H2scan’s HY-OPTIMA™ Model 2700AS Process Hydrogen Analyzing System provides a complete solution for process hydrogen measurement in refineries, chemical plants, air separation units and industrial gas manufacturing plants.
The HY-OPTIMA™ 2700 explosion proof in-line hydrogen process sensors use a solid-state, non-consumable sensor that is configured to operate in process gas streams. The H2scan thin film technology provides a direct hydrogen measurement that is not cross sensitive to other gases.
H2scan’s HY-OPTIMA product line includes a range of real-time, in-line portable hydrogen monitors for process optimization in industrial applications. The end result is increased product yield, improved hydrogen utilization, and extended catalyst life.
H2scan’s 2620 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit. The monitor is designed for either ceiling or wall mount. H2scan’s hydrogen-specific sensor technology has no cross sensitivity to other combustible gases, thus eliminating false positive alarms and ensuring safety system reliability.
The document describes a solid-state hydrogen sensor that uses both resistor and capacitor circuits to detect hydrogen from 15 ppm to 100% by volume. It has a palladium-nickel alloy film that provides stability and a proprietary coating that allows operation in harsh environments. An on-chip temperature control loop compensates for external fluctuations, and the sensor can operate in nitrogen, oxygen, and other inert gas backgrounds as well as multi-component and varying gas and liquid streams.
The HY-OPTIMA™ 720 is a solid state sensor configured to operate in air background gas streams having up to 95% relative humidity and temperatures up to 65ºC
Lyssy l80 5000 Water Vapour Permeability TesterSystechIllinois
Easy and reliable testing for water vapour permeability. The L80-5000 is the latest generation of the proven L80 series, which has been used successfully for decades in many labs. With the L80-5000, the testing of water vapour permeability becomes very simple.
H2scan’s HY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit.
The HY-OPTIMA™ 1700 is an intrinsically safe device that incorporates our patented solid-state sensor and is configured to operate in background gas streams with up to 95% relative humidity and temperatures up to 100ºC.
The Graphite 52M is a heated FID volatile organic compounds analyzer that allows for continuous and accurate total VOC monitoring. It features a heated detector block up to 191°C that eliminates condensation and allows for measurement of heavy hydrocarbons. The compact device has a fast response time and is fully supported by certified data acquisition software. It is suitable for applications such as waste incineration monitoring in compliance with relevant standards and directives.
The HY-OPTIMA™ 2700 explosion proof in-line hydrogen process sensors use a solid-state, non-consumable sensor that is configured to operate in process gas streams. The H2scan thin film technology provides a direct hydrogen measurement that is not cross sensitive to other gases.
H2scan’s HY-OPTIMA product line includes a range of real-time, in-line portable hydrogen monitors for process optimization in industrial applications. The end result is increased product yield, improved hydrogen utilization, and extended catalyst life.
H2scan’s 2620 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit. The monitor is designed for either ceiling or wall mount. H2scan’s hydrogen-specific sensor technology has no cross sensitivity to other combustible gases, thus eliminating false positive alarms and ensuring safety system reliability.
The document describes a solid-state hydrogen sensor that uses both resistor and capacitor circuits to detect hydrogen from 15 ppm to 100% by volume. It has a palladium-nickel alloy film that provides stability and a proprietary coating that allows operation in harsh environments. An on-chip temperature control loop compensates for external fluctuations, and the sensor can operate in nitrogen, oxygen, and other inert gas backgrounds as well as multi-component and varying gas and liquid streams.
The HY-OPTIMA™ 720 is a solid state sensor configured to operate in air background gas streams having up to 95% relative humidity and temperatures up to 65ºC
Lyssy l80 5000 Water Vapour Permeability TesterSystechIllinois
Easy and reliable testing for water vapour permeability. The L80-5000 is the latest generation of the proven L80 series, which has been used successfully for decades in many labs. With the L80-5000, the testing of water vapour permeability becomes very simple.
H2scan’s HY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit.
The HY-OPTIMA™ 1700 is an intrinsically safe device that incorporates our patented solid-state sensor and is configured to operate in background gas streams with up to 95% relative humidity and temperatures up to 100ºC.
The Graphite 52M is a heated FID volatile organic compounds analyzer that allows for continuous and accurate total VOC monitoring. It features a heated detector block up to 191°C that eliminates condensation and allows for measurement of heavy hydrocarbons. The compact device has a fast response time and is fully supported by certified data acquisition software. It is suitable for applications such as waste incineration monitoring in compliance with relevant standards and directives.
The reliable identification of low combustion oxygen in a red heater or boiler has always been critical to the effectiveness of the Burner Management System for proper control and safety.
Low emission burners and aggressive ring control points to achieve increased efficiency and emission reductions have driven the industry to tighter control measures. But tighter control measures also hold a greater potential for combustion damage. Reducing the risk of a combustion event has become a priority and has led to the implementation of Safety Instrumented Systems (SIS). This additional layer of safety is added to the Basic Process Control System.
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...ENVIMART
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for nitrite - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
Pulp and paper applications create a notoriously harsh, high moisture and chemical-laden environment; coupled with extreme vibration in many of the processes. The following document outlines an array of level, pressure, and position applications and solutions for the pulp & paper industry.
This document discusses portable gas detection technology from Dräger. It highlights Dräger's extensive product range for gas detection, including single and multi-gas detectors, and gas detection instruments with photoionization, catalytic, infrared, and electrochemical sensors. It also discusses Dräger's services for gas detection including consulting, training, and instrument management. The document emphasizes that Dräger gas detection technology has been proven in millions of applications worldwide for its reliability, robust design, and ease of use.
The AX Series of Vortex inline flowmeters measure flows of liquid, gas, and steam by measuring the rate at which vortices are alternately shed from a bluff body; this rate has been shown to be directly proportional to the flow velocity.
As flow passes a bluff body in the stream, vortices create pressure differentials which are measured by a piezoelectric crystal sensor, which converts these pulses into electrical signals. The meter uses an all-welded sensor design to create a strong unit and minimize potential leakage.
The AX Series can be configured to measure anything from simple volumetric flow of liquids and saturated steam up through multivariable measurements, including mass flow rate, pressure, temperature and density of liquids and steam.
Insertion style vortex meters measure fl ow by detecting the local velocity at a strategically located position within the pipe. Using local velocity, calculated by measuring the rate at which vortices are alternately shed from a bluff body within the sensor, the AX2300 uses parameters such as fluid type, pipe size, and Reynolds number to calculate accurate measurements.
Fluke Calibration on How to Calibrate an RTD Using a Dry block Calibrator Web...Transcat
This document provides guidance on how to calibrate an RTD (resistance temperature detector) using a dry-block calibrator. It discusses potential sources of error from a dry-block like immersion depth, stem conduction, contact issues and temperature non-uniformity. It recommends fully immersing probes, maintaining consistent depths between the RTD and reference probe, and accounting for uncertainties. The document then walks through calculating uncertainties, addressing odd shaped probes, temperature ranges, and provides an example of a three-point RTD calibration using a dry-block and software.
The HY-OPTIMA™ 730 is a solid-state sensor configured to operate in background gas streams having carbon monoxide concentrations up to 100 ppm, hydrogen sulfide stream concentrations up to 1000 ppm, up to 95% relative humidity, and temperatures up to 100ºC.
Intrinsically Safe ATEX, unsurpassed certified oxygen analyser for all hazardous areas. The EC91 Process Oxygen Transmitter will detect levels of oxygen as low as 1ppm, up to higher percent levels and can be used on most industrial gases and atmospheres.
Flowfit cca250 endress+hauser datasheet-flow assembly for chlorine and p h:or...ENVIMART
Flowfit cca250 endress+hauser datasheet-flow assembly for chlorine and p h:orp sensors - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
QCBox-ATEX : a photoacoustic spectrometer dedicated to process monitoring
The QCBox-ATEX is specifically tailored to monitor On-line Processes in the chemical and petrochemical industries. The quality of the materials is of prime importance to those industries and defines the commercial value of the products. The detection of impurities, pollutants or corroding compounds is paramount in adjusting the process and optimizing reactions. The QCBox-ATEX allows for the detection of minute traces of any contaminating gases in any type of gas streams.
GE Webinar: Oxygen Measurement for Chemical & Fuel Storage SafetyTranscat
This webinar will explore:
-The parameters needed for an explosion or fire to occur
-Identifying "Lower Explosive Limit"
-Measuring oxygen concentration using Thermoparamagnetic Oxygen sensors
-Application considerations and case studies
The HY-OPTIMA™ 740 is a solid-state sensor configured to operate in background gas streams having carbon monoxide concentrations up to 20% by volume, hydrogen sulfide stream concentrations up to 10% by volume, up to 95% relative humidity, and temperatures up to 100ºC.
H2scan’s HY-ALERTA™ 600 Fixed Area Hydrogen Monitor will provide hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit
The document describes several gas monitoring devices:
- The 4 Channel Gas Monitor is a wall-mounted unit that monitors up to 4 toxic gases, combustible gases, or oxygen levels with displays and alarms.
- The Multichannel Gas Monitor is a rack-mounted system compatible with up to 16 sensors for monitoring multiple gas channels.
- The IR80 CO2 Gas Monitor is a standalone or networked monitor for carbon dioxide levels with alarms and calibration assistance.
Allwin21 Corp. was formed in 2000 with a focus on professionally providing Rapid Thermal Process, Plasma Asher Strip / Descum, Plasma Etch/RIE, Sputter Deposition and Metal Film Metrology high-tech semiconductor equipment, services and technical support in Semiconductor III-V, MEMS, Biomedical, Nanotechnology, Solar, Battery & LED industries. We endeavor to be a leader in our product lines.
We focus on extending product lifecycle, providing solutions, and engineering enhancements to many production proven semiconductor process equipment most directly related to III-V processing. These semiconductor equipment have been used in production and R&D since the 1990′s. They have proven processes and research. Allwin21 Corp. customizes these systems with Allwin21′s comparable integrated process control system with PC, solid robotic wafer transfer system, and new critical components. This is to achieve the goal of giving our customers a production edge, with right cost, and without having to worry about obsolete parts.
The PT205-LEL is a combustible hydrocarbon sensor that uses a catalytic bead sensor to detect combustible vapors from 0-100% LEL. It has a microprocessor-based modular design that provides a 4-20mA output and LED status indicator. The sensor is approved for use in hazardous locations and has a response time of less than 10 seconds for 100% LEL methane gas.
Datasheet Fluke 726. Hubungi PT. Siwali Swantika 021-45850618PT. Siwali Swantika
Datasheet Fluke Precision Multifunction Process Calibrator. Informasi lebih detail hubungi PT. Siwali Swantika, Jakarta Office : 021-45850618 atau Surabaya Office : 031-8421264
AccuThermo AW 820 Long Time Rapid Thermal Anneal EquipmentPeter Chen
The document describes the AccuThermo AW820 rapid thermal processing system. It provides short heating periods from 1-900 seconds at precisely controlled temperatures using high intensity visible radiation. Key features include long steady time capability, advanced software for real-time control, consistent wafer-to-wafer repeatability, and fast heating and cooling rates. It is a production-proven standalone system for applications such as semiconductor manufacturing, compound semiconductors, MEMS, and more.
The reliable identification of low combustion oxygen in a red heater or boiler has always been critical to the effectiveness of the Burner Management System for proper control and safety.
Low emission burners and aggressive ring control points to achieve increased efficiency and emission reductions have driven the industry to tighter control measures. But tighter control measures also hold a greater potential for combustion damage. Reducing the risk of a combustion event has become a priority and has led to the implementation of Safety Instrumented Systems (SIS). This additional layer of safety is added to the Basic Process Control System.
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...ENVIMART
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for nitrite - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
Pulp and paper applications create a notoriously harsh, high moisture and chemical-laden environment; coupled with extreme vibration in many of the processes. The following document outlines an array of level, pressure, and position applications and solutions for the pulp & paper industry.
This document discusses portable gas detection technology from Dräger. It highlights Dräger's extensive product range for gas detection, including single and multi-gas detectors, and gas detection instruments with photoionization, catalytic, infrared, and electrochemical sensors. It also discusses Dräger's services for gas detection including consulting, training, and instrument management. The document emphasizes that Dräger gas detection technology has been proven in millions of applications worldwide for its reliability, robust design, and ease of use.
The AX Series of Vortex inline flowmeters measure flows of liquid, gas, and steam by measuring the rate at which vortices are alternately shed from a bluff body; this rate has been shown to be directly proportional to the flow velocity.
As flow passes a bluff body in the stream, vortices create pressure differentials which are measured by a piezoelectric crystal sensor, which converts these pulses into electrical signals. The meter uses an all-welded sensor design to create a strong unit and minimize potential leakage.
The AX Series can be configured to measure anything from simple volumetric flow of liquids and saturated steam up through multivariable measurements, including mass flow rate, pressure, temperature and density of liquids and steam.
Insertion style vortex meters measure fl ow by detecting the local velocity at a strategically located position within the pipe. Using local velocity, calculated by measuring the rate at which vortices are alternately shed from a bluff body within the sensor, the AX2300 uses parameters such as fluid type, pipe size, and Reynolds number to calculate accurate measurements.
Fluke Calibration on How to Calibrate an RTD Using a Dry block Calibrator Web...Transcat
This document provides guidance on how to calibrate an RTD (resistance temperature detector) using a dry-block calibrator. It discusses potential sources of error from a dry-block like immersion depth, stem conduction, contact issues and temperature non-uniformity. It recommends fully immersing probes, maintaining consistent depths between the RTD and reference probe, and accounting for uncertainties. The document then walks through calculating uncertainties, addressing odd shaped probes, temperature ranges, and provides an example of a three-point RTD calibration using a dry-block and software.
The HY-OPTIMA™ 730 is a solid-state sensor configured to operate in background gas streams having carbon monoxide concentrations up to 100 ppm, hydrogen sulfide stream concentrations up to 1000 ppm, up to 95% relative humidity, and temperatures up to 100ºC.
Intrinsically Safe ATEX, unsurpassed certified oxygen analyser for all hazardous areas. The EC91 Process Oxygen Transmitter will detect levels of oxygen as low as 1ppm, up to higher percent levels and can be used on most industrial gases and atmospheres.
Flowfit cca250 endress+hauser datasheet-flow assembly for chlorine and p h:or...ENVIMART
Flowfit cca250 endress+hauser datasheet-flow assembly for chlorine and p h:orp sensors - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
QCBox-ATEX : a photoacoustic spectrometer dedicated to process monitoring
The QCBox-ATEX is specifically tailored to monitor On-line Processes in the chemical and petrochemical industries. The quality of the materials is of prime importance to those industries and defines the commercial value of the products. The detection of impurities, pollutants or corroding compounds is paramount in adjusting the process and optimizing reactions. The QCBox-ATEX allows for the detection of minute traces of any contaminating gases in any type of gas streams.
GE Webinar: Oxygen Measurement for Chemical & Fuel Storage SafetyTranscat
This webinar will explore:
-The parameters needed for an explosion or fire to occur
-Identifying "Lower Explosive Limit"
-Measuring oxygen concentration using Thermoparamagnetic Oxygen sensors
-Application considerations and case studies
The HY-OPTIMA™ 740 is a solid-state sensor configured to operate in background gas streams having carbon monoxide concentrations up to 20% by volume, hydrogen sulfide stream concentrations up to 10% by volume, up to 95% relative humidity, and temperatures up to 100ºC.
H2scan’s HY-ALERTA™ 600 Fixed Area Hydrogen Monitor will provide hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit
The document describes several gas monitoring devices:
- The 4 Channel Gas Monitor is a wall-mounted unit that monitors up to 4 toxic gases, combustible gases, or oxygen levels with displays and alarms.
- The Multichannel Gas Monitor is a rack-mounted system compatible with up to 16 sensors for monitoring multiple gas channels.
- The IR80 CO2 Gas Monitor is a standalone or networked monitor for carbon dioxide levels with alarms and calibration assistance.
Allwin21 Corp. was formed in 2000 with a focus on professionally providing Rapid Thermal Process, Plasma Asher Strip / Descum, Plasma Etch/RIE, Sputter Deposition and Metal Film Metrology high-tech semiconductor equipment, services and technical support in Semiconductor III-V, MEMS, Biomedical, Nanotechnology, Solar, Battery & LED industries. We endeavor to be a leader in our product lines.
We focus on extending product lifecycle, providing solutions, and engineering enhancements to many production proven semiconductor process equipment most directly related to III-V processing. These semiconductor equipment have been used in production and R&D since the 1990′s. They have proven processes and research. Allwin21 Corp. customizes these systems with Allwin21′s comparable integrated process control system with PC, solid robotic wafer transfer system, and new critical components. This is to achieve the goal of giving our customers a production edge, with right cost, and without having to worry about obsolete parts.
The PT205-LEL is a combustible hydrocarbon sensor that uses a catalytic bead sensor to detect combustible vapors from 0-100% LEL. It has a microprocessor-based modular design that provides a 4-20mA output and LED status indicator. The sensor is approved for use in hazardous locations and has a response time of less than 10 seconds for 100% LEL methane gas.
Datasheet Fluke 726. Hubungi PT. Siwali Swantika 021-45850618PT. Siwali Swantika
Datasheet Fluke Precision Multifunction Process Calibrator. Informasi lebih detail hubungi PT. Siwali Swantika, Jakarta Office : 021-45850618 atau Surabaya Office : 031-8421264
AccuThermo AW 820 Long Time Rapid Thermal Anneal EquipmentPeter Chen
The document describes the AccuThermo AW820 rapid thermal processing system. It provides short heating periods from 1-900 seconds at precisely controlled temperatures using high intensity visible radiation. Key features include long steady time capability, advanced software for real-time control, consistent wafer-to-wafer repeatability, and fast heating and cooling rates. It is a production-proven standalone system for applications such as semiconductor manufacturing, compound semiconductors, MEMS, and more.
Spec sheet Cemtek Model 1000 Oxygen MonitorBrian Gilmore
Key Features:
• Modular probe design with blowdown ideal for high dust,
corrosive applications
• FM Approved
• Ease of maintenance with no probe removal to replace
element
• Combustion efficiency mode available as option
• Remote control of calibration and blowdown routines via
digital inputs
• Detector sensor replacement and maintenance is half
the cost of equivalent competitive products
https://www.linkedin.com/pub/brian-gilmore/4/705/238
Highly responsive touchscreen for ease of operation The model 1077L Viscometer+ features an ultra responsive projective capacitive touchscreen which has a unique IECEx & ATEX Zone 1 IIC rating without the need for air purge.
The Spectrum SB1000 is a self-contained portable gas analyzer suited for a wide range of applications including waste incineration, glass production, refinery processes, and more. It uses non-dispersive infrared absorption technology to selectively and sensitively measure gases with excellent repeatability across a huge range of options. The onboard electronics simplify operation while calibration and display can be customized for easy integration. It provides reliable measurement with proven design and a single AC power supply.
The new Fluke 725 Multifunction Process
Calibrator is a powerful yet easy-to-use field
calibrator. Use the measure and source functions
to test and calibrate almost any process
parameter.
Series RHPLC Wall Mount Humidity/Temperature TransmitterDwyer Instruments
The Series RHPLC Wall Mount Humidity/Temperature Transmitter is a compact economical sensor for the building automation market space. The stylish housing is well vented to provide air flow across the sensor to improve measurement accuracy. Each unit utilizes a capacitive polymer sensing element to deliver a proportional analog output. A combination humidity and temperature model can be configured with current, voltage, RTD, or thermistor output. A wide selection of passive RTD or thermistor temperature sensors are available in this series.
Learn more or order at www.dwyer-inst.com/Product/AirQuality/Humidity-TemperatureTransmitters/SeriesRHPLC
The document provides technical specifications for the Liquicap T FMI21, a two-rod capacitive probe for continuous level measurement in liquids. It can measure levels in tanks of various materials from 6 to 98 inches in length and operates independently of tank geometry. The probe measures the capacitance between its two rods to determine the liquid level and transmits a 4-20 mA signal corresponding to the percentage of probe submerged.
The document provides product information for the Cerabar T PMP131 pressure transmitter including:
- It measures absolute and gauge pressures from 0-25 bar using a 4-20mA output signal.
- Key features include long term stability, accuracy of <0.5%, and IP65/IP68 protection.
- It has common process connections including ANSI 1/2" and 1/4" and can operate from -25°C to +70°C.
- Accessories include displays for mounting in the field and it is available from $242 for small quantities.
Meet the demanding needs of high-purity water measurements and high-acid cation exchange applications with the Thermo Scientific™ Orion™ 2111XP Sodium Analyzer. This system offers unmatched reliability in analyzing critical sample streams throughout the power/steam generation and industrial water industry. It is an all-in-one system from one of the most trusted names in sodium monitoring.
Peak Scientific an Peak Gas Generation company supplies Nitrogen, Hydrogen, oxygen and compressed air to laboratories and businesses with global support. This presentation provides information specific for the use of Hydrogen gas generators for the oil and gas industry and use in Gas chromatography (GC). We explain the safety features and benefits of a generator over alternative methods of gas delivery, certifications and ASTM methods that support H2 as a carrier gas for GC. We welcome any questions or enquiries to anzsupport@peakscientific.com
AccuThermo AW 810 Rapid Thermal Anneal EquipmentPeter Chen
The AccuThermo AW810 was derived from the AG Associates 610 production-proven design. Allwin21 Corp. is the exclusive manufacturer of the AG Associates Heatpulse 610 desktop atmospheric RTP (Rapid Thermal Processing) system. The system uses high intensity visible radiation to heat single wafer for short process periods of time at precisely controlled temperatures. The process periods are typically 1 600 seconds in duration, although periods of up to 9999 seconds can be selected. These capabilities, combined with the heating chamber's cold-wall design and superior heating uniformity, provide significant advantages over conventional furnace processing.
We fotograferen, scannen woningen, gebouwen, constructies voor vastgoedmakelaars, architecten, projectontwikkelaars, aannemers,...
Daarnaast maken we 360° scans, virtual tours, grondplannen, luchtfoto's met
drones, mapping en nog veel meer.
Diensten voor vastgoed
Standaard fotografie
3d scans
Virtual tours
2d vloerplannen
Drone foto -en videografie
Virtual staging
Nabewerken foto's
Vastgoed teaser videos
Diensten voor
constructies
Foto en video
3d scans
E57 files
Vloerplannen
Puntenwolken
Mesh bestanden
Trueplan
Luchtfoto's
en meer
XRF Based &Multi-Metals & Continuous Water Analyzer Xact920European Tech Serv
Process monitoring – feedback for water treatment may improve the efficiency of the treatment process – use fewer chemicals to achieve require effluent emission limits
Measurement of Se, As for compliance with Steam Electric Generating Effluent Guidelines
Monitoring of treatment of wastewater by biological based treatment systems
Measurement of Corrosion Products (e.g. Fe, Ni, Cr and Mn) to improve operating efficiency
Measurement of Elements in Nuclear Power Plant Applications (e.g. Pb, Cu, Fe)
Reduce laboratory analysis costs
On-line, in-situ, and at-line monitoring of batch and continuous processes
Displays up to 15 properties at once and measures up to 30 properties per stream
Optical multiplexing capabilities provide analysis of up to 16 process streams using fiber optic or extractive stream switching
Utilizes process-proven ANALECT® Diamond 20™ Transept™ optical head
SpectraRTS™ software engineered exclusively for on-line monitoring, allowing use by engineers, maintenance personnel, and chemists
All ANALECT® lab and on-line systems share core optical technology, allowing instrument-to-instrument calibration transfers
The FROG-5000™ is a portable gas chromatograph (GC) that identifies multiple target volatile organic compounds (VOC) in water, soil, and air. The FROG-5000™ detects chemicals as volatile as vinyl chloride to semi-volatile organics such as naphthalene with lab quality results.
Featuring a MEMS (micro electro-mechanical systems), the FROG-5000™ has an integrated heater for temperature ramp chromatography – ramping the temperature reduces the analysis time and aids in the separation of late eluting compounds. These components combined with an internal PID identify VOCs in ambient air at concentrations as low as 1 part per billion.
Continuous analysis:
Continuous analysis of aerosols on filters for optical and thermal analysis
OC/EC determination:
Real time/online TC/BC/EC/OC and Brc analysis in combination with our Aethalometer AE33
Ease of Use:
No fragile glassware, no catalyst, no gas supplies needed
Rugged, Reliable, automatic:
35 years of published performance, rugged, all-steel construction, unattended operation – 1 month minimum
At the core of our technology are our next‑generation air quality monitors - the Clarity Node and Node-S. These nimble monitors are configured on our web-based deployment tool and installed in a matter of minutes. Hundreds to thousands of devices work together to form a scalable network of high density air quality measurement points.
At the core of our technology are our next‑generation air quality monitors - the Clarity Node and Node-S. These nimble monitors are configured on our web-based deployment tool and installed in a matter of minutes. Hundreds to thousands of devices work together to form a scalable network of high density air quality measurement points.
At the core of our technology are our next‑generation air quality monitors - the Clarity Node and Node-S. These nimble monitors are configured on our web-based deployment tool and installed in a matter of minutes. Hundreds to thousands of devices work together to form a scalable network of high density air quality measurement points.
At the core of our technology are our next‑generation air quality monitors - the Clarity Node and Node-S. These nimble monitors are configured on our web-based deployment tool and installed in a matter of minutes. Hundreds to thousands of devices work together to form a scalable network of high density air quality measurement points.
The Mi3 is a turnkey solution for automotive emission testing that features the world's fastest particle sensor. It provides accurate real-time data, reliable measurements in all environments, and ensures measurements meet emission regulations standards. The Mi3 requires little maintenance due to its low-maintenance particle sensor and self-diagnostics. It can integrate seamlessly with existing emission test infrastructure through various connection options.
THE GAS CHROMATOGRAPHIC REVOLUTION
FOR ENVIRONMENTAL MONITORING
PyxisGC BTEX is the first and unique gaschromatograph "carrier gas free" for remote BTEX monitoring
in ambient air. PyxisGC BTEX is manufactured by Pollution Analytical Equipment in compliance with
EN14662-3:2015.
"BTEX ambient air analysis: sources, regulations, technologies for controls"European Tech Serv
"BTEX ambient air analysis: sources, regulations, technologies for
controls"
In collaboration with The Council for Research and Experimentation in Agriculture at the Puglia
Regional Environmental Protection Agency (ARPA)
The M1000 operates according to the diffusion principle. The monitor is mounted on a flange which is located at the top of the silo or bin. The gas in the atmosphere of the silo diffuses into the oxygen sensor. Since there is no positive movement of chemical powder to the sensor the sampling gas will not block filters and tubing. The right design and choice of components ensures a long term maintenance free operation.
H2scan’s HY-ALERTA™ 600 Fixed Area Hydrogen Monitor will provide hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit
H2scan’s HY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit.
H2scan’s HY-ALERTA™ 2600 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s lower flammability limit.
Technology background HY-ALERTA SAFETY SYSTEMS – HY-ALERTA 2600European Tech Serv
H2scan’s HY-ALERTA™ 2600 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s lower flammability limit.
H2scan’s 2620 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit. The monitor is designed for either ceiling or wall mount. H2scan’s hydrogen-specific sensor technology has no cross sensitivity to other combustible gases, thus eliminating false positive alarms and ensuring safety system reliability.
The document describes a solid-state hydrogen sensor that uses both resistor and capacitor circuits to detect hydrogen from 15 ppm to 100% by volume. It has a palladium-nickel alloy film that provides stability and a proprietary coating that allows operation in harsh environments. An on-chip temperature control loop compensates for external fluctuations, and the sensor can operate in nitrogen, oxygen, and other inert gas backgrounds as well as multi-component and varying gas and liquid streams.
Optimizing Post Remediation Groundwater Performance with Enhanced Microbiolog...Joshua Orris
Results of geophysics and pneumatic injection pilot tests during 2003 – 2007 yielded significant positive results for injection delivery design and contaminant mass treatment, resulting in permanent shut-down of an existing groundwater Pump & Treat system.
Accessible source areas were subsequently removed (2011) by soil excavation and treated with the placement of Emulsified Vegetable Oil EVO and zero-valent iron ZVI to accelerate treatment of impacted groundwater in overburden and weathered fractured bedrock. Post pilot test and post remediation groundwater monitoring has included analyses of CVOCs, organic fatty acids, dissolved gases and QuantArray® -Chlor to quantify key microorganisms (e.g., Dehalococcoides, Dehalobacter, etc.) and functional genes (e.g., vinyl chloride reductase, methane monooxygenase, etc.) to assess potential for reductive dechlorination and aerobic cometabolism of CVOCs.
In 2022, the first commercial application of MetaArray™ was performed at the site. MetaArray™ utilizes statistical analysis, such as principal component analysis and multivariate analysis to provide evidence that reductive dechlorination is active or even that it is slowing. This creates actionable data allowing users to save money by making important site management decisions earlier.
The results of the MetaArray™ analysis’ support vector machine (SVM) identified groundwater monitoring wells with a 80% confidence that were characterized as either Limited for Reductive Decholorination or had a High Reductive Reduction Dechlorination potential. The results of MetaArray™ will be used to further optimize the site’s post remediation monitoring program for monitored natural attenuation.
Evolving Lifecycles with High Resolution Site Characterization (HRSC) and 3-D...Joshua Orris
The incorporation of a 3DCSM and completion of HRSC provided a tool for enhanced, data-driven, decisions to support a change in remediation closure strategies. Currently, an approved pilot study has been obtained to shut-down the remediation systems (ISCO, P&T) and conduct a hydraulic study under non-pumping conditions. A separate micro-biological bench scale treatability study was competed that yielded positive results for an emerging innovative technology. As a result, a field pilot study has commenced with results expected in nine-twelve months. With the results of the hydraulic study, field pilot studies and an updated risk assessment leading site monitoring optimization cost lifecycle savings upwards of $15MM towards an alternatively evolved best available technology remediation closure strategy.
RoHS stands for Restriction of Hazardous Substances, which is also known as t...vijaykumar292010
RoHS stands for Restriction of Hazardous Substances, which is also known as the Directive 2002/95/EC. It includes the restrictions for the use of certain hazardous substances in electrical and electronic equipment. RoHS is a WEEE (Waste of Electrical and Electronic Equipment).
Improving the viability of probiotics by encapsulation methods for developmen...Open Access Research Paper
The popularity of functional foods among scientists and common people has been increasing day by day. Awareness and modernization make the consumer think better regarding food and nutrition. Now a day’s individual knows very well about the relation between food consumption and disease prevalence. Humans have a diversity of microbes in the gut that together form the gut microflora. Probiotics are the health-promoting live microbial cells improve host health through gut and brain connection and fighting against harmful bacteria. Bifidobacterium and Lactobacillus are the two bacterial genera which are considered to be probiotic. These good bacteria are facing challenges of viability. There are so many factors such as sensitivity to heat, pH, acidity, osmotic effect, mechanical shear, chemical components, freezing and storage time as well which affects the viability of probiotics in the dairy food matrix as well as in the gut. Multiple efforts have been done in the past and ongoing in present for these beneficial microbial population stability until their destination in the gut. One of a useful technique known as microencapsulation makes the probiotic effective in the diversified conditions and maintain these microbe’s community to the optimum level for achieving targeted benefits. Dairy products are found to be an ideal vehicle for probiotic incorporation. It has been seen that the encapsulated microbial cells show higher viability than the free cells in different processing and storage conditions as well as against bile salts in the gut. They make the food functional when incorporated, without affecting the product sensory characteristics.
Kinetic studies on malachite green dye adsorption from aqueous solutions by A...Open Access Research Paper
Water polluted by dyestuffs compounds is a global threat to health and the environment; accordingly, we prepared a green novel sorbent chemical and Physical system from an algae, chitosan and chitosan nanoparticle and impregnated with algae with chitosan nanocomposite for the sorption of Malachite green dye from water. The algae with chitosan nanocomposite by a simple method and used as a recyclable and effective adsorbent for the removal of malachite green dye from aqueous solutions. Algae, chitosan, chitosan nanoparticle and algae with chitosan nanocomposite were characterized using different physicochemical methods. The functional groups and chemical compounds found in algae, chitosan, chitosan algae, chitosan nanoparticle, and chitosan nanoparticle with algae were identified using FTIR, SEM, and TGADTA/DTG techniques. The optimal adsorption conditions, different dosages, pH and Temperature the amount of algae with chitosan nanocomposite were determined. At optimized conditions and the batch equilibrium studies more than 99% of the dye was removed. The adsorption process data matched well kinetics showed that the reaction order for dye varied with pseudo-first order and pseudo-second order. Furthermore, the maximum adsorption capacity of the algae with chitosan nanocomposite toward malachite green dye reached as high as 15.5mg/g, respectively. Finally, multiple times reusing of algae with chitosan nanocomposite and removing dye from a real wastewater has made it a promising and attractive option for further practical applications.
Wildlife-AnIntroduction.pdf so that you know more about our environment
H2700as solid state sensor
1. HY-OPTIMATM
2700AS Process Hydrogen Analyzing System
HY-OPTIMA
TM
is a registered Trademark of H2scan 27215 Turnberry Lane, Unit A, Valencia CA., 91355
Specifications subject to change without prior notice Tel: 661-775-9575, Fax: 661-775-9515
90000085 R0 Email: sales@h2scan.com, Website: www.h2scan.com
Sensor Performance
Hydrogen Sensitivity Range:
0.5% to 100% hydrogen by volume at 1 ATM
Response Time: T90 < 30 sec
Ingress Protection: IP64 capable
Recommended Verification Interval: 90 days
Product Life Expectancy: 10 years
Accuracy(*):
± 0.3% absolute for 0.5 to 10% H2
± 1.0% absolute for 10 to 100% H2
Drift/week:
± 0.2% absolute for 0.5 to 10% H2
± 0.4% absolute for 10 to 100% H2
Repeatability:
± 0.2% absolute for 0.5 to 10% H2
± 0.4% absolute for 10 to 100% H2
Linearity:
0.2% absolute for 0.5-10% H2
0.4% absolute for 10-100% H2
Description
H2scan’s HY-OPTIMATM
Model 2700AS Process Hydrogen Analyzing System provides a complete solution for
process hydrogen measurement in refineries, chemical plants, air separation units and industrial gas manufacturing
plants. The system implements H2scan’s hydrogen specific analyzer in a NEMA 4X enclosure with the necessary
sample conditioning components to enable operation over a broad spectrum of process conditions.
Interface Options
Analog Output: 4 to 20mA
Serial Communication: RS232/422
Two built-in relays
Fault relay
System Operating Conditions
Inlet Conditions:
Inlet pressure: 30 to 510 PSIG*
Process temperature: -20 to 100ºC*
Operating Voltage: 110VAC/230VAC
Enclosure Classification: NEMA 4X
Sample Flow Rate: .8 to 1 SLPM*
Accessories*
Vortex Cooler
Enclosure Heater: 200 Watts, 1.74 Amps at 115 VAC
Flow Meter
Pressure Transducer
Typical Dimensions*
Length: 24’’
Height: 24’’
Width: 10’’
Support & Warranty
1 year all parts and labor
Field support available upon request
Series 2700 Certification
UL Class1 Div1 Groups B,C,D
ATEX Ex Proof Ex d IIB + H2 T4 Gb
* Can be customized per customer requirements.
2. HY-OPTIMATM
2700AS Process Hydrogen Analyzing System
HY-OPTIMA
TM
is a registered Trademark of H2scan 27215 Turnberry Lane, Unit A, Valencia CA., 91355
Specifications subject to change without prior notice Tel: 661-775-9575, Fax: 661-775-9515
90000085 R0 Email: sales@h2scan.com, Website: www.h2scan.com