1. The document provides instructions for safely installing and operating a water heater, including following the user manual, only allowing authorized installation, and checking that the gas type matches what the heater uses.
2. It describes the features of the heater, such as its automatic on/off system and temperature control buttons.
3. Safety warnings are given, like installing a gas leak detector and keeping flammable materials away from the heater. Contact an authorized technician for any issues.
Indirect fired water bath heaters are used in the oil and natural gas industry for a variety of applications including heating natural gas and preventing hydrate formation. TERI products include natural draft and forced draft water bath heaters and glycol dehydrators and are typically used when process temperatures do not exceed 170 degrees F.
The process of injecting the odorant into natural gas is often referred to as odorization and the equipment which adds the odorant is an odorizer.
An odorizer is traditionally able to treat natural gas at various phases of the production process. One of the reasons we are excited about Sentry Equipment’s new odorizer, the Z10000, is because it is ideal for high-pressure and high-flow odorization applications, which are more common in the Rocky Mountain States. The Z10000 system is ideal for those applications between 350 PSI and 1480 PSI, and accurate for flows ranging from 10,000 to 10,000,000 SCFH.
Here is a PowerPoint on the the Z10000.
More information is found here: http://www.lincenergysystems.com/natural-gas-products/odorizer/item/145-z10000-odorant-injection-system
Indirect fired water bath heaters are used in the oil and natural gas industry for a variety of applications including heating natural gas and preventing hydrate formation. TERI products include natural draft and forced draft water bath heaters and glycol dehydrators and are typically used when process temperatures do not exceed 170 degrees F.
The process of injecting the odorant into natural gas is often referred to as odorization and the equipment which adds the odorant is an odorizer.
An odorizer is traditionally able to treat natural gas at various phases of the production process. One of the reasons we are excited about Sentry Equipment’s new odorizer, the Z10000, is because it is ideal for high-pressure and high-flow odorization applications, which are more common in the Rocky Mountain States. The Z10000 system is ideal for those applications between 350 PSI and 1480 PSI, and accurate for flows ranging from 10,000 to 10,000,000 SCFH.
Here is a PowerPoint on the the Z10000.
More information is found here: http://www.lincenergysystems.com/natural-gas-products/odorizer/item/145-z10000-odorant-injection-system
A muffle furnace, also known as chamber or box furnace, provides the user with a cuboidal hot zone, having the depth of the hot zone generally longer than the height and the width. The hot zone is heated using either metallic, Silicon Carbide or Molybdenum Disilicide heating elements.
Five-zone split tube furnace with separated temperature control unit and max working temperature of 1100oC. It is an excellent furnace for annealing, diffusing and sintering sample in various atmospheres.
1 . Piping
2. Tank Design
3. Standpipe System
4. Pump Selection & Types
For Complete FIREFIGHTING Presentation
Check out my product on Instamojo:https://www.instamojo.com/ezazsidd1993/fire-fighting-a-complete-handbook/
Daftar Harga Pemanas Air Water Heater Ariston Pemanas Air Tenaga Listrik Kapasitas 15,30,50,80,100 Liter Tipe Pro R - RS - AN R - Shape ECO - TI Pro - Slim Harga Murah Bergaransi Resmi dari Ariston Harga Sudah Pasang Cara Pembayaran Bisa COD atau bayar di tempat dan setelah terpasang Hubungi Kami Sekarang ?
PREMIUM BOOK WITH HIGH DEFINITION QUALITY.
**A complete Guide of Fire fighting System.**
This HANDBOOK has been made from references of many books from all over the world. Which has been collected in one book.
1. Sprinkler system Type
WET PIPE SPRINKLER SYSTEM
DRY PIPE SPRINKLER SYSTEM
PRE-ACTION SYSTEM
DELUGE SYSTEM
WET PIPE ANTI FREEZE SYSTEM
FOAM WATER SPRINKLER SYSTEM
2. Sprinkler Selection
3 . Piping
4. Hydraulic Calculation
5. Standpipe System
6. Pump Selection & Types
Electric Combi Boiler Properties
3 Level Pump and Additional Pump Option
6 Different Security System
7 Days, 21 Program with Interior Timer
Anti Blockage and Freezing Prevention System
Different Temperature Value Determination For Each Program
Full Modulation, High Efficiency.
Under Floor Heating or Radiator Heating Option
If Required 3 Level Setting
Operating as 3 Phase or Single Phase
Operation Conformity with Solar Energy
Summer – Winter Mode Option
Touch Button and Easy Use Lcd Panel
A muffle furnace, also known as chamber or box furnace, provides the user with a cuboidal hot zone, having the depth of the hot zone generally longer than the height and the width. The hot zone is heated using either metallic, Silicon Carbide or Molybdenum Disilicide heating elements.
Five-zone split tube furnace with separated temperature control unit and max working temperature of 1100oC. It is an excellent furnace for annealing, diffusing and sintering sample in various atmospheres.
1 . Piping
2. Tank Design
3. Standpipe System
4. Pump Selection & Types
For Complete FIREFIGHTING Presentation
Check out my product on Instamojo:https://www.instamojo.com/ezazsidd1993/fire-fighting-a-complete-handbook/
Daftar Harga Pemanas Air Water Heater Ariston Pemanas Air Tenaga Listrik Kapasitas 15,30,50,80,100 Liter Tipe Pro R - RS - AN R - Shape ECO - TI Pro - Slim Harga Murah Bergaransi Resmi dari Ariston Harga Sudah Pasang Cara Pembayaran Bisa COD atau bayar di tempat dan setelah terpasang Hubungi Kami Sekarang ?
PREMIUM BOOK WITH HIGH DEFINITION QUALITY.
**A complete Guide of Fire fighting System.**
This HANDBOOK has been made from references of many books from all over the world. Which has been collected in one book.
1. Sprinkler system Type
WET PIPE SPRINKLER SYSTEM
DRY PIPE SPRINKLER SYSTEM
PRE-ACTION SYSTEM
DELUGE SYSTEM
WET PIPE ANTI FREEZE SYSTEM
FOAM WATER SPRINKLER SYSTEM
2. Sprinkler Selection
3 . Piping
4. Hydraulic Calculation
5. Standpipe System
6. Pump Selection & Types
Electric Combi Boiler Properties
3 Level Pump and Additional Pump Option
6 Different Security System
7 Days, 21 Program with Interior Timer
Anti Blockage and Freezing Prevention System
Different Temperature Value Determination For Each Program
Full Modulation, High Efficiency.
Under Floor Heating or Radiator Heating Option
If Required 3 Level Setting
Operating as 3 Phase or Single Phase
Operation Conformity with Solar Energy
Summer – Winter Mode Option
Touch Button and Easy Use Lcd Panel
Wall Hung Electric Boiler
3 level pump and additional pump option
6 different security system
7 days, 21 program
Anti blockage and freezing prevention system
Different temperature value determination for each program
Full modulation, high efficiency.
Grounding heating or radiator heating option
If required 3 level setting
Operating as 3 phase or single phase
Operation conformity with solar energy
Summer – Winter mode option
Touch Button and easy use LCD panel
Cara Pasang Ariston Water Heater electric 082122541663 atau pemanas air listrik merupakan alat pemanas air yang menggunakan energi listrik sebagai sumber energinya untuk dapat memenuhi kebutuhan mandi air panas keluarga Anda secara praktis. Sebenarnya, untuk pemasangan alat ini bisa dilakukan sendiri tanpa harus memakai jasa tukang. Dengan begitu kita dapat lebih menghemat biaya pengeluaran untuk membayar jasa tukang untuk memasang water heater listrik.
Berikut ini hal yang perlu diperhatikan untuk memasang water heater atau pemanas air listrik :
· Sebelum memasang pemanas air, Anda perlu menyiapkan instalasi pipa untuk jalur air panas dan jalur air dingin yang masuk ke dalam water heater. Pipa yang digunakan untuk saluran air panas pada pemanas air tentunya harus pipa khusus yang tahan terhadap panas tinggi seperti pipa dengan material polypropylene, serta material non-korosif yang tahan terhadap berbagai cairan kimia dan bebas dari sedimentasi (pengikisan).
· Kran mixing atau yang biasa kita kenal dengan kran panas dingin yang memiliki 2 saluran yaitu saluran air panas dan saluran air dingin yang nantinya akan digunakan untuk menyalurkan air dari water heater.
· Alat water heater listrik lebih baik dipasang minimal 1.5m dari lantai agar memudahkan Anda dalam pemasangan dan pengaturan pada water heater serta agar terhindar dari cipratan air mandi.
Service ariston kelapa gading 0813-8024-0365komporariston
Service center ariston kelapa gading swh Sebuah pemanas air tenaga matahari (Water Heater) dapat menjadi solusi yang tepat untuk rumah anda. Jika anda frustrasi dengan biaya listrik rumah anda, mungkin sudah saatnya untuk menjangkau solusi energi yang lebih efisien. Anda bisa mendapatkan pemanas air lain yang jauh lebih efisien daripada yang anda miliki. Tenaga matahari tersedia melimpah tak terbatas untuk anda, ini solusi yang memberi manfaat untuk Anda
Cara Pasang Ariston Water Heater electric 082122541663 atau pemanas air listrik merupakan alat pemanas air yang menggunakan energi listrik sebagai sumber energinya untuk dapat memenuhi kebutuhan mandi air panas keluarga Anda secara praktis. Sebenarnya, untuk pemasangan alat ini bisa dilakukan sendiri tanpa harus memakai jasa tukang. Dengan begitu kita dapat lebih menghemat biaya pengeluaran untuk membayar jasa tukang untuk memasang water heater listrik.
Berikut ini hal yang perlu diperhatikan untuk memasang water heater atau pemanas air listrik :
· Sebelum memasang pemanas air, Anda perlu menyiapkan instalasi pipa untuk jalur air panas dan jalur air dingin yang masuk ke dalam water heater. Pipa yang digunakan untuk saluran air panas pada pemanas air tentunya harus pipa khusus yang tahan terhadap panas tinggi seperti pipa dengan material polypropylene, serta material non-korosif yang tahan terhadap berbagai cairan kimia dan bebas dari sedimentasi (pengikisan).
· Kran mixing atau yang biasa kita kenal dengan kran panas dingin yang memiliki 2 saluran yaitu saluran air panas dan saluran air dingin yang nantinya akan digunakan untuk menyalurkan air dari water heater.
· Alat water heater listrik lebih baik dipasang minimal 1.5m dari lantai agar memudahkan Anda dalam pemasangan dan pengaturan pada water heater serta agar terhindar dari cipratan air mandi.
Service center ariston serpong swh Sebuah pemanas air tenaga matahari (Water Heater) dapat menjadi solusi yang tepat untuk rumah anda. Jika anda frustrasi dengan biaya listrik rumah anda, mungkin sudah saatnya untuk menjangkau solusi energi yang lebih efisien. Anda bisa mendapatkan pemanas air lain yang jauh lebih efisien daripada yang anda miliki. Tenaga matahari tersedia melimpah tak terbatas untuk anda, ini solusi yang memberi manfaat untuk Anda
SPLIT-TYPE, AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series PE Ceiling Concealed Indoor unit
[Model names]
PE-8GAK(T)
PE-10GAK(T)
PE-12GAK(T)
PE-16GAK(T)
PE-20GAK(T)
Service Solahart (021) 99316735 cikarang Kami Dari CV.DAVITAMA Menyediakan Jasa Perbaiakan Pemanas Air Solahart Solar Water Heater Tenaga Matahari Solahart Super L Series - Solahart L Series - Free Heat Gold KF-JBT - Handal ECO Ditangani teknisi berpengalaman selama puluhan tahun
OFFICE Support
Butuh informasi solahart detail mengenai produk kami? Kami melayani service, penjualan, spare part, juga melayani para member kontraktor yang ingin menjual produk kami kepada konsumen mereka. Kami juga melayani pelayanan GARANSI bagi setiap konsumen yang mendapat masalah tentang problem produk SOLAHART. Hubungi Teknisi Atau Marketing Consultan kami segera..!! CV Davi Natama
Solar Water heater Tenaga Matahari adalah sebuah alat yang berfungsi sebagai pemanas air. Water heater banyak digunakan di hotel, apartemen , rumah susun , dan perumahan. Khususnya di dataran tinggi , water heater hampir dimiliki oleh setiap rumah karena cuaca atau iklim yang dingin Sebuah pemanas air tenaga matahari (Solar Water Heater) dapat menjadi solusi yang tepat untuk rumah anda. Jika anda frustrasi dengan biaya listrik rumah anda, mungkin sudah saatnya untuk menjangkau solusi energi yang lebih efisien. Anda bisa mendapatkan pemanas air lain yang jauh lebih efisien daripada yang anda miliki. Tenaga matahari tersedia melimpah tak terbatas untuk anda, ini solusi yang memberi manfaat untuk Anda
Jual,Harga,Distributor Water Heater Pemanas Air Ariston Toko Jakarta,Bekasi,Tangerang Electrik Harga Murah Ekonomis Bergaransi Cv Fikri Mandiri Jaya 082113812149 @Copyrigh - Budi JR - 2016
SWIMMING POOL HEATER SUPPLIERS IN DUBAI BUYING GUIDE & HEATER INSTALLATION METHOD
Regardless of your type of weather, a swimming pool heater makes it possible to expand your swimming season and enjoy the warmer water in the pool. Usually, the pool/jacuzzi heater is installed after the pump and filter system are in place—the pump pushes the water through the filter and then on to the astral pool heater before returning the water to the pool.
http://ilpools.ae/swimming-pool-heater-suppliers-in-dubai/
Electric boiler with built-in tank (50 lt) - Kopya (2).pdfDaxom/Navidens
Electric Floor Standing Combi Boiler with 80LT Hot Water Tank
Electric Combi Boilers with Hot Water Tank
Instant And Continious Hot Water with 80 Liter Stainless Boiler
High Efficiency with Full Modulation Operation
Touch Operated , Easy Using Stylish Control Pannel
Can Be Operated with 3 Phase or Single Phase
Can Be Identifiable 7 Programs as Daily or Weekly
Can Be Identifiable Different Operation Temperature for Every Programme
Unti Blockage System for Pump and Three Way Valve
Double Freezing Preventation System
Operation Without Water Security System
Double Over Pressure Security System
Provides Hygienic Water with Anti Legionary Function
Because DHW Has Expansion Tank, Not Has Water Drainage Problem
Ready For Use Hot Water Within 10 Minute
Circulation Pump with Integrated Cycle Control
Protection Against to Corrosion with Mg Anode
Power Setting with 3 Level
Overheat Security System
Flow Control Security System
Floor Heating (Low Temperature) and Radiator System
Summer, Winter Position Option
Automatic Flaunting Purge Valve
Erp Pump
Second Pump Connection Option
%99 Efficiency
Harmonic Operation with Solar Energy System
Thermocar 16B08
12 Volt RV Condensing Gas boiler
12 Volt DC Condensing caravan gas boiler ( RV Boiler )
Storage Tank Capacity :16 liter
Electric heating capacity : 200 Watt for Solar
Gas heating capacity : 8 kW
Premix burner
Water pressure safety
Temperature safety
Waterless fire safety
Gas inlet: 3/8''
Hot water outlet : 3/8''
Cold water inlet : 3/8''
Height : 330 mm
Diemeter: 358 mm
Airintake duct : 50 mm
Exhaust duct: 25 mm
Wi-Fi Controller
Wall hung electric boiler adaption with external tankDaxom/Navidens
Electric boilers adaption with external tank
GENERAL SPECIFICATIONS
High Efficiency with full modulation operation
Instant and continious hot water with external boiler
Touch operated and easy using stylish control pannel
Setting boiler temperature from control pannel and
display of settings.
Can be operated three phase or single phase
Can be identifiable 7 programs as Daily or weekly
Can be identifiable different operation
temperature for every programme
Floor heating (low temperature) and radiator heating
system
Compatible operation with solar energy system
Internal three way valve
Three level pump
Unti blockage system for pump and three way valve
Power setting with three level
Summer – Winter position option
Double freezing prevention system
Overheat security system
Flow control security system
Operation without water security system
Double over pressure security system
Automatic air relief cock
Second pump connection option
%99 efficiency
6kW ile 24 kW Kapasite Aralığı
Boylerli (50 lt) Elektrikli Kombi
50 litre emaye kaplı hızlı boyler ile anında ve kesintisiz sıcak su
Tam modülasyonlu çalışma ile yüksek verim
Dokunmatik ve kullanımı kolay şık kontrol paneli
3 faz veya tek fazla çalışabilme özelliği
Günlük veya haftalık 7 program belirleyebilme
Her program için farklı çalışma sıcaklığı belirleyebilme
Yerden (düşük sıcaklık) ve radyatör ısıtma seçeneği
Güneş enerjisi sistemi ile uyumlu çalışabilme
Pompa ve üç yollu vana için anti-blokaj sistemi
Anti-lejyoner fonksiyonu ile hijyenik su sağlar
Boyler hattında genleşme tankı olduğu için su drenaj problemi olmaz
10 dakikada kullanıma hazır sıcak su
Entegre devir kontrollü sirkülasyon pompası
Mg anot ile korozyona karşı koruma
3 kademeli güç ayarı
Yaz-kış konum seçeneği
İkili donma koruma sistemi
Aşırı ısınma emniyet sistemi
Akış kontrol emniyet sistemi
Susuz çalışma emniyet sistemi
İkili aşırı basınç emniyet sistemi
Otomatik hava atma purjörü
Devir kontrollü sirkülasyonpompası
İkinci pompa bağlama seçeneği
%99 verim
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)MdTanvirMahtab2
This presentation is about the working procedure of Shahjalal Fertilizer Company Limited (SFCL). A Govt. owned Company of Bangladesh Chemical Industries Corporation under Ministry of Industries.
Final project report on grocery store management system..pdfKamal Acharya
In today’s fast-changing business environment, it’s extremely important to be able to respond to client needs in the most effective and timely manner. If your customers wish to see your business online and have instant access to your products or services.
Online Grocery Store is an e-commerce website, which retails various grocery products. This project allows viewing various products available enables registered users to purchase desired products instantly using Paytm, UPI payment processor (Instant Pay) and also can place order by using Cash on Delivery (Pay Later) option. This project provides an easy access to Administrators and Managers to view orders placed using Pay Later and Instant Pay options.
In order to develop an e-commerce website, a number of Technologies must be studied and understood. These include multi-tiered architecture, server and client-side scripting techniques, implementation technologies, programming language (such as PHP, HTML, CSS, JavaScript) and MySQL relational databases. This is a project with the objective to develop a basic website where a consumer is provided with a shopping cart website and also to know about the technologies used to develop such a website.
This document will discuss each of the underlying technologies to create and implement an e- commerce website.
CFD Simulation of By-pass Flow in a HRSG module by R&R Consult.pptxR&R Consult
CFD analysis is incredibly effective at solving mysteries and improving the performance of complex systems!
Here's a great example: At a large natural gas-fired power plant, where they use waste heat to generate steam and energy, they were puzzled that their boiler wasn't producing as much steam as expected.
R&R and Tetra Engineering Group Inc. were asked to solve the issue with reduced steam production.
An inspection had shown that a significant amount of hot flue gas was bypassing the boiler tubes, where the heat was supposed to be transferred.
R&R Consult conducted a CFD analysis, which revealed that 6.3% of the flue gas was bypassing the boiler tubes without transferring heat. The analysis also showed that the flue gas was instead being directed along the sides of the boiler and between the modules that were supposed to capture the heat. This was the cause of the reduced performance.
Based on our results, Tetra Engineering installed covering plates to reduce the bypass flow. This improved the boiler's performance and increased electricity production.
It is always satisfying when we can help solve complex challenges like this. Do your systems also need a check-up or optimization? Give us a call!
Work done in cooperation with James Malloy and David Moelling from Tetra Engineering.
More examples of our work https://www.r-r-consult.dk/en/cases-en/
Welcome to WIPAC Monthly the magazine brought to you by the LinkedIn Group Water Industry Process Automation & Control.
In this month's edition, along with this month's industry news to celebrate the 13 years since the group was created we have articles including
A case study of the used of Advanced Process Control at the Wastewater Treatment works at Lleida in Spain
A look back on an article on smart wastewater networks in order to see how the industry has measured up in the interim around the adoption of Digital Transformation in the Water Industry.
Immunizing Image Classifiers Against Localized Adversary Attacksgerogepatton
This paper addresses the vulnerability of deep learning models, particularly convolutional neural networks
(CNN)s, to adversarial attacks and presents a proactive training technique designed to counter them. We
introduce a novel volumization algorithm, which transforms 2D images into 3D volumetric representations.
When combined with 3D convolution and deep curriculum learning optimization (CLO), itsignificantly improves
the immunity of models against localized universal attacks by up to 40%. We evaluate our proposed approach
using contemporary CNN architectures and the modified Canadian Institute for Advanced Research (CIFAR-10
and CIFAR-100) and ImageNet Large Scale Visual Recognition Challenge (ILSVRC12) datasets, showcasing
accuracy improvements over previous techniques. The results indicate that the combination of the volumetric
input and curriculum learning holds significant promise for mitigating adversarial attacks without necessitating
adversary training.
Cosmetic shop management system project report.pdfKamal Acharya
Buying new cosmetic products is difficult. It can even be scary for those who have sensitive skin and are prone to skin trouble. The information needed to alleviate this problem is on the back of each product, but it's thought to interpret those ingredient lists unless you have a background in chemistry.
Instead of buying and hoping for the best, we can use data science to help us predict which products may be good fits for us. It includes various function programs to do the above mentioned tasks.
Data file handling has been effectively used in the program.
The automated cosmetic shop management system should deal with the automation of general workflow and administration process of the shop. The main processes of the system focus on customer's request where the system is able to search the most appropriate products and deliver it to the customers. It should help the employees to quickly identify the list of cosmetic product that have reached the minimum quantity and also keep a track of expired date for each cosmetic product. It should help the employees to find the rack number in which the product is placed.It is also Faster and more efficient way.
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdffxintegritypublishin
Advancements in technology unveil a myriad of electrical and electronic breakthroughs geared towards efficiently harnessing limited resources to meet human energy demands. The optimization of hybrid solar PV panels and pumped hydro energy supply systems plays a pivotal role in utilizing natural resources effectively. This initiative not only benefits humanity but also fosters environmental sustainability. The study investigated the design optimization of these hybrid systems, focusing on understanding solar radiation patterns, identifying geographical influences on solar radiation, formulating a mathematical model for system optimization, and determining the optimal configuration of PV panels and pumped hydro storage. Through a comparative analysis approach and eight weeks of data collection, the study addressed key research questions related to solar radiation patterns and optimal system design. The findings highlighted regions with heightened solar radiation levels, showcasing substantial potential for power generation and emphasizing the system's efficiency. Optimizing system design significantly boosted power generation, promoted renewable energy utilization, and enhanced energy storage capacity. The study underscored the benefits of optimizing hybrid solar PV panels and pumped hydro energy supply systems for sustainable energy usage. Optimizing the design of solar PV panels and pumped hydro energy supply systems as examined across diverse climatic conditions in a developing country, not only enhances power generation but also improves the integration of renewable energy sources and boosts energy storage capacities, particularly beneficial for less economically prosperous regions. Additionally, the study provides valuable insights for advancing energy research in economically viable areas. Recommendations included conducting site-specific assessments, utilizing advanced modeling tools, implementing regular maintenance protocols, and enhancing communication among system components.
2. Dear Daxom User,
In order to perform device’s function properly and for your safety
follow the instructions mentioned in the user manual of the device
during the mounting and the usage of the device.
In case of an unauthorized mounting and maintenance, the device
will be void from warranty cover. In addition to that, our company will
not be responsible from failure or an accident that may occur in the
device.
Please keep this user manual in good conditions for future reference.
The mounting of the water heater should be performed by an
authorized person. Please contact with our authorized dealers who
are powered by the authorized gas administration (EGO, İGDAŞ,
BOTAŞ, İZGAZ, etc). Do not attempt to operate the device by
yourself.
In case of you use LPG gas, do not mount your water heater in
places below the ground level.
Check whether your water heater conforms to the gas type you will
use or not.
Perform the hose connection in a safe way.
Be careful not to mount the water heater to the environments such as
clean air/ ventilation spaces of waste chimney, lightning and etc.
Consult with the authorized service or the companies about this
matter.
The device operates with 220-240Volt voltage. Ensure the network
voltage is 220-240 Volts.
Your water heater has no regular pipe connection since it is a
hermetic one. Therefore it is mandatory to use the system of fresh
air/waste gas pipe supplied with the device. Never connect it to the
regular chimneys.
The life time of the water heater which is determined by department
of industry is 10 years.
Safety Warnings
3. Thanks to its feature of digital constant water setting, the water
temperature will remain constant in the degree you set.
The fuel efficiency is reduced in low water temperature as your
device can operate in the desired constant water temperatures.
By the automatic water controlled on/off system, when the water
valve is opened, the water heater will be ignite automatically and the
hot water flow will be provided. When the water valve is closed, the
water flow will stop and the flame will be off automatically.
Thanks to its feature of operating with low pressure water, it will not
be affected by the low water pressure that occurs in the high
apartment flats. 2 mSS
The temperature control adjustment buttons make for users easy to
obtain different water temperature that they desire.
By the high pressure safety system, when the water pressure is
higher than it’s needed, safety valve will discharge the excess water
by become a part of a activity.
By the high temperature safety system, in case of the water getting
hotter than it is needed, the gas will be cut off automatically and the
damage of the water heater will be prevented.
The flame instability is prevented and the water is cooled after the
flame is off with the features of blowing inside the water heater before
the ignition (air fan blows air for 2~4 seconds before ignition) and the
blowing after service (air fan will go on blowing air for 10 seconds
after the water stops and the flame is off).
Thanks to the safe and reliable design of the combustion system, the
air is taken from outside by the fan for the purpose of the combustion
and it is sent out again after the combustion.
By the system of continuous electronic ignition, 100% success is
achieved in ignition.
The device is equipped with the multi-purpose safety system. Even if
the power is supplied to the water heater again in power failure, fan
failure, the blocking of the waste gas pipe or strong reverse wind
blowing the gas will be automatically cut and the automatic ignition
system will be disabled. In this case the water heater will need to be
restarted.
1. THE FEATURES AND THE CHARACTERISTICS OF
YOUR WATER HEATER
4. LCD display provides you to see the water temperature that you set.
When you press the On/Off button you can see the water flowing, the
fan turning, the temperature you set and the occurrence of the flame
on the LCD display.
UKDAX – 11ST MODEL
2. THE CONFIGURATION OF YOUR WATER HEATER .
The fuel expenses are reduced in low water
temperatures as your device can operate in the
desired constant water temperatures.
By the automatic water controlled on/off
system, when the water valve is opened, the
water heater will be ignite automatically and
the hot water flow will be provided. When the
water valve is closed, the water flow will stop
and the flame will be off automatically.
Thanks to its feature of operating with low
pressure water, it will not be affected by the
low water pressure that occurs in the high
apartment flats. 1 mSS
The temperature control setting buttons make
for users easy to obtain different water
temperature that they desire.
By the high pressure safety system, when the
water pressure is higher than it’s needed,
safety valve will discharge the excess water by
become a part of a activity.
By the high temperature safety system, in
case the water get hotter than it is needed, the
gas will be cut automatically and the damage
to the water heater will be prevented.
The flame instability is prevented and the
5. Warning: The mounting of the water heater should be performed by
an authorized person. Please contact our authorized dealers who are
powered by the authorized gas administration (EGO, İGDAŞ,
BOTAŞ, İZGAZ, etc). Do not attempt to operate your device by
yourself.
Model:DAXOM
Type: UKDAX-11ST
Device type C12
Gas category II2H3 B/P
Gas type LPG(G30/G31) Natural Gas(G20)
Gas input pressure 30mBar 20mBar
Fan Power 36 W
Water flow(Δt=25K) 11 l/min 11 l/min
Nominal power P 19,15 KW
Nominal load Q 22,8KW
Gas consumption 2,12 kg/h 2,12 kg/h
Water pressure
Min. 0,2 bar
Max. 10 bar
Electrical connection 220-240 Volt AC 50Hz 36 W IP 44
Minimum water flow 2,7 lt/dk
Normal heat load 22,8 KW
Net weight 9,8 kg
Dimensions 522 x337 x 143
Connections
Cold water 1/2'' 1/2''
Hot water 1/2'' 1/2''
Natural gas 1/2'' 1/2''
Waste gas Ø60 Ø60
Air channel Ø100 Ø100
3. TECHNICAL INFORMATIONS
4. THE MOUNTING OF YOUR WATER HEATER
6. The waste gas pipe should not be mounted to the general pipe or the
ventilation space of the building. The waste gas pipe should have an
outlet to outside buildig and there should be at least 500 mm space
from the open part of the exhaust outside the building. The open
edge of the air inlet pipe should be at least 100 away from the wall
where it is mounted.
In order to prevent the backflow of the condensed water or the rain
water to the heater , the part of the waste gas pipe remaining outside
the environment should be placed as to make a horizontal angle of 3
degrees.
Avoid the strong wind blowing as much as possible regarding the
waste gas pipe. Backflow may lead the device to get out of function.
The environment where the water heater is mounted should be free
from blocking, preventing parts and projections during the repair and
maintenance; there should be sufficient space around the device for
repair and maintenance.
Flammable and explosive substances must definitely be kept away
from the water heater.
The waste gas pipe can be extended when necessary however the
total pipe length should not exceed 2 m. The extension pipe should
be supplied by DAXOM. More than 2 brackets should not be used for
extension (including original bracket), the pipes should be
appropriately fixed.
The hole opened for the waste gas pipe in the wall after the mounting
should be filled with a substance resistant to burning and it should be
isolated.
The electrical connection of the water heater should be grounded and
there should be 2 Amp fuse.
The wall, which your water heater is mounted, should be strong as to
carry the weight of the water heater.
Do not mount your water heater on the power supplies.
Your water heater is a household device. Do not operate for a long
time in industrial managements.
4.1 Mounting Conditions and Safety Warnings
7. Drill bolts and screw holes by using the mounting template supplied
with the water heater in a place appropriate to the conditions
mentioned above.
Insert the Ø8 diameter bolt to the upper part and insert the screws to
the lower part.
Drill the 100 mm diameter waste gas pipe hole according to pipe
measurement, which is given as follows. (The waste gas pipes are
supplied with the water heater
Place the fresh air/waste gas pipe into the holes previously opened
for the exhaust as their clearance will stay outside. Mount the
relevant edge of the bracket part to the water heater flue and mount
the other edge as to pass over the waste gas pipe.
4.2. The Wall Mounting Of The Heater
4.2.1. Mountaning Of The Waste Gas Pipe
8. Insert the bolt to the mounting rings on the water heater. Fix the water
heater by tightening the nut on the bolt. Mount the pipe to the hole
opened previously on the wall as the fresh air/waste gas outlet will be
outside. Connect the relevant edges of the bracket part as to face
the water heater chimney and the pipe.
Fill hole opened for the waste gas pipe in the wall with a substance
resistant to burning and isolate it. Make sure that the isolation is
performed well and the pipe will not fall down in future times.
Be careful to avoid any accident while mounting the water heater.
Make sure the waste gas pipe is fixed as not fall down.
4.2.1.a. The Up and Side Mounting Of Waste Gas Pipe
9. Connect the cold water inlet of your device to the cold water main pie
with the ½ ‘’ flex pipe supplied with the device. The isolation seal
should be applied to the connections to prevent water leakage. There
should be a valve in the cold water main pipe line in order to cut the
water when needed.
Connect the hot water flow of the water heater to the hot water pipe
of your installation with ½’’ flex pipe supplied with the device. Use
TSE certified valve and flex pipe in the gas connection, never use
Teflon in the connection.
4.2.2. Performing of Connection of Water and Gas
10. Make sure the used gas type is the same with the one stated in the
brand plate.
Turn on the gas and power supply of the water heater . The light will
highlight on the , and buttons existing on the control
panel with a warning sound. If you turn on the tap without turning on
the power supply, your device will not operate and give an audio
warning.
By pressing the On/Off button on the control panel, see that the
lcd display is operating. By pressing the Tepm+ and Temp-
buttons set the water temperature you want between 35
o
C and 65
o
C
degrees. The water temperature you set will show stability after
some time according to the distance of the water heater to the tap
and the change of the water pressure.
Turn on the water valve. A sign will appear which shows the fan is
turning on the Lcd display with the douche ejector sign. After that
the fan which is inside will operate. After a few seconds the device
will start to operate and hot water will be ready for instantly use. In
the meantime the flame sign will occur on the lcd display. In case the
device does not operate, try these procedures again several times.
Contact the authorized service if the device does not operate.
5. USING OF THE WATER HEATER
5.1. THE Operation Of The Heater
11. The fault code may occur on the Lcd display when the device does
not operate and the device may give an audio warning. The
meanings of these codes are:
Fault codes FAILURE DESCRIPTION
E0 Water Inlet Sensor Failure
E1 No ignition
E4 Fan Failure
E6 NTC Failure
When the button is pressed the temperature you want to set will
increase and when the button is pressed the temperature you
want to set will decrease.
Your water heater has the capacity to heat 11 lt of water per minute.
If you would like to obtain high temperature from the water heater in
winter months (like 65 C) please set the adjustment valve in the cold
water inlet to minimum position.
Please check the temperature of the water with your hand before
aiming it to your body against any burning event.
5.1.1.Water And Temperature Kontrol
12. Press the SET button on the display panel to present the real
time water flow rate with range of 00 to 16. Forexample “0,8”
indicates the real time water flow rate 8L/min then pres “SET”
button to enter injection water rate setting mode. Press
“12” indicates setting water injection rate is 120 L
Shut the gas and water off after using and then in order to shut the
water heater off disconnect the power supply (with the help of fuse or
plug)
5.2.Shutting The Water Heater Off
5.1.2. Real Time Water Flow Control and Setting Water
Flow Rate
Ayarlama
13. Make sure the used gas type is the same with the one stated in the
brand plate. The use of inappropriate type of gas may lead to
accident.
The repair of the water heater as unauthorized is dangerous and it
may cause accidents.
Make sure the water heater is shot off and disconnected from the
power supply after using.
Check the connection places regularly with a detergent against the
gas leakage. Make sure there is sufficient space around the water
heater. Always take precautions against possible gas leakage and
when the gas smell is encountered, ventilate the environment by
opening the door and the windows and shut the gas valves off
urgently. Never make a phone call inside the room, do not turn the
lights on and off, do not plug anything to the electric plugs or unplug
anything before the gas leaves out completely. Do not forget that
any flame or a spark that may occur in such a case, will lead to fire or
explosion. Check the pipes, mount the places where happens
leakage again or replace with the new one. In case of a leakage not
resulting from the pipes, consult the service department or the
relevant gas administration unit.
Change urgently old or cracked pipes by controlling gas pipes
regularly.
When an unstable flame state is seen at water heaters working with
LPG it is very likely that the gas control system is not operating. Stop
using the water heater and have the device checked by an authorized
technician and get it repaired. Stop the water heater against an
accident for the water heaters working with city gas or natural gas.
Never leave the water heater and the gas open when you leave
home.
Never keep the flammable and explosive substances near the water
heater.
5.3. The Precautions to be Taken
5.4. Fire Precautions
14. Check the newly mounted water heaters carefully and make sure it
works properly before using.
Wait for about 10~20 seconds to ignite again when the flame is out.
Do not drink the water inside the water heater.
If neccessary preventations do not taken, situations which ambient
temperature deduct under the 0 degree, water inside heater can give
damage to your heater by freezing. It is possible to hinder this
situation by following below informations.
Thanks to freezing preventation of your heater, although ambient
temperature deduct under 0 degree, water that stays inside of heater
can be prevented to freezing but for become of activity of this system
although you do not use the heater, you must not disconnect
electrical connection and ON/OFF buttons on the heater pannel must
be “ON” position. At that position your heater will be heat inside water
by automatically short time working and will be prevent freezing.
Never touch the waste gas pipe during using and after a short time of
using (against skin burns)
In case the water heater fails, do not panic and stop using the heater.
Disconnect the gas and the electricity. Consult the service
department or an authorized technician.
We have been providing service free of charge during the warranty
period of the device. When you encounter a problem during using
please contact our after sales service department. The unauthorized
repair and the maintenance of the device will void its warranty cover.
Our company will not be liable for the failures and the accidents that
might occur later
6. REPAIR AND SERVICE
5.5. For The Safe Use
15. E0 Electrical connection Problem Control the connection
E1 1 Ignition fail without gas
2. Gas valve problem or cable
connection loose
3. Flame out problem
1Change the gas bottle or
turn on the gas valve.
2. Please check if
electromagnetic valve
makes it’s functions
correctly or not.
Check the electrical
connection.
3.Restart the heater again.
E3 Windpressure switch failure or
blocage in flur duct
Clean blockage and
impurity of flue duct
E4 1.Fan gives error while
operate
2.Connection of fan is wrong
1. Change the fan
2. Control the
connection
E5 1.Temperature of hot water
outlet is over 85 degree
Suyun soğuyup ve
termostad yeniden
ayarlanana kadar cihazı
kapatın. Daha sonra
cihazı tekrar açın. Turn
off the heater until water
ig getting cold and the
thermostad resets. Then
turn on the heater again.
E6 1.Water outlet sensor fail Change the water outlet
sensor.
7. MULFUNCTION
16. PROBLEM
CAUSE
No
light
on
the
control
panel
No
ignition
in
the
device
after
the
water
valve
is
opened
Ignition
with
explosion
Water
comes
from
safety
valve
of
the
heater
Smell
Abnormal
ıgnition
sound
Water
is
too
cold
in
high
degree
Water
is
too
hot
in
low
degree
Flame
does
not
go
out
although
the
water
valve
is
off
WAYS OF SOLUTION
No energy x Check the electricity fuse
Gas valve is not on x
Turn the gas valve on or perform
gas load
Gas valve semi-on x x Turn the gas valve completely
Air in the gas pipe x
Turn the device on and off until the
ignition occurs
Abnormal pressure x x x x Contact the authorized service
Water valve is not turned on
properly
x Turn the water valve on completely
Insufficient fresh air x x Ventilate until sufficient air comes
The wind pressure outside is
too much
x x Do not use for a certain time
Frozen water x Use again after the melting occurs
Insufficient water pressure x Control the water pressure
Power failure or the device is
not on
x Turn the power supply on
Blocking of the igniter x Contact the authorized service
Exchanger blocked Contact the authorized service
Failure in water control x x Contact the authorized service
Ignition pin is not in proper
position
x Contact the authorized service
Leakage in gas pipe or the flue x
Turn the main valve off. Contact the
authorized service
Water amount is too much x
Set the water adjustment valve to
minimum position
Too much brackets installed x x
Choose the appropriate mounting
area
Leakage in gas pipe or the flue X x
Turn the main valve off. Contact the
authorized service
Safety ventilation is open x Check the network water pressure
8. CHART OF TROUBLESHOOT AND CORRECT