The HY-OPTIMA™ 720 is a solid state sensor configured to operate in air background gas streams having up to 95% relative humidity and temperatures up to 65ºC
The HY-OPTIMA™ 1700 is an intrinsically safe device that incorporates our patented solid-state sensor and is configured to operate in background gas streams with up to 95% relative humidity and temperatures up to 100ºC.
H2scan’s HY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit.
H2scan’s HY-OPTIMA™ Model 2700AS Process Hydrogen Analyzing System provides a complete solution for process hydrogen measurement in refineries, chemical plants, air separation units and industrial gas manufacturing plants.
H2scan’s 2620 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit. The monitor is designed for either ceiling or wall mount. H2scan’s hydrogen-specific sensor technology has no cross sensitivity to other combustible gases, thus eliminating false positive alarms and ensuring safety system reliability.
The HY-OPTIMA™ 730 is a solid-state sensor configured to operate in background gas streams having carbon monoxide concentrations up to 100 ppm, hydrogen sulfide stream concentrations up to 1000 ppm, up to 95% relative humidity, and temperatures up to 100ºC.
The HY-OPTIMA™ 2700 explosion proof in-line hydrogen process sensors use a solid-state, non-consumable sensor that is configured to operate in process gas streams. The H2scan thin film technology provides a direct hydrogen measurement that is not cross sensitive to other gases.
H2scan’s HY-OPTIMA product line includes a range of real-time, in-line portable hydrogen monitors for process optimization in industrial applications. The end result is increased product yield, improved hydrogen utilization, and extended catalyst life.
The document describes a solid-state hydrogen sensor that uses both resistor and capacitor circuits to detect hydrogen from 15 ppm to 100% by volume. It has a palladium-nickel alloy film that provides stability and a proprietary coating that allows operation in harsh environments. An on-chip temperature control loop compensates for external fluctuations, and the sensor can operate in nitrogen, oxygen, and other inert gas backgrounds as well as multi-component and varying gas and liquid streams.
The HY-OPTIMA™ 1700 is an intrinsically safe device that incorporates our patented solid-state sensor and is configured to operate in background gas streams with up to 95% relative humidity and temperatures up to 100ºC.
H2scan’s HY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit.
H2scan’s HY-OPTIMA™ Model 2700AS Process Hydrogen Analyzing System provides a complete solution for process hydrogen measurement in refineries, chemical plants, air separation units and industrial gas manufacturing plants.
H2scan’s 2620 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit. The monitor is designed for either ceiling or wall mount. H2scan’s hydrogen-specific sensor technology has no cross sensitivity to other combustible gases, thus eliminating false positive alarms and ensuring safety system reliability.
The HY-OPTIMA™ 730 is a solid-state sensor configured to operate in background gas streams having carbon monoxide concentrations up to 100 ppm, hydrogen sulfide stream concentrations up to 1000 ppm, up to 95% relative humidity, and temperatures up to 100ºC.
The HY-OPTIMA™ 2700 explosion proof in-line hydrogen process sensors use a solid-state, non-consumable sensor that is configured to operate in process gas streams. The H2scan thin film technology provides a direct hydrogen measurement that is not cross sensitive to other gases.
H2scan’s HY-OPTIMA product line includes a range of real-time, in-line portable hydrogen monitors for process optimization in industrial applications. The end result is increased product yield, improved hydrogen utilization, and extended catalyst life.
The document describes a solid-state hydrogen sensor that uses both resistor and capacitor circuits to detect hydrogen from 15 ppm to 100% by volume. It has a palladium-nickel alloy film that provides stability and a proprietary coating that allows operation in harsh environments. An on-chip temperature control loop compensates for external fluctuations, and the sensor can operate in nitrogen, oxygen, and other inert gas backgrounds as well as multi-component and varying gas and liquid streams.
Pulp and paper applications create a notoriously harsh, high moisture and chemical-laden environment; coupled with extreme vibration in many of the processes. The following document outlines an array of level, pressure, and position applications and solutions for the pulp & paper industry.
The AX Series of Vortex inline flowmeters measure flows of liquid, gas, and steam by measuring the rate at which vortices are alternately shed from a bluff body; this rate has been shown to be directly proportional to the flow velocity.
As flow passes a bluff body in the stream, vortices create pressure differentials which are measured by a piezoelectric crystal sensor, which converts these pulses into electrical signals. The meter uses an all-welded sensor design to create a strong unit and minimize potential leakage.
The AX Series can be configured to measure anything from simple volumetric flow of liquids and saturated steam up through multivariable measurements, including mass flow rate, pressure, temperature and density of liquids and steam.
Insertion style vortex meters measure fl ow by detecting the local velocity at a strategically located position within the pipe. Using local velocity, calculated by measuring the rate at which vortices are alternately shed from a bluff body within the sensor, the AX2300 uses parameters such as fluid type, pipe size, and Reynolds number to calculate accurate measurements.
The FLUXUS G704 is FLEXIM's gas flow meter for permanent installation in nearly any gas flow metering application. Its non-intrusive measurement technology ensures a precise bi-directional, highly dynamic gas flow measurement of operational and standard volume flows.
The Martel CSI-30 and CSI-100 digital calibrators are designed to test instrumentation field of pneumatic valve actuators including, P / I transmitters, controllers, meters, switches, and recorders.
FLUXUS® measures flow non-intrusively using ultrasonic technology. The ultrasonic transducers are simply clamped on to the outside of the pipe and are never in contact with the liquid – pipe work is not necessary.
Clamp-on technology provides for maximum flexibility and the sophisticated electronics of FLUXUS® ensure the highest
possible accuracy and reliability. The measuring system, consisting of the transmitter, the transducers and the VARIOFIX mounting fixture, can be configured to meet individual requirements.
The FLUXUS® flowmeter series includes a variety of transmitters
and transducers: from basic models for standard applications up to robust measurement solutions for offshore use or for hazardous areas.
The PULSAR R86 is Magnetrol’s first industrial, 26 GHz Pulse Burst Non-contact Radar transmitter. More importantly, it’s the transmitter with the innovations today’s process industries need.
The Proteus WeldSaver™ is the leading water-safety device for flow control and leak detection in robotic welding applications. Whether monitoring coolant flow to weld guns or to the entire cooling circuit for a weld cell, the WeldSaver rapidly and reliably detects losses of flow continuity created by cap loss, hose burst, or other catastrophic event.
https://proteusind.com/mainweldsaver/
The document provides product information for the Proline Promag 10D electromagnetic flowmeter for measuring conductive liquids like water. Key specifications of the Promag 10D include measurement ranges up to 10 m/s, minimum conductivity of 50 μS/cm, operating temperature up to 60°C, accuracy of ±0.5% of reading, and pressure rating up to 16 bar. The document also provides dimensional drawings, electrical connection diagrams, and price tables for ordering the Promag 10D and additional measurement products.
Veracel andritz - i io-t - online wirelless vibration project implementa...Jaques Valle
Veracel implemented a wireless online monitoring system from Smart Diagnostics to monitor equipment reliability and prevent unexpected failures. They installed over 100 sensors across critical assets without using cables. This allowed for fast and low-cost installation. During testing and after implementation, the system accurately identified equipment issues from vibration data, helping Veracel avoid production losses through quicker fault detection and repairs. Veracel plans to expand the monitoring system to more assets and new sensor types to further improve process reliability.
TIP SERIES Flow Rate Meter & Flow Total Meter with RS-485mshasan3
This document provides specifications for a TIP Series flow rate and totalizer meter that can measure flow rates from 0.1-10 m/s or 0.3-33.3 ft/s in pipes from 1/2-24 inches. It has a ceramic rotor and bearings, accuracy of ±0.5% of full scale, and outputs flow rate and totalizer data via Modbus RTU communication or pulse outputs. The meter body can be made of PVC, polypropylene, or PVDF plastic and is IP65 rated.
Azbil North America recently added the AX series of multivariable vortex flowmeters for industrial process measurement and control to their product offering. The instrument combines temperature, pressure and velocity measurement in a single instrument to provide accurate mass flow measurement of gases, liquids and steam.
This document discusses portable gas detection technology from Dräger. It highlights Dräger's extensive product range for gas detection, including single and multi-gas detectors, and gas detection instruments with photoionization, catalytic, infrared, and electrochemical sensors. It also discusses Dräger's services for gas detection including consulting, training, and instrument management. The document emphasizes that Dräger gas detection technology has been proven in millions of applications worldwide for its reliability, robust design, and ease of use.
The Hallikainen Model 1354 Vapour Pressure Analyser is a completely automated process stream analyser.
Its fast response and minimal maintenance requirements put the 1354 at the forefront of your vapour pressure measurement needs.
SICK AG is a leading manufacturer of sensor technology products with over 5,800 employees worldwide. The document provides an overview of SICK's fluid sensor products, including level sensors, flow sensors, pressure sensors, and temperature sensors. It describes the company's wide product range and comprehensive services. Customers can find product information and order sensors through SICK's online portal.
The HY-OPTIMA™ 740 is a solid-state sensor configured to operate in background gas streams having carbon monoxide concentrations up to 20% by volume, hydrogen sulfide stream concentrations up to 10% by volume, up to 95% relative humidity, and temperatures up to 100ºC.
H2scan’s HY-ALERTA™ 600 Fixed Area Hydrogen Monitor will provide hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit
This document summarizes the specifications of a microprocessor-controlled centrifuge. It has a brushless induction motor, programmable microprocessor control to preset RPM from 100 to 20,000, and temperature control from 10 to 40 degrees Celsius. It displays readings like RPM, RCF, time remaining, and temperature. Key specifications include a maximum speed of 18,000 RPM, RCF of 25,200, accommodating tubes up to 100 ml, and a lowest temperature of -10 degrees Celsius. It also lists specifications for interchangeable rotor heads with different capacities and speeds.
Series RHPLC Wall Mount Humidity/Temperature TransmitterDwyer Instruments
The Series RHPLC Wall Mount Humidity/Temperature Transmitter is a compact economical sensor for the building automation market space. The stylish housing is well vented to provide air flow across the sensor to improve measurement accuracy. Each unit utilizes a capacitive polymer sensing element to deliver a proportional analog output. A combination humidity and temperature model can be configured with current, voltage, RTD, or thermistor output. A wide selection of passive RTD or thermistor temperature sensors are available in this series.
Learn more or order at www.dwyer-inst.com/Product/AirQuality/Humidity-TemperatureTransmitters/SeriesRHPLC
Pulp and paper applications create a notoriously harsh, high moisture and chemical-laden environment; coupled with extreme vibration in many of the processes. The following document outlines an array of level, pressure, and position applications and solutions for the pulp & paper industry.
The AX Series of Vortex inline flowmeters measure flows of liquid, gas, and steam by measuring the rate at which vortices are alternately shed from a bluff body; this rate has been shown to be directly proportional to the flow velocity.
As flow passes a bluff body in the stream, vortices create pressure differentials which are measured by a piezoelectric crystal sensor, which converts these pulses into electrical signals. The meter uses an all-welded sensor design to create a strong unit and minimize potential leakage.
The AX Series can be configured to measure anything from simple volumetric flow of liquids and saturated steam up through multivariable measurements, including mass flow rate, pressure, temperature and density of liquids and steam.
Insertion style vortex meters measure fl ow by detecting the local velocity at a strategically located position within the pipe. Using local velocity, calculated by measuring the rate at which vortices are alternately shed from a bluff body within the sensor, the AX2300 uses parameters such as fluid type, pipe size, and Reynolds number to calculate accurate measurements.
The FLUXUS G704 is FLEXIM's gas flow meter for permanent installation in nearly any gas flow metering application. Its non-intrusive measurement technology ensures a precise bi-directional, highly dynamic gas flow measurement of operational and standard volume flows.
The Martel CSI-30 and CSI-100 digital calibrators are designed to test instrumentation field of pneumatic valve actuators including, P / I transmitters, controllers, meters, switches, and recorders.
FLUXUS® measures flow non-intrusively using ultrasonic technology. The ultrasonic transducers are simply clamped on to the outside of the pipe and are never in contact with the liquid – pipe work is not necessary.
Clamp-on technology provides for maximum flexibility and the sophisticated electronics of FLUXUS® ensure the highest
possible accuracy and reliability. The measuring system, consisting of the transmitter, the transducers and the VARIOFIX mounting fixture, can be configured to meet individual requirements.
The FLUXUS® flowmeter series includes a variety of transmitters
and transducers: from basic models for standard applications up to robust measurement solutions for offshore use or for hazardous areas.
The PULSAR R86 is Magnetrol’s first industrial, 26 GHz Pulse Burst Non-contact Radar transmitter. More importantly, it’s the transmitter with the innovations today’s process industries need.
The Proteus WeldSaver™ is the leading water-safety device for flow control and leak detection in robotic welding applications. Whether monitoring coolant flow to weld guns or to the entire cooling circuit for a weld cell, the WeldSaver rapidly and reliably detects losses of flow continuity created by cap loss, hose burst, or other catastrophic event.
https://proteusind.com/mainweldsaver/
The document provides product information for the Proline Promag 10D electromagnetic flowmeter for measuring conductive liquids like water. Key specifications of the Promag 10D include measurement ranges up to 10 m/s, minimum conductivity of 50 μS/cm, operating temperature up to 60°C, accuracy of ±0.5% of reading, and pressure rating up to 16 bar. The document also provides dimensional drawings, electrical connection diagrams, and price tables for ordering the Promag 10D and additional measurement products.
Veracel andritz - i io-t - online wirelless vibration project implementa...Jaques Valle
Veracel implemented a wireless online monitoring system from Smart Diagnostics to monitor equipment reliability and prevent unexpected failures. They installed over 100 sensors across critical assets without using cables. This allowed for fast and low-cost installation. During testing and after implementation, the system accurately identified equipment issues from vibration data, helping Veracel avoid production losses through quicker fault detection and repairs. Veracel plans to expand the monitoring system to more assets and new sensor types to further improve process reliability.
TIP SERIES Flow Rate Meter & Flow Total Meter with RS-485mshasan3
This document provides specifications for a TIP Series flow rate and totalizer meter that can measure flow rates from 0.1-10 m/s or 0.3-33.3 ft/s in pipes from 1/2-24 inches. It has a ceramic rotor and bearings, accuracy of ±0.5% of full scale, and outputs flow rate and totalizer data via Modbus RTU communication or pulse outputs. The meter body can be made of PVC, polypropylene, or PVDF plastic and is IP65 rated.
Azbil North America recently added the AX series of multivariable vortex flowmeters for industrial process measurement and control to their product offering. The instrument combines temperature, pressure and velocity measurement in a single instrument to provide accurate mass flow measurement of gases, liquids and steam.
This document discusses portable gas detection technology from Dräger. It highlights Dräger's extensive product range for gas detection, including single and multi-gas detectors, and gas detection instruments with photoionization, catalytic, infrared, and electrochemical sensors. It also discusses Dräger's services for gas detection including consulting, training, and instrument management. The document emphasizes that Dräger gas detection technology has been proven in millions of applications worldwide for its reliability, robust design, and ease of use.
The Hallikainen Model 1354 Vapour Pressure Analyser is a completely automated process stream analyser.
Its fast response and minimal maintenance requirements put the 1354 at the forefront of your vapour pressure measurement needs.
SICK AG is a leading manufacturer of sensor technology products with over 5,800 employees worldwide. The document provides an overview of SICK's fluid sensor products, including level sensors, flow sensors, pressure sensors, and temperature sensors. It describes the company's wide product range and comprehensive services. Customers can find product information and order sensors through SICK's online portal.
The HY-OPTIMA™ 740 is a solid-state sensor configured to operate in background gas streams having carbon monoxide concentrations up to 20% by volume, hydrogen sulfide stream concentrations up to 10% by volume, up to 95% relative humidity, and temperatures up to 100ºC.
H2scan’s HY-ALERTA™ 600 Fixed Area Hydrogen Monitor will provide hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit
This document summarizes the specifications of a microprocessor-controlled centrifuge. It has a brushless induction motor, programmable microprocessor control to preset RPM from 100 to 20,000, and temperature control from 10 to 40 degrees Celsius. It displays readings like RPM, RCF, time remaining, and temperature. Key specifications include a maximum speed of 18,000 RPM, RCF of 25,200, accommodating tubes up to 100 ml, and a lowest temperature of -10 degrees Celsius. It also lists specifications for interchangeable rotor heads with different capacities and speeds.
Series RHPLC Wall Mount Humidity/Temperature TransmitterDwyer Instruments
The Series RHPLC Wall Mount Humidity/Temperature Transmitter is a compact economical sensor for the building automation market space. The stylish housing is well vented to provide air flow across the sensor to improve measurement accuracy. Each unit utilizes a capacitive polymer sensing element to deliver a proportional analog output. A combination humidity and temperature model can be configured with current, voltage, RTD, or thermistor output. A wide selection of passive RTD or thermistor temperature sensors are available in this series.
Learn more or order at www.dwyer-inst.com/Product/AirQuality/Humidity-TemperatureTransmitters/SeriesRHPLC
Spec sheet Cemtek Model 1000 Oxygen MonitorBrian Gilmore
Key Features:
• Modular probe design with blowdown ideal for high dust,
corrosive applications
• FM Approved
• Ease of maintenance with no probe removal to replace
element
• Combustion efficiency mode available as option
• Remote control of calibration and blowdown routines via
digital inputs
• Detector sensor replacement and maintenance is half
the cost of equivalent competitive products
https://www.linkedin.com/pub/brian-gilmore/4/705/238
This document provides specifications for various combustion, tachometer, and hygrometer equipment made by Dwyer Instruments, including models that monitor carbon monoxide and dioxide levels, measure rotational speed, and measure humidity and temperature. The models can be used for applications like measuring flue gases, calibrating boiler systems, combustion tests, and monitoring indoor air quality. The document also states that Dwyer Instruments' name and logos cannot be reproduced or used without permission.
IRZ artificial lift solutions [version 1.2 july 2016]Ivan Isaev
IRZ artificial lift solutions:
- Downhole monitoring systems for ESP (downhole sensor, surface acquisition unit);
- Downhole monitoring systems with flow meter;
- Downhole monitoring systems for dual ESP production;
- Electromagnetic anti-scaling downhole system for ESP;
- Downhole monitoring systems for rod-pumps/ PCP/ Gas Lift/ Flowing Wells;
- Сontrol stations (VSD, Soft Starters, Switchboards) for ESP, PCP, rod-pumps.
The document describes several gas monitoring devices:
- The 4 Channel Gas Monitor is a wall-mounted unit that monitors up to 4 toxic gases, combustible gases, or oxygen levels with displays and alarms.
- The Multichannel Gas Monitor is a rack-mounted system compatible with up to 16 sensors for monitoring multiple gas channels.
- The IR80 CO2 Gas Monitor is a standalone or networked monitor for carbon dioxide levels with alarms and calibration assistance.
The document provides product information for the Cerabar T PMP131 pressure transmitter including:
- It measures absolute and gauge pressures from 0-25 bar using a 4-20mA output signal.
- Key features include long term stability, accuracy of <0.5%, and IP65/IP68 protection.
- It has common process connections including ANSI 1/2" and 1/4" and can operate from -25°C to +70°C.
- Accessories include displays for mounting in the field and it is available from $242 for small quantities.
The document provides technical specifications for the Cerabar T PMP135 hygienic pressure transmitter. It is designed to measure absolute and gauge pressures in hygienic applications in the food and pharmaceutical industries. Key specifications include an output of 4-20 mA, accuracy of less than 0.5%, a temperature range of -25 to 100°C, and pressure measurement ranges from 1 bar to 40 bar. It has wetted parts made of 316L stainless steel with a surface roughness of Ra ≤ 0.8 μm. Accessories like displays and process fittings are also described along with pricing information.
The PT205-LEL is a combustible hydrocarbon sensor that uses a catalytic bead sensor to detect combustible vapors from 0-100% LEL. It has a microprocessor-based modular design that provides a 4-20mA output and LED status indicator. The sensor is approved for use in hazardous locations and has a response time of less than 10 seconds for 100% LEL methane gas.
This document provides information on the Liquiline CM14, a 4-wire transmitter for mounting in control panels. It uses Memosens technology to digitally transmit measurement values from pH, conductivity, and oxygen sensors. The transmitter converts these signals into 0/4-20 mA outputs and can output temperature as a second current signal. Specifications include dimensions, inputs/outputs, power supply details, performance characteristics, and operating conditions. Price tables list available sensor kits and accessories to complete an analytical measurement point with the CM14. Contact information is provided for ordering.
The Model WCM 7300 is designed to provide highly sensitive and accurate water content measurement down to 1000 ppm in crude oil and other hydrocarbons from 25% down. It uses enhanced digital signal processing and full temperature compensation. Probe sizes from 2 to 12 inches are available with outputs for remote monitoring. A magnet switch allows viewing water cut, temperature, or electrical values without removing the cover. It measures and compensates for temperature effects on dielectric properties to provide an accurate water cut reading at any temperature up to 160°F.
The document summarizes a pH/ORP monitoring system called the Q46P/R. It offers various sensor options including differential and conventional pH sensors, as well as automatic sensor cleaning. Key features include PID control, digital communication protocols, alarm relays, and flexible mounting options. The system provides accurate measurement for various industrial applications requiring pH or ORP monitoring.
2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...Michael Sun
■ Base accuracy: ±0.15 %
■ Span limits
– 0.3 to 60000 kPa; 1.2 inH2O to 8700 psi
– 0.3 to 3000 kPa abs; 2.25 mmHg to 435 psia
■ Reliable sensing system coupled with very latest
digital technologies
– provides large turn down ratio up to 20:1
■ Stainless steel housing
– optimized for rough environment
– extreme robust
2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...Michael Sun
■ Base accuracy: ±0.15 %
■ Span limits
– 0.3 to 60000 kPa; 1.2 inH2O to 8700 psi
– 0.3 to 3000 kPa abs; 2.25 mmHg to 435 psia
■ Reliable sensing system coupled with very latest
digital technologies
– provides large turn down ratio up to 20:1
■ Stainless steel housing
– optimized for rough environment
– extreme robust
The High Precision Microprocessor Based DO Meter are high end analytical application, accurate DO meters.For more information please log on http://cutt.us/5725
Untuk informasi lebih lanjut dan pemesanan produk, dapat menghubungi Siwali Jakarta : 021-45850618/ Siwali Surabaya: 031-8421278.
Distributor Rotronic di Indonesia - PT. Siwali Swantika (www.siwali.com)
Similar to Hy optima-720-technical-data-sheet solid state sensor (20)
We fotograferen, scannen woningen, gebouwen, constructies voor vastgoedmakelaars, architecten, projectontwikkelaars, aannemers,...
Daarnaast maken we 360° scans, virtual tours, grondplannen, luchtfoto's met
drones, mapping en nog veel meer.
Diensten voor vastgoed
Standaard fotografie
3d scans
Virtual tours
2d vloerplannen
Drone foto -en videografie
Virtual staging
Nabewerken foto's
Vastgoed teaser videos
Diensten voor
constructies
Foto en video
3d scans
E57 files
Vloerplannen
Puntenwolken
Mesh bestanden
Trueplan
Luchtfoto's
en meer
XRF Based &Multi-Metals & Continuous Water Analyzer Xact920European Tech Serv
Process monitoring – feedback for water treatment may improve the efficiency of the treatment process – use fewer chemicals to achieve require effluent emission limits
Measurement of Se, As for compliance with Steam Electric Generating Effluent Guidelines
Monitoring of treatment of wastewater by biological based treatment systems
Measurement of Corrosion Products (e.g. Fe, Ni, Cr and Mn) to improve operating efficiency
Measurement of Elements in Nuclear Power Plant Applications (e.g. Pb, Cu, Fe)
Reduce laboratory analysis costs
On-line, in-situ, and at-line monitoring of batch and continuous processes
Displays up to 15 properties at once and measures up to 30 properties per stream
Optical multiplexing capabilities provide analysis of up to 16 process streams using fiber optic or extractive stream switching
Utilizes process-proven ANALECT® Diamond 20™ Transept™ optical head
SpectraRTS™ software engineered exclusively for on-line monitoring, allowing use by engineers, maintenance personnel, and chemists
All ANALECT® lab and on-line systems share core optical technology, allowing instrument-to-instrument calibration transfers
The FROG-5000™ is a portable gas chromatograph (GC) that identifies multiple target volatile organic compounds (VOC) in water, soil, and air. The FROG-5000™ detects chemicals as volatile as vinyl chloride to semi-volatile organics such as naphthalene with lab quality results.
Featuring a MEMS (micro electro-mechanical systems), the FROG-5000™ has an integrated heater for temperature ramp chromatography – ramping the temperature reduces the analysis time and aids in the separation of late eluting compounds. These components combined with an internal PID identify VOCs in ambient air at concentrations as low as 1 part per billion.
Continuous analysis:
Continuous analysis of aerosols on filters for optical and thermal analysis
OC/EC determination:
Real time/online TC/BC/EC/OC and Brc analysis in combination with our Aethalometer AE33
Ease of Use:
No fragile glassware, no catalyst, no gas supplies needed
Rugged, Reliable, automatic:
35 years of published performance, rugged, all-steel construction, unattended operation – 1 month minimum
At the core of our technology are our next‑generation air quality monitors - the Clarity Node and Node-S. These nimble monitors are configured on our web-based deployment tool and installed in a matter of minutes. Hundreds to thousands of devices work together to form a scalable network of high density air quality measurement points.
At the core of our technology are our next‑generation air quality monitors - the Clarity Node and Node-S. These nimble monitors are configured on our web-based deployment tool and installed in a matter of minutes. Hundreds to thousands of devices work together to form a scalable network of high density air quality measurement points.
At the core of our technology are our next‑generation air quality monitors - the Clarity Node and Node-S. These nimble monitors are configured on our web-based deployment tool and installed in a matter of minutes. Hundreds to thousands of devices work together to form a scalable network of high density air quality measurement points.
At the core of our technology are our next‑generation air quality monitors - the Clarity Node and Node-S. These nimble monitors are configured on our web-based deployment tool and installed in a matter of minutes. Hundreds to thousands of devices work together to form a scalable network of high density air quality measurement points.
The Mi3 is a turnkey solution for automotive emission testing that features the world's fastest particle sensor. It provides accurate real-time data, reliable measurements in all environments, and ensures measurements meet emission regulations standards. The Mi3 requires little maintenance due to its low-maintenance particle sensor and self-diagnostics. It can integrate seamlessly with existing emission test infrastructure through various connection options.
THE GAS CHROMATOGRAPHIC REVOLUTION
FOR ENVIRONMENTAL MONITORING
PyxisGC BTEX is the first and unique gaschromatograph "carrier gas free" for remote BTEX monitoring
in ambient air. PyxisGC BTEX is manufactured by Pollution Analytical Equipment in compliance with
EN14662-3:2015.
"BTEX ambient air analysis: sources, regulations, technologies for controls"European Tech Serv
"BTEX ambient air analysis: sources, regulations, technologies for
controls"
In collaboration with The Council for Research and Experimentation in Agriculture at the Puglia
Regional Environmental Protection Agency (ARPA)
The M1000 operates according to the diffusion principle. The monitor is mounted on a flange which is located at the top of the silo or bin. The gas in the atmosphere of the silo diffuses into the oxygen sensor. Since there is no positive movement of chemical powder to the sensor the sampling gas will not block filters and tubing. The right design and choice of components ensures a long term maintenance free operation.
H2scan’s HY-ALERTA™ 600 Fixed Area Hydrogen Monitor will provide hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit
H2scan’s HY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit.
H2scan’s HY-ALERTA™ 2600 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s lower flammability limit.
Technology background HY-ALERTA SAFETY SYSTEMS – HY-ALERTA 2600European Tech Serv
H2scan’s HY-ALERTA™ 2600 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s lower flammability limit.
H2scan’s 2620 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit. The monitor is designed for either ceiling or wall mount. H2scan’s hydrogen-specific sensor technology has no cross sensitivity to other combustible gases, thus eliminating false positive alarms and ensuring safety system reliability.
The document describes a solid-state hydrogen sensor that uses both resistor and capacitor circuits to detect hydrogen from 15 ppm to 100% by volume. It has a palladium-nickel alloy film that provides stability and a proprietary coating that allows operation in harsh environments. An on-chip temperature control loop compensates for external fluctuations, and the sensor can operate in nitrogen, oxygen, and other inert gas backgrounds as well as multi-component and varying gas and liquid streams.
Improving the viability of probiotics by encapsulation methods for developmen...Open Access Research Paper
The popularity of functional foods among scientists and common people has been increasing day by day. Awareness and modernization make the consumer think better regarding food and nutrition. Now a day’s individual knows very well about the relation between food consumption and disease prevalence. Humans have a diversity of microbes in the gut that together form the gut microflora. Probiotics are the health-promoting live microbial cells improve host health through gut and brain connection and fighting against harmful bacteria. Bifidobacterium and Lactobacillus are the two bacterial genera which are considered to be probiotic. These good bacteria are facing challenges of viability. There are so many factors such as sensitivity to heat, pH, acidity, osmotic effect, mechanical shear, chemical components, freezing and storage time as well which affects the viability of probiotics in the dairy food matrix as well as in the gut. Multiple efforts have been done in the past and ongoing in present for these beneficial microbial population stability until their destination in the gut. One of a useful technique known as microencapsulation makes the probiotic effective in the diversified conditions and maintain these microbe’s community to the optimum level for achieving targeted benefits. Dairy products are found to be an ideal vehicle for probiotic incorporation. It has been seen that the encapsulated microbial cells show higher viability than the free cells in different processing and storage conditions as well as against bile salts in the gut. They make the food functional when incorporated, without affecting the product sensory characteristics.
Optimizing Post Remediation Groundwater Performance with Enhanced Microbiolog...Joshua Orris
Results of geophysics and pneumatic injection pilot tests during 2003 – 2007 yielded significant positive results for injection delivery design and contaminant mass treatment, resulting in permanent shut-down of an existing groundwater Pump & Treat system.
Accessible source areas were subsequently removed (2011) by soil excavation and treated with the placement of Emulsified Vegetable Oil EVO and zero-valent iron ZVI to accelerate treatment of impacted groundwater in overburden and weathered fractured bedrock. Post pilot test and post remediation groundwater monitoring has included analyses of CVOCs, organic fatty acids, dissolved gases and QuantArray® -Chlor to quantify key microorganisms (e.g., Dehalococcoides, Dehalobacter, etc.) and functional genes (e.g., vinyl chloride reductase, methane monooxygenase, etc.) to assess potential for reductive dechlorination and aerobic cometabolism of CVOCs.
In 2022, the first commercial application of MetaArray™ was performed at the site. MetaArray™ utilizes statistical analysis, such as principal component analysis and multivariate analysis to provide evidence that reductive dechlorination is active or even that it is slowing. This creates actionable data allowing users to save money by making important site management decisions earlier.
The results of the MetaArray™ analysis’ support vector machine (SVM) identified groundwater monitoring wells with a 80% confidence that were characterized as either Limited for Reductive Decholorination or had a High Reductive Reduction Dechlorination potential. The results of MetaArray™ will be used to further optimize the site’s post remediation monitoring program for monitored natural attenuation.
RoHS stands for Restriction of Hazardous Substances, which is also known as t...vijaykumar292010
RoHS stands for Restriction of Hazardous Substances, which is also known as the Directive 2002/95/EC. It includes the restrictions for the use of certain hazardous substances in electrical and electronic equipment. RoHS is a WEEE (Waste of Electrical and Electronic Equipment).
Kinetic studies on malachite green dye adsorption from aqueous solutions by A...Open Access Research Paper
Water polluted by dyestuffs compounds is a global threat to health and the environment; accordingly, we prepared a green novel sorbent chemical and Physical system from an algae, chitosan and chitosan nanoparticle and impregnated with algae with chitosan nanocomposite for the sorption of Malachite green dye from water. The algae with chitosan nanocomposite by a simple method and used as a recyclable and effective adsorbent for the removal of malachite green dye from aqueous solutions. Algae, chitosan, chitosan nanoparticle and algae with chitosan nanocomposite were characterized using different physicochemical methods. The functional groups and chemical compounds found in algae, chitosan, chitosan algae, chitosan nanoparticle, and chitosan nanoparticle with algae were identified using FTIR, SEM, and TGADTA/DTG techniques. The optimal adsorption conditions, different dosages, pH and Temperature the amount of algae with chitosan nanocomposite were determined. At optimized conditions and the batch equilibrium studies more than 99% of the dye was removed. The adsorption process data matched well kinetics showed that the reaction order for dye varied with pseudo-first order and pseudo-second order. Furthermore, the maximum adsorption capacity of the algae with chitosan nanocomposite toward malachite green dye reached as high as 15.5mg/g, respectively. Finally, multiple times reusing of algae with chitosan nanocomposite and removing dye from a real wastewater has made it a promising and attractive option for further practical applications.
Evolving Lifecycles with High Resolution Site Characterization (HRSC) and 3-D...Joshua Orris
The incorporation of a 3DCSM and completion of HRSC provided a tool for enhanced, data-driven, decisions to support a change in remediation closure strategies. Currently, an approved pilot study has been obtained to shut-down the remediation systems (ISCO, P&T) and conduct a hydraulic study under non-pumping conditions. A separate micro-biological bench scale treatability study was competed that yielded positive results for an emerging innovative technology. As a result, a field pilot study has commenced with results expected in nine-twelve months. With the results of the hydraulic study, field pilot studies and an updated risk assessment leading site monitoring optimization cost lifecycle savings upwards of $15MM towards an alternatively evolved best available technology remediation closure strategy.
Hy optima-720-technical-data-sheet solid state sensor
1. HY-OPTIMATM
720 In-Line Process Hydrogen Analyzer
Calibration in Oxygen & Nitrogen Background
HY-OPTIMA
TM
is a registered Trademark of H2scan 27215 Turnberry Lane, Unit A, Valencia, CA, 91355
Specifications subject to change without prior notice Tel: 661-775-9575, Fax: 661-775-9515
90000020 R4 Email: sales@h2scan.com, Website: www.h2scan.com
Operating Conditions
Operating Humidity: 0% to 95% RH
Flow Rate: 0.1 slpm to 50 slpm
Pressure: 0 to 7 bar gauge, 0 to 100 psi gauge
Process Gas Temperature Range: -20ºC to 65ºC
Operating Temperature Range: -20ºC to 40ºC
Storage Temperature Range: -40ºC to 50ºC
Calibration Background Gas: Air & Nitrogen
Adapter Fittings
½ in. MNPT thread
½ in. FNPT thread
-8 SAE/MS thread size
... and many other industry standards
Dimensions
Total Length: 9.1 in.
Length of Enclosure: 6.7 in.
Length of Tube: 2.4 in.
Width: 3.4 in.
Depth: 1.4 in.
Description
H2scan’s Series 700 in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface
flexibility and true process control. The HY-OPTIMATM
720 is a solid state sensor configured to operate in air &
Nitrogen background gas streams having up to 95% relative humidity and temperatures up to 65ºC. The HY-
OPTIMATM
720 is ideal for the monitoring of hydrogen processes where real time measurements of hydrogen can
ensure safety in application, increase process efficiencies, improve diagnostics and enhance maintenance
management translating into higher profitability.
Performance
Hydrogen Sensitivity Range:
0.4% to 5% hydrogen by volume at 1 ATM
Typical Response Time: T90 of 60 sec maximum
Ingress Protection: IP64 capable
Calibration Interval: 90 days
Product Life Expectancy: 10 years
Accuracy: ± (0.03 x indication + 0.2) percent
hydrogen by volume
Interface Options
Input Voltage Range: 8 VDC to 13 VDC
Input Current: 1.0 A
Analog Outputs:
Output Voltages - OR - Output Currents
0 VDC to 5 VDC 4 mA to 20 mA
1 VDC to 5 VDC 0 mA to 20 mA
0 VDC to 4 VDC User-specific mA range
0.5 VDC to 4.5 VDC
User-specific VDC range
Serial Communication Options: RS232 or RS422
Relay Contacts: Two programmable 60 VDC / 1 A
SPDT relays with both normally open (N.O.)
and normally closed (N.C.) contacts
Certification: