Bacharach Informant 2
Refrigerant Leak Detector
The Informant 2 allows pinpoint detection of
both refrigerant and combustible gas leaks with
one instrument
Fast Warm-up, Fast Response

KEYBENEFITS

The unique combination of state-of-the-art patented sensor

• Sequential flashing probe tip, dual 	

technology, advanced software design and microprocessor-controlled

	

circuitry offers unmatched precision coupled with tremendous speed

LED displays and loud tick rate

Swaps sensor tips within seconds and leaves the user free of worry

indicates relative concentration levels

about adjusting sensitivity levels - it’s taken care of automatically

	

	

tight areas

• Sensor set at the tip for pinpoint 	

The diameter of the tip of the sensor is 0.2” allowing the user to get

	

accuracy and instantaneous response 	
time

Access Hard to Reach Areas
between coils and fitting, gaining access to the tighter spots.

Audible Indication
The audible indication of the Informant 2 features a mute option
coupled with sequential LED’s to monitor increasing concentrations.

Gases

HFC

“

HCFC

CFC

Combustible

One instrument – two functions.
Quickly interchange the sensor
to suit your application

“

• Utilises long probe to reach into
TECHNICALSPECIFICATION

ALARM SENSITIVITY

• Refrigerant: Less than 0.25 oz/year of R134a
• Combustibles: Minimum 50 PPM (Methane)

WEIGHT & DIMENSIONS

• 1.75” (W) x 9.62” (L) x 2.25” (H)

POWER

4.45 cm x 24.43 cm x 5.72 cm

• Power Source: Four AA disposable alkaline batteries
• Warm-up Time: 10 seconds
• Response Time: Instantaneous
• Battery life: 4-5 hours, under typical intermittent

• Fully extended probe: 20” (50.8 cm)
Coiled probe: 3” (7.62 cm)

• Weight: 0.86 lbs. (0.39 kg) with batteries
SENSING ELEMENTS

• Refrigerant: Heated Diode – U.S. Patent No. 5,932,176
• Combustible: Patented semiconductor type. Five year

operation

APPROVALS

	

• Refrigerant: UL listed in accordance with SAE J1627
• Combustible: MET Lab certified to UL 913, intrinsically

typical life.

GASES DETECTED

	

safe for use in Class I, Division 1, Group D hazardous 	

• All CFC, HCFC and HFC refrigerants including: R-12, R-22,

	

areas.

R-123, R-134a and blends R-404A, R-408A, R-409A and
R-410A (i.e., any refrigerant containing Chlorine, Fluorine 	

WARRANTY

or Bromine gas)

• One year, including sensor

• All combustible gases and vapors

ORDERINGINFORMATION

• Instrument comes with refrigerant and combustible gas 	
sensors, colour-coded sensor tips, protective rubber boot,

Part Number -19-8038
Informant 2 Contractor Kit

flashlight, instruction manual, 6AA batteries and 5 filters 	

• Instrument comes with refrigerant and combustible gas

all packaged in a hard carrying case

sensors, colour-coded sensor tips, instruction manual, 4 	

	

AA batteries and a hard carrying case.

Part Number -19-8042
Dual Informant 2 Detector Kit

• Instrument comes with refrigerant and combustible gas 	
sensors, colour-coded sensor tips, instruction manual, 	
4AA batteries, 5 filters and a custom soft carrying case

Part Number -19-8045
Dual Deluxe Informant 2 Detector Kit

Part Number -19-8040
Refrigerant Only Informant 2 Detector Kit

• Instrument comes with refrigerant sensor, colour-coded

probe tip, instruction manual, 4AA batteries, 5 filters and a	
custom carry case

Part Number -19-8040
Combustible Gas Upgrade Kit

• To upgrade a refrigerant only. Informant 2 to a dual
sensing instrument. Includes combustible gas sensor, 	
colour-coded probe tip and 5 filters

11 Ark Royal, Lairdside Technology Park, Tranmere, Wirral, CH41 9HT
T: +44(0)151 666 8300 F: +44(0)151 666 8329 E: sales@a1-cbiss.com
W: www.a1-cbiss.com Buy Online: shop.a1-cbiss.com

Cert No. 996
ISO 9001

Informant 2 datasheet 0

  • 1.
    Bacharach Informant 2 RefrigerantLeak Detector The Informant 2 allows pinpoint detection of both refrigerant and combustible gas leaks with one instrument Fast Warm-up, Fast Response KEYBENEFITS The unique combination of state-of-the-art patented sensor • Sequential flashing probe tip, dual technology, advanced software design and microprocessor-controlled circuitry offers unmatched precision coupled with tremendous speed LED displays and loud tick rate Swaps sensor tips within seconds and leaves the user free of worry indicates relative concentration levels about adjusting sensitivity levels - it’s taken care of automatically tight areas • Sensor set at the tip for pinpoint The diameter of the tip of the sensor is 0.2” allowing the user to get accuracy and instantaneous response time Access Hard to Reach Areas between coils and fitting, gaining access to the tighter spots. Audible Indication The audible indication of the Informant 2 features a mute option coupled with sequential LED’s to monitor increasing concentrations. Gases HFC “ HCFC CFC Combustible One instrument – two functions. Quickly interchange the sensor to suit your application “ • Utilises long probe to reach into
  • 2.
    TECHNICALSPECIFICATION ALARM SENSITIVITY • Refrigerant:Less than 0.25 oz/year of R134a • Combustibles: Minimum 50 PPM (Methane) WEIGHT & DIMENSIONS • 1.75” (W) x 9.62” (L) x 2.25” (H) POWER 4.45 cm x 24.43 cm x 5.72 cm • Power Source: Four AA disposable alkaline batteries • Warm-up Time: 10 seconds • Response Time: Instantaneous • Battery life: 4-5 hours, under typical intermittent • Fully extended probe: 20” (50.8 cm) Coiled probe: 3” (7.62 cm) • Weight: 0.86 lbs. (0.39 kg) with batteries SENSING ELEMENTS • Refrigerant: Heated Diode – U.S. Patent No. 5,932,176 • Combustible: Patented semiconductor type. Five year operation APPROVALS • Refrigerant: UL listed in accordance with SAE J1627 • Combustible: MET Lab certified to UL 913, intrinsically typical life. GASES DETECTED safe for use in Class I, Division 1, Group D hazardous • All CFC, HCFC and HFC refrigerants including: R-12, R-22, areas. R-123, R-134a and blends R-404A, R-408A, R-409A and R-410A (i.e., any refrigerant containing Chlorine, Fluorine WARRANTY or Bromine gas) • One year, including sensor • All combustible gases and vapors ORDERINGINFORMATION • Instrument comes with refrigerant and combustible gas sensors, colour-coded sensor tips, protective rubber boot, Part Number -19-8038 Informant 2 Contractor Kit flashlight, instruction manual, 6AA batteries and 5 filters • Instrument comes with refrigerant and combustible gas all packaged in a hard carrying case sensors, colour-coded sensor tips, instruction manual, 4 AA batteries and a hard carrying case. Part Number -19-8042 Dual Informant 2 Detector Kit • Instrument comes with refrigerant and combustible gas sensors, colour-coded sensor tips, instruction manual, 4AA batteries, 5 filters and a custom soft carrying case Part Number -19-8045 Dual Deluxe Informant 2 Detector Kit Part Number -19-8040 Refrigerant Only Informant 2 Detector Kit • Instrument comes with refrigerant sensor, colour-coded probe tip, instruction manual, 4AA batteries, 5 filters and a custom carry case Part Number -19-8040 Combustible Gas Upgrade Kit • To upgrade a refrigerant only. Informant 2 to a dual sensing instrument. Includes combustible gas sensor, colour-coded probe tip and 5 filters 11 Ark Royal, Lairdside Technology Park, Tranmere, Wirral, CH41 9HT T: +44(0)151 666 8300 F: +44(0)151 666 8329 E: sales@a1-cbiss.com W: www.a1-cbiss.com Buy Online: shop.a1-cbiss.com Cert No. 996 ISO 9001