Lisun Electronics provides a brochure describing their LSG-5000 Moving Detector Goniophotometer system for measuring the photometric properties of luminaires. The system includes a goniometric rotating console, photometer, software and various accessories. It is capable of measuring properties such as luminous intensity distribution, beam angles, efficiency and more in accordance with various international standards. The document provides details on system components, measurement principles, specifications, laboratory requirements and applications.
LSG-5000 Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
Test intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Japanese motor, German Angle Coder and Constant Temperature Class L Detector to keep high accuracy. Both B-Beta & C-Gamma test for all luminaires up to 1.4m and 40kg
LSG-5000 CCD Moving Detector Goniophotometer is full meet LM-79 Clause 9.3.1 request. The tested lamp will keep burning position and be fixed, near field detector move together with the big mirror in a line, and the far field detector will move with the big mirror synchronously. The detector will always sense the light directly from the luminaries.
LSG-2000 Goniophotometer with Rotating Mirror also called the Moving Mirror Goniophotometer. The LSG-2000 is an automatic light distribution intensity 3D curve testing system. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
Test intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Japanese motor, Angle Coder and Constant Temperature Class A Detector to keep high accuracy. Both B-Beta & C-Gamma test for all luminaires up to 1.4m and 40kg
LSG-5000 Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
LSG-3000 Moving Detector Goniophotometer is full meet LM-79 Clause 9.3.1 request. The tested lamp will keep burning position and be fixed, near field detector move together with the big mirror in a line, and the far field detector will move with the big mirror synchronously. The detector will always sense the light directly from the luminaries.
LSG-5000 Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
Test intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Japanese motor, German Angle Coder and Constant Temperature Class L Detector to keep high accuracy. Both B-Beta & C-Gamma test for all luminaires up to 1.4m and 40kg
LSG-5000 CCD Moving Detector Goniophotometer is full meet LM-79 Clause 9.3.1 request. The tested lamp will keep burning position and be fixed, near field detector move together with the big mirror in a line, and the far field detector will move with the big mirror synchronously. The detector will always sense the light directly from the luminaries.
LSG-2000 Goniophotometer with Rotating Mirror also called the Moving Mirror Goniophotometer. The LSG-2000 is an automatic light distribution intensity 3D curve testing system. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
Test intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Japanese motor, Angle Coder and Constant Temperature Class A Detector to keep high accuracy. Both B-Beta & C-Gamma test for all luminaires up to 1.4m and 40kg
LSG-5000 Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
LSG-3000 Moving Detector Goniophotometer is full meet LM-79 Clause 9.3.1 request. The tested lamp will keep burning position and be fixed, near field detector move together with the big mirror in a line, and the far field detector will move with the big mirror synchronously. The detector will always sense the light directly from the luminaries.
LSG-3000 CCD Moving Detector Goniophotometer is full meet LM-79 Clause 9.3.1 request. The tested lamp will keep burning position and be fixed, near field detector move together with the big mirror in a line, and the far field detector will move with the big mirror synchronously. The detector will always sense the light directly from the luminaries.
LSG-2000 Goniophotometer with Rotating Mirror is also called the Moving Mirror Goniophotometer. It is an automatic light distribution intensity 3D curve testing system.
Full meet LM-79 Clause 9.3.1, GB, CIE & IEC Standards. Test intensity distribution curve in 3D & export IES files for DiaLux. It can test all kinds of luminaires which length up to dia=0.6m and max 20kg
LSG-1900B Goniophotometer is high precision auto matic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1900B use a constant temperature detector Japanese Motor which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaires.
High precision-rotation-luminaire-goniospectroradiometer世满 江
LSG-1800BCCD goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurement with facility for rotating the light source.
LISUN Near field-type-c-goniophotometer LSG-1900B世满 江
LSG-1900B Goniophotometer is near field Type C automatic goniophotometric instrument for luminous intensity distribution measurement. The LSG-1900B uses a constant temperature detector. It is for industrial laboratory photometric data measurements of small luminaires, such as down light, bulb light, etc.
Lisun LSG-1950 is a CIE A-α goniophotometer. The photometer head keeps static and it faces to the sample under test while the sample is rotating around both horizontal axis and vertical axis.
Rotation Luminaire Goniophotometer (Big Size)Lisun Group
Test intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Taiwan motor and Constant Temperature Detector to keep high accuracy. Test all luminaires up to 1.6m and 40kg
LSG-1800/LSG-1700 Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800 is an update version for LSG-1700, the LSG-1800 use a high accuracy Motor and precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
Lisun Goniospectroradiometer with Moving Mirror can test luminaries rotating in the presscribed burning position and around the vertical axle and a reflecting mirror rotates around the horizontal axle, meanwhile, a synchronous axle will rotate toward the opposite direction synchronously.
LISUN Goniophotometer for Automotive and Signal Lamps Lsg-1950世满 江
LSG-1950 is the CIE A-α Goniophotometer. The photometer head keeps static and face to the test sample while the test sample rotates around both horizontal axis and vertical axis, so the luminous intensity and illuminance of the tested lamp or luminaires can be tested.
LSG-3000 CCD Moving Detector Goniophotometer is full meet LM-79 Clause 9.3.1 request. The tested lamp will keep burning position and be fixed, near field detector move together with the big mirror in a line, and the far field detector will move with the big mirror synchronously. The detector will always sense the light directly from the luminaries.
LSG-2000 Goniophotometer with Rotating Mirror is also called the Moving Mirror Goniophotometer. It is an automatic light distribution intensity 3D curve testing system.
Full meet LM-79 Clause 9.3.1, GB, CIE & IEC Standards. Test intensity distribution curve in 3D & export IES files for DiaLux. It can test all kinds of luminaires which length up to dia=0.6m and max 20kg
LSG-1900B Goniophotometer is high precision auto matic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1900B use a constant temperature detector Japanese Motor which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaires.
High precision-rotation-luminaire-goniospectroradiometer世满 江
LSG-1800BCCD goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurement with facility for rotating the light source.
LISUN Near field-type-c-goniophotometer LSG-1900B世满 江
LSG-1900B Goniophotometer is near field Type C automatic goniophotometric instrument for luminous intensity distribution measurement. The LSG-1900B uses a constant temperature detector. It is for industrial laboratory photometric data measurements of small luminaires, such as down light, bulb light, etc.
Lisun LSG-1950 is a CIE A-α goniophotometer. The photometer head keeps static and it faces to the sample under test while the sample is rotating around both horizontal axis and vertical axis.
Rotation Luminaire Goniophotometer (Big Size)Lisun Group
Test intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Taiwan motor and Constant Temperature Detector to keep high accuracy. Test all luminaires up to 1.6m and 40kg
LSG-1800/LSG-1700 Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800 is an update version for LSG-1700, the LSG-1800 use a high accuracy Motor and precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
Lisun Goniospectroradiometer with Moving Mirror can test luminaries rotating in the presscribed burning position and around the vertical axle and a reflecting mirror rotates around the horizontal axle, meanwhile, a synchronous axle will rotate toward the opposite direction synchronously.
LISUN Goniophotometer for Automotive and Signal Lamps Lsg-1950世满 江
LSG-1950 is the CIE A-α Goniophotometer. The photometer head keeps static and face to the test sample while the test sample rotates around both horizontal axis and vertical axis, so the luminous intensity and illuminance of the tested lamp or luminaires can be tested.
LSG-1800CCD/LSG-1700CCD Goniospectroradiometer is an automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800CCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
this system is used to measure spatial luminous intensity distribution of luminaries for floodlight, street lighting and interior lighting, and other photometric parameters such as spatial iso-intensity curve, intensity distribution curve
LSG-1800CCD/LSG-1700CCD goniospectroradiometer is an automatic goniophotometer instrument for luminous intensity distribution measurement with facility for rotating the light source.
Rotation Luminaire GoniospectroradiometerLisun Group
Test Spatial CCT and intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Taiwan motor, Angle Coder and Constant Temperature Class A Detector to keep high accuracy. B-Beta & C-Gamma test for all lamps up to 1.6m and 40kg
State of ICS and IoT Cyber Threat Landscape Report 2024 previewPrayukth K V
The IoT and OT threat landscape report has been prepared by the Threat Research Team at Sectrio using data from Sectrio, cyber threat intelligence farming facilities spread across over 85 cities around the world. In addition, Sectrio also runs AI-based advanced threat and payload engagement facilities that serve as sinks to attract and engage sophisticated threat actors, and newer malware including new variants and latent threats that are at an earlier stage of development.
The latest edition of the OT/ICS and IoT security Threat Landscape Report 2024 also covers:
State of global ICS asset and network exposure
Sectoral targets and attacks as well as the cost of ransom
Global APT activity, AI usage, actor and tactic profiles, and implications
Rise in volumes of AI-powered cyberattacks
Major cyber events in 2024
Malware and malicious payload trends
Cyberattack types and targets
Vulnerability exploit attempts on CVEs
Attacks on counties – USA
Expansion of bot farms – how, where, and why
In-depth analysis of the cyber threat landscape across North America, South America, Europe, APAC, and the Middle East
Why are attacks on smart factories rising?
Cyber risk predictions
Axis of attacks – Europe
Systemic attacks in the Middle East
Download the full report from here:
https://sectrio.com/resources/ot-threat-landscape-reports/sectrio-releases-ot-ics-and-iot-security-threat-landscape-report-2024/
PHP Frameworks: I want to break free (IPC Berlin 2024)Ralf Eggert
In this presentation, we examine the challenges and limitations of relying too heavily on PHP frameworks in web development. We discuss the history of PHP and its frameworks to understand how this dependence has evolved. The focus will be on providing concrete tips and strategies to reduce reliance on these frameworks, based on real-world examples and practical considerations. The goal is to equip developers with the skills and knowledge to create more flexible and future-proof web applications. We'll explore the importance of maintaining autonomy in a rapidly changing tech landscape and how to make informed decisions in PHP development.
This talk is aimed at encouraging a more independent approach to using PHP frameworks, moving towards a more flexible and future-proof approach to PHP development.
Key Trends Shaping the Future of Infrastructure.pdfCheryl Hung
Keynote at DIGIT West Expo, Glasgow on 29 May 2024.
Cheryl Hung, ochery.com
Sr Director, Infrastructure Ecosystem, Arm.
The key trends across hardware, cloud and open-source; exploring how these areas are likely to mature and develop over the short and long-term, and then considering how organisations can position themselves to adapt and thrive.
Accelerate your Kubernetes clusters with Varnish CachingThijs Feryn
A presentation about the usage and availability of Varnish on Kubernetes. This talk explores the capabilities of Varnish caching and shows how to use the Varnish Helm chart to deploy it to Kubernetes.
This presentation was delivered at K8SUG Singapore. See https://feryn.eu/presentations/accelerate-your-kubernetes-clusters-with-varnish-caching-k8sug-singapore-28-2024 for more details.
Transcript: Selling digital books in 2024: Insights from industry leaders - T...BookNet Canada
The publishing industry has been selling digital audiobooks and ebooks for over a decade and has found its groove. What’s changed? What has stayed the same? Where do we go from here? Join a group of leading sales peers from across the industry for a conversation about the lessons learned since the popularization of digital books, best practices, digital book supply chain management, and more.
Link to video recording: https://bnctechforum.ca/sessions/selling-digital-books-in-2024-insights-from-industry-leaders/
Presented by BookNet Canada on May 28, 2024, with support from the Department of Canadian Heritage.
UiPath Test Automation using UiPath Test Suite series, part 3DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 3. In this session, we will cover desktop automation along with UI automation.
Topics covered:
UI automation Introduction,
UI automation Sample
Desktop automation flow
Pradeep Chinnala, Senior Consultant Automation Developer @WonderBotz and UiPath MVP
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
"Impact of front-end architecture on development cost", Viktor TurskyiFwdays
I have heard many times that architecture is not important for the front-end. Also, many times I have seen how developers implement features on the front-end just following the standard rules for a framework and think that this is enough to successfully launch the project, and then the project fails. How to prevent this and what approach to choose? I have launched dozens of complex projects and during the talk we will analyze which approaches have worked for me and which have not.
UiPath Test Automation using UiPath Test Suite series, part 4DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 4. In this session, we will cover Test Manager overview along with SAP heatmap.
The UiPath Test Manager overview with SAP heatmap webinar offers a concise yet comprehensive exploration of the role of a Test Manager within SAP environments, coupled with the utilization of heatmaps for effective testing strategies.
Participants will gain insights into the responsibilities, challenges, and best practices associated with test management in SAP projects. Additionally, the webinar delves into the significance of heatmaps as a visual aid for identifying testing priorities, areas of risk, and resource allocation within SAP landscapes. Through this session, attendees can expect to enhance their understanding of test management principles while learning practical approaches to optimize testing processes in SAP environments using heatmap visualization techniques
What will you get from this session?
1. Insights into SAP testing best practices
2. Heatmap utilization for testing
3. Optimization of testing processes
4. Demo
Topics covered:
Execution from the test manager
Orchestrator execution result
Defect reporting
SAP heatmap example with demo
Speaker:
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
The Art of the Pitch: WordPress Relationships and SalesLaura Byrne
Clients don’t know what they don’t know. What web solutions are right for them? How does WordPress come into the picture? How do you make sure you understand scope and timeline? What do you do if sometime changes?
All these questions and more will be explored as we talk about matching clients’ needs with what your agency offers without pulling teeth or pulling your hair out. Practical tips, and strategies for successful relationship building that leads to closing the deal.
GraphRAG is All You need? LLM & Knowledge GraphGuy Korland
Guy Korland, CEO and Co-founder of FalkorDB, will review two articles on the integration of language models with knowledge graphs.
1. Unifying Large Language Models and Knowledge Graphs: A Roadmap.
https://arxiv.org/abs/2306.08302
2. Microsoft Research's GraphRAG paper and a review paper on various uses of knowledge graphs:
https://www.microsoft.com/en-us/research/blog/graphrag-unlocking-llm-discovery-on-narrative-private-data/
1. Brochure
Global Office of Lisun Electronics Inc.
http://www.Lisungroup.com
Lisun Group (Hong Kong) Limited
Add: Room 803, Chevalier House, 45-51 Chatham Road South, Tsim Sha Tsui, KL, HK
Tel: 00852-68852050 Fax: 00852-30785638
Email: SalesHK@Lisungroup.com
Lisun Electronics (Shanghai) Co., Ltd
Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading
District, Shanghai, 201802, China
Tel: +86(21)5108 3341 Fax: +86(21)5108 3342
Email: SalesSH@Lisungroup.com
Lisun Electronics Inc. (USA)
Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A.
Email: Sales@Lisungroup.com
Lisun China Factory
Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China
Tel: +86-189-1799-6096
Email: Engineering@Lisungroup.com
Leader in Lighting & Electrical Test Instruments
Rev. 2/14/2020
Moving Detector
Goniophotometer
(LSG-5000)
2. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 1 -
1.System Configuration
A. LSG-5000 Goniophotometric System:
Goniometric Rotating Console: Japanese Mitsubishi Motor and German
Angle encoder System to keep the test accuracy. Both Far Field and Near
Field Test.
High Reflective Moving Mirror: Special design and produced to keep high
reflective value.
Goniometric Rotating Control Instrument in 19inch cabinet: It connects
to the PC and was controlled by the software.
Goniometric Rotating Control Instrument in dark room: This can allow
the customer to control the rotating in the dark room when install the
lumainires but no need to control in the PC.
Double Channel & High Precision Photometer
Germany produced Class L Constant Temperature Photo Detector
Cross-beam Laser System for Calibrating
English Measuring Software
Automatic Adjust Diaphragm: remote control to adjust the size of
diaphragm for the different diameter size luminaries test
Two sets of luminaries Clamps: multi-functions
Oversea Delivery and Packing: all of the instruments and accessories will
be packed with Fumigation free three plywood, include the delivery cost
to Shanghai sea port
B. SLS-150W DC Standard Light Intensity Lamp
C. LS2010 Digital Power Meter: High Accuracy to measure AC voltage, current,
power and power factor, also measure harmonic
D. DC3010 CC & CV DC Power Source: DC3010 output is 30V/10A, Option can
be DC6010 (output is 60V/10A) and DC12010 (output is 120V/10A)
E. LSP-1KVAR AC Power Source: 1KVA Pure Sine Wave AC Power Source
F. CASE-19IN 19inch Standard Instruments Cabinet.
Full View for LSG-5000 Moving Detector Goniophotometer
Note: PC and Printer prepared by the customer (request at least one USB port)
3. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 2 -
2. Measurement Principle
LSG-5000 Moving Detector Goniophotometer is full meet LM-79 Clause 9.3.1
request. The tested lamp will keep burning position and be fixed, near field detector
move together with the big mirror in a line, and the far field detector will move with
the big mirror synchronously. The detector will always sense the light directly from
the luminaries.
The rotation priority is determined by the software. If mirror axle is took precedence
of rotation, the goniophotometer will continuously measure the luminous intensity
at each γ angle on a vertical plane determined by the C angle, the measuring trace
is equivalent to the longitude. Similarly, while the luminaries axle is priority, the
system will continuously measure the luminous intensity at each C angle on a
conical surface determined by the γ angle, the trace can be looked upon the woof.
See the following figure.
Measurement Principle
3. System Functions
4. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 3 -
The LSG-5000 full meet LM-79 Clause 9.3.1, CIE and GB standards for
Goniophotometric of luminaries, this system is used to measure spatial luminous
intensity distribution of luminaries for floodlight, street lighting and interior lighting,
and other photometric parameters such as spatial iso-intensity curve, intensity
distribution curve of each section (shown in rectangular coordinate system or polar
coordinate system), iso-illuminance distribution curve, luminance limitation curve,
luminaries efficiency, glare grade, effective beam angles, upward luminous flux ratio,
downward luminous flux ratio, total luminous flux, effective luminous flux,
utilization factor and electric parameters (wattage, power factor, voltage and
current) of luminaries etc.
LSG-5000 Can test all of the above luminaires
4. Specifications
1) The tested luminaire rotates around the mirror with an angle of (γ)±180°(or
0-360°) and the tested luminaire rotates around itself with an angle of
(C)±180°(or 0-360°)
2) The accuracy of angle: 0.05° Resolution of angle: 0.001°
3) Luminosity Testing Range: Illuminance 0.001lx~99,999lx; Light Intensity
1.0cd~107
cd(detector)
4) Accuracy of photometry: Germany produced constant temperature photo
detector DIN5032-6/CIE pub1. No. 69 Class L
5) Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1%
6) English version software can run in Win7, Win8 or Win10
PS. The LSG-5000X are special size which According to customer’s request
Model Number
LSG-5000B
(Big Size)
LSG-5000
(Standard Size)
LSG-5000S
(Standard Size)
Measure Size (mm) Diameter=1600 Diameter=1400 Diameter=900
Measure Weight (Kg) 50 40 30
Measure Power(W) 600V/10A,AC/DC 600V/10A,AC/DC 600V/10A,AC/DC
5. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 4 -
5. Laboratory Requirements
1) Room Requirements according to CIE
Model Dark Room (W*H*L) Operation Room(W*L)
LSG-5000B 5*5*8~30m 4*4m
LSG-5000 4*4*8~30m 4*4m
LSG-5000S 4*3*8~30m 4*4m
P.S. The LSG-5000X Lab room size will special design
The dark room wall, ceiling and floor should be all coated with dull black paint or
be covered by black cloth and black carpet.
Air-conditioner: be set in the dark room to control the temperature around
lamps to the standard value upon the CIE requirements.
Note: LISUN GROUP engineer dept will submit the Lab Design support documents
according to the customer’s real lab size after the formal purchase order was
confirmed
Fig: LSG-5000 lab dark room view
6. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 5 -
2) Requirements of Eliminating the stray Light
Luminaires must be where the photo detector can only receive the light
reflected by the two moving mirror in the LSG-5000 system. The light given
off directly by the luminaries and reflected by the wall and floor is warded
off by the light fence. Internal surface of the dark room and dark path
together with the surface of the light fence should be painted unpolished
black or be covered by black cloth and black carpet.
3) Temperature of the Environment
Temperature around the lamp or luminaries must be 25℃±1℃ during the test.
Exceptions can be given according to relative lamps as following.
a. Tungsten Incandescent Lamp: 25℃±5℃
b. Double-caps Fluorescent Lamp: 25℃±1℃
c. High Pressure Mercury Lamp: 25℃±2℃
d. Metal Halogen Lamp: 25℃±2℃
e. High Pressure Sodium Lamp: 25℃±2℃
f. Low Pressure Sodium Lamp: 25℃±2
4) Airflow
Airflow may be induced by natural aeration, air conditioner or movement of the
luminaries in the goniophotometer, but the speed of the airflow couldn’t
exceed 0.2m/s.
5) Vibration and shock
When the lamp is in lighting, the vibration couldn’t exceed 10m/s2(4 ~
3000Hz), or the moving scope of the lamp couldn’t exceed 30mm (at most
4Hz)
6) Smoke, Dust and Moisture
The test environment must free from smoke, dust or moisture. At the same
time, even not during the measurement, smoke, dust or moisture will also
influence the reflectance of the reflecting mirror and induce more stray light.
So, the test room must be kept clean, no smoke and dry. The humidity should
be less than 60% RH.
6. Service
1) Installation and Training
LISUN GROUP engineers will take responsibility for installation and Training of
the system at the customer’s
2) Period of Guarantee: 24 months
The service is for free except technician’s travel payment if the service
provided by LISUN GROUP implement at the customer’s.
3) Upgrading the applications software for free
7. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 6 -
7. Design Standard of Device
The construction, technical parameter, test & operate steps as well as data
processing software of LSG-5000 Moving Detector Goniophotometer meet the
following requirements:
3.1 CIE Pub. NO.70,”The Measurement of Absolute Luminous Intensity
Distributions”
3.2 CIE DIV.Ⅱ-TC10,”Photometry of Luminaires”
3.3 IES LM-35-1989,”IES Approved Method for Photometric Testing of
Floodlights”
3.4 IES LM-31,”IES Approved Method for Photometric Testing of Roadway
Luminaires”
3.5 IES-LM-79, “Electrical & Photometric Measurements of Solid-State Lighting Products”
3.6 GB/T 7002-1986,“Luminosity Test of Flood Luminaires”
3.7 GB/T 9467-1988, “Luminosity Test of Indoor Luminaires”
3.8 GB/T 9468-1988, “Luminosity Test of Street Luminaires”
3.9 IES 61341 “Method of Measurement of Center Beam Intensity and Beam
Angle(s) of Reflector Lamp”
3.10 CIE Pub.NO.76, “Photometry-the CIE System of Physical Photometry”
8. Typical oversea market customers:
There are many world famous company and lab institute choose Lisun
Goniophtometer, Please get the reference customers’ information from Lisun
Group Oversea Sales Dept.
9. Application Software
This system can export data files as following formats:
This kind of format files can be transferred by other illumination and luminaire
design software such as DiaLux
Application software can also implement essential calculation for lighting design as
iso-illuminance distribution curve on a working plane, luminance limitation curve,
luminaire efficiency, effective beam angle, upward luminous flux ratio, downward
luminous flux ratio, effective luminous flux, utilization factor curve etc.
The Next Page is the Test Report by the software of LSG-5000:
8. Lisun Electronics Inc.
http://www.Lisungroup.com
Tel: +86(21)51083341
Fax: +86(21)51083342 Page 1 of 28 Pages
Report No.: LS1127 Test Time: 2017-08-31 13:12
Luminaire Property
Luminaire Manufacturer: W.K.LIGHTING
Luminaire Category: WK-71-83-8077-85-IP65
Lamp Catalog: LUMINUS Lamp Description: Philips
Number of Lamps: 1 Lumens per Lamp: 700
Luminous Length (mm): 8.5 Luminous Width (mm): 8.5
Luminous Height (mm): 12 Voltage: 220.6 V
Current: 0.071 A Power: 8.69 W
Power Factor: 0.559
Photometric Results
CIE Class: Direct Total Rated Lamp Lumens: 700.0 lm
Measurement Flux: 641.8 lm Efficiency: 91.69%
Downward Ratio: 91.69% Upward Ratio: 0.00%
Horizontal Diffuse Angle(50%): H34.6
Vertical Diffuse Angle(50%): V34.1
Luminaire Efficacy Rating (LER): 73.91 Central Intensity: 1617.64 cd
Max. Intensity: 1620.79 cd Pos of Max. Intensity: H22.5 V1
S/MH(C0/C180): 0.57 S/MH(C90/C270): 0.56
Picture Of Luminaire Luminous Intensity Distribution Curve
0
180
9090
1010
170170
2020
160160
3030
150150
4040
140140
5050
130130
6060
120120
7070
110110
8080
100100
2025
1620
1215
810
405
Average Diffuse Angle(50%): 34.3°
C0-C180 C90-C270
Unit: cd
C Plane (°):0.0-360.0: 22.5 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000
Test Type: TYPE C Distance: 8.300 m
Temperature: 24.5 Humidity: 60%
Operator: Joye Inspector:
9. Lisun Electronics Inc.
http://www.Lisungroup.com
Tel: +86(21)51083341
Fax: +86(21)51083342 Page 2 of 28 Pages
Luminous Intensity Distribution Curve
0
180
9090
1010
170170
2020
160160
3030
150150
4040
140140
5050
130130
6060
120120
7070
110110
8080
100100
2025
1620
1215
810
405
-180 -120 -60 0 60 120 180
0
405
810
1215
1620
2025
C0-C180 C90-C270 Unit: cd
C Plane (°):0.0-360.0: 22.5 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000
Test Type: TYPE C Distance: 8.300 m
Temperature: 24.5 Humidity: 60%
Operator: Joye Inspector:
10. Lisun Electronics Inc.
http://www.Lisungroup.com
Tel: +86(21)51083341
Fax: +86(21)51083342 Page 3 of 28 Pages
Luminous Intensity Distribution Curve(cd/klm)
0
180
9090
1010
170170
2020
160160
3030
150150
4040
140140
5050
130130
6060
120120
7070
110110
8080
100100
2894
2315
1736
1157
578
cd/klm
C0-C180
C90-C270
¦Ç=91.69%
LUMINUS/Philips
C Plane (°):0.0-360.0: 22.5 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000
Test Type: TYPE C Distance: 8.300 m
Temperature: 24.5 Humidity: 60%
Operator: Joye Inspector: