SlideShare a Scribd company logo
1 of 94
Download to read offline
LIGHTING FIXTURES FOR
FLUORESCENT TUBE LAMPS

Explosion Proof Electrical Equipment

EVF

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D

LIGHTING FIXTURES
ATEX 94/9/EC

GOST-R (RTR / RTN)

GOST-K

1Ex d IIC T5/T4
DIP A21 TA (100…135)°C

1Ex d IIC T5/T4
DIP A21 TA (100…135)°C

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

IP66

IP66

IP66

ISSEP 02 ATEX 043

POCC IT. ГБ05.B02536

No. 07/43-269

EN 60079-0; EN 60079-1; EN 61241-1

ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99

ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002

II 2 G Ex d IIC T5/T4
II 2 D Ex tD A21 T100°C / T135°C

EXECUTION
installation
PROTECTION DEGREE
CERTIFICATE REF.
RULES OF COMPLIANCE

EMERGENCY UNIT
ATEX 94/9/EC

GOST-R (RTR / RTN)

GOST-K

1Ex d IIC T6
DIP A21 TA T85°C

1Ex d IIC T6
DIP A21 TA T85°C

ZONA 1 / 2 - ZONA 21 / 22

ZONA 1 / 2 - ZONA 21 / 22

ZONA 1 / 2 - ZONA 21 / 22

IP66

IP66

IP66

INERIS 08 ATEX 018

POCC IT. ГБ05.B02537

No. 07/43-269

EN 60079-0; EN 60079-1;
EN 61241-0; EN 61241-1;

ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99

ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002

II 2 G Ex d IIC T6
II 2 D Ex d tD A21 T85°C

EXECUTION
installation
PROTECTION DEGREE
CERTIFICATE REF.
RULES OF COMPLIANCE

Mechanical characteristics
Body	

marine grade copper free aluminium (control gear & emergency unit)

Tubes	

high-temperature resistant borosylicate glass tube

painting	

external epoxy powders grey ral-9006 colour

screws	

external stainless steel

gaskets	

nbr rubber

reflectors	

white stove enamelled sheet steel

cable entry	

3/4” npt size threaded

Electrical characteristics
power supply	

elettronic ballast 220v/240v - 50/60hz (p.f.corrected - cos ρ ≥ 0,98)

lampholders	

bi-pin g13 cap

internal wiring	

high-temperature resistant silicon rubber insulation cables

emergency unit	
	

emergency unit composed of inverter charger and ni-cd battery pack 4A/h 6v. autonomy from 60 to 120min. 	
Led power-on indicating lamp provided

On Request Accessories:
•	Pole mounting kit complete with stainless steel hardware
•	Ceiling mounting kit complete with stainless steel hardware
•	Pendant mounting kit complete with stainless steel hardware
•	Wall/Structure mounting kit complete with stainless steel hardware
•	Galvanized steel wire protection guard

•	Stainless steel wire protection guard
•	Stainless steel reflectors
•	External painting colour on request
•	Electronic ballast with voltage supply different than standard
•	Ni-Cd Battery pack 7A/h 6V for Emergency Unit with Autonomy more than 150min

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 1

EVF

Ex Lighting
Ex Lighting

EVF Technical data
TEMPERATURE CLASS
(GAS)

LAMP

EVF

CODE

TEMPERATURE CLASS
(DUSTS)

LAMPHOLDER

CABLE ENTRY

EMERGENCY
UNIT

AUTONOMY

DETAIL

FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 220V/240V - 50/60Hz
	

T5	
T4	

T 100°C 	
T 135°C

G13	

2 x 3/4”	

-	

-	

		
A

	

T5	
T4	

T 100°C 	
T 135°C

G13	

2 x 3/4”	

-	

-	

A

	

T5	
T4	

T 100°C 	
T 135°C 	

G13	

2 x 3/4”	

-	

-	

A

	

T5	
T4	

T 100°C 	
T 135°C	

G13	

2 x 3/4”	

-	

-	

B

	

T5	
T4	

T 100°C 	
T 135°C

G13	

2 x 3/4”	

-	

-	

B

	

T5	
T4	

T 100°C 	
T 135°C

G13	

2 x 3/4”	

-	

-	

B

EVF18EL	
1 x 18W
			
EVF36EL	
1 x 36W
			
EVF58EL	
1 x 58W
			
EVF18BEL	
2 x 18W
			
EVF36BEL	
2 x 36W
			
EVF58BEL	
2 x 58W
			

EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 220V/240V - 50/60Hz
	

T5	
T4	

T 100°C 	
G13	
T 135°C		

1 x 3/4”
	
4.8 V 1 x 1/2”		 4Ah	

2h	

C

	

T5	
T4	

T 100°C	
G13	
T 135°C		

1 x 3/4”
1 x 1/2”	

4.8 V - 4Ah	

2h	

C

	

T5	
T4	

T 100°C 	
G13	
T 135°C		

1 x 3/4”
1 x 1/2”	

4.8 V - 4Ah	

2h	

C

	

T5	
T4	

T 100°C 	
G13	
T 135°C		

1 x 3/4”
1 x 1/2”	

4.8 V - 4Ah	

2h	

D

	

T5	
T4	

T 100°C 	
G13	
T 135°C		

1 x 3/4”
1 x 1/2”	

4.8 V - 4Ah	

2h	

D

	

T5	
T4	

T 100°C 	
G13	
T 135°C		

1 x 3/4”
1 x 1/2”	

4.8 V - 4Ah	

2h	

D

EVF18ELME	 1 x 18W
			
EVF36ELME	 1 x 36W
			
EVF58ELME	 1 x 58W
			
EVF18ELBE	
2 x 18W
			
EVF36ELBE	
2 x 36W
			
EVF58ELBE	 2 x 58W
			

EVF Technical features
A [mm]

B [mm]

C [mm]

D [mm]

WEIGHT [Kg]

CABLE ENTRY

DETAIL

EVF18EL

CODE

1000

96

95

602

4,50

2 x 3/4”

A

EVF36EL

1600

96

95

1202

5,70

2 x 3/4”

A

EVF58EL

1900

96

95

1490

7,00

2 x 3/4”

A

EVF18BEL

1000

200

95

602

9,00

2 x 3/4”

B

EVF36BEL

1600

200

95

1202

12,20

2 x 3/4”

B

EVF58BEL

1900

200

95

1490

14,70

2 x 3/4”

B

Reference details

A

A
D

8MA

C

8MA

B

3/4”

B

A
D
8MA

B

C

8MA

3/4”

Since 1961

2 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
Ex Lighting

EVF Technical features
A [mm]

B [mm]

C [mm]

D [mm]

WEIGHT [Kg]

CABLE ENTRY

DETAIL

1000

222

379

602

10,00

1 x 3/4” / 1 x 1/2”

C

EVF36ELME

1600

222

379

1202

12,00

1 x 3/4” / 1 x 1/2”

C

EVF58ELME

1900

222

379

1490

14,00

1 x 3/4” / 1 x 1/2”

EVF

CODE
EVF18ELME

C

EVF18ELBE

1000

287

265

602

16,00

1 x 3/4” / 1 x 1/2”

D

EVF36ELBE

1600

287

265

1202

19,00

1 x 3/4” / 1 x 1/2”

D

EVF58ELBE

1900

287

265

1490

21,00

1 x 3/4” / 1 x 1/2”

D

Reference details

C

A

B
1 -1/2”

C

D

3/4”

3/4”

D

A

B

3/4”

D

3/4”

C

1 -1/2”

EVF Installation and mounting details

Wall/structure mounting

type 4

108

45

Pole mounting
Assemblig detail with pole (typical)
3/4”

50

273

50

50

100

100

45°

8
12

45°

273

10
0

8
12

type 3

45

45

170

156

type 2

156

type 1

Pendant mounting

170

Ceiling mounting

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 3
Ex Lighting

EVF Polar diagrams – photometric data
EVF

EVF18BEL

EVF36BEL

EVF58BEL

EVF On request accessories
CODE
GABBIAEVFF18	

DESCRIPTION

INSTALLATION

18W SIZE GALVANIZED STEEL WIRE PROTECTION GUARD		

MATERIAL
GALVANIZED STEEL

GABBIAEVFF36	

36W SIZE GALVANIZED STEEL WIRE PROTECTION GUARD		

GALVANIZED STEEL

GABBIAEVFF58	

58W SIZE GALVANIZED STEEL WIRE PROTECTION GUARD		

GALVANIZED STEEL

GABBIAEVFF18IX	

18W SIZE STAINLESS STEEL WIRE PROTECTION GUARD		

STAINLESS STEEL

GABBIAEVFF36IX	

36W SIZE STAINLESS STEEL WIRE PROTECTION GUARD		

STAINLESS STEEL

GABBIAEVFF58IX	

58W SIZE STAINLESS STEEL WIRE PROTECTION GUARD		

STAINLESS STEEL

D18IX	

18W SIZE STAINLESS STEEL REFLECTOR		

STAINLESS STEEL

D36IX	

36W SIZE STAINLESS STEEL REFLECTOR		

STAINLESS STEEL

D58IX	

58W SIZE STAINLESS STEEL REFLECTOR		

20301.0151	

SINGLE LAMP CEILING MOUNTING KIT C/W HARDWARE	

STAINLESS STEEL

TYPE 1	

ALUM. LIGHT ALLOY

20301.0152	

TWIN LAMP CEILING MOUNTING KIT C/W HARDWARE	

TYPE 1	

ALUM. LIGHT ALLOY

20301.0153	

SINGLE LAMP POLE MOUNTING KIT (SIZE 1” DIA.) C/W HARDWARE	

TYPE 4	

GALVANIZED STEEL

20301.0155	

SINGLE LAMP POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE	

TYPE 4	

GALVANIZED STEEL

20301.0156	

TWIN LAMP POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE	

TYPE 4	

GALVANIZED STEEL

20301.0157	

SINGLE LAMP POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE	

TYPE 4	

GALVANIZED STEEL

20301.0158	

TWIN LAMP POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE	

TYPE 4	

GALVANIZED STEEL

20302.0128	

SINGLE LAMP WALL/STRUCTURE MOUNTING KIT C/W HARDWARE	

TYPE 3	

GALVANIZED STEEL

20302.0128	

TWIN LAMP WALL/STRUCTURE MOUNTING KIT C/W HARDWARE	

TYPE 3	

GALVANIZED STEEL

20301.0165	

SINGLE LAMP PENDANT MOUNTING KIT C/W HARDWARE	

TYPE 2	

GALVANIZED STEEL

20301.0165	

TWIN LAMP PENDANT MOUNTING KIT C/W HARDWARE	

TYPE 2	

GALVANIZED STEEL

REMARK:

Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.

Since 1961

4 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
LIGHTING FIXTURES
FOR INCANDESCENT AND
DISCHARGE LAMPS

Explosion Proof Electrical Equipment

EVAC

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D

LIGHTING FIXTURE / CONTROL GEAR
ATEX 94/9/EC

GOST-R (RTR / RTN)

GOST-K

1Ex d IIC T6 (T5…T2) X
DIP A21 TA (80…290)°C

1Ex d IIC T6 (T5…T2) X
DIP A21 TA (80…290)°C

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

IP66

IP66

IP66

INERIS 01 ATEX 0054X

POCC IT. ГБ05.B02536

No. 07/43-269

EN 60079-0; EN 60079-1; EN 61241-1

ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99

ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002

II 2 G Ex d IIC T6/T2
II 2 D Ex tD A21 T80°C / T290°C

EXECUTION
installation
PROTECTION DEGREE
CERTIFICATE REF.
RULES OF COMPLIANCE

Mechanical characteristics
Body	

marine grade copper free aluminium (control gear & lamp body)

Globe	

high-temperature resistant borosylicate glass

painting	

external epoxy powders grey ral-9006 colour

screws	

external stainless steel

gaskets	

silicon rubber

cable entry	

3/4” npt size threaded

Installation swivel bracket	 AISI 316L stainless steel

Electrical characteristics
Power supply (prc)	

conventional ballast 230V - 50Hz (p.f. corrected - cos ρ ≥ 0,95)

Lampholders	

porcelain E27/E40 size

Internal wiring	

high-temperature resistant silicon rubber insulation cables

Terminals	

suitable up to 4mm/sq cables

On Request Accessories:
•Ceiling mounting AISI 316L stainless steel kit complete with stainless steel hardware
•Pendant mounting AISI 316L stainless steel kit complete with stainless steel hardware
•Pole mounting kit 1” – 1 1/2” – 2” dia. complete with stainless steel hardware
•Wall/Structure mounting kit complete with stainless steel hardware
•Galvanized steel wire protection guard
•Stainless steel wire protection guard

•White stove enamelled aluminium reflectors
•Stainless steel reflectors
•External painting colour on request
•Control gear with voltage supply different than standard
•Threaded cable entry different than standard

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 5

EVAC

Ex Lighting
Ex Lighting

EVAC

EVAC Technical data
CODE

TEMPERATURE CLASS
(GAS)

LAMP

TEMPERATURE CLASS
(DUSTS)

LAMPHOLDER
SIZE

CABLE ENTRY SIZE

DETAIL

LIGHTING FIXTURE FOR INCANDESCENT LAMP - POWER SUPPLY 230V-50Hz
EVAC101

100 W

EVAC100

100 W

EVAC201

T4

T 130°C

E-27

1 x 3/4"

A

T4

T 130°C

E-27

2 x 3/4"

B

200 W

T4
T3

T 130°C
T 195°C

E-27

1 x 3/4"

A

EVAC200

200 W

T4
T3

T 130°C
T 195°C

E-27

2 x 3/4"

B

EVAC301

300 W

T4
T3

T 130°C
T 195°C

E-40

1 x 3/4"

A

EVAC300

300 W

T4
T3

T 130°C
T 195°C

E-40

2 x 3/4"

B

EVAC501

500 W

T3

T 195°C

E-40

1 x 3/4"

A

EVAC500

500 W

T3

T 195°C

E-40

2 x 3/4"

B

EVAC100-E20

25 W
20 W

T5
T4

T 95°C
T 130°C

E-14 + Ba-15s

2 x 3/4"

B

1 x 3/4"

A

LIGHTING FIXTURE FOR HALOGEN LAMP - POWER SUPPLY 230V-50Hz
EVAC101-100H

100 W

T4

T 130°C

E-27

EVAC100-100H

100 W

EVAC201-150H

150 W

T4

T 130°C

E-27

2 x 3/4"

B

T1

T 130°C

E-27

1 x 3/4"

A

EVAC200-150H

150 W

T2

T 130°C

E-27

2 x 3/4"

B

250 W

T4
T3

T 130°C
T 195°C

EVAC301-250H

E-27

1 x 3/4"

A

EVAC300-250H

250 W

T4
T3

T 130°C
T 195°C

E-27

2 x 3/4"

B

LIGHTING FIXTURE FOR HIGH PRESSURE MERCURY VAPOUR LAMP - POWER SUPPLY 230V-50Hz
EVAC101-80HG

80 W

T4

T 130°C

E-27

2 x 3/4” / 1 x 1-1/2”

C

EVAC201-125HG

125 W

T3

T 195°C

E-27

2 x 3/4” / 1 x 1-1/2”

C

EVAC301-250HG

250 W

T3

T 195°C

E-40

2 x 3/4” / 1 x 1-1/2”

C

EVAC501-250HG

250 W

T4

T 130°C

E-40

2 x 3/4” / 1 x 1-1/2”

C

EVAC501-400HG

400 W

T3

T 195°C

E-40

2 x 3/4” / 1 x 1-1/2”

C

LIGHTING FIXTURE FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V-50Hz
EVAC101-70HPNA

70 W

T4

T 130°C

E-27

2 x 3/4" / 1 x 1-1/2"

C

EVAC301-150HPNA

150 W

T4

T 130°C

E-40

2 x 3/4" / 1 x 1-1/2"

C

EVAC301-250HPNA

250 W

T3
T2

T 195°C
T 290°C

E-40

2 x 3/4" / 1 x 1-1/2"

C

EVAC501-400HPNA

400 W

T3

T 195°C

E-40

2 x 3/4" / 1 x 1-1/2"

C

LIGHTING FIXTURE FOR METAL HALIDE LAMP - POWER SUPPLY 230V-50Hz
EVAC101-100MH

100 W

T4

T 130°C

E-27

2 x 3/4" / 1 x 1-1/2"

C

EVAC301-150MH

150 W

T4
T3

T 130°C
T 195°C

E-27

2 x 3/4" / 1 x 1-1/2"

C

EVAC301-250MH

250 W

T3

T 195°C

E-40

2 x 3/4" / 1 x 1-1/2"

C

EVAC501-400MH

400 W

T3

T 195°C

E-40

2 x 3/4" / 1 x 1-1/2"

C

LIGHTING FIXTURE FOR BLENDED LIGHT LAMP - POWER SUPPLY 230V-50Hz
EVAC201-160MLL

160 W

T3

T 195°C

E-27

2 x 3/4" / 1 x 1-1/2"

A

EVAC200-160MLL

160 W

T3

T 195°C

E-27

2 x 3/4" / 1 x 1-1/2"

B

EVAC301-250MLL

250 W

T3

T 195°C

E-40

2 x 3/4" / 1 x 1-1/2"

A

EVAC300-250MLL

250 W

T3

T 195°C

E-40

2 x 3/4" / 1 x 1-1/2"

B

Since 1961

6 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
Ex Lighting

EVAC Technical features
CODE

B [mm]

C [mm]

Ø D [mm]

Ø E [mm]

weight [Kg]

CABLE ENTRY

DETAIL

150	

270	

240	

145	

280	

3,50	

1 x 3/4”	

A

EVAC100	

150	

270	

240	

145	

280	

3,50	

2 x 3/4”	

B

EVAC201	

175	

290	

270	

170	

345	

4,00	

1 x 3/4”	

A

EVAC200	

175	

290	

270	

170	

345	

4,00	

2 x 3/4”	

B

EVAC301	

200	

390	

330	

190	

402	

7,00	

1 x 3/4”	

A

EVAC300	

200	

390	

330	

190	

402	

7,00	

2 x 3/4”	

B

EVAC501	

260	

420	

395	

255	

515	

10,00	

1 x 3/4”	

A

EVAC500	

260	

420	

395	

255	

515	

10,00	

2 x 3/4”	

B

Reference details

Reference details

A

B

A
3/4”

A
2X3/4”

B

Ø8
.5

60

60

16

80

C

80
60

C

B

3

200
180

D
E

D
E
CODE

A [mm]

B [mm]

C [mm]

Ø D [mm]

Ø E [mm]

weight [Kg]

CABLE ENTRY

DETAIL

545	

515	

145	

280	

9,00	

2 x 3/4”
	
1 x 1-1/2”

C

2 x 3/4”	
1 x 1-1/2”

C

2 x 3/4”
	
1 x 1-1/2”

C

2 x 3/4”
	
1 x 1-1/2”
	

C

EVAC101-..HG
EVAC101-..HPNA

	 225	

EVAC101-..MH							
	
EVAC201-..HG	
225	
565	
545	
170	
345	
9,50
							
EVAC301-..HG
EVAC301-..HPNA

	 225	

665	

640	

190	

402	

12,00	

EVAC301-..MH							
EVAC501-..HG
EVAC501-..HPNA

	 225	

695	

670	

255	

515	

15,50	

EVAC501-..MH							

Reference details

C

A
1-1/2”

C

B

200

5

30

28 28

0
Ø1

192
D
E
Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 7

EVAC

A [mm]

EVAC101
Ex Lighting

EVAC Installation and mounting details

237

16

type 1

Pendant mounting

type 2
275

180
54

EVAC

Ceiling mounting

Wall/structure mounting

type 3

283

58

Since 1961

8 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
Ex Lighting

EVAC Installation and mounting details
EVAC

Pole mounting / Assemblig detail with pole (typical)

SEALING
FITTINGS

SEALING
FITTINGS

POLE

POLE

25°

25°

EVAC Polar diagrams – photometric data
EVAC125HG

EVAC150HPS

EVAC100MH

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 9
Ex Lighting

EVAC Polar diagrams – photometric data
EVAC400HPS-D

EVAC400MH-D

EVAC

EVAC250HG-D

EVAC On request accessories
CODE
20302.0070	

DESCRIPTION

INSTALLATION

EVAC 100 / 101 SIZE STANDARD REFLECTOR		

MATERIAL
WHITE STOVE ENAMELLED ALUMININIUM

20302.0071	

EVAC 200 / 201 SIZE STANDARD REFLECTOR		

WHITE STOVE ENAMELLED ALUMININIUM

20302.0072	

EVAC 300 / 301 SIZE STANDARD REFLECTOR		

WHITE STOVE ENAMELLED ALUMININIUM

20302.0073	

EVAC 500 / 501 SIZE STANDARD REFLECTOR		

WHITE STOVE ENAMELLED ALUMININIUM

20302.0025	

EVAC 100 / 101 SIZE STAINLESS STEEL REFLECTOR		

STAINLESS STEEL

20302.0026	

EVAC 200 / 201 SIZE STAINLESS STEEL REFLECTOR		

STAINLESS STEEL

20302.0027	

EVAC 300 / 301 SIZE STAINLESS STEEL REFLECTOR		

STAINLESS STEEL

20302.0028	

EVAC 500 / 501 SIZE STAINLESS STEEL REFLECTOR		

STAINLESS STEEL

20302.0074	

EVAC 100 / 101 SIZE STANDARD PROTECTION GUARD		

GALVANIZED STEEL

20302.0075	

EVAC 200 / 201 SIZE STANDARD PROTECTION GUARD		

GALVANIZED STEEL

20302.0076	

EVAC 300 / 301 SIZE STANDARD PROTECTION GUARD		

GALVANIZED STEEL

20302.0077	

EVAC 500 / 501 SIZE STANDARD PROTECTION GUARD		

GALVANIZED STEEL

20302.0037	

EVAC 100 / 101 SIZE STAINLESS STEEL PROTECTION GUARD		

STAINLESS STEEL

20302.0038	

EVAC 200 / 201 SIZE STAINLESS STEEL PROTECTION GUARD		

STAINLESS STEEL

20302.0039	

EVAC 300 / 301 SIZE STAINLESS STEEL PROTECTION GUARD		

STAINLESS STEEL

20302.0040	 EVAC 500 / 501 SIZE STAINLESS STEEL PROTECTION GUARD		

STAINLESS STEEL

20302.0078	

CEILING MOUNTING KIT C/W HARDWARE	

TYPE 1	

AISI 316L STAINLESS STEEL

20302.0079	

WALL/STRUCTURE MOUNTING KIT C/W HARDWARE	

TYPE 3	

AISI 316L STAINLESS STEEL

20302.0082	

PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS	

TYPE 2	

AISI 316L STAINLESS STEEL

REMARK:

Due to the development of the national and international specifications and of the technology, the above technical characteristics showed
on this bulletin can be considered as binding on our confirmation only.

Since 1961

10 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
LIGHTING FIXTURES
FOR FLUORESCENT LAMPS

Explosion Proof Electrical Equipment

EVAC-FL

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D

LIGHTING FIXTURE / CONTROL GEAR
ATEX 94/9/EC

GOST-R (RTR / RTN)

GOST-K

1Ex d IIC T6 X
DIP A21 TA (80)°C

1Ex d IIC T6 X
DIP A21 TA (80)°C

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

IP66

IP66

IP66

INERIS 01 ATEX 0054X

POCC IT. ГБ05.B02536

No. 07/43-269

EN 60079-0; EN 60079-1; EN 61241-1

ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99

ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002

II 2 G Ex d IIC T6/T2
II 2 D Ex tD A21 T80°C / T290°C

EXECUTION
installation
PROTECTION DEGREE
CERTIFICATE REF.
RULES OF COMPLIANCE

Mechanical characteristics
Body	

marine grade copper free aluminium (control gear & lamp body)

globe	

high-temperature resistant borosylicate glass

painting	

external epoxy powders grey ral-9006 colour

screws	

external stainless steel

gaskets	

silicon rubber

cable entry	

3/4” npt size threaded

Installation swivel bracket	

AISI 316L stainless steel

Electrical characteristics
Power supply (prc)	

elettronic ballast 220V/240V - 50/60Hz (p.f.corrected - cos ρ ≥ 0,98)

lampholders	

porcelain e27 size - plastic 2g10 size

internal wiring	

high-temperature resistant silicon rubber insulation cables

terminals	

suitable up to 4mm/sq cables

On Request Accessories:
•Ceiling mounting AISI 316L stainless steel kit complete with stainless steel hardware
•Pendant mounting AISI 316L stainless steel kit complete with stainless steel hardware
•Pole mounting kit 1” – 1 1/2” – 2” dia. complete with stainless steel hardware
•Wall/Structure mounting kit complete with stainless steel hardware
•Galvanized steel wire protection guard
•Threaded cable entry different than standard

•Stainless steel wire protection guard
•White stove enamelled aluminium reflectors
•Stainless steel reflectors
•External painting colour on request
•Electronic ballast with voltage supply different than standard

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 11

EVAC-FL

Ex Lighting
Ex Lighting

EVAC-FL

EVAC-FL Technical data
CODE

TEMPERATURE CLASS
(GAS)

LAMP

TEMPERATURE CLASS
(DUSTS)

LAMPHOLDER
SIZE

CABLE ENTRY
SIZE

DETAIL

LIGHTING FIXTURES FOR FLUORESCENT LAMPS - POWER SUPPLY 220V/240V - 50/60Hz
EVAC101-15FL	

1 x 15W 	

T6	

T 80°C	

E-27	

1 x 3/4”	

A

EVAC100-15FL	

1 x 15W 	

T6	

T 80°C	

E-27	

2 x 3/4”	

B

EVAC201-23FL	

1 x 23W 	

T6	

T 80°C	

E-27	

1 x 3/4”	

A

EVAC301-218FL	

2 x 18W 	

T6	

T 80°C	

2G-10	

2 x 3/4”	

C

EVAC301-318FL	

3 x 18W 	

T6	

T 80°C	

2G-10	

2 x 3/4”	

C

EVAC501-236FL	

2 x 36W 	

T6	

T 80°C	

2G-10	

2 x 3/4”	

C

EVAC501-336FL	

3 x 36W 	

T6	

T 80°C	

2G-10	

2 x 3/4”	

C

EVAC-FL Technical features
CODE

A [mm]

B [mm]

C [mm]

Ø D [mm]

Ø E [mm]

EVAC101-15FL	

150	

270	

235	

145	

280	

weight [Kg] CABLE ENTRY
3,5	

DETAIL

1 x 3/4”	

A

150	

270	

235	

145	

280	

3,5	

4 x 3/4”	

B

175	

270	

255	

170	

345	

4	

1 x 3/4”	

A

EVAC301-218FL	

225	

180
605	

590	

190	

395	

12	

2 x 3/4”	

EVAC301-318FL	

225	

605	

590	

190	

395	

12	

2 x 3/4”	

C

EVAC501-236FL	

225	

648	

620	

255	

515	

15,5	

2 x 3/4”	

C

EVAC501-336FL	

225	

620	

255	

515	

15,5	

2 x 3/4”	

80

A

.5

C

∅8

60

80

Reference details

B

A
3/4”

180

C

3

60

60

200

80

60

16

.5

60

∅8

648	
60

16

Reference details

200

3

80

EVAC100-15FL	
EVAC201-23FL	

A
2X3/4”

B

Ø8
.5

60

0

28

D
E

60

16

80

192

28

Ø1

C

80
60

C

B

3

200
180

Reference details

D
E

30

C

A
1-1/2”
200

5

C

B

200

5

30

28 28

0
Ø1

192
D
E

Since 1961

12 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
Ex Lighting

EVAC-FL Installation and mounting details
EVAC-FL

Ceiling mounting

237

16

type 1

Pendant mounting

275

type 2

54

180

Wall/structure mounting

type 3

283

58

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 13
Ex Lighting

EVAC-FL

EVAC-FL Installation and mounting details
Pole mounting

SEALING
FITTINGS

SEALING
FITTINGS

POLE

POLE

25°

25°

EVAC-FL On request accessories
CODE

DESCRIPTION

INSTALLATION

MATERIAL

20302.0070	

EVAC 100 / 101 SIZE STANDARD REFLECTOR		

WHITE STOVE ENAMELLED ALUM.

20302.0071	

EVAC 200 / 201 SIZE STANDARD REFLECTOR		

WHITE STOVE ENAMELLED ALUM.

20302.0072	

EVAC 300 / 301 SIZE STANDARD REFLECTOR		

WHITE STOVE ENAMELLED ALUM.

20302.0073	

EVAC 500 / 501 SIZE STANDARD REFLECTOR		

WHITE STOVE ENAMELLED ALUM.

20302.0025	

EVAC 100 / 101 SIZE STAINLESS STEEL REFLECTOR		

STAINLESS STEEL

20302.0026	

EVAC 200 / 201 SIZE STAINLESS STEEL REFLECTOR		

STAINLESS STEEL

20302.0027	

EVAC 300 / 301 SIZE STAINLESS STEEL REFLECTOR		

STAINLESS STEEL

20302.0028	

EVAC 500 / 501 SIZE STAINLESS STEEL REFLECTOR		

STAINLESS STEEL

20302.0074	

EVAC 100 / 101 SIZE STANDARD PROTECTION GUARD		

GALVANIZED STEEL

20302.0075	

EVAC 200 / 201 SIZE STANDARD PROTECTION GUARD		

GALVANIZED STEEL

20302.0076	

EVAC 300 / 301 SIZE STANDARD PROTECTION GUARD		

GALVANIZED STEEL

20302.0077	

EVAC 500 / 501 SIZE STANDARD PROTECTION GUARD		

GALVANIZED STEEL

20302.0037	

EVAC 100 / 101 SIZE STAINLESS STEEL PROTECTION GUARD		

STAINLESS STEEL

20302.0038	

EVAC 200 / 201 SIZE STAINLESS STEEL PROTECTION GUARD		

STAINLESS STEEL

20302.0039	

EVAC 300 / 301 SIZE STAINLESS STEEL PROTECTION GUARD		

STAINLESS STEEL

20302.0040	 EVAC 500 / 501 SIZE STAINLESS STEEL PROTECTION GUARD		
20302.0078	

CEILING MOUNTING KIT C/W HARDWARE	

20302.0079	

WALL/STRUCTURE MOUNTING KIT C/W HARDWARE	

20302.0082	

PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS	

TYPE 1	
TYPE 3	
TYPE 2	

STAINLESS STEEL
AISI 316L STAINLESS STEEL
AISI 316L STAINLESS STEEL
AISI 316L STAINLESS STEEL

REMARK:

Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.
Since 1961

14 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
PORTABLE LIGHTING FIXTURES
FOR INCANDESCENT LAMPS

Explosion Proof Electrical Equipment

EVP-100

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts)
Classification: Group II - Category 2G 2D

LIGHTING FIXTURE
ATEX 94/9/EC

GOST-R (RTR / RTN)

GOST-K

1Ex d IIC T4 (T5…T2) X
DIP A21 TA (130)°C

1Ex d IIC T4 (T5…T2) X
DIP A21 TA (130)°C

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

IP66

IP66

IP66

INERIS 01 ATEX 0054X

POCC IT. ГБ05.B02536

No. 07/43-269

EN 60079-0; EN 60079-1;
EN 61241-1

ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99

ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002

II 2 G Ex d IIC T4/T2
II 2 D Ex tD A21 T130°C

EXECUTION
installation
PROTECTION DEGREE
CERTIFICATE REF.
RULES OF COMPLIANCE

Mechanical characteristics
Body	

marine grade copper free aluminium (control gear & lamp body)

Globe	

high-temperature resistant borosylicate glass

Painting	

external epoxy powders grey ral-9006 colour

Screws	

external stainless steel

Gaskets	

silicon rubber

Cable entry	

Nickel plated brass cable gland 1/2” npt (armoured cable)

Electrical characteristics
Power supply 	

12 ÷ 230V AC/DC

lampholders	

e27 porcelain

On Request Accessories:
• External painting colour on request

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 15

EVP-100

Ex Lighting
Ex Lighting

EVP-100

EVP-100 Technical data
CODE

LAMP

TEMPERATURE CLASS
(GAS)

TEMPERATURE CLASS
(DUSTS)

LAMPHOLDER
SIZE

CABLE
ENTRY SIZE

DETAIL

LIGHTING FIXTURE FOR INCANDESCENT LAMP - POWER SUPPLY 230V-50Hz
EVP-100	

100 W 	

T4	

T 130°C	

E-27	

CABLE GLAND 1/2” NPT	

A

EVP-100 Technical features
CODE

A [mm]

B [mm]

C [mm]

Ø D [mm]

weight [Kg]

CABLE ENTRY

DETAIL

395	

257	

287	

150	

4,00	

CABLE GLAND 1/2” NPT	

A

EVP-100	

Reference details

B

A

A

ØD
C

REMARK:

Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.

Since 1961

16 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
AIRCRAFT WARNING LIGHTS
AND A.W.L. CONTROL PANELS

Explosion Proof Electrical Equipment

AWL

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D

OBSTRUCTION LIGHTING FIXTURE
ATEX 94/9/EC

GOST-R (RTR / RTN)

GOST-K

1Ex d IIC T6 (T5…T2) X
DIP A21 TA (80…290)°C

1Ex d IIC T6 (T5…T2) X
DIP A21 TA (80…290)°C

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

IP66

IP66

IP66

INERIS 01 ATEX 0054X

POCC IT. ГБ05.B02536

No. 07/43-269

EN 60079-0; EN 60079-1; EN 61241-1

ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99

ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002

ATEX 94/9/EC

GOST-R (RTR / RTN)

GOST-K

1Ex d IIB+H2 T6…T3
DIP A21 TA 85°C ÷ 150°C
1Ex d IIC T6 (T5…T2) X
DIP A21 TA (80…290)°C

1Ex d IIB+H2 T6…T3
DIP A21 TA 85°C ÷ 150°C
1Ex d IIC T6 (T5…T2) X
DIP A21 TA (80…290)°C

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

IP66

IP66

IP66

II 2 G Ex d IIC T6/T2
II 2 D Ex tD A21 T80°C / T290°C

EXECUTION
installation
PROTECTION DEGREE
CERTIFICATE REF.
RULES OF COMPLIANCE

CONTROL PANEL
II 2 G Ex d IIB+H2 T6...T3
II 2 D Ex tD A21 T85°C ÷ T150°C
II 2 G Ex d IIC T6/T2
II 2 D Ex tD A21 T80°C / T290°C

EXECUTION
PROTECTION DEGREE
PROTEZIONE MECCANICA
ICAO

in according to icao directive ANNEX 14
EN 60079-0; EN 60079-1;
EN 60079-11; EN 61241-0;
EN 61241-1

RULES OF COMPLIANCE

ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99

ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002

Mechanical characteristics
Body	

marine grade copper free aluminium

globe	

high-temperature resistant borosylicate glass

fresnel len	

shock proof acrilyc material suitable for high temperatures

painting	

external epoxy powders grey ral-9006 colour

screws	

external stainless steel

gaskets	

silicon rubber

cable entry	

3/4” npt size threaded

Electrical characteristics
Lampholders	

porcelain e27 size

internal wiring	

high-temperature resistant silicon rubber insulation cables

terminals	

suitable up to 4mm/sq cables

medium intensity	

flashing obstruction light 1450 / 2000 cd intensity (over than 45mt distance)

low intensity	

steady obstruction light 30 cd intensity (less than 45mt distance)

construction	

single awl - twin awl (1 main + 1 spare) in according to icao directive

On Request Accessories:
• Galvanized steel wire protection guard
• External painting colour on request
• Stainless steel wire protection guard
• Threaded cable entry different than standard
• Aircraft Warning Lights and control panel support manufactured in according to customer specification
Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 17

AWL

Ex Lighting
Ex Lighting

AWL Technical data
AWL

CODE

LAMP TYPE

TEMPERATURE
CLASS
(GAS)

TEMPERATURE
CLASS
(DUSTS)

FLASHING
[x/min.]

LAMPHOLDER

CABLE
ENTRY
SIZE

DETAIL

EVAC201-F	

100W INCANDESCENT	

T4	

T 130°C	

-	

E-27	

1 x 3/4”	

A

EVAC200-F	

100W INCANDESCENT	

T4	

T 130°C	

-	

E-27	

4 x 3/4”	

A

EVAC201-XF	

6J XENOFLASH	

T6	

T 80°C	

65 ± 10	

E-27	

1 x 3/4”	

C

EVAC200-XF	

6J XENOFLASH	

T6	

T 80°C	

65 ± 10	

E-27	

4 x 3/4”	

C

EVAC201-XFR-24V	

6J XENOFLASH	

T6	

T 80°C	

65 ± 10	

E-27	

1 x 3/4”	

C

EVAC201-F2R	

2 x 100W INCAND.	

T4	

T 130°C	

-	

E-27	

1 x 3/4”	

B

EVAC201-XF2R	

2 x 6J XENOFLASH	

T6	

T 80°C	

65 ± 10	

E-27	

1 x 3/4”	

D

EVAC301-25R	

40W INCANDESCENT	

T4	

T 130°C	

-	

E-27	

1 x 3/4”	

C

EVAC300-25R	

40W INCANDESCENT	

T4	

T 130°C	

-	

E-27	

4 x 3/4”	

C

AWL Technical features
CODE
EVAC201-F	

A [mm]

B [mm]

Ø C [mm]

D [mm]

WEIGHT [Kg]

CABLE ENTRY

DETAIL

415	

200	

-	

4,50	

1 x 3/4”	

A

430	

EVAC200-F	

430	

415	

200	

-	

4,50	

4 x 3/4”	

A

EVAC201-XF	

280	

260	

176	

-	

4,50	

1 x 3/4”	

C

EVAC200-XF	

280	

260	

176	

-	

4,00	

4 x 3/4”	

C

EVAC201-XFR-24V	

280	

260	

176	

-	

4,00	

1 x 3/4”	

C

EVAC201-F2R	

790	

415	

200	

475	

9,00	

1 x 3/4”	

B

EVAC201-XF2R	

630	

260	

176	

453	

8,00	

1 x 3/4”	

D

EVAC301-25R	

345	

322	

197	

-	

7,00	

1 x 3/4”	

C

EVAC300-25R	

345	

322	

197	

-	

7,00	

4 x 3/4”	

C

Reference details

A

B

D
ØC

ØC

A

A

B

B

ØC

180
200

Since 1961

18 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
Ex Lighting

AWL Technical features
Reference details

D

AWL

C

D
ØC

ØC

A

A

B

B

ØC

180
200

Aircraft warning lights models
FRESNEL

ROTALLARM

XENOFLASH

MULTI-LED

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 19
Ex Lighting

AWL

AWL Control panels
ex d
INSTRUMENT
HOUSING WITH
PHOTOELECTRIC CELL

>>

01

BREATHER
VALVE
TYPE ecd

02

03
AUT.

ON

MAN.

OFF

04

05

ON
OFF

12

07

06

ON
OFF

ON

13

08

15

10

ON

OFF

OFF

14

09

ON

ON

OFF

OFF

16

11

ON

ON

OFF

17

OFF

18

19

Weatherproof Ip66
INSTRUMENT
HOUSING WITH
PHOTOELECTRIC CELL

>>

BREATHER
VALVE
TYPE ecde

02

01

03
AUT.

ON

MAN.

OFF

04

05

06

07

EVAC On request accessories
CODE

DESCRIPTION

MATERIAL

20302.0075	

EVAC 200 / 201 SIZE STANDARD PROTECTION GUARD	

GALVANIZED STEEL

20302.0076	

EVAC 300 / 301 SIZE STANDARD PROTECTION GUARD	

GALVANIZED STEEL

20302.0038	

EVAC 200 / 201 SIZE STAINLESS STEEL PROTECTION GUARD	

STAINLESS STEEL

20302.0039	

EVAC 300 / 301 SIZE STAINLESS STEEL PROTECTION GUARD	

STAINLESS STEEL

20302.0078	

STRUCTURE MOUNTING KIT C/W HARDWARE	

1030.00055	

RED FRESNEL LEN Ø155mm	

PLASTIC

1030.00186	

ORANGE FRESNEL LEN Ø155mm	

PLASTIC

1030.00211	

GREEN FRESNEL LEN Ø155mm	

PLASTIC

1030.00213	

WHITE FRESNEL LEN Ø155mm	

PLASTIC

AISI 316L STAINLESS STEEL

REMARK:

Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.

Since 1961

20 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
MEdium intensity and loW
intensity MULTILED System
AIRCRAFT warning lights

Ex Lighting

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) - Safe area
Classification: Group II - Category 2G 2D

MIOL - LIOL

OBSTRUCTION WARNING LIGHTS
ATEX 94/9/EC
EXECUTION
INSTALLATION
PROTECTION DEGREE
CERTIFICATE REF.
RULES OF COMPLIANCE
INTERNATIONAL
REGULATIONS
COMPLIANCY FOR
VISUAL AIDS

GOST-R (RTR / RTN)

ZONE 1 / 2 - ZONE 21 / 22
safe area

1Ex d IIC T6 (T5…T2) X
DIP A21 TA (80…290)°C

ZONE 1 / 2 - ZONE 21 / 22
safe area

II 2 G Ex d IIC T6/T2
II 2 D Ex tD A21 T80°C / T290°C

GOST-K

1Ex d IIC T6 (T5…T2) X
DIP A21 TA (80…290)°C

ZONE 1 / 2 - ZONE 21 / 22
safe area

IP66

IP66

IP66

INERIS 01 ATEX 0054X

POCC IT. ГБ05.B02536

No. 07/43-269

EN 60079-0; EN 60079-1;
EN 61241-1

ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99

ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002

ICAO International Standards and Recommended Practices:
Aerodromes - Annex 14 - Volume 1 - 4th Edition (November 2004)
Charapter 6 : Medium Intensity Type B Flashing obstacle light MIOL-B
Charapter 6 : Low Intensity Type A-B Steady burning obstacle light LIOL-A / LIOL-B
FAA Advisor Circular AC150/5345-43F E.B.#67 - Lamp type MIOL-B / LIOL-A / LIOL-B

Mechanical characteristics
Body

Painting

Marine grade copper free aluminium
High-temperature resistant borosylicate glass (zone 1/2 - 21/22 version)
Transparent polycarbonate u/v resistant (safe area version)
External epoxy powders grey ral-9006 colour

Screws

External stainless steel

Gaskets

Silicon rubber

Cable Entry

3/4" Npt size threaded

Globe

Electrical characteristics
Leds

separate groups with individual led protection system - led technology stalilized by constant current generator

Consumption

LIOL-B = 4,8w (single and dual) / miol-B = 30w (single) - 60w (dual)

Medium intensity (MIOL)

flashing light with intensity 2000 cd (+/-25%) flashing 40 flash/minute

Low intensity (LIOL)

steady burning with intensity 32 cd (flashing on request)

Realization

single group leds system with own reflector dual groups leds system, each group with own reflector
(1 main + 1 reserve)

Optical characteristics
Horizontal beam radiation

360° (miol / liol)

Vertical beam radiation

liol = between 5° and 10° / miol = 3°

Efficency

> 91% - pfc factor 0,99

Expetancy life

long life time - more than 10 years

Apply to:
Flare - Airport - Stacks - High buildings - Chimneys - Tower crane - Pipelines - Bridges - Radio and Television towers
Transmission lines - Wind turbines - Radar - and so on

On request accessories:
•Stainless steel wire protection guard
•Aircraft Warning Lights and control panel support manufactured in according to customer specification

•External painting colour on request
•Threaded cable entry different than standard
•Control panel with simultaneous or catenary multilight flashing system

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 21

MIOL - LIOL

Explosion Proof Electrical Equipment
MIOL - LIOL

Ex Lighting

MIOL - LIOL Technical data
LED LAMP
GROUP

CODE

VISUAL AIDS
TYPES

FLASHING
[x/min.]

EXECUTION

TEMPERATURE TEMPERATURE
CLASS (GAS) CLASS (DUSTS)

CABLE
ENTRIES

DETAIL

1 x 3/4"

B

Low Intensity Obstruction warning lights
LIOL-A-S

> 10 cd x 1

LIOL-A-D

RED FIXED

> 10 cd x 2

LIOL-B-S

RED FIXED

> 32 cd x 1

LIOL-B-D

RED FIXED

> 32 cd x 2

RED FIXED

Ex-d

-

T6

T80°C

IP66

-

-

-

2 x 3/4"

D

Ex-d

T6

T80°C

1 x 3/4"

B

IP66

-

-

-

2 x 3/4"

D

Ex-d

T6

T80°C

1 x 3/4"

B

IP66

-

2 x 3/4"

D

T6

T80°C

1 x 3/4"

B

IP66

-

-

Ex-d

-

-

2 x 3/4"

D

MEDIUM Intensity Obstruction warning lights
MIOL-A-S

= 20.000 cd x 1

WHITE
FLASHING

40

IP66

-

-

2 x 3/4"

C

MIOL-A-D

= 20.000 cd x 2

WHITE
FLASHING

40

IP66

-

-

2 x 3/4"

C

MIOL-B-S

= 2.000 cd x 1

RED
FLASHING

40

Ex-d

T6

T80°C

1 x 3/4"

A

RED
FLASHING

= 2.000 cd x 2

MIOL-B-D

= 2.000 cd x 1

MIOL-C-S
MIOL-C-D

RED FIXED

= 2.000 cd x 2

RED FIXED

IP66

40

-

-

2 x 3/4"

C

Ex-d

T6

T80°C

1 x 3/4"

A

IP66

-

-

-

2 x 3/4"

C

Ex-d

T6

T80°C

1 x 3/4"

A

IP66

-

2 x 3/4"

C

T6

T80°C

1 x 3/4"

A

IP66

-

-

Ex-d

-

-

2 x 3/4"

C

MIOL - LIOL Technical features

MIOL

Reference details

MIOL

A

MIOL

260

LIOL

Reference details

B

LIOL

LIOL

T
DO NO

S
SOTT O TE
E

IR

310
315
(FIXING)

DO
NO NOT
N

N

O

D
SE
GI NE
ER IO
EN ENS
T

NE

RG

DO
NO NOT
N

IO

W H IL E E N E
ED

NON

AP

R

S
N
SOTT O TE

E
IR

ED

NON

AP

R

151
(FIXING)

768

O

RG
W H IL E E N E

EN

W
SO HIL
TT E
O

EN
OP RIRE
AP
W
SO HIL
TT E
O

D
SE
GI NE
ER IO
EN ENS
T

T
DO NO

EN

P

EN
OP RIRE
AP

IS

NE

P

IS

IO

445

150

115,5

(FIXING)

135,5
270
275

(FIXING)

Since 1961

22 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
MIOL
Reference details

C

MIOL

LIOL
MIOL - LIOL Technical features
Reference details

D

MIOL

150

240

MIOL

LIOL

LIOL

LIOL

660

200

410

191

320

400

MIOL - LIOL Main rules for aircraft warning lights
MAIN RULES FOR VISUAL AIDS			

ICAO Annex 14 - Aerodromes Vol. 1 - Chapter 6 / 10 (July 2004)			
• The marking and/or lighting of obstacles is intended to reduce hazards to aircraft by indicating the presence of the obstacles
(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.1)
• Marking (red-orange/white painting) is used for day time
• Marking may be ommitted when the obstacle is lighted
• A fixed obstacle above a horizontal surface should be marked and, if the aerodrome is used at night, lighted..
(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.1.4)
• A system of preventive maintenance of visual aids shall be employed to ensure lighting and marking system reliability
(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 10.4.2)
• The reliability of installed lighting equipments shold not less than one year	
(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 10.4.6)	
• The number and arrangement of Low, Medium or High Intensity Obstacle Lights , at each level to be marked, shall be such that the object
is indicated from every angle in azimuth	
• Where a light is shielded in any direction by another, additional light shall be provided	
(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.22)	
• The number of lights needed for each level depends on the outside diameter of the obstacle
• The top lights should be placed sufficiently below the top, so as to minimize contamination by smoke, powders, and so on..	
(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.12)

AWL TYPES (Aircraft Warning Lights)		
LIOL-A / B Low Intensity Obstacle Lights on fixed objects, Type-A / Type-B, shall be steady burning RED lights
(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.23)	
	
MIOL-A	 Medium Intensity Obstacle Lights on fixed objects, Type-A , shall be flashing WHITE lights		
MIOL-B	 Medium Intensity Obstacle Lights on fixed objects, Type-B , shall be flashing RED lights		
MIOL-C	 Medium Intensity Obstacle Lights on fixed objects, Type-C , shall be steady burning RED lights
(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.30)	
MIOL-A / MIOL-B	 Medium Intensity Obstacle Lights Type-A / Type-B, located on an obstacle, shall be flash simultaneously	
(ICA: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.32)	
			
HIOL-A / B High Intensity Obstacle Lights on fixed objects, Type-A / Type-B, shall be flashing WHITE lights
(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.33)	
HIOL-A High Intensity Obstacle Lights Type-A, located on an obstacle, shall be flash simultaneously	
(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.35)	
HIOL-B High Intensity Obstacle Lights Type-B, indicating the presence of tower supporting overhead wires, an others.. shall be flash sequentially	
(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.36)				
Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 23

MIOL - LIOL

Ex Lighting
MIOL - LIOL

Ex Lighting

MIOL - LIOL Indicative diagram to obstruction light selection
OBSTACLE ELEVATION
> 45 m

NO

NO

MARKED
STRUCTURE (1)

YES
MARKED
STRUCTURE (1)

LIOL-A
LIOL-B

EXTENDED

YES
> 150 m

VERTICAL

STRUCTURE
TYPE

YES

MIOL-B + LIOL-B
MIOL-C

NO
YES
LEGEND
(1)

DUAL MIOL-A/B

MIOL-A

DUAL MIOL-A/C

DAY: HIOL-A
+ NIGHT: MIOL-B

DAY: HIOL-A
NIGHT: HIOL-A

DAY: HIOL-A
+ NIGHT: MIOL-C

DAY: MIOL-A
+ NIGHT: MIOL-B

DAY: MIOL-A
NIGHT: MIOL-A

DAY: MIOL-A
+ NIGHT: MIOL-C

Medium intensity obstruction light - TYPE A

MIOL-B
DUAL HIOL-A/C

Low intensity obstruction light - TYPE B

MIOL-A

HIOL-A

Low intensity obstruction light - TYPE A

LIOL-B

DUAL HIOL-A/B

painted obstacle in acc. to icao directive

LIOL-A

NO

Medium intensity obstruction light - TYPE B

MIOL-C

Medium intensity obstruction light - TYPE C

HIOL-A

High intensity obstruction light - TYPE A

HIOL-B

High intensity obstruction light - TYPE B

MIOL - LIOL Polar diagrams – photometric data
LIOL 32cd - Polar

LIOL 32cd - CARTESIAN

Flux 76.52 Im
Maximum 69.78 cd
Position H=-35.00 V=5.00
Efficiency: 100.00%

MIOL 2000cd - Polar

Flux 76.52 Im
Maximum 69.78 cd
Position H=-35.00 V=5.00
Efficiency: 100.00%

Flux 1864.58 Im
Maximum 4301.23 cd
Position H=80.00 V=-90.00
Efficiency: 100.00%

asymmetric VH

asymmetric VH

Flux 1864.58 Im
Maximum 4301.23 cd
Position H=80.00 V=-90.00
Efficiency: 100.00%

asymmetric VH

VH Planes

VH Planes

MIOL 2000cd - Cartesian

VH Planes

asymmetric VH
VH Planes

H Angles

H Angles

MIOL - LIOL On request accessories
CODE

DESCRIPTION

MATERIAL

20302.0074	

EVAC 100 / 101 SIZE STANDARD PROTECTION GUARD	

GALVANIZED STEEL

20302.0077	

EVAC 500 / 501 SIZE STANDARD PROTECTION GUARD	

GALVANIZED STEEL

20302.0037	

EVAC 100 / 101 SIZE STAINLESS STEEL PROTECTION GUARD	

STAINLESS STEEL

20302.0040	

EVAC 500 / 501 SIZE STAINLESS STEEL PROTECTION GUARD	

STAINLESS STEEL

	

CONTROL PANEL WITH SIMULTANEOUS OR CATENARY MULTILIGHT FLASHING SYSTEM	

ALUMINIUM / PAINTED STEEL

REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics

showed on this bulletin can be considered as binding on our confirmation only.

Since 1961

24 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
FLOODLIGHTS FOR HALOGEN AND
DISCHARGE LAMPS

Explosion Proof Electrical Equipment

SFDE

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D

FLOODLIGHT / PROJECTOR
ATEX 94/9/EC
EXECUTION
INSTALLATION

GOST-K

1Ex de IIB T6 (T3…T2)
DIP A21 TA (200…230) °C

1Ex de IIB T6 (T3…T2)
DIP A21 TA (200…230) °C

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

PROTECTION DEGREE

ZONE 1 / 2 - ZONE 21 / 22

IP66

IP66

IP66

INERIS 01 ATEX 0018

POCC IT. ГБ05.B02536

No. 07/43-269

EN 60079-0; EN 60079-1; EN 61241-1

ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99

ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002

CERTIFICATE REF.
RULES OF COMPLIANCE

GOST-R (RTR / RTN)

II 2 G Ex d / Ex de IIB T3/T2
II 2 D Ex tD A21 T200°C / T229°C

Mechanical characteristics
Body	

marine grade copper free aluminium

Diffuser	

tempered front glass

support	

adjustable type hot dip galvanized steel

reflector	

internal polished aluminium

painting	

external epoxy powders grey ral-9006 colour

screws	

external stainless steel

gaskets	

silicon rubber

cable entry	

3/4” npt size threaded

Electrical characteristics
Power supply 	

conventional ballast 230v - 50hz (p.f.corrected - cos ρ ≥ 0,95)

lampholders	

porcelain e40 size

internal wiring	

high-temperature resistant silicon rubber insulation cables

terminals	

suitable up to 4mm/sq cables

On Request Accessories:
• External painting colour on request
• Control gear with voltage supply different than standard
• Threaded cable entry different than standard

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 25

SFDE

Ex Lighting
Ex Lighting

SFDE Technical data
POWER
LAMP

SFDE

CODE

TEMPERATURE CLASS
(GAS)

TEMPERATURE CLASS
(DUSTS)

LAMPHOLDER
SIZE

CABLE ENTRY
SIZE

DETAIL

2 x ISO-M20	

A

FLOODLIGHTS FOR HALOGEN LAMP - POWER SUPPLY 230V-50Hz
SFDE500IA	

500 W 	

T2 	

T 229°C	

E-40	

FLOODLIGHTS FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V-50Hz
SFDE150HPNA	

150 W	

T4 	

T 200°C	

E-40	

2 x ISO-M20	

A

SFDE250HPNA	

250 W 	

T4 	

T 200°C	

E-40	

2 x ISO-M20	

A

SFDE400HPNA	

400 W	

T3 	

T 200°C

E-40	

2 x ISO-M20	

A

	

FLOODLIGHTS FOR METAL HALIDE LAMP - POWER SUPPLY 230V-50Hz
SFDE250MH	

250 W	

T4

SFDE400MH	

400 W	

T3 	

	

T 200°C 	

E-40	

2 x ISO-M20	

A

T 200°C 	

E-40	

2 x ISO-M20	

A

SFDE Technical features
CODE

A [mm]

B [mm]

C [mm]

D [mm]

E [mm]

SFDE150HPNA	

485	

425	

290	

270	

504	

F [mm]
88	

WEIGHT [Kg] CABLE ENTRY
25,00	

2 x ISO-M20	

DETAIL
A

SFDE250HPNA	

485	

425	

290	

270	

504	

88	

25,00	

2 x ISO-M20	

A

SFDE400HPNA	

485	

425	

290	

270	

504	

88	

25,00	

2 x ISO-M20	

A

SFDE250MH	

485	

425	

290	

270	

504	

88	

25,00	

2 x ISO-M20	

A

SFDE400MH	

485	

425	

290	

270	

504	

88	

25,00	

2 x ISO-M20	

A

SFDE500 IA	

485	

425	

290	

270	

504	

88	

21,00	

2 x ISO-M20	

A

Reference details

A

F

C

E

B

D

A

2 x ISOM20

2 x ISOM20

110 110
110 110

SFD250HPS

SFD400MH

SFD500IA

REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics

showed on this bulletin can be considered as binding on our confirmation only.

Since 1961

26 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
FLOODLIGHTS FOR INCANDESCENT
AND DISCHARGE LAMPS

Explosion Proof Electrical Equipment

RCDE

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D

FLOODLIGHT / PROJECTOR
ATEX 94/9/EC
EXECUTION

GOST-R (RTR / RTN)

GOST-K

1Ex d IIC T4/T3/T X
DIP A21 TA 200°C,
DIP A21 TA (135, 160, 200, 230)°C

1Ex d IIC T4/T3/T2 X
DIP A21 TA (135, 160, 200, 230)°C

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

IP66

IP66

IP66

INERIS 03 ATEX 0004 X

POCC IT. ГБ05.B02536

No. 07/43-269

EN 60079-0; EN 60079-1; EN 61241-1

ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99

ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002

II 2 G Ex d IIC T4/T3/T2
II 2 D Ex tD A21 T135°C/T160°C T200°C/T230°C

INSTALLATION
PROTECTION DEGREE
CERTIFICATE REF.
RULES OF COMPLIANCE

CONTROL GEAR
ATEX 94/9/EC

GOST-R (RTR / RTN)

GOST-K

1Ex d IIC T6 (T5…T2) X
DIP A21 TA (80…290)°C

1Ex d IIC T6 (T5…T2) X
DIP A21 TA (80…290)°C

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

IP66

IP66

IP66

INERIS 01 ATEX 0054X

POCC IT. ГБ05.B02536

No. 07/43-269

EN 60079-0; EN 60079-1; EN 61241-1

ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99

ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002

II 2 G Ex d IIC T6/T2
II 2 D Ex tD A21 T80°C/T290°C

EXECUTION
INSTALLATION
PROTECTION DEGREE
CERTIFICATE REF.
RULES OF COMPLIANCE

Mechanical characteristics
Body	

marine grade copper free aluminium

Diffuser	

tempered front glass

Support	

adjustable type hot dip galvanized steel

Reflector	

internal polished aluminium

Painting	

external epoxy powders grey ral-9006 colour

Screws	

external stainless steel

Gaskets	

silicon rubber

Cable entry	

3/4” npt size threaded

Electrical characteristics
Power supply 	

conventional ballast 230V - 50Hz (p.f.corrected - cos ρ ≥ 0,95)

Lampholders	

porcelain E40 size

Internal wiring	

high-temperature resistant silicon rubber insulation cables

Terminals	

suitable up to 4mm/sq cables

On Request Accessories:
• External painting colour on request
• Control gear with voltage supply different than standard
• Threaded cable entry different than standard
Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 27

RCDE

Ex Lighting
Ex Lighting

RCDE Technical data
TEMPERATURE CLASS
(GAS)

LAMP

TEMPERATURE CLASS
(DUSTS)

LAMPHOLDER
SIZE

CABLE ENTRY
SIZE

DETAIL

1x3/4”	

A

1x3/4”	

A		

FLOODLIGHTS FOR INCANDESCENT LAMP - POWER SUPPLY 230V-50Hz
RECDE500	

500 W 	

T2	

RECDE500	

500 W 	

T 230°C 	

E-40	

FLOODLIGHTS FOR BLENDED LIGHT LAMP - POWER SUPPLY 230V-50Hz
T3	

T 200°C 	

E-40	

FLOODLIGHTS FOR HIGH PRESSURE MERCURY VAPOUR LAMP - POWER SUPPLY 230V-50Hz
RECDE500 250HG	

250 W 	

T3	

T 160°C 	

E-40	

3x3/4”	

B	

RECDE500 400HG	

400 W 	

T3	

T 200°C 	

E-40 	

3x3/4”	

B	

FLOODLIGHTS FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V-50Hz
RECDE500 250HPNA	 250 W	

T4 	

RECDE500 400HPNA	 400 W	

T3

T 135°C 	

3x3/4”	

B

T 200°C 	

	

E-40	
E-40	

3x3/4”	

B

FLOODLIGHTS FOR METAL HALIDE LAMP - POWER SUPPLY 230V-50Hz
RECDE500 250MH	

250 W	

T4

	

T 135°C 	

E-40	

3x3/4”	

B

RECDE500 400MH	

400 W	

T3

	

T 200°C 	

E-40	

3x3/4”	

B	

WEIGHT [Kg] CABLE ENTRY

DETAIL

RCDE Technical features
CODE

A [mm]

RECDE500	
RECDE500 250HG	

542	
542	

B [mm]

C [mm]

D [mm]

378	
378	

376	
406	

-	
700	

21,00	
29,00	

1 x 3/4”	
3 x 3/4”	

A
B

RECDE500 250HPNA	

542	

378	

406	

700	

29,50	

3 x 3/4”	

B

RECDE500 400HG	

542	

378	

406	

700	

31,00	

3 x 3/4”	

B

RECDE500 400HPNA	

542	

378	

406	

700	

31,50	

3 x 3/4”	

B

RECDE500 250MH	

542	

378	

406	

700	

26,50	

3 x 3/4”	

B

RECDE500 400MH	

542	

378	

406	

700	

31,50	

3 x 3/4”	

B

B

1x3/4”

1x3/4”
2x3/4”
with PLG2

B

A

D

A

B

A

RCDE

CODE

C

RCDE250MH

220
220

C

RCDE250HG

RCDE250HPS

REMARK: Due to the development of the national and international specifications and of the technology, the above technical

characteristics showed on this bulletin can be considered as binding on our confirmation only.

Since 1961

28 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
Explosion Proof Electrical Equipment

Ex Lighting

EVO - EVT - TLF

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D

PORTHOLE LIGHTING FIXTURE (EVO)
ATEX 94/9/EC
EXECUTION

GOST-R (RTR / RTN)

GOST-K

1Ex d IIC T3 X, DIP A21 TA 200°C

1Ex d IIC T3 X, DIP A21 TA 200°C

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

IP66

IP66

IP66

INERIS 01 ATEX 0039 X

POCC IT. ГБ05.B02536

No. 07/43-269

EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1

ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99

ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002

II 2 G Ex d IIC T3,

INSTALLATION
PROTECTION DEGREE
CERTIFICATE REF.
RULES OF COMPLIANCE

II 2 D Ex tD A21 T200°C

LIGHTING FIXTURE (EVT)
ATEX 94/9/EC
EXECUTION

GOST-R (RTR / RTN)

GOST-K

1Ex d IIC T4, DIP A21 TA 135°C

1Ex d IIC T4, DIP A21 TA 135°C

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

IP66

IP66

IP66

INERIS 01 ATEX 0040

POCC IT. ГБ05.B02536

No. 07/43-269

EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1

ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99

ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002

II 2 G Ex d IIC T4,

INSTALLATION
PROTECTION DEGREE
CERTIFICATE REF.
RULES OF COMPLIANCE

II 2 D Ex tD A21 T135°C

LIGHTING FIXTURE (TLF)
ATEX 94/9/EC

GOST-R (RTR / RTN)

GOST-K

II 2 G Ex d / Ex de IIB T3
II 2 D Ex tD A21 T200°C

1Ex d IIB T3, 2Ex de IIB T3
DIP A21 TA 200°C

1Ex d IIB T3, 2Ex de IIB T3
DIP A21 TA 200°C

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

IP65

IP65

IP65

INERIS 01 ATEX 0026

POCC IT. ГБ05.B02536

No. 07/43-269

EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1

ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99

ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002

EXECUTION
INSTALLATION
PROTECTION DEGREE
CERTIFICATE REF.
RULES OF COMPLIANCE

Mechanical characteristics
Body	

marine grade copper free aluminium

diffuser	

borosilicate frontal glass (evt)

diffuser	

tempered frontal glass (evo - tlf)

painting	

external epoxy powders grey ral-9006 colour

screws	

external stainless steel

gaskets	

silicon rubber

cable entry	

3/4” npt size threaded

protection guard	

galvanized wire steel (evt only)

Electrical characteristics
Power supply 	

standard voltage 230v - 50hz

lampholders	

porcelain e27 size

internal wiring	

high-temperature resistant silicon rubber insulation cables

On Request Accessories:
•	External painting colour on request
•	Threaded cable entry different than standard
Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 29

EVO - EVT - TLF

LIGHTING FIXTURES
FOR INCANDESCENT LAMPS
EVO – EVT - TLF Technical data
CODE

LAMP

TEMPERATURE CLASS
(GAS)

TEMPERATURE CLASS
(DUSTS)

LAMPHOLDER
SIZE

CABLE ENTRY
SIZE

DETAIL

LIGHTING FIXTURE FOR INCANDESCENT LAMP - POWER SUPPLY 230V-50Hz
EVO100	

100 W	

T3

EVT100	

100 W	

T4

TLF100		

100 W	

	

T3

T 200°C 	

E-27	

1x3/4”	

	

T135°C 	

E-27	

2x3/4”	

B

	

T 200°C 	

E-27	

2x3/4”	

C

A

EVO – EVT - TLF Technical features
CODE

A [mm]

B [mm]

C [mm]

WEIGHT [Kg]

CABLE ENTRY

DETAIL

EVO100	

Ø140	

185	

Ø162	

2,00	

1 x 3/4”	

A

EVT100	

Ø233	

180	

155	

4,00	

2 x 3/4”	

B

TLF100	

309	

127	

165	

3,00	

2 x 3/4”	

C

Reference details
1 x 3/4”

B

Ø
C

A

C

2 x 3/4”

B

B

ØA

A

C

A

C

2 x 3/4”

B

EVO - EVT - TLF

Ex Lighting

REMARK:

Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.
Since 1961

30 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
LIGHTING FIXTURES FOR HIGH
EFFICENCY LED LAMPS
AND FLUORESCENT TUBE LAMPS

Explosion Proof Electrical Equipment

EXL

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D

LIGHTING FIXTURE
ATEX 94/9/EC

GOST-R (RTR / RTN)

GOST-K

1Ex d IIB T6, 1Exd [ia/ib] IIB T6,
DIP A21 TA 85°C

1Ex d IIB T6, 1Exd [ia/ib] IIB T6,
DIP A21 TA 85°C

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

IP66

IP66

IP66

IMQ 09 ATEX 020

POCC IT. ГБ05.B02537

No. 07/43-269

EN 60079-0; EN 60079-1; EN 61241-0;
EN 61242-1

ГОСТ Р 51330.9-99 (МЭК 660079-10-95)
ГОСТ Р 51330.13-99 (МЭК 660079-14-96)
ГОСТ Р МЭК 61241-3-99

ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002

II 2 G Ex d IIB T6
II 2 D Ex tD A21 T85°C

EXECUTION
INSTALLATION
PROTECTION DEGREE
CERTIFICATE REF.
RULES OF COMPLIANCE

Mechanical characteristics
Body	

marine grade copper free aluminium

Diffuser	

high-temperature resistant borosylicate glass

painting	

external epoxy powders grey ral-9006 colour

screws	

external stainless steel

reflectors	

white stove enamelled sheet steel

cable entry	

3/4” npt size threaded c/w cable gland

Electrical characteristics
Power supply	
lampholders	
internal wiring	

elettronic ballast 220V/240V - 50/60Hz (p.f.corrected - cos ρ ≥ 0,98)
bi-pin G5 cap (fluorescent lamp only)
high-temperature resistant silicon rubber insulation cables

terminals	

suitable up to 4mm/sq cables

emergency unit	
	

emergency unit with inverter charger and Ni-Cd battery pack
see technical features for more details

Functional characteristics

· EXL08ESA (Always ON - Maintained): 8W fluorescent lamp and electronic ballast 230V AC and emergency unit 3.6 V - 2Ah for an autonomy of 2 hours
3.6 V - 4Ah for an autonomy 3 hours

· EXL08E (Emergency only - Maintained): 8W fluorescent lamp and emergency unit 3.6 V - 2Ah with autonomy 3 hours
· EXL08L (Network only - Not Maintained): with high brightness LEDs (350mA - 4,8 W) Supply from 120V to 240V AC / DC
· EXL08LE (Emergency only - Maintained): with high brightness LEDs (350mA - 4,8 W) 220/240V AC and emergency unit 6V - 2Ah for an
autonomy of 3 hours complete with charge status monitor LED system (RED: battery under charging – GREEN: battery loaded)

Remarks

· EXL08E / EXL08ESA - 8W fluorescent lamp: emergency light intensity is 40% of light intensity with networking power supply
· EXL08LE - with high brightness LEDs (350mA -4.8 W): emergency light intensity is 100% of light intensity with networking power supply

On Request Accessories:
•	External painting colour on request
•	Electronic ballast with voltage supply different than standard

•	Threaded cable entry different than standard
•	Self-adhesive green label with EXIT sign (language on request)

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 31

EXL

Ex Lighting
Ex Lighting

EXL Technical data
POWER SUPPLY

LAMP

mA (LED)

TEMPERATURE CLASS
(GAS)

TEMPERATURE CLASS
(DUSTS)

EMERGENCY
UNIT

AUTONOMY

LIGHTING FIXTURES FOR FLUORESCENT TUBE LAMPS
EXL08		

220 ÷ 240V AC	

8W	

-	

T6	

T 85°C	

-	

-

EXL08E-3	

220 ÷ 240V AC	

8W	

-	

T6	

T 85°C	

3,6V - 4A/h	

3h

EXL08ESA-3	

220 ÷ 240V AC	

8W	

-	

T6	

T 85°C	

3,6V - 4A/h	

3h

EXL08L		

120 ÷ 240V AC/DC	

4,8 W	

350	

T6	

T 85°C	

-	

-

EXL08LE	

220 ÷ 240V AC	

4,8 W	

350	

T6	

T 85°C	

3,6V - 2A/h	

3h

EXL208L	

120 ÷ 240V AC/DC	

9,16 W	

350	

T6	

T 85°C	

-	

-

LIGHTING FIXTURES FOR HIGH EFFICENCY LED LAMPS

EXL Technical features
E [mm]

WEIGHT [Kg]

CABLE ENTRY

DETAIL

EXL08	

CODE

A [mm]
380	

B [mm]
170	

C [mm]
125	

D [mm]
370	

125	

8,00	

1 x 3/4”	

A

EXL08E-3	

380	

170	

125	

370	

125	

8,00	

1 x 3/4”	

A

EXL08ESA-3	

380	

170	

125	

370	

125	

8,00	

1 x 3/4”	

A

EXL08L	

380	

170	

125	

370	

125	

8,00	

1 x 3/4”	

A

EXL08LE	

380	

170	

125	

370	

125	

8,00	

1 x 3/4”	

A

EXL208L	

380	

170	

125	

370	

125	

8,00	

1 x 3/4”	

A

Reference details

A

A

C

E

B

EXL

CODE

D

3/4"

EXL On request accessories
CODE

DESCRIPTION

EXL-08

MATERIAL

SELF-ADHESIVE GREEN “EXIT” LABEL	

2070.00088	

POLYESTER

EXL-08L

EXL2-08L

REMARK: Due to the development of the national and international specifications and of the technology, the above technical

characteristics showed on this bulletin can be considered as binding on our confirmation only.

Since 1961

32 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
LIGHTING FIXTURES FOR
FLUORESCENT TUBE LAMPS

Explosion Proof Electrical Equipment

EVG

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D

18W LIGHTING FIXTURE
ATEX 94/9/EC

GOST-R (RTR / RTN)
2Ex edq IIC T4 (T6)
DIP A21 TA 80°C

II 2 G Ex edq IIC T4
II 2 D Ex tD A21 T 80°C

EXECUTION
AMBIENT TEMPERATURE

36W LIGHTING FIXTURE
ATEX 94/9/EC
II 2 G Ex edq IIC T4
II 2 D Ex tD A21 T 80°C

-20°C ÷ +60°C

-20°C ÷ +60°C

IP66

IP66

IP66/64

PTB 97 ATEX 2223

POCC DE. ГБ05.B01788

PTB 07 ATEX 2040

EN 60079-0; EN 60079-1;
EN 61241-0; EN 61242-1

ГОСТ Р 51330.9-99 (МЭК 660079-10-95)
ГОСТ Р 51330.13-99 (МЭК 660079-14-96)
ГОСТ Р МЭК 61241-3-99

EN 60079-0; EN 60079-1;
EN 61241-0; EN 61242-1

PROTECTION DEGREE
CERTIFICATE REF.
RULES OF COMPLIANCE

LIGHTING FIXTURES WITH
EMERGENCY UNIT ONLY

58W LIGHTING FIXTURE
ATEX 94/9/EC

GOST-R (RTR / RTN)

II 2 G Ex edq IIC T4
II 2 D Ex tD A21 T 90°C

EXECUTION
AMBIENT TEMPERATURE

-20°C ÷ +55°C

2Ex edq IIC T4 (T6)
DIP A21 TA 90°C

ATEX 94/9/EC
II 2 GD Ex edq IIC T4 T80°C

-20°C ÷ +60°C

-20°C ÷ +60°C

IP66

IP66

IP66/64

PTB 97 ATEX 2225

POCC DE. ГБ05.B01788

PTB 05 ATEX 2066

EN 60079-0; EN 60079-1;
EN 61241-0; EN 61242-1

ГОСТ Р 51330.9-99 (МЭК 660079-10-95)
ГОСТ Р 51330.13-99 (МЭК 660079-14-96)
ГОСТ Р МЭК 61241-3-99

EN 60079-0; EN 60079-1;
EN 61241-0; EN 61242-1

PROTECTION DEGREE
CERTIFICATE REF.
RULES OF COMPLIANCE

-20°C ÷ +55°C

Mechanical characteristics
Body	

glass fibre reinforced polyester resin

diffuser	

u/v resistant polycarbonate - hinged to body

safety closing	

operated by triangular key

gaskets	

epdm rubber suitable for high temperatures and resistant to enviroments conditions

internal reflector	

white polyester highly refractor diffuser

cable entry	

iso-metric thread c/w plastic cable glands and stopping plug

Electrical characteristics
Power supply	

elettronic ballast 220v/240v - 50/60hz (p.f.corrected - cos ρ ≥ 0,98)

lampholders	

bi-pin g13 cap

internal wiring	

high-temperature resistant silicon rubber insulation cables

terminals	

suitable up to 6mm/sq cables

safety feature	
emergency unit	
	

“end of life” switching-off system in according to en 60079-7 rules
emergency unit composed of inverter charger and ni-cd battery pack 7a/h 6v
autonomy up to 180 min.

advantages	

see table “advantage features”

On Request Accessories:
•Pole mounting kit complete with stainless steel hardware
•Ceiling mounting kit complete with stainless steel hardware

•Pendant mounting kit complete with stainless steel hardware
•Wall/Structure mounting kit complete with stainless steel hardware
•Electronic ballast with voltage supply different than standard

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 33

EVG

Ex Lighting
Ex Lighting

EVG Technical data
LAMP

EVG

CODE

TEMPERATURE CLASS
(GAS)

TEMPERATURE CLASS
(DUSTS)

LAMPHOLDER

CABLE ENTRY

EMERGENCY
UNIT

AUTONOMY

DETAIL

FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50/60Hz
SH-21EVG	

1 x 18W	

T4 (Ta = -20°C / +60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

-	

-	

A

SH-41EVG	

1 x 36W	

T4 (Ta = -20°C / +60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

-	

-	

A

SH-61EVG	

1 x 58W	

T4 (Ta = -20°C / +60°C)	

T 90°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

-	

-	

A

SH-22EVG	

2 x 18W	

T4 (Ta = -20°C / +60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

-	

-	

A

SH-42EVG	

2 x 36W	

T4 (Ta = -20°C / +60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

-	

-	

A

SH-62EVG	

2 x 58W	

T4 (Ta = -20°C / +60°C)	

T 90°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

-	

-	

A

EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50/60Hz
SH-22EVG-E	

2 x 18W	

T4 (Ta = -20°C / +60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

2 x ISO-M25	

6 V - 7 A/h	

3h	

B

SH-42EVG-E	

2 x 36W	

T4 (Ta = -20°C / +60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

2 x ISO-M25	

6 V - 7 A/h	

3h	

B

EVG Technical features
CODE

A [mm]

B [mm]

C [mm]

D [mm]

WEIGHT [Kg]

CABLE ENTRY

DETAIL

SH-21EVG	

786	

160	

214	

600	

10,00	

3 x ISO-M25	

A

SH-41EVG	

1355	

150	

226	

716	

13,00	

3 x ISO-M25	

A

SH-61EVG	

1696	

160	

214	

800	

16,00	

3 x ISO-M25	

A

SH-22EVG	

786	

160	

214	

600	

10,50	

3 x ISO-M25	

A

SH-42EVG	

1355	

150	

226	

716	

13,50	

3 x ISO-M25	

A

SH-62EVG	

1696	

160	

214	

800	

16,50	

3 x ISO-M25	

A

SH-22EVG-E	

913	

160	

221	

600	

9,40	

2 x ISO-M25	

B

SH-42EVG-E	

1523	

160	

221	

800	

12,80	

2 x ISO-M25	

B

Reference details

A

B

D

C

A

B

B

D

C

A

Since 1961

34 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
Ex Lighting

EVG Installation and mounting details
type 1

type 2

Wall/structure mounting

type 3

type 4

00

Pendant mounting

EVG

Ceiling mounting

Pole mounting
Assemblig detail with pole (typical)

1

50

100

45°

EVG Polar diagrams – photometric data
SH-21EVG

SH-22EVG

SH-41EVG

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 35
Ex Lighting

EVG Polar diagrams – photometric data
SH-61EVG

SH-62EVG

EVG

SH-42EVG

EVG with emergency unit
LIGHTING FIXTURES AND EMERGENCY UNIT ELECTRICAL DESIGN AND SPECIAL FEATURES	
Microprocessor (plc)	

“end-of life” switching-off system at the end of life a fluorescent tube lamp is safely switched off

	

(according to iec en-60079-7 stds)

Multi-function led	

multi-function led indcator with coded indication of the functions, status and potential failures of the

	

electronic device and of the batteries

Monitoring	

special signal whenever there is a e.o.l. situation (led red flashing )

	

automatic weekly functions test

	

automatic annual 2/3 times operating period test

	

function and operating period test can be done manually also

Maintenance	

quick replacement of battery set even in explosive atmosphere presence

	

electrical disconnection whenever the batteries box is opened

	

24h max recharging time (in according to en-60598-2-22)

Safety	

Highest degree of safety in case of lamp failure during the emergency light operation

	
	
	

In case of lamp failure during emergency operation the second tube lamp will automatically take over the
emergency operation (two lamps version only)

EVG On request accessories
CODE

DESCRIPTION

INSTALLATION

MATERIAL

20301.0162	

POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE	

TYPE 4	

GALVANIZED STEEL

20301.0163	

POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE	

TYPE 4	

GALVANIZED STEEL

20301.0165	

PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS	

TYPE 2	

STAINLESS STEEL

20302.0121	

CEILING MOUNTING KIT C/W HARDWARE	

TYPE 1	

GALVANIZED STEEL

20302.0128	

WALL/STRUCTURE MOUNTING KIT C/W HARDWARE	

TYPE 3	

GALVANIZED STEEL

REMARK:

Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.
Since 1961

36 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
FLUORESCENT LIGHTING
FIXTURES FOR CEILING
OR RECESSED INSTALLATION

Ex Lighting

e191 - e192

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D

LIGHTING FIXTURE
ATEX 94/9/EC
II 2G Ex edq IIC T4
II 2D Ex tD A21 T 80°C

EXECUTION
AMBIENT TEMPERATURE

GOST-R (RTR / RTN)
2Ex edq IIC T4, 2Ex eq II T4,
DIP A21 TA 80°C

-20°C ÷ +60°C (e191… - e192... surface/recessed in suspend. ceiling)
-20°C ÷ +50°C (e191… recessed mount. insulated)
-20°C ÷ +40°C (e192... recessed mount. insulated)

PROTECTION DEGREE

-20°C ÷ +40°C

IP65

IP65

IBExU 04 ATEX 1062

POCC DE. ГБ05.B01788

EN 50014 +A1 +A2; EN 50017; EN 50018;
EN 50019; EN 50281-1-1

ГОСТ Р 51330.9-99 (МЭК 660079-10-95)
ГОСТ Р 51330.13-99 (МЭК 660079-14-96)
ГОСТ Р МЭК 61241-3-99

CERTIFICATE REF.
RULES OF COMPLIANCE

Mechanical characteristics
Body	

sheet steel white coloured ral 9016

diffuser	

safety toughened impact resistant tempered glass hinged to body

safety closing	

central locking system operated by 5mm allen key - hinges on opposite side

gaskets	

epdm rubber suitable for high temperatures and resistant to enviroments conditions

internal reflector	

high anodized purest aluminium

cable entry	

iso-metric thread c/w plastic cable glands and stopping plug

Electrical characteristics
Power supply	

dual channel elettronic ballast 220v/240v-50/60hz (p.f.corrected - cos ρ ≥ 0,98) - DC

lampholders	

bi-pin g13 cap

internal wiring	

high-temperature resistant silicon rubber insulation cables

terminals	

suitable up to 6mm/sq cables

isolating switch	

switching off all poles when lighting fitting is opened showing the actual position by optical indicator

Safety feature	

“END OF LIFE” switching-off system in according to EN 60079-7 rules

On Request Accessories:
•Recessed mounting kit EB182 series complete with stainless steel hardware
•Stainless steel sheet body
•Electronic ballast with voltage supply different than standard

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 37

e191- e192

Explosion Proof Electrical Equipment
e191 - e192 Technical data
CODE

TEMPERATURE CLASS
(GAS)

LAMP

TEMPERATURE CLASS
(DUSTS)

LAMPHOLDER

CABLE ENTRY

DETAIL

FLUORESCENT LIGHTING FIXTURES - POWER SUPPLY 220-240V-50/60Hz - DC
e19121		

1 x 18W	

T4 (Ta = -20°C ÷ 40/50/60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

A

e19122		

2 x 18W	

T4 (Ta = -20°C ÷ 40/50/60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

A

e19141		

1 x 36W	

T4 (Ta = -20°C ÷ 40/50/60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

A

e19142		

2 x 36W	

T4 (Ta = -20°C ÷ 40/50/60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

A

e19161		

1 x 58W	

T4 (Ta = -20°C ÷ 40/50/60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

A

e19162		

2 x 58W	

T4 (Ta = -20°C ÷ 40/50/60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

A

e19223		

3 x 18W	

T4 (Ta = -20°C ÷ 40/50/60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

A

e19224		

4 x 18W	

T4 (Ta = -20°C ÷ 40/50/60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

A

e19243		

3 x 36W	

T4 (Ta = -20°C ÷ 40/50/60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

A

e19244		

4 x 36W	

T4 (Ta = -20°C ÷ 40/50/60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

A

e19263		

3 x 58W	

T4 (Ta = -20°C ÷ 40/50/60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

A

e19264		

4 x 58W	

T4 (Ta = -20°C ÷ 40/50/60°C)	

T 80°C (Ta = -20°C / +60°C)	

G13	

3 x ISO-M25	

A

e191 - e192 Lighting fixture technical features
CODE

A [mm]

B [mm]

C [mm]

D [mm]

E [mm]

WEIGHT [Kg] CABLE ENTRY

DETAIL

e19121	

720	

82	

368	

600	

404	

10,00	

3 x ISO-M25	

A

e19122	

720	

82	

368	

600	

404	

10,00	

3 x ISO-M25	

A

e19141	

1330	

82	

368	

1200	

404	

15,50	

3 x ISO-M25	

A

e19142	

1330	

82	

368	

1200	

404	

15,50	

3 x ISO-M25	

A

e19161	

1630	

82	

368	

1400	

404	

18,00	

3 x ISO-M25	

A

e19162	

1630	

82	

368	

1400	

404	

18,00	

3 x ISO-M25	

A

e19223	

720	

82	

500	

600	

536	

18,50	

3 x ISO-M25	

A

e19224	

720	

82	

500	

600	

536	

18,50	

3 x ISO-M25	

A

e19243	

1330	

82	

500	

1200	

536	

25,50	

3 x ISO-M25	

A

e19244	

1330	

82	

500	

1200	

536	

25,50	

3 x ISO-M25	

A

e19263	

1630	

82	

500	

1400	

536	

28,50	

3 x ISO-M25	

A

e19264	

1630	

82	

500	

1400	

536	

28,50	

3 x ISO-M25	

A

Lighting fixture Reference details

A

E

Ø9

D

B

e191- e192 e192
e191-

Ex Lighting

C

A

Since 1961

38 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
e191 - e192 Recessed frame technical features
CODE

LUMINARIE TYPE

	
EB182-18
	

e19121	

388	

740	

786	

93	

300	

434	

82	

9

e19122	

388	

740	

786	

93	

300	

434	

82	

9

	
EB182-36
	

e19141	

388	

1350	

1396	

98	

400	

434	

82	

9

e19142	

388	

1350	

1396	

98	

400	

434	

82	

9

e19161	

388	

1650	

1696	

48	

400	

434	

82	

9

	
EB182-58
	

A [mm]

B [mm]

C [mm]

D [mm]

E [mm]

F [mm]

G [mm]

H [mm]

e19162	

388	

1650	

1696	

48	

400	

434	

82	

9

	
EB192-18
	

e19223	

520	

740	

786	

93	

300	

566	

82	

9

e19224	

520	

740	

786	

93	

300	

566	

82	

9

	
EB192-36
	

e19243	

520	

1350	

1396	

96	

400	

566	

82	

9

e19244	

520	

1350	

1396	

96	

400	

566	

82	

9

	
EB192-58
	

e19263	

520	

1650	

1696	

48	

400	

566	

82	

9

e19264	

520	

1650	

1696	

48	

400	

566	

82	

9

Recessed frame Reference details
B

G

A

H

F

C

D

E

E

E

D

e191 - e192 Polar diagrams – photometric data
e191-42

e192-43

e192-44

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 39

e191- e192

Ex Lighting
e191- e192

Ex Lighting

e191 - e192 Polar diagrams – photometric data
e191-22

e191-23

e191-64

e191 - e192 On request accessories
CODE

DESCRIPTION

MATERIAL

EB182-18	

RECESSED FRAME FOR LIGHTING FIXTURE 1x18W AND 2x18W

		

PAINTED SHEET STEEL

EB182-36	

RECESSED FRAME FOR LIGHTING FIXTURE 1x36W AND 2x36W

		

PAINTED SHEET STEEL

EB182-58	

RECESSED FRAME FOR LIGHTING FIXTURE 1x58W AND 2x58W		

PAINTED SHEET STEEL

EB192-18	

RECESSED FRAME FOR LIGHTING FIXTURE 3x18W AND 4x18W

		

PAINTED SHEET STEEL

EB192-36	

RECESSED FRAME FOR LIGHTING FIXTURE 3x36W AND 4x36W

		

PAINTED SHEET STEEL

EB192-58	

RECESSED FRAME FOR LIGHTING FIXTURE 3x58W AND 4x58W		

PAINTED SHEET STEEL

REMARK:

Due to the development of the national and international specifications and of the technology, the above technical characteristics showed
on this bulletin can be considered as binding on our confirmation only.

Since 1961

40 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
INCREASED SAFETY LIGHTING
FIXTURES FOR BI-PIN
FLUORESCENT LAMPS

Explosion Proof Electrical Equipment

AVF

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D

LIGHTING FIXTURE
ATEX 94/9/EC

GOST-R (RTR / RTN)

GOST-K

2Ex ed IIC T5
DIP A21 TA 70°C

2Ex ed IIC T5
DIP A21 TA 70°C

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

IP66

IP66

IP66

KEMA 01 ATEX 2069

POCC IT. ГБ05.B02536

No. 07/43-269

EN 60079-0; EN 60079-1;
EN 60079-7; EN 61241-1

ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99

ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002

II 2 G Ex ed IIC T5
II 2 D Ex tD A21 T70°C

EXECUTION
INSTALLATION
PROTECTION DEGREE
CERTIFICATE REF.
RULES OF COMPLIANCE

EMERGENCY UNIT
ATEX 94/9/EC

GOST-R (RTR / RTN)

GOST-K

1Ex ed IIB T6
DIP A21 TA 85°C

1Ex ed IIB T6
DIP A21 TA 85°C

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

ZONE 1 / 2 - ZONE 21 / 22

IP66

IP66

IP66

IMQ 08 ATEX 026X

POCC IT. ГБ05.B02537

No. 07/43-269

EN 60070-0; EN 60079-7;
EN 61241-0; EN 61241-1;

ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99

ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002

II 2 G Ex ed IIC T6
II 2 D Ex tD A21 T85°C

EXECUTION
INSTALLATION
PROTECTION DEGREE
CERTIFICATE REF.
RULES OF COMPLIANCE

Mechanical characteristics
Body	

galss fibre reinforced polyester resin self-extinguishing acc. to UL94

Diffuser	

U/V resistant polycarbonate - hinged to body

Safety closing	

operated by hexagonal key

Gaskets	

EPDM 60 rubber suitable for high temperatures and resistant to enviroments conditions

Internal reflector	

white stove enamelled sheet aluminum

Cable entry	

ISO-Metric complete with cable glands and plug

Electrical characteristics
Power supply	

elettronic ballast 220V/240V 50/60Hz (p.f. corrected - cos ρ ≥ 0,98)

Lampholders	

bi-pin G13 cap

Internal wiring	

high-temperature resistant silicon rubber insulation cables

Terminals	

suitable up to 6mm/sq cables

Safety feature	

EEx de safety switch

On Request Accessories:
•	Pole mounting kit complete with stainless steel hardware
•	Ceiling mounting kit complete with stainless steel hardware
•	Pendant mounting kit complete with stainless steel hardware

• Wall/Structure mounting kit complete with stainless steel hardware
• Electronic ballast with voltage supply different than standard
• AUTOTEST electronic system for emergency unit

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 41

AVF

Ex Lighting
Ex Lighting

AVF Technical data
LAMP

AVF

CODE

TEMPERATURE CLASS
(GAS)

TEMPERATURE CLASS
(DUSTS)

CABLE
ENTRY

LAMPHOLDER

EMERGENCY
UNIT

AUTONOMY

DETAIL

FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V 50/60Hz
AVF 118		

1 x 18W 	

T5

	

T 70°C	

G13	

3 x M20 x 1,5	

-	

-	

A

AVF 136	

1 x 36W 	

T5

	

T 70°C	

G13	

3 x M20 x 1,5	

-	

-	

A

AVF 218	

2 x 18W 	

T5

	

T 70°C	

G13	

3 x M20 x 1,5	

-	

-	

A

AVF 236	

2 x 36W 	

T5

	

T 70°C	

G13	

3 x M20 x 1,5	

-	

-	

A

EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V 50/60Hz
AVF 118-E	

1 x 18W 	

T5

	

T 70°C	

G13	

2 x M20 x 1,5	

4.8 V - 4Ah	

3h	

B

AVF 136-E	

1 x 36W 	

T5

	

T 70°C	

G13	

2 x M20 x 1,5	

4.8 V - 4Ah	

3h	

B

AVF 218-E	

2 x 18W 	

T5

	

T 70°C	

G13	

2 x M20 x 1,5	

4.8 V - 4Ah	

3h	

B

AVF 236-E	

2 x 36W 	

T5

	

T 70°C	

G13	

2 x M20 x 1,5	

4.8 V - 4Ah	

3h	

B

AVF Technical features
A [mm]

B [mm]

WEIGHT [Kg]

CABLE ENTRY

DETAIL

AVF 118	

CODE

730	

215	

160	

400	

6,00	

3 x M20 x 1,5	

A

AVF 136	

1340	

215	

160	

450	

6,50	

3 x M20 x 1,5	

A

AVF 218	

730	

215	

160	

400	

7,00	

3 x M20 x 1,5	

A

AVF 236	

1340	

215	

160	

450	

7,50	

3 x M20 x 1,5	

A

CODE

C [mm]

C [mm]

D [mm]

A [mm]

B [mm]

WEIGHT [Kg]

CABLE ENTRY

DETAIL

AVF 118-E	

925	

215	

280	

D [mm]
400	

11,00	

2 x M20 x 1,5	

B

AVF 136-E	

1535	

215	

280	

450	

11,50	

2 x M20 x 1,5	

B

AVF 218-E	

925	

215	

280	

400	

12,00	

2 x M20 x 1,5	

B

AVF 236-E	

1535	

215	

280	

450	

12,50	

2 x M20 x 1,5	

B

Reference details

A
8MA

D

8MA

C

8MA

B

B

A

8MA

D

8MA

C

8MA

B

A

Since 1961

42 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
Ex Lighting

AVF Installation and mounting details
Ceiling mounting

Pendant mounting

type 2

Wall/structure mounting

type 3

type 4

0

10

AVF

type 1

Pole mounting
Assemblig detail with pole (typical)

50

100

45°

AVF Polar diagrams – photometric data
AVF218

AVF136

AVF236

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 43
Ex Lighting

AVF with emergency unit (design and special features)
AVF

GENERALITY:
The controller unit system permits to manage in AUTOTEST the verify of emergency unit working					
This system allows the emergency working of every fluorescent tube lamps (NON maintened working)				
The check and the control system has been realized by proper microprocessor which perform the following tests :			
- continuous test on the battery charger working, on the operation of the battery, and on presence of voltage supply			
- duration test in emergency working (every 3 months) with check of battery charge						
- test of emergency working (weekly) with check of right lamp operation	
				
Every information concerning the checks can be managed singly or tranmitted by “remote control system” in order to manage complete
illumination system test in centralized way.

Multicolor LED indicator in standard working (continuous led light)							
ON

ON

ON

ON

ON

ON

ON

ON

ON

Regular operation

ON

ON

ON

ON

ON

ON

ON

ON

ON

Failed battery performance check

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

Lack of main power supply

ON

ON

ON

OFF

ON

ON

ON

OFF

ON

Lack of battery

Multicolor LED indicator during test opetarion (intermittent led light)	
ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

Performing lamp test

ON

ON

OFF

ON

ON

OFF

ON

ON

OFF

Performing battery pack test

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

Failed lamp test

Multicolor LED indicator during batteries recharging phase						
ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

24 hours

ON

ON

ON

ON

ON

ON

ON

ON

ON

After 24 hours

AVF On request accessories
CODE

DESCRIPTION

INSTALLATION

MATERIAL

20301.0162	

POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE	

TYPE 4	

GALVANIZED STEEL

20301.0163	

POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE	

TYPE 4	

GALVANIZED STEEL

20301.0165	

PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS	

TYPE 2	

STAINLESS STEEL

20302.0121	

CEILING MOUNTING KIT C/W HARDWARE	

TYPE 1	

GALVANIZED STEEL

20302.0128	

WALL/STRUCTURE MOUNTING KIT C/W HARDWARE	

TYPE 3	

GALVANIZED STEEL

	

AUTOTEST electronic system	

-	

-

REMARK:

Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.

Since 1961

44 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
Explosion Proof Electrical Equipment

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D

Ex Lighting

SFDQL

FLOODLIGHT
ATEX 94/9/EC
II 2G Ex eq II T3
II 2D Ex tD A21 T 200°C

EXECUTION

-40°C ÷ +40°C
-40°C ÷ +60°C

AMBIENT TEMPERATURE
PROTECTION DEGREE

IP66

CERTIFICATE REF.

IMQ 09 ATEX 014X

RULES OF COMPLIANCE

EN 60079-0; EN 60079-5; EN 60079-7;
EN 61241-0; EN 61241-1

Mechanical characteristics
Body	

marine grade copper free aluminum

Diffuser	

tempered front glass

Support	

steel bracket with rotation-proof system

Reflector	

anodized and polished 99,85 pure aluminum internal optic

Painting	

thermosetting polyester powder resistant to atmospheric agents and corrosion grey RAL 9006 colour

Screws	

stainless steel

Gaskets	

pure silicon heat resistance

Cable entry	

iso-Metric complete with nikel plated brass cable gland M20

Electrical characteristics	
Power supply	

180 ÷ 230V DC / 180 ÷ 277V AC x 165W - 55W - 85W

Lamp	

long life induction lamp (60.000 hours)

Terminals	

suitable up to 4mm/sq cables

On Request Accessories:
•Power supply 90 ÷ 120V AC/DC (55/85W only)

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 45

SFDQL

FLOODLIGHT PROJECTORS
FOR INDUCTION LAMPS
Ex Lighting

SFDQL

SFDQL Technical data
CODE

TEMPERATURE CLASS
(GAS)

LAMP

TEMPERATURE CLASS
(DUSTS)

CABLE ENTRY SIZE

DETAIL

FLOODLIGHT FOR INDUCTION LAMP - POWER SUPPLY 220V/240V 50/60Hz - 220V/240V DC - 120V AC/DC
SFDQL-55JB	

55W 	

T3 (Ta = -40°C / +60°C)

	 T 200°C 	

2 x ISO M20	

A

SFDQL-85JB	

85W	

T3 (Ta = -40°C / +60°C)

	 T 200°C 	

2 x ISO M20	

A

SFDQL-55	

55W 	

T3 (Ta = -40°C / +60°C)

	 T 200°C 	

1 x PCE M20	

B

SFDQL-85	

85W	

T3 (Ta = -40°C / +60°C)

	 T 200°C 	

1 x PCE M20	

B

FLOODLIGHT FOR INDUCTION LAMP - POWER SUPPLY 220V/240V 50/60Hz - 220V/240V DC
SFDQL-165JB	

165W 	

T3 (Ta = -40°C / +40°C)

	 T 200°C 	

2 x ISO M20	

A

SFDQL-165	

165W	

T3 (Ta = -40°C / +40°C)

	 T 200°C 	

1 x PCE M20	

B

WEIGHT [Kg]

CABLE ENTRY

DETAIL

SFDQL Technical features
CODE

A [mm]

B [mm]

C [mm]

D [mm]

SFDQL-55JB	

430	

460	

545	

260	

8,50	

2 x ISO M20	

A

SFDQL-85JB	

430	

460	

545	

260	

8,70	

2 x ISO M20	

A

SFDQL-165JB	

430	

460	

545	

260	

9,50	

2 x ISO M20	

A

SFDQL-55	

430	

460	

545	

180	

8,00	

1 x PCE M20	

B

SFDQL-85	

430	

460	

545	

180	

8,20	

1 x PCE M20	

B

SFDQL-165	

430	

460	

545	

180	

9,00	

1 x PCE M20	

B

Reference details

A

A

D

II 2G Ex eq II T3
II 2D Ex tD A21 IP 66 T200° C

IMQ 08 ATEX 014X

www.feam-ex.com

INDUCTION LAMP

SFDQL

C

B

0722

55W
85W
165W

55W-85W
Ta -40° C / +60° C

180÷230V DC
180÷277V AC
90÷120V AC/DC

165W
Ta -40° C / +40° C

2 X ISO M20

0°
12

155

155

Since 1961

46 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
Ex Lighting

Reference details

B

A

D

II 2G Ex eq II T3
II 2D Ex tD A21 IP 66 T200° C

IMQ 08 ATEX 014X

www.feam-ex.com

INDUCTION LAMP

SFDQL

B

0722

C

55W
85W
165W

55W-85W
Ta -40° C / +60° C

180÷230V DC
180÷277V AC
90÷120V AC/DC

165W
Ta -40° C / +40° C

155

0°
12

1 X PCE M20

155

SFDQL Polar diagrams – photometric data
SFDQL55

SFDQL85

SFDQL165

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 47

SFDQL

SFDQL Technical features
Ex Lighting

SFDQL

SFDQL On request accessories
CODE

DESCRIPTION

20303.0099	

PROTECTION GRID	

20303.0100	

MATERIAL

POLE ADAPTER - DIA. 40÷60mm	

Protection grid

20303.0099

ALUMINUM
PAINTED STEEL

Pole adapter

20303.0100

REMARK:

Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.

Since 1961

48 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
LIGHTING FIXTURES FOR
FLUORESCENT TUBE LAMPS

Explosion Proof Electrical Equipment

EVSN

Installation: hazardous areas - Zone 2 (Gases) - Zone 22 (Dusts)
Classification: Group II - Category 3G 3D

LIGHTING FIXTURE

EMERGENCY UNIT

ATEX 94/9/EC

ATEX 94/9/EC
II 2 G Ex ed IIC
II 2 D Ex tD A21 T85°C

II 3 G Ex nA II T6/T5
II 3 D Ex tD A22 T85°C/T100°C

EXECUTION
AMBIENT TEMPERATURE

ZONE 2 - ZONE 22

INSTALLATION

-40°C ÷ +55°C
ZONE 1 / 2 - ZONE 21 / 22

PROTECTION DEGREE

IP65

IP66

IMQ 08 ATEX 008X

IMQ 08 ATEX 026X

EN 60079-0; EN 60079-15; EN 61241-0; 61241-1

EN 60070-0; EN 60079-7; EN 61241-0; EN 61241-1

CERTIFICATE REF.
RULES OF COMPLIANCE

Mechanical characteristics
Body	

glass fibre reinforced polyester resin

Diffuser	

U/V resistant polycarbonate - hinged to body

Safety closing	

stainless steel hooks with safety device

Gaskets	

EPDM 60 rubber suitable for high temperatures and resistant to enviroments conditions

Internal reflector	

white stove enamelled sheet steel

Cable entry	

complete with PVC cable gland

Electrical characteristics
Power supply	

dual channel electronic ballast 220/240V 50/60Hz (cos ρ ≥ 0,98)

Lampholders	

bi-pin G13 cap

Terminals	

suitable up to 6mm/sq cables

On Request Accessories:
• Pole mounting kit complete with stainless steel hardware
• Ceiling mounting kit complete with stainless steel hardware
• Pendant mounting kit complete with stainless steel hardware
• Wall/Structure mounting kit complete with stainless steel hardware

• Electronic ballast with voltage supply different than standard
• Ex-de safety switch
• AUTOTEST electronic system for emergency unit

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 49

EVSN

Ex Lighting
Ex Lighting 	

EVSN Technical data
EVSN

CODE

LAMP

TEMPERATURE CLASS
(GAS)

TEMPERATURE CLASS
(DUSTS)

LAMPHOLDER

CABLE ENTRY WITH EMERGENCY
CABLE GLAND
UNIT

AUTONOMY

DETAIL

FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50Hz
			

T6 	

T 85°C

EVSN118EL	

T5	

T100°C	

T4	

T135°C		

1 x 18W	

			
			

T6	
T5	

T100°C	

1 x PG 13,5	

-	

-	

A

1 x PG 13,5	

-	

-	

A		

T 85°C

EVSN136EL	

G13	

1 x 36W	

G1	

			

T4	

T135°C						

EVSN158EL	

T5	

T100°C 	

			

T6	

T 85°C 							

EVSN218EL	

T5 	

T100°C 	

T4	

T135°C	

1 x 58W	
2 x 18W	

			
			

T6	
T5 	

T100°C 	

1 x PG 13,5	

2 x 36W	

-	

-	

-	

A

G13	

1 x PG 13,5	

G13 	

1 x PG 13,5	

-	

-	

A

G13	

1 x PG 13,5	

-	

-	

A

T 85°C

EVSN236EL	

G13	

-	

A

					

			

T4	

T135°C

EVSN258EL	

T5	

T100°C 	

2 x 58W	

EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50Hz
			

T6	

T 85°C

EVSNE118EL	

T5	

T100°C	

T4	

T135°C

1 x 18W	

			

		

			

T6 	
T5	

4,8V - 4Ah	

3h	

B

G13	

1 x PG 13,5	

4,8V - 4Ah	

3h	

B	

G13	

1 x PG 13,5	

4,8V - 4Ah	

3h	

B

G13	

T100°C	

1 x PG 13,5	

1 x PG 13,5	

4,8V - 4Ah	

3h	

B

1 x PG 13,5	

4,8V - 4Ah	

3h	

B		

G13	

1 x PG 13,5	

4,8V - 4Ah	

3h	

B

D [mm]

WEIGHT [Kg]

T 85°C

EVSNE136EL	

G13	

1 x 36W	

			

T4	

T135°C

EVSNE158EL	

T5	

T100°C 	

1 x 58W	

			

T6	

T 85°C

EVSNE218EL	

T5	

T100°C	

			

T4	

T135°C

			

T6	

T 85°C

EVSNE236EL	

T5	

T100°C	

	

2 x 18W	

2 x 36W 	

		

		

G13

T4	

T135°C		

T5	

EVSNE258EL	 2 x 58W	

T100°C 	

	

EVSN Technical features
CODE

A [mm]

B [mm]

C [mm]

CABLE ENTRY

DETAIL

EVSN118EL	

667	

90	

98	

420	

1,75	

1 x PG 13,5	

A

EVSN136EL	

1276	

90	

98	

775	

2,45	

1 x PG 13,5	

A

EVSN158EL	

1576	

90	

98	

1070	

3,10	

1 x PG 13,5	

A

EVSN218EL	

667	

155	

102	

455	

2,10	

1 x PG 13,5	

A

EVSN236EL	

1276	

155	

102	

770	

3,90	

1 x PG 13,5	

A

EVSN258EL	

1576	

155	

102	

1055	

5,20	

1 x PG 13,5	

A

Reference details
D

C

A

A

B

Since 1961

50 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
Ex Lighting

EVSN Technical features
CODE

B [mm]

C [mm]

842	

90	

120	

EVSNE136EL	

1451	

90	

EVSNE158EL	

1751	

90	

EVSNE218EL	

842	

EVSNE236EL	
EVSNE258EL	

D [mm]

WEIGHT [Kg]

CABLE ENTRY

DETAIL

420	

2,75	

1 x PG 13,5	

B

120	

775	

3,45	

1 x PG 13,5	

B

120	

1070	

4,10	

1 x PG 13,5	

B

155	

120	

455	

3,10	

1 x PG 13,5	

B

1451	

155	

120	

770	

4,90	

1 x PG 13,5	

B

1751	

155	

120	

1055	

6,20	

1 x PG 13,5	

B

Reference details

B

C

D

A

B

EVSN Installation and mounting details
Ceiling mounting

Pendant mounting

type 1

type 2

Wall/structure mounting

type 3

0
10

type 4

Pole mounting
Assemblig detail with pole (typical)

50

100

45°

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 51

EVSN

A [mm]

EVSNE118EL
Ex Lighting 	

EVSN Polar diagrams – photometric data
EVS136

EVS158

EVS218

EVS236

EVS258

EVSN

EVS118

EVSN On request accessories
CODE

DESCRIPTION

INSTALLATION

MATERIAL

20302.0122	

POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE	

TYPE 4	

GALVANIZED STEEL

20302.0123	

POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE	

TYPE 4	

GALVANIZED STEEL

20302.0125	

POLE MOUNTING KIT (SIZE 1” DIA.) C/W HARDWARE	

TYPE 4	

GALVANIZED STEEL

20301.0165	

PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS	

TYPE 2	

STAINLESS STEEL

20303.0091	

CEILING MOUNTING KIT C/W HARDWARE	

TYPE 1	

GALVANIZED STEEL

20303.0092	

WALL/STRUCTURE MOUNTING KIT C/W HARDWARE	

TYPE 3	

GALVANIZED STEEL

REMARK:

Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.
Since 1961

52 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
FLOODLIGHTS
FOR DISCHARGE LAMPS

Explosion Proof Electrical Equipment

Installation: hazardous areas - Zone 2 (Gases) - Zone 22 (Dusts)
Classification: Group II - Category 3G 3D

SFDN

FLOODLIGHT
ATEX 94/9/EC
II 3 G Ex nR II T3
II 3 D Ex tD A22 T200°C

EXECUTION
AMBIENT TEMPERATURE

-20°C ÷ +60°C

PROTECTION DEGREE

IP66

CERTIFICATE REF.

IMQ 08 ATEX 019

RULES OF COMPLIANCE

EN 60079-0; EN 60079-15; EN 61241-0; 61241-1

Mechanical characteristics
Body	

marine grade copper free aluminum

Diffuser	

tempered front glass

Support	

steel bracket with rotation-proof system

Reflector	

anodized and polished 99,85 pure aluminum internal optic

Painting	

thermosetting polyester powder resistant to atmospheric agents and corrosion grey RAL 9006 colour

Screws	

stainless steel

Gaskets	

pure silicon heat resistance

Cable entry	

complete with cable gland

Internal optic	

(S) symmetric optic - (A)asymmetric optic - (C) concentrating beam optic

Electrical characteristics
Power supply	

conventional ballast 230V - 50Hz (P.F. CORRECTED - cos ρ ≥ 0,95)

Lampholders	

porcellain E40 / E27 size

Internal wiring	

high-temperature resistant silicon rubber insulation cables

Terminals	

suitable up to 4mm/sq cables

On Request Accessories:
• Control gear with voltage supply different than standard
• Threaded cable entry different than standard
Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 53

SFDN

Ex Lighting
Ex Lighting

SFDN

SFDN Technical data
CODE

LAMP

TEMPERATURE CLASS
(GAS)

TEMPERATURE CLASS
(DUSTS)

LAMPHOLDER
SIZE

CABLE ENTRY WITH
CABLE GLAND

DETAIL

FLOODLIGHT FOR HIGH PRESSURE MERCURY VAPOUR LAMP - POWER SUPPLY 230V 50Hz
SFDN#250HG-(1)	

250 W 	

T3 (Ta = -20°C / +60°C)	

T 200°C	

E-40	

1 x PCE M20	

A

SFDN#400HG-(1)	

400 W	

T3 (Ta = -20°C / +60°C)	

T 200°C	

E-40	

1 x PCE M20	

A

FLOODLIGHT FOR METAL HALIDE LAMP - POWER SUPPLY 230V 50Hz
SFDN#150MH-(1)	

150 W	

T3 (Ta = -20°C / +60°C)	

T 200°C	

E-27	

1 x PCE M20	

A

SFDN#250MH-(1)	

250 W 	

T3 (Ta = -20°C / +60°C)	

T 200°C	

E-40	

1 x PCE M20	

A

SFDN#400MH-(1)	

400 W	

T3 (Ta = -20°C / +60°C)	

T 200°C	

E-40	

1 x PCE M20	

A

FLOODLIGHT FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V 50Hz
SFDN#150HPNA-(1)	

150 W	

T3 (Ta = -20°C / +60°C)	

T 200°C	

E-40	

1 x PCE M20	

A

SFDN#250HPNA-(1)	

250 W 	

T3 (Ta = -20°C / +60°C)	

T 200°C	

E-40	

1 x PCE M20	

A

SFDN#400HPNA-(1)	

400 W	

T3 (Ta = -20°C / +60°C)	

T 200°C	

E-40	

1 x PCE M20	

A

(1) INTERNAL OPTICAL BEAM: (S) SYMMETRIC BEAM - (A) ASYMMETRIC BEAM - (C) CONCENTRATING BEAM			
SAMPLE: SFDN#400MH-S = FLOODLIGHT 400W METAL HALIDE WITH SYMMETRIC OPTICAL BEAM 			

SFDN Technical features
CODE

A [mm]

B [mm]

C [mm]

D [mm]

WEIGHT [Kg]

CABLE ENTRY

DETAIL

SFDN#250HG-(1)	

544	

461	

430	

180	

8,80	

1 x PCE M20	

A

SFDN#400HG-(1)	

544	

461	

430	

180	

9,10	

1 x PCE M20	

A

SFDN#150MH-(1)	

544	

461	

430	

180	

9,50	

1 x PCE M20	

A

SFDN#250MH-(1)	

544	

461	

430	

180	

9,70	

1 x PCE M20	

A

SFDN#400MH-(1)	

544	

461	

430	

180	

11,00	

1 x PCE M20	

A

SFDN#150HPNA-(1)	

544	

461	

430	

180	

10,50	

1 x PCE M20	

A

SFDN#250HPNA-(1)	

544	

461	

430	

180	

11,10	

1 x PCE M20	

A

SFDN#400HPNA-(1)	

544	

461	

430	

180	

12,30	

1 x PCE M20	

A

(1) INTERNAL OPTICAL BEAM: (S) SYMMETRIC BEAM - (A) ASYMMETRIC BEAM - (C) CONCENTRATING BEAM				
SAMPLE: SFDN#400MH-S = FLOODLIGHT 400W METAL HALIDE WITH SYMMETRIC OPTICAL BEAM 					
	

Since 1961

54 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
Ex Lighting

Reference details

A
D

C

www.feam-ex.com

FLOODLIGHT TYPE

SFDN

150W HPNA
250W HPNA
400W HPNA
230V 50Hz
240V 50HZ

SM
AS
CT

150W MH
250W MH
400W MH
220V 60Hz
277 60Hz

B

0.206m˛

IK10

Ex nR II T3
Ex tD A22 IP 66 T200°C

A

II 3 GD

IMQ 09 ATEX 019
Tamb -20° C / +60° C

TOGLIERE TENSIONE PRIMA DI APRIRE
DO NOT OPEN WHILE ENERGIZED

0°
12

155

155

SFDN Polar diagrams – photometric data
SFDN#250HPNA-S

SFDN#250HPNA-A

SFDN#250HPNA-C

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 55

SFDN

SFDN Technical features
Ex Lighting

SFDN

SFDN Polar diagrams – photometric data
SFDN#400MH-S

SFDN#400MH-A

SFDN#400MH-C

SFDN On request accessories
CODE

DESCRIPTION

20303.0099	

PROTECTION GRID	

20303.0100	

MATERIAL

POLE ADAPTER FOR DIA 40÷60MM	

Protection grid

20303.0099

ALUMINIUM
PAINTED STEEL

Pole adapter

20303.0100

REMARK:

Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.

Since 1961

56 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
Explosion Proof Electrical Equipment

Weatherproof Lighting

EVSA

Installation: Safe Area
Insulation Class: I

LIGHTING FIXTURE
CEI / EN
EXECUTION

INDUSTRIAL WEATHERPROOF

AMBIENT TEMPERATURE

-

PROTECTION DEGREE

IP65

CERTIFICATE REF.

-

RULES OF COMPLIANCE

EN 60598-1 + A1; EN 60598-2-1

Mechanical characteristics	
Body	

glass fibre reinforced polyester resin

Diffuser	

U/V resistant polycarbonate - hinged to body

Safety closing	

stainless steel hooks

Gaskets	

EPDM 60 rubber suitable for high temperatures and resistant to enviroments conditions

Internal reflector	

white stove enamelled sheet steel

Cable entry	

complete with PVC cable gland

Electrical characteristics
Power supply	

dual channel electronic ballast 220/240V 50/60Hz (cos ρ ≥ 0,98)

Lampholders	

bi-pin G13 cap

Terminals	

suitable up to 6mm/sq cables

On Request Accessories:
• Pole mounting kit complete with stainless steel hardware
• Ceiling mounting kit complete with stainless steel hardware
• Pendant mounting kit complete with stainless steel hardware

• Wall/Structure mounting kit complete with stainless steel hardware
• Electronic ballast with voltage supply different than standard
• Emergency Group

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 57

EVSA

WEATHERPROOF FLUORESCENT
LIGHTING FIXTURES
Weatherproof Lighting

EVSA Technical data
EVSA

CODE

TEMPERATURE CLASS
(GAS)

LAMP

TEMPERATURE CLASS
(DUSTS)

LAMPHOLDER

CABLE ENTRY
WITH CABLE
GLAND

EMERGENCY
UNIT

AUTONOMY

DETAIL

FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50Hz
EVSA118EL	

1 x 18W	

-	

-	

G13	

1 x PG 13,5	

-	

-	

A

EVSA136EL	

1 x 36W	

-	

-	

G13	

1 x PG 13,5	

-	

-	

A

EVSA158EL	

1 x 58W	

-	

-	

G13	

1 x PG 13,5	

-	

-	

A

EVSA218EL	

2 x 18W	

-	

-	

G13	

1 x PG 13,5	

-	

-	

A

EVSA236EL	

2 x 36W	

-	

-	

G13	

1 x PG 13,5	

-	

-	

A

EVSA258EL	

2 x 58W	

-	

-	

G13	

1 x PG 13,5	

-	

-	

A

EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50Hz
EVSA118EL-E	

1 x 18W	

-	

-	

G13	

1 x PG 13,5	

4,8V - 4Ah	

3h	

A

EVSA136EL-E	

1 x 36W	

-	

-	

G13	

1 x PG 13,5	

4,8V - 4Ah	

3h	

A

EVSA158EL-E	

1 x 58W	

-	

-	

G13	

1 x PG 13,5	

4,8V - 4Ah	

3h	

A

EVSA218EL-E	

2 x 18W	

-	

-	

G13	

1 x PG 13,5	

4,8V - 4Ah	

3h	

A

EVSA236EL-E	

2 x 36W	

-	

-	

G13	

1 x PG 13,5	

4,8V - 4Ah	

3h	

A

EVSA258EL-E	

2 x 58W	

-	

-	

G13	

1 x PG 13,5	

4,8V - 4Ah	

3h	

A

EVSA Technical features
CODE

A [mm]

B [mm]

C [mm]

D [mm]

WEIGHT [Kg]

CABLE ENTRY

DETAIL

EVSA118EL	

667	

90	

98	

420	

1,75	

1 x PG 13,5	

A

EVSA136EL	

1276	

90	

98	

775	

2,45	

1 x PG 13,5	

A

EVSA158EL	

1576	

90	

98	

1070	

3,10	

1 x PG 13,5	

A

EVSA218EL	

667	

155	

102	

455	

2,10	

1 x PG 13,5	

A

EVSA236EL	

1276	

155	

102	

770	

3,90	

1 x PG 13,5	

A

EVSA258EL	

1576	

155	

102	

1055	

5,20	

1 x PG 13,5	

A

A [mm]

B [mm]

C [mm]

D [mm]

CODE
EVSA118EL-E	

667	

90	

98	

WEIGHT [Kg]

CABLE ENTRY

DETAIL

420	

1,75	

1 x PG 13,5	

A

EVSA136EL-E	

1276	

90	

98	

775	

2,45	

1 x PG 13,5	

A

EVSA158EL-E	

1576	

90	

98	

1070	

3,10	

1 x PG 13,5	

A

EVSA218EL-E	

667	

155	

102	

455	

2,10	

1 x PG 13,5	

A

EVSA236EL-E	

1276	

155	

102	

770	

3,90	

1 x PG 13,5	

A

EVSA258EL-E	

1576	

155	

102	

1055	

5,20	

1 x PG 13,5	

A

Reference details

A

C

D

A

B

Since 1961

58 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
Weatherproof Lighting

EVSA Installation and mounting details
Ceiling mounting

Pendant mounting

type 2

Wall/structure mounting

type 3

type 4

00

EVSA

type 1

Pole mounting
Assemblig detail with pole (typical)

1

50

100

45°

EVSA Polar diagrams – photometric data
EVS118

EVS136

EVS158

Since 1961

YOUR PARTNER FOR SAFETY

Feam Catalogue 01 - 59
Weatherproof Lighting

EVSA Polar diagrams – photometric data
EVS236

EVSA

EVS218

EVS258

EVSA On request accessories
CODE

DESCRIPTION

INSTALLATION

MATERIAL

20302.0122	

POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE	

TYPE 4	

GALVANIZED STEEL

20302.0123	

POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE	

TYPE 4	

GALVANIZED STEEL

20302.0125	

POLE MOUNTING KIT (SIZE 1” DIA.) C/W HARDWARE	

TYPE 4	

GALVANIZED STEEL

20301.0165	

PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS	

TYPE 2	

STAINLESS STEEL

20303.0091	

CEILING MOUNTING KIT C/W HARDWARE	

TYPE 1	

GALVANIZED STEEL

20303.0092	

WALL/STRUCTURE MOUNTING KIT C/W HARDWARE	

TYPE 3	

GALVANIZED STEEL

REMARK:

Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.

Since 1961

60 - Feam Catalogue 01

YOUR PARTNER FOR SAFETY
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting

More Related Content

What's hot

Religious architecture of china
Religious architecture of chinaReligious architecture of china
Religious architecture of chinabenazirmohamedkhan
 
HISTORY: Cambodian Architecture 1.0
HISTORY: Cambodian Architecture 1.0HISTORY: Cambodian Architecture 1.0
HISTORY: Cambodian Architecture 1.0ArchiEducPH
 
Module 4- Gothic Architecture | KTU | Semester 4 | History of Architecture
Module 4- Gothic Architecture | KTU | Semester 4 | History of Architecture Module 4- Gothic Architecture | KTU | Semester 4 | History of Architecture
Module 4- Gothic Architecture | KTU | Semester 4 | History of Architecture Gary Gilson
 
Islamic Architecture
Islamic ArchitectureIslamic Architecture
Islamic ArchitectureMark Togado
 
Korea ppt-korean architecture
Korea ppt-korean architectureKorea ppt-korean architecture
Korea ppt-korean architectureJini Shim
 
Early christian architecture
Early christian architectureEarly christian architecture
Early christian architectureGoby Cracked
 
Ancon Wall Ties and Restraint Fixings for Brick, Block and Stone
Ancon Wall Ties and Restraint Fixings for Brick, Block and StoneAncon Wall Ties and Restraint Fixings for Brick, Block and Stone
Ancon Wall Ties and Restraint Fixings for Brick, Block and StoneLBS Builders Merchants
 
HISTORY: Korean & Japanese Architecture 1.0
HISTORY: Korean & Japanese Architecture 1.0HISTORY: Korean & Japanese Architecture 1.0
HISTORY: Korean & Japanese Architecture 1.0ArchiEducPH
 
HISTORY: Korean Architecture 1.0
HISTORY: Korean Architecture 1.0HISTORY: Korean Architecture 1.0
HISTORY: Korean Architecture 1.0ArchiEducPH
 
Logbook application
Logbook applicationLogbook application
Logbook applicationRey Gabitan
 
Celebrity - imagens tour - Neves (27) 8825-2138
Celebrity - imagens tour - Neves (27) 8825-2138Celebrity - imagens tour - Neves (27) 8825-2138
Celebrity - imagens tour - Neves (27) 8825-2138Neves Corretor
 
Japan architecture in a nutt shell
Japan architecture in a nutt shellJapan architecture in a nutt shell
Japan architecture in a nutt shellSaad Dahleh
 
Chinese Civilization and Architecture
Chinese Civilization and ArchitectureChinese Civilization and Architecture
Chinese Civilization and ArchitectureNafis Nirman
 
2012 ctbuh outrigger_guide_preview
2012 ctbuh outrigger_guide_preview2012 ctbuh outrigger_guide_preview
2012 ctbuh outrigger_guide_previewSyed Raziuddin
 

What's hot (17)

Religious architecture of china
Religious architecture of chinaReligious architecture of china
Religious architecture of china
 
HISTORY: Cambodian Architecture 1.0
HISTORY: Cambodian Architecture 1.0HISTORY: Cambodian Architecture 1.0
HISTORY: Cambodian Architecture 1.0
 
Module 4- Gothic Architecture | KTU | Semester 4 | History of Architecture
Module 4- Gothic Architecture | KTU | Semester 4 | History of Architecture Module 4- Gothic Architecture | KTU | Semester 4 | History of Architecture
Module 4- Gothic Architecture | KTU | Semester 4 | History of Architecture
 
Islamic Architecture
Islamic ArchitectureIslamic Architecture
Islamic Architecture
 
Korea ppt-korean architecture
Korea ppt-korean architectureKorea ppt-korean architecture
Korea ppt-korean architecture
 
Early christian architecture
Early christian architectureEarly christian architecture
Early christian architecture
 
Ancon Wall Ties and Restraint Fixings for Brick, Block and Stone
Ancon Wall Ties and Restraint Fixings for Brick, Block and StoneAncon Wall Ties and Restraint Fixings for Brick, Block and Stone
Ancon Wall Ties and Restraint Fixings for Brick, Block and Stone
 
Aldar Headqaurter
Aldar Headqaurter  Aldar Headqaurter
Aldar Headqaurter
 
HISTORY: Korean & Japanese Architecture 1.0
HISTORY: Korean & Japanese Architecture 1.0HISTORY: Korean & Japanese Architecture 1.0
HISTORY: Korean & Japanese Architecture 1.0
 
HISTORY: Korean Architecture 1.0
HISTORY: Korean Architecture 1.0HISTORY: Korean Architecture 1.0
HISTORY: Korean Architecture 1.0
 
Logbook application
Logbook applicationLogbook application
Logbook application
 
High Rise Makka Clock Tower
High Rise Makka Clock TowerHigh Rise Makka Clock Tower
High Rise Makka Clock Tower
 
Confu, dao & buddhism
Confu, dao & buddhismConfu, dao & buddhism
Confu, dao & buddhism
 
Celebrity - imagens tour - Neves (27) 8825-2138
Celebrity - imagens tour - Neves (27) 8825-2138Celebrity - imagens tour - Neves (27) 8825-2138
Celebrity - imagens tour - Neves (27) 8825-2138
 
Japan architecture in a nutt shell
Japan architecture in a nutt shellJapan architecture in a nutt shell
Japan architecture in a nutt shell
 
Chinese Civilization and Architecture
Chinese Civilization and ArchitectureChinese Civilization and Architecture
Chinese Civilization and Architecture
 
2012 ctbuh outrigger_guide_preview
2012 ctbuh outrigger_guide_preview2012 ctbuh outrigger_guide_preview
2012 ctbuh outrigger_guide_preview
 

Viewers also liked

Feam EJB INX Zone 1 & Zone 2 Enclosures (Atex) Hazardous Area
Feam EJB INX Zone 1 & Zone 2 Enclosures (Atex) Hazardous AreaFeam EJB INX Zone 1 & Zone 2 Enclosures (Atex) Hazardous Area
Feam EJB INX Zone 1 & Zone 2 Enclosures (Atex) Hazardous AreaThorne & Derrick International
 
FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...
FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...
FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...Thorne & Derrick International
 
02 custodie eng
02 custodie eng02 custodie eng
02 custodie engHai Pham
 
01 illuminazione eng
01 illuminazione eng01 illuminazione eng
01 illuminazione engHai Pham
 
Marechal DX ATEX Plugs & Sockets - Marechal DX Metal Decontactor For Hazardou...
Marechal DX ATEX Plugs & Sockets - Marechal DX Metal Decontactor For Hazardou...Marechal DX ATEX Plugs & Sockets - Marechal DX Metal Decontactor For Hazardou...
Marechal DX ATEX Plugs & Sockets - Marechal DX Metal Decontactor For Hazardou...Thorne & Derrick International
 
Zone 2 Hazardous Area Lighting (ATEX) - Explosion Proof Lighting - Petrel DN ...
Zone 2 Hazardous Area Lighting (ATEX) - Explosion Proof Lighting - Petrel DN ...Zone 2 Hazardous Area Lighting (ATEX) - Explosion Proof Lighting - Petrel DN ...
Zone 2 Hazardous Area Lighting (ATEX) - Explosion Proof Lighting - Petrel DN ...Thorne & Derrick International
 
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood LightZone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood LightThorne & Derrick International
 
Salisbury Electrical Safety Equipment - Dielectric Footwear, Rubber Insulatin...
Salisbury Electrical Safety Equipment - Dielectric Footwear, Rubber Insulatin...Salisbury Electrical Safety Equipment - Dielectric Footwear, Rubber Insulatin...
Salisbury Electrical Safety Equipment - Dielectric Footwear, Rubber Insulatin...Thorne & Derrick International
 
Hadar Lighting - Hazardous Area Zone 1 & Zone 2 Lighting (ATEX Certified)
Hadar Lighting - Hazardous Area Zone 1 & Zone 2 Lighting (ATEX Certified)Hadar Lighting - Hazardous Area Zone 1 & Zone 2 Lighting (ATEX Certified)
Hadar Lighting - Hazardous Area Zone 1 & Zone 2 Lighting (ATEX Certified)Thorne & Derrick International
 
05 multiple control stations
05 multiple control stations05 multiple control stations
05 multiple control stationsHai Pham
 
CATU Insulating Rubber Gloves - Rubber Latex Gloves, Composite Gloves & Arc F...
CATU Insulating Rubber Gloves - Rubber Latex Gloves, Composite Gloves & Arc F...CATU Insulating Rubber Gloves - Rubber Latex Gloves, Composite Gloves & Arc F...
CATU Insulating Rubber Gloves - Rubber Latex Gloves, Composite Gloves & Arc F...Thorne & Derrick International
 
Catu Electrical - Low & High Voltage Electrical Safety Equipment For Undergro...
Catu Electrical - Low & High Voltage Electrical Safety Equipment For Undergro...Catu Electrical - Low & High Voltage Electrical Safety Equipment For Undergro...
Catu Electrical - Low & High Voltage Electrical Safety Equipment For Undergro...Thorne & Derrick International
 

Viewers also liked (12)

Feam EJB INX Zone 1 & Zone 2 Enclosures (Atex) Hazardous Area
Feam EJB INX Zone 1 & Zone 2 Enclosures (Atex) Hazardous AreaFeam EJB INX Zone 1 & Zone 2 Enclosures (Atex) Hazardous Area
Feam EJB INX Zone 1 & Zone 2 Enclosures (Atex) Hazardous Area
 
FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...
FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...
FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...
 
02 custodie eng
02 custodie eng02 custodie eng
02 custodie eng
 
01 illuminazione eng
01 illuminazione eng01 illuminazione eng
01 illuminazione eng
 
Marechal DX ATEX Plugs & Sockets - Marechal DX Metal Decontactor For Hazardou...
Marechal DX ATEX Plugs & Sockets - Marechal DX Metal Decontactor For Hazardou...Marechal DX ATEX Plugs & Sockets - Marechal DX Metal Decontactor For Hazardou...
Marechal DX ATEX Plugs & Sockets - Marechal DX Metal Decontactor For Hazardou...
 
Zone 2 Hazardous Area Lighting (ATEX) - Explosion Proof Lighting - Petrel DN ...
Zone 2 Hazardous Area Lighting (ATEX) - Explosion Proof Lighting - Petrel DN ...Zone 2 Hazardous Area Lighting (ATEX) - Explosion Proof Lighting - Petrel DN ...
Zone 2 Hazardous Area Lighting (ATEX) - Explosion Proof Lighting - Petrel DN ...
 
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood LightZone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
 
Salisbury Electrical Safety Equipment - Dielectric Footwear, Rubber Insulatin...
Salisbury Electrical Safety Equipment - Dielectric Footwear, Rubber Insulatin...Salisbury Electrical Safety Equipment - Dielectric Footwear, Rubber Insulatin...
Salisbury Electrical Safety Equipment - Dielectric Footwear, Rubber Insulatin...
 
Hadar Lighting - Hazardous Area Zone 1 & Zone 2 Lighting (ATEX Certified)
Hadar Lighting - Hazardous Area Zone 1 & Zone 2 Lighting (ATEX Certified)Hadar Lighting - Hazardous Area Zone 1 & Zone 2 Lighting (ATEX Certified)
Hadar Lighting - Hazardous Area Zone 1 & Zone 2 Lighting (ATEX Certified)
 
05 multiple control stations
05 multiple control stations05 multiple control stations
05 multiple control stations
 
CATU Insulating Rubber Gloves - Rubber Latex Gloves, Composite Gloves & Arc F...
CATU Insulating Rubber Gloves - Rubber Latex Gloves, Composite Gloves & Arc F...CATU Insulating Rubber Gloves - Rubber Latex Gloves, Composite Gloves & Arc F...
CATU Insulating Rubber Gloves - Rubber Latex Gloves, Composite Gloves & Arc F...
 
Catu Electrical - Low & High Voltage Electrical Safety Equipment For Undergro...
Catu Electrical - Low & High Voltage Electrical Safety Equipment For Undergro...Catu Electrical - Low & High Voltage Electrical Safety Equipment For Undergro...
Catu Electrical - Low & High Voltage Electrical Safety Equipment For Undergro...
 

Similar to FEAM Lighting - Hazardous Area & Explosion Proof Lighting

01 feam lighting_eng
01 feam lighting_eng01 feam lighting_eng
01 feam lighting_engHai Pham
 
ASCO ATEX Solenoid Valves - 327 Series - Spec Sheet
ASCO ATEX Solenoid Valves - 327 Series - Spec SheetASCO ATEX Solenoid Valves - 327 Series - Spec Sheet
ASCO ATEX Solenoid Valves - 327 Series - Spec SheetThorne & Derrick UK
 
02 feam enclosures_eng
02 feam enclosures_eng02 feam enclosures_eng
02 feam enclosures_engHai Pham
 
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous AreaStahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous AreaThorne & Derrick International
 
03 feam%20 cable%20glands_eng
03 feam%20 cable%20glands_eng03 feam%20 cable%20glands_eng
03 feam%20 cable%20glands_engHai Pham
 
06 pinze di-terra-eng
06 pinze di-terra-eng06 pinze di-terra-eng
06 pinze di-terra-engHai Pham
 
Stahl 6149 LED Hand Lamp With Mains Connection - ATEX Zone 1 Zone 2 Hazardous...
Stahl 6149 LED Hand Lamp With Mains Connection - ATEX Zone 1 Zone 2 Hazardous...Stahl 6149 LED Hand Lamp With Mains Connection - ATEX Zone 1 Zone 2 Hazardous...
Stahl 6149 LED Hand Lamp With Mains Connection - ATEX Zone 1 Zone 2 Hazardous...Thorne & Derrick International
 
05 pulsantiere prese-spine-eng
05 pulsantiere prese-spine-eng05 pulsantiere prese-spine-eng
05 pulsantiere prese-spine-engHai Pham
 
Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1...
Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1...Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1...
Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1...Thorne & Derrick International
 
Stahl YA90 Sounder Signalling Device – ATEX Zone 1 Zone 2 Hazardous Area Sign...
Stahl YA90 Sounder Signalling Device – ATEX Zone 1 Zone 2 Hazardous Area Sign...Stahl YA90 Sounder Signalling Device – ATEX Zone 1 Zone 2 Hazardous Area Sign...
Stahl YA90 Sounder Signalling Device – ATEX Zone 1 Zone 2 Hazardous Area Sign...Thorne & Derrick International
 
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingThorne & Derrick International
 
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingThorne & Derrick International
 
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingThorne & Derrick International
 
Floodlights Zone 1 & Zone 2 (ATEX) - Hadar Hazardous Area Lighting
Floodlights Zone 1 & Zone 2 (ATEX) - Hadar Hazardous Area LightingFloodlights Zone 1 & Zone 2 (ATEX) - Hadar Hazardous Area Lighting
Floodlights Zone 1 & Zone 2 (ATEX) - Hadar Hazardous Area LightingThorne & Derrick International
 
Stahl 6521_4 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6521_4 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6521_4 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6521_4 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingThorne & Derrick International
 
Switchtec Din Rail Terminal Brochure
Switchtec Din Rail Terminal BrochureSwitchtec Din Rail Terminal Brochure
Switchtec Din Rail Terminal BrochureAndy Birdsall
 
Marechal DN Robust Decontactor - Industrial Plugs & Sockets
Marechal DN Robust Decontactor - Industrial Plugs & SocketsMarechal DN Robust Decontactor - Industrial Plugs & Sockets
Marechal DN Robust Decontactor - Industrial Plugs & SocketsThorne & Derrick International
 
Wolf Safety Lamp - Zone 1 Hazardous Area Tank Lighting Kit (ATEX Certified)
Wolf Safety Lamp - Zone 1 Hazardous Area Tank Lighting Kit (ATEX Certified)Wolf Safety Lamp - Zone 1 Hazardous Area Tank Lighting Kit (ATEX Certified)
Wolf Safety Lamp - Zone 1 Hazardous Area Tank Lighting Kit (ATEX Certified)Thorne & Derrick International
 
Stahl 8220 Star Delta Motor Starters – ATEX Zone 1 Zone 2 Hazardous Area
Stahl 8220 Star Delta Motor Starters – ATEX Zone 1 Zone 2 Hazardous Area Stahl 8220 Star Delta Motor Starters – ATEX Zone 1 Zone 2 Hazardous Area
Stahl 8220 Star Delta Motor Starters – ATEX Zone 1 Zone 2 Hazardous Area Thorne & Derrick International
 
Stahl 8220 Star Reversing Starter Motor Starters - ATEX Zone 1 Zone 2 Hazardo...
Stahl 8220 Star Reversing Starter Motor Starters - ATEX Zone 1 Zone 2 Hazardo...Stahl 8220 Star Reversing Starter Motor Starters - ATEX Zone 1 Zone 2 Hazardo...
Stahl 8220 Star Reversing Starter Motor Starters - ATEX Zone 1 Zone 2 Hazardo...Thorne & Derrick International
 

Similar to FEAM Lighting - Hazardous Area & Explosion Proof Lighting (20)

01 feam lighting_eng
01 feam lighting_eng01 feam lighting_eng
01 feam lighting_eng
 
ASCO ATEX Solenoid Valves - 327 Series - Spec Sheet
ASCO ATEX Solenoid Valves - 327 Series - Spec SheetASCO ATEX Solenoid Valves - 327 Series - Spec Sheet
ASCO ATEX Solenoid Valves - 327 Series - Spec Sheet
 
02 feam enclosures_eng
02 feam enclosures_eng02 feam enclosures_eng
02 feam enclosures_eng
 
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous AreaStahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
 
03 feam%20 cable%20glands_eng
03 feam%20 cable%20glands_eng03 feam%20 cable%20glands_eng
03 feam%20 cable%20glands_eng
 
06 pinze di-terra-eng
06 pinze di-terra-eng06 pinze di-terra-eng
06 pinze di-terra-eng
 
Stahl 6149 LED Hand Lamp With Mains Connection - ATEX Zone 1 Zone 2 Hazardous...
Stahl 6149 LED Hand Lamp With Mains Connection - ATEX Zone 1 Zone 2 Hazardous...Stahl 6149 LED Hand Lamp With Mains Connection - ATEX Zone 1 Zone 2 Hazardous...
Stahl 6149 LED Hand Lamp With Mains Connection - ATEX Zone 1 Zone 2 Hazardous...
 
05 pulsantiere prese-spine-eng
05 pulsantiere prese-spine-eng05 pulsantiere prese-spine-eng
05 pulsantiere prese-spine-eng
 
Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1...
Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1...Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1...
Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1...
 
Stahl YA90 Sounder Signalling Device – ATEX Zone 1 Zone 2 Hazardous Area Sign...
Stahl YA90 Sounder Signalling Device – ATEX Zone 1 Zone 2 Hazardous Area Sign...Stahl YA90 Sounder Signalling Device – ATEX Zone 1 Zone 2 Hazardous Area Sign...
Stahl YA90 Sounder Signalling Device – ATEX Zone 1 Zone 2 Hazardous Area Sign...
 
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
 
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
 
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
 
Floodlights Zone 1 & Zone 2 (ATEX) - Hadar Hazardous Area Lighting
Floodlights Zone 1 & Zone 2 (ATEX) - Hadar Hazardous Area LightingFloodlights Zone 1 & Zone 2 (ATEX) - Hadar Hazardous Area Lighting
Floodlights Zone 1 & Zone 2 (ATEX) - Hadar Hazardous Area Lighting
 
Stahl 6521_4 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6521_4 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6521_4 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6521_4 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
 
Switchtec Din Rail Terminal Brochure
Switchtec Din Rail Terminal BrochureSwitchtec Din Rail Terminal Brochure
Switchtec Din Rail Terminal Brochure
 
Marechal DN Robust Decontactor - Industrial Plugs & Sockets
Marechal DN Robust Decontactor - Industrial Plugs & SocketsMarechal DN Robust Decontactor - Industrial Plugs & Sockets
Marechal DN Robust Decontactor - Industrial Plugs & Sockets
 
Wolf Safety Lamp - Zone 1 Hazardous Area Tank Lighting Kit (ATEX Certified)
Wolf Safety Lamp - Zone 1 Hazardous Area Tank Lighting Kit (ATEX Certified)Wolf Safety Lamp - Zone 1 Hazardous Area Tank Lighting Kit (ATEX Certified)
Wolf Safety Lamp - Zone 1 Hazardous Area Tank Lighting Kit (ATEX Certified)
 
Stahl 8220 Star Delta Motor Starters – ATEX Zone 1 Zone 2 Hazardous Area
Stahl 8220 Star Delta Motor Starters – ATEX Zone 1 Zone 2 Hazardous Area Stahl 8220 Star Delta Motor Starters – ATEX Zone 1 Zone 2 Hazardous Area
Stahl 8220 Star Delta Motor Starters – ATEX Zone 1 Zone 2 Hazardous Area
 
Stahl 8220 Star Reversing Starter Motor Starters - ATEX Zone 1 Zone 2 Hazardo...
Stahl 8220 Star Reversing Starter Motor Starters - ATEX Zone 1 Zone 2 Hazardo...Stahl 8220 Star Reversing Starter Motor Starters - ATEX Zone 1 Zone 2 Hazardo...
Stahl 8220 Star Reversing Starter Motor Starters - ATEX Zone 1 Zone 2 Hazardo...
 

More from Thorne & Derrick International

Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Thorne & Derrick International
 
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptTHORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptThorne & Derrick International
 
The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018Thorne & Derrick International
 
3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick InternationalThorne & Derrick International
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-AThorne & Derrick International
 
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...Thorne & Derrick International
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Thorne & Derrick International
 
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RowePepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RoweThorne & Derrick International
 
Ultrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandUltrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandThorne & Derrick International
 
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DSIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DThorne & Derrick International
 
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...Thorne & Derrick International
 
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetFiloform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetThorne & Derrick International
 

More from Thorne & Derrick International (20)

Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...
 
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptTHORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
 
The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018
 
3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International
 
CATU Electrical Safety Catalogue
CATU Electrical Safety CatalogueCATU Electrical Safety Catalogue
CATU Electrical Safety Catalogue
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
 
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
 
Roxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional DrawingRoxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional Drawing
 
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RowePepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
 
T&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive AtmospheresT&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive Atmospheres
 
Ultrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandUltrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification Demand
 
Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016
 
Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016
 
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DSIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
 
Ripley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation ToolsRipley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation Tools
 
RIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas DetectorRIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas Detector
 
Itron Fact Sheet
Itron Fact SheetItron Fact Sheet
Itron Fact Sheet
 
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
 
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetFiloform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
 

Recently uploaded

Nell’iperspazio con Rocket: il Framework Web di Rust!
Nell’iperspazio con Rocket: il Framework Web di Rust!Nell’iperspazio con Rocket: il Framework Web di Rust!
Nell’iperspazio con Rocket: il Framework Web di Rust!Commit University
 
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024BookNet Canada
 
Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024Scott Keck-Warren
 
Science&tech:THE INFORMATION AGE STS.pdf
Science&tech:THE INFORMATION AGE STS.pdfScience&tech:THE INFORMATION AGE STS.pdf
Science&tech:THE INFORMATION AGE STS.pdfjimielynbastida
 
Dev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio WebDev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio WebUiPathCommunity
 
Key Features Of Token Development (1).pptx
Key  Features Of Token  Development (1).pptxKey  Features Of Token  Development (1).pptx
Key Features Of Token Development (1).pptxLBM Solutions
 
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)Wonjun Hwang
 
Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Enterprise Knowledge
 
Pigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food ManufacturingPigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food ManufacturingPigging Solutions
 
CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):comworks
 
Connect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationConnect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationSlibray Presentation
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024Scott Keck-Warren
 
"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii SoldatenkoFwdays
 
SIP trunking in Janus @ Kamailio World 2024
SIP trunking in Janus @ Kamailio World 2024SIP trunking in Janus @ Kamailio World 2024
SIP trunking in Janus @ Kamailio World 2024Lorenzo Miniero
 
Bluetooth Controlled Car with Arduino.pdf
Bluetooth Controlled Car with Arduino.pdfBluetooth Controlled Car with Arduino.pdf
Bluetooth Controlled Car with Arduino.pdfngoud9212
 
Unleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubUnleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubKalema Edgar
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfAddepto
 
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Mark Simos
 

Recently uploaded (20)

Nell’iperspazio con Rocket: il Framework Web di Rust!
Nell’iperspazio con Rocket: il Framework Web di Rust!Nell’iperspazio con Rocket: il Framework Web di Rust!
Nell’iperspazio con Rocket: il Framework Web di Rust!
 
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
 
Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024
 
Science&tech:THE INFORMATION AGE STS.pdf
Science&tech:THE INFORMATION AGE STS.pdfScience&tech:THE INFORMATION AGE STS.pdf
Science&tech:THE INFORMATION AGE STS.pdf
 
Vulnerability_Management_GRC_by Sohang Sengupta.pptx
Vulnerability_Management_GRC_by Sohang Sengupta.pptxVulnerability_Management_GRC_by Sohang Sengupta.pptx
Vulnerability_Management_GRC_by Sohang Sengupta.pptx
 
Dev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio WebDev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio Web
 
Key Features Of Token Development (1).pptx
Key  Features Of Token  Development (1).pptxKey  Features Of Token  Development (1).pptx
Key Features Of Token Development (1).pptx
 
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
 
Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024
 
Pigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food ManufacturingPigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food Manufacturing
 
CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):
 
Connect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationConnect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck Presentation
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024
 
"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko
 
SIP trunking in Janus @ Kamailio World 2024
SIP trunking in Janus @ Kamailio World 2024SIP trunking in Janus @ Kamailio World 2024
SIP trunking in Janus @ Kamailio World 2024
 
Bluetooth Controlled Car with Arduino.pdf
Bluetooth Controlled Car with Arduino.pdfBluetooth Controlled Car with Arduino.pdf
Bluetooth Controlled Car with Arduino.pdf
 
Unleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubUnleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding Club
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdf
 
Hot Sexy call girls in Panjabi Bagh 🔝 9953056974 🔝 Delhi escort Service
Hot Sexy call girls in Panjabi Bagh 🔝 9953056974 🔝 Delhi escort ServiceHot Sexy call girls in Panjabi Bagh 🔝 9953056974 🔝 Delhi escort Service
Hot Sexy call girls in Panjabi Bagh 🔝 9953056974 🔝 Delhi escort Service
 
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
 

FEAM Lighting - Hazardous Area & Explosion Proof Lighting

  • 1. LIGHTING FIXTURES FOR FLUORESCENT TUBE LAMPS Explosion Proof Electrical Equipment EVF Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D LIGHTING FIXTURES ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIC T5/T4 DIP A21 TA (100…135)°C 1Ex d IIC T5/T4 DIP A21 TA (100…135)°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 ISSEP 02 ATEX 043 POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T5/T4 II 2 D Ex tD A21 T100°C / T135°C EXECUTION installation PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE EMERGENCY UNIT ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIC T6 DIP A21 TA T85°C 1Ex d IIC T6 DIP A21 TA T85°C ZONA 1 / 2 - ZONA 21 / 22 ZONA 1 / 2 - ZONA 21 / 22 ZONA 1 / 2 - ZONA 21 / 22 IP66 IP66 IP66 INERIS 08 ATEX 018 POCC IT. ГБ05.B02537 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-0; EN 61241-1; ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T6 II 2 D Ex d tD A21 T85°C EXECUTION installation PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body marine grade copper free aluminium (control gear & emergency unit) Tubes high-temperature resistant borosylicate glass tube painting external epoxy powders grey ral-9006 colour screws external stainless steel gaskets nbr rubber reflectors white stove enamelled sheet steel cable entry 3/4” npt size threaded Electrical characteristics power supply elettronic ballast 220v/240v - 50/60hz (p.f.corrected - cos ρ ≥ 0,98) lampholders bi-pin g13 cap internal wiring high-temperature resistant silicon rubber insulation cables emergency unit emergency unit composed of inverter charger and ni-cd battery pack 4A/h 6v. autonomy from 60 to 120min. Led power-on indicating lamp provided On Request Accessories: • Pole mounting kit complete with stainless steel hardware • Ceiling mounting kit complete with stainless steel hardware • Pendant mounting kit complete with stainless steel hardware • Wall/Structure mounting kit complete with stainless steel hardware • Galvanized steel wire protection guard • Stainless steel wire protection guard • Stainless steel reflectors • External painting colour on request • Electronic ballast with voltage supply different than standard • Ni-Cd Battery pack 7A/h 6V for Emergency Unit with Autonomy more than 150min Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 1 EVF Ex Lighting
  • 2. Ex Lighting EVF Technical data TEMPERATURE CLASS (GAS) LAMP EVF CODE TEMPERATURE CLASS (DUSTS) LAMPHOLDER CABLE ENTRY EMERGENCY UNIT AUTONOMY DETAIL FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 220V/240V - 50/60Hz T5 T4 T 100°C T 135°C G13 2 x 3/4” - - A T5 T4 T 100°C T 135°C G13 2 x 3/4” - - A T5 T4 T 100°C T 135°C G13 2 x 3/4” - - A T5 T4 T 100°C T 135°C G13 2 x 3/4” - - B T5 T4 T 100°C T 135°C G13 2 x 3/4” - - B T5 T4 T 100°C T 135°C G13 2 x 3/4” - - B EVF18EL 1 x 18W EVF36EL 1 x 36W EVF58EL 1 x 58W EVF18BEL 2 x 18W EVF36BEL 2 x 36W EVF58BEL 2 x 58W EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 220V/240V - 50/60Hz T5 T4 T 100°C G13 T 135°C 1 x 3/4” 4.8 V 1 x 1/2” 4Ah 2h C T5 T4 T 100°C G13 T 135°C 1 x 3/4” 1 x 1/2” 4.8 V - 4Ah 2h C T5 T4 T 100°C G13 T 135°C 1 x 3/4” 1 x 1/2” 4.8 V - 4Ah 2h C T5 T4 T 100°C G13 T 135°C 1 x 3/4” 1 x 1/2” 4.8 V - 4Ah 2h D T5 T4 T 100°C G13 T 135°C 1 x 3/4” 1 x 1/2” 4.8 V - 4Ah 2h D T5 T4 T 100°C G13 T 135°C 1 x 3/4” 1 x 1/2” 4.8 V - 4Ah 2h D EVF18ELME 1 x 18W EVF36ELME 1 x 36W EVF58ELME 1 x 58W EVF18ELBE 2 x 18W EVF36ELBE 2 x 36W EVF58ELBE 2 x 58W EVF Technical features A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL EVF18EL CODE 1000 96 95 602 4,50 2 x 3/4” A EVF36EL 1600 96 95 1202 5,70 2 x 3/4” A EVF58EL 1900 96 95 1490 7,00 2 x 3/4” A EVF18BEL 1000 200 95 602 9,00 2 x 3/4” B EVF36BEL 1600 200 95 1202 12,20 2 x 3/4” B EVF58BEL 1900 200 95 1490 14,70 2 x 3/4” B Reference details A A D 8MA C 8MA B 3/4” B A D 8MA B C 8MA 3/4” Since 1961 2 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 3. Ex Lighting EVF Technical features A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL 1000 222 379 602 10,00 1 x 3/4” / 1 x 1/2” C EVF36ELME 1600 222 379 1202 12,00 1 x 3/4” / 1 x 1/2” C EVF58ELME 1900 222 379 1490 14,00 1 x 3/4” / 1 x 1/2” EVF CODE EVF18ELME C EVF18ELBE 1000 287 265 602 16,00 1 x 3/4” / 1 x 1/2” D EVF36ELBE 1600 287 265 1202 19,00 1 x 3/4” / 1 x 1/2” D EVF58ELBE 1900 287 265 1490 21,00 1 x 3/4” / 1 x 1/2” D Reference details C A B 1 -1/2” C D 3/4” 3/4” D A B 3/4” D 3/4” C 1 -1/2” EVF Installation and mounting details Wall/structure mounting type 4 108 45 Pole mounting Assemblig detail with pole (typical) 3/4” 50 273 50 50 100 100 45° 8 12 45° 273 10 0 8 12 type 3 45 45 170 156 type 2 156 type 1 Pendant mounting 170 Ceiling mounting Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 3
  • 4. Ex Lighting EVF Polar diagrams – photometric data EVF EVF18BEL EVF36BEL EVF58BEL EVF On request accessories CODE GABBIAEVFF18 DESCRIPTION INSTALLATION 18W SIZE GALVANIZED STEEL WIRE PROTECTION GUARD MATERIAL GALVANIZED STEEL GABBIAEVFF36 36W SIZE GALVANIZED STEEL WIRE PROTECTION GUARD GALVANIZED STEEL GABBIAEVFF58 58W SIZE GALVANIZED STEEL WIRE PROTECTION GUARD GALVANIZED STEEL GABBIAEVFF18IX 18W SIZE STAINLESS STEEL WIRE PROTECTION GUARD STAINLESS STEEL GABBIAEVFF36IX 36W SIZE STAINLESS STEEL WIRE PROTECTION GUARD STAINLESS STEEL GABBIAEVFF58IX 58W SIZE STAINLESS STEEL WIRE PROTECTION GUARD STAINLESS STEEL D18IX 18W SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL D36IX 36W SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL D58IX 58W SIZE STAINLESS STEEL REFLECTOR 20301.0151 SINGLE LAMP CEILING MOUNTING KIT C/W HARDWARE STAINLESS STEEL TYPE 1 ALUM. LIGHT ALLOY 20301.0152 TWIN LAMP CEILING MOUNTING KIT C/W HARDWARE TYPE 1 ALUM. LIGHT ALLOY 20301.0153 SINGLE LAMP POLE MOUNTING KIT (SIZE 1” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0155 SINGLE LAMP POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0156 TWIN LAMP POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0157 SINGLE LAMP POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0158 TWIN LAMP POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20302.0128 SINGLE LAMP WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 GALVANIZED STEEL 20302.0128 TWIN LAMP WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 GALVANIZED STEEL 20301.0165 SINGLE LAMP PENDANT MOUNTING KIT C/W HARDWARE TYPE 2 GALVANIZED STEEL 20301.0165 TWIN LAMP PENDANT MOUNTING KIT C/W HARDWARE TYPE 2 GALVANIZED STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 4 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 5. LIGHTING FIXTURES FOR INCANDESCENT AND DISCHARGE LAMPS Explosion Proof Electrical Equipment EVAC Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D LIGHTING FIXTURE / CONTROL GEAR ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 01 ATEX 0054X POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T6/T2 II 2 D Ex tD A21 T80°C / T290°C EXECUTION installation PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body marine grade copper free aluminium (control gear & lamp body) Globe high-temperature resistant borosylicate glass painting external epoxy powders grey ral-9006 colour screws external stainless steel gaskets silicon rubber cable entry 3/4” npt size threaded Installation swivel bracket AISI 316L stainless steel Electrical characteristics Power supply (prc) conventional ballast 230V - 50Hz (p.f. corrected - cos ρ ≥ 0,95) Lampholders porcelain E27/E40 size Internal wiring high-temperature resistant silicon rubber insulation cables Terminals suitable up to 4mm/sq cables On Request Accessories: •Ceiling mounting AISI 316L stainless steel kit complete with stainless steel hardware •Pendant mounting AISI 316L stainless steel kit complete with stainless steel hardware •Pole mounting kit 1” – 1 1/2” – 2” dia. complete with stainless steel hardware •Wall/Structure mounting kit complete with stainless steel hardware •Galvanized steel wire protection guard •Stainless steel wire protection guard •White stove enamelled aluminium reflectors •Stainless steel reflectors •External painting colour on request •Control gear with voltage supply different than standard •Threaded cable entry different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 5 EVAC Ex Lighting
  • 6. Ex Lighting EVAC EVAC Technical data CODE TEMPERATURE CLASS (GAS) LAMP TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE CABLE ENTRY SIZE DETAIL LIGHTING FIXTURE FOR INCANDESCENT LAMP - POWER SUPPLY 230V-50Hz EVAC101 100 W EVAC100 100 W EVAC201 T4 T 130°C E-27 1 x 3/4" A T4 T 130°C E-27 2 x 3/4" B 200 W T4 T3 T 130°C T 195°C E-27 1 x 3/4" A EVAC200 200 W T4 T3 T 130°C T 195°C E-27 2 x 3/4" B EVAC301 300 W T4 T3 T 130°C T 195°C E-40 1 x 3/4" A EVAC300 300 W T4 T3 T 130°C T 195°C E-40 2 x 3/4" B EVAC501 500 W T3 T 195°C E-40 1 x 3/4" A EVAC500 500 W T3 T 195°C E-40 2 x 3/4" B EVAC100-E20 25 W 20 W T5 T4 T 95°C T 130°C E-14 + Ba-15s 2 x 3/4" B 1 x 3/4" A LIGHTING FIXTURE FOR HALOGEN LAMP - POWER SUPPLY 230V-50Hz EVAC101-100H 100 W T4 T 130°C E-27 EVAC100-100H 100 W EVAC201-150H 150 W T4 T 130°C E-27 2 x 3/4" B T1 T 130°C E-27 1 x 3/4" A EVAC200-150H 150 W T2 T 130°C E-27 2 x 3/4" B 250 W T4 T3 T 130°C T 195°C EVAC301-250H E-27 1 x 3/4" A EVAC300-250H 250 W T4 T3 T 130°C T 195°C E-27 2 x 3/4" B LIGHTING FIXTURE FOR HIGH PRESSURE MERCURY VAPOUR LAMP - POWER SUPPLY 230V-50Hz EVAC101-80HG 80 W T4 T 130°C E-27 2 x 3/4” / 1 x 1-1/2” C EVAC201-125HG 125 W T3 T 195°C E-27 2 x 3/4” / 1 x 1-1/2” C EVAC301-250HG 250 W T3 T 195°C E-40 2 x 3/4” / 1 x 1-1/2” C EVAC501-250HG 250 W T4 T 130°C E-40 2 x 3/4” / 1 x 1-1/2” C EVAC501-400HG 400 W T3 T 195°C E-40 2 x 3/4” / 1 x 1-1/2” C LIGHTING FIXTURE FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V-50Hz EVAC101-70HPNA 70 W T4 T 130°C E-27 2 x 3/4" / 1 x 1-1/2" C EVAC301-150HPNA 150 W T4 T 130°C E-40 2 x 3/4" / 1 x 1-1/2" C EVAC301-250HPNA 250 W T3 T2 T 195°C T 290°C E-40 2 x 3/4" / 1 x 1-1/2" C EVAC501-400HPNA 400 W T3 T 195°C E-40 2 x 3/4" / 1 x 1-1/2" C LIGHTING FIXTURE FOR METAL HALIDE LAMP - POWER SUPPLY 230V-50Hz EVAC101-100MH 100 W T4 T 130°C E-27 2 x 3/4" / 1 x 1-1/2" C EVAC301-150MH 150 W T4 T3 T 130°C T 195°C E-27 2 x 3/4" / 1 x 1-1/2" C EVAC301-250MH 250 W T3 T 195°C E-40 2 x 3/4" / 1 x 1-1/2" C EVAC501-400MH 400 W T3 T 195°C E-40 2 x 3/4" / 1 x 1-1/2" C LIGHTING FIXTURE FOR BLENDED LIGHT LAMP - POWER SUPPLY 230V-50Hz EVAC201-160MLL 160 W T3 T 195°C E-27 2 x 3/4" / 1 x 1-1/2" A EVAC200-160MLL 160 W T3 T 195°C E-27 2 x 3/4" / 1 x 1-1/2" B EVAC301-250MLL 250 W T3 T 195°C E-40 2 x 3/4" / 1 x 1-1/2" A EVAC300-250MLL 250 W T3 T 195°C E-40 2 x 3/4" / 1 x 1-1/2" B Since 1961 6 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 7. Ex Lighting EVAC Technical features CODE B [mm] C [mm] Ø D [mm] Ø E [mm] weight [Kg] CABLE ENTRY DETAIL 150 270 240 145 280 3,50 1 x 3/4” A EVAC100 150 270 240 145 280 3,50 2 x 3/4” B EVAC201 175 290 270 170 345 4,00 1 x 3/4” A EVAC200 175 290 270 170 345 4,00 2 x 3/4” B EVAC301 200 390 330 190 402 7,00 1 x 3/4” A EVAC300 200 390 330 190 402 7,00 2 x 3/4” B EVAC501 260 420 395 255 515 10,00 1 x 3/4” A EVAC500 260 420 395 255 515 10,00 2 x 3/4” B Reference details Reference details A B A 3/4” A 2X3/4” B Ø8 .5 60 60 16 80 C 80 60 C B 3 200 180 D E D E CODE A [mm] B [mm] C [mm] Ø D [mm] Ø E [mm] weight [Kg] CABLE ENTRY DETAIL 545 515 145 280 9,00 2 x 3/4” 1 x 1-1/2” C 2 x 3/4” 1 x 1-1/2” C 2 x 3/4” 1 x 1-1/2” C 2 x 3/4” 1 x 1-1/2” C EVAC101-..HG EVAC101-..HPNA 225 EVAC101-..MH EVAC201-..HG 225 565 545 170 345 9,50 EVAC301-..HG EVAC301-..HPNA 225 665 640 190 402 12,00 EVAC301-..MH EVAC501-..HG EVAC501-..HPNA 225 695 670 255 515 15,50 EVAC501-..MH Reference details C A 1-1/2” C B 200 5 30 28 28 0 Ø1 192 D E Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 7 EVAC A [mm] EVAC101
  • 8. Ex Lighting EVAC Installation and mounting details 237 16 type 1 Pendant mounting type 2 275 180 54 EVAC Ceiling mounting Wall/structure mounting type 3 283 58 Since 1961 8 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 9. Ex Lighting EVAC Installation and mounting details EVAC Pole mounting / Assemblig detail with pole (typical) SEALING FITTINGS SEALING FITTINGS POLE POLE 25° 25° EVAC Polar diagrams – photometric data EVAC125HG EVAC150HPS EVAC100MH Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 9
  • 10. Ex Lighting EVAC Polar diagrams – photometric data EVAC400HPS-D EVAC400MH-D EVAC EVAC250HG-D EVAC On request accessories CODE 20302.0070 DESCRIPTION INSTALLATION EVAC 100 / 101 SIZE STANDARD REFLECTOR MATERIAL WHITE STOVE ENAMELLED ALUMININIUM 20302.0071 EVAC 200 / 201 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUMININIUM 20302.0072 EVAC 300 / 301 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUMININIUM 20302.0073 EVAC 500 / 501 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUMININIUM 20302.0025 EVAC 100 / 101 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL 20302.0026 EVAC 200 / 201 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL 20302.0027 EVAC 300 / 301 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL 20302.0028 EVAC 500 / 501 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL 20302.0074 EVAC 100 / 101 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0075 EVAC 200 / 201 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0076 EVAC 300 / 301 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0077 EVAC 500 / 501 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0037 EVAC 100 / 101 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0038 EVAC 200 / 201 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0039 EVAC 300 / 301 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0040 EVAC 500 / 501 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0078 CEILING MOUNTING KIT C/W HARDWARE TYPE 1 AISI 316L STAINLESS STEEL 20302.0079 WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 AISI 316L STAINLESS STEEL 20302.0082 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 2 AISI 316L STAINLESS STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 10 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 11. LIGHTING FIXTURES FOR FLUORESCENT LAMPS Explosion Proof Electrical Equipment EVAC-FL Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D LIGHTING FIXTURE / CONTROL GEAR ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIC T6 X DIP A21 TA (80)°C 1Ex d IIC T6 X DIP A21 TA (80)°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 01 ATEX 0054X POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T6/T2 II 2 D Ex tD A21 T80°C / T290°C EXECUTION installation PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body marine grade copper free aluminium (control gear & lamp body) globe high-temperature resistant borosylicate glass painting external epoxy powders grey ral-9006 colour screws external stainless steel gaskets silicon rubber cable entry 3/4” npt size threaded Installation swivel bracket AISI 316L stainless steel Electrical characteristics Power supply (prc) elettronic ballast 220V/240V - 50/60Hz (p.f.corrected - cos ρ ≥ 0,98) lampholders porcelain e27 size - plastic 2g10 size internal wiring high-temperature resistant silicon rubber insulation cables terminals suitable up to 4mm/sq cables On Request Accessories: •Ceiling mounting AISI 316L stainless steel kit complete with stainless steel hardware •Pendant mounting AISI 316L stainless steel kit complete with stainless steel hardware •Pole mounting kit 1” – 1 1/2” – 2” dia. complete with stainless steel hardware •Wall/Structure mounting kit complete with stainless steel hardware •Galvanized steel wire protection guard •Threaded cable entry different than standard •Stainless steel wire protection guard •White stove enamelled aluminium reflectors •Stainless steel reflectors •External painting colour on request •Electronic ballast with voltage supply different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 11 EVAC-FL Ex Lighting
  • 12. Ex Lighting EVAC-FL EVAC-FL Technical data CODE TEMPERATURE CLASS (GAS) LAMP TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE CABLE ENTRY SIZE DETAIL LIGHTING FIXTURES FOR FLUORESCENT LAMPS - POWER SUPPLY 220V/240V - 50/60Hz EVAC101-15FL 1 x 15W T6 T 80°C E-27 1 x 3/4” A EVAC100-15FL 1 x 15W T6 T 80°C E-27 2 x 3/4” B EVAC201-23FL 1 x 23W T6 T 80°C E-27 1 x 3/4” A EVAC301-218FL 2 x 18W T6 T 80°C 2G-10 2 x 3/4” C EVAC301-318FL 3 x 18W T6 T 80°C 2G-10 2 x 3/4” C EVAC501-236FL 2 x 36W T6 T 80°C 2G-10 2 x 3/4” C EVAC501-336FL 3 x 36W T6 T 80°C 2G-10 2 x 3/4” C EVAC-FL Technical features CODE A [mm] B [mm] C [mm] Ø D [mm] Ø E [mm] EVAC101-15FL 150 270 235 145 280 weight [Kg] CABLE ENTRY 3,5 DETAIL 1 x 3/4” A 150 270 235 145 280 3,5 4 x 3/4” B 175 270 255 170 345 4 1 x 3/4” A EVAC301-218FL 225 180 605 590 190 395 12 2 x 3/4” EVAC301-318FL 225 605 590 190 395 12 2 x 3/4” C EVAC501-236FL 225 648 620 255 515 15,5 2 x 3/4” C EVAC501-336FL 225 620 255 515 15,5 2 x 3/4” 80 A .5 C ∅8 60 80 Reference details B A 3/4” 180 C 3 60 60 200 80 60 16 .5 60 ∅8 648 60 16 Reference details 200 3 80 EVAC100-15FL EVAC201-23FL A 2X3/4” B Ø8 .5 60 0 28 D E 60 16 80 192 28 Ø1 C 80 60 C B 3 200 180 Reference details D E 30 C A 1-1/2” 200 5 C B 200 5 30 28 28 0 Ø1 192 D E Since 1961 12 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 13. Ex Lighting EVAC-FL Installation and mounting details EVAC-FL Ceiling mounting 237 16 type 1 Pendant mounting 275 type 2 54 180 Wall/structure mounting type 3 283 58 Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 13
  • 14. Ex Lighting EVAC-FL EVAC-FL Installation and mounting details Pole mounting SEALING FITTINGS SEALING FITTINGS POLE POLE 25° 25° EVAC-FL On request accessories CODE DESCRIPTION INSTALLATION MATERIAL 20302.0070 EVAC 100 / 101 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM. 20302.0071 EVAC 200 / 201 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM. 20302.0072 EVAC 300 / 301 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM. 20302.0073 EVAC 500 / 501 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM. 20302.0025 EVAC 100 / 101 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL 20302.0026 EVAC 200 / 201 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL 20302.0027 EVAC 300 / 301 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL 20302.0028 EVAC 500 / 501 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL 20302.0074 EVAC 100 / 101 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0075 EVAC 200 / 201 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0076 EVAC 300 / 301 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0077 EVAC 500 / 501 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0037 EVAC 100 / 101 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0038 EVAC 200 / 201 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0039 EVAC 300 / 301 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0040 EVAC 500 / 501 SIZE STAINLESS STEEL PROTECTION GUARD 20302.0078 CEILING MOUNTING KIT C/W HARDWARE 20302.0079 WALL/STRUCTURE MOUNTING KIT C/W HARDWARE 20302.0082 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 1 TYPE 3 TYPE 2 STAINLESS STEEL AISI 316L STAINLESS STEEL AISI 316L STAINLESS STEEL AISI 316L STAINLESS STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 14 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 15. PORTABLE LIGHTING FIXTURES FOR INCANDESCENT LAMPS Explosion Proof Electrical Equipment EVP-100 Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D LIGHTING FIXTURE ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIC T4 (T5…T2) X DIP A21 TA (130)°C 1Ex d IIC T4 (T5…T2) X DIP A21 TA (130)°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 01 ATEX 0054X POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T4/T2 II 2 D Ex tD A21 T130°C EXECUTION installation PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body marine grade copper free aluminium (control gear & lamp body) Globe high-temperature resistant borosylicate glass Painting external epoxy powders grey ral-9006 colour Screws external stainless steel Gaskets silicon rubber Cable entry Nickel plated brass cable gland 1/2” npt (armoured cable) Electrical characteristics Power supply 12 ÷ 230V AC/DC lampholders e27 porcelain On Request Accessories: • External painting colour on request Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 15 EVP-100 Ex Lighting
  • 16. Ex Lighting EVP-100 EVP-100 Technical data CODE LAMP TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE CABLE ENTRY SIZE DETAIL LIGHTING FIXTURE FOR INCANDESCENT LAMP - POWER SUPPLY 230V-50Hz EVP-100 100 W T4 T 130°C E-27 CABLE GLAND 1/2” NPT A EVP-100 Technical features CODE A [mm] B [mm] C [mm] Ø D [mm] weight [Kg] CABLE ENTRY DETAIL 395 257 287 150 4,00 CABLE GLAND 1/2” NPT A EVP-100 Reference details B A A ØD C REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 16 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 17. AIRCRAFT WARNING LIGHTS AND A.W.L. CONTROL PANELS Explosion Proof Electrical Equipment AWL Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D OBSTRUCTION LIGHTING FIXTURE ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 01 ATEX 0054X POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIB+H2 T6…T3 DIP A21 TA 85°C ÷ 150°C 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C 1Ex d IIB+H2 T6…T3 DIP A21 TA 85°C ÷ 150°C 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 II 2 G Ex d IIC T6/T2 II 2 D Ex tD A21 T80°C / T290°C EXECUTION installation PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE CONTROL PANEL II 2 G Ex d IIB+H2 T6...T3 II 2 D Ex tD A21 T85°C ÷ T150°C II 2 G Ex d IIC T6/T2 II 2 D Ex tD A21 T80°C / T290°C EXECUTION PROTECTION DEGREE PROTEZIONE MECCANICA ICAO in according to icao directive ANNEX 14 EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0; EN 61241-1 RULES OF COMPLIANCE ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 Mechanical characteristics Body marine grade copper free aluminium globe high-temperature resistant borosylicate glass fresnel len shock proof acrilyc material suitable for high temperatures painting external epoxy powders grey ral-9006 colour screws external stainless steel gaskets silicon rubber cable entry 3/4” npt size threaded Electrical characteristics Lampholders porcelain e27 size internal wiring high-temperature resistant silicon rubber insulation cables terminals suitable up to 4mm/sq cables medium intensity flashing obstruction light 1450 / 2000 cd intensity (over than 45mt distance) low intensity steady obstruction light 30 cd intensity (less than 45mt distance) construction single awl - twin awl (1 main + 1 spare) in according to icao directive On Request Accessories: • Galvanized steel wire protection guard • External painting colour on request • Stainless steel wire protection guard • Threaded cable entry different than standard • Aircraft Warning Lights and control panel support manufactured in according to customer specification Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 17 AWL Ex Lighting
  • 18. Ex Lighting AWL Technical data AWL CODE LAMP TYPE TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) FLASHING [x/min.] LAMPHOLDER CABLE ENTRY SIZE DETAIL EVAC201-F 100W INCANDESCENT T4 T 130°C - E-27 1 x 3/4” A EVAC200-F 100W INCANDESCENT T4 T 130°C - E-27 4 x 3/4” A EVAC201-XF 6J XENOFLASH T6 T 80°C 65 ± 10 E-27 1 x 3/4” C EVAC200-XF 6J XENOFLASH T6 T 80°C 65 ± 10 E-27 4 x 3/4” C EVAC201-XFR-24V 6J XENOFLASH T6 T 80°C 65 ± 10 E-27 1 x 3/4” C EVAC201-F2R 2 x 100W INCAND. T4 T 130°C - E-27 1 x 3/4” B EVAC201-XF2R 2 x 6J XENOFLASH T6 T 80°C 65 ± 10 E-27 1 x 3/4” D EVAC301-25R 40W INCANDESCENT T4 T 130°C - E-27 1 x 3/4” C EVAC300-25R 40W INCANDESCENT T4 T 130°C - E-27 4 x 3/4” C AWL Technical features CODE EVAC201-F A [mm] B [mm] Ø C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL 415 200 - 4,50 1 x 3/4” A 430 EVAC200-F 430 415 200 - 4,50 4 x 3/4” A EVAC201-XF 280 260 176 - 4,50 1 x 3/4” C EVAC200-XF 280 260 176 - 4,00 4 x 3/4” C EVAC201-XFR-24V 280 260 176 - 4,00 1 x 3/4” C EVAC201-F2R 790 415 200 475 9,00 1 x 3/4” B EVAC201-XF2R 630 260 176 453 8,00 1 x 3/4” D EVAC301-25R 345 322 197 - 7,00 1 x 3/4” C EVAC300-25R 345 322 197 - 7,00 4 x 3/4” C Reference details A B D ØC ØC A A B B ØC 180 200 Since 1961 18 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 19. Ex Lighting AWL Technical features Reference details D AWL C D ØC ØC A A B B ØC 180 200 Aircraft warning lights models FRESNEL ROTALLARM XENOFLASH MULTI-LED Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 19
  • 20. Ex Lighting AWL AWL Control panels ex d INSTRUMENT HOUSING WITH PHOTOELECTRIC CELL >> 01 BREATHER VALVE TYPE ecd 02 03 AUT. ON MAN. OFF 04 05 ON OFF 12 07 06 ON OFF ON 13 08 15 10 ON OFF OFF 14 09 ON ON OFF OFF 16 11 ON ON OFF 17 OFF 18 19 Weatherproof Ip66 INSTRUMENT HOUSING WITH PHOTOELECTRIC CELL >> BREATHER VALVE TYPE ecde 02 01 03 AUT. ON MAN. OFF 04 05 06 07 EVAC On request accessories CODE DESCRIPTION MATERIAL 20302.0075 EVAC 200 / 201 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0076 EVAC 300 / 301 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0038 EVAC 200 / 201 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0039 EVAC 300 / 301 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0078 STRUCTURE MOUNTING KIT C/W HARDWARE 1030.00055 RED FRESNEL LEN Ø155mm PLASTIC 1030.00186 ORANGE FRESNEL LEN Ø155mm PLASTIC 1030.00211 GREEN FRESNEL LEN Ø155mm PLASTIC 1030.00213 WHITE FRESNEL LEN Ø155mm PLASTIC AISI 316L STAINLESS STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 20 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 21. MEdium intensity and loW intensity MULTILED System AIRCRAFT warning lights Ex Lighting Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) - Safe area Classification: Group II - Category 2G 2D MIOL - LIOL OBSTRUCTION WARNING LIGHTS ATEX 94/9/EC EXECUTION INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE INTERNATIONAL REGULATIONS COMPLIANCY FOR VISUAL AIDS GOST-R (RTR / RTN) ZONE 1 / 2 - ZONE 21 / 22 safe area 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C ZONE 1 / 2 - ZONE 21 / 22 safe area II 2 G Ex d IIC T6/T2 II 2 D Ex tD A21 T80°C / T290°C GOST-K 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C ZONE 1 / 2 - ZONE 21 / 22 safe area IP66 IP66 IP66 INERIS 01 ATEX 0054X POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 ICAO International Standards and Recommended Practices: Aerodromes - Annex 14 - Volume 1 - 4th Edition (November 2004) Charapter 6 : Medium Intensity Type B Flashing obstacle light MIOL-B Charapter 6 : Low Intensity Type A-B Steady burning obstacle light LIOL-A / LIOL-B FAA Advisor Circular AC150/5345-43F E.B.#67 - Lamp type MIOL-B / LIOL-A / LIOL-B Mechanical characteristics Body Painting Marine grade copper free aluminium High-temperature resistant borosylicate glass (zone 1/2 - 21/22 version) Transparent polycarbonate u/v resistant (safe area version) External epoxy powders grey ral-9006 colour Screws External stainless steel Gaskets Silicon rubber Cable Entry 3/4" Npt size threaded Globe Electrical characteristics Leds separate groups with individual led protection system - led technology stalilized by constant current generator Consumption LIOL-B = 4,8w (single and dual) / miol-B = 30w (single) - 60w (dual) Medium intensity (MIOL) flashing light with intensity 2000 cd (+/-25%) flashing 40 flash/minute Low intensity (LIOL) steady burning with intensity 32 cd (flashing on request) Realization single group leds system with own reflector dual groups leds system, each group with own reflector (1 main + 1 reserve) Optical characteristics Horizontal beam radiation 360° (miol / liol) Vertical beam radiation liol = between 5° and 10° / miol = 3° Efficency > 91% - pfc factor 0,99 Expetancy life long life time - more than 10 years Apply to: Flare - Airport - Stacks - High buildings - Chimneys - Tower crane - Pipelines - Bridges - Radio and Television towers Transmission lines - Wind turbines - Radar - and so on On request accessories: •Stainless steel wire protection guard •Aircraft Warning Lights and control panel support manufactured in according to customer specification •External painting colour on request •Threaded cable entry different than standard •Control panel with simultaneous or catenary multilight flashing system Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 21 MIOL - LIOL Explosion Proof Electrical Equipment
  • 22. MIOL - LIOL Ex Lighting MIOL - LIOL Technical data LED LAMP GROUP CODE VISUAL AIDS TYPES FLASHING [x/min.] EXECUTION TEMPERATURE TEMPERATURE CLASS (GAS) CLASS (DUSTS) CABLE ENTRIES DETAIL 1 x 3/4" B Low Intensity Obstruction warning lights LIOL-A-S > 10 cd x 1 LIOL-A-D RED FIXED > 10 cd x 2 LIOL-B-S RED FIXED > 32 cd x 1 LIOL-B-D RED FIXED > 32 cd x 2 RED FIXED Ex-d - T6 T80°C IP66 - - - 2 x 3/4" D Ex-d T6 T80°C 1 x 3/4" B IP66 - - - 2 x 3/4" D Ex-d T6 T80°C 1 x 3/4" B IP66 - 2 x 3/4" D T6 T80°C 1 x 3/4" B IP66 - - Ex-d - - 2 x 3/4" D MEDIUM Intensity Obstruction warning lights MIOL-A-S = 20.000 cd x 1 WHITE FLASHING 40 IP66 - - 2 x 3/4" C MIOL-A-D = 20.000 cd x 2 WHITE FLASHING 40 IP66 - - 2 x 3/4" C MIOL-B-S = 2.000 cd x 1 RED FLASHING 40 Ex-d T6 T80°C 1 x 3/4" A RED FLASHING = 2.000 cd x 2 MIOL-B-D = 2.000 cd x 1 MIOL-C-S MIOL-C-D RED FIXED = 2.000 cd x 2 RED FIXED IP66 40 - - 2 x 3/4" C Ex-d T6 T80°C 1 x 3/4" A IP66 - - - 2 x 3/4" C Ex-d T6 T80°C 1 x 3/4" A IP66 - 2 x 3/4" C T6 T80°C 1 x 3/4" A IP66 - - Ex-d - - 2 x 3/4" C MIOL - LIOL Technical features MIOL Reference details MIOL A MIOL 260 LIOL Reference details B LIOL LIOL T DO NO S SOTT O TE E IR 310 315 (FIXING) DO NO NOT N N O D SE GI NE ER IO EN ENS T NE RG DO NO NOT N IO W H IL E E N E ED NON AP R S N SOTT O TE E IR ED NON AP R 151 (FIXING) 768 O RG W H IL E E N E EN W SO HIL TT E O EN OP RIRE AP W SO HIL TT E O D SE GI NE ER IO EN ENS T T DO NO EN P EN OP RIRE AP IS NE P IS IO 445 150 115,5 (FIXING) 135,5 270 275 (FIXING) Since 1961 22 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 23. MIOL Reference details C MIOL LIOL MIOL - LIOL Technical features Reference details D MIOL 150 240 MIOL LIOL LIOL LIOL 660 200 410 191 320 400 MIOL - LIOL Main rules for aircraft warning lights MAIN RULES FOR VISUAL AIDS ICAO Annex 14 - Aerodromes Vol. 1 - Chapter 6 / 10 (July 2004) • The marking and/or lighting of obstacles is intended to reduce hazards to aircraft by indicating the presence of the obstacles (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.1) • Marking (red-orange/white painting) is used for day time • Marking may be ommitted when the obstacle is lighted • A fixed obstacle above a horizontal surface should be marked and, if the aerodrome is used at night, lighted.. (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.1.4) • A system of preventive maintenance of visual aids shall be employed to ensure lighting and marking system reliability (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 10.4.2) • The reliability of installed lighting equipments shold not less than one year (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 10.4.6) • The number and arrangement of Low, Medium or High Intensity Obstacle Lights , at each level to be marked, shall be such that the object is indicated from every angle in azimuth • Where a light is shielded in any direction by another, additional light shall be provided (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.22) • The number of lights needed for each level depends on the outside diameter of the obstacle • The top lights should be placed sufficiently below the top, so as to minimize contamination by smoke, powders, and so on.. (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.12) AWL TYPES (Aircraft Warning Lights) LIOL-A / B Low Intensity Obstacle Lights on fixed objects, Type-A / Type-B, shall be steady burning RED lights (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.23) MIOL-A Medium Intensity Obstacle Lights on fixed objects, Type-A , shall be flashing WHITE lights MIOL-B Medium Intensity Obstacle Lights on fixed objects, Type-B , shall be flashing RED lights MIOL-C Medium Intensity Obstacle Lights on fixed objects, Type-C , shall be steady burning RED lights (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.30) MIOL-A / MIOL-B Medium Intensity Obstacle Lights Type-A / Type-B, located on an obstacle, shall be flash simultaneously (ICA: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.32) HIOL-A / B High Intensity Obstacle Lights on fixed objects, Type-A / Type-B, shall be flashing WHITE lights (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.33) HIOL-A High Intensity Obstacle Lights Type-A, located on an obstacle, shall be flash simultaneously (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.35) HIOL-B High Intensity Obstacle Lights Type-B, indicating the presence of tower supporting overhead wires, an others.. shall be flash sequentially (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.36) Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 23 MIOL - LIOL Ex Lighting
  • 24. MIOL - LIOL Ex Lighting MIOL - LIOL Indicative diagram to obstruction light selection OBSTACLE ELEVATION > 45 m NO NO MARKED STRUCTURE (1) YES MARKED STRUCTURE (1) LIOL-A LIOL-B EXTENDED YES > 150 m VERTICAL STRUCTURE TYPE YES MIOL-B + LIOL-B MIOL-C NO YES LEGEND (1) DUAL MIOL-A/B MIOL-A DUAL MIOL-A/C DAY: HIOL-A + NIGHT: MIOL-B DAY: HIOL-A NIGHT: HIOL-A DAY: HIOL-A + NIGHT: MIOL-C DAY: MIOL-A + NIGHT: MIOL-B DAY: MIOL-A NIGHT: MIOL-A DAY: MIOL-A + NIGHT: MIOL-C Medium intensity obstruction light - TYPE A MIOL-B DUAL HIOL-A/C Low intensity obstruction light - TYPE B MIOL-A HIOL-A Low intensity obstruction light - TYPE A LIOL-B DUAL HIOL-A/B painted obstacle in acc. to icao directive LIOL-A NO Medium intensity obstruction light - TYPE B MIOL-C Medium intensity obstruction light - TYPE C HIOL-A High intensity obstruction light - TYPE A HIOL-B High intensity obstruction light - TYPE B MIOL - LIOL Polar diagrams – photometric data LIOL 32cd - Polar LIOL 32cd - CARTESIAN Flux 76.52 Im Maximum 69.78 cd Position H=-35.00 V=5.00 Efficiency: 100.00% MIOL 2000cd - Polar Flux 76.52 Im Maximum 69.78 cd Position H=-35.00 V=5.00 Efficiency: 100.00% Flux 1864.58 Im Maximum 4301.23 cd Position H=80.00 V=-90.00 Efficiency: 100.00% asymmetric VH asymmetric VH Flux 1864.58 Im Maximum 4301.23 cd Position H=80.00 V=-90.00 Efficiency: 100.00% asymmetric VH VH Planes VH Planes MIOL 2000cd - Cartesian VH Planes asymmetric VH VH Planes H Angles H Angles MIOL - LIOL On request accessories CODE DESCRIPTION MATERIAL 20302.0074 EVAC 100 / 101 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0077 EVAC 500 / 501 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0037 EVAC 100 / 101 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0040 EVAC 500 / 501 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL CONTROL PANEL WITH SIMULTANEOUS OR CATENARY MULTILIGHT FLASHING SYSTEM ALUMINIUM / PAINTED STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 24 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 25. FLOODLIGHTS FOR HALOGEN AND DISCHARGE LAMPS Explosion Proof Electrical Equipment SFDE Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D FLOODLIGHT / PROJECTOR ATEX 94/9/EC EXECUTION INSTALLATION GOST-K 1Ex de IIB T6 (T3…T2) DIP A21 TA (200…230) °C 1Ex de IIB T6 (T3…T2) DIP A21 TA (200…230) °C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 PROTECTION DEGREE ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 01 ATEX 0018 POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 CERTIFICATE REF. RULES OF COMPLIANCE GOST-R (RTR / RTN) II 2 G Ex d / Ex de IIB T3/T2 II 2 D Ex tD A21 T200°C / T229°C Mechanical characteristics Body marine grade copper free aluminium Diffuser tempered front glass support adjustable type hot dip galvanized steel reflector internal polished aluminium painting external epoxy powders grey ral-9006 colour screws external stainless steel gaskets silicon rubber cable entry 3/4” npt size threaded Electrical characteristics Power supply conventional ballast 230v - 50hz (p.f.corrected - cos ρ ≥ 0,95) lampholders porcelain e40 size internal wiring high-temperature resistant silicon rubber insulation cables terminals suitable up to 4mm/sq cables On Request Accessories: • External painting colour on request • Control gear with voltage supply different than standard • Threaded cable entry different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 25 SFDE Ex Lighting
  • 26. Ex Lighting SFDE Technical data POWER LAMP SFDE CODE TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE CABLE ENTRY SIZE DETAIL 2 x ISO-M20 A FLOODLIGHTS FOR HALOGEN LAMP - POWER SUPPLY 230V-50Hz SFDE500IA 500 W T2 T 229°C E-40 FLOODLIGHTS FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V-50Hz SFDE150HPNA 150 W T4 T 200°C E-40 2 x ISO-M20 A SFDE250HPNA 250 W T4 T 200°C E-40 2 x ISO-M20 A SFDE400HPNA 400 W T3 T 200°C E-40 2 x ISO-M20 A FLOODLIGHTS FOR METAL HALIDE LAMP - POWER SUPPLY 230V-50Hz SFDE250MH 250 W T4 SFDE400MH 400 W T3 T 200°C E-40 2 x ISO-M20 A T 200°C E-40 2 x ISO-M20 A SFDE Technical features CODE A [mm] B [mm] C [mm] D [mm] E [mm] SFDE150HPNA 485 425 290 270 504 F [mm] 88 WEIGHT [Kg] CABLE ENTRY 25,00 2 x ISO-M20 DETAIL A SFDE250HPNA 485 425 290 270 504 88 25,00 2 x ISO-M20 A SFDE400HPNA 485 425 290 270 504 88 25,00 2 x ISO-M20 A SFDE250MH 485 425 290 270 504 88 25,00 2 x ISO-M20 A SFDE400MH 485 425 290 270 504 88 25,00 2 x ISO-M20 A SFDE500 IA 485 425 290 270 504 88 21,00 2 x ISO-M20 A Reference details A F C E B D A 2 x ISOM20 2 x ISOM20 110 110 110 110 SFD250HPS SFD400MH SFD500IA REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 26 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 27. FLOODLIGHTS FOR INCANDESCENT AND DISCHARGE LAMPS Explosion Proof Electrical Equipment RCDE Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D FLOODLIGHT / PROJECTOR ATEX 94/9/EC EXECUTION GOST-R (RTR / RTN) GOST-K 1Ex d IIC T4/T3/T X DIP A21 TA 200°C, DIP A21 TA (135, 160, 200, 230)°C 1Ex d IIC T4/T3/T2 X DIP A21 TA (135, 160, 200, 230)°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 03 ATEX 0004 X POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T4/T3/T2 II 2 D Ex tD A21 T135°C/T160°C T200°C/T230°C INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE CONTROL GEAR ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 01 ATEX 0054X POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T6/T2 II 2 D Ex tD A21 T80°C/T290°C EXECUTION INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body marine grade copper free aluminium Diffuser tempered front glass Support adjustable type hot dip galvanized steel Reflector internal polished aluminium Painting external epoxy powders grey ral-9006 colour Screws external stainless steel Gaskets silicon rubber Cable entry 3/4” npt size threaded Electrical characteristics Power supply conventional ballast 230V - 50Hz (p.f.corrected - cos ρ ≥ 0,95) Lampholders porcelain E40 size Internal wiring high-temperature resistant silicon rubber insulation cables Terminals suitable up to 4mm/sq cables On Request Accessories: • External painting colour on request • Control gear with voltage supply different than standard • Threaded cable entry different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 27 RCDE Ex Lighting
  • 28. Ex Lighting RCDE Technical data TEMPERATURE CLASS (GAS) LAMP TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE CABLE ENTRY SIZE DETAIL 1x3/4” A 1x3/4” A FLOODLIGHTS FOR INCANDESCENT LAMP - POWER SUPPLY 230V-50Hz RECDE500 500 W T2 RECDE500 500 W T 230°C E-40 FLOODLIGHTS FOR BLENDED LIGHT LAMP - POWER SUPPLY 230V-50Hz T3 T 200°C E-40 FLOODLIGHTS FOR HIGH PRESSURE MERCURY VAPOUR LAMP - POWER SUPPLY 230V-50Hz RECDE500 250HG 250 W T3 T 160°C E-40 3x3/4” B RECDE500 400HG 400 W T3 T 200°C E-40 3x3/4” B FLOODLIGHTS FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V-50Hz RECDE500 250HPNA 250 W T4 RECDE500 400HPNA 400 W T3 T 135°C 3x3/4” B T 200°C E-40 E-40 3x3/4” B FLOODLIGHTS FOR METAL HALIDE LAMP - POWER SUPPLY 230V-50Hz RECDE500 250MH 250 W T4 T 135°C E-40 3x3/4” B RECDE500 400MH 400 W T3 T 200°C E-40 3x3/4” B WEIGHT [Kg] CABLE ENTRY DETAIL RCDE Technical features CODE A [mm] RECDE500 RECDE500 250HG 542 542 B [mm] C [mm] D [mm] 378 378 376 406 - 700 21,00 29,00 1 x 3/4” 3 x 3/4” A B RECDE500 250HPNA 542 378 406 700 29,50 3 x 3/4” B RECDE500 400HG 542 378 406 700 31,00 3 x 3/4” B RECDE500 400HPNA 542 378 406 700 31,50 3 x 3/4” B RECDE500 250MH 542 378 406 700 26,50 3 x 3/4” B RECDE500 400MH 542 378 406 700 31,50 3 x 3/4” B B 1x3/4” 1x3/4” 2x3/4” with PLG2 B A D A B A RCDE CODE C RCDE250MH 220 220 C RCDE250HG RCDE250HPS REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 28 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 29. Explosion Proof Electrical Equipment Ex Lighting EVO - EVT - TLF Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D PORTHOLE LIGHTING FIXTURE (EVO) ATEX 94/9/EC EXECUTION GOST-R (RTR / RTN) GOST-K 1Ex d IIC T3 X, DIP A21 TA 200°C 1Ex d IIC T3 X, DIP A21 TA 200°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 01 ATEX 0039 X POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T3, INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE II 2 D Ex tD A21 T200°C LIGHTING FIXTURE (EVT) ATEX 94/9/EC EXECUTION GOST-R (RTR / RTN) GOST-K 1Ex d IIC T4, DIP A21 TA 135°C 1Ex d IIC T4, DIP A21 TA 135°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 01 ATEX 0040 POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T4, INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE II 2 D Ex tD A21 T135°C LIGHTING FIXTURE (TLF) ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K II 2 G Ex d / Ex de IIB T3 II 2 D Ex tD A21 T200°C 1Ex d IIB T3, 2Ex de IIB T3 DIP A21 TA 200°C 1Ex d IIB T3, 2Ex de IIB T3 DIP A21 TA 200°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP65 IP65 IP65 INERIS 01 ATEX 0026 POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 EXECUTION INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body marine grade copper free aluminium diffuser borosilicate frontal glass (evt) diffuser tempered frontal glass (evo - tlf) painting external epoxy powders grey ral-9006 colour screws external stainless steel gaskets silicon rubber cable entry 3/4” npt size threaded protection guard galvanized wire steel (evt only) Electrical characteristics Power supply standard voltage 230v - 50hz lampholders porcelain e27 size internal wiring high-temperature resistant silicon rubber insulation cables On Request Accessories: • External painting colour on request • Threaded cable entry different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 29 EVO - EVT - TLF LIGHTING FIXTURES FOR INCANDESCENT LAMPS
  • 30. EVO – EVT - TLF Technical data CODE LAMP TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE CABLE ENTRY SIZE DETAIL LIGHTING FIXTURE FOR INCANDESCENT LAMP - POWER SUPPLY 230V-50Hz EVO100 100 W T3 EVT100 100 W T4 TLF100 100 W T3 T 200°C E-27 1x3/4” T135°C E-27 2x3/4” B T 200°C E-27 2x3/4” C A EVO – EVT - TLF Technical features CODE A [mm] B [mm] C [mm] WEIGHT [Kg] CABLE ENTRY DETAIL EVO100 Ø140 185 Ø162 2,00 1 x 3/4” A EVT100 Ø233 180 155 4,00 2 x 3/4” B TLF100 309 127 165 3,00 2 x 3/4” C Reference details 1 x 3/4” B Ø C A C 2 x 3/4” B B ØA A C A C 2 x 3/4” B EVO - EVT - TLF Ex Lighting REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 30 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 31. LIGHTING FIXTURES FOR HIGH EFFICENCY LED LAMPS AND FLUORESCENT TUBE LAMPS Explosion Proof Electrical Equipment EXL Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D LIGHTING FIXTURE ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIB T6, 1Exd [ia/ib] IIB T6, DIP A21 TA 85°C 1Ex d IIB T6, 1Exd [ia/ib] IIB T6, DIP A21 TA 85°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 IMQ 09 ATEX 020 POCC IT. ГБ05.B02537 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 ГОСТ Р 51330.9-99 (МЭК 660079-10-95) ГОСТ Р 51330.13-99 (МЭК 660079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIB T6 II 2 D Ex tD A21 T85°C EXECUTION INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body marine grade copper free aluminium Diffuser high-temperature resistant borosylicate glass painting external epoxy powders grey ral-9006 colour screws external stainless steel reflectors white stove enamelled sheet steel cable entry 3/4” npt size threaded c/w cable gland Electrical characteristics Power supply lampholders internal wiring elettronic ballast 220V/240V - 50/60Hz (p.f.corrected - cos ρ ≥ 0,98) bi-pin G5 cap (fluorescent lamp only) high-temperature resistant silicon rubber insulation cables terminals suitable up to 4mm/sq cables emergency unit emergency unit with inverter charger and Ni-Cd battery pack see technical features for more details Functional characteristics · EXL08ESA (Always ON - Maintained): 8W fluorescent lamp and electronic ballast 230V AC and emergency unit 3.6 V - 2Ah for an autonomy of 2 hours 3.6 V - 4Ah for an autonomy 3 hours · EXL08E (Emergency only - Maintained): 8W fluorescent lamp and emergency unit 3.6 V - 2Ah with autonomy 3 hours · EXL08L (Network only - Not Maintained): with high brightness LEDs (350mA - 4,8 W) Supply from 120V to 240V AC / DC · EXL08LE (Emergency only - Maintained): with high brightness LEDs (350mA - 4,8 W) 220/240V AC and emergency unit 6V - 2Ah for an autonomy of 3 hours complete with charge status monitor LED system (RED: battery under charging – GREEN: battery loaded) Remarks · EXL08E / EXL08ESA - 8W fluorescent lamp: emergency light intensity is 40% of light intensity with networking power supply · EXL08LE - with high brightness LEDs (350mA -4.8 W): emergency light intensity is 100% of light intensity with networking power supply On Request Accessories: • External painting colour on request • Electronic ballast with voltage supply different than standard • Threaded cable entry different than standard • Self-adhesive green label with EXIT sign (language on request) Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 31 EXL Ex Lighting
  • 32. Ex Lighting EXL Technical data POWER SUPPLY LAMP mA (LED) TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) EMERGENCY UNIT AUTONOMY LIGHTING FIXTURES FOR FLUORESCENT TUBE LAMPS EXL08 220 ÷ 240V AC 8W - T6 T 85°C - - EXL08E-3 220 ÷ 240V AC 8W - T6 T 85°C 3,6V - 4A/h 3h EXL08ESA-3 220 ÷ 240V AC 8W - T6 T 85°C 3,6V - 4A/h 3h EXL08L 120 ÷ 240V AC/DC 4,8 W 350 T6 T 85°C - - EXL08LE 220 ÷ 240V AC 4,8 W 350 T6 T 85°C 3,6V - 2A/h 3h EXL208L 120 ÷ 240V AC/DC 9,16 W 350 T6 T 85°C - - LIGHTING FIXTURES FOR HIGH EFFICENCY LED LAMPS EXL Technical features E [mm] WEIGHT [Kg] CABLE ENTRY DETAIL EXL08 CODE A [mm] 380 B [mm] 170 C [mm] 125 D [mm] 370 125 8,00 1 x 3/4” A EXL08E-3 380 170 125 370 125 8,00 1 x 3/4” A EXL08ESA-3 380 170 125 370 125 8,00 1 x 3/4” A EXL08L 380 170 125 370 125 8,00 1 x 3/4” A EXL08LE 380 170 125 370 125 8,00 1 x 3/4” A EXL208L 380 170 125 370 125 8,00 1 x 3/4” A Reference details A A C E B EXL CODE D 3/4" EXL On request accessories CODE DESCRIPTION EXL-08 MATERIAL SELF-ADHESIVE GREEN “EXIT” LABEL 2070.00088 POLYESTER EXL-08L EXL2-08L REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 32 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 33. LIGHTING FIXTURES FOR FLUORESCENT TUBE LAMPS Explosion Proof Electrical Equipment EVG Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D 18W LIGHTING FIXTURE ATEX 94/9/EC GOST-R (RTR / RTN) 2Ex edq IIC T4 (T6) DIP A21 TA 80°C II 2 G Ex edq IIC T4 II 2 D Ex tD A21 T 80°C EXECUTION AMBIENT TEMPERATURE 36W LIGHTING FIXTURE ATEX 94/9/EC II 2 G Ex edq IIC T4 II 2 D Ex tD A21 T 80°C -20°C ÷ +60°C -20°C ÷ +60°C IP66 IP66 IP66/64 PTB 97 ATEX 2223 POCC DE. ГБ05.B01788 PTB 07 ATEX 2040 EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 ГОСТ Р 51330.9-99 (МЭК 660079-10-95) ГОСТ Р 51330.13-99 (МЭК 660079-14-96) ГОСТ Р МЭК 61241-3-99 EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE LIGHTING FIXTURES WITH EMERGENCY UNIT ONLY 58W LIGHTING FIXTURE ATEX 94/9/EC GOST-R (RTR / RTN) II 2 G Ex edq IIC T4 II 2 D Ex tD A21 T 90°C EXECUTION AMBIENT TEMPERATURE -20°C ÷ +55°C 2Ex edq IIC T4 (T6) DIP A21 TA 90°C ATEX 94/9/EC II 2 GD Ex edq IIC T4 T80°C -20°C ÷ +60°C -20°C ÷ +60°C IP66 IP66 IP66/64 PTB 97 ATEX 2225 POCC DE. ГБ05.B01788 PTB 05 ATEX 2066 EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 ГОСТ Р 51330.9-99 (МЭК 660079-10-95) ГОСТ Р 51330.13-99 (МЭК 660079-14-96) ГОСТ Р МЭК 61241-3-99 EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE -20°C ÷ +55°C Mechanical characteristics Body glass fibre reinforced polyester resin diffuser u/v resistant polycarbonate - hinged to body safety closing operated by triangular key gaskets epdm rubber suitable for high temperatures and resistant to enviroments conditions internal reflector white polyester highly refractor diffuser cable entry iso-metric thread c/w plastic cable glands and stopping plug Electrical characteristics Power supply elettronic ballast 220v/240v - 50/60hz (p.f.corrected - cos ρ ≥ 0,98) lampholders bi-pin g13 cap internal wiring high-temperature resistant silicon rubber insulation cables terminals suitable up to 6mm/sq cables safety feature emergency unit “end of life” switching-off system in according to en 60079-7 rules emergency unit composed of inverter charger and ni-cd battery pack 7a/h 6v autonomy up to 180 min. advantages see table “advantage features” On Request Accessories: •Pole mounting kit complete with stainless steel hardware •Ceiling mounting kit complete with stainless steel hardware •Pendant mounting kit complete with stainless steel hardware •Wall/Structure mounting kit complete with stainless steel hardware •Electronic ballast with voltage supply different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 33 EVG Ex Lighting
  • 34. Ex Lighting EVG Technical data LAMP EVG CODE TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER CABLE ENTRY EMERGENCY UNIT AUTONOMY DETAIL FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50/60Hz SH-21EVG 1 x 18W T4 (Ta = -20°C / +60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 - - A SH-41EVG 1 x 36W T4 (Ta = -20°C / +60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 - - A SH-61EVG 1 x 58W T4 (Ta = -20°C / +60°C) T 90°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 - - A SH-22EVG 2 x 18W T4 (Ta = -20°C / +60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 - - A SH-42EVG 2 x 36W T4 (Ta = -20°C / +60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 - - A SH-62EVG 2 x 58W T4 (Ta = -20°C / +60°C) T 90°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 - - A EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50/60Hz SH-22EVG-E 2 x 18W T4 (Ta = -20°C / +60°C) T 80°C (Ta = -20°C / +60°C) G13 2 x ISO-M25 6 V - 7 A/h 3h B SH-42EVG-E 2 x 36W T4 (Ta = -20°C / +60°C) T 80°C (Ta = -20°C / +60°C) G13 2 x ISO-M25 6 V - 7 A/h 3h B EVG Technical features CODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL SH-21EVG 786 160 214 600 10,00 3 x ISO-M25 A SH-41EVG 1355 150 226 716 13,00 3 x ISO-M25 A SH-61EVG 1696 160 214 800 16,00 3 x ISO-M25 A SH-22EVG 786 160 214 600 10,50 3 x ISO-M25 A SH-42EVG 1355 150 226 716 13,50 3 x ISO-M25 A SH-62EVG 1696 160 214 800 16,50 3 x ISO-M25 A SH-22EVG-E 913 160 221 600 9,40 2 x ISO-M25 B SH-42EVG-E 1523 160 221 800 12,80 2 x ISO-M25 B Reference details A B D C A B B D C A Since 1961 34 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 35. Ex Lighting EVG Installation and mounting details type 1 type 2 Wall/structure mounting type 3 type 4 00 Pendant mounting EVG Ceiling mounting Pole mounting Assemblig detail with pole (typical) 1 50 100 45° EVG Polar diagrams – photometric data SH-21EVG SH-22EVG SH-41EVG Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 35
  • 36. Ex Lighting EVG Polar diagrams – photometric data SH-61EVG SH-62EVG EVG SH-42EVG EVG with emergency unit LIGHTING FIXTURES AND EMERGENCY UNIT ELECTRICAL DESIGN AND SPECIAL FEATURES Microprocessor (plc) “end-of life” switching-off system at the end of life a fluorescent tube lamp is safely switched off (according to iec en-60079-7 stds) Multi-function led multi-function led indcator with coded indication of the functions, status and potential failures of the electronic device and of the batteries Monitoring special signal whenever there is a e.o.l. situation (led red flashing ) automatic weekly functions test automatic annual 2/3 times operating period test function and operating period test can be done manually also Maintenance quick replacement of battery set even in explosive atmosphere presence electrical disconnection whenever the batteries box is opened 24h max recharging time (in according to en-60598-2-22) Safety Highest degree of safety in case of lamp failure during the emergency light operation In case of lamp failure during emergency operation the second tube lamp will automatically take over the emergency operation (two lamps version only) EVG On request accessories CODE DESCRIPTION INSTALLATION MATERIAL 20301.0162 POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0163 POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0165 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 2 STAINLESS STEEL 20302.0121 CEILING MOUNTING KIT C/W HARDWARE TYPE 1 GALVANIZED STEEL 20302.0128 WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 GALVANIZED STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 36 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 37. FLUORESCENT LIGHTING FIXTURES FOR CEILING OR RECESSED INSTALLATION Ex Lighting e191 - e192 Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D LIGHTING FIXTURE ATEX 94/9/EC II 2G Ex edq IIC T4 II 2D Ex tD A21 T 80°C EXECUTION AMBIENT TEMPERATURE GOST-R (RTR / RTN) 2Ex edq IIC T4, 2Ex eq II T4, DIP A21 TA 80°C -20°C ÷ +60°C (e191… - e192... surface/recessed in suspend. ceiling) -20°C ÷ +50°C (e191… recessed mount. insulated) -20°C ÷ +40°C (e192... recessed mount. insulated) PROTECTION DEGREE -20°C ÷ +40°C IP65 IP65 IBExU 04 ATEX 1062 POCC DE. ГБ05.B01788 EN 50014 +A1 +A2; EN 50017; EN 50018; EN 50019; EN 50281-1-1 ГОСТ Р 51330.9-99 (МЭК 660079-10-95) ГОСТ Р 51330.13-99 (МЭК 660079-14-96) ГОСТ Р МЭК 61241-3-99 CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body sheet steel white coloured ral 9016 diffuser safety toughened impact resistant tempered glass hinged to body safety closing central locking system operated by 5mm allen key - hinges on opposite side gaskets epdm rubber suitable for high temperatures and resistant to enviroments conditions internal reflector high anodized purest aluminium cable entry iso-metric thread c/w plastic cable glands and stopping plug Electrical characteristics Power supply dual channel elettronic ballast 220v/240v-50/60hz (p.f.corrected - cos ρ ≥ 0,98) - DC lampholders bi-pin g13 cap internal wiring high-temperature resistant silicon rubber insulation cables terminals suitable up to 6mm/sq cables isolating switch switching off all poles when lighting fitting is opened showing the actual position by optical indicator Safety feature “END OF LIFE” switching-off system in according to EN 60079-7 rules On Request Accessories: •Recessed mounting kit EB182 series complete with stainless steel hardware •Stainless steel sheet body •Electronic ballast with voltage supply different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 37 e191- e192 Explosion Proof Electrical Equipment
  • 38. e191 - e192 Technical data CODE TEMPERATURE CLASS (GAS) LAMP TEMPERATURE CLASS (DUSTS) LAMPHOLDER CABLE ENTRY DETAIL FLUORESCENT LIGHTING FIXTURES - POWER SUPPLY 220-240V-50/60Hz - DC e19121 1 x 18W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19122 2 x 18W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19141 1 x 36W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19142 2 x 36W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19161 1 x 58W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19162 2 x 58W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19223 3 x 18W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19224 4 x 18W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19243 3 x 36W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19244 4 x 36W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19263 3 x 58W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19264 4 x 58W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e191 - e192 Lighting fixture technical features CODE A [mm] B [mm] C [mm] D [mm] E [mm] WEIGHT [Kg] CABLE ENTRY DETAIL e19121 720 82 368 600 404 10,00 3 x ISO-M25 A e19122 720 82 368 600 404 10,00 3 x ISO-M25 A e19141 1330 82 368 1200 404 15,50 3 x ISO-M25 A e19142 1330 82 368 1200 404 15,50 3 x ISO-M25 A e19161 1630 82 368 1400 404 18,00 3 x ISO-M25 A e19162 1630 82 368 1400 404 18,00 3 x ISO-M25 A e19223 720 82 500 600 536 18,50 3 x ISO-M25 A e19224 720 82 500 600 536 18,50 3 x ISO-M25 A e19243 1330 82 500 1200 536 25,50 3 x ISO-M25 A e19244 1330 82 500 1200 536 25,50 3 x ISO-M25 A e19263 1630 82 500 1400 536 28,50 3 x ISO-M25 A e19264 1630 82 500 1400 536 28,50 3 x ISO-M25 A Lighting fixture Reference details A E Ø9 D B e191- e192 e192 e191- Ex Lighting C A Since 1961 38 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 39. e191 - e192 Recessed frame technical features CODE LUMINARIE TYPE EB182-18 e19121 388 740 786 93 300 434 82 9 e19122 388 740 786 93 300 434 82 9 EB182-36 e19141 388 1350 1396 98 400 434 82 9 e19142 388 1350 1396 98 400 434 82 9 e19161 388 1650 1696 48 400 434 82 9 EB182-58 A [mm] B [mm] C [mm] D [mm] E [mm] F [mm] G [mm] H [mm] e19162 388 1650 1696 48 400 434 82 9 EB192-18 e19223 520 740 786 93 300 566 82 9 e19224 520 740 786 93 300 566 82 9 EB192-36 e19243 520 1350 1396 96 400 566 82 9 e19244 520 1350 1396 96 400 566 82 9 EB192-58 e19263 520 1650 1696 48 400 566 82 9 e19264 520 1650 1696 48 400 566 82 9 Recessed frame Reference details B G A H F C D E E E D e191 - e192 Polar diagrams – photometric data e191-42 e192-43 e192-44 Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 39 e191- e192 Ex Lighting
  • 40. e191- e192 Ex Lighting e191 - e192 Polar diagrams – photometric data e191-22 e191-23 e191-64 e191 - e192 On request accessories CODE DESCRIPTION MATERIAL EB182-18 RECESSED FRAME FOR LIGHTING FIXTURE 1x18W AND 2x18W PAINTED SHEET STEEL EB182-36 RECESSED FRAME FOR LIGHTING FIXTURE 1x36W AND 2x36W PAINTED SHEET STEEL EB182-58 RECESSED FRAME FOR LIGHTING FIXTURE 1x58W AND 2x58W PAINTED SHEET STEEL EB192-18 RECESSED FRAME FOR LIGHTING FIXTURE 3x18W AND 4x18W PAINTED SHEET STEEL EB192-36 RECESSED FRAME FOR LIGHTING FIXTURE 3x36W AND 4x36W PAINTED SHEET STEEL EB192-58 RECESSED FRAME FOR LIGHTING FIXTURE 3x58W AND 4x58W PAINTED SHEET STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 40 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 41. INCREASED SAFETY LIGHTING FIXTURES FOR BI-PIN FLUORESCENT LAMPS Explosion Proof Electrical Equipment AVF Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D LIGHTING FIXTURE ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 2Ex ed IIC T5 DIP A21 TA 70°C 2Ex ed IIC T5 DIP A21 TA 70°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 KEMA 01 ATEX 2069 POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 60079-7; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex ed IIC T5 II 2 D Ex tD A21 T70°C EXECUTION INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE EMERGENCY UNIT ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex ed IIB T6 DIP A21 TA 85°C 1Ex ed IIB T6 DIP A21 TA 85°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 IMQ 08 ATEX 026X POCC IT. ГБ05.B02537 No. 07/43-269 EN 60070-0; EN 60079-7; EN 61241-0; EN 61241-1; ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex ed IIC T6 II 2 D Ex tD A21 T85°C EXECUTION INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body galss fibre reinforced polyester resin self-extinguishing acc. to UL94 Diffuser U/V resistant polycarbonate - hinged to body Safety closing operated by hexagonal key Gaskets EPDM 60 rubber suitable for high temperatures and resistant to enviroments conditions Internal reflector white stove enamelled sheet aluminum Cable entry ISO-Metric complete with cable glands and plug Electrical characteristics Power supply elettronic ballast 220V/240V 50/60Hz (p.f. corrected - cos ρ ≥ 0,98) Lampholders bi-pin G13 cap Internal wiring high-temperature resistant silicon rubber insulation cables Terminals suitable up to 6mm/sq cables Safety feature EEx de safety switch On Request Accessories: • Pole mounting kit complete with stainless steel hardware • Ceiling mounting kit complete with stainless steel hardware • Pendant mounting kit complete with stainless steel hardware • Wall/Structure mounting kit complete with stainless steel hardware • Electronic ballast with voltage supply different than standard • AUTOTEST electronic system for emergency unit Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 41 AVF Ex Lighting
  • 42. Ex Lighting AVF Technical data LAMP AVF CODE TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) CABLE ENTRY LAMPHOLDER EMERGENCY UNIT AUTONOMY DETAIL FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V 50/60Hz AVF 118 1 x 18W T5 T 70°C G13 3 x M20 x 1,5 - - A AVF 136 1 x 36W T5 T 70°C G13 3 x M20 x 1,5 - - A AVF 218 2 x 18W T5 T 70°C G13 3 x M20 x 1,5 - - A AVF 236 2 x 36W T5 T 70°C G13 3 x M20 x 1,5 - - A EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V 50/60Hz AVF 118-E 1 x 18W T5 T 70°C G13 2 x M20 x 1,5 4.8 V - 4Ah 3h B AVF 136-E 1 x 36W T5 T 70°C G13 2 x M20 x 1,5 4.8 V - 4Ah 3h B AVF 218-E 2 x 18W T5 T 70°C G13 2 x M20 x 1,5 4.8 V - 4Ah 3h B AVF 236-E 2 x 36W T5 T 70°C G13 2 x M20 x 1,5 4.8 V - 4Ah 3h B AVF Technical features A [mm] B [mm] WEIGHT [Kg] CABLE ENTRY DETAIL AVF 118 CODE 730 215 160 400 6,00 3 x M20 x 1,5 A AVF 136 1340 215 160 450 6,50 3 x M20 x 1,5 A AVF 218 730 215 160 400 7,00 3 x M20 x 1,5 A AVF 236 1340 215 160 450 7,50 3 x M20 x 1,5 A CODE C [mm] C [mm] D [mm] A [mm] B [mm] WEIGHT [Kg] CABLE ENTRY DETAIL AVF 118-E 925 215 280 D [mm] 400 11,00 2 x M20 x 1,5 B AVF 136-E 1535 215 280 450 11,50 2 x M20 x 1,5 B AVF 218-E 925 215 280 400 12,00 2 x M20 x 1,5 B AVF 236-E 1535 215 280 450 12,50 2 x M20 x 1,5 B Reference details A 8MA D 8MA C 8MA B B A 8MA D 8MA C 8MA B A Since 1961 42 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 43. Ex Lighting AVF Installation and mounting details Ceiling mounting Pendant mounting type 2 Wall/structure mounting type 3 type 4 0 10 AVF type 1 Pole mounting Assemblig detail with pole (typical) 50 100 45° AVF Polar diagrams – photometric data AVF218 AVF136 AVF236 Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 43
  • 44. Ex Lighting AVF with emergency unit (design and special features) AVF GENERALITY: The controller unit system permits to manage in AUTOTEST the verify of emergency unit working This system allows the emergency working of every fluorescent tube lamps (NON maintened working) The check and the control system has been realized by proper microprocessor which perform the following tests : - continuous test on the battery charger working, on the operation of the battery, and on presence of voltage supply - duration test in emergency working (every 3 months) with check of battery charge - test of emergency working (weekly) with check of right lamp operation Every information concerning the checks can be managed singly or tranmitted by “remote control system” in order to manage complete illumination system test in centralized way. Multicolor LED indicator in standard working (continuous led light) ON ON ON ON ON ON ON ON ON Regular operation ON ON ON ON ON ON ON ON ON Failed battery performance check OFF OFF OFF OFF OFF OFF OFF OFF OFF Lack of main power supply ON ON ON OFF ON ON ON OFF ON Lack of battery Multicolor LED indicator during test opetarion (intermittent led light) ON OFF ON OFF ON OFF ON OFF ON Performing lamp test ON ON OFF ON ON OFF ON ON OFF Performing battery pack test ON OFF ON OFF ON OFF ON OFF ON Failed lamp test Multicolor LED indicator during batteries recharging phase ON OFF ON OFF ON OFF ON OFF ON 24 hours ON ON ON ON ON ON ON ON ON After 24 hours AVF On request accessories CODE DESCRIPTION INSTALLATION MATERIAL 20301.0162 POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0163 POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0165 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 2 STAINLESS STEEL 20302.0121 CEILING MOUNTING KIT C/W HARDWARE TYPE 1 GALVANIZED STEEL 20302.0128 WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 GALVANIZED STEEL AUTOTEST electronic system - - REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 44 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 45. Explosion Proof Electrical Equipment Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D Ex Lighting SFDQL FLOODLIGHT ATEX 94/9/EC II 2G Ex eq II T3 II 2D Ex tD A21 T 200°C EXECUTION -40°C ÷ +40°C -40°C ÷ +60°C AMBIENT TEMPERATURE PROTECTION DEGREE IP66 CERTIFICATE REF. IMQ 09 ATEX 014X RULES OF COMPLIANCE EN 60079-0; EN 60079-5; EN 60079-7; EN 61241-0; EN 61241-1 Mechanical characteristics Body marine grade copper free aluminum Diffuser tempered front glass Support steel bracket with rotation-proof system Reflector anodized and polished 99,85 pure aluminum internal optic Painting thermosetting polyester powder resistant to atmospheric agents and corrosion grey RAL 9006 colour Screws stainless steel Gaskets pure silicon heat resistance Cable entry iso-Metric complete with nikel plated brass cable gland M20 Electrical characteristics Power supply 180 ÷ 230V DC / 180 ÷ 277V AC x 165W - 55W - 85W Lamp long life induction lamp (60.000 hours) Terminals suitable up to 4mm/sq cables On Request Accessories: •Power supply 90 ÷ 120V AC/DC (55/85W only) Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 45 SFDQL FLOODLIGHT PROJECTORS FOR INDUCTION LAMPS
  • 46. Ex Lighting SFDQL SFDQL Technical data CODE TEMPERATURE CLASS (GAS) LAMP TEMPERATURE CLASS (DUSTS) CABLE ENTRY SIZE DETAIL FLOODLIGHT FOR INDUCTION LAMP - POWER SUPPLY 220V/240V 50/60Hz - 220V/240V DC - 120V AC/DC SFDQL-55JB 55W T3 (Ta = -40°C / +60°C) T 200°C 2 x ISO M20 A SFDQL-85JB 85W T3 (Ta = -40°C / +60°C) T 200°C 2 x ISO M20 A SFDQL-55 55W T3 (Ta = -40°C / +60°C) T 200°C 1 x PCE M20 B SFDQL-85 85W T3 (Ta = -40°C / +60°C) T 200°C 1 x PCE M20 B FLOODLIGHT FOR INDUCTION LAMP - POWER SUPPLY 220V/240V 50/60Hz - 220V/240V DC SFDQL-165JB 165W T3 (Ta = -40°C / +40°C) T 200°C 2 x ISO M20 A SFDQL-165 165W T3 (Ta = -40°C / +40°C) T 200°C 1 x PCE M20 B WEIGHT [Kg] CABLE ENTRY DETAIL SFDQL Technical features CODE A [mm] B [mm] C [mm] D [mm] SFDQL-55JB 430 460 545 260 8,50 2 x ISO M20 A SFDQL-85JB 430 460 545 260 8,70 2 x ISO M20 A SFDQL-165JB 430 460 545 260 9,50 2 x ISO M20 A SFDQL-55 430 460 545 180 8,00 1 x PCE M20 B SFDQL-85 430 460 545 180 8,20 1 x PCE M20 B SFDQL-165 430 460 545 180 9,00 1 x PCE M20 B Reference details A A D II 2G Ex eq II T3 II 2D Ex tD A21 IP 66 T200° C IMQ 08 ATEX 014X www.feam-ex.com INDUCTION LAMP SFDQL C B 0722 55W 85W 165W 55W-85W Ta -40° C / +60° C 180÷230V DC 180÷277V AC 90÷120V AC/DC 165W Ta -40° C / +40° C 2 X ISO M20 0° 12 155 155 Since 1961 46 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 47. Ex Lighting Reference details B A D II 2G Ex eq II T3 II 2D Ex tD A21 IP 66 T200° C IMQ 08 ATEX 014X www.feam-ex.com INDUCTION LAMP SFDQL B 0722 C 55W 85W 165W 55W-85W Ta -40° C / +60° C 180÷230V DC 180÷277V AC 90÷120V AC/DC 165W Ta -40° C / +40° C 155 0° 12 1 X PCE M20 155 SFDQL Polar diagrams – photometric data SFDQL55 SFDQL85 SFDQL165 Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 47 SFDQL SFDQL Technical features
  • 48. Ex Lighting SFDQL SFDQL On request accessories CODE DESCRIPTION 20303.0099 PROTECTION GRID 20303.0100 MATERIAL POLE ADAPTER - DIA. 40÷60mm Protection grid 20303.0099 ALUMINUM PAINTED STEEL Pole adapter 20303.0100 REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 48 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 49. LIGHTING FIXTURES FOR FLUORESCENT TUBE LAMPS Explosion Proof Electrical Equipment EVSN Installation: hazardous areas - Zone 2 (Gases) - Zone 22 (Dusts) Classification: Group II - Category 3G 3D LIGHTING FIXTURE EMERGENCY UNIT ATEX 94/9/EC ATEX 94/9/EC II 2 G Ex ed IIC II 2 D Ex tD A21 T85°C II 3 G Ex nA II T6/T5 II 3 D Ex tD A22 T85°C/T100°C EXECUTION AMBIENT TEMPERATURE ZONE 2 - ZONE 22 INSTALLATION -40°C ÷ +55°C ZONE 1 / 2 - ZONE 21 / 22 PROTECTION DEGREE IP65 IP66 IMQ 08 ATEX 008X IMQ 08 ATEX 026X EN 60079-0; EN 60079-15; EN 61241-0; 61241-1 EN 60070-0; EN 60079-7; EN 61241-0; EN 61241-1 CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body glass fibre reinforced polyester resin Diffuser U/V resistant polycarbonate - hinged to body Safety closing stainless steel hooks with safety device Gaskets EPDM 60 rubber suitable for high temperatures and resistant to enviroments conditions Internal reflector white stove enamelled sheet steel Cable entry complete with PVC cable gland Electrical characteristics Power supply dual channel electronic ballast 220/240V 50/60Hz (cos ρ ≥ 0,98) Lampholders bi-pin G13 cap Terminals suitable up to 6mm/sq cables On Request Accessories: • Pole mounting kit complete with stainless steel hardware • Ceiling mounting kit complete with stainless steel hardware • Pendant mounting kit complete with stainless steel hardware • Wall/Structure mounting kit complete with stainless steel hardware • Electronic ballast with voltage supply different than standard • Ex-de safety switch • AUTOTEST electronic system for emergency unit Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 49 EVSN Ex Lighting
  • 50. Ex Lighting EVSN Technical data EVSN CODE LAMP TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER CABLE ENTRY WITH EMERGENCY CABLE GLAND UNIT AUTONOMY DETAIL FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50Hz T6 T 85°C EVSN118EL T5 T100°C T4 T135°C 1 x 18W T6 T5 T100°C 1 x PG 13,5 - - A 1 x PG 13,5 - - A T 85°C EVSN136EL G13 1 x 36W G1 T4 T135°C EVSN158EL T5 T100°C T6 T 85°C EVSN218EL T5 T100°C T4 T135°C 1 x 58W 2 x 18W T6 T5 T100°C 1 x PG 13,5 2 x 36W - - - A G13 1 x PG 13,5 G13 1 x PG 13,5 - - A G13 1 x PG 13,5 - - A T 85°C EVSN236EL G13 - A T4 T135°C EVSN258EL T5 T100°C 2 x 58W EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50Hz T6 T 85°C EVSNE118EL T5 T100°C T4 T135°C 1 x 18W T6 T5 4,8V - 4Ah 3h B G13 1 x PG 13,5 4,8V - 4Ah 3h B G13 1 x PG 13,5 4,8V - 4Ah 3h B G13 T100°C 1 x PG 13,5 1 x PG 13,5 4,8V - 4Ah 3h B 1 x PG 13,5 4,8V - 4Ah 3h B G13 1 x PG 13,5 4,8V - 4Ah 3h B D [mm] WEIGHT [Kg] T 85°C EVSNE136EL G13 1 x 36W T4 T135°C EVSNE158EL T5 T100°C 1 x 58W T6 T 85°C EVSNE218EL T5 T100°C T4 T135°C T6 T 85°C EVSNE236EL T5 T100°C 2 x 18W 2 x 36W G13 T4 T135°C T5 EVSNE258EL 2 x 58W T100°C EVSN Technical features CODE A [mm] B [mm] C [mm] CABLE ENTRY DETAIL EVSN118EL 667 90 98 420 1,75 1 x PG 13,5 A EVSN136EL 1276 90 98 775 2,45 1 x PG 13,5 A EVSN158EL 1576 90 98 1070 3,10 1 x PG 13,5 A EVSN218EL 667 155 102 455 2,10 1 x PG 13,5 A EVSN236EL 1276 155 102 770 3,90 1 x PG 13,5 A EVSN258EL 1576 155 102 1055 5,20 1 x PG 13,5 A Reference details D C A A B Since 1961 50 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 51. Ex Lighting EVSN Technical features CODE B [mm] C [mm] 842 90 120 EVSNE136EL 1451 90 EVSNE158EL 1751 90 EVSNE218EL 842 EVSNE236EL EVSNE258EL D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL 420 2,75 1 x PG 13,5 B 120 775 3,45 1 x PG 13,5 B 120 1070 4,10 1 x PG 13,5 B 155 120 455 3,10 1 x PG 13,5 B 1451 155 120 770 4,90 1 x PG 13,5 B 1751 155 120 1055 6,20 1 x PG 13,5 B Reference details B C D A B EVSN Installation and mounting details Ceiling mounting Pendant mounting type 1 type 2 Wall/structure mounting type 3 0 10 type 4 Pole mounting Assemblig detail with pole (typical) 50 100 45° Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 51 EVSN A [mm] EVSNE118EL
  • 52. Ex Lighting EVSN Polar diagrams – photometric data EVS136 EVS158 EVS218 EVS236 EVS258 EVSN EVS118 EVSN On request accessories CODE DESCRIPTION INSTALLATION MATERIAL 20302.0122 POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20302.0123 POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20302.0125 POLE MOUNTING KIT (SIZE 1” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0165 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 2 STAINLESS STEEL 20303.0091 CEILING MOUNTING KIT C/W HARDWARE TYPE 1 GALVANIZED STEEL 20303.0092 WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 GALVANIZED STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 52 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 53. FLOODLIGHTS FOR DISCHARGE LAMPS Explosion Proof Electrical Equipment Installation: hazardous areas - Zone 2 (Gases) - Zone 22 (Dusts) Classification: Group II - Category 3G 3D SFDN FLOODLIGHT ATEX 94/9/EC II 3 G Ex nR II T3 II 3 D Ex tD A22 T200°C EXECUTION AMBIENT TEMPERATURE -20°C ÷ +60°C PROTECTION DEGREE IP66 CERTIFICATE REF. IMQ 08 ATEX 019 RULES OF COMPLIANCE EN 60079-0; EN 60079-15; EN 61241-0; 61241-1 Mechanical characteristics Body marine grade copper free aluminum Diffuser tempered front glass Support steel bracket with rotation-proof system Reflector anodized and polished 99,85 pure aluminum internal optic Painting thermosetting polyester powder resistant to atmospheric agents and corrosion grey RAL 9006 colour Screws stainless steel Gaskets pure silicon heat resistance Cable entry complete with cable gland Internal optic (S) symmetric optic - (A)asymmetric optic - (C) concentrating beam optic Electrical characteristics Power supply conventional ballast 230V - 50Hz (P.F. CORRECTED - cos ρ ≥ 0,95) Lampholders porcellain E40 / E27 size Internal wiring high-temperature resistant silicon rubber insulation cables Terminals suitable up to 4mm/sq cables On Request Accessories: • Control gear with voltage supply different than standard • Threaded cable entry different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 53 SFDN Ex Lighting
  • 54. Ex Lighting SFDN SFDN Technical data CODE LAMP TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE CABLE ENTRY WITH CABLE GLAND DETAIL FLOODLIGHT FOR HIGH PRESSURE MERCURY VAPOUR LAMP - POWER SUPPLY 230V 50Hz SFDN#250HG-(1) 250 W T3 (Ta = -20°C / +60°C) T 200°C E-40 1 x PCE M20 A SFDN#400HG-(1) 400 W T3 (Ta = -20°C / +60°C) T 200°C E-40 1 x PCE M20 A FLOODLIGHT FOR METAL HALIDE LAMP - POWER SUPPLY 230V 50Hz SFDN#150MH-(1) 150 W T3 (Ta = -20°C / +60°C) T 200°C E-27 1 x PCE M20 A SFDN#250MH-(1) 250 W T3 (Ta = -20°C / +60°C) T 200°C E-40 1 x PCE M20 A SFDN#400MH-(1) 400 W T3 (Ta = -20°C / +60°C) T 200°C E-40 1 x PCE M20 A FLOODLIGHT FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V 50Hz SFDN#150HPNA-(1) 150 W T3 (Ta = -20°C / +60°C) T 200°C E-40 1 x PCE M20 A SFDN#250HPNA-(1) 250 W T3 (Ta = -20°C / +60°C) T 200°C E-40 1 x PCE M20 A SFDN#400HPNA-(1) 400 W T3 (Ta = -20°C / +60°C) T 200°C E-40 1 x PCE M20 A (1) INTERNAL OPTICAL BEAM: (S) SYMMETRIC BEAM - (A) ASYMMETRIC BEAM - (C) CONCENTRATING BEAM SAMPLE: SFDN#400MH-S = FLOODLIGHT 400W METAL HALIDE WITH SYMMETRIC OPTICAL BEAM SFDN Technical features CODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL SFDN#250HG-(1) 544 461 430 180 8,80 1 x PCE M20 A SFDN#400HG-(1) 544 461 430 180 9,10 1 x PCE M20 A SFDN#150MH-(1) 544 461 430 180 9,50 1 x PCE M20 A SFDN#250MH-(1) 544 461 430 180 9,70 1 x PCE M20 A SFDN#400MH-(1) 544 461 430 180 11,00 1 x PCE M20 A SFDN#150HPNA-(1) 544 461 430 180 10,50 1 x PCE M20 A SFDN#250HPNA-(1) 544 461 430 180 11,10 1 x PCE M20 A SFDN#400HPNA-(1) 544 461 430 180 12,30 1 x PCE M20 A (1) INTERNAL OPTICAL BEAM: (S) SYMMETRIC BEAM - (A) ASYMMETRIC BEAM - (C) CONCENTRATING BEAM SAMPLE: SFDN#400MH-S = FLOODLIGHT 400W METAL HALIDE WITH SYMMETRIC OPTICAL BEAM Since 1961 54 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 55. Ex Lighting Reference details A D C www.feam-ex.com FLOODLIGHT TYPE SFDN 150W HPNA 250W HPNA 400W HPNA 230V 50Hz 240V 50HZ SM AS CT 150W MH 250W MH 400W MH 220V 60Hz 277 60Hz B 0.206m˛ IK10 Ex nR II T3 Ex tD A22 IP 66 T200°C A II 3 GD IMQ 09 ATEX 019 Tamb -20° C / +60° C TOGLIERE TENSIONE PRIMA DI APRIRE DO NOT OPEN WHILE ENERGIZED 0° 12 155 155 SFDN Polar diagrams – photometric data SFDN#250HPNA-S SFDN#250HPNA-A SFDN#250HPNA-C Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 55 SFDN SFDN Technical features
  • 56. Ex Lighting SFDN SFDN Polar diagrams – photometric data SFDN#400MH-S SFDN#400MH-A SFDN#400MH-C SFDN On request accessories CODE DESCRIPTION 20303.0099 PROTECTION GRID 20303.0100 MATERIAL POLE ADAPTER FOR DIA 40÷60MM Protection grid 20303.0099 ALUMINIUM PAINTED STEEL Pole adapter 20303.0100 REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 56 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 57. Explosion Proof Electrical Equipment Weatherproof Lighting EVSA Installation: Safe Area Insulation Class: I LIGHTING FIXTURE CEI / EN EXECUTION INDUSTRIAL WEATHERPROOF AMBIENT TEMPERATURE - PROTECTION DEGREE IP65 CERTIFICATE REF. - RULES OF COMPLIANCE EN 60598-1 + A1; EN 60598-2-1 Mechanical characteristics Body glass fibre reinforced polyester resin Diffuser U/V resistant polycarbonate - hinged to body Safety closing stainless steel hooks Gaskets EPDM 60 rubber suitable for high temperatures and resistant to enviroments conditions Internal reflector white stove enamelled sheet steel Cable entry complete with PVC cable gland Electrical characteristics Power supply dual channel electronic ballast 220/240V 50/60Hz (cos ρ ≥ 0,98) Lampholders bi-pin G13 cap Terminals suitable up to 6mm/sq cables On Request Accessories: • Pole mounting kit complete with stainless steel hardware • Ceiling mounting kit complete with stainless steel hardware • Pendant mounting kit complete with stainless steel hardware • Wall/Structure mounting kit complete with stainless steel hardware • Electronic ballast with voltage supply different than standard • Emergency Group Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 57 EVSA WEATHERPROOF FLUORESCENT LIGHTING FIXTURES
  • 58. Weatherproof Lighting EVSA Technical data EVSA CODE TEMPERATURE CLASS (GAS) LAMP TEMPERATURE CLASS (DUSTS) LAMPHOLDER CABLE ENTRY WITH CABLE GLAND EMERGENCY UNIT AUTONOMY DETAIL FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50Hz EVSA118EL 1 x 18W - - G13 1 x PG 13,5 - - A EVSA136EL 1 x 36W - - G13 1 x PG 13,5 - - A EVSA158EL 1 x 58W - - G13 1 x PG 13,5 - - A EVSA218EL 2 x 18W - - G13 1 x PG 13,5 - - A EVSA236EL 2 x 36W - - G13 1 x PG 13,5 - - A EVSA258EL 2 x 58W - - G13 1 x PG 13,5 - - A EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50Hz EVSA118EL-E 1 x 18W - - G13 1 x PG 13,5 4,8V - 4Ah 3h A EVSA136EL-E 1 x 36W - - G13 1 x PG 13,5 4,8V - 4Ah 3h A EVSA158EL-E 1 x 58W - - G13 1 x PG 13,5 4,8V - 4Ah 3h A EVSA218EL-E 2 x 18W - - G13 1 x PG 13,5 4,8V - 4Ah 3h A EVSA236EL-E 2 x 36W - - G13 1 x PG 13,5 4,8V - 4Ah 3h A EVSA258EL-E 2 x 58W - - G13 1 x PG 13,5 4,8V - 4Ah 3h A EVSA Technical features CODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL EVSA118EL 667 90 98 420 1,75 1 x PG 13,5 A EVSA136EL 1276 90 98 775 2,45 1 x PG 13,5 A EVSA158EL 1576 90 98 1070 3,10 1 x PG 13,5 A EVSA218EL 667 155 102 455 2,10 1 x PG 13,5 A EVSA236EL 1276 155 102 770 3,90 1 x PG 13,5 A EVSA258EL 1576 155 102 1055 5,20 1 x PG 13,5 A A [mm] B [mm] C [mm] D [mm] CODE EVSA118EL-E 667 90 98 WEIGHT [Kg] CABLE ENTRY DETAIL 420 1,75 1 x PG 13,5 A EVSA136EL-E 1276 90 98 775 2,45 1 x PG 13,5 A EVSA158EL-E 1576 90 98 1070 3,10 1 x PG 13,5 A EVSA218EL-E 667 155 102 455 2,10 1 x PG 13,5 A EVSA236EL-E 1276 155 102 770 3,90 1 x PG 13,5 A EVSA258EL-E 1576 155 102 1055 5,20 1 x PG 13,5 A Reference details A C D A B Since 1961 58 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 59. Weatherproof Lighting EVSA Installation and mounting details Ceiling mounting Pendant mounting type 2 Wall/structure mounting type 3 type 4 00 EVSA type 1 Pole mounting Assemblig detail with pole (typical) 1 50 100 45° EVSA Polar diagrams – photometric data EVS118 EVS136 EVS158 Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 59
  • 60. Weatherproof Lighting EVSA Polar diagrams – photometric data EVS236 EVSA EVS218 EVS258 EVSA On request accessories CODE DESCRIPTION INSTALLATION MATERIAL 20302.0122 POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20302.0123 POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20302.0125 POLE MOUNTING KIT (SIZE 1” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0165 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 2 STAINLESS STEEL 20303.0091 CEILING MOUNTING KIT C/W HARDWARE TYPE 1 GALVANIZED STEEL 20303.0092 WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 GALVANIZED STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 60 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY