This document provides information on explosion proof cable glands for armored cables. It describes the mechanical characteristics, materials, finishes, seals, and dimensions of the non-barrier and barrier cable gland models. Various models are listed with details on thread size, material options, operating temperature ranges, approvals, and ordering information to specify the correct cable gland based on application needs.
Feam EJB INX Zone 1 & Zone 2 Enclosures (Atex) Hazardous Area
Hazardous Area Enclosures:
Zone 1 & Zone 2 (Gases)
Zone 21 & Zone 22 (Dusts)
Hazardous Area Classification
Group: II Category: 2G - 2D
Hazardous Area Enclosure Approvals
ATEX
II 2 G Ex db IIB+H2 T6...T3
II 2 G Ex db [ia/ib] IIB+H2 T6...T3
II 2 D Ex tb IIIC T85ºC...T150ºC
IECEx
Ex db IIB+H2 T6...T3
Ex db [ia/ib] IIB+H2 T6...T3
Ex tb IIIC T85ºC...T150ºC
INMETRO
Ex db IIB+H2 T6...T3
Ex db [ia/ib] IIB+H2 T6...T3
Ex tb IIIC T85ºC...T150ºC
GOST-R GOST-K
1 Ex d IIB+H2 T6
1 Ex d [ia/ib] IIB+H2 T6
Ex tD A21 T85ºC...T150ºC
1 Ex d IIB+H2 U
NEC505
USL: Class 1, Zone 1, AEx db IIB+H2
Zone 21 AEx tb IIIC T85ºC...T150ºC
CNL: Exd IIB+H2; Class II, Groups E, F and G
FEAM EJB INX Enclosures - Mechanical Features
Stainless steel AISI-316 L body/cover
Stainless steel AISI-316 L screws
Stainless steel AISI-316 L/aluminium internal mounting plate
Stainless steel AISI-316 L fixing lugs - stainless steel stirrups sp.10mm (EJB71/73 and EJB91/93)
Hinges welded on cover and body
Opening handle - insulating material fixed on cover by stainless steel screws
FEAM enclosures are suitable for Hazardous Area Enclosures Zone 1 & Zone 2. T&D are distributors for the FEAM range of Hazardous Area Enclosures for installation in potentially explosive atmospheres - FEAM enclosures are specified for hazardous areas Zone 1 and Zone 2 (Gases) with international certifications according to ATEX, Inmetro, GOST-R, GOST-K, IECEx and CE.
ATEX, IECEx, Inmetro, GOST-R, GOST-K, NEC505 Certified Enclosures.
Hazardous Area Enclosures : Zone 1 & Zone 2 (Gases) - Zone 21 & Zone 22 (Dusts).
Hazardous Area Classification
Group: II Category: 2G - 2D
This document provides specifications for explosion proof lighting fixtures for use in hazardous areas. The fixtures, called EVAC, are approved for Zone 1, 2, 21, 22 installations and have an IP66 protection degree. They have an aluminum body and glass globe, are painted gray, and have stainless steel screws. Electrical characteristics include power supply of 220-240V, 50/60Hz and cable entry of 3/4" NPT. Various mounting options and accessories are also listed.
The document provides technical specifications for multiple explosion proof electrical equipment products, including:
1) Control stations that can accommodate various operator configurations and accessories. They are rated for hazardous gas and dust areas and certified to international compliance standards.
2) Push buttons and control stations with mechanical and electrical ratings. Models include various execution options certified for gas and dust hazardous areas.
3) Dimensional and technical data for product lines that include circuit breakers, switches, and push buttons. Specifications include enclosure ratings and temperature classifications.
ROTEX Controls Industrial NEMA 4 and NEMA 7 Limit Switch CatalogROTEX Controls USA
The document provides information on various limit switch and mounting bracket options from Versatile Limitswitch Controls, Inc. It includes technical specifications for weatherproof and explosion proof limit switches with mechanical switches or proximity sensors. Mounting brackets for the switches are also detailed along with materials, dimensions, and ordering codes.
This document provides information on solenoid valves from Asconumatics including:
- Power levels range from 0.5W to 11.2W for basic, medium, reduced, and low power valves.
- Valves are certified to safety standards like IEC 61508 and have explosion proof, flame proof, and other options.
- Technical specifications include flow rates, pressure ranges, materials, temperature ranges, electrical characteristics and more.
- Selection information includes identifying the basic catalogue number, prefixes for additional options, suffixes, voltage, and ordering format.
Abtech ZAG Aluminium Enclosures & Junction Boxes for Hazardous Areas
Abtech Aluminium Electrical Enclosures & Junction Boxes (Zone 1 & 2, ATEX) - Abtech ZAG
The Abtech ZAG range of aluminium enclosures and junction boxes includes 19 sizes that are precision die cast in Al Si 12 grade (LM24) aluminum alloy - the most suitable grade of aluminum for maximum corrosion resistance of junction boxes, especially in salt and corrosive atmospheres.
The Abtech ZAG range of aluminium enclosures and junction boxes have many features for use in a wide range of electrical applications - including industrial and hazardous area junction boxes and OEM applications where the excellent machining qualities of aluminium are preferred.
The Abtech ZAG range of aluminium enclosures and junction boxes can be machined, drilled, tapped with various thread forms and readily accepts most paint finishes and colours.
Abtech ZAG Aluminium Enclosures & Junction Boxes
Abtech ZAG Aluminium Enclosures & Junction Boxes, Features :
Wide operating temperature (-70 to +130 degrees Celsius)
Ingress protection to IP67, Corrosion resistant
Zone 1 & 2 hazardous area certified - UL, CSA, ATEX, GOST approved
Hazardous Area Certified Aluminium Enclosures & Junction Boxes
Abtech ZAG enclosures and junction boxes carry global hazardous area certifications - ATEX EEx'e' to BSEN50019 (Zone 1 & 2), EEX'nA' to BSEN50021 (Zone 2), NEMA 4X (CSA, UL & FM Class 1 Div 2).
Feam EJB INX Zone 1 & Zone 2 Enclosures (Atex) Hazardous Area
Hazardous Area Enclosures:
Zone 1 & Zone 2 (Gases)
Zone 21 & Zone 22 (Dusts)
Hazardous Area Classification
Group: II Category: 2G - 2D
Hazardous Area Enclosure Approvals
ATEX
II 2 G Ex db IIB+H2 T6...T3
II 2 G Ex db [ia/ib] IIB+H2 T6...T3
II 2 D Ex tb IIIC T85ºC...T150ºC
IECEx
Ex db IIB+H2 T6...T3
Ex db [ia/ib] IIB+H2 T6...T3
Ex tb IIIC T85ºC...T150ºC
INMETRO
Ex db IIB+H2 T6...T3
Ex db [ia/ib] IIB+H2 T6...T3
Ex tb IIIC T85ºC...T150ºC
GOST-R GOST-K
1 Ex d IIB+H2 T6
1 Ex d [ia/ib] IIB+H2 T6
Ex tD A21 T85ºC...T150ºC
1 Ex d IIB+H2 U
NEC505
USL: Class 1, Zone 1, AEx db IIB+H2
Zone 21 AEx tb IIIC T85ºC...T150ºC
CNL: Exd IIB+H2; Class II, Groups E, F and G
FEAM EJB INX Enclosures - Mechanical Features
Stainless steel AISI-316 L body/cover
Stainless steel AISI-316 L screws
Stainless steel AISI-316 L/aluminium internal mounting plate
Stainless steel AISI-316 L fixing lugs - stainless steel stirrups sp.10mm (EJB71/73 and EJB91/93)
Hinges welded on cover and body
Opening handle - insulating material fixed on cover by stainless steel screws
FEAM enclosures are suitable for Hazardous Area Enclosures Zone 1 & Zone 2. T&D are distributors for the FEAM range of Hazardous Area Enclosures for installation in potentially explosive atmospheres - FEAM enclosures are specified for hazardous areas Zone 1 and Zone 2 (Gases) with international certifications according to ATEX, Inmetro, GOST-R, GOST-K, IECEx and CE.
ATEX, IECEx, Inmetro, GOST-R, GOST-K, NEC505 Certified Enclosures.
Hazardous Area Enclosures : Zone 1 & Zone 2 (Gases) - Zone 21 & Zone 22 (Dusts).
Hazardous Area Classification
Group: II Category: 2G - 2D
This document provides specifications for explosion proof lighting fixtures for use in hazardous areas. The fixtures, called EVAC, are approved for Zone 1, 2, 21, 22 installations and have an IP66 protection degree. They have an aluminum body and glass globe, are painted gray, and have stainless steel screws. Electrical characteristics include power supply of 220-240V, 50/60Hz and cable entry of 3/4" NPT. Various mounting options and accessories are also listed.
The document provides technical specifications for multiple explosion proof electrical equipment products, including:
1) Control stations that can accommodate various operator configurations and accessories. They are rated for hazardous gas and dust areas and certified to international compliance standards.
2) Push buttons and control stations with mechanical and electrical ratings. Models include various execution options certified for gas and dust hazardous areas.
3) Dimensional and technical data for product lines that include circuit breakers, switches, and push buttons. Specifications include enclosure ratings and temperature classifications.
ROTEX Controls Industrial NEMA 4 and NEMA 7 Limit Switch CatalogROTEX Controls USA
The document provides information on various limit switch and mounting bracket options from Versatile Limitswitch Controls, Inc. It includes technical specifications for weatherproof and explosion proof limit switches with mechanical switches or proximity sensors. Mounting brackets for the switches are also detailed along with materials, dimensions, and ordering codes.
This document provides information on solenoid valves from Asconumatics including:
- Power levels range from 0.5W to 11.2W for basic, medium, reduced, and low power valves.
- Valves are certified to safety standards like IEC 61508 and have explosion proof, flame proof, and other options.
- Technical specifications include flow rates, pressure ranges, materials, temperature ranges, electrical characteristics and more.
- Selection information includes identifying the basic catalogue number, prefixes for additional options, suffixes, voltage, and ordering format.
Abtech ZAG Aluminium Enclosures & Junction Boxes for Hazardous Areas
Abtech Aluminium Electrical Enclosures & Junction Boxes (Zone 1 & 2, ATEX) - Abtech ZAG
The Abtech ZAG range of aluminium enclosures and junction boxes includes 19 sizes that are precision die cast in Al Si 12 grade (LM24) aluminum alloy - the most suitable grade of aluminum for maximum corrosion resistance of junction boxes, especially in salt and corrosive atmospheres.
The Abtech ZAG range of aluminium enclosures and junction boxes have many features for use in a wide range of electrical applications - including industrial and hazardous area junction boxes and OEM applications where the excellent machining qualities of aluminium are preferred.
The Abtech ZAG range of aluminium enclosures and junction boxes can be machined, drilled, tapped with various thread forms and readily accepts most paint finishes and colours.
Abtech ZAG Aluminium Enclosures & Junction Boxes
Abtech ZAG Aluminium Enclosures & Junction Boxes, Features :
Wide operating temperature (-70 to +130 degrees Celsius)
Ingress protection to IP67, Corrosion resistant
Zone 1 & 2 hazardous area certified - UL, CSA, ATEX, GOST approved
Hazardous Area Certified Aluminium Enclosures & Junction Boxes
Abtech ZAG enclosures and junction boxes carry global hazardous area certifications - ATEX EEx'e' to BSEN50019 (Zone 1 & 2), EEX'nA' to BSEN50021 (Zone 2), NEMA 4X (CSA, UL & FM Class 1 Div 2).
The document provides information on explosion proof electrical equipment from Feam including earthing clamps, electronic grounding systems, and acoustic signallers.
The earthing clamps (IT25 series) are used to connect tankers to ground during loading and unloading operations. The electronic grounding systems (SM2021 series) are used to verify grounding connections and allow loading/unloading when resistance is less than 20 ohms. The acoustic signallers (ETH2 and S2 series) provide audible alarms in hazardous areas.
This document provides information on multiple control stations and push buttons for use in hazardous areas. It includes:
- Technical specifications for multiple control stations that are classified for gas and dust hazardous areas and certified to European and Russian standards.
- Diagrams showing the configurations and maximum number of operators that can be installed on the control stations.
- Technical data sheets listing the dimensions, material specifications, temperature ratings and other details for the control stations and push buttons.
- Notes that the technical characteristics are subject to change and require confirmation.
So in summary, the document outlines explosion proof electrical equipment for hazardous areas, including multiple control stations and push buttons, and provides the relevant technical specifications and compliance information.
This document provides information on switchracks and explosion proof electrical enclosures manufactured by FEAM, including:
- Details on switchrack and enclosure models like dimensions, materials, and certifications.
- Descriptions of ordering and customization options, quality control processes, and responsibilities during production.
- Explanations of the uses of switchracks for assembling control units and enclosure usage in hazardous areas.
The document provides information on CMP's Type A2F Tri-Star cable gland, which is certified for use in hazardous areas. It is a triple certified flameproof, increased safety, and restricted breathing cable gland suitable for zones 1, 2, 21, and 22. The summary includes technical details such as certifications, approvals, material specifications, sizing information, and ordering references.
The document provides technical specifications for the E1FX Tri-Star Flameproof, Increased Safety and Restricted Breathing cable gland, including its certifications, materials, sizing options, and compliance with various international standards for use in hazardous areas. It also includes ordering information and references to the company's other hazardous area products such as cable joints, terminations, and other accessories.
This document provides information on explosion proof lighting fixtures and emergency units. It includes technical specifications for various fluorescent tube lamp and LED lighting fixture models. Dimensions, weights, temperature ratings, certifications and compliance standards are listed. Graphs show light output and beam angle distributions. Instructions are also provided for different mounting options like wall, pole, ceiling or pendant mounting.
The document describes the SX range of enclosures which are available in either stainless steel or mild steel in various sizes. The enclosures can be fitted with removable gland plates and come with different paint and surface finish options. Cable entries can be drilled in the door, sides, or gland plates. Earthing is accomplished through an internal/external earth stud. The enclosures are suitable for hazardous and industrial applications and provide ingress protection up to IP68.
Peppers has an extensive range of international approvals incorporating ATEX, IECEx, UL, CSA, GOST, INMETRO &
NEPSI as well as marine type approvals by ABS (American Bureau of Shipping), RMRS (Russian Maritime) & Lloyd’s Register. Our range of approved products are designed and tested for use in Ex d, Ex e, Ex nR and Ex t hazardous area protection concepts.
Peppers’ range of glands incorporate some unique engineering features. The CR gland for armoured cable features a single orientation clamping system, “CROCLOCK®” allowing the clamping of all armour types with no mistakes being possible during installation. The advertising slogan “No reversible Components – No Mistakes” sums up this benefit. Due to ingenious design features Deluge is achieved without the use of additional sealing devices.
Peppers’ barrier glands incorporate unique features that reduce installation times by using the Peppers T-1000 compound, which enables the conductors to be terminated within the equipment after one hour. At four hours, the compound chamber may be inspected and the equipment can be energized. Our innovative barrier chamber provides a cable acceptance that is on average 17% larger than other barrier gland designs allowing the use of smaller glands thereby significantly reducing cost.
Glands can be supplied in various materials including brass, aluminium, stainless steel and polyamide. We offer plating options for corrosion protection, including nickel, tin and zinc. Peppers also supply accessories, which include a comprehensive range of certified thread adaptors, reducers, stopping plugs and breather drains.
This document provides information on switch disconnectors, fuse combination switches, and changeover switches from Craig & Derricott. It includes details on their i-switch range which combines modern styling with cost-effective design. The i-switch range includes IP41 and IP65 sealed enclosures in moulded plastic, deep drawn steel, and stainless steel. It provides electrical and mechanical specifications for isolator interiors rated from 20A to 80A.
These junction boxes are designed for making electrical connections in hazardous areas. They provide increased safety and intrinsic safety, allowing them to be used in zones 1 & 2 (gas), 21 & 22 (dust). They are also suitable for wet environments thanks to their corrosion resistance and IP66 rating. The boxes come in various sizes to accommodate different conductor cross-sections and terminal connections up to 350A.
This document provides information on ATEX Zone 22 certified switch-disconnectors and isolators from Craig & Derricott for use in explosive dust atmospheres. It lists product ratings from 20A to 63A, certifications that comply with relevant standards, technical specifications including short circuit ratings, and enclosure size dimensions from A to D. Applications include grain mills, powder coating plants, chemicals handling, and other industries where combustible dust may be present for short periods.
This document provides an overview of various terminal boxes, enclosures, and control equipment produced by Walsall Limited for use in hazardous areas. It describes features and specifications of their flameproof, increased safety, and intrinsically safe product lines for terminal boxes, local control stations, control panels, junction boxes, and other electrical equipment. The document establishes Walsall as a global supplier of explosion proof electrical equipment with a wide range of certified product options for integration into system solutions in hazardous environments.
This document provides information on Feam switchracks and explosion proof electrical enclosures. It describes the construction and materials used in Feam enclosures, which are made of marine grade aluminum or stainless steel. They are tested and certified for use in hazardous areas. The document outlines ordering information needed such as area classification, applicable standards, and electrical diagrams. It also describes Feam's quality control and testing procedures.
This document provides information on explosion proof lighting fixtures and emergency lighting units made by EVF, including:
- Technical specifications and performance details for various fluorescent lighting fixture models.
- Installation and mounting options like ceiling, pole, and pendant mounting.
- Accessories available including protective guards, reflectors, and mounting hardware.
- Compliance with European and Russian certification standards for use in hazardous areas.
This document provides information on cable glands for hazardous locations including:
- The cable glands are certified for flameproof, increased safety, and dust protection applications in various zones and divisions.
- They provide sealing and clamping for armored cables with operating temperatures from -60°C to +80°C.
- The document includes specifications, certifications, ordering information, and selection tables for different cable gland sizes to accommodate a wide range of cable dimensions.
This document provides information on the E2FW Tri-Star Flameproof Ex d, Increased Safety Ex e and Restricted Breathing Ex nR Cable Gland from CMP Products, including:
- It is certified for use in hazardous areas with lead covered or lead sheathed cables in Zone 1, Zone 2, Zone 21 and Zone 22.
- It provides flameproof and gas tight seals and allows for mechanical cable retention, earth continuity and testing of seal effectiveness.
- Technical data and specifications are provided including operating temperature range, ingress protection rating, material options and available sizes.
This document provides information on the E2FW Tri-Star Flameproof Ex d, Increased Safety Ex e and Restricted Breathing Ex nR Cable Gland from CMP Products, including:
- It is certified for use in hazardous areas with lead covered or lead sheathed cables in Zone 1, Zone 2, Zone 21 and Zone 22.
- It provides flameproof and gas tight seals and allows for mechanical cable retention, earth continuity and testing of seal effectiveness.
- Technical data and specifications are provided including operating temperature range, ingress protection rating, material options and available sizes.
CMP PX2K Cable Glands (Barrier Glands Exd Flameproof with ATEX Certification for Hazardous Areas)
Cable Gland Size 20S (M20) 1/2" NPT Entry Thread Standard, 3/4" NPT Optional
Cable Gland Suits Cable Diameters 9.5mm-15.9mm
CMP PX2K barrier cable glands are ATEX certified and suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2, Zone 21 and Zone 22. Flameproof compound filled barrier glands for cable terminations within ATEX areas are supplied with a "universal" reversible armour ring to suit all types of armoured cables - this includes steel wire armoured (SWA), steel tape armoured (STA) and wire braided cables for installation within hazardous areas. Barrier cable glands provide a compound barrier seal around the cable conductors and an environmental seal on the cable outer sheath. The CMP PX2K cable gland provides a mechanical cable retention and electrical continuity via the cable armour termination. A combined detachable armour cone and compound tube, together with AnyWay universal cable clamping ring arrangement allows the cable to be easily disconnected from the electrical equipment and easily re-connected. This cable gland feature facilitates remote make off procedures when the cable termination is to be conducted in confined spaces or in areas of restricted access.
Cable Glands are suitable for following cable types - Wire Braid Armour, Single Steel Wire Armour (SWA), Screened Flexible Wire Braid (eg CY or SY), Steel Tape Armour (STA), Pliable Wire Armour (PWA)
Cable Sealing Area - Inner Compound Barrier and Cable Outer Sheath
CMP PX2K cable glands with offshore and marine approvals including Lloyds, DNV and ABS are available - LSF cable gland shrouds available for low smoke and fume cable terminations.
CMP PX2K Barrier Cable Glands (ATEX Certified) for Hazardous Areas
Zone 1, Zone 2, Zone 21, Zone 22 (Flameproof Exd) Cable Termination
CMP PX2K Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) barrier gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas - suitable with all types of armoured cable providing a compound barrier seal around the cable conductors and an environmental seal on the cable outer sheath.
CMP PX2K barrier cable glands are ATEX certified for use with equipment protection permitted in Zone 1, Zone 2, Zone 21 and Zone 22. Flameproof compound barrier glands for cable terminations within ATEX hazardous areas areas are supplied with a "universal" reversible armour clamp to suit all types of armoured cable termination - this includes steel wire armoured (SWA), steel tape armoured (STA) and wire braided cables for installation within hazardous areas.
CMP PXSS2K barrier cable glands are Class I Division 2 ABCD approved for use with non-armoured marine and tray cable (type TC) providing a compound barrier seal around the cable conductors and an environmental seal on the cable outer jacket - the PXSS2K barrier glands are IP68 rated.
CMP PX2K and PXSS2K barrier cable glands provide mechanical cable retention - a combined detachable spacer and compound tube allows the cable to be easily disconnected from the equipment for maintenance. This feature also facilitates remote make off procedures when the barrier termination is to be conducted in confined spaces.
CMP PX2K Cable Glands (Barrier Glands Exd Flameproof with ATEX Certification for Hazardous Areas)
Cable Gland Size 40 (M40) 1.1/4" NPT Entry Thread Standard, 1.1/2" NPT Optional
Cable Gland Suits Cable Diameters 27.9mm-40.4mm
CMP PX2K barrier cable glands are ATEX certified and suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2, Zone 21 and Zone 22. Flameproof compound filled barrier glands for cable terminations within ATEX areas are supplied with a "universal" reversible armour ring to suit all types of armoured cables - this includes steel wire armoured (SWA), steel tape armoured (STA) and wire braided cables for installation within hazardous areas. Barrier cable glands provide a compound barrier seal around the cable conductors and an environmental seal on the cable outer sheath. The CMP PX2K cable gland provides a mechanical cable retention and electrical continuity via the cable armour termination. A combined detachable armour cone and compound tube, together with AnyWay universal cable clamping ring arrangement allows the cable to be easily disconnected from the electrical equipment and easily re-connected. This cable gland feature facilitates remote make off procedures when the cable termination is to be conducted in confined spaces or in areas of restricted access.
Cable Glands are suitable for following cable types - Wire Braid Armour, Single Steel Wire Armour (SWA), Screened Flexible Wire Braid (eg CY or SY), Steel Tape Armour (STA), Pliable Wire Armour (PWA)
Cable Sealing Area - Inner Compound Barrier and Cable Outer Sheath
CMP PX2K cable glands with offshore and marine approvals including Lloyds, DNV and ABS are available - LSF cable gland shrouds available for low smoke and fume cable terminations.
This document provides information on the VDY series of incandescent lighting fixtures from NAMBUK Electric Co. It includes three sections:
1. An overview of the VDY series, which are weatherproof fixtures intended for industrial applications where weather damage is a concern.
2. Technical specifications for the VDY fixtures, including materials, finishes, certifications, and photometric data.
3. Dimensional drawings and ordering information.
The Rittal Flex-Block base/plinth system provides a freely combinable and toolless base/plinth solution for enclosures. The corner pieces support the enclosure load and allow trim panels to be easily attached or removed with clips. Trim panels are symmetrical and interchangeable in width and depth, providing flexibility. Ordering corner pieces and trim panels separately allows customizing to any application and potential cost savings versus complete base/plinth units. Accessories like punched rails, baying clips, and mounting plates provide cable management and installation options.
The document provides information on explosion proof electrical equipment from Feam including earthing clamps, electronic grounding systems, and acoustic signallers.
The earthing clamps (IT25 series) are used to connect tankers to ground during loading and unloading operations. The electronic grounding systems (SM2021 series) are used to verify grounding connections and allow loading/unloading when resistance is less than 20 ohms. The acoustic signallers (ETH2 and S2 series) provide audible alarms in hazardous areas.
This document provides information on multiple control stations and push buttons for use in hazardous areas. It includes:
- Technical specifications for multiple control stations that are classified for gas and dust hazardous areas and certified to European and Russian standards.
- Diagrams showing the configurations and maximum number of operators that can be installed on the control stations.
- Technical data sheets listing the dimensions, material specifications, temperature ratings and other details for the control stations and push buttons.
- Notes that the technical characteristics are subject to change and require confirmation.
So in summary, the document outlines explosion proof electrical equipment for hazardous areas, including multiple control stations and push buttons, and provides the relevant technical specifications and compliance information.
This document provides information on switchracks and explosion proof electrical enclosures manufactured by FEAM, including:
- Details on switchrack and enclosure models like dimensions, materials, and certifications.
- Descriptions of ordering and customization options, quality control processes, and responsibilities during production.
- Explanations of the uses of switchracks for assembling control units and enclosure usage in hazardous areas.
The document provides information on CMP's Type A2F Tri-Star cable gland, which is certified for use in hazardous areas. It is a triple certified flameproof, increased safety, and restricted breathing cable gland suitable for zones 1, 2, 21, and 22. The summary includes technical details such as certifications, approvals, material specifications, sizing information, and ordering references.
The document provides technical specifications for the E1FX Tri-Star Flameproof, Increased Safety and Restricted Breathing cable gland, including its certifications, materials, sizing options, and compliance with various international standards for use in hazardous areas. It also includes ordering information and references to the company's other hazardous area products such as cable joints, terminations, and other accessories.
This document provides information on explosion proof lighting fixtures and emergency units. It includes technical specifications for various fluorescent tube lamp and LED lighting fixture models. Dimensions, weights, temperature ratings, certifications and compliance standards are listed. Graphs show light output and beam angle distributions. Instructions are also provided for different mounting options like wall, pole, ceiling or pendant mounting.
The document describes the SX range of enclosures which are available in either stainless steel or mild steel in various sizes. The enclosures can be fitted with removable gland plates and come with different paint and surface finish options. Cable entries can be drilled in the door, sides, or gland plates. Earthing is accomplished through an internal/external earth stud. The enclosures are suitable for hazardous and industrial applications and provide ingress protection up to IP68.
Peppers has an extensive range of international approvals incorporating ATEX, IECEx, UL, CSA, GOST, INMETRO &
NEPSI as well as marine type approvals by ABS (American Bureau of Shipping), RMRS (Russian Maritime) & Lloyd’s Register. Our range of approved products are designed and tested for use in Ex d, Ex e, Ex nR and Ex t hazardous area protection concepts.
Peppers’ range of glands incorporate some unique engineering features. The CR gland for armoured cable features a single orientation clamping system, “CROCLOCK®” allowing the clamping of all armour types with no mistakes being possible during installation. The advertising slogan “No reversible Components – No Mistakes” sums up this benefit. Due to ingenious design features Deluge is achieved without the use of additional sealing devices.
Peppers’ barrier glands incorporate unique features that reduce installation times by using the Peppers T-1000 compound, which enables the conductors to be terminated within the equipment after one hour. At four hours, the compound chamber may be inspected and the equipment can be energized. Our innovative barrier chamber provides a cable acceptance that is on average 17% larger than other barrier gland designs allowing the use of smaller glands thereby significantly reducing cost.
Glands can be supplied in various materials including brass, aluminium, stainless steel and polyamide. We offer plating options for corrosion protection, including nickel, tin and zinc. Peppers also supply accessories, which include a comprehensive range of certified thread adaptors, reducers, stopping plugs and breather drains.
This document provides information on switch disconnectors, fuse combination switches, and changeover switches from Craig & Derricott. It includes details on their i-switch range which combines modern styling with cost-effective design. The i-switch range includes IP41 and IP65 sealed enclosures in moulded plastic, deep drawn steel, and stainless steel. It provides electrical and mechanical specifications for isolator interiors rated from 20A to 80A.
These junction boxes are designed for making electrical connections in hazardous areas. They provide increased safety and intrinsic safety, allowing them to be used in zones 1 & 2 (gas), 21 & 22 (dust). They are also suitable for wet environments thanks to their corrosion resistance and IP66 rating. The boxes come in various sizes to accommodate different conductor cross-sections and terminal connections up to 350A.
This document provides information on ATEX Zone 22 certified switch-disconnectors and isolators from Craig & Derricott for use in explosive dust atmospheres. It lists product ratings from 20A to 63A, certifications that comply with relevant standards, technical specifications including short circuit ratings, and enclosure size dimensions from A to D. Applications include grain mills, powder coating plants, chemicals handling, and other industries where combustible dust may be present for short periods.
This document provides an overview of various terminal boxes, enclosures, and control equipment produced by Walsall Limited for use in hazardous areas. It describes features and specifications of their flameproof, increased safety, and intrinsically safe product lines for terminal boxes, local control stations, control panels, junction boxes, and other electrical equipment. The document establishes Walsall as a global supplier of explosion proof electrical equipment with a wide range of certified product options for integration into system solutions in hazardous environments.
This document provides information on Feam switchracks and explosion proof electrical enclosures. It describes the construction and materials used in Feam enclosures, which are made of marine grade aluminum or stainless steel. They are tested and certified for use in hazardous areas. The document outlines ordering information needed such as area classification, applicable standards, and electrical diagrams. It also describes Feam's quality control and testing procedures.
This document provides information on explosion proof lighting fixtures and emergency lighting units made by EVF, including:
- Technical specifications and performance details for various fluorescent lighting fixture models.
- Installation and mounting options like ceiling, pole, and pendant mounting.
- Accessories available including protective guards, reflectors, and mounting hardware.
- Compliance with European and Russian certification standards for use in hazardous areas.
This document provides information on cable glands for hazardous locations including:
- The cable glands are certified for flameproof, increased safety, and dust protection applications in various zones and divisions.
- They provide sealing and clamping for armored cables with operating temperatures from -60°C to +80°C.
- The document includes specifications, certifications, ordering information, and selection tables for different cable gland sizes to accommodate a wide range of cable dimensions.
This document provides information on the E2FW Tri-Star Flameproof Ex d, Increased Safety Ex e and Restricted Breathing Ex nR Cable Gland from CMP Products, including:
- It is certified for use in hazardous areas with lead covered or lead sheathed cables in Zone 1, Zone 2, Zone 21 and Zone 22.
- It provides flameproof and gas tight seals and allows for mechanical cable retention, earth continuity and testing of seal effectiveness.
- Technical data and specifications are provided including operating temperature range, ingress protection rating, material options and available sizes.
This document provides information on the E2FW Tri-Star Flameproof Ex d, Increased Safety Ex e and Restricted Breathing Ex nR Cable Gland from CMP Products, including:
- It is certified for use in hazardous areas with lead covered or lead sheathed cables in Zone 1, Zone 2, Zone 21 and Zone 22.
- It provides flameproof and gas tight seals and allows for mechanical cable retention, earth continuity and testing of seal effectiveness.
- Technical data and specifications are provided including operating temperature range, ingress protection rating, material options and available sizes.
CMP PX2K Cable Glands (Barrier Glands Exd Flameproof with ATEX Certification for Hazardous Areas)
Cable Gland Size 20S (M20) 1/2" NPT Entry Thread Standard, 3/4" NPT Optional
Cable Gland Suits Cable Diameters 9.5mm-15.9mm
CMP PX2K barrier cable glands are ATEX certified and suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2, Zone 21 and Zone 22. Flameproof compound filled barrier glands for cable terminations within ATEX areas are supplied with a "universal" reversible armour ring to suit all types of armoured cables - this includes steel wire armoured (SWA), steel tape armoured (STA) and wire braided cables for installation within hazardous areas. Barrier cable glands provide a compound barrier seal around the cable conductors and an environmental seal on the cable outer sheath. The CMP PX2K cable gland provides a mechanical cable retention and electrical continuity via the cable armour termination. A combined detachable armour cone and compound tube, together with AnyWay universal cable clamping ring arrangement allows the cable to be easily disconnected from the electrical equipment and easily re-connected. This cable gland feature facilitates remote make off procedures when the cable termination is to be conducted in confined spaces or in areas of restricted access.
Cable Glands are suitable for following cable types - Wire Braid Armour, Single Steel Wire Armour (SWA), Screened Flexible Wire Braid (eg CY or SY), Steel Tape Armour (STA), Pliable Wire Armour (PWA)
Cable Sealing Area - Inner Compound Barrier and Cable Outer Sheath
CMP PX2K cable glands with offshore and marine approvals including Lloyds, DNV and ABS are available - LSF cable gland shrouds available for low smoke and fume cable terminations.
CMP PX2K Barrier Cable Glands (ATEX Certified) for Hazardous Areas
Zone 1, Zone 2, Zone 21, Zone 22 (Flameproof Exd) Cable Termination
CMP PX2K Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) barrier gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas - suitable with all types of armoured cable providing a compound barrier seal around the cable conductors and an environmental seal on the cable outer sheath.
CMP PX2K barrier cable glands are ATEX certified for use with equipment protection permitted in Zone 1, Zone 2, Zone 21 and Zone 22. Flameproof compound barrier glands for cable terminations within ATEX hazardous areas areas are supplied with a "universal" reversible armour clamp to suit all types of armoured cable termination - this includes steel wire armoured (SWA), steel tape armoured (STA) and wire braided cables for installation within hazardous areas.
CMP PXSS2K barrier cable glands are Class I Division 2 ABCD approved for use with non-armoured marine and tray cable (type TC) providing a compound barrier seal around the cable conductors and an environmental seal on the cable outer jacket - the PXSS2K barrier glands are IP68 rated.
CMP PX2K and PXSS2K barrier cable glands provide mechanical cable retention - a combined detachable spacer and compound tube allows the cable to be easily disconnected from the equipment for maintenance. This feature also facilitates remote make off procedures when the barrier termination is to be conducted in confined spaces.
CMP PX2K Cable Glands (Barrier Glands Exd Flameproof with ATEX Certification for Hazardous Areas)
Cable Gland Size 40 (M40) 1.1/4" NPT Entry Thread Standard, 1.1/2" NPT Optional
Cable Gland Suits Cable Diameters 27.9mm-40.4mm
CMP PX2K barrier cable glands are ATEX certified and suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2, Zone 21 and Zone 22. Flameproof compound filled barrier glands for cable terminations within ATEX areas are supplied with a "universal" reversible armour ring to suit all types of armoured cables - this includes steel wire armoured (SWA), steel tape armoured (STA) and wire braided cables for installation within hazardous areas. Barrier cable glands provide a compound barrier seal around the cable conductors and an environmental seal on the cable outer sheath. The CMP PX2K cable gland provides a mechanical cable retention and electrical continuity via the cable armour termination. A combined detachable armour cone and compound tube, together with AnyWay universal cable clamping ring arrangement allows the cable to be easily disconnected from the electrical equipment and easily re-connected. This cable gland feature facilitates remote make off procedures when the cable termination is to be conducted in confined spaces or in areas of restricted access.
Cable Glands are suitable for following cable types - Wire Braid Armour, Single Steel Wire Armour (SWA), Screened Flexible Wire Braid (eg CY or SY), Steel Tape Armour (STA), Pliable Wire Armour (PWA)
Cable Sealing Area - Inner Compound Barrier and Cable Outer Sheath
CMP PX2K cable glands with offshore and marine approvals including Lloyds, DNV and ABS are available - LSF cable gland shrouds available for low smoke and fume cable terminations.
This document provides information on the VDY series of incandescent lighting fixtures from NAMBUK Electric Co. It includes three sections:
1. An overview of the VDY series, which are weatherproof fixtures intended for industrial applications where weather damage is a concern.
2. Technical specifications for the VDY fixtures, including materials, finishes, certifications, and photometric data.
3. Dimensional drawings and ordering information.
The Rittal Flex-Block base/plinth system provides a freely combinable and toolless base/plinth solution for enclosures. The corner pieces support the enclosure load and allow trim panels to be easily attached or removed with clips. Trim panels are symmetrical and interchangeable in width and depth, providing flexibility. Ordering corner pieces and trim panels separately allows customizing to any application and potential cost savings versus complete base/plinth units. Accessories like punched rails, baying clips, and mounting plates provide cable management and installation options.
The document summarizes the CM Compact Medium enclosure system from Rittal. It has 1-door and 2-door sizes from 600mm to 1200mm widths. It provides more flexibility than the AK enclosures it replaces through interior installation with TS8 accessories, more cable entry space and options, and easier mounting plate installation. It is compatible with TS8 components and accessories to allow infinite configuration possibilities.
The document provides an overview of Rittal's PS 4000s enclosure system, including:
- The PS profile offers maximum stability using a 9-fold profile design with a 24-row 25mm grid hole pattern for universal assembly without manual machining.
- The enclosures are tested to international standards to guarantee high quality and come in various sizes, configurations, and options.
- Product details are provided like materials, finishes, included components, and protection ratings for the different PS 4000s enclosure models.
- Specification tables list the technical details and product codes for the enclosures.
The document discusses the benefits of exercise for mental health. Regular physical activity can help reduce anxiety and depression and improve mood and cognitive functioning. Exercise causes chemical changes in the brain that may help protect against mental illness and improve symptoms.
The document is the Rittal catalogue for 2014/2015 and includes details on Rittal's range of enclosure products including small enclosures, compact enclosures, enclosure systems, IT enclosure systems, console systems, operating housings, and accessories. It provides information on Rittal's polycarbonate enclosures, cast aluminium enclosures, terminal boxes, and bus enclosures. The enclosures range in size from the smallest polycarbonate enclosures to large enclosure systems.
1. YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
PAPD
Anelli premiarmatura ottone nichelato
PAPD
Feam Catalogue 01 - 131
Ex Cable Glands
CABLE GLANDS FOR
ARMOURED CABLES
On Request Accessories:
• Locknuts, Gaskets, PVC Shrouds, Earthing Tags, Sealing (See ACCESSORI bulletin)
Mechanical characteristics
Body / cap OT-58 marine brass (ON) - AISI-316L stainless steel (IX) - *anticorodal aluminium (AL)
Finishes full nickel plating threatment (brass material only)
Rubber rings EDPM rubber- 50-60 shore hardness
O-ring silicon rubber - 60 shore hardness
Skid washer nylon 6
Chamber for sealing OT-58 marine brass ("R" version only)
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
APPLICATION
• FOR STEEL WIRE ARMOURED CABLES (SWA) FOR STEEL TAPE ARMOURED CABLES AND FOR LEAD INNER SHEATH CABLES
• DOUBLE COMPRESSION TYPE FOR INDOOR AND OUTDOOR USE
• PROVIDED ARMOUR CLAMPING USING CLAMPING ARRANGEMENTS SUITABLE FOR ALL ARMOUR WIRE/BRAID TYPES
• INTERNAL LEAD DEVICE FOR ELECTRICAL BOND OF CABLE LEAD INNER SHEATH
• DOUBLE COMPRESSION - UNDER ARMOUR AND OVERALL OF ARMOUR CABLE ( INNER AND OUTER SEALING )
• SEALING WITH PROPER RESIN INTO "CHAMBER OF SEALING" ( ON BARRIER TYPE VERSION "R" ONLY )
*ON REQUEST ONLY. PLEASE CONTACT OUR SALES OFFICE FOR MIN QUANTITY TO ORDER
CABLE GLANDS
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex d II C
II 2 G Ex e II
II 2 D Ex tD A21
Ex d IIC / Ex e II
DIP A21
Ex d IIC / Ex e II
DIP A21
AMBIENT TEMPERATURE
-40°C ÷ +90°C (1)
-50°C ÷ +180°C (2)
-40°C ÷ +90°C (1)
-60°C ÷ +180°C (2)
-40°C ÷ +90°C (1)
-60°C ÷ +180°C (2)
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 07 ATEX 0001X POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1;
EN 60079-7; EN 61241-0; EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
(1) EDPM-60 INTERNAL RUBBER RINGS - (2) SILICON-60 INTERNAL RUBBER RINGS
2. YOUR PARTNER FOR SAFETY
Since 1961
PAPD
A
C
D
B
1 2 3
5
64
7
8 9 111012
PAPD# 01 M ON
PAPD# 03 N IX
PAPD-R# 04 N AL
132 - Feam Catalogue 01
Ex Cable Glands
PAPD Cable gland selection table
CODE ENTRY THREAD SIZE (C)
INNER SHEATH
DIA. (A)
OUTER SHEATH
DIA. (B)
HEXAGON
(D)
MATERIAL
(1)
METRIC
(2)
NPT
(2)
UNI ISO 228
(2)
min
[mm]
max
[mm]
min
[mm]
max
[mm]
[mm]
(3)
PAPD#
PAPD-R#
01 ISO-M20 1/2"NPT 1/2" 4,5 11,0 10,0 19,0 32,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PAPD#
PAPD-R#
02 ISO-M25 3/4”NPT 3/4” 8,5 16,0 15,0 24,0 36,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PAPD#
PAPD-R#
03 ISO-M32 1”NPT 1” 13,0 22,0 20,0 31,0 45,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PAPD#
PAPD-R#
04 ISO-M40 1 1/4”NPT 1 1/4” 19,0 28,0 25,0 37,0 53,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PAPD#
PAPD-R#
05 ISO-M50 1 1/2”NPT 1 1/2” 22,0 34,0 31,0 43,0 61,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PAPD#
PAPD-R#
06 ISO-M63 2”NPT 2” 34,0 43,0 42,0 53,0 71,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PAPD#
PAPD-R#
07 ISO-M75 2 1/2”NPT 2 1/2” 43,0 52,0 52,0 64,0 84,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PAPD#
PAPD-R#
08 ISO-M90 3”NPT 3” 52,0 65,0 65,0 78,0 101,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
CABLE GLAND ORDERING
EXAMPLES
LEGEND
= PAPD#01MON (NON-BARRIER CABLE GLAND NICKEL PLATED BRASS ISO-M20 THR.)
= PAPD#03NIX (NON-BARRIER CABLE GLAND STAINLESS STEEL 1”NPT THR.)
= PAPD-R#04NAL (BARRIER CABLE GLAND NICKEL PLATED BRASS 1 1/4”NPT THR.)
(1) CABLE GLAND TYPE/MODEL PAPD# = NON-BARRIER CABLE GLAND - PAPD-R# = BARRIER CABLE GLAND
(2) THREADING M = ISO METRIC pitch 1,5mm - N = NPT (ANSI/ASME B1.20.1) - G = UNI ISO-228
(3) CABLE GLAND MATERIAL ON = NICKEL PLATED MARINE BRASS - IN = AISI-316L STAINLESS STEEL - AL = ANTICORODAL ALUMINIUM
REMARK: Due to the development of the national and international specifications and of the technology, the above technical
characteristics showed on this bulletin can be considered as binding on our confirmation only.
PAPD Dimensional 1. skid washer
2. outer seal
3. cable armour rings
4. cable armour rings
5. inner seal
6. *chamber for sealing
(“R” version only)
7. armoured cable
8. cap
9. middle body
10. body
11. O-ring
12. LEAD RING
SIZE
N
N
N
N
N
N
N
N
G
G
G
G
G
G
G
G
M
M
M
M
M
M
M
M
* Chamber will be filled with sealing when
cable gland is completely assembled.
3. YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
PAP
Anelli premiarmatura ottone nichelato
PAP
Feam Catalogue 01 - 133
Ex Cable Glands
CABLE GLANDS FOR
ARMOURED CABLES
On Request Accessories:
• Locknuts, Gaskets, PVC Shrouds, Earthing Tags, Sealing (See ACCESSORI bulletin)
Mechanical characteristics
Body / cap OT-58 marine brass (ON) - AISI-316L stainless steel (IX)- *anticorodal aluminium (AL)
Finishes full nickel plating threatment (brass material only)
Rubber rings EDPM rubber- 50-60 shore hardness - Silicon rubber - 60 shore hardness
O-ring silicon rubber - 60 shore hardness
Skid washer nylon 6
Chamber for sealing OT-58 marine brass ("R" version only)
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
APPLICATION
• FOR STEEL WIRE ARMOURED CABLES (SWA) FOR STEEL TAPE ARMOURED CABLES
• DOUBLE COMPRESSION TYPE FOR INDOOR AND OUTDOOR USE
• PROVIDED ARMOUR CLAMPING USING CLAMPING ARRANGEMENTS SUITABLE FOR ALL ARMOUR WIRE/BRAID TYPES
• DOUBLE COMPRESSION - UNDER ARMOUR AND OVERALL OF ARMOUR CABLE ( INNER AND OUTER SEALING )
• SEALING WITH PROPER RESIN INTO "CHAMBER OF SEALING" ( ON BARRIER TYPE VERSION "R" ONLY )
*ON REQUEST ONLY. PLEASE CONTACT OUR SALES OFFICE FOR MIN QUANTITY TO ORDER
(1) EDPM-60 INTERNAL RUBBER RINGS - (2) SILICON-60 INTERNAL RUBBER RINGS
CABLE GLANDS
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex d II C
II 2 G Ex e II
II 2 D Ex tD A21
Ex d IIC / Ex e II
DIP A21
Ex d IIC / Ex e II
DIP A21
AMBIENT TEMPERATURE
-40°C ÷ +90°C (1)
-50°C ÷ +180°C (2)
-40°C ÷ +90°C (1)
-60°C ÷ +180°C (2)
-40°C ÷ +90°C (1)
-60°C ÷ +180°C (2)
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 07 ATEX 0001X POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1;
EN 60079-7; EN 61241-0; EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
4. YOUR PARTNER FOR SAFETY
Since 1961
PAP
A
C
D
B
1 2 3 5
64
7
8 9 1110
PAP# 01 M ON
PAP# 03 N IX
PAP-R# 04 N AL
SIZE
134 - Feam Catalogue 01
CODE ENTRY THREAD SIZE (C)
INNER SHEATH
DIA. (A)
OUTER SHEATH
DIA. (B)
HEXAGON
(D)
MATERIAL
(1)
METRIC
(2)
NPT
(2)
UNI ISO 228
(2)
min
[mm]
max
[mm]
min
[mm]
max
[mm]
[mm]
(3)
PAP#
PAP-R#
00 ISO-M20 1/2”NPT 1/2” 4,0 10,0 10,0 15,0 26,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PAP#
PAP-R#
01 ISO-M20 1/2"NPT 1/2" 5,5 13,0 15,0 19,0 32,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PAP#
PAP-R#
02 ISO-M25 3/4”NPT 3/4” 10,5 18,0 15,0 24,0 36,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PAP#
PAP-R#
03 ISO-M32 1”NPT 1” 15,0 24,0 21,0 31,0 45,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PAP#
PAP-R#
04 ISO-M40 1 1/4”NPT 1 1/4” 21,0 30,0 24,0 37,0 53,0
NICKEL PL.BRASS
STAINLESS STEEL
ALLUMINIUM
ON
IX
AL
PAP#
PAP-R#
05 ISO-M50 1 1/2”NPT 1 1/2” 24,0 36,0 36,0 43,0 61,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PAP#
PAP-R#
06 ISO-M63 2”NPT 2” 36,0 45,0 45,0 53,0 71,0
NICKEL PL.BRASS
STAINLESS STEEL
ALLUMINIUM
ON
IX
AL
PAP#
PAP-R#
07 ISO-M75 2 1/2”NPT 2 1/2” 45,0 54,0 52,0 64,0 84,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PAP#
PAP-R#
08 ISO-M90 3”NPT 3” 52,0 65,0 65,0 78,0 101,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
Ex Cable Glands
PAP Cable gland selection table
CABLE GLAND ORDERING
EXAMPLES
LEGEND
(1) CABLE GLAND TYPE/MODEL PAP# = NON-BARRIER CABLE GLAND - PAP-R# = BARRIER CABLE GLAND
(2) THREADING M = ISO METRIC pitch 1,5mm - N = NPT (ANSI/ASME B1.20.1) - G = UNI ISO-228
(3) CABLE GLAND MATERIAL ON = NICKEL PLATED MARINE BRASS - IN = AISI-316L STAINLESS STEEL - AL = ANTICORODAL ALUMINIUM
REMARK: Due to the development of the national and international specifications and of the technology, the above technical
characteristics showed on this bulletin can be considered as binding on our confirmation only.
PAP Dimensional 1. skid washer
2. outer seal
3. cable armour rings
4. cable armour rings
5. inner seal
6. *chamber for sealing
(“R” version only)
7. armoured cable
8. cap
9. middle body
10. body
11. O-ring
= PAP#01MON (NON-BARRIER CABLE GLAND NICKEL PLATED BRASS ISO-M20 THR.)
= PAP#03NIX (NON-BARRIER CABLE GLAND STAINLESS STEEL 1”NPT THR.)
= PAP-R#04NAL (BARRIER CABLE GLAND NICKEL PLATED BRASS 1 1/4”NPT THR.)
M
M
M
M
M
M
M
M
M
N
N
N
N
N
N
N
N
N
G
G
G
G
G
G
G
G
G
* Chamber will be filled with sealing when
cable gland is completely assembled.
5. YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
PA
PA
Feam Catalogue 01 - 135
Ex Cable Glands
CABLE GLANDS FOR
ARMOURED CABLES
On Request Accessories:
•Locknuts, Gaskets, PVC Shrouds, Earthing Tags, Sealing (See ACCESSORI bulletin)
Mechanical characteristics
Body / cap OT-58 marine brass (ON) - AISI-316L stainless steel (IX) - *anticorodal aluminium (AL)
Finishes full nickel plating threatment (brass material only)
Rubber rings EDPM rubber- 50-60 shore hardness - Silicon rubber - 60 shore hardness
O-ring silicon rubber - 60 shore hardness
Skid washer nylon 6
Chamber for sealing OT-58 marine brass ("R" version only)
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
APPLICATION
• FOR STEEL WIRE ARMOURED CABLES (SWA) FOR STEEL TAPE ARMOURED CABLES
• DOUBLE COMPRESSION TYPE FOR INDOOR AND OUTDOOR USE
• PROVIDED ARMOUR CLAMPING USING CLAMPING ARRANGEMENTS SUITABLE FOR ALL ARMOUR WIRE/BRAID TYPES
• DOUBLE COMPRESSION - UNDER ARMOUR AND OVERALL OF ARMOUR CABLE ( INNER AND OUTER SEALING )
• SEALING WITH PROPER RESIN INTO "CHAMBER OF SEALING" ( ON BARRIER TYPE VERSION "R" ONLY )
*ON REQUEST ONLY. PLEASE CONTACT OUR SALES OFFICE FOR MIN QUANTITY TO ORDER
CABLE GLANDS
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex d II C
II 2 G Ex e II
II 2 D Ex tD A21
Ex d IIC / Ex e II
DIP A21
Ex d IIC / Ex e II
DIP A21
AMBIENT TEMPERATURE
-40°C ÷ +90°C (1)
-50°C ÷ +180°C (2)
-40°C ÷ +90°C (1)
-60°C ÷ +180°C (2)
-40°C ÷ +90°C (1)
-60°C ÷ +180°C (2)
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 07 ATEX 0001X POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1;
EN 60079-7; EN 61241-0; EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
(1) EDPM-60 INTERNAL RUBBER RINGS - (2) SILICON-60 INTERNAL RUBBER RINGS
6. YOUR PARTNER FOR SAFETY
Since 1961
PA
A
C
B
D
1 2
3
4
5 6 7
PA# 01 M ON
PA# 03 N IX
PA-R# 04 N AL
136 - Feam Catalogue 01
CODE ENTRY THREAD SIZE (C)
INNER SHEATH
DIA. (A)
OUTER SHEATH
DIA. (B)
HEXAGON
(D)
MATERIAL
(1)
METRIC
(2)
NPT
(2)
UNI ISO 228
(2)
min
[mm]
max
[mm]
max [mm] [mm]
(3)
PA#
PA-R#
00 ISO-M20 1/2"NPT 1/2" 4,0 10,0 16,0 26,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PA#
PA-R#
01 ISO-M20 1/2"NPT 1/2" 5,5 13,0 20,0 32,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PA#
PA-R#
02 ISO-M25 3/4"NPT 3/4" 10,5 18,0 25,0 36,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PA#
PA-R#
03 ISO-M32 1"NPT 1" 15,0 24,0 32,0 45,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PA#
PA-R#
04 ISO-M40 1 1/4"NPT 1 1/4" 21,0 30,0 38,0 53,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PA#
PA-R#
05 ISO-M50 1 1/2"NPT 1 1/2" 24,0 36,0 44,0 61,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PA#
PA-R#
06 ISO-M63 2"NPT 2" 36,0 45,0 54,0 71,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PA#
PA-R#
07 ISO-M75 2 1/2"NPT 2 1/2" 45,0 54,0 65,0 84,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PA#
PA-R#
08 ISO-M90 3"NPT 3" 52,0 65,0 79,0 101,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
Ex Cable Glands
PA Cable gland selection table
CABLE GLAND ORDERING
EXAMPLES
LEGEND
= PA#01MON (NON-BARRIER CABLE GLAND NICKEL PLATED BRASS ISO-M20 THR.)
= PA#03NIX (NON-BARRIER CABLE GLAND STAINLESS STEEL 1”NPT THR.)
= PA-R#04NAL (BARRIER CABLE GLAND NICKEL PLATED BRASS 1 1/4”NPT THR.)
(1) CABLE GLAND TYPE/MODEL PA# = NON-BARRIER CABLE GLAND - PA-R# = BARRIER CABLE GLAND
(2) THREADING M = ISO METRIC pitch 1,5mm - N = NPT (ANSI/ASME B1.20.1) - G = UNI ISO-228
(3) CABLE GLAND MATERIAL ON = NICKEL PLATED MARINE BRASS - IN = AISI-316L STAINLESS STEEL - AL = ANTICORODAL ALUMINIUM
REMARK: Due to the development of the national and international specifications and of the technology, the above technical
characteristics showed on this bulletin can be considered as binding on our confirmation only.
SIZE
PA Dimensional 1. cable armour rings
2. inner seal
3. * chamber for sealing
(“R” version only)
4. armoured cable
5. cap
6. body
7. O-RING
M
M
M
M
M
M
M
M
M
N
N
N
N
N
N
N
N
N
G
G
G
G
G
G
G
G
G
* Chamber will be filled with sealing when
cable gland is completely assembled.
7. YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
PNA
PNA
Feam Catalogue 01 - 137
Ex Cable Glands
CABLE GLANDS FOR
UNARMOURED CABLES
On Request Accessories:
• Locknuts, Gaskets, PVC Shrouds, Earthing Tags, Sealing (See ACCESSORI bulletin)
Mechanical characteristics
Body / cap OT-58 marine brass (ON) - AISI-316L stainless steel (IX) - *anticorodal aluminium (AL)
Finishes full nickel plating threatment (brass material only)
Rubber rings EDPM rubber- 50-60 shore hardness - Silicon rubber - 60 shore hardness
O-ring silicon rubber - 60 shore hardness
Skid washer nylon 6
Chamber for sealing OT-58 marine brass ("R" version only)
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
APPLICATION
• FOR UNARMOURED CABLES ONLY
• SINGLE COMPRESSION TYPE SUITABLE FOR INDOOR AND OUTDOOR USE
• SINGLE COMPRESSION - ON CABLE (INNER SEALING)
• SEALING WITH PROPER RESIN INTO “CHAMBER OF SEALING” (ON BARRIER TYPE VERSION “R” ONLY)
*ON REQUEST ONLY. PLEASE CONTACT OUR SALES OFFICE FOR MIN QUANTITY TO ORDER
CABLE GLANDS
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex d II C
II 2 G Ex e II
II 2 D Ex tD A21
Ex d IIC / Ex e II
DIP A21
Ex d IIC / Ex e II
DIP A21
AMBIENT TEMPERATURE
-40°C ÷ +90°C (1)
-50°C ÷ +180°C (2)
-40°C ÷ +90°C (1)
-60°C ÷ +180°C (2)
-40°C ÷ +90°C (1)
-60°C ÷ +180°C (2)
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 07 ATEX 0001X POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1; EN 60079-7;
EN 61241-0; EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
(1) EDPM-60 INTERNAL RUBBER RINGS - (2) SILICON-60 INTERNAL RUBBER RINGS
8. YOUR PARTNER FOR SAFETY
Since 1961
PNA
A
C
B
D
1 2
3
4
5 6 7
PNA# 01 M ON
PNA# 03 N IX
PNA-R# 04 N AL
138 - Feam Catalogue 01
CODE ENTRY THREAD SIZE (C)
INNER SHEATH
DIA. (A)
OUTER SHEATH
DIA. (B)
HEXAGON
(D)
MATERIAL
(1)
METRIC
(2)
NPT
(2)
UNI ISO 228
(2)
min
[mm]
max
[mm]
max [mm] [mm]
(3)
PNA#
PNA-R#
00 ISO-M20 1/2"NPT 1/2" 4,0 10,0 16,0 26,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PNA#
PNA-R#
01 ISO-M20 1/2"NPT 1/2" 5,5 13,0 20,0 32,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PNA#
PNA-R#
02 ISO-M25 3/4"NPT 3/4" 10,5 18,0 25,0 36,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PNA#
PNA-R#
03 ISO-M32 1"NPT 1" 15,0 24,0 32,0 45,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PNA#
PNA-R#
04 ISO-M40 1 1/4"NPT 1 1/4" 21,0 30,0 38,0 53,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PNA#
PNA-R#
05 ISO-M50 1 1/2"NPT 1 1/2" 24,0 36,0 44,0 61,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PNA#
PNA-R#
06 ISO-M63 2"NPT 2" 36,0 45,0 54,0 71,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PNA#
PNA-R#
07 ISO-M75 2 1/2"NPT 2 1/2" 45,0 54,0 65,0 84,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PNA#
PNA-R#
08 ISO-M90 3"NPT 3" 52,0 65,0 79,0 101,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
M
M
M
M
M
M
M
M
M
N
N
N
N
N
N
N
N
N
G
G
G
G
G
G
G
G
G
Ex Cable Glands
PNA Cable gland selection table
CABLE GLAND ORDERING
EXAMPLES
LEGEND
= PNA#01MON (NON-BARRIER CABLE GLAND NICKEL PLATED BRASS ISO-M20 THR.)
= PNA#03NIX (NON-BARRIER CABLE GLAND STAINLESS STEEL 1/2”NPT THR.)
= PNA-r#04NON (BARRIER CABLE GLAND NICKEL PLATED BRASS 1 1/4”NPT THR.)
(1) CABLE GLAND TYPE/MODEL PNA# = NON-BARRIER CABLE GLAND - PNA-R# = BARRIER CABLE GLAND
(2) THREADING M = ISO METRIC pitch 1,5mm - N = NPT (ANSI/ASME B1.20.1) - G = UNI ISO-228
(3) CABLE GLAND MATERIAL ON = NICKEL PLATED MARINE BRASS - IN = AISI-316L STAINLESS STEEL - AL = ANTICORODAL ALUMINIUM
REMARK: Due to the development of the national and international specifications and of the technology, the above technical
characteristics showed on this bulletin can be considered as binding on our confirmation only.
SIZE
PNA Dimensional 1. rings for seal
2. inner seal
3. * chamber for sealing
(“R” version only)
4. cable without armour
5. cap
6. body
7. O-RING
* Chamber will be filled with sealing when
cable gland is completely assembled.
9. YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
PNAF
PNAF
Feam Catalogue 01 - 139
Ex Cable Glands
CABLE GLANDS FOR
UNARMOURED CABLES
On Request Accessories:
• Locknuts, Gaskets, PVC Shrouds, Earthing Tags, Sealing (See ACCESSORI bulletin)
Mechanical characteristics
Body / cap OT-58 marine brass (ON) - AISI-316L stainless steel (IX) - * anticorodal aluminium (AL)
Finishes full nickel plating threatment (brass material only)
Rubber rings EDPM rubber- 50-60 shore hardness - Silicon rubber - 60 shore hardness
O-ring silicon rubber - 60 shore hardness
Skid washer nylon 6
Chamber for sealing OT-58 marine brass ("R" version only)
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
APPLICATION
• FOR UNARMOURED CABLES ONLY
• SUITABLE FOR FLEXIBLE CONDUIT COUPLING CONNECTION BY THREADED CAP (UNI ISO 228)
• SINGLE COMPRESSION TYPE SUITABLE FOR INDOOR AND OUTDOOR USE
• SINGLE COMPRESSION - ON CABLE (INNER SEALING)
• SEALING WITH PROPER RESIN INTO "CHAMBER OF SEALING" ( ON BARRIER TYPE VERSION "R" ONLY )
*ON REQUEST ONLY. PLEASE CONTACT OUR SALES OFFICE FOR MIN QUANTITY TO ORDER
(1) EDPM-60 INTERNAL RUBBER RINGS - (2) SILICON-60 INTERNAL RUBBER RINGS
CABLE GLANDS
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex d II C
II 2 G Ex e II
II 2 D Ex tD A21
Ex d IIC / Ex e II
DIP A21
Ex d IIC / Ex e II
DIP A21
AMBIENT TEMPERATURE
-40°C ÷ +90°C (1)
-50°C ÷ +180°C (2)
-40°C ÷ +90°C (1)
-60°C ÷ +180°C (2)
-40°C ÷ +90°C (1)
-60°C ÷ +180°C (2)
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 07 ATEX 0001X POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1; EN 60079-7;
EN 61241-0; EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
10. YOUR PARTNER FOR SAFETY
Since 1961
PNAF
C
A
B
C1
D
1 2
3
4
5 6 7
PNAF# 01 M ON
PNAF# 03 N IX
PNAF-R# 04 N AL
140 - Feam Catalogue 01
Ex Cable Glands
PNAF Cable gland selection table
LEGEND
(1) CABLE GLAND TYPE/MODEL PNAF# = NON-BARRIER CABLE GLAND - PNAF-R# = BARRIER CABLE GLAND
(2) THREADING M = ISO METRIC pitch 1,5mm - N = NPT (ANSI/ASME B1.20.1 - G = UNI ISO-228
(3) CABLE GLAND MATERIAL ON = NICKEL PLATED MARINE BRASS - IN = AISI-316L STAINLESS STEEL - AL = ANTICORODAL ALUMINIUM
(4) FEMALE THREAD UNI ISO-228 FEMALE THREAD SUITABLE FOR FLEXIBLE CONDUIT COUPLING
REMARK: Due to the development of the national and international specifications and of the technology, the above technical
characteristics showed on this bulletin can be considered as binding on our confirmation only.
PNAF Dimensional 1. rings for seal
2. inner seal
3. * chamber for sealing
(“R” version only)
4. cable without armour
5. threaded cap
6. body
7. O-RING
* Chamber will be filled with sealing when
cable gland is completely assembled.
CODE ENTRY THREAD SIZE (C)
INNER
SHEATH DIA
(A)
OUTER
SHEATH
DIA. (B)
FEM.THREAD
(C1)
EXAG.
(D)
MATERIAL
(1)
METRIC
(2)
NPT
(2)
UNI ISO 228
(2)
min
[mm]
max
[mm]
min [mm]
UNI ISO 228
(4)
[mm]
(3)
PNAF#
PNAF-R#
01 ISO-M20 1/2"NPT 1/2" 5,5 13,0 20,0 1/2" 32,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PNAF#
PNAF-R#
02 ISO-M25 3/4"NPT 3/4" 10,5 18,0 25,0 3/4" 36,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PNAF#
PNAF-R#
03 ISO-M32 1"NPT 1" 15,0 24,0 32,0 1" 45,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PNAF#
PNAF-R#
04 ISO-M40 1 1/4"NPT 1 1/4" 21,0 30,0 38,0 1 1/4" 53,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PNAF#
PNAF-R#
05 ISO-M50 1 1/2"NPT 1 1/2" 24,0 36,0 44,0 1 1/2" 61,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PNAF#
PNAF-R#
06 ISO-M63 2"NPT 2" 36,0 45,0 54,0 2" 71,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PNAF#
PNAF-R#
07 ISO-M75 2 1/2"NPT 2 1/2" 45,0 54,0 65,0 2 1/2" 84,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
PNAF#
PNAF-R#
08 ISO-M90 3"NPT 3" 52,0 65,0 79,0 3" 101,0
NICKEL PL.BRASS
STAINLESS STEEL
ALUMINIUM
ON
IX
AL
CABLE GLAND ORDERING
EXAMPLES
= PNAF#01MON (NON-BARRIER CABLE GLAND NICKEL PLATED BRASS ISO-M20 THR.)
= PNAF#03NIX (NON-BARRIER CABLE GLAND STAINLESS STEEL 1/2”NPT THR.)
= PNAF-R#04NON (BARRIER CABLE GLAND NICKEL PLATED BRASS 1 1/4”NPT THR.)
SIZE
M
M
M
M
M
M
M
M
N
N
N
N
N
N
N
N
G
G
G
G
G
G
G
G
11. YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
DL-NW-PTD-ET
DL-NW-PTD-ET
DL
NW
PTD
ET
M
Feam Catalogue 01 - 141
Ex Cable Glands
CABLE GLANDS ACCESORIES
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
APPLICATIONS
Mechanical characteristics
LOCKNUTS
Material nichel plated brass
Finishes full nickel plating threatment
(brass material only)
LOCKNUTS
Are preffered items used in securing cable glands to the gland
plate especially to plastic junction boxes
SHORUDS
For all tipe of glands application where additional protection is
required
SILICONE SEALANT
Is provided for submission of barrier cable glands type-R
GASKETS
Are used to mantain the ip rating across the interface between
the equipment and relevant cable gland
EARTH TAGS
Are used to ensure earth continuity and grounding of cable
armour
SHORUDS
Material PVC
GASKETS
Material nylon 6.0
EARTH TAGS
Material stainless steel
CABLE GLANDS ACCESSORIES
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex d II C
II 2 G Ex e II
II 2 D Ex tD A21
Ex d IIC / Ex e II
DIP A21
Ex d IIC / Ex e II
DIP A21
AMBIENT TEMPERATURE -50°C ÷ +180°C -50°C ÷ +180°C -50°C ÷ +180°C
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 07 ATEX 0001X POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1; EN 60079-7;
EN 61241-0; EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
SILICON
12. YOUR PARTNER FOR SAFETY
Since 1961
DL-NW-PTD-ET
DL0 3/8" 3/8" M16
DL1 1/2" 1/2" M20
DL2 3/4" 3/4" M25
DL3 1" 1" M32
DL4 1-1/4" 1-1/4" M40
DL5 1-1/2" 1-1/2" M50
DL6 2" 2" M75
DL7 2-1/2" 2-1/2" M75
DL8 3" 3" M90
NW0 3/8" 3/8" M16
NW1 1/2" 1/2" M20
NW2 3/4" 3/4" M25
NW3 1" 1" M32
NW4 1-1/4" 1-1/4" M40
NW5 1-1/2" 1-1/2" M50
NW6 2" 2" M75
NW7 2-1/2" 2-1/2" M75
NW8 3" 3" M90
M20 20 C
M25 25 C
M32 32 C
M40 40 C
M50 50 C
M63 63 C
PTD0 3/8" 3/8" M16
PTD1 1/2" 1/2" M20
PTD2 3/4" 3/4" M25
PTD3 1" 1" M32
PTD4 1-1/4" 1-1/4" M40
PTD5 1-1/2" 1-1/2" M50
PTD6 2" 2" M75
PTD7 2-1/2" 2-1/2" M75
PTD8 3" 3" M90
ET0 3/8" 3/8" M16
ET1 1/2" 1/2" M20
ET2 3/4" 3/4" M25
ET3 1" 1" M32
ET4 1-1/4" 1-1/4" M40
ET5 1-1/2" 1-1/2" M50
ET6 2" 2" M75
ET7 2-1/2" 2-1/2" M75
ET8 3" 3" M90
0 2
1 3
2 6
3 15
4 20
5 30
6 50
7 100
8 150
D
3s
s
DL
PTD ET
NW M
142 - Feam Catalogue 01
Ex Cable Glands
CABLE GLANDS ACCESSORIES – Technical Features
REMARK:
Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.
LOCKNUTS
DETAIL
A
THREADS / SIZE
TYPE NPT UNI-228 ISO
GASKETS
DETAIL
B
THREADS / SIZE
TYPE NPT UNI-228 ISO
WASHERS
TYPE ØD [mm] DETAIL
SHROUDS
DETAIL
D
THREADS / SIZE
TYPE NPT UNI-228 ISO
EARTHS TAGS
DETAIL
E
THREADS / SIZEE
TYPE NPT UNI-228 ISO
SILICON SEALANT
CABLE GLANDS
SIZE
Q.TY SEALING
[ml]
SEALING
Det.A
Det.D Det.E
Det.B Det.C