Feam EJB INX Zone 1 & Zone 2 Enclosures (Atex) Hazardous Area
Hazardous Area Enclosures:
Zone 1 & Zone 2 (Gases)
Zone 21 & Zone 22 (Dusts)
Hazardous Area Classification
Group: II Category: 2G - 2D
Hazardous Area Enclosure Approvals
ATEX
II 2 G Ex db IIB+H2 T6...T3
II 2 G Ex db [ia/ib] IIB+H2 T6...T3
II 2 D Ex tb IIIC T85ºC...T150ºC
IECEx
Ex db IIB+H2 T6...T3
Ex db [ia/ib] IIB+H2 T6...T3
Ex tb IIIC T85ºC...T150ºC
INMETRO
Ex db IIB+H2 T6...T3
Ex db [ia/ib] IIB+H2 T6...T3
Ex tb IIIC T85ºC...T150ºC
GOST-R GOST-K
1 Ex d IIB+H2 T6
1 Ex d [ia/ib] IIB+H2 T6
Ex tD A21 T85ºC...T150ºC
1 Ex d IIB+H2 U
NEC505
USL: Class 1, Zone 1, AEx db IIB+H2
Zone 21 AEx tb IIIC T85ºC...T150ºC
CNL: Exd IIB+H2; Class II, Groups E, F and G
FEAM EJB INX Enclosures - Mechanical Features
Stainless steel AISI-316 L body/cover
Stainless steel AISI-316 L screws
Stainless steel AISI-316 L/aluminium internal mounting plate
Stainless steel AISI-316 L fixing lugs - stainless steel stirrups sp.10mm (EJB71/73 and EJB91/93)
Hinges welded on cover and body
Opening handle - insulating material fixed on cover by stainless steel screws
FEAM enclosures are suitable for Hazardous Area Enclosures Zone 1 & Zone 2. T&D are distributors for the FEAM range of Hazardous Area Enclosures for installation in potentially explosive atmospheres - FEAM enclosures are specified for hazardous areas Zone 1 and Zone 2 (Gases) with international certifications according to ATEX, Inmetro, GOST-R, GOST-K, IECEx and CE.
ATEX, IECEx, Inmetro, GOST-R, GOST-K, NEC505 Certified Enclosures.
Hazardous Area Enclosures : Zone 1 & Zone 2 (Gases) - Zone 21 & Zone 22 (Dusts).
Hazardous Area Classification
Group: II Category: 2G - 2D
T&D are distributors for the FEAM range of Hazardous Area Lighting for installation in potentially explosive atmospheres - FEAM lighting is specified for hazardous areas Zone 1 and Zone 2 (Gases) with international certifications according to ATEX, Inmetro, GOST-R, GOST-K, IECEx and CE.
FEAM enclosures are suitable for Hazardous Area Enclosures Zone 1 & Zone 2. T&D are distributors for the FEAM range of Hazardous Area Enclosures for installation in potentially explosive atmospheres - FEAM enclosures are specified for hazardous areas Zone 1 and Zone 2 (Gases) with international certifications according to ATEX, Inmetro, GOST-R, GOST-K, IECEx and CE.
ATEX, IECEx, Inmetro, GOST-R, GOST-K, NEC505 Certified Enclosures.
Hazardous Area Enclosures : Zone 1 & Zone 2 (Gases) - Zone 21 & Zone 22 (Dusts).
Hazardous Area Classification
Group: II Category: 2G - 2D
T&D are distributors for the FEAM range of Hazardous Area Lighting for installation in potentially explosive atmospheres - FEAM lighting is specified for hazardous areas Zone 1 and Zone 2 (Gases) with international certifications according to ATEX, Inmetro, GOST-R, GOST-K, IECEx and CE.
ASCO Solenoid Valves Catalog with detailed specifications to order with complete correct sizes and configuration choices. For reference only. To order, contact Carotek.com
SOR® is a manufacturer of high-quality pressure and tempreature switches for industrial service. They serve a global market of oil and gas, chemical, petrochemical, and power industries through a network of independent sales representatives. Their products are suitable for a broad range of safety systems, control processes, and related applications.
ASCO Solenoid Valves Catalog with detailed specifications to order with complete correct sizes and configuration choices. For reference only. To order, contact Carotek.com
SOR® is a manufacturer of high-quality pressure and tempreature switches for industrial service. They serve a global market of oil and gas, chemical, petrochemical, and power industries through a network of independent sales representatives. Their products are suitable for a broad range of safety systems, control processes, and related applications.
Rotronic Data Sheet HygroFlex Ex - protected humidity and temperature transmitter. Reliable measurement under extreme conditions. Info lebih lanjut hubungi Siwali Swantika, Jakarta : 021-45850618 | Surabaya : 031-8421264. Distributor Rotronic di Indonesia
Isolation Procedures for Safe Working on Electrical Systems and Equipment by the JIB | solation Procedures for Safe Working on Electrical Systems and Equipment
This chart shows the safe isolation procedure that you should use when working on electrical systems and equipment.
You'll receive a printed copy of this from your Training Provider, but it's also here as a handy reference to keep electronically.
THE RULES OF SAFE ISOLATION ARE:
Obtain permission to start work (a Permit may be required in some situations)
Identify the source(s) of supply using an approved voltage indicator or test lamp
Prove that the approved voltage indicator or test lamp is functioning correctly
Isolate the supply(s)
Secure the isolation
Prove the system/equipment is DEAD using an approved voltage indicator or test lamp
Prove that the approved voltage indicator or test lamp is functioning correctly
Put up warning signs to tell other people that the electrical installation has been isolated
Once the system/equipment is proved DEAD, work can begin
Uploaded by THORNE & DERRICK LV HV Jointing, Earthing, Substation & Electrical Eqpt | Explosive Atmosphere Experts & ATEX IECEx.
THORNE & DERRICK based in the UK are international distributors of LV, MV & HV Cable Installation, Jointing, Substation & Electrical Equipment.
Since 1985, T&D have established an international reputation based on SERVICE | INTEGRITY | TRUST.
Contact us for 3M, ABB, Alroc, AN Wallis, CATU, Cembre, Centriforce, CMP, CSD, Elastimold, Ellis Patents, Emtelle, Euromold, Filoform , Furse, Lucy Electric & Zodion, Nexans, Pfisterer, Polypipe, Prysmian, Roxtec, Sicame, WT Henley.
UiPath Test Automation using UiPath Test Suite series, part 3DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 3. In this session, we will cover desktop automation along with UI automation.
Topics covered:
UI automation Introduction,
UI automation Sample
Desktop automation flow
Pradeep Chinnala, Senior Consultant Automation Developer @WonderBotz and UiPath MVP
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
Transcript: Selling digital books in 2024: Insights from industry leaders - T...BookNet Canada
The publishing industry has been selling digital audiobooks and ebooks for over a decade and has found its groove. What’s changed? What has stayed the same? Where do we go from here? Join a group of leading sales peers from across the industry for a conversation about the lessons learned since the popularization of digital books, best practices, digital book supply chain management, and more.
Link to video recording: https://bnctechforum.ca/sessions/selling-digital-books-in-2024-insights-from-industry-leaders/
Presented by BookNet Canada on May 28, 2024, with support from the Department of Canadian Heritage.
GraphRAG is All You need? LLM & Knowledge GraphGuy Korland
Guy Korland, CEO and Co-founder of FalkorDB, will review two articles on the integration of language models with knowledge graphs.
1. Unifying Large Language Models and Knowledge Graphs: A Roadmap.
https://arxiv.org/abs/2306.08302
2. Microsoft Research's GraphRAG paper and a review paper on various uses of knowledge graphs:
https://www.microsoft.com/en-us/research/blog/graphrag-unlocking-llm-discovery-on-narrative-private-data/
Software Delivery At the Speed of AI: Inflectra Invests In AI-Powered QualityInflectra
In this insightful webinar, Inflectra explores how artificial intelligence (AI) is transforming software development and testing. Discover how AI-powered tools are revolutionizing every stage of the software development lifecycle (SDLC), from design and prototyping to testing, deployment, and monitoring.
Learn about:
• The Future of Testing: How AI is shifting testing towards verification, analysis, and higher-level skills, while reducing repetitive tasks.
• Test Automation: How AI-powered test case generation, optimization, and self-healing tests are making testing more efficient and effective.
• Visual Testing: Explore the emerging capabilities of AI in visual testing and how it's set to revolutionize UI verification.
• Inflectra's AI Solutions: See demonstrations of Inflectra's cutting-edge AI tools like the ChatGPT plugin and Azure Open AI platform, designed to streamline your testing process.
Whether you're a developer, tester, or QA professional, this webinar will give you valuable insights into how AI is shaping the future of software delivery.
Dev Dives: Train smarter, not harder – active learning and UiPath LLMs for do...UiPathCommunity
💥 Speed, accuracy, and scaling – discover the superpowers of GenAI in action with UiPath Document Understanding and Communications Mining™:
See how to accelerate model training and optimize model performance with active learning
Learn about the latest enhancements to out-of-the-box document processing – with little to no training required
Get an exclusive demo of the new family of UiPath LLMs – GenAI models specialized for processing different types of documents and messages
This is a hands-on session specifically designed for automation developers and AI enthusiasts seeking to enhance their knowledge in leveraging the latest intelligent document processing capabilities offered by UiPath.
Speakers:
👨🏫 Andras Palfi, Senior Product Manager, UiPath
👩🏫 Lenka Dulovicova, Product Program Manager, UiPath
UiPath Test Automation using UiPath Test Suite series, part 4DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 4. In this session, we will cover Test Manager overview along with SAP heatmap.
The UiPath Test Manager overview with SAP heatmap webinar offers a concise yet comprehensive exploration of the role of a Test Manager within SAP environments, coupled with the utilization of heatmaps for effective testing strategies.
Participants will gain insights into the responsibilities, challenges, and best practices associated with test management in SAP projects. Additionally, the webinar delves into the significance of heatmaps as a visual aid for identifying testing priorities, areas of risk, and resource allocation within SAP landscapes. Through this session, attendees can expect to enhance their understanding of test management principles while learning practical approaches to optimize testing processes in SAP environments using heatmap visualization techniques
What will you get from this session?
1. Insights into SAP testing best practices
2. Heatmap utilization for testing
3. Optimization of testing processes
4. Demo
Topics covered:
Execution from the test manager
Orchestrator execution result
Defect reporting
SAP heatmap example with demo
Speaker:
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
PHP Frameworks: I want to break free (IPC Berlin 2024)Ralf Eggert
In this presentation, we examine the challenges and limitations of relying too heavily on PHP frameworks in web development. We discuss the history of PHP and its frameworks to understand how this dependence has evolved. The focus will be on providing concrete tips and strategies to reduce reliance on these frameworks, based on real-world examples and practical considerations. The goal is to equip developers with the skills and knowledge to create more flexible and future-proof web applications. We'll explore the importance of maintaining autonomy in a rapidly changing tech landscape and how to make informed decisions in PHP development.
This talk is aimed at encouraging a more independent approach to using PHP frameworks, moving towards a more flexible and future-proof approach to PHP development.
Designing Great Products: The Power of Design and Leadership by Chief Designe...
Feam EJB INX Zone 1 & Zone 2 Enclosures (Atex) Hazardous Area
1. ENCLOSURES
Explosion Proof Electrical Equipment
Ex Enclosures
EJB INX
EJB inx
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
ATEX 94/9/EC
II 2 G Ex db IIB+H2 T6…T3
II 2 G Ex db [ia ib]
IIB+H2 T6…T3
II 2 D Ex tb IIIC T85°C…T150°C
EXECUTION
*TERMINAL BOARD
IEC Ex
INMETRO
Ex db IIB+H2 T6…T3
Ex db [ia/ib] IIB+H2 T6…T3
Ex tb IIIC T85°C…T150°C
GOST-R (RTR/RTN)/K
NEC 505
Ex db IIB+H2 T6…T3
Ex db [ia/ib] IIB+H2 T6…T3
Ex tb IIIC T85°C…T150°C
1 Ex d IIB+H2 T6
1 Ex d [ia/ib] IIB+H2 T6
Ex tD A21 T85°C…t150°C
1Ex d IIB+H2 U
USL: Class 1, Zone 1, AEx db IIB+H2
Zone 21, AEx tb IIIC T85°C…T150°C
CNL: Exd IIB+H2; class II,
groups E, F and G
*POWER UNITS
ATEX 94/9/EC
IEC Ex
II 2 G Ex td IIB+H2 T6…T3
II 2 D Ex tb IIIC T85°C…150°C
EXECUTION
INMETRO
Ex db IIB+H2 T6…T3
Ex db [ia/ib] IIB+H2 T6…T3
Ex tb IIIC T85°C…T150°C
GOST-R (RTR/RTN)/K
NEC 505
Ex db IIB+H2 T6…T3
Ex db [ia/ib] IIB+H2 T6…T3
Ex tb IIIC T85°C…T150°C
1 Ex d IIB+H2 T6
1 Ex d [ia/ib] IIB+H2 T6
Ex tD A21 T85°C…t150°C
1Ex d IIB+H2 U
USL: Class 1, Zone 1, AEx db IIB+H2
Zone 21, AEx tb IIIC T85°C…T150°C
CNL: Exd IIB+H2; class II,
groups E, F and G
*CONTROL AND SIGNALLING UNITS
ATEX 94/9/EC
IEC Ex
INMETRO
II 2 G Ex td IIB+H2 T6…T3
II 2 (1) G Ex db [ia IIA/B/C]
Ex db IIB+H2 T6…T3
IIB+H2 T6…T3 II 2 (2) G Ex db [ib Ex db [ia/ib] IIB+H2 T6…T3
IIA/B/C] IIB+H2 T6…T3 II 2 D Ex tb Ex tb IIIC T85°C…T150°C
IIIC T85°C…150°C
EXECUTION
GOST-R (RTR/RTN)/K
NEC 505
Ex db IIB+H2 T6…T3
Ex db [ia/ib] IIB+H2 T6…T3
Ex tb IIIC T85°C…T150°C
1 Ex d IIB+H2 T6
1 Ex d [ia/ib] IIB+H2 T6
Ex tD A21 T85°C…t150°C
1Ex d IIB+H2 U
USL: Class 1, Zone 1, AEx db IIB+H2
Zone 21, AEx tb IIIC T85°C…T150°C
CNL: Exd IIB+H2; class II,
groups E, F and G
* valid data for all execution
AMBIENT TEMP.
-60°C ÷ +130°C
-60°C ÷ +130°C
-60°C ÷ +130°C
-60°C ÷ +60°C
-60°C ÷ +130°C
IP66
IP66
IP66
IP66
IP66
INERIS 13ATEX0022X
IECEx BKI 09.0005
CEPEL 12.2139
POCC IT. ME92.B02924
-
EN 60079-0:2004;
EN 60079-1:2004;
EN 60079-11:2006;
EN 60079-31:2009
IEC 60079-0;
IEC 60079-1;
IEC 60079-11;
IEC 60079-31
PROTECTION
DEGREE
CERTIFICATE REF.
RULES OF
COMPLIANCE
ABNT NBR IEC 60079-0:2008; ГОСТ Р МЭК 60079-0:2011;
ABNT NBR IEC 60079-1:2009; ГОСТ Р МЭК 61241-0:2007;
ABNT NBR IEC 60529:2009
ГОСТ Р МЭК 61241-1:2004
NEC 505
Class I
ATEX / IECEx / GOST
Zone
0
1
2
X
20
X
21
22
X
X
Zone
0
UL 60079-0; UL 60079-1;
ISA 60079-31;
CAN/CSA C22.2 No. 60079-0:11;
CAN/CSA C22.2 No. 60079-1:11;
NEC 500
Class II
Class III
2
1
2
1
2
X
X
X
X
X
Class I
1
2
X
X
Division
1
Mechanical characteristics
Body & cover
Screws
Internal mounting plate
Fixing
Hinges
Opening handle
stainless steel AISI-316 L
stainless steel AISI-316 L
stainless steel AISI-316 L / aluminum
fixing lugs stainless steel AISI-316 L - stainless steel stirrups sp.10mm (EJB71/73 AND EJB91/93)
welded on cover and body
insulating material fixed on cover by stainless steel screws
On Request Accessories:
•External epoxy painting (any colours)
•Internal anticondensate painting orange RAL-2004
•O-Ring gaskets on cover
•Glass windows on cover
•Drain and breather valves
Since 1961
YOUR PARTNER FOR SAFETY
Feam Catalogue 03 - 1
2. Ex Enclosures
EJB INX Technical features
A
[mm]
B
[mm]
C
[mm]
EJB-11 INX
175
175
180
EJB-21 INX
EJB-22 INX
EJB-23 INX
EJB-30 INX
EJB-31 INX
EJB-51 INX
EJB-61 INX
EJB-63 INX
EJB-71 INX
EJB-73 INX
EJB-91 INX
EJB-93 INX
285
300
310
415
415
565
670
670
742
742
960
960
245
200
260
315
315
365
470
470
542
542
660
660
260
215
280
330
330
400
485
485
557
557
678
678
Reference details
D
[mm]
E
[mm]
F
[mm]
121
80
194
218
197
158
243
253
344
229
400
279
432
275
160
195
195
294
294
360
500
500
500
500
600
600
H
[mm]
165
80
230
188
238
290
290
335
437
437
580
580
640
640
A
G
[mm]
L
[mm]
INT. PLATE
X - Y [mm]
WEIGHT
[Kg]
DETAIL
122
177
152
117
180
190
290
180
335
210
360
200
115
115
100 - 100
11,00
A
215
230
247
335
335
480
590
590
630
630
843
843
175
130
195
235
235
280
390
390
430
430
543
543
180 - 140
180 - 100
200 - 160
325 - 225
325 - 225
460 - 260
560 - 360
560 - 360
590 - 390
590 - 390
758 - 448
758 - 448
32,00
38,00
40,00
53,00
62,00
110,00
152,00
140,00
280,00
200,00
618,00
573,00
A
A
A
A
A
A
A
A
A
A
A
A
C
E
A
B
HxL
S.r.l.
CUSTODIA tipo
ENCLOSURE type
Via M. Pagano, 3
I-20090 Trezzano s/N
ITALY
www.feam-ex.com
0722
II2 GD
year s/n
BKI 08 ATEX 019
V
Hz
Ex d IIB+H
Ta
A
2
T
W
Ex tD A21 IP66 T
VA
°C
NON APRIRE SOTTO TENSIONE
DO NOT OPEN WHILE ENERGIZED
Ad ogni apertura del coperchio
ripristinare il grasso ai siliconi.
accertarsi che le valvole di respirazione
e drenaggio siano sempre chiuse
Renew silicone grease every tyme
cover is opened. and make sure
that the drain and breather valves
are always closed.
11.00.88
G
D
EJB inx
CODE
F
EJB Indicative quantity of terminals and relevant section
CODE
SECT. 2,5
[sq/mm]
SECT. 6,0
[sq/mm]
SECT. 10,0
[sq/mm]
SECT. 16,0
[sq/mm]
SECT. 35,0
[sq/mm]
SECT. 50,0
[sq/mm]
SECT. 70,0
[sq/mm]
SECT. 240,0
[sq/mm]
INT. PLATE X - Y
[mm]
100 - 100
EJB-11 INX
12 x 1
8 x 1
6 x 1
4 x 1
2 x 1
-
-
-
EJB-21 INX
30 x 1
20 x 1
14 x 1
12 x 1
9 x 1
7 x 1
5 x 1
1 x 1
180 - 140
EJB-22 INX
30 x 1
20 x 1
14 x 1
12 x 1
9 x 1
7 x 1
5 x 1
1 x 1
180 - 100
EJB-23 INX
35 x 1
22 x 1
16 x 1
14 x 1
11 x 1
9 x 1
7 x 1
2x1
200 - 160
EJB-30 INX
52 x 2
32 x 2
24 x 2
20 x 2
14 x 2
12 x 1
8 x 1
4 x 1
325 - 225
EJB-31 INX
52 x 2
32 x 2
24 x 2
20 x 2
14 x 2
12 x 1
8 x 1
4 x 1
325 - 225
EJB-51 INX
80 x 2
46 x 2
36 x 2
30 x 2
22 x 2
18 x 2
16 x 1
6 x 1
460 - 260
560 - 360
EJB-61/63 INX
92 x 3
58 x 3
46 x 3
38 x 3
28 x 3
26 x 2
22 x 2
12 x 1
EJB-71/73 INX
110 x 3
70 x 3
56 x 3
46 x 3
34 x 3
28 x 2
24 x 2
12 x 1
590 - 390
EJB-91/93 INX
140 x 3
90 x 3
70 x 3
60 x 3
44 x 3
36 x 3
32 x 2
14 x 2
758 - 448
Since 1961
2 - Feam Catalogue 03
YOUR PARTNER FOR SAFETY
3. Ex Enclosures
EJB INX Glass Windows on Cover
WINDOW
CODE
ENCLOSURE CODE
DIMENSIONS
EJB-11
INX
EJB-21
INX
EJB-22
INX
EJB-23
INX
EJB-30/31
INX
EJB-51
INX
EJB-61/63 EJB-71/73 EJB-91/93
INX
INX
INX
A
[mm]
B
[mm]
DETAIL
F1
X
X
X
X
X
X
X
X
X
60
60
C
F2
-
X
X
X
X
X
X
X
X
75
75
C
F3
-
X
X
X
X
X
X
X
X
110
75
C
F4
-
X
X
X
X
X
X
X
-
150
75
C
F5
-
-
-
-
X
X
X
-
-
150
150
C
F6
-
-
-
-
-
X
X
-
-
300
75
C
-
-
-
-
-
X
X
-
-
300
150
C
-
-
-
-
-
-
X
-
-
300
300
C
F9
-
-
-
-
-
-
X
-
-
450
300
C
Reference details
EJB inx
F7
F8
Reference details
plate
B
C
A
S.r.l.
CUSTODIA tipo
ENCLOSURE type
Via M. Pagano, 3
I-20090 Trezzano s/N
ITALY
www.feam-ex.com
0722
II2 GD
year s/n
BKI 08 ATEX 019 Ta
V
Ex d IIB+H
Hz
A
2
T
Ex tD A21 IP66 T
W
VA
°C
NON APRIRE SOTTO TENSIONE
DO NOT OPEN WHILE ENERGIZED
Ad ogni apertura del coperchio
ripristinare il grasso ai siliconi.
accertarsi che le valvole di respirazione
e drenaggio siano sempre chiuse
Renew silicone grease every tyme
cover is opened. and make sure
that the drain and breather valves
are always closed.
11.00.88
PLATE X-Y
EJB INX Body and Cover Enclosures Drilling Layout
ENCLOSURE
CODE
EJB-11 INX
DRILLING AREA
A-B [mm]
100x60
EJB-21 INX
EJB-22 INX
EJB-23 INX
EJB-30 INX
EJB-31 INX
EJB-51 INX
EJB-61 INX
EJB-63 INX
EJB-71 INX
EJB-73 INX
EJB-91 INX
EJB-93 INX
200x90
215x130
215x105
320x65
320x150
460x155
550x250
550x130
570x270
570x160
745x290
745x145
QUANTITY ALLOWED ENTRIES FOR
size (from 1 to size 8)
1
2
3
4
5
6
7
8
3
2
2
1
1
-
10
15
11
13
28
44
72
36
90
40
112
48
7
11
8
7
18
27
50
29
55
26
84
42
5
8
6
5
14
24
36
18
46
22
65
29
3
6
4
5
11
20
32
16
39
18
55
22
2
6
3
4
8
12
21
14
32
14
40
10
2
3
3
3
6
10
21
7
21
12
28
11
1
2
2
3
6
14
5
15
7
23
9
DRILLING AREA
C-D [mm]
100x60
1
1
2
3
8
4
10
4
14
5
160x90
110x130
165x105
225x65
225x150
255x155
350x250
350x130
370x270
370x160
440x290
440x145
QUANTITY ALLOWED ENTRIES FOR
size (from 1 to size 8)
1
2
3
4
5
6
7
8
3
2
2
1
1
-
8
9
9
9
20
24
48
24
59
26
70
30
5
5
6
5
12
15
30
17
35
18
42
24
4
5
6
4
9
12
24
12
28
14
35
21
3
4
5
3
8
11
20
10
25
12
35
14
2
2
2
3
6
6
12
8
21
8
24
12
1
1
2
2
5
6
12
4
12
11
18
7
1
1
1
2
3
8
3
10
4
13
5
1
1
1
2
6
3
6
2
8
3
Reference details
wall DRILLING AREA
C
D
B
A
Since 1961
YOUR PARTNER FOR SAFETY
Feam Catalogue 03 - 3
4. Ex Enclosures
EJB INX Body and Cover Enclosures Drilling Layout
Reference details
ENCLOSURE
CODE
DRILLING AREA
E-F [mm]
120x120
6
EJB-21 INX
200x155
12
EJB-22 INX
200x100
12
EJB-23 INX
215x165
16
EJB-30 INX
305x205
30
EJB-31 INX
305x205
30
EJB-51 INX
465x265
54
EJB-61 INX
575x370
56
EJB-63 INX
575x370
56
EJB-71 INX
590x390
48
EJB-73 INX
590x390
48
EJB-91 INX
800x500
54
EJB-93 INX
800x500
F
54
E
EJB-11 INX
EJB inx
Cover DRILLING AREA
MAX OPERATORS PERMITTED
EJB INX Threads comparation table
size
UNI 6125
ISO 228/1
ASA B2.1
ISO 965/I
1
GK 1/2”
G 1/2”
1/2” NPT
M20
2
GK 3/4”
G 3/4”
3/4” NPT
M25
3
GK 1”
G 1”
1” NPT
M32
4
GK 1-1/4”
G 1-1/4”
1-1/4” NPT
M40
5
GK 1-1/2”
G 1-1/2”
1-1/2” NPT
M50
6
GK 2”
G 2”
2” NPT
M63
7
GK 2-1/2”
G 2-1/2”
2-1/2” NPT
M75
8
GK 3”
G 3”
3” NPT
M85
REMARK:
Due to the development of the national and international specifications and of the technology, the above technical characteristics showed
on this bulletin can be considered as binding on our confirmation only.
Since 1961
4 - Feam Catalogue 03
YOUR PARTNER FOR SAFETY