENDER.(FOI RECUPERADO LOCAL CONFIGURATION).
PASSO 3- RETIRAR A SMEC DIP I ON DIP 2 ON – INSERIR A PLACA, AGUARDA
OS LED URG E NURG ACENDER.(ENVIAR AS TABELAS DE BACKUP AO NE).
PASSO 4 - RETIRAR A SMEC DIP I ON DIP 2 OFF – INSERIR A PLACA, AGUARDA
OS LED URG E NURG ACENDER.
RESTORE
SUPERVISION > FILES ADMINISTRATION > MIB COPIES > LOAD FRON DISK >
BROUSE > SELECIONA PASTA DA ESTAÇÃO (MCL-CEN) > MARCA O ARQUIVO
(B3_5) > OPEN > FIND NOW (MARCA) > OK
APARECE A MENSAGEM (PACKAGE INSTALLED SUCESFULLY)
VERSÃO DA PLACA
DOWNLOAD > UNITS INF (APARECE OS 2 BANCOS DE VERSÃO)
SOFTWARE UNITS DETAILS (PERMITE VER DETALHES DAS VERSÕES DE
CADA UNIDADE)
INVENTÁRIO
SUB INTEIRO
SUPERVISION > UPLOAD REMOTE INVENTORY > OK ..... AGUARDA!!!
3. DIAGNOSES > VIW > REMOTE INVENTORY > APARECE ARQUIVO BLOCO DE
NOTAS
POR SLOT
SELECIONA O SLOT > REMOT INVENTORY > BOARD LEVEL
CROSS CONEXÃO
CONFIGURATION > CROSS CONECTION MANAGEMENT > SEARCH
(VISUALISA AS CROSS EXISTENTES)
INSERIR NA GERÊNCIA
ABRIR NE > SHOW EQUIPMENT > CLICA NO EQUIPAMENTO >
CONFIGURATION > COMM / ROUTING > LAPD CONFIGURATION
A) 18 YES LAPD INTERFACE YES
USER – LAPD ROLE “ N “ OU “ U “ (DE ACOEDO COM O PROJETO)
17 YES OU NETWORK
B) SÓ PARA GNE´S CONFIGURAR ETHERNET Q3
OBS: GNE É QUANDO SE LIGA A SAÍDA “ Q3 “ NA “ REDE DCN ” E LIGA NO
EQUIPAMENTO DE GERÊNCIA.
YES – SE COLOCAR EM “ NO ” IRÁ RESETAR A SMEC
NO – (L2 ONLY)
ALARME DE LAPD – CSF
SE O PROBLEMA FOR NO Q3, LAN FAILURE OU Q3 FAILURE.
C) OS ADRESS
CONFIGURATION > OS COFIGURATION
NSAP DA GERÊNCIA (13535H)
COLOCAR SOMENTE A GERÊNCIA PRINCIPAL (SEGUIR PROJETO)
GERÊNCIA SPARE (MENOS USADA)
NSAP
39 – FORMATO
076F – BRASIL
80 – PADRÃO
000000 – RESERVADO
0000 – OPERADORA
0001 – DOMÍNIO
0001 – ÁREA
002060ABCDEF – SISTEM ID
4. ID – SELECTOR
D) LOCAL CONFIGURATION > NSAP DO NE
SYNCRONISMOUS AREA ADRESS OPTICAL (NÃO INSERIR)
SISTEM TYPE
MARCAR > INTERMEDIATE SYSTEM LY
ACESSO REMOTO
MAP > SAMPLE > NE DIRECTORY > CREATE Q3NE
AF1 39
ID
REPETIR O PROCESSO PARA CADA NE. (SALVAR ATRAVES DO MAPE SAVE)
LIMPAR ALARMES NORMALIZADOS
NA TELA DE ALARMES
SELECIONA TODOS > ACTION > ACKNOWLEDGE...
VER ONDE ESTÁ O ALARME
CLICA NO ALARME > NAVIGATION > EXTERNAL APLICATION > EML-USM
HOUSEKIPING
ALARMES EXTERNOS > ENTRA NO AGREGADO > VIWS > EXTERNAL POINTS
CRIAR TELECOMANDO
EXTERNAL POINTS > CONFIGURATION > USER LABEL > NOME DO
TELECOMANDO > EXTERNAL STATE OFF (ON ENVIA O TELECOMANDO)
OUTPUT CRITÉRIA > DEFINE DE QUE FORMA SERÁ O TELECOMANDO
EX: MANUAL
CRIAR TELESSINA
EXTERNAL POINTS > CONFIGURATION > USER LABEL > NOME DO
TELESSINAL > EXTERNAL STATE OFF (ON ENVIA O TELESSINAL)
PARA VISUALIZAR A DESCRIÇÃO DO ALARME NA TELA DE ALARMES
SUBLIST > MODIFY > SELECIONA ADDITIONAL TEST > CLICA NA SETA A
DIREITA > APLLY > CLOSE
5. SINCRONISMO
NATELA DE EQUIPAMENTO
1) CLOCK: EXTERNO
IMPUT: 2MHz T3 # A
QUALITY: G811
PRIORITY: 1
VIEWS > SINCRONIZATION VIW > SELECIONA > SINCRONIZATION > TIMING
SOURCE CONFIGURATION > CHOOSE > RACK 1 (ABRIR) > SUBMARCK (ABRIR)
> CRU – 6 > 2MHZ T3 # A (MARCA 2MHz T3 # A > OK
OBS: FONTE DE RELÓGIO EXTERNA = GPS
2) CLOCK: RECUPERADO
IMPUT: SL....-OPS
QUALITY: EXTRATED
PRIORITY: 2
VIEWS > SINCRONIZATION VIW > SELECIONA > SINCRONIZATION > TIMING
SOURCE CONFIGURATION > CHOOSE > RACK 1 (ABRIR) > SUBMARCK (ABRIR)
>AGG 16 5161 NEW 17 > MARCA OPS > OK > IMPUT QUALITY (EXTRATED) >
OK > PRIORITY 2 > OK
3) T0 CONFIG
SINCRONIZATION > T0 CONFIG > MARCA SSM ALGORITHM ENABLING > OK
O SISTEMA ESCOLHE O RELÓGIO PRIMEIRO PELA QUALIDADE, DEPOIS PELA
PRIORIDADE.
PARA EXTERIORIZAR RELÓGIO > SINCRONIZATION > T4 CONFIGURATION 811
E 813