MEASUREMENT OF PRESSURE
Module -5 Measurement of Pressure:
• Introduction,
• Diaphragms, Other elastic elements,
• Transduction methods –
• Potentiometric device,
• Strain gauge transducer ,
• Variable reluctance,
• LVDT type,
• Variable capacitance device (principle & working, no derivation),
• Force balance transducer with analysis,
• Thin-film pressure transducers,
• Piezoelectric pressure transducer,
• Pressure multiplexer,
• Pressure calibration.
Module -5
Transducers/Instruments for Measurement of Pressure: Introduction, Diaphragms,
Other elastic elements, Transduction methods – potentiometric device, strain gauge
transducer, variable reluctance, LVDT type, variable capacitance device (principle &
working, no derivation), force balance transducer with analysis, Thin film pressure
transducers, Digital pressure transducer, Piezoelectric pressure transducer, Pressure
multiplexer, Pressure calibration.
Pressure : ( 1 atmospheric pressure =14.7 Psi )
• Force acting per unit area N/m2
• Measurement involved can be static or dynamic.
• Pressure is a compressive stress exerted uniformly in all directions
(considering fluid (can be liquid or Gas) pressure)
• Pressure transducers can be classified as
1. Gravitational type ( Manometer is the simplest device)
2. Elastic type ( Pressure exert force over area of elastic device
example : Diaphragm , Capsule, Bellows, Bourdon tube )
• With respect to applied pressure Elastic device output is
displacement or strain developed and it is measured by electrical
sensor
• The transduction principles (involves) displacement measurements
with resistive (strain gauge), inductive, and capacitive principles or
measurement of change in natural resonance frequency of a
stretched member.
• Accordingly they are classified as potentiometric, bonded and
unbonded strain gauge, piezoresistive, inductive, LVDT, capacitive,
piezoelectric types.
DIAPHRAGMS : (Materials used Elastomers and polyamide, polyester,
polyacrylamide, and rayon staple fiber fabrics)
• Common pressure sensing member
• Consists of a circular plate & fastened (connected) at its periphery.
• Structure can be flat or corrugated.
• Used when high Accuracy required and provide good dynamic
response.
• Main characteristics of diaphragms are
1. Ruggedness
2. Stability
3. Reliability
4. Low Hysteresis
5. Low creep
6. Good dynamic response
• Diaphragms are made from
1. Metal alloys
2. Bronze
3. Phosphor bronze
4. Stainless steel
Diagram shown below is not for exam
• Flat diaphragms can be designed to have high natural
frequencies and as such are ideally suited for dynamic
measurements.
• Due to imperfections in the material and in the
manufacturing process, the Pressure deflection curve can
have certain nonlinear characteristics and other errors, such
as hysteresis.
• To avoid this, the diaphragm is usually stretched radially and
then clamped.
• Deflections of the diaphragm of small magnitude. are mainly
due to bending deformations only.
• With increased load on the diaphragm, when the deflection
reaches the value roughly equal to its thickness, tensile stresses
also develop along with bending and the deflection characteristics
become non-linear.
• For larger deflection requirements, corrugated diaphragms are
ideally suited.
Corrugated Diaphragms:
• corrugated diaphragms are also encountered in pressure
measurements, especially where larger deflections are required
than those normally obtained with flat diaphragms.
• Diaphragm profiles take different forms, such as sawtooth.
trapezoidal, and sinusoidal shapes, as shown in Fig. 7.3
Capsule :
• A capsule consists of two identical annular corrugated metal diaphragms
sealed together at the periphery to obtain a shell like enclosure.
• One of the diaphragms is provided with a central reinforced port to admit the
pressure to be measured, and the other is linked to a mechanical member.
• The displacement of this ,member is proportional to the difference of the
inner and outer pressures.
• The seal is made by brazing, soldering, or electron-beam welding, and the
whole capsule is heat treated to relieve the stresses built up during welding
and subsequent cooling.
• The factors influencing the deflections of the capsule are the same as those
for the diaphragms.
Bourdon Tube:
• The bourdon tube is a curved or twisted metallic tube having an
elliptical cross-section, and scaled at one end.
• The tube tends to straighten out on the application of pressure, and
the angular deflection of the free end is taken as a measure of the
pressure.
• The deflection sensitivity is a function of the aspect ratio of the
tube cross-section.
• The main advantages are high sensitivity and good repeatability.
• The C-shaped tube has a total angle of curvature of 180 to 270°, and
the angular Deflection (output) is normally measured with a
mechanical pointer moving over a calibrated scale or with a
potentiometric or L VDT transducer.
• The deflection of a bourdon tube varies
• With the ratio of its major to minor cross-sectional axis,
• Tube length,
• Difference between the internal and external pressures,
• Radius of curvature, and
• Angle of twist.
• It also varies inversely with the tube wall thickness and the
modulus of elasticity of the material used.
• The angular deflection of the helical-type and C-type
bourdon tubes can be expressed by the equation.
Where Ø = angle of rotation of the tip of the tube.
Ø0 = angle of tube/total angle of helix
P = pressure in pascals
r = radius of the tube/helix in meters
t = wall thickness in meters
E = Young's modulus of material
b = minor axis of the tube, measured from the middle of one
wall to the middle of the other wall, in meters.
PRESSURE MULTIPLEXER :
Problem ?
• In certain experiments, such as wind-tunnel testing of models,
a simultaneous measurement of pressures at various locations is
required for detailed investigations.
• If a pressure transducer is individually used at each pressure
point, the entire equipment tends to be large, expensive, and
cumbersome, since each sensor needs a separate balance
control, zero control and signal conditioner.
ANS : Hence for simultaneous measurement of pressure at various
location pressure multiplexer is used
• However, by incorporating a pressure-transfer valve, the.
pressures at a large number of points can be measured
with a single transducer. A typical pressure multiplexer
system using a scanivalve arrangement is illustrated in Fig.
7.21.
• The scanivalve with 24 or 48 ports is driven either by a
motor or solenoid, and connects a small unbonded strain
gauge type pressure transducer to the pressure ports
sequentially, one at a time.
• The signal from the transducer is processed with a
suitable signal conditioner and converted equivalent
value that is analog / digital printed out or displayed in
required units.
• The transducer is housed within the body of the valve
itself to keep the transfer volume minimum, thereby
ensuring good response even at low pressure levels.
• The maximum speed of sampling can be as high as 48
ports per minute.
• In some experiments it may be necessary to freeze several
unknown pressure values simultaneously and then
measure the pressure magnitudes later for this, cut-off
valves with storage tubes are incorporated ahead. of the
pressure multiplexer.
• The system is extensively used for many aeronautical and
allied measurements.
PRESSURE CALIBRATION: ( pressure gauge calibration)
• A basic standard calibrating device widely used under laboratory
conditions is the hydraulic or pneumatically-operated dead weight
tester.
• Range is from 50 to 50x 106 Pascal's in steps of 0.1% with
an uncertainty of 0.01 to 0.5%.
• The dead-weight tester consists of two accurately
machined cylinders, honed to micron tolerances, inserted
into two closed and known cross-sectional areas coupled
together to a reservoir, as shown in Fig. 7 .22.
• One of the cylinders is fitted with a close-fitting precision
piston with a top platform where accurately known weights,
In the form of discs can be loaded.
• The transducer under test is connected to the other
cylinder.
• The fluid pressure is then gradually applied until the force is
large enough to just lift the precision piston-weight
combination.
• When the piston is floating freely, the piston gauge with
arranged weights is in equilibrium with the pressure
developed in the cylinder.
• The relationship can be expressed as
F =PA , where F is the equivalent force of the
piston weight combination ( Total mass X acceleration due
to gravity)
P is the pressure and A is the area of the piston
cylinder combination.
• By changing the weights appropriately, the sensor can be
calibrated to a high order of accuracy.
• For high-precision measurements, the air weight testers
are preferred which offer an accuracy as high as 0.01 %.
FORCE-BALANCE TRANSDUCER :
• The performance of the transducers based on the measurement of
deflection of elastic elements, such as, diaphragms, membranes,
capsules or bellows is dependent on the long term stability
• characteristics of elastic elements, such as HYSTERESIS, CREEP degrade
the accuracy.
• For higher sensitivity, these elements must have low stiffness and/or
large area but the size of transducer becomes big and affected by
vibrations.
• Therefore the remedy is to go for Force balance transducer principle
which uses feed back principle
• In principle, force balance transducers employ
electrodynamic devices to balance the forces
produced by the elastic element which is subjected
to the pressure.
• force-balance system using electrodynamic force
balancing principle is shown in Fig. 7.12.
• Any pressure difference between inside and outside
of the bellows gives rise to a force F at the point A.
• The resultant displacement of the balancing beam is
detected by LVDT located at point B.
• The electrical output from the transducer is amplified causing
a current to flow through the balancing coil attached to the
beam.
• At the balance position, the electrodynamic force exerted by
the coil opposes the force exerted by the bellows.
• The current required to get such a balance is taken as a
measure of the unknown pressure p acting on the bellows.
• If the loop gain is large, an extremely small deflection of the
bellows is sufficient to activate the loop and achieved the
balance condition.
• Analysis of the closed loop feedback system in terms of the
transfer function can be very helpful .
Transduction Methods:
( pressure to electrical output)
• Electrical pressure transducers based on the principle of
variable capacitance , resistance, and inductance have
been developed for a variety of pressure measurements,
for converting the deflections or stresses developed in
elastic elements into corresponding electrical signals.
Potentiometric Device:
• The potentiometric-type pressure transducer is one of the
earliest type of electrical pressure sensors.
• In this, a diaphragm, capsule, bellows, or bourdon tube is linked
to a free-sliding wiper contact moving on a resistive element, as
shown in Fig. 7.4.
• The wiper is driven by the elastic element in response to the
applied pressure.
• Depending upon the design of the resistance element, the
output voltage can be made linear, or any other function of the
applied pressure.
Advantages :
1. High range,
2. Ruggedness,
3. Simple instrumentation.
Disadvantages :
1. Finite resolution
2. Limited life
3. Large size,
4. Poor frequency response,
5. Tendency to develop noise as slider wears off,
6. Susceptibility to vibration
Typical characteristics are
– Resolution is 0.2%
– Linearity of ± 1.0%.
– Repeatability of ± 0:25%,
– Hysteresis of ± 0.5%,
all with respect to F.S.R.
Strain Gauge Transducer :
• In the arrangement of a bonded strain gauge device is to fix the
strain gauges directly onto the diaphragm. The range of
application of this method is limited by the non-linearity of the
strain-pressure relationship above a certain strain value.
• For a clamped circular diaphragm of radius R, thickness
t, and pressure difference p, the maximum radial stress
at the edges is given by
• Frequency (and hence low sensitivity of acceleration) and good
dynamic response Since both tensile and compressive stresses
exist on the surface of the diaphragm.
• Strain gauges can be located as shown in the Fig. 7.5(a).
Gauges 1 and 3 bonded near the periphery respond to radial
strain, while 2 and 4 near the centre respond to tensile strain.
• This arrangement yields high sensitivity and fairly good
temperature stability
• The bridge circuit for this application is shown in Fig. 7.5(b)
provides output voltage corresponding to the pressure applied .
Variable Reluctance Sensor:
Pressure measurements can also be carried out using
variable inductance principle, where in the reluctance of a
magnetic path is changed in proportion to the pressure.
R= L / µA
• An extremely compact pressure transducer with a flat stretched
metal diaphragm is shown in Fig. 7.8
• An elastic ferromagnetic diaphragm D acting as an armature is
mounted symmetrically between the faces of two circular
ferromagnetic cores with a pressure port in each section.
• Two inductance coils are wound on the central section of each
core.
• The difference in pressure between the two sections causes the
diaphragm to deflect, resulting in a change in . the air gaps
between the core faces and the diaphragm.
• This leads to a change in the inductance of each coil.
• The coils are connected in the adjacent arms of an ac bridge
circuit, and the bridge output is proportional to the
magnitude of the differential pressure.
Unique feature is that ·
– The dynamic response is improved by the absence of any
mechanical linkage or any other form of loading on the
diaphragm.
– The sensitivity is high
– The device is ideally suited for very low pressure measurements.
– Rugged and insensitive to vibrations.
LVDT Type Transducer:
• One of the most popular types of pressure transducers is
the Linear Variable Differential Transformer type device in
which the LVDT is used as the sensing element.
• The elastic element, normally a diaphragm is coupled to
the core of the LVDT through a suitable mechanical
linkage, as illustrated in Fig 7.9.
• On application of pressure, the movement of the core as a
result of the diaphragm deflection is sensed precisely, and
the appropriate electrical output is interpreted in terms of
pressure values.
• However, the deflections have to be kept small for
obtaining reasonable linearity in a limited size.
• The dynamic response of this device is normally limited
because of the core mass .
Variable Capacitance device:
• For the measurement of very low pressure an equally suitable
device is the variable capacitance transducer.
• In this configuration a stretched metal diaphragm is positioned
symmetrically between the two stationary plates separating two
volumes as shown in Fig 7.10.
• The capacitance between these plates and the electrically grounded
diaphragm varies as a function of the deflection of the diaphragm,
which is proportional to the differential pressure applied.
• The changes in the two capacitances can be measured by an AC
bridge, or a tuned circuit.
piezoelectric pressure transducer:
• Certain types of materials generate an electrostatic charge or voltage when
mechanical stresses are applied across them.
• An opposite effect is also observed when an electrostatic charge or voltage
is applied to the crystal, resulting in the mechanical deformation of the
device.
• This property of piezoelectricity has been utilised in the design of pressure
transducers, wherein the mechanical stress is generated by the diaphragm
subjected-to pressure.
• The stress distribution in the crystal will depend not only on
• the load applied but also the manner in which this is applied, and upon the
size and shape of the sensing element.
• The important parameters considered are
1. Sensitivity,
2. Natural frequency,
3. Non-linearity,
4. Hysteresis,
5. Temperature effects,
6. Acceleration response, and
7. Cross sensitivity.
• The performance of a crystal element depends on
1. Magnitude of the crystal's piezoelectric constants.
2. Relative permittivity,
3. Natural time constant of the material,
4. Elastic constants, density, and the change of
piezoelectric constants with temperature
• The most popular ones having significant values or piezoelectric
constants and sensitivity are natural quartz, Rochelle salt, ADP and
a variety of synthetic ceramic materials like barium titanate and
lead-zirconatetitanate (Materials).
• Natural quartz is the most stable device for many applications. It
has a
1. Lower temperature sensitivity
2. Higher resistivity
3. Inherently long time constant which permits static calibration.
4. Exhibits good linearity over a wide range of stress levels with very
low hysteresis.
Thin Film Transducers:
Why?
Answer: Conventional pressure transducers is basically a measuring
cell divided by a diaphragm to which strain gauge are bonded. A change in
pressure will cause a negative or positive deflection of the diaphragm,
producing a measurable change in resistance within the strain gauge but
such devices are prone to
 Long term mechanical instability
 Especially at higher temperature
 Affected by vibration and hysteresis
These problems can be overcome by incorporating sputtered thin
film technology
Thin Film Pressure Transducer
• Is a standard pressure sensor, with changes in the diaphragm
configuration.
• Basic version has diffused single crystal chemically milled,
monocrystalline silicon diaphragm with the required strain gauge laid
down by diffusing boron on to the surface.
• Gauges are electrically isolated each other form the conductive
diaphragm and configured to form Wheatstone bridge network
• Later version of the transducer incorporate dielectrically isolated thin film
diaphragm on which the strain gauges are electro formed using sputter
vapour deposition techniques.
• The unwanted areas are removed by sputter etching using photoresist
techniques.
• The sensor is then positioned behind a metal diaphragm and the complete
assembly is mounted within a pressure tube as shown in figure
• Entire assembly is then mounted onto a metal pressure port with associated
components designed to compensate for any difference in the thermal
expansion.
Digital pressure transducer:
• With the advent of IC technology and advancement in microminiaturisation
innovation, it has become feasible to incorporate the signal conditioner and
associated electronic circuitry within the body of the transducer itself.
• This has now become almost a standard practice in the design of thin film
based and surface mounted devices, leading to the development of an
accurate digital pressure transducer with a number of intelligent signal
processing features housed within a relatively small volume.
• The various stages built-in are the
– Pre-amplifier
– Analog to digital converter
– An output processor, controlled with a microprocessor as
illustrated in the figure above
• The final electrical output can be directly connected to a digital display
or modified to give a direct output to 0 to + /- 5 V or 4 to 20 mA.
END of
Module 5
( Module-3 PART-B)
• Transducers/Instruments for Measurement of Level: Capacitance probes –
bare and coated capacitance probes, Conductivity probes, Float level devices –
atmospheric tanks, mercury float switch, pneumatic float switch, Optical level
switches-Noncontact level sensor, contacting level sensor, laser based level
detector, Ultrasonic level detector-On-ff and continuous, Thermal level sensors
Non-contacting optical level sensor.
THANK YOU
Module 4b)
1. With schematic block diagram explain electronic weighing system
2. Write short note on
a. Column types devices
b. Hydraulic l o a d c e l l
c. Absorption type
Module 5)
3. what is the importance of pressure measurement techniques. explain various elastic
elements with neat diagrams.
4. Describe the construction and working of following pressure transducers / sensors:
(i) LVDT type pressure transducers.
(ii) Potentiometer type pressure transducers
5. With a neat diagram explain the principle of working of capacitive transducer.
6. Explain the principle and working of different types of microphones used for the
measurement of noise.
7. with neat diagram and analysis explain force balance transducer
8. with neat diagram explain pressure multiplexer
9. with neat diagram explain standard dead weight tester for pressure calibration

More Related Content

Similar to Module_5_PPT_MHM.pptx

Pressure transduser, load cells , temperature compensation
Pressure transduser, load cells , temperature compensationPressure transduser, load cells , temperature compensation
Pressure transduser, load cells , temperature compensationPrasanthi Nelloor
 
Pressure measurement
Pressure measurement Pressure measurement
Pressure measurement
Uttam Trasadiya
 
Pressure measuring devices
Pressure measuring devicesPressure measuring devices
Pressure measuring devices
SALONI AGARWAL
 
Pressure sensor Measurement
Pressure  sensor Measurement Pressure  sensor Measurement
Pressure sensor Measurement
marcoReud
 
Transducers
TransducersTransducers
Transducers
Sachin Kumar
 
Pressure Measurement Instruments 1.pptx
Pressure Measurement Instruments 1.pptxPressure Measurement Instruments 1.pptx
Pressure Measurement Instruments 1.pptx
Hanif61
 
Basic Instrument Presentation ( pressure )
Basic Instrument Presentation ( pressure  ) Basic Instrument Presentation ( pressure  )
Basic Instrument Presentation ( pressure )
Aziz u rehman Jamali
 
Pressure Measurement Part III
Pressure Measurement   Part IIIPressure Measurement   Part III
Pressure Measurement Part III
Burdwan University
 
Lecture wk7 Strain Gauges.pdf
Lecture wk7 Strain Gauges.pdfLecture wk7 Strain Gauges.pdf
Lecture wk7 Strain Gauges.pdf
CHENDESHEN1
 
Ch6_Flow Measurements.pdf
Ch6_Flow Measurements.pdfCh6_Flow Measurements.pdf
Ch6_Flow Measurements.pdf
Vamshi962726
 
19IN Lec 3.pptx
19IN Lec 3.pptx19IN Lec 3.pptx
19IN Lec 3.pptx
faizanhaiderkhattak
 
In situ methods vane shear test
In  situ methods  vane shear testIn  situ methods  vane shear test
In situ methods vane shear test
bealberith
 
Strain gauge as pressure transducers
Strain gauge as pressure transducersStrain gauge as pressure transducers
Strain gauge as pressure transducers
karoline Enoch
 
Basics Of Instrumentation
Basics Of InstrumentationBasics Of Instrumentation
Basics Of Instrumentation
Vinoth Ganesh
 
instrumentation measurement actvitvities
instrumentation measurement actvitvitiesinstrumentation measurement actvitvities
instrumentation measurement actvitvities
chilinks4all1
 
Pressure measurement wiki lesker pumping 3_6_09 (2)
Pressure measurement wiki lesker pumping 3_6_09 (2)Pressure measurement wiki lesker pumping 3_6_09 (2)
Pressure measurement wiki lesker pumping 3_6_09 (2)
shivanand swami
 
Diaphragm and bellows pressure gauge
Diaphragm  and bellows pressure gaugeDiaphragm  and bellows pressure gauge
Diaphragm and bellows pressure gauge
KrishnaKantNayak2
 
Strain gauge
Strain gaugeStrain gauge
Strain gauge
ssuser4adfee
 
Strength of materials_laboratory
Strength of materials_laboratoryStrength of materials_laboratory
Strength of materials_laboratory
sudheerchekka1
 

Similar to Module_5_PPT_MHM.pptx (20)

Pressure transduser, load cells , temperature compensation
Pressure transduser, load cells , temperature compensationPressure transduser, load cells , temperature compensation
Pressure transduser, load cells , temperature compensation
 
Pressure measurement
Pressure measurement Pressure measurement
Pressure measurement
 
Pressure measuring devices
Pressure measuring devicesPressure measuring devices
Pressure measuring devices
 
Pressure sensor Measurement
Pressure  sensor Measurement Pressure  sensor Measurement
Pressure sensor Measurement
 
Transducers
TransducersTransducers
Transducers
 
Pressure Measurement Instruments 1.pptx
Pressure Measurement Instruments 1.pptxPressure Measurement Instruments 1.pptx
Pressure Measurement Instruments 1.pptx
 
Basic Instrument Presentation ( pressure )
Basic Instrument Presentation ( pressure  ) Basic Instrument Presentation ( pressure  )
Basic Instrument Presentation ( pressure )
 
Pressure Measurement Part III
Pressure Measurement   Part IIIPressure Measurement   Part III
Pressure Measurement Part III
 
Lecture wk7 Strain Gauges.pdf
Lecture wk7 Strain Gauges.pdfLecture wk7 Strain Gauges.pdf
Lecture wk7 Strain Gauges.pdf
 
Ch6_Flow Measurements.pdf
Ch6_Flow Measurements.pdfCh6_Flow Measurements.pdf
Ch6_Flow Measurements.pdf
 
19IN Lec 3.pptx
19IN Lec 3.pptx19IN Lec 3.pptx
19IN Lec 3.pptx
 
In situ methods vane shear test
In  situ methods  vane shear testIn  situ methods  vane shear test
In situ methods vane shear test
 
Strain gauge as pressure transducers
Strain gauge as pressure transducersStrain gauge as pressure transducers
Strain gauge as pressure transducers
 
Basics Of Instrumentation
Basics Of InstrumentationBasics Of Instrumentation
Basics Of Instrumentation
 
instrumentation measurement actvitvities
instrumentation measurement actvitvitiesinstrumentation measurement actvitvities
instrumentation measurement actvitvities
 
strain gauges
strain gauges strain gauges
strain gauges
 
Pressure measurement wiki lesker pumping 3_6_09 (2)
Pressure measurement wiki lesker pumping 3_6_09 (2)Pressure measurement wiki lesker pumping 3_6_09 (2)
Pressure measurement wiki lesker pumping 3_6_09 (2)
 
Diaphragm and bellows pressure gauge
Diaphragm  and bellows pressure gaugeDiaphragm  and bellows pressure gauge
Diaphragm and bellows pressure gauge
 
Strain gauge
Strain gaugeStrain gauge
Strain gauge
 
Strength of materials_laboratory
Strength of materials_laboratoryStrength of materials_laboratory
Strength of materials_laboratory
 

Recently uploaded

Cosmetic shop management system project report.pdf
Cosmetic shop management system project report.pdfCosmetic shop management system project report.pdf
Cosmetic shop management system project report.pdf
Kamal Acharya
 
ASME IX(9) 2007 Full Version .pdf
ASME IX(9)  2007 Full Version       .pdfASME IX(9)  2007 Full Version       .pdf
ASME IX(9) 2007 Full Version .pdf
AhmedHussein950959
 
Investor-Presentation-Q1FY2024 investor presentation document.pptx
Investor-Presentation-Q1FY2024 investor presentation document.pptxInvestor-Presentation-Q1FY2024 investor presentation document.pptx
Investor-Presentation-Q1FY2024 investor presentation document.pptx
AmarGB2
 
Pile Foundation by Venkatesh Taduvai (Sub Geotechnical Engineering II)-conver...
Pile Foundation by Venkatesh Taduvai (Sub Geotechnical Engineering II)-conver...Pile Foundation by Venkatesh Taduvai (Sub Geotechnical Engineering II)-conver...
Pile Foundation by Venkatesh Taduvai (Sub Geotechnical Engineering II)-conver...
AJAYKUMARPUND1
 
Student information management system project report ii.pdf
Student information management system project report ii.pdfStudent information management system project report ii.pdf
Student information management system project report ii.pdf
Kamal Acharya
 
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
MdTanvirMahtab2
 
Immunizing Image Classifiers Against Localized Adversary Attacks
Immunizing Image Classifiers Against Localized Adversary AttacksImmunizing Image Classifiers Against Localized Adversary Attacks
Immunizing Image Classifiers Against Localized Adversary Attacks
gerogepatton
 
Railway Signalling Principles Edition 3.pdf
Railway Signalling Principles Edition 3.pdfRailway Signalling Principles Edition 3.pdf
Railway Signalling Principles Edition 3.pdf
TeeVichai
 
Architectural Portfolio Sean Lockwood
Architectural Portfolio Sean LockwoodArchitectural Portfolio Sean Lockwood
Architectural Portfolio Sean Lockwood
seandesed
 
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdfHybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
fxintegritypublishin
 
CME397 Surface Engineering- Professional Elective
CME397 Surface Engineering- Professional ElectiveCME397 Surface Engineering- Professional Elective
CME397 Surface Engineering- Professional Elective
karthi keyan
 
block diagram and signal flow graph representation
block diagram and signal flow graph representationblock diagram and signal flow graph representation
block diagram and signal flow graph representation
Divya Somashekar
 
ethical hacking-mobile hacking methods.ppt
ethical hacking-mobile hacking methods.pptethical hacking-mobile hacking methods.ppt
ethical hacking-mobile hacking methods.ppt
Jayaprasanna4
 
Fundamentals of Electric Drives and its applications.pptx
Fundamentals of Electric Drives and its applications.pptxFundamentals of Electric Drives and its applications.pptx
Fundamentals of Electric Drives and its applications.pptx
manasideore6
 
Planning Of Procurement o different goods and services
Planning Of Procurement o different goods and servicesPlanning Of Procurement o different goods and services
Planning Of Procurement o different goods and services
JoytuBarua2
 
road safety engineering r s e unit 3.pdf
road safety engineering  r s e unit 3.pdfroad safety engineering  r s e unit 3.pdf
road safety engineering r s e unit 3.pdf
VENKATESHvenky89705
 
ethical hacking in wireless-hacking1.ppt
ethical hacking in wireless-hacking1.pptethical hacking in wireless-hacking1.ppt
ethical hacking in wireless-hacking1.ppt
Jayaprasanna4
 
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
Amil Baba Dawood bangali
 
Nuclear Power Economics and Structuring 2024
Nuclear Power Economics and Structuring 2024Nuclear Power Economics and Structuring 2024
Nuclear Power Economics and Structuring 2024
Massimo Talia
 
Hierarchical Digital Twin of a Naval Power System
Hierarchical Digital Twin of a Naval Power SystemHierarchical Digital Twin of a Naval Power System
Hierarchical Digital Twin of a Naval Power System
Kerry Sado
 

Recently uploaded (20)

Cosmetic shop management system project report.pdf
Cosmetic shop management system project report.pdfCosmetic shop management system project report.pdf
Cosmetic shop management system project report.pdf
 
ASME IX(9) 2007 Full Version .pdf
ASME IX(9)  2007 Full Version       .pdfASME IX(9)  2007 Full Version       .pdf
ASME IX(9) 2007 Full Version .pdf
 
Investor-Presentation-Q1FY2024 investor presentation document.pptx
Investor-Presentation-Q1FY2024 investor presentation document.pptxInvestor-Presentation-Q1FY2024 investor presentation document.pptx
Investor-Presentation-Q1FY2024 investor presentation document.pptx
 
Pile Foundation by Venkatesh Taduvai (Sub Geotechnical Engineering II)-conver...
Pile Foundation by Venkatesh Taduvai (Sub Geotechnical Engineering II)-conver...Pile Foundation by Venkatesh Taduvai (Sub Geotechnical Engineering II)-conver...
Pile Foundation by Venkatesh Taduvai (Sub Geotechnical Engineering II)-conver...
 
Student information management system project report ii.pdf
Student information management system project report ii.pdfStudent information management system project report ii.pdf
Student information management system project report ii.pdf
 
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
 
Immunizing Image Classifiers Against Localized Adversary Attacks
Immunizing Image Classifiers Against Localized Adversary AttacksImmunizing Image Classifiers Against Localized Adversary Attacks
Immunizing Image Classifiers Against Localized Adversary Attacks
 
Railway Signalling Principles Edition 3.pdf
Railway Signalling Principles Edition 3.pdfRailway Signalling Principles Edition 3.pdf
Railway Signalling Principles Edition 3.pdf
 
Architectural Portfolio Sean Lockwood
Architectural Portfolio Sean LockwoodArchitectural Portfolio Sean Lockwood
Architectural Portfolio Sean Lockwood
 
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdfHybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
 
CME397 Surface Engineering- Professional Elective
CME397 Surface Engineering- Professional ElectiveCME397 Surface Engineering- Professional Elective
CME397 Surface Engineering- Professional Elective
 
block diagram and signal flow graph representation
block diagram and signal flow graph representationblock diagram and signal flow graph representation
block diagram and signal flow graph representation
 
ethical hacking-mobile hacking methods.ppt
ethical hacking-mobile hacking methods.pptethical hacking-mobile hacking methods.ppt
ethical hacking-mobile hacking methods.ppt
 
Fundamentals of Electric Drives and its applications.pptx
Fundamentals of Electric Drives and its applications.pptxFundamentals of Electric Drives and its applications.pptx
Fundamentals of Electric Drives and its applications.pptx
 
Planning Of Procurement o different goods and services
Planning Of Procurement o different goods and servicesPlanning Of Procurement o different goods and services
Planning Of Procurement o different goods and services
 
road safety engineering r s e unit 3.pdf
road safety engineering  r s e unit 3.pdfroad safety engineering  r s e unit 3.pdf
road safety engineering r s e unit 3.pdf
 
ethical hacking in wireless-hacking1.ppt
ethical hacking in wireless-hacking1.pptethical hacking in wireless-hacking1.ppt
ethical hacking in wireless-hacking1.ppt
 
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
 
Nuclear Power Economics and Structuring 2024
Nuclear Power Economics and Structuring 2024Nuclear Power Economics and Structuring 2024
Nuclear Power Economics and Structuring 2024
 
Hierarchical Digital Twin of a Naval Power System
Hierarchical Digital Twin of a Naval Power SystemHierarchical Digital Twin of a Naval Power System
Hierarchical Digital Twin of a Naval Power System
 

Module_5_PPT_MHM.pptx

  • 1. MEASUREMENT OF PRESSURE Module -5 Measurement of Pressure: • Introduction, • Diaphragms, Other elastic elements, • Transduction methods – • Potentiometric device, • Strain gauge transducer , • Variable reluctance, • LVDT type, • Variable capacitance device (principle & working, no derivation), • Force balance transducer with analysis, • Thin-film pressure transducers, • Piezoelectric pressure transducer, • Pressure multiplexer, • Pressure calibration.
  • 2. Module -5 Transducers/Instruments for Measurement of Pressure: Introduction, Diaphragms, Other elastic elements, Transduction methods – potentiometric device, strain gauge transducer, variable reluctance, LVDT type, variable capacitance device (principle & working, no derivation), force balance transducer with analysis, Thin film pressure transducers, Digital pressure transducer, Piezoelectric pressure transducer, Pressure multiplexer, Pressure calibration.
  • 3. Pressure : ( 1 atmospheric pressure =14.7 Psi ) • Force acting per unit area N/m2 • Measurement involved can be static or dynamic. • Pressure is a compressive stress exerted uniformly in all directions (considering fluid (can be liquid or Gas) pressure) • Pressure transducers can be classified as 1. Gravitational type ( Manometer is the simplest device) 2. Elastic type ( Pressure exert force over area of elastic device example : Diaphragm , Capsule, Bellows, Bourdon tube ) • With respect to applied pressure Elastic device output is displacement or strain developed and it is measured by electrical sensor
  • 4. • The transduction principles (involves) displacement measurements with resistive (strain gauge), inductive, and capacitive principles or measurement of change in natural resonance frequency of a stretched member. • Accordingly they are classified as potentiometric, bonded and unbonded strain gauge, piezoresistive, inductive, LVDT, capacitive, piezoelectric types. DIAPHRAGMS : (Materials used Elastomers and polyamide, polyester, polyacrylamide, and rayon staple fiber fabrics) • Common pressure sensing member • Consists of a circular plate & fastened (connected) at its periphery. • Structure can be flat or corrugated. • Used when high Accuracy required and provide good dynamic response.
  • 5.
  • 6. • Main characteristics of diaphragms are 1. Ruggedness 2. Stability 3. Reliability 4. Low Hysteresis 5. Low creep 6. Good dynamic response • Diaphragms are made from 1. Metal alloys 2. Bronze 3. Phosphor bronze 4. Stainless steel
  • 7. Diagram shown below is not for exam
  • 8. • Flat diaphragms can be designed to have high natural frequencies and as such are ideally suited for dynamic measurements. • Due to imperfections in the material and in the manufacturing process, the Pressure deflection curve can have certain nonlinear characteristics and other errors, such as hysteresis. • To avoid this, the diaphragm is usually stretched radially and then clamped. • Deflections of the diaphragm of small magnitude. are mainly due to bending deformations only.
  • 9. • With increased load on the diaphragm, when the deflection reaches the value roughly equal to its thickness, tensile stresses also develop along with bending and the deflection characteristics become non-linear. • For larger deflection requirements, corrugated diaphragms are ideally suited. Corrugated Diaphragms: • corrugated diaphragms are also encountered in pressure measurements, especially where larger deflections are required than those normally obtained with flat diaphragms. • Diaphragm profiles take different forms, such as sawtooth. trapezoidal, and sinusoidal shapes, as shown in Fig. 7.3
  • 10.
  • 11. Capsule : • A capsule consists of two identical annular corrugated metal diaphragms sealed together at the periphery to obtain a shell like enclosure. • One of the diaphragms is provided with a central reinforced port to admit the pressure to be measured, and the other is linked to a mechanical member. • The displacement of this ,member is proportional to the difference of the inner and outer pressures. • The seal is made by brazing, soldering, or electron-beam welding, and the whole capsule is heat treated to relieve the stresses built up during welding and subsequent cooling. • The factors influencing the deflections of the capsule are the same as those for the diaphragms.
  • 12. Bourdon Tube: • The bourdon tube is a curved or twisted metallic tube having an elliptical cross-section, and scaled at one end. • The tube tends to straighten out on the application of pressure, and the angular deflection of the free end is taken as a measure of the pressure. • The deflection sensitivity is a function of the aspect ratio of the tube cross-section. • The main advantages are high sensitivity and good repeatability.
  • 13. • The C-shaped tube has a total angle of curvature of 180 to 270°, and the angular Deflection (output) is normally measured with a mechanical pointer moving over a calibrated scale or with a potentiometric or L VDT transducer. • The deflection of a bourdon tube varies • With the ratio of its major to minor cross-sectional axis, • Tube length, • Difference between the internal and external pressures, • Radius of curvature, and • Angle of twist. • It also varies inversely with the tube wall thickness and the modulus of elasticity of the material used.
  • 14. • The angular deflection of the helical-type and C-type bourdon tubes can be expressed by the equation. Where Ø = angle of rotation of the tip of the tube. Ø0 = angle of tube/total angle of helix P = pressure in pascals r = radius of the tube/helix in meters t = wall thickness in meters E = Young's modulus of material b = minor axis of the tube, measured from the middle of one wall to the middle of the other wall, in meters.
  • 15. PRESSURE MULTIPLEXER : Problem ? • In certain experiments, such as wind-tunnel testing of models, a simultaneous measurement of pressures at various locations is required for detailed investigations. • If a pressure transducer is individually used at each pressure point, the entire equipment tends to be large, expensive, and cumbersome, since each sensor needs a separate balance control, zero control and signal conditioner. ANS : Hence for simultaneous measurement of pressure at various location pressure multiplexer is used
  • 16.
  • 17. • However, by incorporating a pressure-transfer valve, the. pressures at a large number of points can be measured with a single transducer. A typical pressure multiplexer system using a scanivalve arrangement is illustrated in Fig. 7.21. • The scanivalve with 24 or 48 ports is driven either by a motor or solenoid, and connects a small unbonded strain gauge type pressure transducer to the pressure ports sequentially, one at a time.
  • 18. • The signal from the transducer is processed with a suitable signal conditioner and converted equivalent value that is analog / digital printed out or displayed in required units. • The transducer is housed within the body of the valve itself to keep the transfer volume minimum, thereby ensuring good response even at low pressure levels. • The maximum speed of sampling can be as high as 48 ports per minute.
  • 19. • In some experiments it may be necessary to freeze several unknown pressure values simultaneously and then measure the pressure magnitudes later for this, cut-off valves with storage tubes are incorporated ahead. of the pressure multiplexer. • The system is extensively used for many aeronautical and allied measurements.
  • 20. PRESSURE CALIBRATION: ( pressure gauge calibration) • A basic standard calibrating device widely used under laboratory conditions is the hydraulic or pneumatically-operated dead weight tester. • Range is from 50 to 50x 106 Pascal's in steps of 0.1% with an uncertainty of 0.01 to 0.5%. • The dead-weight tester consists of two accurately machined cylinders, honed to micron tolerances, inserted into two closed and known cross-sectional areas coupled together to a reservoir, as shown in Fig. 7 .22.
  • 21.
  • 22. • One of the cylinders is fitted with a close-fitting precision piston with a top platform where accurately known weights, In the form of discs can be loaded. • The transducer under test is connected to the other cylinder. • The fluid pressure is then gradually applied until the force is large enough to just lift the precision piston-weight combination. • When the piston is floating freely, the piston gauge with arranged weights is in equilibrium with the pressure developed in the cylinder.
  • 23. • The relationship can be expressed as F =PA , where F is the equivalent force of the piston weight combination ( Total mass X acceleration due to gravity) P is the pressure and A is the area of the piston cylinder combination. • By changing the weights appropriately, the sensor can be calibrated to a high order of accuracy. • For high-precision measurements, the air weight testers are preferred which offer an accuracy as high as 0.01 %.
  • 24. FORCE-BALANCE TRANSDUCER : • The performance of the transducers based on the measurement of deflection of elastic elements, such as, diaphragms, membranes, capsules or bellows is dependent on the long term stability • characteristics of elastic elements, such as HYSTERESIS, CREEP degrade the accuracy. • For higher sensitivity, these elements must have low stiffness and/or large area but the size of transducer becomes big and affected by vibrations. • Therefore the remedy is to go for Force balance transducer principle which uses feed back principle
  • 25.
  • 26. • In principle, force balance transducers employ electrodynamic devices to balance the forces produced by the elastic element which is subjected to the pressure. • force-balance system using electrodynamic force balancing principle is shown in Fig. 7.12. • Any pressure difference between inside and outside of the bellows gives rise to a force F at the point A. • The resultant displacement of the balancing beam is detected by LVDT located at point B.
  • 27. • The electrical output from the transducer is amplified causing a current to flow through the balancing coil attached to the beam. • At the balance position, the electrodynamic force exerted by the coil opposes the force exerted by the bellows. • The current required to get such a balance is taken as a measure of the unknown pressure p acting on the bellows. • If the loop gain is large, an extremely small deflection of the bellows is sufficient to activate the loop and achieved the balance condition. • Analysis of the closed loop feedback system in terms of the transfer function can be very helpful .
  • 28.
  • 29.
  • 30.
  • 31.
  • 32. Transduction Methods: ( pressure to electrical output) • Electrical pressure transducers based on the principle of variable capacitance , resistance, and inductance have been developed for a variety of pressure measurements, for converting the deflections or stresses developed in elastic elements into corresponding electrical signals.
  • 34. • The potentiometric-type pressure transducer is one of the earliest type of electrical pressure sensors. • In this, a diaphragm, capsule, bellows, or bourdon tube is linked to a free-sliding wiper contact moving on a resistive element, as shown in Fig. 7.4. • The wiper is driven by the elastic element in response to the applied pressure. • Depending upon the design of the resistance element, the output voltage can be made linear, or any other function of the applied pressure.
  • 35. Advantages : 1. High range, 2. Ruggedness, 3. Simple instrumentation. Disadvantages : 1. Finite resolution 2. Limited life 3. Large size, 4. Poor frequency response, 5. Tendency to develop noise as slider wears off, 6. Susceptibility to vibration Typical characteristics are – Resolution is 0.2% – Linearity of ± 1.0%. – Repeatability of ± 0:25%, – Hysteresis of ± 0.5%, all with respect to F.S.R.
  • 36. Strain Gauge Transducer : • In the arrangement of a bonded strain gauge device is to fix the strain gauges directly onto the diaphragm. The range of application of this method is limited by the non-linearity of the strain-pressure relationship above a certain strain value.
  • 37. • For a clamped circular diaphragm of radius R, thickness t, and pressure difference p, the maximum radial stress at the edges is given by
  • 38. • Frequency (and hence low sensitivity of acceleration) and good dynamic response Since both tensile and compressive stresses exist on the surface of the diaphragm. • Strain gauges can be located as shown in the Fig. 7.5(a). Gauges 1 and 3 bonded near the periphery respond to radial strain, while 2 and 4 near the centre respond to tensile strain. • This arrangement yields high sensitivity and fairly good temperature stability • The bridge circuit for this application is shown in Fig. 7.5(b) provides output voltage corresponding to the pressure applied .
  • 39. Variable Reluctance Sensor: Pressure measurements can also be carried out using variable inductance principle, where in the reluctance of a magnetic path is changed in proportion to the pressure. R= L / µA
  • 40. • An extremely compact pressure transducer with a flat stretched metal diaphragm is shown in Fig. 7.8 • An elastic ferromagnetic diaphragm D acting as an armature is mounted symmetrically between the faces of two circular ferromagnetic cores with a pressure port in each section. • Two inductance coils are wound on the central section of each core. • The difference in pressure between the two sections causes the diaphragm to deflect, resulting in a change in . the air gaps between the core faces and the diaphragm.
  • 41. • This leads to a change in the inductance of each coil. • The coils are connected in the adjacent arms of an ac bridge circuit, and the bridge output is proportional to the magnitude of the differential pressure. Unique feature is that · – The dynamic response is improved by the absence of any mechanical linkage or any other form of loading on the diaphragm. – The sensitivity is high – The device is ideally suited for very low pressure measurements. – Rugged and insensitive to vibrations.
  • 43. • One of the most popular types of pressure transducers is the Linear Variable Differential Transformer type device in which the LVDT is used as the sensing element. • The elastic element, normally a diaphragm is coupled to the core of the LVDT through a suitable mechanical linkage, as illustrated in Fig 7.9. • On application of pressure, the movement of the core as a result of the diaphragm deflection is sensed precisely, and the appropriate electrical output is interpreted in terms of pressure values. • However, the deflections have to be kept small for obtaining reasonable linearity in a limited size. • The dynamic response of this device is normally limited because of the core mass .
  • 45. • For the measurement of very low pressure an equally suitable device is the variable capacitance transducer. • In this configuration a stretched metal diaphragm is positioned symmetrically between the two stationary plates separating two volumes as shown in Fig 7.10. • The capacitance between these plates and the electrically grounded diaphragm varies as a function of the deflection of the diaphragm, which is proportional to the differential pressure applied. • The changes in the two capacitances can be measured by an AC bridge, or a tuned circuit.
  • 46. piezoelectric pressure transducer: • Certain types of materials generate an electrostatic charge or voltage when mechanical stresses are applied across them. • An opposite effect is also observed when an electrostatic charge or voltage is applied to the crystal, resulting in the mechanical deformation of the device. • This property of piezoelectricity has been utilised in the design of pressure transducers, wherein the mechanical stress is generated by the diaphragm subjected-to pressure. • The stress distribution in the crystal will depend not only on • the load applied but also the manner in which this is applied, and upon the size and shape of the sensing element.
  • 47. • The important parameters considered are 1. Sensitivity, 2. Natural frequency, 3. Non-linearity, 4. Hysteresis, 5. Temperature effects, 6. Acceleration response, and 7. Cross sensitivity. • The performance of a crystal element depends on 1. Magnitude of the crystal's piezoelectric constants. 2. Relative permittivity, 3. Natural time constant of the material, 4. Elastic constants, density, and the change of piezoelectric constants with temperature
  • 48. • The most popular ones having significant values or piezoelectric constants and sensitivity are natural quartz, Rochelle salt, ADP and a variety of synthetic ceramic materials like barium titanate and lead-zirconatetitanate (Materials). • Natural quartz is the most stable device for many applications. It has a 1. Lower temperature sensitivity 2. Higher resistivity 3. Inherently long time constant which permits static calibration. 4. Exhibits good linearity over a wide range of stress levels with very low hysteresis.
  • 49.
  • 50. Thin Film Transducers: Why? Answer: Conventional pressure transducers is basically a measuring cell divided by a diaphragm to which strain gauge are bonded. A change in pressure will cause a negative or positive deflection of the diaphragm, producing a measurable change in resistance within the strain gauge but such devices are prone to  Long term mechanical instability  Especially at higher temperature  Affected by vibration and hysteresis These problems can be overcome by incorporating sputtered thin film technology
  • 51. Thin Film Pressure Transducer • Is a standard pressure sensor, with changes in the diaphragm configuration. • Basic version has diffused single crystal chemically milled, monocrystalline silicon diaphragm with the required strain gauge laid down by diffusing boron on to the surface. • Gauges are electrically isolated each other form the conductive diaphragm and configured to form Wheatstone bridge network
  • 52.
  • 53. • Later version of the transducer incorporate dielectrically isolated thin film diaphragm on which the strain gauges are electro formed using sputter vapour deposition techniques. • The unwanted areas are removed by sputter etching using photoresist techniques. • The sensor is then positioned behind a metal diaphragm and the complete assembly is mounted within a pressure tube as shown in figure • Entire assembly is then mounted onto a metal pressure port with associated components designed to compensate for any difference in the thermal expansion.
  • 54. Digital pressure transducer: • With the advent of IC technology and advancement in microminiaturisation innovation, it has become feasible to incorporate the signal conditioner and associated electronic circuitry within the body of the transducer itself. • This has now become almost a standard practice in the design of thin film based and surface mounted devices, leading to the development of an accurate digital pressure transducer with a number of intelligent signal processing features housed within a relatively small volume.
  • 55.
  • 56. • The various stages built-in are the – Pre-amplifier – Analog to digital converter – An output processor, controlled with a microprocessor as illustrated in the figure above • The final electrical output can be directly connected to a digital display or modified to give a direct output to 0 to + /- 5 V or 4 to 20 mA.
  • 58. ( Module-3 PART-B) • Transducers/Instruments for Measurement of Level: Capacitance probes – bare and coated capacitance probes, Conductivity probes, Float level devices – atmospheric tanks, mercury float switch, pneumatic float switch, Optical level switches-Noncontact level sensor, contacting level sensor, laser based level detector, Ultrasonic level detector-On-ff and continuous, Thermal level sensors
  • 59.
  • 60.
  • 61.
  • 62.
  • 63.
  • 64.
  • 66.
  • 67.
  • 68.
  • 69.
  • 70.
  • 71.
  • 72.
  • 73.
  • 75. Module 4b) 1. With schematic block diagram explain electronic weighing system 2. Write short note on a. Column types devices b. Hydraulic l o a d c e l l c. Absorption type Module 5) 3. what is the importance of pressure measurement techniques. explain various elastic elements with neat diagrams. 4. Describe the construction and working of following pressure transducers / sensors: (i) LVDT type pressure transducers. (ii) Potentiometer type pressure transducers 5. With a neat diagram explain the principle of working of capacitive transducer. 6. Explain the principle and working of different types of microphones used for the measurement of noise. 7. with neat diagram and analysis explain force balance transducer 8. with neat diagram explain pressure multiplexer 9. with neat diagram explain standard dead weight tester for pressure calibration