This document provides information on the Series 6149/2 LED inspection light, including:
- It uses high-power LEDs and has an extremely long service life. It is suitable for both inspection and machine lighting.
- It is available in versions for 12V DC, 24-48V AC/DC, and 110-240V AC/DC power. All have IP66/67 protection.
- Accessories include mounting brackets, wire guards, and plug options. Dimensions and technical specifications are provided.
- The light has anti-roll design, lockable suspension hooks, and delivers over 600 lumens of bright light for inspection needs. It is certified for use in hazardous locations.
MCB Fuji: thiết bị đóng cắt Fuji
Beeteco.com là trang mua sắm trực tuyến thiết bị điện - Tự động hóa uy tín tại Việt Nam.
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Số 7 Đại Lộ Độc Lập, KCN Sóng Thần 1, P. Dĩ An, Tx. Dĩ An, Bình Dương
www.facebook.com/beeteco
Tel: 0650 3617 012
DĐ: 0904 676 925
Hazardous Area Flood Lights - ATEX Certified
Zone 2 Floodlights
150W SON, 250W SON, 400W SON, 500W Tungsten Halide
Petrel hazardous area (ATEX certified) Zone 2 floodlights are extensively specified for Ex e lighting applications.
Petrel Hazardous Area Zone 2 Flood Lighting (ATEX) - Ex
Zone 2 Flood Light
Petrel hazardous area Zone 2 floodlights are made from die cast aluminium and incorporate assymetrical reflector as standard - Zone 2 floodlights can be fitted with a range of control gear suitable for lamps from 150w to 500w. Petrel ZT hazardous area Zone 2 floodlight is ATEX certified for use with SON, MBF and tungsten lamps.
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
Benefits
Symmetrical reflector allows maximum directional light output
Graduated mounting bracket allows for consistent installation angle for multiple units
Easy re-lamping via hinged front section
Options
Sodium, metal halide, and tungsten lamp options
Other colours available
Petrel ZT150 (150W SON), ZT250 (250W SON), ZT400 (400W SON)
Petrel ZT500 (500W tungsten halide)
Features
230v 50Hz standard
-20°C to +30°C standard supply subject to ambient temperature requirements.
Tubular : SON, MBI, Tungsten. 70w to 500w Symmetrical reflector fitted to all versions (lamps not provided).
Hazardous Area Zones Classification
Zone 2 - where flammable atmosphere is not likely to occur during normal operation and if it does will only exist for short period of time, typically less than 10 hours per year.
Thorne & Derrick UK are official stockists and distributors for the Petrel Explosion Proof and Hazardous Area Lighting ranges for Zone 1 and Zone 2 lighting installations with ATEX certification – this includes hazardous area fluorescent, bulkhead, floodlight and wellglass lighting. EX Lighting Products from Petrel Hazardous Area Electrical Equipment : Ex de Well Glass, Ex d Emergency Flourescent Luminaire, Ex de Bulkhead, Ex de Zone 1 Floodlight, Zone 2 Floodlight, Ex ed Standard & Emergency Flourescent Luminaire, Zone 2 Standard & Emergency Flourescent Luminaire, Ex d Flourescent Luminaire, Zone 2 Bulkhead Luminaire, Ex ed Recessed Zone 1 Flourescent Luminaire.
Zone 2 Floodlights
ATEX Certified Hazardous Area Floodlights
Petrel hazardous area (ATEX certified) Zone 2 floodlights are extensively specified for Ex e lighting applications.
Petrel ZT150 - 150W - SON Floodlight for Zone 2 Hazardous Areas - ATEX Group II Cat 3GD
Petrel ZT Zone 2 Floodlights provide following benefits :
* Hinged lid opening for safe re-lamping in hazardous areas
* Graduated angle bracket for fast, accurate installations
* Lightweight but strong die cast aluminium floodlight
* Asymmetric reflector for maximum downward light output
Petrel Hazardous Area Zone 2 Flood Lighting (ATEX) - Ex
Zone 2 Flood Light
Petrel hazardous area Zone 2 floodlights are made from die cast aluminium and incorporate assymetrical reflector as standard - Zone 2 floodlights can be fitted with a range of control gear suitable for lamps from 150w to 500w. Petrel ZT hazardous area Zone 2 floodlight is ATEX certified for use with SON, MBF and tungsten lamps.
Hazardous Area Zones Classification
Zone 2 - where flammable atmosphere is not likely to occur during normal operation and if it does will only exist for short period of time, typically less than 10 hours per year.
ATEX Certified Lighting for Hazardous Areas Zones 1 & Zones 2
ATEX is the name given to a set of European Directives relating to Hazardous Area Electrical & Lighting Equipment Installations (Flammable Atmospheres) to avoid industrial accident or incident, this cover hazardous area lighting Zone 1 and Zone 2 installations. ATEX Directive 94/9/EC (ATEX 95), is a directive adopted by the EU under the “New Approach” strategy. The “New Approach” ATEX directive supersedes the “Old Approach” ATEX Directive, the Potentially Explosive Atmospheres Directive, 76/117/EEC – ATEX 94/9/EC (ATEX 95) facilitates free trade in the EC for hazardous area lighting and electrical equipment intended to be used in potentially explosive atmospheres. ATEX Directive 94/9/EC (ATEX 95) covers “Electrical Equipment” used in hazardous areas with potentially explosive atmospheres created by presence of gases, vapours, mists or dusts.
Thorne & Derrick UK are specialist distributors of Petrel Hazardous Area Lighting ranges providing expert technical guidance, site surveys, competitive quotations, ex stock delivery and a comprehensive lighting design service - this includes hazardous area Zone 1 and Zone 2 (ATEX) fluorescent, recessed, portable, bulkhead, wellglass and floodlights.
Petrel Hazardous Area Lighting is a specialist manufacturer of hazardous area lighting for the oil, gas, petro-chemical, pharmaceutical, offshore and marine industries worldwide offering the design and production of lighting products for Zone 1, 2, 21 & 22, Gas and Dust - this includes ATEX and IEC Ex Explosion Proof Exe & Ex d Lighting ranges : fluorescent, recessed, helideck, LED floodlight, bulkhead and well glass.
MCB Fuji: thiết bị đóng cắt Fuji
Beeteco.com là trang mua sắm trực tuyến thiết bị điện - Tự động hóa uy tín tại Việt Nam.
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Số 7 Đại Lộ Độc Lập, KCN Sóng Thần 1, P. Dĩ An, Tx. Dĩ An, Bình Dương
www.facebook.com/beeteco
Tel: 0650 3617 012
DĐ: 0904 676 925
Hazardous Area Flood Lights - ATEX Certified
Zone 2 Floodlights
150W SON, 250W SON, 400W SON, 500W Tungsten Halide
Petrel hazardous area (ATEX certified) Zone 2 floodlights are extensively specified for Ex e lighting applications.
Petrel Hazardous Area Zone 2 Flood Lighting (ATEX) - Ex
Zone 2 Flood Light
Petrel hazardous area Zone 2 floodlights are made from die cast aluminium and incorporate assymetrical reflector as standard - Zone 2 floodlights can be fitted with a range of control gear suitable for lamps from 150w to 500w. Petrel ZT hazardous area Zone 2 floodlight is ATEX certified for use with SON, MBF and tungsten lamps.
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
Benefits
Symmetrical reflector allows maximum directional light output
Graduated mounting bracket allows for consistent installation angle for multiple units
Easy re-lamping via hinged front section
Options
Sodium, metal halide, and tungsten lamp options
Other colours available
Petrel ZT150 (150W SON), ZT250 (250W SON), ZT400 (400W SON)
Petrel ZT500 (500W tungsten halide)
Features
230v 50Hz standard
-20°C to +30°C standard supply subject to ambient temperature requirements.
Tubular : SON, MBI, Tungsten. 70w to 500w Symmetrical reflector fitted to all versions (lamps not provided).
Hazardous Area Zones Classification
Zone 2 - where flammable atmosphere is not likely to occur during normal operation and if it does will only exist for short period of time, typically less than 10 hours per year.
Thorne & Derrick UK are official stockists and distributors for the Petrel Explosion Proof and Hazardous Area Lighting ranges for Zone 1 and Zone 2 lighting installations with ATEX certification – this includes hazardous area fluorescent, bulkhead, floodlight and wellglass lighting. EX Lighting Products from Petrel Hazardous Area Electrical Equipment : Ex de Well Glass, Ex d Emergency Flourescent Luminaire, Ex de Bulkhead, Ex de Zone 1 Floodlight, Zone 2 Floodlight, Ex ed Standard & Emergency Flourescent Luminaire, Zone 2 Standard & Emergency Flourescent Luminaire, Ex d Flourescent Luminaire, Zone 2 Bulkhead Luminaire, Ex ed Recessed Zone 1 Flourescent Luminaire.
Zone 2 Floodlights
ATEX Certified Hazardous Area Floodlights
Petrel hazardous area (ATEX certified) Zone 2 floodlights are extensively specified for Ex e lighting applications.
Petrel ZT150 - 150W - SON Floodlight for Zone 2 Hazardous Areas - ATEX Group II Cat 3GD
Petrel ZT Zone 2 Floodlights provide following benefits :
* Hinged lid opening for safe re-lamping in hazardous areas
* Graduated angle bracket for fast, accurate installations
* Lightweight but strong die cast aluminium floodlight
* Asymmetric reflector for maximum downward light output
Petrel Hazardous Area Zone 2 Flood Lighting (ATEX) - Ex
Zone 2 Flood Light
Petrel hazardous area Zone 2 floodlights are made from die cast aluminium and incorporate assymetrical reflector as standard - Zone 2 floodlights can be fitted with a range of control gear suitable for lamps from 150w to 500w. Petrel ZT hazardous area Zone 2 floodlight is ATEX certified for use with SON, MBF and tungsten lamps.
Hazardous Area Zones Classification
Zone 2 - where flammable atmosphere is not likely to occur during normal operation and if it does will only exist for short period of time, typically less than 10 hours per year.
ATEX Certified Lighting for Hazardous Areas Zones 1 & Zones 2
ATEX is the name given to a set of European Directives relating to Hazardous Area Electrical & Lighting Equipment Installations (Flammable Atmospheres) to avoid industrial accident or incident, this cover hazardous area lighting Zone 1 and Zone 2 installations. ATEX Directive 94/9/EC (ATEX 95), is a directive adopted by the EU under the “New Approach” strategy. The “New Approach” ATEX directive supersedes the “Old Approach” ATEX Directive, the Potentially Explosive Atmospheres Directive, 76/117/EEC – ATEX 94/9/EC (ATEX 95) facilitates free trade in the EC for hazardous area lighting and electrical equipment intended to be used in potentially explosive atmospheres. ATEX Directive 94/9/EC (ATEX 95) covers “Electrical Equipment” used in hazardous areas with potentially explosive atmospheres created by presence of gases, vapours, mists or dusts.
Thorne & Derrick UK are specialist distributors of Petrel Hazardous Area Lighting ranges providing expert technical guidance, site surveys, competitive quotations, ex stock delivery and a comprehensive lighting design service - this includes hazardous area Zone 1 and Zone 2 (ATEX) fluorescent, recessed, portable, bulkhead, wellglass and floodlights.
Petrel Hazardous Area Lighting is a specialist manufacturer of hazardous area lighting for the oil, gas, petro-chemical, pharmaceutical, offshore and marine industries worldwide offering the design and production of lighting products for Zone 1, 2, 21 & 22, Gas and Dust - this includes ATEX and IEC Ex Explosion Proof Exe & Ex d Lighting ranges : fluorescent, recessed, helideck, LED floodlight, bulkhead and well glass.
Catalog đèn báo nút nhấn công tắc IDEC (Nhật Bản) - dòng TWCTY TNHH HẠO PHƯƠNG
Công ty Cổ phần Hạo Phương xin gửi đến quý khách hàng Catalog về đèn báo, nút nhấn, công tắc xoay Idec (Nhật Bản) phi 22 dòng TW. Catalog chứa đầy đủ thông tin về sản phẩm, kích thước và những lưu ý để sử dụng thiết bị hiệu quả.
Điểm đặc biệt của đèn báo IDEC phi 22 là có thể dễ dàng chuyển đổi từ phi 22 sang phi 25, điều mà hiếm có sản phẩm nào trên thị trường có thể làm được.
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.vn
200W 24V Waterproof LED Power supplies for outdoor lighting fixtures, LED tunel lights, LED floodlights, led projector,led wall washer lights, LED linear lighting........illuminated signs, slim light box, facade lighting, led growlights....... IP67 Waterproof level, full sealed with silicon gel. used for wet and damp conditions.
Hioki FT6031-03 Earth Tester, Ground Resistance Tester Dustproof and Waterproof ROnex International
Hioki FT6031-03 Earth Tester, Ground Resistance Tester, Dustproof and Waterproof in Bangladesh
Product Features:
IP67 protected
Test all ground types from Class A to Class D with a single meter
Wide 0 to 2000ohm measurement range
Minimize cabling time with innovative earthing rods and cable winder
Nexans Euromold Connectors Interface D 600 Series
Nexans Euromold 675LR Connector
1250A 11kV Dead Break Connectors 35-800sqmm
Nexans Euromold 675LR connector suits 11kV/12kV polymeric insulated cables (XLPE EPR), rated up to 1250amps with copper or aluminium conductors 35-800sqmm.
Interface type D Nexans Euromold 5/8" bolted tee connector, for high voltage cable connecting and termination applications up to 24kV. 1250amp (copper stud) application separable connector is designed to connect polymeric (XLPE EPR) cables to a 5/8" copper, 600 series bushings.
Catalog đèn báo nút nhấn công tắc IDEC (Nhật Bản) - dòng TWCTY TNHH HẠO PHƯƠNG
Công ty Cổ phần Hạo Phương xin gửi đến quý khách hàng Catalog về đèn báo, nút nhấn, công tắc xoay Idec (Nhật Bản) phi 22 dòng TW. Catalog chứa đầy đủ thông tin về sản phẩm, kích thước và những lưu ý để sử dụng thiết bị hiệu quả.
Điểm đặc biệt của đèn báo IDEC phi 22 là có thể dễ dàng chuyển đổi từ phi 22 sang phi 25, điều mà hiếm có sản phẩm nào trên thị trường có thể làm được.
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.vn
200W 24V Waterproof LED Power supplies for outdoor lighting fixtures, LED tunel lights, LED floodlights, led projector,led wall washer lights, LED linear lighting........illuminated signs, slim light box, facade lighting, led growlights....... IP67 Waterproof level, full sealed with silicon gel. used for wet and damp conditions.
Hioki FT6031-03 Earth Tester, Ground Resistance Tester Dustproof and Waterproof ROnex International
Hioki FT6031-03 Earth Tester, Ground Resistance Tester, Dustproof and Waterproof in Bangladesh
Product Features:
IP67 protected
Test all ground types from Class A to Class D with a single meter
Wide 0 to 2000ohm measurement range
Minimize cabling time with innovative earthing rods and cable winder
Nexans Euromold Connectors Interface D 600 Series
Nexans Euromold 675LR Connector
1250A 11kV Dead Break Connectors 35-800sqmm
Nexans Euromold 675LR connector suits 11kV/12kV polymeric insulated cables (XLPE EPR), rated up to 1250amps with copper or aluminium conductors 35-800sqmm.
Interface type D Nexans Euromold 5/8" bolted tee connector, for high voltage cable connecting and termination applications up to 24kV. 1250amp (copper stud) application separable connector is designed to connect polymeric (XLPE EPR) cables to a 5/8" copper, 600 series bushings.
Nexans Euromold Connectors Interface D 600 Series
Nexans Euromold 650LR Connector
800A 11kV Dead Break Connectors 35-630sqmm
Interface type D Nexans Euromold 5/8" bolted tee connector, for high voltage cable connecting and termination applications up to 24kV. 800amp (aluminium stud) application separable connector is designed to connect polymeric (XLPE EPR) cables to a 5/8" aluminium stud, 600 series bushings.
Nexans Euromold K650LR connector suits 24kV polymeric insulated cables (XLPE EPR), rated up to 800amps with copper or aluminium conductors 35-630sqmm.
Interface type D Nexans Euromold 5/8" bolted tee connector, for high voltage cable connecting and termination applications up to 24kV. 800amp (aluminium stud) application separable Nexans Euromold connector is designed to connect polymeric (XLPE EPR) cables to a 5/8" aluminium stud, 600 series bushings.
Nexans Euromold 600 series screened separable connectors are EPDM pre-moulded, high voltage cable terminations for 6.6kV, 11kV, 15kV and 24kV electrical equipment including switchgear, transformers and motors.
Nexans Euromold 600 series separable connectors include Nexans Euromold bolted tee connectors and Nexans Euromold bushings (oil and air insulated) for electrical equipment up to 24kV - 1250A. Nexans Euromold 600 series connectors are specified to terminate and connect polymeric (XLPE or EPR) screened (copper tape and wire) cables to ANSI-style Interface Type D (800amp) bushings with either copper or aluminium 5/8" bolted connection.
Ls catalog thiet bi dien electric products e 1104Dien Ha The
Catalog LS, Catalog,
Catalog Thiết Bị Điện LS, Catalog Thiết Bị Điện,
http://dienhathe.com,
Chi tiết các sản phẩm khác của LS tại https://dienhathe.com
Xem thêm các Catalog khác của LS tại https://dienhathe.info
Để nhận báo giá sản phẩm LS vui lòng gọi: 0907.764.966
Ls catalog thiet bi dien electric products e 1104_dienhathe.vnDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.org
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.org
Catalog LS, Catalog,
Catalog Thiết Bị Điện LS, Catalog Thiết Bị Điện,
http://dienhathe.com,
Chi tiết các sản phẩm khác của LS tại https://dienhathe.com
Xem thêm các Catalog khác của LS tại https://dienhathe.info
Để nhận báo giá sản phẩm LS vui lòng gọi: 0907.764.966
Euromold Connectors 400 Series Interface Type C Bushing - 630Amp
* Connector Type : M16 Bolted Copper Insert
* Voltage Range : 11/12kV-33/36kV
* Current Rating : 630amps
* Specification : CENELEC EN50180 & EN50181
Euromold 430TB Elbow Connectors are used with 400 Series Interface C Bushing.
Nexans Euromold tee connectors are designed for terminating high voltage XLPE power cables into compact switchgear to make optimum use of limited installation space.
Nexans, the worldwide leader in the cable industry, has extended its well-proven range of compact high voltage (HV) connectors with two new tee-shaped connectors designed specifically for use with compact switchgear and transformers now being specified for wind turbine applications. The Nexans Euromold M430TB connector is for use with higher voltages (up to 33-36kV) and the M434TB connector is for higher currents (up to 1,250 A).
Trend Towards Compact Switchgear for Wind Turbines
The growing trend towards using ever more compact high voltage switchgear in wind turbines has resulted in smaller cable boxes, limiting the space available for connectors. Nexans has responded to this challenge by developing its new asymmetric tee-shape connectors to create a compact connection solution. This now enables two cables to be connected in the same space required for one cable using a traditional non-compact connector. As well as being ideal for all applications where space is a limiting factor, the Nexans compact connectors also enable users to increase the capacity of an existing installation.
EPDM Jacket: A Key Design Feature for Safety and Reliability
The Nexans Euromold M430TB and the M434TB are separable tee-shape bolted connectors designed to connect high voltage polymer-insulated cable to wind turbine equipment such as switchgear and transformers- they can also be used for cable to cable connections with the appropriate mating parts. A key design feature is the thick (3 mm) EPDM (Ethylene Propylene Diene Monomer) rubber conductive insulation jacket that provides a total safe to touch screen for personnel safety, this is both more reliable and longer lasting than the painted silicone rubber insulation used in many connectors.
400 Series Interface C Compact Nexans Euromold Cable Connectors and Bushings connect and terminate HV cables to Interface C bushings on switchgear and transformers.
Nexans Euromold provide high voltage cable accessories to suit the 7 main bushing interfaces : A, B, C (Compact), C (Symmetrical), D, E and F.
Nexans Euromold cable joints, cable terminations, epoxy bushings, angled (elbow) and straight plug-in or bolted separable connectors for connecting, jointing and terminating high voltage cables.
400 Series Interface C Compact Nexans Euromold Cable Connectors and Bushings connect and terminate HV cables to Interface C bushings on switchgear and transformers.
Nexans Euromold provide high voltage cable accessories to suit the 7 main bushing interfaces : A, B, C (Compact), C (Symmetrical), D, E and F.
Nexans Euromold cable joints, cable terminations, epoxy bushings, angled (elbow) and straight plug-in or bolted separable connectors for connecting, jointing and terminating high voltage cables.
The Nexans Euromold compact version screened separable connector is suitable for high voltage HV cable termination up to 33kV. Interface Type C Euromold M16 bolted tee connectors up to 33kV are designed to connect and terminate polymeric (XLPE EPR) cables to M16 bolted 400 series equipment bushings. Nexans Euromold connectors are supplied in sets of three phases.
Nexans Euromold Kit Contents: 3 x connector housings, 3 x size sensitive cable reducers, 3 x conductor contact lug, 3 x clamping screws and 3 x insulating plugs & caps.
Aswich Electrical:EDS1 DC Isolator Cage Type (1200V 16A~32A)Aswich Electrical
Aswich Electrical:EDS1 series isolation switch is suitable for a power system with rated voltage DC1500V or below and rated current 50A or below. The product can be used for infrequent switching-on and switching-off and can disconnect 1 ~ 4 MPPT lines at the same time. It is especially suitable for isolating lines in HVDC transmission and distribution systems, such as cutting off the high voltage direct current between solar panels and inverters.
contact@aswich.com
Similar to Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1, Zone 2, Zone 21 & Zone 22 (20)
Isolation Procedures for Safe Working on Electrical Systems and Equipment by the JIB | solation Procedures for Safe Working on Electrical Systems and Equipment
This chart shows the safe isolation procedure that you should use when working on electrical systems and equipment.
You'll receive a printed copy of this from your Training Provider, but it's also here as a handy reference to keep electronically.
THE RULES OF SAFE ISOLATION ARE:
Obtain permission to start work (a Permit may be required in some situations)
Identify the source(s) of supply using an approved voltage indicator or test lamp
Prove that the approved voltage indicator or test lamp is functioning correctly
Isolate the supply(s)
Secure the isolation
Prove the system/equipment is DEAD using an approved voltage indicator or test lamp
Prove that the approved voltage indicator or test lamp is functioning correctly
Put up warning signs to tell other people that the electrical installation has been isolated
Once the system/equipment is proved DEAD, work can begin
Uploaded by THORNE & DERRICK LV HV Jointing, Earthing, Substation & Electrical Eqpt | Explosive Atmosphere Experts & ATEX IECEx.
THORNE & DERRICK based in the UK are international distributors of LV, MV & HV Cable Installation, Jointing, Substation & Electrical Equipment.
Since 1985, T&D have established an international reputation based on SERVICE | INTEGRITY | TRUST.
Contact us for 3M, ABB, Alroc, AN Wallis, CATU, Cembre, Centriforce, CMP, CSD, Elastimold, Ellis Patents, Emtelle, Euromold, Filoform , Furse, Lucy Electric & Zodion, Nexans, Pfisterer, Polypipe, Prysmian, Roxtec, Sicame, WT Henley.
The Art of the Pitch: WordPress Relationships and SalesLaura Byrne
Clients don’t know what they don’t know. What web solutions are right for them? How does WordPress come into the picture? How do you make sure you understand scope and timeline? What do you do if sometime changes?
All these questions and more will be explored as we talk about matching clients’ needs with what your agency offers without pulling teeth or pulling your hair out. Practical tips, and strategies for successful relationship building that leads to closing the deal.
Kubernetes & AI - Beauty and the Beast !?! @KCD Istanbul 2024Tobias Schneck
As AI technology is pushing into IT I was wondering myself, as an “infrastructure container kubernetes guy”, how get this fancy AI technology get managed from an infrastructure operational view? Is it possible to apply our lovely cloud native principals as well? What benefit’s both technologies could bring to each other?
Let me take this questions and provide you a short journey through existing deployment models and use cases for AI software. On practical examples, we discuss what cloud/on-premise strategy we may need for applying it to our own infrastructure to get it to work from an enterprise perspective. I want to give an overview about infrastructure requirements and technologies, what could be beneficial or limiting your AI use cases in an enterprise environment. An interactive Demo will give you some insides, what approaches I got already working for real.
Builder.ai Founder Sachin Dev Duggal's Strategic Approach to Create an Innova...Ramesh Iyer
In today's fast-changing business world, Companies that adapt and embrace new ideas often need help to keep up with the competition. However, fostering a culture of innovation takes much work. It takes vision, leadership and willingness to take risks in the right proportion. Sachin Dev Duggal, co-founder of Builder.ai, has perfected the art of this balance, creating a company culture where creativity and growth are nurtured at each stage.
Key Trends Shaping the Future of Infrastructure.pdfCheryl Hung
Keynote at DIGIT West Expo, Glasgow on 29 May 2024.
Cheryl Hung, ochery.com
Sr Director, Infrastructure Ecosystem, Arm.
The key trends across hardware, cloud and open-source; exploring how these areas are likely to mature and develop over the short and long-term, and then considering how organisations can position themselves to adapt and thrive.
UiPath Test Automation using UiPath Test Suite series, part 4DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 4. In this session, we will cover Test Manager overview along with SAP heatmap.
The UiPath Test Manager overview with SAP heatmap webinar offers a concise yet comprehensive exploration of the role of a Test Manager within SAP environments, coupled with the utilization of heatmaps for effective testing strategies.
Participants will gain insights into the responsibilities, challenges, and best practices associated with test management in SAP projects. Additionally, the webinar delves into the significance of heatmaps as a visual aid for identifying testing priorities, areas of risk, and resource allocation within SAP landscapes. Through this session, attendees can expect to enhance their understanding of test management principles while learning practical approaches to optimize testing processes in SAP environments using heatmap visualization techniques
What will you get from this session?
1. Insights into SAP testing best practices
2. Heatmap utilization for testing
3. Optimization of testing processes
4. Demo
Topics covered:
Execution from the test manager
Orchestrator execution result
Defect reporting
SAP heatmap example with demo
Speaker:
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
State of ICS and IoT Cyber Threat Landscape Report 2024 previewPrayukth K V
The IoT and OT threat landscape report has been prepared by the Threat Research Team at Sectrio using data from Sectrio, cyber threat intelligence farming facilities spread across over 85 cities around the world. In addition, Sectrio also runs AI-based advanced threat and payload engagement facilities that serve as sinks to attract and engage sophisticated threat actors, and newer malware including new variants and latent threats that are at an earlier stage of development.
The latest edition of the OT/ICS and IoT security Threat Landscape Report 2024 also covers:
State of global ICS asset and network exposure
Sectoral targets and attacks as well as the cost of ransom
Global APT activity, AI usage, actor and tactic profiles, and implications
Rise in volumes of AI-powered cyberattacks
Major cyber events in 2024
Malware and malicious payload trends
Cyberattack types and targets
Vulnerability exploit attempts on CVEs
Attacks on counties – USA
Expansion of bot farms – how, where, and why
In-depth analysis of the cyber threat landscape across North America, South America, Europe, APAC, and the Middle East
Why are attacks on smart factories rising?
Cyber risk predictions
Axis of attacks – Europe
Systemic attacks in the Middle East
Download the full report from here:
https://sectrio.com/resources/ot-threat-landscape-reports/sectrio-releases-ot-ics-and-iot-security-threat-landscape-report-2024/
Accelerate your Kubernetes clusters with Varnish CachingThijs Feryn
A presentation about the usage and availability of Varnish on Kubernetes. This talk explores the capabilities of Varnish caching and shows how to use the Varnish Helm chart to deploy it to Kubernetes.
This presentation was delivered at K8SUG Singapore. See https://feryn.eu/presentations/accelerate-your-kubernetes-clusters-with-varnish-caching-k8sug-singapore-28-2024 for more details.
"Impact of front-end architecture on development cost", Viktor TurskyiFwdays
I have heard many times that architecture is not important for the front-end. Also, many times I have seen how developers implement features on the front-end just following the standard rules for a framework and think that this is enough to successfully launch the project, and then the project fails. How to prevent this and what approach to choose? I have launched dozens of complex projects and during the talk we will analyze which approaches have worked for me and which have not.
JMeter webinar - integration with InfluxDB and GrafanaRTTS
Watch this recorded webinar about real-time monitoring of application performance. See how to integrate Apache JMeter, the open-source leader in performance testing, with InfluxDB, the open-source time-series database, and Grafana, the open-source analytics and visualization application.
In this webinar, we will review the benefits of leveraging InfluxDB and Grafana when executing load tests and demonstrate how these tools are used to visualize performance metrics.
Length: 30 minutes
Session Overview
-------------------------------------------
During this webinar, we will cover the following topics while demonstrating the integrations of JMeter, InfluxDB and Grafana:
- What out-of-the-box solutions are available for real-time monitoring JMeter tests?
- What are the benefits of integrating InfluxDB and Grafana into the load testing stack?
- Which features are provided by Grafana?
- Demonstration of InfluxDB and Grafana using a practice web application
To view the webinar recording, go to:
https://www.rttsweb.com/jmeter-integration-webinar
From Daily Decisions to Bottom Line: Connecting Product Work to Revenue by VP...
Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1, Zone 2, Zone 21 & Zone 22
1. E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
Inspection Light LED
Series 6149/2
www.stahl.de
Lighting E2/12014-10-06·EK00·III·en
Series 6149/2 E2
14348E00
WebCode 6149B
> Extremely long service life
due to LED used
> Also suitable for
machine lighting
> Anti-roll design in the grip
> Lockable suspension hooks
> For 110 ... 240 V AC / DC,
24 ... 48 V AC / DC
or 12 V DC
> High power LEDs including
driver in innovative design
ATEX / IECEx
Zone 0 1 2 20 21 22
For use in x x x x
2. Inspection Light LED
Series 6149/2
Lighting 2014-10-06·EK00·III·enE2/2
Selection Table
Version Nominal voltage Temperature
class at Ta =
Max. surface
temperature
Order number Weight
40 °C 60 °C TO max at
Ta = 40 °C
TO max. at
Ta = 60 °C
kg
Inspection light LED
Series 6149
12 V DC T4 – – 100 °C – – 6149/2-2211-5010 1.400
24 ... 48 V AC / DC;
50 / 60 Hz
T4 T4 100 °C 100 °C 6149/2-3211-5010 1.400
24 ... 48 V AC / DC;
50 / 60 Hz
T6 – – 80° C – – 6149/2-3411-5010 1.400
110 ... 240 V AC / DC;
50 / 60 Hz
T4 T4 100 °C 100 °C 6149/2-5211-5010 1.400
110 ... 240 V AC / DC;
50 / 60 Hz
T6 – – 80° C – – 6149/2-5411-5010 1.400
Order Number Supplement
Wire guard without wire guard 6149/.-...-...0
with wire guard 6149/.-...-...1
Note - The inspection light is delivered with a 5 m connecting cable (other lengths on request)
- The inspection light is delivered without plug and wire guard. Specify the plug on order
(see Accessories and Spare Parts).
Explosion Protection
Global (IECEx)
Gas and dust IECEx PTB 07.0018
Ex d IIC T.* Gb
Ex tb IIIC T... °C*
Europe (ATEX)
Gas and dust PTB 07 ATEX 1009
E II 2 G Ex d IIC T.* Gb
E II 2 D Ex tb IIIC T...°C* Db
* surface temperature and temperature class see selection table
Certificates and approvals
Certificates ATEX, IECEx, Brazil (UL do Brasil), Kazakhstan (GOST-K), Russia (GOST-R), Belarus (GOST-B)
Technical Data
Electrical Data
Version 6149/2-2 (12V) 6149/2-3 (24 ... 48 V) 6149/2-5 (110 ... 240 V)
Rated operational voltage 12 ± 10 % V DC 24 ... 48 ± 10 % V AC / DC;
50 / 60 Hz
110 ... 240 ± 10 % V AC / DC ;
50 / 60 Hz
Nominal operational
current
Luminous Characteristics
Version 6149/2-2 (12V) 6149/2-3 (24 ... 48 V) 6149/2-5 (110 ... 240 V)
Lamps LED - typ. 6000K LED - typ. 6000K LED - typ. 6000K
Luminous flux ca. 600 lm ca. 600 lm ca. 670 lm
Luminous intensity 253 Lux in 1m distance 253 Lux in 1m distance 285 Lux in 1m distance
Ambient Conditions
Version 6149/2-2 (12V) 6149/2-3 (24 ... 48 V) 6149/2-5 (110 ... 240 V)
Ambient temperature - 40 ... + 40 °C T4: - 40 ... + 60 °C
T6: - 40 ... + 40 °C
T4: - 30 ... + 60 °C
T6: - 30 ... + 40 °C
Mechanical Data
Degree of protection IP66 / IP67
Protection class II
Material
Enclosure tube Polycarbonate
Grip Aluminium
Sealing cap Aluminium
Rubber grip NBR / PVC (EPDM)
Suspension hook NBR / PVC (EPDM)
12 V 1,3 A 24 V AC / DC 0.7 A
48 V AC / DC 0.3 A
110 V AC 0.13 A
240 V AC 0.07 A
3. E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
Inspection Light LED
Series 6149/2
Lighting E2/32014-10-06·EK00·III·en
Mounting / Installation
Cable glands CMP cable gland for rubber case-, Thermflex- and wire mesh lead
Connecting cable Standard:
connecting cable, 5 m, type H07RN-F, d 7.7 ... 10 mm, 2 x 1 mm2
Optional:
Gifas Thermoflex cable, 5 m, Type HXSLHXÖ-J, d 7.7 ... 10 mm, 2 x 1.5 mm2
Helukabel with steel wire screening, Type SY-JZ, 2 x 1.5 mm2
Accessories and Spare Parts
Designation Illustration Description Art. no. Weight
kg
Mounting bracket
04880E00
Mounting bracket of galvanised sheet steel 120535 0.050
Mounting bracket and
magnet
04885E00
Mounting bracket of galvanised sheet steel and magnet 120536 0.100
Wire guard
04888E00
Stainless steel wire guard for additional
mechanical protection
120509 0.170
Plug
04923E00
8570/12-304 3 pins, 100 ... 130 V, 50 / 60 Hz, 16 A 150599 0.420
8570/12-306 3 pins, 200 ... 250 V, 50 / 60 Hz, 16 A 150579 0.420
04922E00
8575/12-100 2 pins, 20 ... 25 V, 16 A 151545 0.220
8575/12-110 2 pins, 20 ... 25 V DC, 16 A 151553 0.220
12214E00
8575/12-200 3 pins, 20 ... 25 V, 16 A 151486 0.230
8575/12-212 3 pins, 40 ... 50 V, 16 A 151496 0.220
Technical Data
4. Inspection Light LED
Series 6149/2
Lighting 2014-10-06·EK00·III·enE2/4
Dimensional Drawings (All Dimensions in mm) - Subject to Alterations
03714E00 04925E00
Inspection light without wire guard Inspection light with wire guard
04926E00 04927E00
Mounting bracket Mounting bracket and magnet
We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice.
The illustrations cannot be considered binding.
595
180
302
Ø52
Ø40
Ø62
595
180
302
Ø52
Ø40
Ø62
15
Ø
4
12,7
54,5
80,2
12,788,1
54,5
Ø 25